HomeMy WebLinkAboutLoad Calcs_50.pdf N.E.C.LOAD CALCULATION FOR DWELLING UNITS(STANDARD) BY: TMM DATE: 11/1/2016 PROJECT NAME: 5157 Gore Circle BUILDING: UNIT#: VOLTAGE: PHASE: ` ��‘\‘‘\ NN 5157 -- 240 1 000 Lict*I t o;eeM,TIN,..sFQ I LIGHTING&GENERAL RECEPTACLES: (NEC 220.12,via NEC 220.42) Uee.� a° 1 AREA(S.F.): VA/S.F. LOAD % •X-. Sc°.e l� 3,769 3 = 11307 VA 1 i° 47978 Ag SMALL APPLIANCES: (NEC 220.52(A)) di .p _a� Oa, 2 1500 = 3000 VA <<'.�j LAUNDRY CIRCUITS: (NEC 220.52(B)) {lit y' /, °' /,.e. . 1 1500 = 1500 VA '1.A.� ' ^ Ss 15807 VA LI A 16 First 3000VA 100% = 3000 VA a From 3001 to 120,000VA 35% = 4482 VA Over 120,000VA 25% = 0 VA 7482 VA x 100% = 7482 VA ELECTRIC COOKING APPLIANCES(3.5kW through 8.75kW): (NEC 220.55) Combination Oven 1 6800 VA = 6800 VA 0 0 VA = 0 VA 6800 VA x 80% = 5440 VA ELECTRIC COOKING APPLIANCES(over 8.75kW): (NEC 220.55) Cooktop(9600kVA) 1 8000 VA = 8000 VA 0 0 VA = 0 VA 8000 VA x 100% = 8000 VA ELECTRIC CLOTHES DRYERS: (NEC 220.54) Electric Dryer 1 5600 VA = 5600 VA 5600 VA x 100% = 5600 VA APPLIANCES: (NEC 220.53) APPLIANCE # LOAD TOTAL Hood 1 600 VA = 600 VA Dishwasher 1 800 VA = 800 VA Refrigerator/Freezer 1 1440 VA = 1440 VA Disposal 1 1176 VA = 1176 VA 0 0 VA = 0 VA 4016 VA x 75% = 3012 VA MECHANICAL EQUIPMENT: Boiler/Water Heater 2 1200 VA = 2400 VA Pumps 4 528 VA = 2112 VA 0 0 VA = 0 VA 4512 X 100% = 4512 VA MISCELLANEOUS EQUIPMENT: Hot Tub 0 10000 VA = 0 VA Steam Shower Large 1 9000 VA = 9000 VA Steam Shower Small 2 7500 VA = 15000 VA 24000 X 100% = 24000 VA TOTAL PRE-DEMAND ELECTRICAL LOAD: 68735 VA TOTAL DEMAND ELECTRICAL LOAD: 58046 VA MINIMUM ELECTRICAL SERVICE SIZE: 241.9 AMPS