Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
F15-0024_Cut Sheets Calcs_1430777700.pdf
CHATEAU d'OEX 3816 LUPINE DRIVE VAIL, COLORADO 81657 HYDRAULIC CALCULATIONS & PRODUCT SUBMITTALS THIS SET OF FIRE SPRINKLER SHOP SPE IFICATIONS AND HYDRAULIC CALCULATIONS HAVE BEEN REVIEWED AND FAO •• i 0 BE CCEPTABLE-N.LC.E.T.IV#102055 SR.ENGINEERING A0 TECHNI •• i -FI' ^ ' •• • TI P ,NATIONAL INSTITUTE FOR CERTIFICATION IN �GERING TECHNICIANS '-' 47/ �/ If -4-44717 -r%SET DATE PHOENIX AUTOMATIC SPRINKLER 7684 S. BRENTWOOD ST. LITTLETON, CO 80128 720.922.9231 PHONE CALCULATION SUMMARY Project Name:CHATEAU d'OEX Project Location: 3816 LUPINE DRIVE Drawing No. : City: VAIL, CO Design Areas Design Area Calc. Mode Occupancy Area of Total Water Pressure @ Min. Min. Min. Calculated Hose Margin To Name (Model) Application Source Density Pressure Flow Heads Streams Source up) (gpm) (psi) (gPm/tt2) (psi) (gpm) # (gpm) (Psi) 1 Demand (HW) DWELLING 1024 112.1 Req red 0.1 13.8 25.6 4 0 66 77 2 Demand (HW) DWELLING 900 106.6 Required 0.1 10.6 22.5 4 0 24.8 118.1 3 Demand (HW) DWELLING 900 99.6 Required 0.1 10.6 22.5 4 0 23.9 119.1 File:C:\dwg\Phoenix-Bersin\BerRes.dwg Date 4/8/2015 Copyright©2002-2012 Tyco Fire Protection Products Page 1 HYDRAULIC CALCULATIONS for Job Information Project Name:CHATEAU d'OEX Contract No. : City: VAIL, CO Project Location: 3816 LUPINE DRIVE Date: 12/30/1899 Contractor Information Name of Contractor: PHOENIX Address: 7684 SOUTH BRENTWOOD STREET City: LITTLETON, CO 80128 Phone Number: 303-523-2098 E-mail: Name of Designer: DLT Authority Having Jurisdiction: VAIL FIRE Design Remote Area Name 1 Remote Area Location BASEMENT GARAGE Occupancy Classification DWELLING Density(gpm/ft2) 0.1 Area of Application(ft2) 1024 Coverage per Sprinkler(ft2) 256 Number of Calculated Sprinklers 4 In-Rack Demand(gpm) 0 Special Heads Hose Streams(gpm) 0 Total Water Required(incl. Hose Streams)(gpm) 112.1 Required Pressure at Source(psi) 77 Type of System Wet Volume-Entire System (gal) 26.7 gal Water Supply Information Date March,2015 Location Near Site Source W1 Notes File:C:\dwg\Phoenix-Bersin\BerRes.dwg Date 4/8/2015 Copyright©2002-2012 Tyco Fire Protection Products Page 2 Job:CHATEAU d'OEX Hydraulic Analysis for : 1 Calculation Info Calculation Mode Demand Hydraulic Model Hazen-Williams Fluid Name Water @ 60F (15.6C) Fluid Weight, (Ib/ft3) N/A for Hazen-Williams calculation. Fluid Dynamic Viscosity, (Ib•s/ft2) N/A for Hazen-Williams calculation. Water Supply Parameters Supply 1 : W1 Flow(gpm) Pressure(psi) 0 143 1985 136 Hoses Inside Hose Flow/Standpipe Demand(gpm) Outside Hose Flow(gpm) Additional Outside Hose Flow(gpm) Other(custom defined) Hose Flow(gpm) Total Hose Flow(gpm) Sprinklers Ovehead Sprinkler Flow(gpm) 112.1 InRack Sprinkler Flow(gpm) 0 Other(custom defined)Sprinkler Flow(gpm) 0 Total Sprinkler Flow(gpm) 112.1 Other Required Margin of Safety(psi) 0 W1 -Pressure(psi) 77 W1 -Flow(gpm) 112.1 Demand w/o System Pump(s) N/A File:C:\dwg\Phoenix-Bersin\BerRes.dwg Date 4/8/2015 Copyright©2002-2012 Tyco Fire Protection Products Page 3 Job:CHATEAU d'OEX Hydraulic Analysis for : 1 f Supply f System Demand 1 15[ 11111--------- ' 135.231 140 -11---. __----------_— � ______ --- S� - -- -1 — 120_.. ---- 110- ---- — 100_..-- ---- — • 9 s _..--------- — _ 0. D2 —r.- — - i 80_ ; T-- N 70_ ------- — G2 - — --• __ ._ (7) 9 s ---- - — i - 0 iiiiismo mo ==mm.......�������� 0 60m0(B0®00100®100120013001400150016001700 1800 1900 2000 2100 Flow, gpm File:C:\dwg\Phoenix-Bersin\BerRes.dwg Date 4/8/2015 Copyright©2002-2012 Tyco Fire Protection Products Page 4 Job:CHATEAU d'OEX Hydraulic Analysis for : 1 Graph Labels Values Label Description Flow (gpm) Pressure (psi) S1 Supply point#1 -Static 0 143 S2 Supply point#2-Residual 1985 136 D1 Elevation Pressure 0 -1.1 D2 System Demand 112.1 77 Curve Intersections & Safety Margins Intersection Safety Margin Curve Name Pressure (psi) Flow (gpm) Pressure (psi) @ Flow (gpm) Supply 142.9 156.1 66 112.1 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/psi1/2) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) 101 Overhead 256 6.9 0.1 25.6 13.8 0.113 29 17.7 Sprinkler 102 Overhead 256 6.9 0.1 25.6 13.8 0.121 31 20.1 Sprinkler 103 Overhead 256 6.9 0.1 25.6 13.8 0.1 25.6 13.8 Sprinkler 104 Overhead 256 6.9 0.1 25.6 13.8 0.104 26.5 14.8 Sprinkler File:C:\dwg\Phoenix-Bersin\BerRes.dwg Date 4/8/2015 Copyright©2002-2012 Tyco Fire Protection Products Page 5 Job:CHATEAU d'OEX Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psi1/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 103 -1 6.9 25.6 1 lx(us.90)=3.82 0.5 150 13.8 077 -0.5 25.6 1.101 3.82 0.107 -0.2 4.32 0.5 077 -0.5 0 1 13 150 14 070 -0.5 25.6 1.055 0 0.1318 0 13 1.7 070 -0.5 26.5 1 1x(us.Tee-Br)=7.76 9.77 150 15.7 006 -0.5 52.1 1.055 7.76 0.492 0 17.53 8.6 006 -0.5 60 1.5 1x(coupling)=1.17 31.21 150 24.3 015-0 -2.54 112.1 1.527 2x(us.90)=9.34 10.5 0.3356 0.9 41.71 14 015-0 -2.54 0 1.5 0.78 0 39.3 Riser Manifold 015-I -3.32 112.1 0 0 4.0532 0.3 *** 0.78 3.2 015-I -3.32 0 1.5 1x(coupling)=1.17 1.92 150 42.8 016-0 -5.25 112.1 1.527 1.17 0.3356 0.8 3.09 1 016-0 -5.25 0 1.5 1.49 0 44.7 4000B DblChk 016-I -6.73 112.1 0 0 11.8813 0.6 *** 1.49 17.7 016-I -6.73 0 1.5 lx(coupling)=1.17 0.71 150 63.1 017-0 -7.45 112.1 1.527 1.17 0.3356 0.3 1.88 0.6 017-0 -7.45 0 2 0.63 0 64 RSV-1 017-I -8.07 112.1 0 0 3.696 0.3 *** 0.63 2.3 017-I -8.07 0 1.5 lx(coupling)=1.17 0.93 150 66.6 018 -9 112.1 1.527 1.17 0.3356 0.4 2.1 0.7 018 -9 0 2 3x(us.90)=17.44 123 150 67.8 W1 1.5 112.1 1.959 17.44 0.0997 -4.5 140.44 14 W1 77 Path No: 2 104 -1 6.9 26.5 1 lx(us.Tee-Br)=9.56 0.5 150 14.8 070 -0.5 26.5 1.101 9.56 0.1144 -0.2 10.06 1.2 070 15.7 File:C:\dwg\Phoenix-Bersin\BerRes.dwg Date 4/8/2015 Copyright©2002-2012 Tyco Fire Protection Products Page 6 Job:CHATEAU d'OEX Hydraulic Calculations PIPE INFORMATION Path No: 3 101 -1 6.9 29 1 1x(us.90)=3.82 0.75 150 17.7 110 -0.25 29 1.101 3.82 0.135 -0.3 4.57 0.6 110 -0.25 0 1 lx(us.Tee-Br)=7.76 8.25 150 18 088 -0.25 29 1.055 7.76 0.1662 0 16.01 2.7 088 -0.25 0 1 1x(us.90)=2 0.25 120 20.6 087 -0.5 29 1.049 2 0.2584 0.1 2.25 0.6 087 -0.5 0 1.5 4.75 150 21.3 001 -0.5 29 1.527 0 0.0275 0 4.75 0.1 001 -0.5 31 1.5 lx(us.90)=4.67 22.71 150 21.5 006 -0.5 60 1.527 4.67 0.1054 0 27.37 2.9 006 24.3 Path No: 4 102 -1 6.9 31 1 lx(us.Tee-Br)=9.56 0.5 150 20.1 001 -0.5 31 1.101 9.56 0.1523 -0.2 10.06 1.5 001 21.5 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 19.64 ft/s occurs in the following pipe(s): (015-0-006), (016-0-015-I), (017-0-016-I), (018-017-I) *** Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. File:C:\dwg\Phoenix-Bersin\BerRes.dwg Date 4/8/2015 Copyright©2002-2012 Tyco Fire Protection Products Page 7 Job:CHATEAU d'OEX Device Graphs Pressure vs. Flow Function Design Area: 1; Supply Ref.: W1; Supply Name:W1 160 150 140 130 1111111 120 110 ■■■■■■■ y 100 1111111 � 90 N 80 N 70 a 60 50 40 30 20 10 .■.■■■. 0 • •■ o o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 M v1 O t- 00 0 0 V1 00 Flow,gpm Pressure Loss Function Design Area: 1; BFP Ref.: 157 (4000B DblChk, Size = 1.5); Inlet Node: 016-I; Outlet Node: 016-0 19.9 18.9 17.7 psi @ 112.1 gpm 17.9 16.9- 15.9- .0/ 14.9 13.9 12.9 CA — — Q- 11.9 L 10.9" 7 " Cl _) 9.9 — L 8.9 CL 7.9 6.9" - 5.9 4.9 3.9- 2.9= 1.9= 0.9 o o 0 0 0 N 00 N Flow,gpm File:C:\dwg\Phoenix-Bersin\BerRes.dwg Date 4/8/2015 Copyright©2002-2012 Tyco Fire Protection Products Page 8 Job :CHATEAU d'OEX Device Graphs Pressure Loss Function Design Area: 1; Valve Ref.: 156 (RSV-1, Size = 2); Inlet Node: 017-I; Outlet Node: 017-0 2.3 psi @ 112.1 gpm 2.36 1.86 y a- d U) 1.36 y G) - L 0.86 0.36 • o .n en 0 0 0 0 0 0 0 0 0 0 0 0 0 0 In 0 0 — Cl M 7 In Flow,gpm Pressure Loss Function Design Area: 1; Valve Ref.: 158 (Riser Manifold, Size = 1.5); Inlet Node: 015-I; Outlet Node: 015-0 12.06 - — — 11.06 10.06 9.06 8.06 0_ 7.06 - tn 6.06 to d _ a 5.06 4.06 3.2 psi @ 112.1 gpm 3.06 • 2.06) 1.06 — 0.06 Nn C r Cl N Flow,gpm File:C:\dwg\Phoenix-Bersin\BerRes.dwg Date 4/8/2015 Copyright©2002-2012 Tyco Fire Protection Products Page 9 HYDRAULIC CALCULATIONS for Job Information Project Name:CHATEAU d'OEX Contract No. : City: VAIL, CO Project Location: 3816 LUPINE DRIVE Date: 12/30/1899 Contractor Information Name of Contractor: PHOENIX Address: 7684 SOUTH BRENTWOOD STREET City: LITTLETON, CO 80128 Phone Number: 303-523-2098 E-mail: Name of Designer: DLT Authority Having Jurisdiction: VAIL FIRE Design Remote Area Name 2 Remote Area Location LIVING HIGH CEILING Occupancy Classification DWELLING Density(gpm/ft2) 0.1 Area of Application(ft2) 900 Coverage per Sprinkler(ft2) 225 Number of Calculated Sprinklers 4 In-Rack Demand(gpm) 0 Special Heads Hose Streams(gpm) 0 Total Water Required(incl. Hose Streams)(gpm) 106.6 Required Pressure at Source(psi) 118.1 Type of System Wet Volume-Entire System (gal) 32.7 gal Water Supply Information Date March,2015 Location Near Site Source W1 Notes File:C:\dwg\Phoenix-Bersin\BerRes.dwg Date 4/8/2015 Copyright©2002-2012 Tyco Fire Protection Products Page 10 Job:CHATEAU d'OEX Hydraulic Analysis for : 2 Calculation Info Calculation Mode Demand Hydraulic Model Hazen-Williams Fluid Name Water @ 60F (15.6C) Fluid Weight, (Ib/ft3) N/A for Hazen-Williams calculation. Fluid Dynamic Viscosity, (Ib•s/ft2) N/A for Hazen-Williams calculation. Water Supply Parameters Supply 1 : W1 Flow(gpm) Pressure(psi) 0 143 1985 136 Hoses Inside Hose Flow/Standpipe Demand(gpm) Outside Hose Flow(gpm) Additional Outside Hose Flow(gpm) Other(custom defined) Hose Flow(gpm) Total Hose Flow(gpm) Sprinklers Ovehead Sprinkler Flow(gpm) 106.6 InRack Sprinkler Flow(gpm) 0 Other(custom defined)Sprinkler Flow(gpm) 0 Total Sprinkler Flow(gpm) 106.6 Other Required Margin of Safety(psi) 0 W1 -Pressure(psi) 118.1 W1 -Flow(gpm) 106.6 Demand w/o System Pump(s) N/A File:C:\dwg\Phoenix-Bersin\BerRes.dwg Date 4/8/2015 Copyright©2002-2012 Tyco Fire Protection Products Page 11 Job:CHATEAU d'OEX Hydraulic Analysis for : 2 f Supply f System Demand 1 15[ .--- - 140=II.....__---- — '-- ___ --- S� 135.231 13P -- D2 1-- — - — 120= 11------- 110- .------ — 100= ------- — 'y 90- ------ _ _ _ _ — -- i 80= ------- -- U) 70- -------- — CL 60= -------- -- -- 1 D1 - ----- _ - - -- - 0 0 60m0(B0®00100®100 2001300140015001600 1700 1800 1900 2000 2100 Flow, gpm File:C:\dwg\Phoenix-Bersin\BerRes.dwg Date 4/8/2015 Copyright©2002-2012 Tyco Fire Protection Products Page 12 Job:CHATEAU d'OEX Hydraulic Analysis for : 2 Graph Labels Values Label Description Flow (gpm) Pressure (psi) S1 Supply point#1 -Static 0 143 S2 Supply point#2-Residual 1985 136 D1 Elevation Pressure 0 3.4 D2 System Demand 106.6 118.1 Curve Intersections & Safety Margins Intersection Safety Margin Curve Name Pressure (psi) Flow (gpm) Pressure (psi) @ Flow (gpm) Supply 143 118.5 24.8 106.6 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/psi1/2) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) 201 Overhead 225 6.9 0.1 22.5 10.6 0.1 22.5 10.6 Sprinkler 202 Overhead 225 6.9 0.1 22.5 10.6 0.102 23 11.1 Sprinkler 203 Overhead 225 6.9 0.1 22.5 10.6 0.119 26.8 15.1 Sprinkler 204 Overhead 225 6.9 0.1 22.5 10.6 0.153 34.3 24.8 Sprinkler File:C:\dwg\Phoenix-Bersin\BerRes.dwg Date 4/8/2015 Copyright©2002-2012 Tyco Fire Protection Products Page 13 Job:CHATEAU d'OEX Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psi1/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 201 9 6.9 22.5 1 lx(us.90)=3.82 13 150 10.6 108 22 22.5 1.101 3.82 0.0843 -5.6 16.82 1.4 108 22 0 1 10 150 6.1 107 22 22.5 1.055 0 0.1038 0 10 1 107 22 23 1 12 150 7.1 106 22 45.5 1.055 0 0.3823 0 12 4.6 106 22 26.8 1 lx(us.Tee-Br)=7.76 6.69 150 11.7 105 22 72.3 1.055 7.76 0.9006 0 14.46 13 105 22 34.3 1.5 lx(us.90)=4.67 35.71 150 24.8 088 -0.25 106.6 1.527 2x(us.Tee-Br)=18.67 23.34 0.3056 9.6 59.05 18 088 -0.25 0 1 lx(us.90)=2 0.25 120 53 087 -0.5 106.6 1.049 2 2.8762 0.1 2.25 6.5 087 -0.5 0 1.5 lx(coupling)=1.17 58.67 150 59.6 015-0 -2.54 106.6 1.527 3x(us.90)=14 15.17 0.3056 0.9 73.84 22.6 015-0 -2.54 0 1.5 0.78 0 83.1 Riser Manifold 015-I -3.32 106.6 0 0 3.6918 0.3 *** 0.78 2.9 015-I -3.32 0 1.5 lx(coupling)=1.17 1.92 150 86.3 016-0 -5.25 106.6 1.527 1.17 0.3056 0.8 3.09 0.9 016-0 -5.25 0 1.5 1.49 0 88.1 4000B DblChk 016-I -6.73 106.6 0 0 11.3071 0.6 *** 1.49 16.8 016-I -6.73 0 1.5 lx(coupling)=1.17 0.71 150 105.6 017-0 -7.45 106.6 1.527 1.17 0.3056 0.3 1.88 0.6 017-0 -7.45 0 2 0.63 0 106.5 RSV-1 017-I -8.07 106.6 0 0 3.6536 0.3 *** 0.63 2.3 017-I -8.07 0 1.5 lx(coupling)=1.17 0.93 150 109.1 018 -9 106.6 1.527 1.17 0.3056 0.4 2.1 0.6 018 -9 0 2 3x(us.90)=17.44 123 150 110.2 W1 1.5 106.6 1.959 17.44 0.0908 -4.5 140.44 12.8 W1 118.1 Path No: 2 202 9 6.9 23 1 lx(us.Tee-Br)=9.56 13 150 11.1 107 22 23 1.101 9.56 0.0878 -5.6 22.56 2 107 7.1 File:C:\dwg\Phoenix-Bersin\BerRes.dwg Date 4/8/2015 Copyright©2002-2012 Tyco Fire Protection Products Page 14 Job:CHATEAU d'OEX Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psi1/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 3 203 9 6.9 26.8 1 lx(us.Tee-Br)=9.56 13 150 15.1 106 22 26.8 1.101 9.56 0.1163 -5.6 22.56 2.6 106 11.7 Path No: 4 204 9 6.9 34.3 1 lx(us.90)=3.82 13 150 24.8 109 22 34.3 1.101 3.82 0.1845 -5.6 16.82 3.1 109 22 0 1 lx(us.Tee-Br)=7.76 4.65 150 21.9 105 22 34.3 1.055 7.76 0.2271 0 12.41 2.8 105 24.8 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 39.58 ft/s occurs in the following pipe(s): (087-088) *** Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. File:C:\dwg\Phoenix-Bersin\BerRes.dwg Date 4/8/2015 Copyright©2002-2012 Tyco Fire Protection Products Page 15 Job:CHATEAU d'OEX Device Graphs Pressure vs. Flow Function Design Area: 2; Supply Ref.: W1; Supply Name:W1 160 150 140 130 1111111 120 110 ■■■■■■■ y 100 1111111 � 90 N 80 N 70 a 60 50 40 30 20 10 .■.■■■. 0 • •■ o o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 M v1 O t- 00 0 0 V1 00 Flow,gpm Pressure Loss Function Design Area: 2; BFP Ref.: 157 (4000B DblChk, Size = 1.5); Inlet Node: 016-I; Outlet Node: 016-0 19.9 18.9- 16.8 psi @106.6gpm - 17.9- 16.9- 15.9- 14.9- 13.9- CA 12.9- — — Q- 11.9 10.9" = �) 9.9 — UI 2 8.9 a 7.9" 6.9" - 5.9" 4.9. 3.9- 2.9= 1.9: 0.9: o o 0 0 0 N O Cl Flow,gpm File:C:\dwg\Phoenix-Bersin\BerRes.dwg Date 4/8/2015 Copyright©2002-2012 Tyco Fire Protection Products Page 16 Job :CHATEAU d'OEX Device Graphs Pressure Loss Function Design Area: 2; Valve Ref.: 156 (RSV-1, Size = 2); Inlet Node: 017-I; Outlet Node: 017-0 I 2.3 psi @ 106.6 gpm 2.36 • 1.86 y a- d U) 1.36 y G) - L 0.86 0.36 • • 0 0 0 0 0 0 0 0 0 0 - Cl M 7 In Flow,gpm Pressure Loss Function Design Area: 2; Valve Ref.: 158 (Riser Manifold, Size = 1.5); Inlet Node: 015-I; Outlet Node: 015-0 12.06 - L 11.06 10.06 9.06 fA 8.06 - 0_ 7.06 to 6.06 to G) - a 5.06 4.06 2.9 psi @ 106.6 gpm 3.06 2.06 1.06 0.06 N � n Flow,gpm File:C:\dwg\Phoenix-Bersin\BerRes.dwg Date 4/8/2015 Copyright©2002-2012 Tyco Fire Protection Products Page 17 HYDRAULIC CALCULATIONS for Job Information Project Name:CHATEAU d'OEX Contract No. : City: VAIL, CO Project Location: 3816 LUPINE DRIVE Date: 12/30/1899 Contractor Information Name of Contractor: PHOENIX Address: 7684 SOUTH BRENTWOOD STREET City: LITTLETON, CO 80128 Phone Number: 303-523-2098 E-mail: Name of Designer: DLT Authority Having Jurisdiction: VAIL FIRE Design Remote Area Name 3 Remote Area Location UPPER LEVEL BED RM Occupancy Classification DWELLING Density(gpm/ft2) 0.1 Area of Application(ft2) 900 Coverage per Sprinkler(ft2) 225 Number of Calculated Sprinklers 4 In-Rack Demand(gpm) 0 Special Heads Hose Streams(gpm) 0 Total Water Required(incl. Hose Streams)(gpm) 99.6 Required Pressure at Source(psi) 119.1 Type of System Wet Volume-Entire System (gal) 27 gal Water Supply Information Date March,2015 Location Near Site Source W1 Notes File:C:\dwg\Phoenix-Bersin\BerRes.dwg Date 4/8/2015 Copyright©2002-2012 Tyco Fire Protection Products Page 18 Job:CHATEAU d'OEX Hydraulic Analysis for : 3 Calculation Info Calculation Mode Demand Hydraulic Model Hazen-Williams Fluid Name Water @ 60F (15.6C) Fluid Weight, (Ib/ft3) N/A for Hazen-Williams calculation. Fluid Dynamic Viscosity, (Ib•s/ft2) N/A for Hazen-Williams calculation. Water Supply Parameters Supply 1 : W1 Flow(gpm) Pressure(psi) 0 143 1985 136 Hoses Inside Hose Flow/Standpipe Demand(gpm) Outside Hose Flow(gpm) Additional Outside Hose Flow(gpm) Other(custom defined) Hose Flow(gpm) Total Hose Flow(gpm) Sprinklers Ovehead Sprinkler Flow(gpm) 99.6 InRack Sprinkler Flow(gpm) 0 Other(custom defined)Sprinkler Flow(gpm) 0 Total Sprinkler Flow(gpm) 99.6 Other Required Margin of Safety(psi) 0 W1 -Pressure(psi) 119.1 W1 -Flow(gpm) 99.6 Demand w/o System Pump(s) N/A File:C:\dwg\Phoenix-Bersin\BerRes.dwg Date 4/8/2015 Copyright©2002-2012 Tyco Fire Protection Products Page 19 Job:CHATEAU d'OEX Hydraulic Analysis for : 3 f Supply f System Demand 1 15[ ---- - 140 -11---. __---- — '-- ___ --- S� 135.231 Z---1 13- D2- --- — 120=1- ---- 110- ---- — 100_ ------- — 'y 90---------- _ _ _ _ — -- i= - r.- 80_ -------- -- U) 70_ -------- _ 0_ 60:..--________ 0_..--------- -- -- 24,---- - . . _ . . _ _ ._ . . 0_,uIIIMME AMM ---------- 0 60m0(B0®00100®100 2001300140015001600 1700 1800 1900 2000 2100 Flow, gpm File:C:\dwg\Phoenix-Bersin\BerRes.dwg Date 4/8/2015 Copyright©2002-2012 Tyco Fire Protection Products Page 20 Job:CHATEAU d'OEX Hydraulic Analysis for : 3 Graph Labels Values Label Description Flow (gpm) Pressure (psi) S1 Supply point#1 -Static 0 143 S2 Supply point#2-Residual 1985 136 D1 Elevation Pressure 0 8 D2 System Demand 99.6 119.1 Curve Intersections & Safety Margins Intersection Safety Margin Curve Name Pressure (psi) Flow (gpm) Pressure (psi) @ Flow (gpm) Supply 143 110.6 23.9 99.6 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/psi1/2) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) 301 Overhead 225 6.9 0.1 22.5 10.6 0.1 22.5 10.6 Sprinkler 302 Overhead 225 6.9 0.1 22.5 10.6 0.101 22.8 10.9 Sprinkler 303 Overhead 225 6.9 0.1 22.5 10.6 0.119 26.8 15.1 Sprinkler 304 Overhead 225 6.9 0.1 22.5 10.6 0.122 27.4 15.8 Sprinkler File:C:\dwg\Phoenix-Bersin\BerRes.dwg Date 4/8/2015 Copyright©2002-2012 Tyco Fire Protection Products Page 21 Job:CHATEAU d'OEX Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psi1/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 301 19 6.9 22.5 1 lx(us.90)=2.49 1 120 10.6 041 20 22.5 1.097 2.49 0.1297 -0.4 3.49 0.5 041 20 0 1 lx(us.90)=3.11 4.38 150 10.6 039 20 22.5 1.055 3.11 0.1038 0 7.48 0.8 039 20 22.8 1 1x(us.Tee-Br)=7.76 6.71 150 11.4 038 20 45.3 1.055 7.76 0.379 0 14.47 5.5 038 20 26.8 1.25 1x(us.90)=3.27 2.5 150 16.9 033 19.5 72.1 1.291 3.27 0.3357 0.2 5.77 1.9 033 19.5 27.4 1.25 3x(us.Tee-Br)=19.64 53.79 150 19.1 008 -0.5 99.6 1.291 2x(us.90)=6.55 26.19 0.61 8.7 79.98 48.8 008 -0.5 0 1.5 1x(coupling)=1.17 23.48 150 77 015-0 -2.54 99.6 1.527 2x(us.90)=9.34 10.5 0.2693 0.9 33.98 9.2 015-0 -2.54 0 1.5 0.78 0 87.1 Riser Manifold 015-I -3.32 99.6 0 0 3.2533 0.3 *** 0.78 2.5 015-I -3.32 0 1.5 lx(coupling)=1.17 1.92 150 90 016-0 -5.25 99.6 1.527 1.17 0.2693 0.8 3.09 0.8 016-0 -5.25 0 1.5 1.49 0 91.7 4000B DblChk 016-I -6.73 99.6 0 0 10.671 0.6 *** 1.49 15.9 016-I -6.73 0 1.5 1x(coupling)=1.17 0.71 150 108.3 017-0 -7.45 99.6 1.527 1.17 0.2693 0.3 1.88 0.5 017-0 -7.45 0 2 0.63 0 109.1 RSV-1 017-I -8.07 99.6 0 0 3.5965 0.3 *** 0.63 2.2 017-I -8.07 0 1.5 1x(coupling)=1.17 0.93 150 111.6 018 -9 99.6 1.527 1.17 0.2693 0.4 2.1 0.6 018 -9 0 2 3x(us.90)=17.44 123 150 112.6 W1 1.5 99.6 1.959 17.44 0.08 -4.5 140.44 11.2 W1 119.1 Path No: 2 302 19 6.9 22.8 1 lx(us.Tee-Br)=6.22 1 120 10.9 039 20 22.8 1.097 6.22 0.1327 -0.4 7.22 1 039 11.4 File:C:\dwg\Phoenix-Bersin\BerRes.dwg Date 4/8/2015 Copyright©2002-2012 Tyco Fire Protection Products Page 22 Job:CHATEAU d'OEX Hydraulic Calculations PIPE INFORMATION Path No: 3 303 19 6.9 26.8 1 1x(us.90)=2.49 1 120 15.1 042 20 26.8 1.097 2.49 0.1798 -0.4 3.49 0.6 042 20 0 1 lx(us.Tee-Br)=7.76 3.29 150 15.3 038 20 26.8 1.055 7.76 0.1438 0 11.06 1.6 038 16.9 Path No: 4 304 19 6.9 27.4 1 lx(us.90)=2.49 0.5 120 15.8 036 19.5 27.4 1.097 2.49 0.1874 -0.2 2.99 0.6 036 19.5 0 1 1x(us.Tee-Br)=7.76 8.03 150 16.2 065 19.5 27.4 1.055 7.76 0.1499 0 15.8 2.4 065 19.5 0 1.25 1x(us.Tee-Br)=6.55 2.95 150 18.5 033 19.5 27.4 1.291 6.55 0.0561 0 9.5 0.5 033 19.1 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 24.4 ft/s occurs in the following pipe(s): (008-033) *** Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. File:C:\dwg\Phoenix-Bersin\BerRes.dwg Date 4/8/2015 Copyright©2002-2012 Tyco Fire Protection Products Page 23 Job:CHATEAU d'OEX Device Graphs Pressure vs. Flow Function Design Area: 3; Supply Ref.: W1; Supply Name:W1 160 150 140 130 1111111 120 110 •■•■■■■ .y 100 1111111 � 90 80 N 70 O. 60 50 40 30 20 10 MENU..- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 M v1 O l� 00 T O V1 0 Flow,gpm Pressure Loss Function Design Area: 3; BFP Ref.: 157 (4000B DblChk, Size = 1.5); Inlet Node: 016-I; Outlet Node: 016-0 19.9- 18.9_ / 17.9: 15.9 psi @ 99.6 gpml' 16.9- 15.9 — 14.9- ._-- 13.9- — — CA 12.9: — — Q- 11.9- 0 10.9" 7 " Ch 9.9_— cn L 8.9 CL 7.9" 6.9" - 5.9" 4.9= 3.9- 2.9: 1.9= 0.9= 0 0 0 0 0 N O Cl Flow,gpm File:C:\dwg\Phoenix-Bersin\BerRes.dwg Date 4/8/2015 Copyright©2002-2012 Tyco Fire Protection Products Page 24 Job :CHATEAU d'OEX Device Graphs Pressure Loss Function Design Area: 3; Valve Ref.: 156 (RSV-1, Size = 2); Inlet Node: 017-I; Outlet Node: 017-0 2.2 psi @ 99.6 gpm 2.36 Y 1.86 y a- d U) 1.36 y G) - L 0.86 0.36 • 0 0 0 0 0 0 0 0 0 0 - Cl M 7 In Flow,gpm Pressure Loss Function Design Area: 3; Valve Ref.: 158 (Riser Manifold, Size = 1.5); Inlet Node: 015-I; Outlet Node: 015-0 12.06 - — 11.06 10.06 9.06 fA 8.06 - 0_ 7.06 - tn 6.06 to G) - a 5.06 4.06 2.5 psi @ 99.6 gpm 3.06 2.06 1.06 0.06 n Flow,gpm File:C:\dwg\Phoenix-Bersin\BerRes.dwg Date 4/8/2015 Copyright©2002-2012 Tyco Fire Protection Products Page 25 WATER FLOW TEST REPORT PROJECT NAME: BERSIN RES JOB# HYDRANT# &LOCATION: Near Site DATE: 1/3/1900 TEST BY: PAS Day or Week: MARCH TIME OF DAY: Noon MIN. OF FLOW: WATER SUPPLIED BY: Rangeview MW PURPOSE OF TEST: FIRE FLOW DATA FLOW HYDRANT(S) Al A2 A3 SIZE OPENING: 2.5 0 COEFFICIENT: 0.9 0 PITOT READING: 140 0 GPM: 1985 0 0 TOTAL FLOW DURING TEST: 1985 GPM STATIC READING: 153 PSI RESIDUAL: 146 PSI RESULTS: AT 20 PSI RESIDUAL 9736 GPM AT 0 PSI 050 GPM ESTIMATED CONSUMPTION: 1985 GAL. REMARKS: 150 - 140 130 120 110 100 •y 90 a m 80 y 70 m a 60 50 40 30 20 10 0 , 0 500 1000 1500 2000 2500 3000 3500 4000 Flow,gpm VicoWorldwide Fire Protection Contacts www.tyco-fire.com Products RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Pendent Wet Pipe and Dry Pipe Systems General Escutcheon reduces the accuracy to which the pipe drops to the sprinklers Description must be cut. The Series LFII Residential Sprinklers The TYCO RAPID RESPONSE have been designed with heat sensi- . `___,. Series LFII Residential Pendent tivity and water distribution charac- ir irr. and Recessed Pendent Sprinklers teristics proven to help in the control (TY2234) are decorative, fast of residential fires and to improve the response, frangible bulb sprinklers chance for occupants to escape or be designed for use in residential occu- evacuated. pancies such as homes, apart- f ments, dormitories, and hotels. When Dry Pipe System Application -- aesthetics and optimized flow charac- The Series LFII Residential Pendent teristics are the major consideration, and Recessed Pendent Sprinklers the Series LFII Residential Sprinklers offers a laboratory approved option S rinkler (TY2234)should be the first choice. for designing dry pipe residential p sprinkler systems, whereas, most The Series LFII Residential Sprinklers residential sprinklers are laboratory Identification are intended for use in the following approved for wet systems only. scenarios: Number (SIN) Through extensive testing, it has been • wet and dry pipe residential sprin- determined that the number of design TY2234 kler systems for one-and two-family sprinklers (hydraulic design area)for dwellings and mobile homes per the Series LFII Residential Pendent NFPA 13D and Recessed Pendent Sprinklers Technical • wet and dry pipe residential sprin- (TY2234) need not be increased kler systems for residential occu- over the number of design sprinklers Data pancies up to and including four (hydraulic design area) as specified stories in height per NFPA 13R for wet pipe sprinkler systems, as is Approvals accustomed for density/area sprinkler UL Listed for use with wet pipe and • wet and dry pipe sprinkler systems systems designed per NFPA 13. dry pipe systems for the residential portions of any Consequently, the Series LFII C-UL Listed for use only with wet pipe occupancy per NFPA 13 Residential Sprinklers offer the systems The recessed version of the Series features of non-water filled pipe in NSF Certified to NSF/ANSI 61 LFII Residential Sprinklers is intended addition to not having to increase the for use in areas with finished ceilings. number of design sprinklers(hydraulic For details on these approvals, refer It employs a two-piece Style 20 design area)for systems designed to to the Design Criteria section. Recessed Escutcheon.The Recessed NFPA 13, 13D, or 13R. Escutcheon provides 1/4 inch(6,4 mm) Maximum Working Pressure of recessed adjustment or up to 1/2 NOTICE 175 psi (12,1 bar) inch (12,7 mm) of total adjustment Discharge Coefficient from the flush ceiling position. The The Series LFII Residential Pendent and K—4.9 GPM/psi1/2 (70,6 LPM/bar1/2) adjustment provided by the Recessed Recessed Pendent Sprinklers(TY2234) described herein must be installed and Temperature Rating maintained in compliance with this 155°F(68°C)or 175°F(79°C) document and the applicable stan- IMPORTANT dards of the National Fire Protection Finishes Always refer to Technical Data Association, in addition to the stan- Natural Brass Sheet TFP700 for the "INSTALLER dards of any authorities having jurisdic- Pure or Signal White WARNING" that provides cautions tion. Failure to do so may impair the Chrome Plated with respect to handling and instal- performance of these devices. Physical Characteristics lation of sprinkler systems and The owner is responsible for main- Frame Brass components. Improper handling and taining their fireprotection system and Button Sealing Assembly Copper Beryllium can permanentlydamage devices inprer operatin condi- Nickel w/TEFLON a sprinkler system or its components tion. Contact the installing contractor Bulb(3 mm) Glass and cause the sprinkler to fail to or sprinkler manufacturer with Compression Screw Bronze operate in a fire situation or cause it any questions. Deflector Bronze to operate prematurely. Ejection Spring Stainless Steel Page 1 of 6 FEBRUARY 2014 TFP400 TFP400 Page 2 of 6 7/16"(11,1 mm) ESCUTCHEON 1/2" Components: NOMINAL NPT PLATE SEATING 2-7/8" DIA. 1 Frame MAKE-IN SURFACE (73,0 mm) 2 - Button 3 Sealing Assembly 1 _ 4 Bulb 5 Compression 2 : 1 Screw 2-1/4"6 Deflector* INLs �� � if ((57,2 mm) wM �® 4 1 / Oil1-5/8" STYLE 20 41,3 mm) WRENCH RECESSED , 5 -- mFLATS Temperature � � ■ Of ESCUTCHEON rating is indicated on Deflector. CROSS SECTION PENDENT RECESSED PENDENT FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS(TY2234) 2-7/8" DIA. es (73,0 mm) 7/16±1/8" 1/2"(12,7 mm) _ (11,1±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) WRENCH RECESS FACE OF --n— (57,2 mm) ~ (END "A" USED SPRINKLER MOUNTING FOR TY2234) FITTING PLATE FIGURE 3 1mW-TYPE 6 V/ � �Ua I SPRINKLER WRENCH MOUNTING WRENCH SURFACE IN 1/8" RECESS (3,2 mm) 1-3/8" (34,9 mm) CLOSURE TY2234 1-1/8" (28,6 mm) FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE RAPID RESPONSE SERIES LFII RESIDENTIAL PENDENT SPRINKLER (TY2234) PUSH WRENCH IN TO ENSURE Operation Residential Sprinkler Design Guide ENGAGEMENT N When conditions exist that are WITH SPRINKLER The glass bulb contains a fluid that outside the scope of the provided WRENCHING AREA expands when exposed to heat.When criteria, refer to the Residential FIGURE 4 the rated temperature is reached, the Sprinkler Design Guide TFP490 for W-TYPE 7 RECESSED fluid expands sufficiently to shatter the the manufacturer's recommendations SPRINKLER WRENCH glass bulb, allowing the sprinkler to that may be acceptable to the local activate and flow water. authority having jurisdiction. Ceiling Types S stem T es Smooth flat horizontal, or beamed, or Y yp sloped, in accordance with the 2013 Design Per the UL Listing, wet pipe and dry Edition of NFPA 13D, 13R, or 13 as pipe systems may be utilized. Per the applicable. Criteria C-UL Listing, only wet pipe systems may be utilized. Hydraulic Design The TYCO RAPID RESPONSE Refer to Technical Data Sheet TFP485 (NFPA 13D and 13R) Series LFII Residential Pendent for the use of residential sprinklers in For systems designed to NFPA and Recessed Pendent Sprinklers residential drypipe systems. 13D or NFPA 13R, the minimum (TY2234)are UL and C-UL Listed for p p y installation in accordance with this required sprinkler flow rates are section. TFP4OO Page 3 of 6 given in Tables A and B as a func- InstallationStep C. Tighten the sprinkler into the tion of temperature rating and the sprinkler fitting using only the W-Type 7 maximum allowable coverage areas. The TYCO RAPID RESPONSE Recessed Sprinkler Wrench (Figure 4). The sprinkler flow rate is the minimum Series LFII Residential Pendent With reference to Figure 1, apply the required discharge from each of the and Recessed Pendent Sprinklers W-Type 7 Recessed Sprinkler Wrench total number of"design sprinklers"as (TY2234) must be installed in accor to the sprinkler wrench flats. specified in NFPA 13D or NFPA 13R. The number of "design sprinklers" dance with this section: Step D. After the ceiling has been specified in NFPA 13D and 13R for wet installed or the finish coat has been pipe systems is to be applied when General Instructions applied, slide on the Style 20 Closure designing dry pipe systems. Do not install any bulb type sprin- over the Series LFII Residential kler if the bulb is cracked or there is a Sprinkler and push the Closure over the Hydraulic Design loss of liquid from the bulb. With the Mounting Plate until its flange comes in (NFPA 13) sprinkler held horizontally, a small air contact with the ceiling. For systems designed to NFPA 13, bubble should be present. The diam- the number of design sprinklers is eter of the air bubble is approximately to be the four most hydraulically 1/16 inch (1,6 mm). demanding sprinklers. The minimum A leak-tight 1/2 inch NPT sprinkler required discharge from each of the joint should be obtained by applying four sprinklers is to be the greater of the following: a minimum-to-maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher • The flow rates given in Tables A levels of torque can distort the sprin- or B as a function of temperature kler Inlet with consequent leakage or rating and the maximum allowable impairment of the sprinkler. coverage area. Do not attempt to compensate • A minimum discharge of 0.1 gpm/ft2 for insufficient adjustment in an over the "design area" comprised Escutcheon Plate by under- or over- of the four most hydraulically tightening the sprinkler. Re-adjust the demanding sprinklers for actual position of the sprinkler fitting to suit. coverage areas protected by the four sprinklers. Series LFII Residential Pendent Sprinklers The number of "design sprinklers" The Series LFII Residential Pendent specified in NFPA 13 for wet pipe Sprinklers must be installed in accor- systems is to be applied when dance with the following instructions. designing dry pipe systems. Step 1. Install pendent sprinklers in Dry Pipe System Water Delivery the pendent position with the deflector When using the Series LFII Residential parallel to the ceiling. Sprinklers(TY2234) in dry pipe sprin- Step 2. With pipe thread sealant klersystems, the time for water applied to the pipe threads, hand- delivery must not exceed 15 seconds tighten the sprinkler into the sprinkler for the most remote operating fitting. sprinkler. Step 3. Tighten the sprinkler into Obstruction to Water Distribution the sprinkler fitting using only the Sprinklers are to be located in accor- W-Type 6 Sprinkler Wrench (Figure dance with the obstruction rules 3). With reference to Figure 1, apply of NFPA 13D, 13R, and 13 as appli- the W-Type 6 Sprinkler Wrench to the cable for residential sprinklers as wrench flats. well as with the obstruction criteria Series LFII Residential Recessed described within the Technical Data Pendent Sprinklers Sheet TFP490. The Series LFII Residential Recessed Operational Sensitivity Pendent Sprinklers must be installed Sprinklers are to be installed with a in accordance with the following deflector-to-ceiling distance of 1-1/4 to instructions. 4 inches. Step A. Install recessed pendent sprinklers in the pendent position with Sprinkler Spacing the deflector parallel to the ceiling. The minimum spacing between sprin- Step B. After installing the Style 20 klers is 8 feet (2,4 m). The maximum Mounting Plate over the sprinkler spacing between sprinklers cannot threads and with pipe thread sealant exceed the length of the coverage applied to the pipe threads, hand area(Table A or B) being hydraulically tighten the sprinkler into the sprinkler calculated(e.g., maximum 12 feet for a fitting. 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). TFP400 Page 4 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure(b,C) Max. Coverage Ordinary Temp.Rating Intermediate Temp.Rating Area(a) 155°F(68°C) 175°F(79°C) Minimum Deflector to Installation Spacing Ft.x Ft. Flow Pressure Flow Pressure Ceiling Type Ft. (m x m) GPM PSI GPM PSI (m) (L/min) (bar) (L/min) (bar) 12 x 12 13 7.0 13 7.0 Smooth (3,7 x 3,7) (49,2) (0,48) (49,2) (0,48) Ceilings 1-1/4 14 x 14 13 7.0 13 7.0 (4,3 x 4,3) (49,2) (0,48) (49,2) (0,48) 4 inches Recessed Beamed using Style 20 16 x 16 13 7.0 13 7.0 Ceilings per Escutcheon or 8 (4,9 x 4,9) (49,2) (0,48) (49,2) (0,48) NFPA 13D non-recessed (2,4) 18 x 18 17 12.0 17 12.0 or 13R pe13R or 13NFPAD (5,5 x 5,5) (64,3) (0,83) (64,3) (0,83) 1-1/4 to 1-3/4 inches below 20 x 20 20 16.7 20 16.7 bottom of (6,1 x 6,1) (75,7) (1,15) (75,7) (1,15) beam. (a) For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Requirement is based on minimum flow in GPM(LPM)from each sprinkler.The associated residual pressures are calculated using the nominal K-factor.Refer to Hydraulic Design under the Design Criteria section. (c) For NFPA 13 residential applications,the greater of 0.1 gpm/ft2 over the design area of the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS(TY2234) NFPA 13D, 13R,AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Maximum Minimum Flow and Residual Pressure(b,c) Coverage Ordinary Temp.Rating Intermediate Temp.Rating Area(a) 155°F(68°C) 175°F(79°C) Minimum Ft.x Ft. Deflector to Installation Spacing (m x m) Flow Pressure Flow Pressure Ceiling Type Ft. GPM PSI GPM PSI (m) (L/min) (bar) (L/min) (bar) 12 x 12 13 7.0 13 7.0 Smooth (3,7 x 3,7) (49,2) (0,48) (49,2) (0,48) Ceilings 14 x 14 14 8.2 14 8.2 4 inches (4,3 x 4,3) (53,0) (0,57) (53,0) (0,57) Recessed using Sle 16 x 16 15 9.4 15 9.4 Beamed Escutcheon20 or 8 (4,9 x 4,9) (56,8) (0,65) (56,8) (0,65) Ceilings per non recessed (2,4) NFPA 13D per NFPA 13D, 18 x 18 18 13.5 18 13.5 or 13R 13R,or 13 (5,5 x 5,5) (68,1) (0,93) (68,1) (0,93) 1-1/4 to 1-3/4 inches below 20 x 20 21 18.4 21 18.4 bottom of (6,1 x 6,1) (79,5) (1,27) (79,5) (1,27) beam. (a) For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Requirement is based on minimum flow in GPM(LPM)from each sprinkler.The associated residual pressures are calculated using the nominal K-factor.Refer to Hydraulic Design under the Design Criteria section. (c) For NFPA 13 residential applications,the greater of 0.1 gpm/ft2 over the design area of the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM SERIES LFII RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS(TY2234) NFPA 13D, 13R,AND 13 HYDRAULIC DESIGN CRITERIA TFP4OO Page 5 of 6 Care and Automatic sprinkler systems are recommended to be inspected, Maintenance tested, and maintained by a qualified Inspection Service in accordance with The TYCO RAPID RESPONSE Series local requirements and/or national LFII Residential Pendent and Recessed codes. Pendent Sprinklers(TY2234) must be maintained and serviced in accordance Limited with this section: Before closing a fire protection system Warranty main control valve for maintenance work on the fire protection system that For warranty terms and conditions, it controls, permission to shut down visit www.tyco-fire.com. the affected fire protection system must be obtained from the proper Ordering authorities and notify all personnel who may be affected by this action. Procedure Absence of the outer piece of an escutcheon, which is used to cover Contact your local distributor for a clearance hole, can delay sprinkler availability. When placing an order, operation in a fire situation. indicate the full product name and Part The owner must assure that the Number(P/N). sprinklers are not used for hanging Sprinkler Assembly any objects and that the sprinklers Specify: Series LFII (TY2234), K=4.9, are only cleaned by means of gently Residential Pendent Sprinkler, dusting with a feather duster; other- (specify)temperature rating, (specify) wise, non-operation in the event of finish, P/N (specify): a fire or inadvertent operation may 155°F(68°C) result. Natural Brass P/N 51-201-1-155 Sprinklers which are found to be Pure White(RAL 9010)* P/N 51-201-3-155 leaking or exhibiting visible signs of Signal White(RAL 9003) P/N 51-201-4-155 chrome Plated P/N 51-201-9-155 corrosion must be replaced. 175°F(79°C) Automatic sprinklers must never be Natural Brass P/N 51-201-1-175 painted, plated, coated, or other- Pure White(RAL 9010)* P/N 51-201-3-175 wise altered after leaving the factory. Signal White(RAL 9003) P/N 51-201-4-175 Modified sprinklers must be replaced. chrome Plated P/N 51-201-9-175 Sprinklers that have been exposed to *Eastern Hemisphere sales only corrosive products of combustion, but Recessed Escutcheon have not operated, should be replaced Specify: Style 20 Recessed if they cannot be completely cleaned Escutcheon with (specify*)finish, P/N by wiping the sprinkler with a cloth or (specify*) by brushing it with a soft bristle brush. Care must be exercised to avoid *Refer to Technical Data Sheet TFP770 damage to the sprinklers - before, Sprinkler Wrench during, and after installation. Specify: W-Type 6 Sprinkler Wrench, Sprinklers damaged by dropping, P/N 56-000-6-387 striking, wrench twist/slippage, or the Specify: W-Type 7 Sprinkler Wrench, like, must be replaced. Also, replace P/N 56-850-4-001 any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and mainte- nance of their fire protection system and devices in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authorities having jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. TFP400 Page 6 of 6 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products,LP. All rights reserved. t co TEFLON is trademark of The DuPont Corporation. Fire Protection Products ES-A-4000B Series 4000B AME S Reduced Pressure Zone Assemblies FIRE&WATERWORKS Sizes: 1/2" —2" (15—50mm) 9 �.- -- r I pf,P .. - 71%yy� te'_ ;y. i .0 2" (50mm)4000B-HC i . a 1/2"(15mm)4000B Features Series 4000B Reduced Pressure Zone Assemblies are designed to protect • Single access cover and potable water supplies in accordance with national plumbing codes and wa- modular check construction ter authority requirements. This series can be used in a variety of installa- for ease of maintenance tions, including the prevention of health hazard cross connections in piping • Top entry - all internals systems or for containment at the service line entrance. immediately accessible This series features two in-line, independent check valves, captured springs • Captured springs for safe and replaceable check seats with an intermediate relief valve. Its compact maintenance modular design facilitates easy maintenance and assembly access. Sizes 1/2"- 1" (15-25mm) shutoffs have tee handles. • Internal relief valve for reduced installation clearances • Replaceable seats for Specifications economical repair p • Bronze body construction for A Reduced Pressure Zone Assembly shall be installed at each potential health hazard location to prevent backflow due to backsiphonage and/or durability - '/2" to 2" (15-50mm) backpressure. The assembly shall consist of an internal pressure differential • Ball valve test cocks - relief valve located in a zone between two positive seating check modules screwdriver slotted -1/2" to 2" with captured springs and silicone seat discs. Seats and seat discs shall be (15-50mm) replaceable in both check modules and the relief valve. There shall be no • Large body passages provides threads or screws in the waterway exposed to line fluids. Service of all inter- low pressure drop nal components shall be through a single access cover secured with stain- • Compact, space saving design less steel bolts. The assembly shall also include two resilient seated isolation • No special tools required for valves, four resilient seated test cocks and an air gap drain fitting. The as- servicing sembly shall meet the requirements of: USC Manual 8th Editiont; ASSE Std. 1013; AWWA Std. C511; CSA B64.4. The assembly shall be an Ames Com- pany Series 4000B. Job Name Contractor Job Location Approval Engineer Contractor's P.O.No. Approval Representative Ames product specifications in U.S.customary units and metric are approximate and are provided for reference only.For precise measurements,please contact Ames Technical Service.Ames reserves the right to change or modify product design,construction,specifications,or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. www.amesfirewater.com Materials Pressure — Temperature Bronze body construction, silicone rubber disc material in the Suitable for supply pressures up to 175psi (12.06 bar) first and second check plus the relief valve. Replaceable poly- and water temperature to 180°F(75°C)continuous. mer check seats for first and second checks. Removable stain- less steel relief valve seat. Stainless steel cover bolts. Standardly furnished with NPT body connections. For optional Available Models bronze union inlet and outlet connections, specify prefix U Suffix: (1/2" -2")(15-50mm). Series 4000B furnished with quarter turn, B - quarter-turn ball valves full port, resilient seated, bronze ball valve shutoffs. LBV - less ball valves Standards LH - locking handle ball valves(open position) AWWA C511-92, USC Manual 8th Edition, IAPMO File No. 1563 SH - stainless steel ball valve handles HC -21/" inlet/outlet fire hydrant fitting (2" valve) Approvals S - bronze strainer Prefix: e), c-� ous - union connections c us 1013 B64.4 3/4"-2"(20-50mm) (LBV models only) Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. Approval models QT, U. IMPORTANT Inquire with governing authorities for local installation requirements. Weights — Dimensions _ �� - T A II!1IInt?LiJIff !!iI11i • < L > M < A Suffix HC - Fire Hydrant Fittings dimension "A" = 251/16 (637mm) MODEL SIZE(DN) DIMENSIONS STRAINER DIMENSIONS WEIGHT A B C D L M N in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kg. 4000B"" 1/2 15 10 250 45/8 117 3% 86 11/4 32 512 140 3 76 2 51 4.50 2.0 40008 M3** 3/4 20 10% 273 5 127 31/2 89 11/2 38 6% 171 35/6 84 25/6 59 5.75 2.6 40008 M2*" 1 25 16% 425 512 140 3 76 21/2 64 91/2 241 41 114 25/6 59 12.25 5.6 40006" 114 32 173/8 44 116 150 31/2 89 21/2 64 11% 289 51/8 130 31/8 79 14.62 6.6 40006" 11/2 40 171/2 454 6 150 312 89 21/2 64 111/8 283 _ 51/2 149 33/4 95 16.32 7.4 40006"" 2 50 213/8 543 7% 197 41/2 114 31/4 83 131/2 343 _ 63/6 157 41/2 124 30.00 13.6 Strainer sold separately **Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. 2 Capacity Performance as established by an independent testing laboratory. *Typical maximum system flow rate(7.5 feet/sec.,2.3 meters/sec.) kPa psi 1/4" (8mm) kPa psi 1" (25mm) O 138 20 0 207 30 J 117 17 -I 172 25 N a) 96 14 , 138 20 3 76 11 y y 103 15 d a 35 8 a 69 10 - - - OP 0 .25 .50 .75 1 1.17 gpm 34 5 0 .95 1.9 2.9 3.8 4.5 Ipm 0 0 0 5 10 20 30 40 50 60 70 80 gpm Flow Rate oP 0 19 38 76 114 152 190 228 266 304 Ipm 7.5 15 fps 2.3 4.6 mps Flow Rate kPa psi %" (1Omm) kPa psi 11/4" (32mm) w 138 20 y 172 25 p117 17 J 138 20 y 96 14 3 103 15 H 76 11 y 69 10 i 55 8 i a 35 5 _ a 34 5 - AP 0 .25 .50 .75 1 1.25 1.50 2.5 3.1 gpm 0 0 0 .95 1.9 2.9 3.8 4.8 5.7 9.5 11.8 Ipm AP 0 10 20 30 40 50 60 70 80 gpm Flow Rate 0 38 76 114 152 190 228 266 304 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate kPa psi 1/2" (15mm) 11/2" (4Omm) * 172 25 kPa psi * U3 0 207 30 J138 20 o 172 25 = 103 15 L 138 20 h 69 10 _ y 103 15 - ,o 2 69 10 cr. 35 5 a 34 5 Ap 0 1 2.5 5 7.5 10 12.5 15 gpm 0 0 0 3.8 9.5 19 28.5 38 47.5 57 Ipm pp 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 5 7.5 15 fps 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 1.5 2.3 4.6 mps 5 7.5 10 15 fps Flow Rate 1.5 2.3 3.0 4.6 mps Flow Rate 3/4" (2Omm) 2" (5Omm) kPa psi * kPa psi * 207 30 207 30 y 165 24 2 172 25 o 124 18 J 138 20 t 83 12 I - ---------o 2 103 15 -� fA / U) 41 6 - y 69 10 ` 34 5 13- 0 0 - 2 a 0 0 0 2 6 10 14 18 22 26 30 34 38 42 46 gpm APO 20 40 60 80 100 120 140 160 180 200 gpm OP 0 7.6 23 38 53 68 84 99 114 129 144 160175 Ipm 0 76 152 228 304 380 456 532 608 684 760 Ipm 7.5 15 fps 5 7.5 10 15 fps 2.3 4.6 mps 1.5 2.3 3.0 4.6 mps Flow Rate Flow Rate 3 For additional information, visit our web site at: www.amesfirewater.com A A M E S ISO 9001 FIRE&WATERWORKS A Division of Watts Regulator Company www.amesfirewater.com CERTIFIED 1427 North Market Blvd. • Suite #9 • Sacramento, CA 95834 • Phone: 916-928-0123 • Fax: 916-928-9333 ES-A-4000B 0625 ©Ames Fire&Waterworks, 2007 tqco I Fire & Building Products rapid response HOME FIRE SPRINKLER SYSTEM Technical Services: Tel: (800)381-9312/Fax: (800)791-5500 Figure 513D (13D) and 513D/R (13D/R) Riser Manifolds 1, 1-1/2, and 2 Inch (DN25, DN40, and DN50) For NFPA 13D/13R Residential Sprinkler Systems General Technical Description Data The Riser Manifolds described in this Approvals ■:■ f technical data sheet provide the nec- The Figure 513D (13D) and 513D/R essary waterflow alarm, pressure (13D/R) Riser Manifolds with a cover gauge,and drain equipment in a single tamper switch for the waterflow alarm assembly for use in NFPA 13D or 13R switch are UL Listed, ULC Listed, and residential sprinkler systems as fol- FM Approved. . lows: The Figure 513D (13D) and 513D/R NFPA 13D (13D/R) Riser Manifolds without a Figure 513D (13D) cover tamper switch for the waterflow 1 Inch11 e 513D alarm switch are UL Listed and FM(DN2r Female Thread x Female Thread Approved. . _ --- NFPA 13D/13R Maximum Working Pressure 175 psi (12,1 bar) line prior to performing the alarm test. ❑ Figure 513D/R (13D/R) Assembly The second option is to install an In- 1-1/2 Inch (DN40) The manifold body of the Figure 513 is spector's Test Connection down- Male Thread x Female Thread ductile iron, whereas the manifold stream of the Waterflow Alarm Switch. Male Thread x Male Thread body of the Figure 13 is cast iron. The (3) Never remove any piping compo- Figure 513D/R (13D/R) two assemblies are completely inter- nent nor correct or modify any piping 2 Inch (DN50) changeable in function, application, deficiencies without first depressuriz- Groove x Groove and end-to-end laying length. ing and draining the system. Male Thread x Groove Finish Step 1. Install the manifold body with The variety of sizes and end connec- Red painted. the flow arrow pointing in the down- tions allow cost effective and easy stream position using threaded con- transition to check valves, control Installation nections and/or listed mechanical valves, and system piping. The Riser grooved connections, as applicable. Manifolds may be installed in either the The Riser Manifolds may be installed Step 2. Connect the drain line, and horizontal (flow switch on top)or verti- in either the horizontal (flow switch on then close the drain valve. cal (flow going up). top) or vertical (flow going up). The inlet of the Riser Manifold may be di- Step 3. Refer to Figure 4 for wiring WARNING rectly connected to a shut-off control guidance. All wiring must be per- The Riser Manifolds described herein valve. formed in accordance with the Author- must be installed and maintained in ity Having Jurisdiction and/or the Na- compliance with this document, as NOTES tional Electrical Code. well as with the applicable standards (1) Where applicable pipe thread Step4. Place the system in service by of the National Fire Protection Asso- pp y sealant is to be applied sparingly. Use filling the system with water. When fill- ciation, in addition to the standardsany other authorities having r/sdic-of of non-hardening pipe thread sealant ing the system, partially open the con- tion. Failure to do so may impair the is recommended. trol valve to slowly fill the system. Fill- performance of these devices. (2) Provisions for an alarm test flow ing the system slowly will help avoid must be made. The alarm test flow is damaging the waterflow alarm switch. The owner is responsible for maintain to be through an orifice having a flow After the system is fully pressurized, ing their fire protection system and de- capacity equal to or smaller than the completely open the control valve. vices in proper operating condition. smallest orifice sprinkler in the system. The installing contractor or sprinkler One of two options can be considered. Step 5. Secure all supply valves manufacturer should be contacted The first option is to temporarily install open. with any questions. a test orifice in the outlet of the drain Page 1 of 6 APRIL, 2006 TFP960 Page 2 of 6 TFP960 NO. DESCRIPTION QTY. P/N 1 1"Manifold Body, 3-1/2"Female x Female NPT... 1 N/A (88,9mm)2 WaterflowAlarm Switch: VSR-SF modified with - L ,1/2" Female x Femal Paddle,UL/FM 1 971-096-01 VSR-SF modified with Paddle and Cover Tamper Switch,ULC/FM 1 976-519-01 3 200Pressure rkPa Water ' Waterr Pree sss ure Gauge .. 1 2343 3 =1 2 NOTES: / 1. Approximate weight,7.5 lbs.(3,4 kg). Waterflow 1.1 2. ULC Listed Manifolds are equipped with4111 _ Cover Tamper Switches installed internal 9-3/4" to the Waterfow Alarm Switches. (247,7 mm) MP 3. CH:Common Hardware laPPIMIIII 3-5/8" 2-7/8" (92,1 mm) . 1 (73,0 mm) lII;ILLi! f 3/4"NPT Drain Valve 4-1/2" (Normally Closed) (114,3 mm) 10" (254,0 mm) FIGURE 1 1 INCH(DN25)RISER MANIFOLD ASSEMBLY AND DIMENSIONS NO. DESCRIPTION QTY. P/N f , in, 1 1-1/2"Manifold Body, 3-1/2"Male x Female NPT 1 N/A (88,9 mm) 7 lMale x Male NPT 1 N/A ,�MPS u I _ 2 WaterflowAlarm Switch: ` d VSR-SF modified with Paddle,UUFM 1 971-096-00 VSR-SF modified with Paddle and Cover Tamper Switch,ULC/FM 1 976-519-02 3 300 psi/2000 kPa Water Pressure Gauge .. 1 2341 3 / 2 NOTES: Waterfow 1.1 1 1. Approximate weight,8.7 lbs.(3,9 kg). . 4111 = 2. ULC Listed Manifolds are equipped with Cover Tamper Switches installed internal 11-3/8" iHiIiiiiii to the Waterfow Alarm Switches. (288,9 mm) 3. CH:Common Hardware . 4-1/2" it I 5-3/8" (114,3 mm) (136,5 mm) _ huLl!. 1" NPT Drain Valve IFS 2-1/8" (Normally Closed) (54,0 mm) 10"(254,0 mm) Male x Female NPT Manifold 11-1/8"(282,6 mm) Male x Male NPT Manifold FIGURE 2 1-1/2 INCH(DN40)RISER MANIFOLD ASSEMBLY AND DIMENSIONS TFP960 Page 3 of 6 NO. DESCRIPTION QTY. P/N _: ,_r 1 2"Manifold Body, 3-1/2" Groove x Groove 1 N/A (88,9 mm) Male NPT x Groove 1 N/A 2 Waterflow Alarm Switch: —� .CD -- VSC with Paddle, UL/FM 1 976-357-01 VSC with Paddle and Cover Tamper Switch, ULC/FM 1 976-520-01 3 kPa — 3 / 2 Water Press ure Gauge .. 1 2341 I=1 Optionally Grooved or NOTES: 1 Waterflow Male NPT 1. Approximate weight,11.0 lbs.(5,0 kg). \ Supply End I Connection 2. ULC Listed Manifolds are equipped with Cover Tamper Switches installed internal 12" to the Waterflow Alarm Switches. (304,8 mm) II 3. CH:Common Hardware } 4-1/2" 5-7/16" W (114,3 mm) (138,1 mm) III 11011 U 1" NPT FIGURE 3, Drain Valve 2-1/4" (Normally Closed) (57,2 mm) 2 INCH(DN50)RISER MANIFOLD ASSEMBLY AND DIMENSIONS 13"(330,2 mm) Groove x Groove, Male NPT x Groove result in operation of the associated recorded for the system when it was Care and alarms. Consequently, notification first installed. must be given to the owner and the fire Maintenance department, central station, or other Alarm Test Procedure With A Test signal station to which the alarms are Orifice (See Installation Note 2) The following inspection procedure connected, and notification must be must be performed as indicated, in ad- given to the building occupants. Step 1. Temporarily install a test ori- dition to any specific requirements of fice in the drain line outlet. the NFPA, and any impairment must Before closing a fire protection system be immediately corrected. control valve for inspection or mainte- Step 2. Fully open the drain valve. nance work on the fire protection sys- Make certain that drainage water will The owner is responsible for the in- tern that it controls,permission to shut not cause any damage or injury. spection, testing, and maintenance of down the effected fire protection sys- Step 3.Verify operation of the associ- their fire protection system and de- tern must first be obtained from the vices in compliance with this docu- proper authorities and all personnel ated alarms. ment, as well as with the applicable who may be affected by this action Step 3. Close the drain valve. standards of the National Fire Protec- must be notified. tion Association (e.g., NFPA 25), in Step 4. Remove the test orifice from addition to the standards of any After placing a fire protection system the drain line outlet. authority having jurisdiction. The in- in service, notify the proper authorities stalling contractor or product manufac and advise those responsible for moni- Alarm Test Procedure With An turer should be contacted relative to toring proprietary and/or central sta- Inspector's Test Connection (See any questions. tion alarms. Installation Note 2) It is recommended that automatic Flow Test Procedure Step 1.Fully open the Inspector's Test sprinkler systems be inspected, Connection Valve. Make certain that tested, and maintained by a qualified Step 1. Fully open the drain valve. drainage water will not cause any dam- Inspection Service in accordance with Make certain that drainage water will age or injury. local requirements and/or national not cause any damage or injury. codes. Step 2.Verify operation of the associ Step 2. Verify that the residual (flow- ated alarms. NOTES ing) pressure indicated by the pres- Step 3. Close the Inspector's Test No attempt is to be made to repair any sure gauge is no less that originally Connection Valve. Riser Manifold component in the field. recorded for the system when it was Only the pressure gauge or waterflow first installed. alarm switch can be replaced. If any Step 3. Close the drain valve. other problems are encountered the entire riser manifold must be replaced. Step 4.Verify that the static(not flow ing) pressure indicated by the pres- The flow and alarm test procedure will sure gauge is no less that originally Page 4 of 6 TFP960 SWITCH TERMINAL CONNECTIONS UNINSULATED CLAMPING SEVERED LOOPED SECTION CAUTION: PLATE STRIPPED SINGLE An uninsulated section of a TERMINAL ENDS CONDUCTOR single conductor is not � SEPARATE permitted to be looped around CONDUCTORS CLAMPING , the terminal and serve as two % °1fr PLATE separate connections.The TERMINAL wire must be severed to serve ', INCOMING Nkomo as two separate connections, 41r-o- thereby providing supervision of the connection in the event that the wire becomes dislodged from the terminal. OUTGOING IMPROPER CONNECTION METHOD PROPER CONNECTION METHOD WATERFLOW SWITCH TYPICAL ELECTRICA CONNECTIONS CONTACTS SPDT(Form C) END OF LINE 40 LOCAL RESISTOR CONTACT RATING .... 5A @ 125 VAC SIGNAL 2.5A @ 30 VDC DEVICE NC NO NC yo_er NO• �G NC M 1 I COM COM CONTROL POWER PANEL NO FLOW NON-SUPERVISED STYLE B/CLASS B CONDITION CIRCUIT SUPERVISED CIRCUIT (SEE NOTE) NOTE: For supervised circuits,see"Switch Terminal Connections"above.The Waterflow Alarm Switch has two switches,one can be used to operate a central station,proprietary or remove signaling unit,while the other contact is used to operate a local audible or visual annunciator. COVER TAMPER SWITCH(ULC ASSEMBLIES ONLY) CONTACTS SPDT(Form C) CONTACT RATING .... 3A @ 250 VAC 5A @ 125 VAC 1mA@5VDCmin. NO I\ • NC COM CONTACTS SHOWN WITH COVER IN PLACE FIGURE 4 WIRING GUIDANCE TFP960 Page 5 of 6 Limited Ordering Warranty Information Products manufactured by Tyco Fire& Riser Manifold: Building Products (TFBP) are war- Specify;Size(specify),Figure(specify ranted solely to the original Buyer for 513D or 513D/R, (specify connection ten (10)years against defects in mate- type inlet x outlet) Riser Manifold rial and workmanship when paid for (specify-without or with)a cover tarn- and properly installed and maintained per switch for the waterflow alarm under normal use and service. This switch, P/N (specify). warranty will expire ten (10) years from date of shipment by TFBP. No NOTES warranty is given for products or corn- Orders for Figure 513D or513D/R may ponents manufactured by companies be filled with a Figure 13D or 13D/R, not affiliated by ownership with TFBP respectively. The two assemblies are or for products and components which completely interchangeable in func- have been subject to misuse,improper tion, application, and end-to-end lay- installation, corrosion, or which have ing length. not been installed, maintained, modi- If a ULC Listing is required, the Riser fied or repaired in accordance with ap- Manifold must be ordered with a cover plicable Standards of the National Fire tamper switch for the waterflow alarm Protection Association, and/or the switch. standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either UL/ULC/FM Assemblies repaired or replaced, at TFBP's sole With Cover Tamper Switch option. TFBP neither assumes, nor 1 Inch(DN25) authorizes any person to assume for it, FT x FT P/N 4085 any other obligation in connection with 1-1/2 Inch(DN40) MT x FT P/N 4088 the sale of products or parts of prod- 1-1/2 Inch(DN40) ucts.TFBP shall not be responsible for MT x MT P/N 4089 sprinkler system design errors or inac- 2 Inch(DN50) curate or incomplete information sup- G x G P/N 4093 plied byBuyerBuyer's re re- 2 Inch(DN5o) or y repre- x G P/N 4094 sentatives. In no event shall TFBP be liable, in UL/FM Assemblies contract, tort, strict liability or under Without Cover Tamper Switch other legal theory, for incidental, 1 Inch(DN25) any g y FT x FT P/N 4047 indirect,special or consequential dam- 1-1/2 Inch(DN40) ages, including but not limited to labor MT x FT P/N 4057 charges, regardless of whether TFBP 1-1/2 Inch(DN40) was informed about the possibility of MT x MT P/N 4058 such damages, and in no event shall 2 Inch(GN50) g G x G P/N 4059 TFBP's liability exceed an amount 2 Inch(DN50) equal to the sales price. MT x G P/N 4064 The foregoing warranty is made in lieu of any and all other warranties. ex- Replacement Parts: press or implied, including warranties Specify: (description)for use with Fig- of merchantability and fitness for a par- ure 513D, 513D/R, 13D, or 13D/R ticular purpose. Riser Manifold, P/N (Ref. Figure 1, 2 This limited warranty sets forth the ex or 2, as applicable). clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law.The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Page 6 of 6 TFP960 TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue,Lansdale, Pennsylvania 19446 tLfCfl I Flow Tyco Fire Control Products BlazeMaster ° FIRE SPRINKLER PIPE & FITTINGS SUBMITTAL SHEET TYCO FIRE PRODUCTS 451 North Cannon Avenue Lansdale, Pennsylvania 19446 www.tyco-fire.corn TECHNICAL SERVICES TEL: (800) 381-9312 • Fax: (800) 791-5500 E-MAIL: techserv@tycofp.com -1 ( i;t No. 19-1.5 TD915 Ad. 4-1.1.20 9/2001 sO) Introduction Tyco Fire Products (TFP) BlazeMaster°CPVC pipe and the same time, they provide superior heat resistance and fittings are designed exclusively for use in wet pipe strength as compared to traditional CPVC and PVC piping automatic fire sprinkler systems.They are made from a materials used in the plumbing trade. Various adapters are specially developed thermoplastic compound composed of available to connect CPVC pipe to metallic piping.All female post chlorinated polyvinyl chloride (CPVC) resin and state of pipe thread adapters have brass inserts for durability. the art additives. TFP BlazeMaster®CPVC products are Grooved adapters connect directly to grooved end valves easier to install than traditional steel pipe systems, and at and metallic pipe, with flexible grooved end couplings. Technical Data Sizes: 3/4"-3" Manufacture Source: U.S.A. Maximum Working Pressure: 175 psi Material: Approvals: UL, FM, CUL, NSF, Dade County, LPCB, Pipe: ASTM F442, SDR 13.5 MEA, and the City of Los Angeles Fittings: ASTM F438 (Sch. 40) and Note: See current TFP BlazeMaster Installation Instructions and ASTM F439 (Sch. 80) Technical Manual,for exact listing/approval information Color: Orange Pipe Nom.Pipe Size Avg.O.D. Inches Avg. I.D. Inches Wt.Lbs./Ft. Wt.H2O filled Pipe Lbs./Ft. Ft. of Pipe per Lift Wt.per Lift Lbs. 3/4" 1.050 0.874 0.17 0.43 7875 1413 1" 1.315 1.101 0.26 0.67 5040 1320 11/4" 1.660 1.394 0.42 1.07 2835 1191 11/2" 1.900 1.598 0.55 1.40 2205 1136 2" 2.375 2.003 0.86 2.20 1260 1063 21/2" 2.875 2.423 1.26 3.22 1215 1531 3" 3.500 2.952 1.87 4.79 720 1344 Fittings T/O IN T/O 7ip T/O � 45° Elbow _ �* Reducing _ 90° Elbow = �� 90° Elbow -® T/OZ vo -111li -III Part No. Size Sch. T/O Wt. Part T/O Wt. Part No. Size Sch. T/O Wt. Size Sch. 80050 3/4" 40 3/8" 0.08 lb. No. 1 2 lb. 80025 3/4" 40 9/16" 0.09 lb. 80051 1" 40 3/8" 0.11 lb. 80032 1" x3/4" 40 11/16" 13/,6" 0.16 80026 1" 40 3/4" 0.14 lb. 80052 11/4" 40 3/4" 0.20 lb. 80027 11/4" 40 '/e" 0.21 lb. 80053 1'/2" 80 7/16" 0.31 lb. 80028 11/2" 80 11/16" 0.40 lb. _80054 2" 80 3/4" 0.56 lb. 80029 2" 80 11/4" 0.79 lb. 80055 21/2" 80 3/4" 0.89 lb. 80030 21/2" 80 11/2" 1.14 lb. 80056 3" 80 1" 1.19 lb. 80031 3" 80 113/16" 1.82 lb. 1 I T/O -T/O I L ,____ Tee _._._._.__. T'O Reducing �p�_ Cross _._/._. I . _ Cross n I T/O T/O T/O � -T/O _ � T/O' MU. T/O' T/O I l T/O Part No. Size Sch. T/O Wt. Part T/O Wt. Part No. Size Sch. T/O Wt. 80000 3/4" 40 5/8" 0.11 lb. No. Size Sch. 1 2 lb. 80009 3/4" 40 9/16" 0.13 lb. 80001 1" 40 3/4" 0.19 lb. 80015 1"x3/4" 40 11/16" 11/16" 0.28 80010 1" 40 15/16" 0.23 lb. 80002 11/4" 40 7/8" 0.26 lb. 80011 11/4" 40 15/16" 0.34 lb. 80003 11/2" 80 1" 0.51 lb. 80012 11/2" 80 11/16" 0.67 lb. 80004 2" 80 13/8" 0.90 lb. 80013 2" 80 13/8" 1.00 lb. 80005 21/2" 80 19/16" 1.59 lb. 80014 21/2" 80 19/16" 1.91 lb. 80006 3" 80 111/16" 2.41 lb. 80008 3" 80 113/16" 2.89 lb. CFRTIFIF "CONIPPNY -1-TIO T/O -1 -T/O 7 Coupling _._._._._._._._._. Cap _A.r_ Reducer _._.__._._._._._. Bushing = ` Part No._ Size Sch._T/O Wt. Part No. Size Sch. T/O Wt. Part No. Size Sch. T/O Wt. - 80200 1" x 3/4" 40 7/16" 0.04 lb. 80075 3/4" 40 1/8" 0.07 lb. 80100 3/4" 40 5/16" 0.04 lb. 80201 11/4"x3/4" 40 7/16" 0.11 lb. 80076 1" 40 1/8" 0.11 lb. 80101 1" 40 3/8" 0.06 lb. 80202 11/4"x 1" 40 5/16" 0.12 lb. 80077 11/4" 40 3/16" 0.12 lb. 80102 11/4" 40 1/2" 0.10 lb. 80203 11/2" x3/4" 80 5/8" 0.16 lb. 80078 11/2" 80 3/16" 0.25 lb. 80103 11/2" 80 5/8" 0.20 lb. 80204 112"x 1" 80 1/2" 0.14 lb. 80079 2" 80 3/16" 0.38 lb. 80104 2" 80 5/8" 0.31 lb. 80205 11/2" x 11/4" 80 3/8" 0.17 lb. 80080 21/2" 80 3/16" 0.67 lb. 80105 21/2" 80 7/8" 0.58 lb. 80206 2" x 3/4" 80 3/4" 0.27 lb. 80081 3" 80 3/16" 0.91 lb. 80106 3" 80 1" 0.88 lb. 80207 2" x 1" 80 11/16" 0.26 lb. 80208 2" x 11/4" 80 9/16" 0.24 lb. T/O 80209 2" x 11/2" 80 7/16" 0.19 lb. Grooved MI 80215 2'/2"x 1" 80 115/16" 0.42 Ib. Coupling 0.D. 80214 21/2" x 11/4" 80 13/4" 0.45 Ib. Adapter 80213 21/20 x 11/2" 80 15/8" 0.46 lb. 80211 21/2"x 2" 80 19/16" 0.29 lb. Part No. Size Sch. T/O Wt. Pipe OD 80210 3" x 2" 80 2 3/16" 0.72 lb. 80160 11/4" x 11/4" Grooved 40 2 5/16" 0.78 lb. 11/4" (1.660") 80212 3" x 21/2" 80 115/16" 0.47 lb. 80161 11/2" x 11/2" Grooved 80 2 5/16" 0.95 lb. 11/2" (1.900") 80162 2" x 2" Grooved 80 2 5/16" 1.42 lb. 2" (2.375") 80163 21/2" x 21/2" Grooved 80 2 5/16" 2.28 lb. 2'/2" (2.875") ' J. 80164 3" x 3" Grooved 80 21/4" 3.00 lb. 3" (3.500") Reducing ` '-. -.-.- 80168 3" x 76.1mm Grooved 80 21/4" 2.72 lb. 76.1mm (3.000") Tee _L T/0' T/0' in T/O Part T/O Wt. No.80132 Size Sch. 1 2 3 lb. Female 3/4"x x 1 3/4" " 40 3/4" 3/4" 5/8" 0.14 liTtill Adapter .� 80133 1"x3/4"x3/4" - - 40 /2"_ "/,6" 3/4" 0.14 80134 1" x 3/4"x 1" 40 5/8" 3/4" 3/4" 0.17 Part No. Size Sch. T/O Wt. 80260 1" x 1" x 3/4" 40 3/40 3/40 11/16" 0.16 80142 3/4"x 3/4" NPT 40 5/8" 0.41 lb. 80135 11/4" x 1"x3/4" 40 7/16" 3/4" 15/16" 0.21 80145 1"x 1" NPT 40 3/4" 0.63 lb. 80136 _ 1'/4"x 1"x 1" 40 11/16" 3/4" 15/16" 0.22 80146 11/4"x 11/4" NPT 40 7/8" 1.03 lb. 80137 _ 11/4"x 1"x 11/4" _ 40 13/,6" 5/160_ 3/16" 0.26 80147 11/2"x 11/2" NPT 80 1" 1.42 lb. 80261 11/4"x 11/4"x 3/4" 40 5/8" 5/8" 7/8" 0.23 80148 2"x 2" NPT 80 13/8" 2.66 lb. 80262 11/4" x 11/4" x 1" 403/4" 3/4" /8" 0.26 80138 1'/4" X 11/4" X 11/2" 80 1" 1" 1" 0.43 T/0 80140 11/2" x 11/4" x 3/4" 80 '/2" 5/8" 1" 0.36 '4.••_ 80141 11/2" x 11/4" x 1" 80 1/2" 5/8" 11/8" 0.38 Male 80263 11/2"x 11/2"x3/4" 809/,6" 9/16"_ 1- " 0.36 Adapter . ...,, 80264 11/2" x 11/2"x 1" 809/,6" 9/16" 1- " 0.38 80275 11/2"x 11/2"x 11/4" 80 7/8" 7/8" 1" 0.45 Part No. Size Sch. T/O Wt. 80265 2" x 2" x 3/4" 80 3/4" 3/4" 13/8" 0.61 80157 3/4" x 3/4" NPT 40 15/16" 0.33 lb. 80266 2" x 2"x 1" 80 7/8" 7/8" 13/8" 0.66 80158 1" x 1" NPT 40 13/8" 0.56 lb. 80274 2"x 2" x 11/4" 80 1" 1" 13/8" 0.74 80267 2"x 2"x 11/2" 80 11/8" 11/8" 13/8" 0.78 T/O 80271 21/2" x 21/2"x 1" 80 111/16" 1 11/16"" 19/16" 1.43 80272 21/2"x 21/2"x 11/4" 80 111/16" 111/16" 19/16" 1.46 Reducing J 80273 21/2" x 21/2"x 11/2" 80 111/16" 111/16" 19/16" 1.48 Coupling 80276 21/2"x 21/2"x 2" 80 111/16" 111/16" 19/16" 1.50 80270 3"x 3" x 11/2" 80 13/4" 13/4" 113/16" 2.28 Part No. Size Sch. T/O Wt. 80268 3"x 3"x 2" 80 13/4" 13/4" 13/4" 2.25 80220 1" x3/4" 40 1/8" 0.08 lb. 80269 3"x 3"x 21/2" 80 13/4" 13/4" 115/16" 2.44 4 iso 8""2 CERTIFIED COMPANY T/O T/O Sprinkler Head Adapter _ �' Sprinkler HeadAdapter _ri with Brass Threaded Insert IT with Brass Threaded Insert Part No. Size Sch. T/O Wt. Part No. Size Sch. T/O Wt. 80175E 3/4" x 1/2" NPT 80 7/16" 0.20 Ib. 80175W 3/4" x1/2" NPT 40 7/16" 0.19 Ib. 80176E 1" x 1/2" NPT 80 716" 0.22 Ib. 80176W 1" x1/2" NPT 40 7/16" 0.18 Ib. 80177WL 3/4" x1/2" NPT 40 9/16" 0.16 Ib. 80179 1 x3/4" NPT 40 3/4" 0.43 Ib. —T/O' J jL._ T/O ^4 j Back-to-Back Cross -.--.--.-. .-i_. .-.--.--.- Sprinkler Head Adapter -11574011111 with Brass Threaded Insert (Spigot) ----- —T/O' with Brass Threaded Insert T/O I T/O: Part No. Size Sch. T/O Wt. Part T/O Wt. 80177L 3/4" x1/2" NPT 40 1/2" 0.16 Ib. No. Size Sch. 1 2 Ib. 80178 1" x'/2" NPT 40 1/2" 0.20 Ib. 80462 1"x 1"x'/2" NPT x'/2" NPT 40 5/8" 1'/3" 0.46 80463 1"x 1"x'/2" NPT x'/2" NPT 40 5/8" 15/16" 0.47 T/O' Sprinkler Head Adapter o 90 Elbow T/o= Back-to-Back Tee T/ with Brass Threaded Insert with Brass Threaded Insert . �i`��� T/O 2 T/O Part T/O Wt. Part Size Sch. T/O Wt. No. Size Sch. 1 2 Ib. No. 1 2 lb. 80199 3/4" x 1/2" NPT 40 5/8" 15/16" 0.20 80459 1" x 1/2" NPT x1/2" NPT 40 11h6" 15/16" 0.48 80189 1" x 1/2" NPT 40 13/16" 13/16" 0.26 80460 1" x1/2" NPT x1/2" NPT 40 11h6" 11/8" 0.46 Part T/O Wt. No. Size Sch. 1 2 3 lb. 80250 3/4"x 3/4"x 1/2" NPT 40 5/8" 5/8" 1" 0.22 80251 1"x 1"x'/2" NPT 40 11/168 11/16" 13/16" 0.29 80249 1"x 1" x 1" NPT 40 15/16" 15/16" 1'/16" 0.73 Sprinkler Head Adapter J T/O" 80256 11/4" x 1"x 1/2" NPT 40 3/46" 9/16" 11/8" 0.30 Tee ------- ------� 80252 11/4"x 11/4"x 1/2" NPT 40 3/46" 7/16" 11/8" 0.31 with Brass Threaded Insert • —' • 80257 11/2"x 11/4"x 1/2" NPT 80 9/16" 5/8" l'/16" 0.43 T/0'-1—I T/02 80254 11/2"x 11/2"x 1/2" NPT 80 9/16" 9/16" 1'/16" 0.46 80258 2"x 11/2"x 1/2" NPT 80 1/2" 5/8" 15/8" 0.56 80253 2"x 2"x 1/2" NPT 80 1/2" 1/2" 15/8" 0.62 Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten(10)years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten(10)years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse,improper installation,corrosion,or which have not been installed,maintained,modified or repaired in accordance with applicable Standards of the National Fire Protection Association(NFPA),and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced,at Tyco Fire Products sole option. Tyco Fire Products neither assumes,nor authorizes any person to assume for it,any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE,IN CONTRACT,TORT,STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY,FOR INCIDENTAL,INDIRECT,SPECIAL OR CONSEQUENTIAL DAMAGES,INCLUDING BUT NOT LIMITED TO LABOR CHARGES,REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCT'S LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED,INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. �[ICO/Flow Control IP Tyco Fire roducts .y hi ] - �_ j.,� _�� for WET FireFR / iYR• I 4 I • 1 • • . Time Tested. . . 15 years and millions of gallons installed if ' i •,. '. V . -- . I ,• FireFighte"TM iv 1ne ahler ' i Freeze Protection Fluid Fred*praiccilan fJln�a '5 r 1loy,pro F�•{I• ....NtFM•TOVIC. 5o F U Glycerine solutions for CPVC wet fire sprinkler systems FireFighterTM nr i Freeze Protection Fluid Propylene Glycol solutions for Fire Fighter-PGmost wet fire sprinkler systems Fr4eic Pr t tdon F+wld `-1 F IIu� pr Fscl■pn,rloIM•TiaXIe, z, r4 il.• Easy to Use �iEsykL SiFiEM�r>FI •OO NST plLlfrE �111�14 wer rir.�+o�a•t7�o. • • in- -- J -•.- Available in 5 gallon containers, 55 gallon drums, totes or tank trucks. ~ "'= • Ready to use or concentrates ^_ � :—=-- I • Custom blends available -6• -•.7Aall J � ,�, Easy to Maintain ,_' = Instruments necessary 1IJ to test the fluids and maintain the protection Hydrometer The Noble Company RefractometerNa it--:----------------- 800-878- 5788 4 -- r www.noblecompany.com •• FireFighter is a trademark of The Noble Company. Digital Refractometer PRODUCT DESCRIPTION FDA References FireFighter GL and FireFighter PG are non-toxic*' anti- GRAS:FireFighter GL and FireFighter PG are consid- freezes designed specifically for fire protection systems. ered"Generally Regarded as Safe"(GRAS)by the Fed- These products are used in place of water and other wa- eral Food and Drug Administration. ter-like fluids in sprinkler systems where freezing may either cause damage or interfere with the functioning of systems or equipment,and/or toxicity to humans or ani- Typical Physical Properties of "Ready-to-Use" mals is a concern. FireFighter GL and FireFighter PG "Ready-to-Use" FireFighter GL FireFighter PG FireFighter GL Color: Orange Red FireFighter GL is a Glycerine based material which is compatible with all approved types of pipe,including Density @ 77°F: 1.137 1.026 BlazeMaster®CPVC sprinkler pipe and fittings. (grams/ml) Active Ingredient:USP or CP Glycerine Viscosity @ 77°F: 7.05 6.15 Other ingredients:Water (Centipoise) Viscosity Reduction Agent Dye pH: 7.0 8.0-9.6 Boiling Point @ Atmospheric Pressure: FireFighter PG (760 mm) 212°F 222°F FireFighter PG is a Propylene Glycol based material Minimum Flow which is compatible with all approved types of sprinkler Temperature: -15°F -15°F systems,with the exception of CPVC. Minimum Burst Active Ingredient:Propylene Glycol Temperature: -50°F -50°F Other Ingredients:Water (Hard Freeze) Viscosity Reduction Agent Inhibitor Flash Point 350°F 214°F Dye Fire Point 400°F 220°F Concentrate (Pensky-Martens Closed Cup) Flammability FireFighter GL and FireFighter PG are not flammable Other FireFighter Antifreeze Products since they have no measurable flash point;however,both products can flash or burn if the water content is evapo- • FireFighter GL Concentrate rated off.No harmful fumes are produced. • FireFighter PG Concentrate(New Formula) • GL and PG Custom Blends For specifications on these products please contact us. Toxicological,Environmental and Health Information *FireFighter is a Trademark of The Noble Company *BlazeMaster is a Registered Trademark of Noveon FireFighter GL and FireFighter PG are virtually harmless *'Non-Toxic is used to describe extremely low chronic and acute toxic- to animals or plants;however,the disposal of these mate- ity.No maximum safe intake for humans has been established.The product is considered GRAS by The Food and Drug Administration. rials should be in conformance with national,state and local health codes. Sizes FireFighter GL and FireFighter PG are available in: • 1 gallon plastic bottles (6 per case, PG Ready- RECOMMENDED CONCENTRATIONS to-Use only) • 5 gallon pails • 30 gallon drums • 55 gallon drums • 275 or 330 gallon totes FireFighter GL Ready-to-Use • 5000 gallon tank truck Specific Gravity Freeze Point Burst Point @ 77°F System Requirements and Limitations 1.141 -15°F -50°F All fire protection sprinkler systems that use Fire- 1.116 5°F -45°F Fighter GL and FireFighter PG should conform to 1.102 0°F -40°F local, state and NFPA requirements. The use of an- tifreeze within these systems should also conform 1.096 10°F -35°F to NFPA requirements. Use of antifreeze solutions should also be in confor- mance with any state or local health codes. Please FireFighter PG Ready-to-Use contact your local health authorities if you have any questions concerning the codes in your area. Specific Gravity Freeze Point Burst Point @ 77°F Maintenance 1.033 0°F -50°F Chemicals which compose FireFighter GL and Fire- 1.028 to°F -20°F Fighter PG can break down over time. NFPA 25 re- 1.024 +15°F 0°F quires that the freezing point of the system should be tested at least once a year. Periodic testing of 1.020 +20°F +10°F systems is critical to maintaining the proper con- centration and freeze point of the fluid. Leaks, pressure surges and temperature changes to the system can cause antifreeze to flow out of the sys- tem or water to flow into the system changing the FireFighter GL Concentrate freeze temperature. GL Concentrate Freeze Point Specific Gravity @60°F Testing To test the freeze protection level of FireFighter GL 40% +5°F 1.100 or FireFighter PG the correct instrument must be used. 50% -15°F 1.133 For testing FireFighter GL we have two instruments. 60% 22°F 1.151 A lab grade hydrometer or a digital refractometer. 70% -40°F 1.165 For testing FireFighter PG we have three instru- ments for test. A lab grade hydrometer, an analog refractometer or a digital refractometer. When testing indicates that the solution has weak- ened, empty the system and replace with fresh FireFighter GL or FireFighter PG, according to the installation instructions. For further information concerning correct testing procedures and test instruments, contact our tech- nical services department and ask for"How to Choose the Correct Antifreeze Loop Tester': RECOMMENDED CONCENTRATIONS FireFighter PG Concentrate (New Formula) The Noble Company FF PG Freeze Point Specific Gravity Concentrate @ 60°F P.O. Box 350 60r -60°F 1.045 Grand Haven, MI 49417-0350 50% -26°F 1.041 www.noblecompany.com 40% -6°F 1.034 Phone: (231) 799-8000 30% +9°F 1.027 (800) 878-5788 Fax: (231) 799-8850 Fast Fax: (800) 272-1519 ACCESSORIES • Lab Grade Hydrometer • Analog Refractometer • Digital Refractometer AFSA i�+r#i**n Firm. 94pr1Nkl.r A iomcIjt AVAILABILITY M E B E FireFighter GL and Firefighter PG are available throughout the U.S. throughaino-ku, w • wholesale distributors. Please contact The Noble Company for your local representa- tive and wholesaler. TECHNICAL SUPPORT I MEM6ER Specifications, installation design, instal- lation techniques and unique applications will be reviewed upon request. Address inquiries ATTN: FireFighter Technical Support, Email: www.noblecompany.com or phone us at: 800-878-5788 Field services are available through fac- tory representatives and Noble Company staff. Contact The Noble Company for local representatives. Additional product information and MSDS are available immediately through our website at www.noblecompany.com or our Fast Fax service at 1-800-272-1519. These are available 24 hours a day, 7 ©2004 Form#FFPIG 1004 days a week. Supercedes 0604 WILKINS Model WXTP a zuRN,,, company Water Thermal Expansion Tank SPECIFICATION SUBMITTAL SHEE-' - APPLICATION Air Designed for installation on potable water lines between the backflow preventer or pressure reducing valve and the water heater to protect against water thermal expansion. When ii, system pressure increases,water enters the tank's bladder which expands into the pre-charged air chamber, keeping system pressure below the relief valve setting. imr STANDARDS COMPLIANCE FEATURES • IAPMO®Listed NSF Sizes (liters): ❑ 8 ❑ 18 ❑ 32 ❑ 50V • NSF®Listed `® ❑ 75V ❑ 120V ❑ 165V ❑ 320V Certified to ANSI/NSF 67 (V=vertical,free-standing) Maximum working water pressure 150 PSI MATERIALS End connections Threaded NPT ANSI B1.20.1 Outer shell High Grade Steel Precharge(adjustable) 40 PSI Coatings Epoxy finish(outer shell) Connection Brass (sizes: 8 thru 32) 5 year warranty Stainless Steel (sizes: 50V thru 320V) Bladder Butyl Rubber(FDA approved) LIc ACCESSORIES �A U BR4 - water pressure reducing valve 1 ° ❑ TP1100A - temperature&pressure relief valve ❑ P1000A - pressure relief valve ❑ 975XL - reduced pressure backflow preventer IU B B NOTE: Model WXTP tanks are certified to NSF Standard 61 cold, but are suitable for temperatures up to 200°F. c - 0 HAJ WXTP 50V-320V WXTP 8-32 DIMENSIONS&WEIGHTS(do not include pkg.) TANK SPECIFICATIONS MAXIMUM TOTAL FACTORY DIMENSIONS MODEL WEIGHT WORKING VOLUME ACCEPTANCE PRECHARGE DIAMETER HEIGHT SYSTEM NUMBER PRESSURE GALLON VOLUME (PSI) CONNECTION S in. mm in. mm lbs. kg WXTP-8 150 PSIG 2.1 0.84 40 8 1/2 216 11 1/2 292 3/4" MNPT 7 3.2 WXTP-18 150 PSIG 4.5 1.8 40 10 254 15 381 3/4" MNPT 10 4.5 WXTP-32 150 PSIG 8.5 3.4 40 12 1/2 318 19 3/16 487 3/4" MNPT 15 6.8 WXTP-50V 150 PSIG 14 5.6 40 16 406 21 11/16 551 1" FNPT 32 14.5 WXTP-75V 150 PSIG 20 8.0 40 16 406 28 13/16 732 1" FNPT 39 17.7 WXTP-120V 150 PSIG 32 12.8 40 21 533 27 13/16 706 1" FNPT 60 27.2 WXTP-165V 150 PSIG 44 17.6 40 21 533 36 3/16 919 1 1/4" FNPT 72 32.7 WXTP-320V 150 PSIG 85 34.0 40 26 660 44 7/16 1129 1 1/4" FNPT 140 63.4 NOTE: RELIEF VALVE MUST BE SET AT 150 PSIG MAXIMUM DOCUMENT#: REVISION: WXT-WXTP 4/05 Page 1 of 2 SIZING CHART Supply WATER HEATER CAPACITY (U.S. gal) Pressure(psig) 20 30 40 50 60 80 100 120 150 175 200 40 8 8 8 8 8 18 18 18 32 32 32 _ 50 8 8 8 8 8 18 18 18 32 32 32 55 8 8 8 8 8 18 18 18 32 32 32 60 8 8 8 8 18 18 18 18 32 32 32 _ 70 8 8 8 8 18 18 18 18 32 32 32 80 8 8 8 8 18 18 18 32 32 32 32 90 8 8 8 18 18 18 32 32 32 50V 50V 100 8 8 18 18 18 32 32 32 50V 50V 50V 110 8 I 1818 18 1 32 32 32 1 50V 50V 75V 75V 120 18 18 I 32 32 32 50V 50V 50V 120V 120V 120V Supply WATER HEATER CAPACITY (U.S. gal) Pressure(psig) 240 260 280 300 350 400 450 500 600 800 1000 40 50V 50V 50V 50V 50V 75V 75V 75V 120V 120V 165V 50 50V 50V 50V 50V 50V 75V 75V 75V 120V 120V 165V 55 50V 50V 50V 50V 50V 75V 75V 75V 120V 120V 165V 60 50V 50V 50V 50V 50V 75V 75V 75V 120V 120V 165V 70 50V 50V 50V 50V 50V 75V 75V 75V 120V 120V 165V 80 50V 50V 50V 50V 75V 75V 75V 120V 120V 165V 165V 90 50V 50V 50V I 75V 75V 75V 120V 120V 120V 165V 320V 100 75V 75V 75V 75V1 120V 120V 120V 165V 165V 320V 320V 110 120V 120V 120V 120V 120V 165V 165V 320V 320V 320V 1 X 120 165V 165V 165V 320V 320V 320V 320V 320V X X X (Based upon 100° F temperature rise(40° F to 140° F) X=multiple tanks required(contact your WILKINS Rep) TYPICAL INSTALLATION Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted on the cold water supply and at least 18"from the cold water inlet to the heater. Note: If incoming water pressure is above 40 psi, the precharge pressure of the expansion tank should be adjusted to equal the incoming water pressure, not to exceed 80 psi. - - TAP VALVE Hui _ILII_ _/IIS IL)QI HOSE BIBB -^ HOT WATER TSP VALVE uiNiMielt III*T HOSE II / HEATER B - MODEL STEAL MODEL BRA 1 Tr e&IIIINIM11111 ISI illiH.HEATER WATER PRESSURE MODEL 975XL REDUCING VALVE...K�l�� IIIII MODEL BRA lim'' . /Il�fn'. p 311 I�II% M DEL BR VA VEE Ipp OD I' MODEL WXTP RAIN I MF •111111111 1D IDIRECTION OF FLow III. ` DIRECTION OF FLOW �11r •. II/ RAM MODEL WXTP INSTALLATION MODEL WXTP INSTALLATION "V'SERIES SPECIFICATIONS The Water Thermal Expansion Tank shall be IAPMO® and NSF® Listed. The outer shell shall be high grade steel with exterior coating. The bladder shall be FDA approved butyl rubber and prevent water from contact with shell interior. The assembly shall incorporate a shrader valve for adjustable air precharge and a lead free bronze system connection. The Water Thermal Expansion Tank shall be a WILKINS Model WXTP. Page 2 of 2 WILKINS a Zurn Company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA:ZURN INDUSTRIES LIMITED,3544 Nashua Dr., Mississauga,Ontario L4V 1L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) • Website: http://www.zurn.com (2,01 -roLcor www.tolco.com abrand ofNlBCO Revision 5/24/2001 Fig. 23 - Hanger for CPVC Plastic Pipe Double Fastener Strap Type p Size Range— 3/4" thru 2" CPVC pipe .. _ Material — Carbon Steel, Pre-Galvanized Function — Intended to perform as a hanger/restrainer to support / • only CPVC piping used in automatic fire sprinkler systems. Can be + installed on the top or on the bottom of a beam. The Fig. 23 can also ti be installed on the side of a beam. The Fig. 23 can also function as a restrainer to prevent the upward movement of the sprinkler head 9,............1 I during activation. Approvals— Underwriters' Laboratories Listed in the USA (UL) and k. Canada (cUL) to support fire sprinkler piping. Meets and exceeds I the requirements of NFPA 13, 13R and 13D. ' B Features — Fig. 23 incorporates features which protect the pipe and ease installation. The flared edge design* protects the CPVC pipe N....T. from any rough surface. It also incorporates snap restrainers allow- ing easier and faster installation. Easily attaches to the building C B A structure using the two UL Listed hex head self threading screws** furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installa- tion tools. No impact tools (such as a hammer) or impact fasteners (such as drive screws or nails) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish — Pre-Galvanized Order By— Figure number and pipe size * Patent Pending ** Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. Dimensions •Weights CPVC Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing (Ft.) Head Size Wt./100 3/4 31/8 19/16 13/16 51/2 5/16 9 1 33/8 111/18 13/,6 6 5/16 9 11/4 43/16 23/32 13/16 61/2 5/16 11 11/2 47/,6 27/32 13/,6 7 5/16 12 2 47/8 27/16 13/16 8 5/16 15 Cffi ce/Manufacturing Faci I i ty•1375 Sampson Ave.•Cbrcna,CA 92879•Fh: 909.737.5599•Fax 909.737.0330 Customer Service•800.786.5266 39 www.tolco.com ® TDLCO www.tolco.com a brand ofNlBCO Revision 5/24/2001 Fig. 24 - Hanger for CPVC Plastic Pipe Double Fastener Strap Type Side Mount Size Range— 3/4" thru 2" CPVC pipe C Material — Carbon Steel, Pre-Galvanized , Function — Intended to perform as a hanger/restrainer to support only • . CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. The Fig. 24 can also function [ 7 as a restrainer to prevent the upward movement of the sprinkler head ! during activation. Approvals — Underwriters' Laboratories Listed in the USA (UL) and i Canada (cUL) to support fire sprinkler piping. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features— Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design* protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws** furnished with the product. It ti is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) B or impact fasteners (such as drive screws or nails) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. B A Finish — Pre-Galvanized ..0,0:,,,„,...,--'.. Order By— Figure number and pipe size * Patent Pending ** Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. Dimensions •Weights CPVC Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing (Ft.) Head Size Wt./100 3/4 25/16 15/32 13/16 51/2 5/16 9 1 25/8 15/,6 13/16 6 5/16 9 11/4 3 11/2 13/16 61/2 5/16 11 11/2 31/4 15/8 13/16 7 5/16 12 2 311/16 127/32 13/16 8 5/16 15 Main Office/Manufacturing Facility•1375 Said Ave.•Corona,Ca,92879•Fh: 909.737.5599•Fax 909.737.0330 40 Customer Servi ce•800.786.5266 www.totco.com 0TOLCO www.tolco.com a brand of NIBCO' Revision 4/27/2006 Fig. 28 u uL u5 LISTED "Stand-Off" Hanger & Restrainer for CPVC Plastic Pipe Size Range—3A" through 2" Material — Carbon Steel, Pre-Galvanized Function — Designed to be used as a hanger and restrainer for CPVC piping where the "stand-off' design will ease installation by eliminating the need for wood blocking. ` Features: • Flared edge design protects CPVC pipe from any rough or abrasive surfaces. A • Unique twist and lock design holds pipe firmly in place and allows retrofit type B of installation. • The "Stand-Off' design eliminates the need for wood block extension. C , • Can be installed on horizontal or vertical piping regardless of mounting .• .1 surface orientation. • Attaches easily to wood structure with two hex head self-threading screws furnished with product. Nit" • Installs easily using rechargeable electrical driver with 5/16" extension socket eliminating impact tool damage to pipe. • Attaches easily to steel, minimum 18 gauge with (2) 1/4" x 1" tek type self drilling tapping screws. C410.. St° • U.L. Listed as a hanger and a restrainer for fire sprinkler piping. Approvals — Underwriters' Laboratory Listed in the USA (UL) and Canada (cUL) to support automatic fire sprinkler systems. May be installed into wood using fasteners , supplied with product, or into minimum 18 gauge steel using (2) 1/4" x 1" tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28 satisfies the UL14 411111141111"-4111141111k vertical restraint requirement where needed. UL Listed as a hanger and vertical restraint when installed on 3/8" composite wood material. Use two Fig. 27B Speed Nuts when used as a hanger and restraint. Use one Fig. 27B Speed Nut on the upper installed 1 N screw when used as a hanger only. I 1 Order by— Figure number and pipe size. US AND INTERNATIONAL PATENT APPLICATION IN PROCESS. F1)I E 3 4 (1J REQUIRED FIG.27E HIGH SIDE (2J REQUIRED OF HANGER .1 I .11 1 A • . .II Ii .4*r Dimensions •Weights HANGER APPLICATION HANGER 8 RESTRAINT Pipe Approx. APPLICATION Size A B C Wt. FGI ■I■•I 3/4 31/32 2 31 .180 A — 1 35/6 23/6 31/2 .210 114 35/s 23/a 31/2 .225 lrl.71- i'_ 1Y2 4 2Y2 3� 310 FI326 ° " 2 41 211A6 3% .340 IIII FvaF ,r -■ ■■ IA .AEf JJ CFR GE/MANUFACTURING FAG UTY•1375 SQMF92N AE•OZFCINP,CA 92879•Fl-t 951.737.5599•FAX 951.737.0330 38 CLJSTCM ER SERA CE•800.786.5266 www.tolco.com ® TDLCO' www.tolco.com a brand ofNlBC❑ Revision 5/24/2001 Fig. 22C - Combination Hanger & Restrainer Application Size Range — 3/4" thru 2" CPVC pipe Material — Carbon Steel, Pre-Galvanized 518" Function — Designed to support a CPVC pipe away '—''N )11 .-•->. from the corner of a beam. This position allows for easy installation of drops or risers without adding additional "• 3 518" wood blocks. c Approvals — Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) for use as a combination hanger and ...,- TRUSS Hi=AOE R restrainer. 1 OR Finish — Pre-Galvanized — TRUSS JET Note—Approved UL Listed fastener into wood is furnished {TSP} with the product. A fastener into light gauge metal may be ordered separately. Minimum acceptable#10 x 1" hardened 4. x'3 518„ self threading screw with 5/16" hex washer head. Order By— Fig. 22C application is composed of two r >• 1 " standard Fig. 22 models—order two singles for each hanger )1.;-1)..414.,. _.,,I, and restrainer application required. eihil\ 1111P.- 1■15J8" I � >1 518- L .Q.,%;../' 0 .Ado..0..... -...., qk ) ,1 Is„.. OM Mtlilil Main Office/Manufacturing Facility•1375 Said Ave.•Corona,Ca,92879•Fh: 909.737.5599•Fax 909.737.0330 38 Customer Servi ce•800.786.5266 www.totco.com 6341.6345 SES FIRE DEPT. INLET CONN. FLUSH TYPE) CROKER SINGLE INLET An inlet connection with 250 G.P.M. minimum inlet capacity to supplement the fire protection water supply. Provides 41kli abie unobstructed water supply. Flush round design enhances r' • appearance and provides unobstructed passage. . • •k .•r STANDARD EQUIPMENT: Cast Brass round plate with double � - } female adapter; plug and chain; branding as selected. _. •'l SPECIFY THREAD AND BRANDING. v ' BRANDING: "Standpipe", "Auto Spkr." 44 FINISH: Cast Brass Figure No. 6341 Figure No. 6342 OPTIONAL FINISH: PB-Polished Brass PC-Polished Chrome Round Plate Figure No. Size 6341 2 1/2 X 2 1/2 6342 3 X 2 1/2 6343 3 X 3 RESIDENTIAL FIRE DEPT. CONNECTION An inlet connection to supplement the water supply to a ,fes residential sprinkler system. 1. ' i STANDARD EQUIPMENT: 1 1/2" cast brass round plate assembly with integral pin lug swivel inlet. Hose thread inlet _ :i N. , swivel, 1 1/2" NPT female outlet on back of plate. Cast brass plug and brass chain. Overall outside Diameter 4 3/8". SPECIFY THREAD AND BRANDING. U/L LISTED. • BRANDING: "Auto Spkr." a FINISH: Cast Brass Figure No. 6345 OPTIONAL FINISH: PB-Polished Brass PC-Polished Chrome Page 6-12 NIBCO° www.nibco.com AHEAD OF THE FLO W1' Revised 08/01/03 200 lb. WWP Bronze Check Valves Dezincification Fire Protection Valve • Horizontal Swing • Rubber Disc Resistant 200 PSI/13.8 Bar Non-Shock Cold Water • • . r { CONFORMS TO MSS SP-80 �Y MATERIAL LIST PART SPECIFICATION KT-403-W 1. Bonnet Bronze ASTM B 62 Threaded or B 584 Alloy C84400 2. Body Bronze ASTM B 62 or B 584 Alloy C84400 3. Hinge Pin Bronze ASTM B 140 Alloy C31400 or B 134 Alloy C23000 4. Disc Hanger Bronze ASTM B 62 5. Hanger Nut Bronze ASTM B 97 Alloy C65500 or Brass ASTM B 16 6. Disc Holder Bronze ASTM B 62 7. Seat Disc Buna-N(W) o TFE sA 0 8. Seat Disc Nut Brass ASTM B 16 0 or B 97 Alloy C65500 4 �q 9. Hinge Pin Plug Bronze ASTM B 140 Alloy C32000 0 o�No� (Not Shown) *10. Seat Disc Washer Stainless Steel 0 ..nON% , �., *Sizes 3/4",1",11/4"and 11/2"only. a I'IIIIIIIIII�� �-' • 111111112'/2'and 3"size only. w �r�°'- m IIIIIIIIIII��'11111iiIII� hllllu UVa 6.-veal ohmooala A DIMENSIONS-WEIGHTS-QUANTITIES KT-403-W Dimensions NPT x NPT Size A B Weight Box Master. In. mm. In. mm. In. mm. Lbs. Kg. Qty. Ctn.Qty. 1/2 15 2.44 62 1.69 43 .58 .26 10 50 3/4 20 2.94 75 1.88 48 .92 .42 10 50 1 25 3.56 90 2.31 59 1.55 .70 5 30 11/4 32 4.19 106 2.69 68 2.32 1.05 5 20 11/2 40 4.50 114 2.94 75 3.00 1.36 2 10 2 50 5.25 133 3.81 97 4.87 2.21 2 10 21/2 65 8.00 203 5.06 129 11.48 5.22 1 5 3 80 9.25 235 6.25 159 17.53 7.97 1 4 Sizes 2W and 3"supplied as T-433-Y with TFE seat disc. NIBCO check valves may be installed in both horizontal and vertical lines with upward flow or in any intermediate position. WARNING-Valve must be installed downstream of receiver tank if used in line with reciprocating air compressor. NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 14 TECH SERVICES PH:1.888.446.4226•FAX:1.800.234.0557•INTERNATIONAL OFFICE PH:+1.574.295.3221 •FAX:+1.574.295.3455 www.nibco.com WHEELOCK P1 SERIES MT AND MT STROBE ® The Symbol of Protection MULTITONE ELECTRONIC SIGNALS Wheelock's MT and MT Strobe Series Multitone Electronic Signals offer a choice of eight(8)nationally and internationally recognized alerting sounds: Horn,Bell,March Time Horn,Code-3 Tone,Code-3 Horn,Slow Whoop,Siren or Hi/Lo Tone. Wheelock's Code-3 horn and tone patterns are engineered to comply with NFPA/ANSI Temporal Pattern specifications without requiring additional coding means. With MT and MT Strobe Signals, one alarm appliance meets most of your signaling needs. Wheelock's MT and MT Strobe Signals are UL Listed, FM, CSFM and NYMEA Approved. Features • One alarm appliance with (8) eight selective signals to provide superior sound penetration for various ambient and wall conditions with two field selectable sound output ` (?L levels. F _ • Code-3 Horn and Tone meet NFPA/ANSI/ISO temporal I pattern for standard emergency evacuation signaling. tsiI 1 ill • Audible and strobe can operate from a single signaling D circuit. I` • Designed to meetorexceed NFPA/ANSI Standards and Liummi, E ADA Accessibility Guidelines. 110 VAC model does not meet ADA requirements. • Low current draw with low temperature compensation to reduce power consumption and wiring costs. • Low cost installation via standard electrical boxes. Attractive flush or surface mounting options available. MT-24-1575W-FR SHOWN I MT-121575W-FR MT 12/24 MT-24-1575W-FR* MT4-115-WH-VFR (Strobe/Horn) (Horn) (Strobe/Horn) Indoor (Strobe/Horn) Model Stock No. 1610921 Stock No. 1610914 Stock No. 1610915 Stock No. 1610216 Mounting Options** Mounting Options** Mounting Options** Mounting Options** D,E,F,L,M,O,P,R D,E,F,L,M,O,P,R D,E,F,L,M,O,P,R D,E,J,K,N,O,R dBA and Current Ratings Average Current Ratings(Amps) dBA Reverberant Ratings dBA Anechoic Ratings Per UL 464 Tone @ 24VDC @ 12VDC @ 24VDC @ 12VDC @ 12 and 24VDC HI STD HI STD HI STD HI STD HI STD Horn 0.038 0.024 0.095 0.019 92 87 90 77 99 93 Bell 0.019 0.012 0.030 0.010 86 80 85 69 92 87 March Time Horn 0.038 0.024 0.095 0.019 89 84 89 74 99 93 Code-3 Horn 0.038 0.024 0.095 0.019 88 83 88 73 99 93 Code-3 Tone 0.027 0.016 0.057 0.014 85 80 84 70 95 90 Slow Whoop 0.047 0.025 0.095 0.024 90 89 89 75 99 94 Siren 0.034 0.022 0.078 0.019 89 84 89 75 98 93 Hi/Lo 0.020 0.013 0.042 0.011 86 81 86 71 93 88 • For outdoor installation use MTWP-2475W-FR with IOB-R backbox. ** See next page for mounting options. Potter Electric Signal Company•2081 Craig Road,St.Louis,MO,63146-4161 •Phone:800-325-3936/Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8850002-REV H PAGE 1 OF 2 2/03 le WHEELOCK POTTERSERIES MT AND MT STROBE The Symbol of Protection MULTITONE ELECTRONIC SIGNALS MOUNTING ACCESSORIES (D)4"SQUARE,FLUSH(BO) (E)4"SQUARE,DEEP,FLUSH(BO) (F)DOUBLE-GANG,FLUSH(BO) 0 0 O p p p 0 0 ®o ort' Oe0 (, 0 MAXIMUM NUMBER OF,____CONDUCTORS MAXIMUM NUMBER OF CONDUCTORS MAXIMUM NUMBER OF CONDUCTORS AWG.#18 AWG.#16 AWG.#14 AWG.#12 AWG.#18 AWG.#16 AWG.#14 AWG.#12 AWG.#18 AWG.#16 AWG.#14 AWG.#12 4 4 4 4 8 8 8 4 4 4 4 4 (J)BB BACKBOX (K)WBB WEATHER RESISTANT BACKBOX (L)ISP SURFACE ADAPTER (Order Code:2830) (Order Code:2959) (Order Code:5306) Standard steel backbox with knockouts for Sturdy die-cast housing,threaded conduit hole Indoor use. interior surface mounting,concealed conduit and knockout for outdoor applications.It is mounting or semi-flush applications. It is painted to match the signal. painted to match the signal. 4 I e v —ean = LLIl_l `rrIIL} l— \ 1-02,017 'A14' n ,29/32 �i.- iO „Yma i l O V r 080O II{I •a/ lir loc.. 1 VeOMa. M.- I- �•-va- MAXIMUM NUMBER OF CONDUCTORS MAXIMUM NUMBER OF CONDUCTORS MAXIMUM NUMBER OF CONDUCTORS AWG.#18 AWG.#16 AWG.#14 AWG.#12 AWG.#18 AWG.#16 AWG.#14 AWG.#12 AWG.#18 AWG.#16 AWG.#14 AWG.#12 4 4 4 4 4 4 4 4 8 8 8 4 (0)RP-R RETROFIT PLATE (R)SFP SEMI-FLUSH PLATE (M)10B BACKBOX (Order Code:5042) (Order Code:2957) (Order Code:5046) Stamped aluminum surface wall plate which For surface mounting MT products. mounts behind the basic unit and serves to cover recessed backboxes in semi-flush mounting applications.It is painted to match '-0n I -1- 1- —'-'--1' r'n—. II 1 o 1 7[—"" the signal. dal =VS AM lir 7-.7 " �� +_ I ) .I , . epe + + I ouo 7 - UM +o 0=+ I MAXIMUM NUMBER OF CONDUCTORS DWG, 48850002-1 AWG.#18 AWG.#16 AWG.#14 AWG.#12 8 8 8 4 MOUNTING NOTES CAUTION:The mounting options figures show the maximum number of field wires(conductors)that can enter the backbox used with each mounting option.If these limits are exceeded,there may be insufficient space in the backbox to accommodate the field wires and stresses from the wires could damage the product. Although the limits shown for each mounting option comply with the National Electrical code(NEC),Wheelock recommends use of the largest backbox option and the use of approved stranded field wires whenever possible,to provide additional wiring room for easy installation and minimum stress on the product from wiring. CAUTION:Check that the installed product will have sufficient clearance and wiring room prior to installing backboxes and conduit,especially if sheathed multiconductor cable or 3/4"conduit fittings are used. 1. Mounting hardware for each mounting option is supplied. 2. Conduit entrances to the backbox should be selected to provide sufficient wiring clearance for the installed product.When extension rings are required,conduit should enter through the backbox,not the extension ring.Use Steel City#53151(1-1/2"deep)or#53171(2-1/8"deep)extension rings(as noted in the mounting options)or equivalent with the same cut-out area. 3. When terminating field wires,do not use more lead length than required.Excess lead length could result in insufficient wiring space for the appliance. 4. Use care and proper techniques to position the field wires in the backbox so that they use minimum space and produce minimum stress on the product.This is especially important for stiff,heavy gauge wires and wires with thick insulation or sheathing. 5. Do not pass additional wires(used for other than the appliance)through the backbox.Such additional wires could result in insufficient wiring space for the appliance. PRINTED IN USA MKT.#8850002-REV H PAGE 2 OF 2 2/03 122 ASHCROFT® Fire Protection, Sprinkler Service Gauge Type 1005P, XUL ASME B 40.1 Grade B (±3-2-3%of span) ▪ Underwriters Laboratory listed and Ashcroft@ fire protection sprinkler Factory Mutual approved gauges are Underwriters Laboratory •Corrosion-resistant ABScase listed and Factory Mutual approved /,'' 120 150�Ig0'1/� for fire protection sprinkler service. /%\: ▪ Heat-resistant polycarbonate The case material on Type 1005P, '90 210 ,\\ push-in window XUL gauges is ABS.The 0 300 psi =.60 240..-'...1• Patented PowerFlexTM movement pressure range is used on"wet" 270 ATEP with polyester segment systems where water is available to -30 :Ea 300 the sprinkler heads.The 0-80 retard \ ���� � ▪True ZeroTM indication, a unique to 250 psi pressure range is used on °As"`°�,o j safety feature dry systems where the lines are q93 = filled with air pressure until system activation. The patented PowerFlexi move- ment with polyester segment is designed to provide unequalled True Zero indication, a standard shock and vibration resistance feature on these gauges, reduces resulting in superior performance the potential risk of installing a dam- and extended gauge life. aged gauge on your equipment. GAUGE SPECIFICATIONS GAUGE OPTIONS Type no.: 1005P,XUL Operating Customized dials Accuracy: ASME B 40.1 Grade B temperature: —40°F to 150°F Other UL listed ranges on application (±3-2-3%of span) Connection: 'i NPT lower Size: 3/" Ranges: 0-300 psi(water) Case: ABS(Polycarbonate blend) 0-80 retard to 250 psi(air) Ring: None UL 393 Listed,UL of Canada Listed and FM approved. Window: Polycarbonate,push-in Equivalent(single or dual Dial: Black figures on white back- scale)metric scales are ground available NOTES Pointer: Black,aluminum @LISTED Bourdon tube: "C"shaped bronze Movement: Patented PowerFlex with polyester segment 4> Socket: Brass LOOK FOR THESE AGENCY MARKS ON OUR PRODUCTS Restrictor: None TO ORDER THIS TYPE 1005P,XUL GAUGE: Select: 35 W 1005 P H 02L XUL 300# 1. Dial Size:3'/E" 1 2. Patented PowerFlexfm Movement 3. Case Type Number:1005 4. Case Type Material:ABS 5. Socket Material:Brass 6. Connection Size/Location:'/NPT lower 7. UL listed,FM approved 8. Range:300 psi Consult factory for guidance in product selection ...„ii Phone(203)385-0217,Fax(203)385-0602 or DRESSER visit our web site at www.ashcroft.com Instruments CENTRAL H d . Cab . 11 -9 4 Close Sprinkler Head a ine r Central Sprinkler Company 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 Product Technical 3 , 6 & 12 Description Data Head Central Sprinkler Head Cabinets Model: Sprinkler Head Cabinet Sprinkle r are constructed of a metal enclosure Style: 3, 6 or 12 head with a hinged cover designed to HeadStandard Finish: Red enamel provide on-site storage of an emergency supply of sprinkler heads Mfgr. Source: Non-domestic and a sprinkler head wrench. Capacity: 3 sprinkler heads C a b i n e t NFPA 13 requires a representative 6 sprinkler heads number of each type of sprinkler 12 sprinkler heads head used in a sprinkler system to be Dimensions: stored in a cabinet on-site to allow for immediate removal and replacement 3 head-5"high x 7'/z"long x 2'/z"deep of sprinklers which may have 6 head-5"high x 14"long x 3'/a"deep operated or become damaged. 12 head-5"high x143/4" long x 5"deep Central Sprinkler Head Cabinets Weight: 3 head - 1.5 lbs. are manufactured of heavy gauge 6 head -2.3 lbs. steel with knock-outs to 12 head -4 lbs. accommodate either 1/2" or 3/" N.P.T. threaded sprinkler heads and are painted an attractive red enamel. They are available in three (3), six (6) or twelve (12) head capacity. No. 28-6.0 Close I nstal I at i on Care & • aderi ng Maintenance wig I of ormat i on Central's Sprinkler Head Cabinet is The Cabinet, wrench, and stock of When placing an order, indicate the designed with two%s'diameter holes spare sprinklers should be inspected full product name. Please specify the for wall mounting or direct attachment at least quarterly. The following items quantity, model, style, capacity, and to the system riser with a strap-type should be checked: size. hanger. The Cabinet should be Sprinklers, wrenches, and hard- installed at or near the system control 1. The Cabinet should be readily ware for hanging are not supplied valve and must be stocked with an accessible, and not exposed to with the Cabinet. They must be adequate supply of spare sprinklers a corrosive atmosphere or ordered separately. and a sprinkler wrench. temperatures in excess of The stock of spare sprinklers 100°F/38°C. Availability and Service: Central should include sprinklers of each type sprinklers, accessories, and other and temperature rating as are 2. The stock of spare sprinklers products are available throughout the installed in the sprinkler system, in should include an adequate U.S. and Canada, and internationally the following quantities: number of each type and through a network of Central temperature rating. Sprinkler distribution centers. You Sprinklers Spare Sprinklers may write directly to Central Sprinkler In System Required 3. The stock of sprinklers must be Company, or call (215) 362-0700 for in good condition. the distributor nearest you. under 300 6 300-1000 12 4. A sprinkler wrench of the Guarantee: Central Sprinkler over 1000 24 appropriate type must be Company will repair and/or replace included in the Cabinet. any products found to be defective in The Cabinets are designed to material or workmanship within a accept both %"and %" N.P.T. period of one year from date of threaded sprinklers. For%" N.P.T. shipment. Please refer to the current sprinklers, leave the removable Price List for further details of the knockout in the hole. For%" N.P.T. warranty. sprinklers, insert a screwdriver blade from the front top of the shelf and Conversion Table: under the near bottom part of the 1 inch = 25.400 mm knockout annular ring. Press the 1 foot = 0.3048 M screwdriver handle down to remove 1 pound = 0.4536 kg the knockout ring. The hole, with the knockout ring removed, will accept a Conversions are approximate. %" N.P.T. sprinkler. CENTRAL Central Sprinkler Company 451 North Cannon Avenue, Lansdale, PA 19446 ©1994 Central Sprinkler Company Phone(215)362-0700 Printed in U.S.A. FAX (215)362-5385 Hd.Cab.2 CENTRAL Sign 1 -9 5 Close Signs THF CO��R« AUTOMATIC 4TIC SPRIM iE S r i t For sprinkler systems & devices ;:r ' ' o.LL .1 • :I� ati'ti��• r MIN DT Mil 143.HO1µ{IQ TIL! LR711 PLII K +iT ILT .1U1 Anln • a.i.. _.1-14:,•,.• n.a.• . . •IL a a Manufactured by: Central Sprinkler Company •• 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 P Main prn Product sprinkler sprinkler control 11 Desc• ion Open sprinkler drain Identification Test valve Triangular main drain Signs Water motor Central's Identification Signs are Water motor line designed to provide information to the end user about the sprinkler system Techni cal and it's components. They are available with a variety of wording Data to meet the signing requirements of NFPA 13. The five basic types of signs are as Model: Sign follows: Style: Flat, rectangular Type A- Control Valve Sign Standard Finish: porcelain or mylar Type B - Multi-purpose Text Signs Size: Type A- 9" x 7" Type C - Cold Weather Sign Type B - 6" x 2" Type D - Fire Alarm Sign Type C- 73/a" x 1'/a" Type E - Hydraulic Calculation Sign Type D -9" x 7" The Signs are constructed of 18 Type E - 5" x 7" gauge steel or aluminum with a Weight: Type A-4.5 oz. porcelain enamel or printed mylar Type B - 0.5 oz. facing respectively. The signs have Type C-2.0 oz. corner holes or slots for easy attach- ment in the field. Type D -4.0 oz. Sign Type B is available with the Type E - 1.5 oz. following text options: Air control Installation Air control valve Air line Alarm test Alarm line Antifreeze system The Identification Signs are pro- Auxiliary drain vided with 1/8" diameter or larger holes Control (or slots) in the corners for easy Control valve attachment using standard hardware Drain chain, wire, plastic lock ties, or light Drain valve gauge metal strap (not included). Entire system From city main In this building In this section Inspectors test Main control No. 28-9.0 Close Sign -Type A Sign -Type D k Q"Cer i ng • • THIS VALVE CONTROLS SUPPLY AUTOMATIC SPRI NIQERS SPRINKLERa4I reformat i on TO ' FIRE - ALARM rill • • When placing an order, indicate MUST OPEN AT ALL WHEN BELL RINGS BE TIMES the full product name. Please TO BE HANDLED ONLY BY AUTHORIZED PERSON OR CALL specify the quantity and type. BY EMPLOYEE CARING FOR SPRINKLER SYSTEM IN CASE OF FIRE FIRE DEFT OR POLICE Hardware for hanging is not DO NOT SHUT VALVE UNTIL FIRE IS ENTIRELY OUTil supplied with the Sign. It must be WHEN VALVE IS SHUT FOR EMERGENCY-REPAIRS-OR FIRE- ordered separately. NOTIFY: .r Availability and Service: REQUEST DIRECTIONS--RESTORE PROTECTION QUICKLY Central sprinklers, accessories, and other products are available The blank spaces on this sign may throughout the U.S. and Canada, be utilized to provide message and internationally through a flexibility. Simply add combinations of Sign -Type E network of Central Sprinkler sign Type B and Type C as desired. • HYDRAULIC-SYSTEM • distribution centers. You may This Building is Protected by a write directly to Central Sprinkler Sign -Type B Hydraulically Designed Automatic Company, or call (215) 362-0700 Sprinkler System • • for the distributor nearest you. AUXILIARY DRAIN Location Guarantee: Central Sprinkler No. of Sprinklers Company will repair and/or • • replace any products found to be Basis of Design defective in material or 1.DENSITY GPM/SQ.FT. workmanship within a period of Sign -Type C 2 DESIGNED AREA OF DISCHARGE SQ.FT. one year from date of shipment. System Demand Please refer to the current Price FRONT List for further details of the • • 1.WATER FLOW RATE GPM VALVE 2.RESIDUAL PRESSURE AT THE PSI warranty. VALVE MUST BE OPENED IN CASE OF FIRE BASE OF THE RISER SHUT ALSO DURING SUMMER MONTHS SHUT Conversion Table: • • 1 inch = 25.400 mm BACK 1 foot = 0.3048 M • 1 pound = 0.4536 kg AND MUST BE KEPT OP EN EXCEPT DURING WINTER MONTHS, `conversions are approximate. WHEN VALVE IS TO BE CLOSED AND PIPES DRAINED. CENTRAL _,..„ Central Sprinkler Company 451 N. Cannon Avenue, Lansdale, PA 19446 ©1995 Central Sprinkler Company Phone (215)362-0700 Printed in U.S.A. FAX (215) 362-5385 Signs.1 1LE - , DthGNGP4 . ' P 5151 Bannock k5t . Denver, CO 8021 : 303 -291401 31. 3 - 383 - 5023 F firesprjnkler@afssco . com A FIkE SPRINKLER DESIGN COMPANY