Loading...
HomeMy WebLinkAboutF14-0069_RITZ FP-1_1414101600.pdf39X80 PLUG 83x88 38x24 34x19 61.25x22-5/8 81X89 48x19 24x13 81.5 X 88 72x19.8 24x13 18x18 OUTSIDE PATIO OUTSIDE PATIO AREA PROTECTED FROM ABOVE CAP/REROUTE BRANCHLINES HERE PLUG PLUG THIS SET OF FIRE SPRINKLER SHOP DRAWINGS HAVE BEEN REVIEWED AND FOUND TO BE ACCEPTABLE BY TIMOTHY N. TROSTEL, JR - N.I.C.E.T. IV # 102055. SR. ENGINEERING TECHNICIAN - FIRE PROTECTION NATIONAL INSTITUTE FOR CERTIFICATION IN ENGINNERING TECHNOLOGIES ____________________________________/____/____ ACCEPTING THIS COPY IS DEEMED AS AGREEING TO THE FOLLOWING: THIS DRAWING COPY, ITS CONTENTS, INFORMATION AND PRINCIPALS OF DESIGN ARE THE EXCLUSIVE PROPERTY OF THE FIRE PROTECTION CONTRACTOR LISTED AND MILE HIGH DESIGN GROUP, LLC AND IS BEING SUBMITTED TO YOU WITH THE UNDERSTANDING THAT IT IS NOT TO BE REPRODUCED, COPIED OR MODIFIED IN ANY MANNER; NEITHER SHALL IT BE RELAYED IN WHOLE OR IN PART TO ANY OTHER INDIVIDUAL OR FIRM FOR ANY OTHER PROJECT OR EXTENSION OF THIS PROJECT EXCEPT THRU WRITTEN AGREEMENT WITH THE FIRE PROTECTION CONTRACTOR AND MILE HIGH DESIGN GROUP, LLC. ERRORS AS A RESULT OF THIS FILE BEING ELECTRONICALLY TRANSMITTED ARE BEYOND THE CONTROL OF AND ARE NOT THE RESPONSIBILITY OF THE FIRE PROTECTION CONTRACTOR OR MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR INSTALLATION OR INSPECTION OF WORK INSTALLED. THESE PLANS ARE DIAGRAMMATICAL ONLY. ON SITE COORDINATION MUST BE ARRANGED WITH ALL OBSTRUCTIONS, i.e.: MECHANICAL, ELECTRICAL, AND STRUCTURAL. ANY ALTERATIONS FROM ENGINEERED DRAWINGS MUST BE APPROVED BY MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR LAYOUT DESIGN ISSUES OR CONFLICTS WITH ANY OBSTRUCTIONS. IF ADDITIONAL FIRE SPRINKLER PIPING AND/OR FIRE SPRINKLER HEADS ARE REQUIRED THIS WILL BE THE RESPONSIBILITY OF THE FIRE SPRINKLER CONTRACTOR. ALL CHANGES MUST ME APPROVED BY MILE HIGH DESIGN GROUP, LLC THE OWNER IS RESPONSIBLE TO PROVIDE SUFFICIENT HEAT THROUGHOUT THIS BUILDING TO PREVENT FREEZING OF WATER IN THE FIRE SPRINKLER SYSTEM - GENERAL NOTES PER NFPA 13, 2010 EDITION ALL FIRE SPRINKLER MAIN PIPING ARE TO BE SCH 10 OR EQUIVALENT. BRANCH LINES ARE TO BE SCH 10 AND SCH 40 OR EQUIVALENT. ARMOVERS AND DROPS/SPRIGS ARE TO BE SCH 40 OR EQUIVALENT. OUTLETS TO BE WELD-O-LETS FOR THE FIRE SPRINKLER HEADS AND PIPE OUTLETS HANGERS TO CONFORM TO NFPA 13 FOR SPACING AND PIPE TO BE SUPPORTED BY RING HANGER AND (3/8" FOR 1 ~ 4 INCH) AND (1/2" FOR 6 ~8 INCH) ALL THREAD ROD WITH ATTACHING DEVICE (BEAM CLAMP, SAMMY SCREW OR HILTI DROP-IN) START POINT OF WORK TO BE FROM THE EXISTING FIRE SPRINKLER SYSTEM ALL FIRE SPRINKLER HEAD RELOCATED WILL BE REPLACED WITH NEW HEADS TO MATCH THE EXISTING HEADS IN THE AREA OF WORK THIS AREA IS ALL RESIDENTIAL - MAX SPRINKLER SPACING 16'X16' AND NO FURTHER THAN 8'-0" OFF ANY WALL AND NO CLOSER THAN 8'-0" FROM ANOTHER SPRINKLER 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Approved for permit Vail Fire & Emergency Services 10/23/14