Loading...
HomeMy WebLinkAboutF15-0008_F15-0008 cut sheets_1425655740.pdfTHOMPSON/GARRIGA UNIT 250, VILLA CORTINA VAIL, CO 81657 EQUIPMENT SUBMITTAL 9/4/2014 CORPORATION 57 HEREFORD LANE EDWARDS, CO 81632 PH: (970) 914-5014 Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Flat-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems Page 1 of 6 APRIL 2013 TFP443 Worldwide Contacts www.tyco-fire.com General Description The TYCO RAPID RESPONSE Series LFII Residential Flat-Plate Concealed Pendent Sprinklers (TY2524) are decora-tive, fast response, fusible solder sprin-klers designed for use in residential oc-cupancies such as homes, apartments, dormitories, and hotels. The Cover Plate/Retainer Assembly con-ceals the sprinkler operating compo-nents above the ceiling. The flat profile of the Cover Plate provides the optimum aesthetically appealing sprinkler design. Additionally, the concealed design of the Series LFII Residential Flat-Plate Con-cealed Pendent Sprinklers provides 1/2 inch (12,7 mm) vertical adjustment. This adjustment provides a measure of flex-ibility when cutting fixed sprinkler drops. The Series LFII Residential Flat-Plate Concealed Pendent Sprinklers are in-tended for use in the following systems: • wet and dry pipe residential sprin-kler systems for one- and two-fam-ily dwellings and mobile homes per NFPA 13D • wet and dry pipe residential sprin-kler systems for residential occu-pancies up to and including four sto-ries in height per NFPA 13R • wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 The Series LFII Residential Sprinklers have been designed with heat sensitiv-ity and water distribution characteristics proven to help in the control of residen- tial fires and to improve the chance for occupants to escape or be evacuated. The Series LFII Residential Flat-Plate Concealed Pendent Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap protects the sprinkler during ceiling installation or finish. After ceiling installation is com-plete, the Protective Cap is removed and the Cover Plate/Retainer Assem-bly is installed. Removing the Protec-tive Cap is required for proper sprinkler performance. Dry Pipe System ApplicationThe Series LFII Residential Flat-Plate Concealed Pendent Sprinkler offers a laboratory approved option for design-ing dry pipe residential sprinkler sys-tems, whereas, most residential sprin-klers are laboratory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Flat-Plate Con-cealed Sprinklers (TY2524) need not be increased over the number of design sprinklers (hydraulic design area) speci-fied for wet pipe sprinkler systems, as is customary for density/area sprinkler systems designed per NFPA 13, 13D, or 13R. Consequently, the Series LFII Residen-tial Flat-Plate Concealed Sprinklers (TY2524) offer the features of non-wa-ter filled pipe in addition to not having to increase the number of design sprinklers (hydraulic design area) for systems de-signed to NFPA 13, 13D, or 13R. Non-water filled pipe will permit options for areas sensitive to freezing. NOTICE The Series LFII Residential Flat-Plate Concealed Pendent Sprinklers (TY2524) described herein must be installed and maintained in compliance with this doc-ument and the applicable standards of the National Fire Protection Association, in addition to the standards of any au-thorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain-ing their fire protection system and de-vices in proper operating condition. The installing contractor or sprinkler manu-facturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY2524 IMPORTANTAlways refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal-lation of sprinkler systems and com-ponents. Improper handling and in-stallation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. TFP443Page 2 of 6 3-3/16" DIA.(81,0 mm) 1/2"NPT 2-1/2" DIA. (63,5 mm) MOUNTING SURFACE3/16"(4,8 mm) 1/8" GAP(3,2 mm) FACE OFSPRINKLERFITTING 7/8" (22,2 mm) 1-1/8" (28,6 mm) TIP DEFLECTOR INOPERATED POSITION 1/2" (12,7 mm)THREADEDADJUSTMENT SPRINKLER- SUPPORT CUP ASSEMBLY OPERATED SPRINKLER 1-7/8"±1/4"(47,6 mm±6,4 mm) SPRINKLER- SUPPORT CUP ASSEMBLY COVER- RETAINER ASSEMBLY COVER PLATE RETAINER DISPOSABLEPROTECTIVE CAP SPRINKLER/SUPPORT CUP ASSEMBLY COVER PLATE/RETAINER ASSEMBLY COVER PLATE EJECTION SPRING RETAINER WITH THREAD DIMPLES SOLDER TAB SEALINGASSEMBLY COMPRESSION SCREW DEFLECTOR(OPERATEDPOSITION) SPRINKLERWRENCHINGAREA SOLDER LINK ELEMENT LEVER DEFLECTOR CAP BODY(1/2" NPT) SADDLE SUPPORTCUP WITHROLL FORMEDTHREADS GUIDEPIN GUIDE PIN HOUSING THREAD INTO SUPPORT CUP UNTIL MOUNTING SURFACE IS FLUSH WITH CEILING WRENCHRECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 RAPID RESPONSE SERIES LFII RESIDENTIAL FLAT-PLATE (TY2524) INSTALLATION DIMENSIONS/PROTECTIVE CAP/ACTIVATED DEFLECTOR FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL FLAT-PLATE CONCEALED PENDENT SPRINKLER (TY2524) FIGURE 2 W-TYPE 18 SPRINKLER WRENCH TFP443 Page 3 of 6 Technical Data ApprovalsUL and C-UL Listed The TYCO RAPID RESPONSE Series LFII Residential Flat-Plate Concealed Pendent Sprinklers are only listed with the Series LFII Concealed Cover Plates having a factory-applied finish. For details on approvals, refer to the De-sign Criteria section. Maximum Working Pressure175 psi (12,1 bar) Discharge CoefficientK=4.9 GPM/psi1/2 (70,6 LPM/bar1/2) Temperature RatingSprinkler: 160°F (71°C) Cover Plate: 139°F (59°C) Vertical Adjustment1/2 inch (12,7 mm) FinishesRefer to the Ordering Procedure section. Physical CharacteristicsCover Plate/Retainer Assembly:Cover Plate . . . . . . . . . . . . . CopperEjection Spring ....Stainless SteelRetainer ................Brass Sprinkler/Support Cup Assembly:Body ...................Brass Cap ...................Bronze Saddle . . . . . . . . . . . . . . . . . . Brass Sealing Assembly . . . . . . .Beryllium Nickel w/ TEFLON Soldered Link Halves . . . . . . NickelLever ..................BronzeCompression Screw . . . . . . . BrassDeflector . . . . . . . . . . . . . . . BronzeGuide Pin Housing........BronzeGuide Pins .............BronzeSupport Cup . . . . . . . . . . . . . . Steel Operation When exposed to heat from a fire, the Cover Plate, which is normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup As-sembly. At this point, the Deflector, sup-ported by the Guide Pins, drops down to its operated position. The Solder Link Element of the Sprinkler/Support Cup Assembly is comprised of two link halves that are soldered togeth-er with a thin layer of solder. When the rated temperature is reached, the sol-der melts and the two link halves sepa-rate, allowing the sprinkler to activate and flow water. Design Criteria The TYCO RAPID RESPONSE Series LFII Residential Flat-Plate Concealed Pendent Sprinklers (TY2524) are UL and C-UL Listed for installation in ac-cordance with this section: Residential Sprinkler Design GuideWhen conditions exist that are outside the scope of the provided criteria, re-fer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that may be accept-able to the authority having jurisdiction. System TypePer the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 about the use of Residential Sprinklers in residential dry pipe systems. Ceiling TypesSmooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R or 13 as applicable. Hydraulic Design (NFPA 13D and 13R)For systems designed to NFPA 13D or NFPA 13R, the minimum required sprin-kler flow rate are given in Tables A and B as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the mini-mum required discharge from each of the total number of “design sprinklers” as specified in NFPA 13D or NFPA 13R. The number of “design sprinklers” spec-ified in NFPA 13D and 13R for wet pipe systems is to be applied when designing dry pipe systems. Hydraulic Design (NFPA 13)For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis-charge from each of the four sprinklers is to be the greater of the following: • The flow rates given in Tables A and B as a function of temperature rating and the maximum allowable cover-age area • A minimum discharge of 0.1 gpm/ft2. over the “design area” comprised of the four most hydraulically demand-ing sprinklers for the actual coverage areas being protected by the four sprinklers The number of “design sprinklers” specified in NFPA 13 for wet pipe sys-tems is to be applied when designing dry pipe systems. Dry Pipe System Water DeliveryWhen using the Series LFII Residential Flat-Plate Concealed Pendent Sprinklers (TY2524) in dry pipe sprinkler systems, the time for water delivery must not ex-ceed 15 seconds for the most remote operating sprinkler. Obstruction to Water Distribution.Sprinklers are to be located in accor-dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational SensitivityInstall sprinklers relative to the ceiling mounting surface as shown in Figure 3. The Series LFII Residential Flat-Plate Concealed Pendent Sprinklers must not be used in applications where the air pressure above the ceiling is greater than that below. Down drafts through the Support Cup can delay sprinkler op-eration in a fire situation. Sprinkler SpacingThe minimum spacing between sprin-klers is 8 feet (2,4 m). The maximum spacing between sprinklers cannot ex-ceed the length of the coverage area (Table A) being hydraulically calculated (e.g., a maximum of 12 feet for a 12 ft. x 12 ft. coverage area or 20 feet for a 20 ft. x 20 ft. coverage area.) TFP443Page 4 of 6 Maximum Coverage Area (a) Ft. x Ft. (m x m) Maximum Spacing Ft. (m) WET PIPE SYSTEM Minimum Flow and Residual Pressure(b, c) Ordinary Temp Rating 160°F (71°C)Deflector to Ceiling Installation Type Minimum Spacing Ft. (m) Flow GPM (L/min) Pressure PSI (bar) 12 x 12(3,7 x 3,7)12(3,7)13 (49,2)7.0 (0,48)Smooth Ceilings 7/8 to 1-1/8 inches. Beamed Ceilings per NFPA 13D 13R, or 13 Installed in beam 7/8 to 1-1/8 inches below bottom of beam Concealed 8 (2,4) 14 x 14(4,3 x 4,3)14(4,3)13 49,2)7.0 (0,48) 16 x 16(4,9 x 4,9)16(4,9)13(49,2)7.0 (0,48) 18 x 18(5,5 x 5,5)18(5,5)17 (64,3)12.0 (0,83) 20 x 20(6,1 x 6,1)20(6,1)20 (75,7)16.7 (1,15) (a) For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which Hydraulic Design section under the Design Criteria are stated. (b) The Minimum Flow requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pres- sures are calculated using the nominal K-factor. Refer to “Hydraulic Design” in the Design Criteria section for details. (c) For NFPA 13 residential applications, the greater of 0.1 gpm/ft.2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL FLAT-PLATE CONCEALED PENDENT SPRINKLER (TY2524) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA Maximum Coverage Area (a) Ft. x Ft. (m x m) Maximum Spacing Ft. (m) DRY PIPE SYSTEM Minimum Flow and Residual Pressure(b) Ordinary Temp Rating 160°F (71°C)Deflector to Ceiling Installation Type Minimum Spacing Ft. (m) Flow GPM (L/min) Pressure PSI (bar) 12 x 12(3,7 x 3,7)12(3,7)15 (56,8)9.4 (0,65)Smooth Ceilings 7/8 to 1-1/8 inches. Beamed Ceilings per NFPA 13D 13R, or 13 Installed in beam 7/8 to 1-1/8 inches below bottom of beam Concealed 8 (2,4) 14 x 14(4,3 x 4,3)14(4,3)15 (56,8)9.4 (0,65) 16 x 16(4,9 x 4,9)16(4,9)16 (60,6)10,7 (0,74) 18 x 18(5,5 x 5,5)18(5,5)17 (64,3)12.0 (0,83) 20 x 20(6,1 x 6,1)20(6,1)21 (79,5)18,4 (1,27) (a) For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which Hydraulic Design section under the Design Criteria are stated. (b) The Minimum Flow requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to “Hydraulic Design” in the Design Criteria section for details. (c) For NFPA 13 residential applications, the greater of 0.1 gpm/ft.2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM SERIES LFII RESIDENTIAL FLAT-PLATE CONCEALED PENDENT SPRINKLER (TY2524) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TABLE A WET PIPE SYSTEMSSERIES LFII (TY2334) RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS NFPA 13D, 13R AND 13 WET PIPE HYDRAULIC DESIGN CRITERIA Max. Coverage Area (a) Width x Length (d) Ft. x Ft. (m x m) Max. Spacing Ft. (m) WET PIPE SYSTEM Minimum Flow and Residual Pressure(b, c) Ordinary Temp. Rating 155°F (68°C) Intermediate Temp. Rating 175°F (79°C)Deflector to Ceiling Installation Type Minimum Spacing Ft. (m) Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3,7 x 3,7)12 (3,7)13 (49,2)8.7 (0,60)13 (49,2)8.7 (0,60) 4 to 6 inches Recessed using Style 20 Escutcheon or non-recessed per NFPA 13D, 13R, or 13 8(2,4) 14 x 14 (4,3 x 4,3)14 (4,3)14 (53,0)10.1 (0,70)14 (53,0)10.1 (0,70) 16 x 16 (4,9 x 4,9)16 (4,9)16 (60,6)13.2 (0,91)16 (60,6)13.2 (0,91) 16 x 18 (4,9 x 5,5)16 (4,9)19 (71,9)18.6 (1,28)19 (71,9)18.6 (1,28) 16 x 20 (4,9 x 6,1)16 (4,9)23 (87,1)27.3 (1,88)23 (87,1)27.3 (1,88) 18 x 18 (5,5 x 5,5)18 (5,5)23 (87,1)27.3 (1,88)23 (87,1)27.3 (1,88) 18 x 20 (5,5 x 6,1)18 (5,5)26 (98,4)34.9 (2,41)26 (98,4)34.9 (2,41) 12 x 12 (3,7 x 3,7)12 (3,7)13 (49,2)8.7 (0,60)13 (49,2)8.7 (0,60) 6 to 12 inches 14 x 14 (4,3 x 4,3)14 (4,3)14 (53,0)10.1 (0,70)14 (53,0)10.1 (0,70) 16 x 16 (4,9 x 4,9)16 (4,9)17 (64,3)14.9 (1,03)17 (64,3)14.9 (1,03) 16 x 18 (4,9 x 5,5)16 (4,9)20 (75,7)20.7 (1,43)20 (75,7)20.7 (1,43) 16 x 20 (4,9 x 6,1)16 (4,9)23 (87,1)27.3 (1,88)23 (87,1)27.3 (1,88) 18 x 18 (5,5 x 5,5)18 (5,5)23 (87,1)27.3 (1,88)23 (87,1)27.3 (1,88) 18 x 20 (5,5 x 6,1)18 (5,5)26 (98,4)34.9 (2,41)26 (98,4)34.9 (2,41) (a) For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. (c) For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area or the flow in accordance with the criteria in this table must be used. (d) The Width x Length dimension refers to the Width (backwall where the sprinkler is located) times the Length (horizontal throw of sprinkler). TFP412Page 4 of 6 A H E A D O F T H E F L O W ® www.nibco.com NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 4 All of the advantages found in copper as a metal have been capitalized to the utmost in the manufacture of NIBCO Fittings. Because of the accuracy of construc tion and design, copper plumbing is more efficient and less expensive. NIBCO manufactures nine general types of fittings: Wrot Pressure; Cast Pressure; Wrot Drainage; Cast Drainage; Flanges; Flared Tube; Threaded Bronze; Insert Fittings for PEX; Barbed Insert Fittings for Polybutylene. Each has its particular place and use and each offers its own advantages when used for the proper service requirement. ALLOY AND FINISH — NIBCO Fittings are made from highest quality raw materials available — Cast Fittings are made from Copper Alloy C84400 which consists of 81% Copper, 7% Lead, 3% Tin, and 9% Zinc per ASTM Specification B584. Wrot Copper Fittings are made from commercially pure copper mill products per ASTM Specifications B75 Alloy C12200. NIBCO fittings are produced to meet requirements of applicable standards wherever practicable. NIBCO brand wrot and cast fittings are manufactured in the U.S.A. and Mexico. The manufacturing plants at Stuarts Draft, VA, Nacogdoches, TX and Reynosa, Mexico are registered to ISO 9002 quality standards. Following is suggested phrasing to be incorporated in your specifications or bills of material for Copper Tube Fittings. WROT SOLDER JOINT FITTINGS — “Wrot Solder Joint Fittings shall be produced to one of the following specifications: 1. Material and workmanship shall be in accordance with ASME/ANSI B16.22; Wrought Copper and Copper Alloy Solder Joint Pressure Fittings.” Specifications 2. The dimensional, material and workmanship shall meet the requirements of MSS SP-104; Wrought Copper Solder Joint Pressure Fittings.” 3. The dimensional, material and workmanship of 5"–12" copper fittings shall meet the requirements of MSS SP-109 “Welded Fabricated Copper Solder Joint Pressure Fittings.” 4. Certified to ANSI/NSF 61. CAST COPPER ALLOY SOLDER JOINT FITTINGS — “Cast Copper Alloy Solder Joint Fittings shall be in accor dance with ANSI Std. B16.18.” WROT DRAINAGE FITTINGS — “Wrot Drainage Fittings shall be in accordance with ASME/ANSI Std. B16.29.” CAST COPPER ALLOY SOLDER JOINT DRAINAGE FITTINGS — “Cast Copper Alloy Solder Joint Drainage Fittings shall be in accordance with ASME Std. B16.23.” CAST COPPER ALLOY FLARED TUBE FITTINGS — “Cast Copper Alloy Flared Tube Fittings shall be in accor- dance with ASME/ANSI Std. B16.26. CAST COPPER ALLOY FLANGES AND FLANGED FITTINGS— CLASS 150 — Cast Copper Alloy Flanges and Flanged Fittings shall meet the requirements of MSS SP-106 and/or the workmanship and dimensions of Federal Specifications WW-F-406 or ASME Std. B16.24. CLASS 125 — Material, workmanship and dimensions of flanges shall be in accordance with MSS SP-106. CAST BRONZE THREADED FITTINGS — “Cast Bronze Threaded Fittings shall be in accordance with ANSI/ASME B16.15.” POLYBUTYLENE COPPER INSERT TYPE VALVES AND FITTINGS — “Wrot Copper Insert Fittings shall be manufactured per the following specifications: MSS SP-103 or ASTM F1380.” NIBCO Copper Tube Fittings are all produced to above Standards. To simplify, write your specifications to read: “Copper Tube Fittings to be in accordance with specifications as outlined in NIBCO Catalog c-cf-0602.” WROT COPPER MEDICAL MEDICAL GAS SYSTEM COMPONENTS — Wrot copper fittings that are to be installed in medical gas applications shall be prepared in accordance with NFPA 99, Health Care Facilities Gas and Vacuum Systems and the Compressed Gas Association, Pamphlet G4.1. Packaging shall be adequately protective and include labeling that identifies the preparer and states that the product has been cleaned and bagged for oxygen or med gas service. For technical information and dimensions refer to the engineering section contained in this catalog. Revision 3/29/04 A H E A D O F T H E F L O W ® www.nibco.com NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 6 703-2 Fitting Adapter Ftg x F – Cast APPROX. DIM. B NOM. SIZE NET WT./LBS. INCHES 1/2 x 1/4 0.11 17/32 3/4 x 1/2 0.12 19/16 1 x 3/4 0.38 131/32 1 x 1/2 0.15 17/16 2 1/2 1.65 215/16 3 2.47 31/4 703-5 Special Drop Adapter C x F – Cast APPROX. DIM. A NOM. SIZE NET WT./LBS. INCHES 1/2 0.16 3/4 3/4 0.24 31/32 703-5B Drop Adapter C x F – Cast APPROX. DIM. A NOM. SIZE NET WT./LBS. INCHES 1/2 0.15 3/4 ADAPTERS 603 Adapter C x F – Wrot APPROX. DIM. A NOM. SIZE NET WT./LBS. INCHES 1/8 0.03 13/32 1/8 x 1/4 0.03 1/2 1/4 0.03 5/8 1/4 x 3/8 0.05 21/32 3/8 0.04 11/16 3/8 x 1/2 0.09 29/32 3/8 x 1/4 0.03 9/16 1/2 0.09 27/32 1/2 x 3/4 0.14 1 1/2 x 3/8 0.04 17/32 1/2 x 1/4 0.05 1/2 5/8 x 3/4 0.12 29/32 5/8 x 1/2 0.11 3/4 3/4 0.15 29/32 3/4 x 1 0.21 11/8 3/4 x 1/2 0.10 5/8 1 0.24 31/32 1 x 1 1/4 0.28 17/32 1 x 3/4 0.19 25/32 1 x 1/2 0.24 5/8 1 1/4 0.33 13/32 1 1/4 x 1 1/2 0.40 11/4 1 1/4 x 1 0.27 31/32 1 1/2 0.44 11/8 1 1/2 x 2 0.50 11/32 2 0.63 13/32 2 x 1 1/2 0.74 13/16 2 1/2 1.13 – 3 1.94 – 703 Adapter C x F – Cast APPROX. DIM. A NOM. SIZE NET WT./LBS. INCHES 1/4 x 1/2 0.13 27/32 1/2 x 1 0.30 1 3/4 x 1 1/4 0.55 11/8 3/4 x 3/8 0.17 3/4 1 x 1 1/2 0.68 13/32 1 1/4 x 1 0.27 31/32 1 1/4 x 3/4 0.29 3/4 1 1/2 x 2 0.78 11/32 1 1/2 x 1 0.37 25/32 1 1/2 x 1 1/4 0.47 11/4 2 x 1 1/4 0.76 27/32 2 1/2 1.62 13/8 3 2.34 11/2 4 4.05 19/16 603-2Fitting Adapter Ftg x F – Wrot APPROX. DIM. B NOM. SIZE NET WT./LBS. INCHES 1/4 0.03 13/32 3/8 0.06 13/16 1/2 0.09 17/16 1/2 x 3/8 0.05 11/4 3/4 0.13 111/16 1 0.27 21/32 1 1/4 0.31 21/8 1 1/2 0.43 25/16 2 0.61 217/32 Consult price sheet for Made to Order items and for minimum order quantities. Revision 2/6/07 A H E A D O F T H E F L O W ® www.nibco.com NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 9 Consult price sheet for Made to Order items and for minimum order quantities. CAPS 617 Tube Cap C – Wrot APPROX. DIM. N NOM. SIZE NET WT./LBS. INCHES 1/8 0.01 1/32 1/4 0.01 3/32 3/8 0.01 3/32 1/2 0.02 3/32 5/8 0.03 1/8 3/4 0.04 1/8 1 0.07 5/32 1 1/4 0.10 3/32 1 1/2 0.16 1/8 2 0.27 5/32 2 1/2 0.50 7/32 3 0.78 7/32 4 1.66 1/4 717 Tube Cap C – Cast APPROX. DIM. N NOM. SIZE NET WT./LBS. INCHES 5 5.48 7/16 6 9.07 17/32 717-D Drain Cap – Cast APPROX. DIM. A NOM. SIZE NET WT./LBS. INCHES 1/2 0.06 21/32 COUPLINGS 600 Reducing Coupling C x C – Wrot APPROX. DIM. A NOM. SIZE NET WT./LBS. INCHES 1/8 x 3/16 O.D. 0.01 5/32 5/16 O.D. x 1/8 0.01 3/16 1/4 x 5/16 O.D. 0.01 3/16 1/4 x 1/8 0.01 3/16 3/8 x 1/4 0.02 3/16 3/8 x 5/16 O.D. 0.01 1/4 3/8 x 1/8 0.01 1/4 1/2 x 3/8 0.03 3/16 1/2 x 1/4 0.02 1/4 1/2 x 1/8 0.03 11/32 5/8 x 1/2 0.05 3/16 5/8 x 3/8 0.04 11/32 5/8 x 1/4 0.03 13/32 3/4 x 5/8 0.07 3/16 3/4 x 1/2 0.06 9/32 3/4 x 3/8 0.06 3/8 3/4 x 1/4 0.05 11/32 1 x 3/4 0.11 11/32 1 x 5/8 0.09 3/8 1 x 1/2 0.10 11/32 1 x 3/8 0.10 13/32 1 1/4 x 1 0.16 5/16 1 1/4 x 3/4 0.18 17/32 1 1/4 x 5/8 0.18 5/8 1 1/4 x 1/2 0.14 7/16 1 1/2 x 1 1/4 0.23 5/16 1 1/2 x 1 0.22 9/16 1 1/2 x 3/4 0.20 3/8 1 1/2 x 1/2 0.19 1/2 2 x 1 1/2 0.41 9/16 2 x 1 1/4 0.35 11/16 2 x 1 0.37 7/16 2 x 3/4 0.34 17/32 2 x 1/2 0.35 23/32 2 1/2 x 2 0.59 9/16 2 1/2 x 1 1/2 0.65 11/16 2 1/2 x 1 1/4 0.65 13/16 2 1/2 x 1 0.73 29/32 Continues… APPROX. DIM. A NOM. SIZE NET WT./LBS. INCHES 3 x 2 1/2 0.98 1/2 3 x 2 1.06 15/16 3 x 1 1/2 0.92 11/32 3 1/2 x 3 1.52 1/2 4 x 3 1/2 2.12 19/32 4 x 3 1.92 27/32 4 x 2 1/2 1.77 1 4 x 2 1.92 11/4 5 x 4 3.50 331/32 5 x 3 3.18 115/32 5 x 2 1/2 3.50 13/16 5 x 2 3.09 21/32 6 x 5 5.70 11/8 6 x 4 5.24 11/2 6 x 3 5.04 2 6 x 2 1/2 5.13 21/4 6 x 2 4.89 21/2 8 x 6 13.06 119/32 8 x 4 12.22 219/32 8 x 3 11.79 33/32 8 x 2 1/2 12.64 33/8 600-RS Coupling with Rolled Tube Stop C x C – Wrot APPROX. DIM. A NOM. SIZE NET WT./LBS. INCHES 1/8 O.D. 0.01 1/16 3/16 O.D. 0.01 3/32 1/8 0.01 1/16 5/16 O.D. 0.01 3/32 1/4 0.01 1/16 3/8 0.01 3/32 1/2 0.03 3/32 5/8 0.04 3/32 3/4 0.06 3/32 7/8 0.09 3/32 1 0.11 3/32 1 1/4 0.16 1/8 1 1/2 0.23 1/8 2 0.41 1/8 2 1/2 0.65 1/8 3 0.93 1/8 3 1/2 1.45 5/32 4 1.93 7/32 Revision 2/6/07 A H E A D O F T H E F L O W ® www.nibco.com NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 12 ELBOWS continued Consult price sheet for Made to Order items and for minimum order quantities. 706-2 45° Fitting Elbow Ftg x C – Cast APPROX. DIM. B DIM. C NOM. SIZE NET WT./LBS. INCHES INCHES 4 4.31 311/32 15/16 607 90° Elbow – Close Rough C x C – Wrot APPROX. DIM. C DIM. D NOM. SIZE NET WT./LBS. INCHES INCHES 1/8 0.01 13/32 13/32 1/4 0.02 9/32 9/32 3/8 0.03 1/2 1/2 1/2 0.04 3/8 3/8 1/2 x 3/8 0.04 9/16 21/32 3/4 0.10 17/32 17/32 3/4 x 5/8 0.12 29/32 7/8 3/4 x 1/2 0.10 17/32 3/4 1 0.21 23/32 23/32 1 x 3/4 0.16 23/32 5/8 1 1/4 0.31 11/32 11/32 1 1/4 x 1 0.31 15/8 115/32 1 1/2 0.46 17/32 17/32 1 1/2 x 1 1/4 0.35 15/32 13/32 2 0.84 11/2 11/2 2 x 1 1/2 0.58 17/16 11/4 2 1/2 1.41 127/32 127/32 3 2.07 23/32 23/32 3 1/2 2.94 23/8 23/8 4 4.23 225/32 225/32 5 7.74 27/8 27/8 6 10.95 37/16 37/16 8 29.50 423/32 423/32 707 90° Elbow – Close Rough C x C – Cast APPROX. DIM. C DIM. D NOM. SIZE NET WT./LBS. INCHES INCHES 1 1/4 x 1 0.42 15/8 115/32 1 1/4 x 3/4 0.34 9/16 13/16 1 1/4 x 1/2 0.28 15/32 27/32 1 1/2 x 1 0.54 11/16 1 1 1/2 x 3/4 0.42 19/32 31/32 1 1/2 x 1/2 0.40 5/8 29/32 2 x 1 1/4 0.86 7/8 11/4 2 x 1 0.78 3/4 11/4 2 x 3/4 0.69 5/8 11/4 2 1/2 x 2 2.16 13/16 19/32 3 x 2 1/2 2.26 111/16 11/2 3 x 2 2.68 13/8 19/16 4 x 3 5.18 129/32 215/32 607-I 90° Elbow – Intermediate Radius C x C – Wrot APPROX. DIM. C DIM. D NOM. SIZE NET WT./LBS. INCHES INCHES 1/2 0.06 19/32 19/32 5/8 0.09 7/8 7/8 3/4 0.14 13/16 3/16 1 0.24 11/16 11/16 607-LT 90° Elbow – Long Radius C x C – Wrot APPROX. DIM. C DIM. D NOM. SIZE NET WT./LBS. INCHES INCHES 3/16 O.D. 0.01 13/32 13/32 1/8 0.01 13/32 13/32 5/16 O.D. 0.02 9/16 9/16 1/4 0.02 17/32 17/32 1/4 x 1/8 0.01 19/32 1/2 3/8 0.04 23/32 23/32 1/2 0.08 7/8 7/8 1/2 x 3/8 0.06 13/16 13/16 1/2 x 1/4 0.03 25/32 21/32 5/8 0.10 13/32 13/32 5/8 x 1/2 0.09 11/16 11/16 3/4 0.16 11/8 11/8 3/4 x 5/8 0.13 11/4 13/32 3/4 x 1/2 0.10 11/8 11/16 7/8 0.28 119/32 119/32 1 0.28 17/16 17/16 1 x 3/4 0.20 11/4 11/8 1 x 5/8 0.15 113/32 13/32 1 1/4 0.42 17/8 17/8 1 1/4 x 1 0.33 125/32 11/2 1 1/2 0.66 21/4 21/4 2 1.23 215/16 215/16 2 1/2 1.96 311/16 311/16 3 2.93 41/32 41/32 4 5.95 51/4 51/4 Revision 2/7/07 A H E A D O F T H E F L O W ® www.nibco.com NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 15 707-6 90° Union Elbow C x C – Cast APPROX. DIM. A DIM. C NOM. SIZE NET WT./LBS. INCHES INCHES 3/8 0.17 31/32 5/16 1/2 0.24 1 7/16 3/4 0.39 117/32 9/16 1 0.64 121/32 23/32 1 1/4 1.07 119/32 23/32 708 90° Flanged Sink Elbow C x F – Cast NOM. APPROX. DIM. A DIM. C DIM. F SIZE NET WT./LBS. INCHES INCHES INCHES 1/2 0.20 7/8 9/16 13/4 764 90° Double Elbow C x C x C – Cast APPROX. DIM. C DIM. D NOM. SIZE NET WT./LBS. INCHES INCHES 1 x 3/4 x 3/4 0.33 3/4 21/32 ELBOWS continued Consult price sheet for Made to Order items and for minimum order quantities. FITTING REDUCERS APPROX. DIM. B NOM. SIZE NET WT./LBS. INCHES 4 x 3 1/2 2.09 25/8 4 x 3 2.00 31/32 4 x 2 1/2 1.56 31/32 4 x 2 1.76 313/32 5 x 4 3.30 39/16 5 x 3 2.97 41/16 5 x 2 1/2 3.30 411/32 5 x 2 2.88 411/16 6 x 5 5.56 43/16 6 x 4 5.09 49/16 6 x 3 4.67 51/16 6 x 2 1/2 4.47 511/32 6 x 2 4.51 519/32 8 x 6 12.33 515/32 8 x 5 10.35 515/16 8 x 4 11.10 67/16 8 x 3 10.63 615/16 8 x 2 1/2 11.41 73/16 8 x 2 10.86 77/16 741 Companion Flange C – Cast NOM. APPROX. DIM. B DIM. F DIM. G DIM. W SIZE NET WT./LBS. INCHES INCHES INCHES INCHES 1/2 0.55 1/8 31/2 3/16 23/8 3/4 0.71 1/8 37/8 3/16 23/4 1 1.26 1/8 41/4 1/4 31/8 1 1/4 1.42 1/8 45/8 1/4 31/2 1 1/2 1.82 1/8 5 5/16 37/8 2 2.76 1/8 6 3/8 43/4 2 1/2 4.29 1/8 7 3/8 51/2 3 5.26 1/8 71/2 7/16 6 4 7.60 1/8 9 7/16 71/2 5 9.04 1/8 10 7/16 81/2 6 12.68 1/8 11 1/2 91/2 NOTE: Dim. B = Tube Stop to Flange Face 600-2 Fitting Reducer Ftg x C – Wrot APPROX. DIM. B NOM. SIZE NET WT./LBS. INCHES 1/4 x 1/8 0.01 15/32 3/8 x 1/4 0.01 19/32 3/8 x 1/8 0.01 25/32 1/2 x 3/8 0.03 11/16 1/2 x 1/4 0.02 25/32 5/8 x 1/2 0.04 7/8 5/8 x 3/8 0.04 31/32 5/8 x 1/4 0.03 11/32 3/4 x 5/8 0.06 31/32 3/4 x 1/2 0.06 11/8 3/4 x 3/8 0.05 11/8 3/4 x 1/4 0.05 13/32 1 x 3/4 0.10 17/32 1 x 5/8 0.09 13/8 1 x 1/2 0.09 11/4 1 x 3/8 0.08 19/32 1 1/4 x 1 0.15 15/16 1 1/4 x 3/4 0.16 11/2 1 1/4 x 1/2 0.13 13/8 1 1/2 x 1 1/4 0.23 113/32 1 1/2 x 1 0.21 15/8 1 1/2 x 3/4 0.20 17/8 1 1/2 x 1/2 0.16 119/32 2 x 1 1/2 0.40 131/32 2 x 1 1/4 0.34 23/32 2 x 1 0.35 127/32 2 x 3/4 0.35 127/32 2 x 1/2 0.34 131/32 2 1/2 x 2 0.65 131/32 2 1/2 x 1 1/2 0.65 23/8 2 1/2 x 1 1/4 0.60 27/32 2 1/2 x 1 0.78 29/32 3 x 2 1/2 1.03 21/4 3 x 2 0.99 29/16 3 x 1 1/2 0.81 219/32 3 x 1 1/4 1.29 31/4 3 1/2 x 3 1.48 211/32 Continues… FLANGES – CLASS 125 Revision 2/8/07 A H E A D O F T H E F L O W ® www.nibco.com NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 18 APPROX. DIMENSIONS NET WT. INCHES NOM. SIZE LBS. C F G 1 x 1/2 x 1 0.29 11/16 1 21/32 1 x 1/2 x 3/4 0.27 9/16 13/16 3/4 1 x 1/2 x 1/2 0.22 15/32 25/32 23/32 1 1/4 0.43 13/16 3/16 13/16 1 1/4 x 1 1/4 x 2 1.13 130/32 130/32 13/32 1 1/4 x 1 1/4 x 1 1/2 0.60 13/16 13/16 29/32 1 1/4 x 1 1/4 x 1 0.45 25/32 25/32 29/32 1 1/4 x 1 1/4 x 3/4 0.37 21/32 21/32 3/4 1 1/4 x 1 1/4 x 1/2 0.30 1/2 1/2 25/32 1 1/4 x 1 1/4 x 3/8 0.34 23/32 23/32 29/32 1 1/4 x 1 x 1 1/4 0.43 13/16 11/32 13/16 1 1/4 x 1 x 1 0.47 25/32 7/8 29/32 1 1/4 x 1 x 3/4 0.35 21/32 25/32 7/8 1 1/4 x 1 x 1/2 0.30 1/2 5/8 29/32 1 1/4 x 3/4 x 1 1/4 0.42 13/16 11/8 13/16 1 1/4 x 3/4 x 1 0.45 25/32 11/32 29/32 1 1/4 x 3/4 x 3/4 0.37 21/32 15/16 7/8 1 1/4 x 3/4 x 1/2 0.30 1/2 3/4 29/32 1 1/4 x 1/2 x 1 1/4 0.41 13/16 17/32 13/16 1 1/2 0.61 31/32 31/32 29/32 1 1/2 x 1 1/2 x 2 1.11 125/32 125/32 13/32 1 1/2 x 1 1/2 x 1 1/4 0.62 29/32 29/32 11/16 1 1/2 x 1 1/2 x 1 0.55 11/16 11/16 7/8 1 1/2 x 1 1/2 x 3/4 0.45 11/16 11/16 11/32 1 1/2 x 1 1/2 x 1/2 0.40 1/2 1/2 11/32 1 1/2 x 1 1/4 x 1 1/2 0.62 11/32 13/16 29/32 1 1/2 x 1 1/4 x 1 1/4 0.62 31/32 13/32 31/32 1 1/2 x 1 1/4 x 1 0.51 25/32 1 11/32 1 1/2 x 1 1/4 x 3/4 0.49 11/16 13/16 11/32 1 1/2 x 1 1/4 x 1/2 0.41 1/2 25/32 11/32 1 1/2 x 1 x 1 1/2 0.59 11/32 111/32 29/32 1 1/2 x 1 x 1 1/4 0.63 29/32 11/8 11/16 1 1/2 x 1 x 1 0.54 25/32 11/16 11/32 1 1/2 x 1 x 3/4 0.44 11/16 31/32 15/16 1 1/2 x 1 x 1/2 0.39 1/2 25/32 11/32 1 1/2 x 3/4 x 1 1/2 0.62 11/32 17/16 11/16 1 1/2 x 3/4 x 1 1/4 0.58 29/32 111/32 11/16 1 1/2 x 3/4 x 1 0.54 25/32 11/4 11/32 1 1/2 x 3/4 x 3/4 0.47 11/16 13/32 29/32 1 1/2 x 3/4 x 1/2 0.39 1/2 29/32 31/32 1 1/2 x 1/2 x 1 1/2 0.62 11/32 113/32 31/32 Continues… APPROX. DIMENSIONS NET WT. INCHES NOM. SIZE LBS. C F G 2 1.30 19/32 19/32 11/32 2 x 2 x 2 1/2 2.34 2 2 121/32 2 x 2 x 1 1/2 1.17 11/4 11/4 123/32 2 x 2 x 1 1/4 1.12 9/32 9/32 17/8 2 x 2 x 1 0.90 27/32 27/32 11/4 2 x 2 x 3/4 0.88 19/32 19/32 11/4 2 x 2 x 1/2 1.17 11/4 11/4 21/4 2 x 1 1/2 x 2 1.16 19/32 17/8 111/32 2 x 1 1/2 x 1 1/2 1.15 11/4 13/4 123/32 2 x 1 1/2 x 1 1/4 1.15 7/32 13/4 111/32 2 x 1 1/2 x 3/4 0.83 21/32 15/16 17/32 2 x 1 1/2 x 1/2 1.12 11/4 125/32 21/4 2 x 1 1/4 x 2 1.58 19/32 115/32 19/32 2 x 1 1/4 x 1 1/2 1.16 11/4 131/32 123/32 2 x 1 1/4 x 1 1/4 1.19 15/16 111/32 111/32 2 x 1 1/4 x 1 0.90 27/32 19/32 111/32 2 x 1 1/4 x 3/4 0.85 21/32 1 18/27 2 x 1 x 2 1.11 11/8 125/32 11/4 2 x 1 x 1 0.89 27/32 19/32 111/32 2 x 3/4 x 2 1.15 19/32 23/16 11/4 2 x 1/2 x 2 1.15 19/32 23/8 11/4 2 1/2 2.40 15/8 15/8 15/8 2 1/2 x 2 1/2 x 2 1.97 15/16 15/16 121/32 2 1/2 x 2 1/2 x 1 1/2 1.53 13/32 13/32 121/32 2 1/2 x 2 1/2 x 1 1/4 1.72 13/32 13/32 127/32 2 1/2 x 2 1/2 x 1 1.34 25/32 25/32 111/16 2 1/2 x 2 1/2 x 3/4 1.34 25/32 25/32 113/16 2 1/2 x 2 1/2 x 1/2 1.34 25/32 25/32 21/8 2 1/2 x 2 x 2 1/2 1.99 121/32 23/32 121/32 2 1/2 x 2 x 2 1.95 111/32 15/8 123/32 2 1/2 x 2 x 1 1/2 1.57 13/32 213/32 121/32 2 1/2 x 2 x 1 1/4 1.57 13/32 119/32 127/32 2 1/2 x 2 x 1 1.40 25/32 19/32 13/4 2 1/2 x 2 x 3/4 1.35 25/32 19/32 127/32 2 1/2 x 1 1/2 x 1 1/2 1.76 13/32 113/32 13/8 2 1/2 x 1 1/4 x 2 1/2 2.40 121/32 27/16 121/32 2 1/2 x 1 x 2 1/2 2.04 121/32 223/32 121/32 2 1/2 x 3/4 x 2 1/2 2.00 121/32 211/16 121/32 2 1/2 x 1/2 x 2 1/2 2.46 11/2 27/32 11/2 Continues… APPROX. DIMENSIONS NET WT. INCHES NOM. SIZE LBS. C F G 3 3.15 17/8 17/8 21/32 3 x 3 x 2 1/2 3.55 129/32 129/32 23/8 3 x 3 x 2 3.19 115/32 115/32 131/32 3 x 3 x 1 1/2 3.08 115/32 115/32 29/32 3 x 3 x 1 1/4 3.10 115/32 115/32 27/16 3 x 3 x 1 2.12 27/32 27/32 131/32 3 x 3 x 3/4 2.39 27/32 27/32 23/16 3 x 3 x 1/2 1.82 27/32 27/32 23/8 3 x 2 1/2 x 3 3.08 17/8 23/8 131/32 3 x 2 1/2 x 2 1/2 3.12 129/32 211/32 25/32 3 x 2 1/2 x 2 2.28 115/32 127/32 131/32 3 x 2 x 3 3.62 129/32 217/32 115/16 3 x 2 x 2 1/2 3.56 129/32 29/16 25/16 3 x 2 x 2 3.22 115/32 131/32 131/32 3 x 1 1/2 x 3 3.13 129/32 225/32 23/32 3 x 1 1/4 x 3 3.63 129/32 225/32 115/16 3 x 1 x 3 3.20 131/32 219/32 23/16 3 x 3/4 x 3 3.55 131/32 229/32 23/16 3 1/2 5.20 217/32 217/32 217/32 4 8.12 213/32 213/32 217/32 4 x 4 x 3 6.70 21/32 21/32 221/32 4 x 4 x 2 1/2 6.65 21/32 21/32 35/32 4 x 4 x 2 5.82 115/32 115/32 27/16 4 x 4 x 1 1/2 3.94 111/32 111/32 217/32 4 x 4 x 1 1/4 4.04 111/32 111/32 229/32 4 x 4 x 1 3.72 1 1 29/16 4 x 4 x 3/4 3.70 1 1 211/16 4 x 3 x 4 7.05 225/32 37/32 217/32 4 x 3 x 3 5.03 21/32 215/32 215/32 4 x 3 x 2 1/2 5.04 21/32 215/32 229/32 4 x 3 x 2 5.87 115/32 131/32 27/16 4 x 2 1/2 x 4 7.19 225/32 315/32 227/32 4 x 2 x 4 7.08 225/32 319/32 227/32 Continued on next page. NOTE: Tee sizes are read Run x Run x Outlet. 611 Tee C x C x C – Wrot continued TEES continued Consult price sheet for Made to Order items and for minimum order quantities. Revision 2/8/07 A H E A D O F T H E F L O W ® www.nibco.com NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 49 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. Copper Water Tube continued DIMENSIONAL DATA – COPPER WATER TUBE – TYPE “M” TYPE “M” Hard Drawn Only: 20-ft. (6.1m) Straight Lengths Usage: For general purpose plumbing, heating and drainage installations. Tolerances Hard Drawn (Hard Drawn Only) Outside Tubing OD Nominal Wall Weight Bursting Safe Working Nominal Diameter Thickness Per Foot PressureA PressureB Water Tube Min. Max. Size (In Inches) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Lb (kg) psi (bars) psi (bars) 1/4 0.375 (9.53) 0.373 (9.47) 0.376 (9.55) N/A N/A N/A N/A N/A N/A N/A N/A 3/8 0.500 (12.70) 0.497 (12.62) 0.501 (12.73) 0.025 (0.64) 0.145 (0.07) N/A N/A 855 (59) 1/2 0.625 (15.88) 0.622 (15.80) 0.626 (15.90) 0.028 (0.71) 0.204 (0.09) 6135 (423) 741 (51) 5/8 0.750 (19.05) 0.747 (18.97) 0.751 (19.08) N/A N/A N/A N/A N/A N/A N/A N/A 3/4 0.875 (22.23) 0.872 (22.15) 0.876 (22.25) 0.032 (0.81) 0.328 (0.15) 4717 (325) 611 (42) 1 1.125 (28.58) 1.122 (28.50) 1.127 (28.63) 0.035 (0.89) 0.465 (0.21) 3865 (266) 506 (35) 1 1/4 1.375 (34.93) 1.372 (34.85) 1.377 (34.98) 0.042 (1.07) 0.682 (0.31) 3875 (267) 507 (35) 1 1/2 1.625 (41.28) 1.621 (41.17) 1.627 (41.33) 0.049 (1.24) 0.940 (0.43) 3550 (245) 497 (34) 2 2.125 (53.98) 2.121 (53.87) 2.127 (54.03) 0.058 (1.47) 1.460 (0.66) 2935 (202) 448 (31) 2 1/2 2.625 (66.68) 2.621 (66.57) 2.627 (66.73) 0.065 (1.65) 2.030 (0.92) 2800 (193) 411 (28) 3 3.125 (79.38) 3.121 (79.27) 3.127 (79.43) 0.072 (1.83) 2.680 (1.22) 2665 (184) 380 (26) 3 1/2 3.625 (92.08) 3.621 (91.97) 3.627 (92.13) 0.083 (2.11) 3.580 (1.62) N/A N/A 378 (26) 4 4.125 (104.78) 4.121 (104.67) 4.127 (104.83) 0.095 (2.41) 4.660 (2.11) 2215 (153) 377 (26) 5 5.125 (130.18) 5.121 (130.07) 5.127 (130.23) 0.109 (2.77) 6.660 (3.02) 2490 (172) 349 (24) 6 6.125 (155.58) 6.121 (155.47) 6.127 (155.63) 0.122 (3.10) 8.920 (4.05) 2000 (138) 328 (23) 8 8.125 (206.38) 8.119 (206.22) 8.127 (206.43) 0.170 (4.32) 16.500 (7.48) 2285 (158) 344 (24) 10 10.125 (257.18) 10.119 (257.02) 10.127 (257.23) 0.212 (5.38) 25.600 (11.61) N/A N/A 344 (24) 12 12.125 (307.98) 12.119 (307.82) 12.127 (308.03) 0.254 (6.45) 36.700 (16.65) N/A N/A 345 (24) Note: Information and data contained in these charts, as taken from ASTM Specifications B 88. Rated internal pressure for copper water tube based on the strength of the tube alone and applicable to systems using suitable mechanical joints. A Based on actual laboratory test data provided by Copper Development Association, Inc. B Based upon 150°F (65.6°C) with an allowable stress of 9500 psi (668 kPa). Revision 5/12/02 A H E A D O F T H E F L O W ® www.nibco.com NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 62 1" TYPE “M” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D. = 1.1265 inches (28.613 mm) Nominal O.D. = 1.1250 inches (28.575 mm) Minimum O.D. = 1.1235 inches (28.537 mm) Nominal I.D. = 1.0558 inches (26.797 mm) Nominal Wall Thickness = 0.0350 inches (0.889 mm) Flow Area = 0.8742 sq. inches (563.98 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q Pressure Loss Head Loss Velocity FLOW, Q Pressure Loss Head Loss Velocity (GPM) (psi/100 ft) (ft/100 ft) (ft./sec.) (cu. cm/sec.) (kPa/100 m) (m/100 m) (m/sec.) 2.50 0.18 0.41 0.92 158 0.04 0.41 0.28 5.00 0.64 1.49 1.84 315 0.14 1.49 0.56 7.50 1.36 3.15 2.75 473 0.31 3.15 0.84 10.00 2.31 5.37 3.67 631 0.52 5.37 1.12 12.50 3.49 8.11 4.59 789 0.79 8.11 1.40 15.00 4.90 11.36 5.51 946 1.11 11.36 1.68 17.50 6.52 15.11 6.42 1104 1.47 15.11 1.96 20.00 8.34 19.35 7.34 1262 1.89 19.35 2.24 22.50 10.38 24.06 8.26 1419 2.35 24.06 2.52 25.00 12.61 29.24 9.18 1577 2.85 29.24 2.80 27.50 15.05 34.88 10.09 1735 3.40 34.88 3.08 30.00 17.68 40.97 11.01 1893 4.00 40.97 3.36 32.50 20.51 47.51 11.93 2050 4.64 47.51 3.64 35.00 23.52 54.49 12.85 2208 5.32 54.49 3.92 37.50 26.73 61.91 13.76 2366 6.05 61.91 4.19 40.00 30.12 69.76 14.68 2523 6.81 69.76 4.47 42.50 33.70 78.04 15.60 2681 7.62 78.04 4.75 45.00 37.47 86.74 16.52 2839 8.47 86.74 5.03 47.50 41.41 95.87 17.43 2997 9.37 95.87 5.31 50.00 45.54 105.41 18.35 3154 10.30 105.41 5.59 52.50 49.84 115.37 19.27 3312 11.28 115.37 5.87 55.00 54.33 125.74 20.19 3470 12.29 125.74 6.15 1 1/4" TYPE “K” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D. = 1.3765 inches (34.963 mm) Nominal O.D. = 1.3750 inches (34.925 mm) Minimum O.D. = 1.3735 inches (34.887 mm) Nominal I.D. = 1.2450 inches (31.623 mm) Nominal Wall Thickness = 0.0650 inches (1.651 mm) Flow Area = 1.2174 sq. inches (785.41 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q Pressure Loss Head Loss Velocity FLOW, Q Pressure Loss Head Loss Velocity (GPM) (psi/100 ft) (ft/100 ft) (ft./sec.) (cu. cm/sec.) (kPa/100 m) (m/100 m) (m/sec.) 5.00 0.29 0.67 1.32 315 0.06 0.67 0.40 10.00 1.03 2.40 2.64 631 0.23 2.40 0.80 15.00 2.19 5.08 3.95 946 0.49 5.08 1.20 20.00 3.73 8.65 5.27 1262 0.84 8.65 1.61 25.00 5.64 13.06 6.59 1577 1.27 13.06 2.01 30.00 7.90 18.30 7.91 1893 1.79 18.30 2.41 35.00 10.51 24.34 9.22 2208 2.38 24.34 2.81 40.00 13.46 31.17 10.54 2523 3.04 31.17 3.21 45.00 16.74 38.75 11.86 2839 3.79 38.75 3.61 50.00 20.35 47.09 13.18 3154 4.60 47.09 4.02 55.00 24.27 56.18 14.49 3470 5.49 56.18 4.42 60.00 28.52 65.99 15.81 3785 6.45 65.99 4.82 65.00 33.07 76.52 17.13 4101 7.48 76.52 5.22 70.00 37.94 87.76 18.45 4416 8.58 87.76 5.62 75.00 43.11 99.71 19.77 4732 9.75 99.71 6.02 80.00 48.58 112.35 21.08 5047 10.99 112.35 6.43 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. Revision 5/12/02 A H E A D O F T H E F L O W ® www.nibco.com NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 63 1 1/4" TYPE “L” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D. = 1.3765 inches (34.963 mm) Nominal O.D. = 1.375 inches (34.925 mm) Minimum O.D. = 1.3735 inches (34.887 mm) Nominal I.D. = 1.265 inches (32.131 mm) Nominal Wall Thickness = 0.0550 inches (1.397 mm) Flow Area = 1.2568 sq. inches (810.85 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q Pressure Loss Head Loss Velocity FLOW, Q Pressure Loss Head Loss Velocity (GPM) (psi/100 ft) (ft/100 ft) (ft./sec.) (cu. cm/sec.) (kPa/100 m) (m/100 m) (m/sec.) 5.00 0.26 0.62 1.28 315 0.06 0.62 0.39 10.00 0.96 2.22 2.55 631 0.22 2.22 0.78 15.00 2.02 4.70 3.83 946 0.46 4.70 1.17 20.00 3.45 8.00 5.11 1262 0.78 8.00 1.56 25.00 5.22 12.09 6.38 1577 1.18 12.09 1.95 30.00 7.31 16.94 7.66 1893 1.65 16.94 2.33 35.00 9.73 22.53 8.93 2208 2.20 22.53 2.72 40.00 12.45 28.84 10.21 2523 2.82 28.84 3.11 45.00 15.49 35.86 11.49 2839 3.50 35.86 3.50 50.00 18.83 43.58 12.76 3154 4.26 43.58 3.89 55.00 22.46 51.98 14.04 3470 5.08 51.98 4.28 60.00 26.39 61.06 15.32 3785 5.97 61.06 4.67 65.00 30.61 70.81 16.59 4101 6.92 70.81 5.06 70.00 35.11 81.21 17.87 4416 7.94 81.21 5.45 75.00 39.89 92.27 19.15 4732 9.02 92.27 5.84 80.00 44.96 103.97 20.42 5047 10.17 103.97 6.22 1 1/4" TYPE “M” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D. = 1.3765 inches (34.963 mm) Nominal O.D. = 1.3750 inches (34.925 mm) Minimum O.D. = 1.3735 inches (34.887 mm) Nominal I.D. = 1.2910 inches (32.7914 mm) Nominal Wall Thickness = 0.0420 inches (1.067 mm) Flow Area = 1.3090 sq. inches (844.52 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q Pressure Loss Head Loss Velocity FLOW, Q Pressure Loss Head Loss Velocity (GPM) (psi/100 ft) (ft/100 ft) (ft./sec.) (cu. cm/sec.) (kPa/100 m) (m/100 m) (m/sec.) 5.00 0.24 0.56 1.23 315 0.05 0.56 0.37 10.00 0.87 2.01 2.45 631 0.20 2.01 0.75 15.00 1.83 4.26 3.68 946 0.41 4.26 1.12 20.00 3.12 7.25 4.90 1262 0.71 7.25 1.49 25.00 4.72 10.95 6.13 1577 1.07 10.95 1.87 30.00 6.62 15.34 7.35 1893 1.50 15.34 2.24 35.00 8.81 20.40 8.58 2208 1.99 20.40 2.61 40.00 11.28 26.12 9.80 2523 2.55 26.12 2.99 45.00 14.03 32.48 11.03 2839 3.17 32.48 3.36 50.00 17.05 39.47 12.25 3154 3.86 39.47 3.74 55.00 20.34 47.08 13.48 3470 4.60 47.08 4.11 60.00 23.90 55.31 14.71 3785 5.41 55.31 4.48 65.00 27.72 64.14 15.93 4101 6.27 64.14 4.86 70.00 31.80 73.56 17.16 4416 7.19 73.56 5.23 75.00 36.13 83.57 18.38 4732 8.17 83.57 5.60 80.00 40.72 94.17 19.61 5047 9.21 94.17 5.98 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. Revision 5/12/02 A H E A D O F T H E F L O W ® www.nibco.com NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 81 Copper Water Tube continued COPPER TUBE – TYPES, STANDARDS, APPLICATIONS, TEMPERS AND LENGTHS Commercially Available Lengths Tube Type Color Code Standard Application Nominal or Standard Sizes Drawn Annealed Type K Green ASTM B 88 Domestic Water Service Distribution Straight Lengths: 1/4-inch to 8-inch 20 ft. (6.1m) 20 ft. (6.1m) Fire Protection 10-inch 18 ft. (5.5m) 18 ft. (5.5m) Solar 12-inch 12 ft. (3.7m) 12 ft. (3.7m) Fuel/Fuel Oil Coils: 1/4-inch to 1-inch – 60 ft. (18.3m) HVAC – 100 ft. (30.5m) Snow Melting 11/4-inch & 11/2-inch – 60 ft. (18.3m) 2-inch – 40 ft. (12.2m) – 45 ft. (13.7m) Type L Blue ASTM B 88 Domestic Water Service Distribution Straight Lengths: 1/4-inch to 10-inch 20 ft. (6.1m) 20 ft. (6.1m) Fire Protection 12-inch 18 ft. (5.5m) 18 ft. (5.5m) Solar Fuel/Fuel Oil Natural Gas Coils: 1/4-inch to 1-inch – 60 ft. (18.3m) Liquified Petroleum (LP) Gas – 100 ft. (30.5m) HVAC 11/4-inch & 11/2-inch – 60 ft. (18.3m) Snow Melting 2-inch – 40 ft. (12.2m) – 45 ft. (13.7m) Type M Red ASTM B 88 Domestic Water Service Distribution Straight Lengths: 1/4-inch to 12-inch 20 ft. (6.1m) N/A Fire Protection Solar Fuel/Fuel Oil HVAC Snow Melting DWV Yellow ASTM B 306 Drain Straight Lengths: 11/4-inch to 8-inch 20 ft. (6.1m) N/A Waste Vent HVAC Solar ACR Blue ASTM B 280 Air Conditioning Straight Lengths: 1/4-inch to 41/8-inch 20 ft. (6.1m) 20 ft. (6.1m)1 Refrigeration Natural Gas Coils: 1/8-inch to 15/8-inch – 50 ft. (15.3m)1 Liquified Petroleum (LP) Gas OXY Type K ASTM B 819 Medical Gas Straight Lengths: 1/4-inch to 8-inch 20 ft. (6.1m) N/A MED Green OXY/MED OXY/ACR Type L ACR/MED Blue Type G Yellow ASTM B 837 Natural Gas Straight Lengths: 3/8-inch to 11/8-inch 12 ft. (3.7m) 12 ft. (3.7m)1 Liquified Petroleum (LP) Gas 20 ft. (6.1m) 20 ft. (6.1m)1 Coils: 3/8-inch to 7/8-inch – 60 ft. (18.3m)1 – 100 ft. (30.5m)1 1 Available as special order only. U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. Revision 5/12/02 A H E A D O F T H E F L O W ® www.nibco.com NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 16 Consult price sheet for Made to Order items and for minimum order quantities. FLANGES – CLASS 150 771 Companion Flange C – Cast NOM. APPROX. DIM. B DIM. F DIM. G DIM. W SIZE NET WT./LBS. INCHES INCHES INCHES INCHES 3/4 1.15 1/8 37/8 11/32 23/4 1 1.59 1/8 41/4 3/8 31/8 1 1/4 1.91 1/8 45/8 13/32 31/2 1 1/2 2.59 1/8 5 7/16 37/8 2 4.10 1/8 6 1/2 43/4 2 1/2 6.22 1/8 7 9/16 51/2 3 8.03 1/8 71/2 5/8 6 4 11.85 1/8 9 11/16 71/2 5 15.69 1/8 10 3/4 81/2 6 20.32 1/8 11 13/16 91/2 NOTE: Dim. B = Tube Stop to Flange Face 775 Threaded Companion Flange F – Cast NOM. APPROX. DIM. E DIM. F DIM. W SIZE NET WT./LBS. INCHES INCHES INCHES 2 4.31 1 6 43/4 2 1/2 6.30 11/8 7 51/2 3 7.13 13/16 71/2 6 4 10.20 15/16 9 71/2 PLUGS 616 Fitted Plug Ftg - Wrot APPROX. DIM. A NOM. SIZE NET WT./LBS. INCHES 3/8 0.016 1/16 1/2 0.02 3/32 3/4 0.24 1/8 638 Return Bend C x C – Wrot APPROX. DIM. E DIM. J NOM. SIZE NET WT./LBS. INCHES INCHES 1/8 0.02 21/32 1 1/4 0.04 21/32 11/2 3/8 0.08 11/32 11/2 1/2 0.13 11/2 2 3/4 0.26 119/32 21/2 1 0.44 23/32 3 1 1/4 0.70 23/4 4 1 1/2 1.04 35/32 41/2 2 1.92 329/32 51/2 739 Return Bend – Closed C x C – Cast APPROX. DIM. E DIM. J NOM. SIZE NET WT./LBS. INCHES INCHES 3/4 0.29 15/32 15/16 RETURN BENDS STRAPS TEES 623 Copper Hanger Strap APPROX. SIZE NET WT./LBS. 3/4" Wide x 25 Ft. Roll 1.93 624 Tube Strap APPROX. NOM. SIZE NET WT./LBS. 1/8 0.01 1/4 0.01 3/8 0.01 1/2 0.01 5/8 0.02 3/4 0.02 1 0.02 1 1/4 0.03 1 1/2 0.03 2 0.04 705 Baseboard Tee C x F x C – Cast APPROX. DIMENSIONS NET WT. INCHES NOM. SIZE LBS. C D E 1/2 x 1/8 x 3/4 0.15 7/16 9/16 11/16 1/2 x 1/8 x 1/2 0.11 7/16 7/16 9/16 3/4 x 1/8 x 1 0.29 5/8 3/4 13/16 3/4 x 1/8 x 3/4 0.19 9/16 9/16 11/16 1 x 1/8 x 1 0.32 23/32 23/32 3/4 1 1/4 x 1/8 x 1 1/4 0.51 7/8 7/8 15/16 Revision 2/8/07