Loading...
HomeMy WebLinkAboutF15-0038_Wall St. - Submittal_1433366520.pdf 7026 South Tucson Way Centennial, CO 80112 (303) 792-0022 Fax (303) 792-9049 Fire Sprinkler System Product Data Submittal For Wall Street Building 225 East Meadows Drive Vail, CO 81657 WSFP #CS2662 Prepared By: Nick Pippin Project Manager Western States Fire Protection Co. 7026 S. Tucson Way Centennial, CO 80112 Cell (720) 539-0494 Phone (303) 792-0022 Fax (303) 792-9049 Email: nick.pippin@wsfp.us June 3, 2015 Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Bulletin 034 Rev. DBulletin 034 Rev. D Model G5-80, Model G5-56, Model G5-42, Model G5-28 Quick Response Concealed Automatic Sprinkler UL Quick Response FM Standard Response Concealed Sprinkler With a 3/4” (19mm) Adjustment Features 1. Cover plate attachment (Plain or Perforated) with ¾” (19mm) assembly adjustment. 2. Smooth aesthetic ceiling profile. 3. Factory installed protective cap. 4. Available in Chrome and White as Standard Finish- es. Special Application Finishes are also available. 5. Ordinary and Intermediate temperature rating. For additional Sprinklers refer to Bulletin 154 for Technical Specifi cation and Approvals Approvals & Listings 1. Underwriters Laboratories Inc. and cULus - Quick Response • G5-80, G5-56 - Light Hazard and Ordinary Hazard Occupancies • G5-42 - Light Hazard Occupancies • G5-28 - Light Hazard Occupancies 2. Factory Mutual Research Corp. (FM) - Standard Response (See Page 3) • G5-56 & G5-28 only. • See the most recent FM Global Property Loss Prevention Data Sheets for installation and use guidelines. 3. Loss Prevention Council (LPCB, UK) - Standard Response • G5-56 - Light Hazard and Ordinary Hazard Occupancies 4. VdS Schadenverhütung GmbH - Standard Response 5. EC-Certificate of Conformity 0832-CPD-2062 U.S. Patent number 6,554,077. Application The Reliable Model G5-80, G5-56, G5-42 and G5-28 are the most versatile quick response concealed sprinklers avail- able. It provides the best form of fire protection while offering an attractive appearance and 3/4” (19mm) of cover adjust- ment for ease of installation. The small diameter cover plate assembly is easily attached and blends into the ceiling, con- cealing the most dependable fire protection available, an au- tomatic sprinkler system. The Model G5-80, G5-56, G5-42 and G5-28 are designed for use where aesthetic appearance is important. Offices, hos- pitals, motels and restaurants are but a few of the applications where it can be used. The Model G5-80, G5-56, G5-42 and G5-28 are UL Listed Quick Response Concealed sprinklers intended for use in accordance with NFPA 13. FM Approves the G5-56 and the G5-28 sprinkler as a standard response concealed sprinkler intended for use in accordance with FM Loss Prevention Data Sheet 2.0. Product Description The Reliable Model G5-80, G5-56, G5-42 and G5-28 uses a proven quick response fusible element in a standard style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate assembly. The threaded engagement provides ¾” (19mm) of cover adjustment. The flat cover plate is attached to the skirt using either 135°F (57°C) or 165°F (74°C) ordinary tempera- ture classification solder. When the ceiling temperature rises, the solder holding the flat cover plate melts, the flat cover plate released thus expos- ing the sprinkler inside to the rising ambient temperature. The subsequent fusing of the element opens the waterway and causes the deflector to distribute the water. Any secure engagement between the cover plate and cup will assure that the drop-down deflector is properly located below the ceiling. Plain Cover Plate Perforated Cover Plate Installation Do not install the G5-80, G5-56, G5-42 and G5-28 in ceilings which have positive pressure in the space above. • Cut a 25/8” inch (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model FC Wrench. The wrench has a socket drive which is inserted into the body of the sprinkler. When installing a sprinkler the wrench is first positioned into the sprinkler/cup assembly until the wrench socket engages the body of the sprinkler. The sprinkler is then tightened into the pipe fitting. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER/ CUP ASSEMBLY. Install the cover plate by hand turning the cover in the clockwise direction until it is tight against the ceil- ing. A protective cap is provided to protect the drop-down sprinkler deflector from damage which could occur during construction before the cover plate is installed. The cap is factory installed inside the sprinkler cup. Remove cap to install sprinkler, then re- install cap until the cover plate is installed. Maintenance The Model G5-80, G5-56, G5-42 and G5-28 should be in- spected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, am- monia or any other cleaning fluids. Remove any sprinkler that has been painted (other than factory applied) or damaged in any way. Concealed sprinklers cover plates can not be painted in the field, after installation or have any other coating applied other than the factory finish. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or oper- ated sprinklers. Prior to installation, sprinklers should be main- tained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. UL Listing Category Sprinklers, Automatic and Open Quick Response Sprinkler UL Guide Number VNIV Maximum Working Pressure 175 psi (12 bar) 100% Factory tested Hydrostatically to 500 psi (34.5 bar) Temperature Rating Classifi cation Sprinkler Cover Plate Max. Ambient Temp. Ordinary 165°F/74°C 135°F/57°C 100°F/38°C Intermediate 212°F/100°C 165°F/74°C 150°F/66°C Model FC Sprinkler Wrench Ordering Information 1. Sprinkler Model 2. Nominal Orifice 3. Flat Cover Plate Plain or Perforated 4. Flat Cover Plate Assembly Finish 5. Inlet Type Cover Plate Finishes(1) Standard Finishes Chrome White Paint Special Application Finishes(2) Bright Brass Finished Bronze Black Plating Black Paint Off White Satin Chrome (1) Other finishes and colors are available on special order. Consult factory for details. Coverplate custom paint is semi-gloss, unless specified otherwise. (2) For the perforated style cover- plate, consult factory for avail- ability on these and other cus-tom finishes. 2. Technical Data Sprinkler Model Sprinkler Inlet Total Adjustment Nominal Orifi ce Nominal K Factor Thread Approvals Sprinkler Identifi cation (SIN)US Metric G5-80 Non Adjustable ¾” (19mm) 17/32” (15mm) 8.0 115 ¾” NPT (R¾) 1 RA3412 G5-56 Non Adjustable ¾” (19mm) ½” (15mm) 5.6 80 ½” NPT (R½) 1,2,3,4,5 RA3415 G5-42 Non Adjustable ¾” (19mm) 7/16” (10mm) 4.2 60 ½” NPT (R½) 1 RA3413 G5-28 Non Adjustable ¾” (19mm) 3/8” (10mm) 2.8 40 ½” NPT (R½) 1,2 RA3411 For VdS Approval, temperature rating sprinkler 165°F/74°c and cover plate 135°F/57°C only! Notice FOR USE AS A REPLACEMENT OF MODEL G4A SPRINKLERS NOTE: 1. Testing has shown that use of a “nipple extension” will not affect the listing of the sprinkler. 2. For RETROFIT installations, per NFPA 13 (2010) section 8.15.19.4, “which allows the use of nipples as the same pipe thread size as the existing outlet when revamping existing systems”. 3. Do not exceed 8-18 ft-lbs of torque during installation. 3. Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices(800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 11/14 P/N 9999970421 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Reliable...For Complete Protection Hydraulic Summary Report Description: RETAIL UNIT 104 Job Number: CS2662 - RETAIL Node Flow(gpm) Total Hose Streams 250.00 Safety MarginRequiredAvailable Node Hose Flow Static Residual Flow Total Demand (gpm)(psi)(psi)(gpm)(psi)(gpm)(psi)(psi)@@Name 1 110.975 94.827 16.149724.00250.00 77.000150.000 516.09Water Supply Design EngineerJob Number Total Water Required (Including Hose Allowance) 516.09 Maximum Pressure Unbalance In Loops 0.000 Additional Hose Supplies 250.00 Hose Allowance At Source Supplies 307.49gal Ordinary Group II 0.200gpm/ft² 130.00ft² 834.00ft² (Actual 834.49ft²) 9 Occupancy Area of Application Coverage Per SprinklerNumber Of Sprinklers Calculated Density RETAIL Job Suffix Volume capacity of Dry PipesVolume capacity of Wet Pipes 5.93 between nodes 1 and 2 Maximum Velocity Under Ground 23.95 between nodes 12 and 15 Maximum Velocity Above Ground 5.6 K-Factor 26.00 at 21.556 Most Demanding Sprinkler Data System Wall StreetVail CO 81658 Job Site/Building Vail Fire Dept.225 Wall Street AHJ 032Wall Street Remodel Job State Certification/License NumberJob Name: Nick PippinCS2662 Contractor Contractor Number032 Name of Contractor: Western States Fire Protection Address 1 274 Center Drive Address 2 Glenwood Springs, CO. 81601 Contact Name Contact TitlePM ExtensionPhone FAX E-mail nick.pippin@wsfp.us Web-Site Nick Pippin Address 3 Address 1 Address 2 Drawing Name CS2662 - Wall Street.cad System Flow Demand 266.09 Remote Area(s) Address 3 5/26/2015© M.E.P.CAD, Inc.Page 1AutoSPRINK® VR11 v11.0.30.0 8:27:56AM Hydraulic Graph Report Description: RETAIL UNIT 104 Job Number: CS2662 - RETAIL System Demand (Including Hose Allowance at Source) System Demand 77.000 @ 724.00 Residual: Pressure 150.000 Static: Pressure Water Supply at Node 1 Hydraulic Graph Water Supply at Node 1 94.827 @ 266.09 94.827 @ 516.09 Available Pressure at Time of Test 110.975 @ 516.09 © M.E.P.CAD, Inc.5/26/2015 Page 2AutoSPRINK® VR11 v11.0.30.0 8:28:01AM Hydraulic Graph Report Description: RETAIL UNIT 104 Job Number: CS2662 - RETAIL System Demand (Including Hose Allowance at Source) System Demand N/A Residual: Pressure N/A Static: Pressure BOR Hydraulic Graph BOR 0.000 @ 0.00 0.000 @ N/A Available Pressure at Time of Test N/A © M.E.P.CAD, Inc.5/26/2015 Page 3AutoSPRINK® VR11 v11.0.30.0 8:28:01AM Hydraulic Graph Report Description: RETAIL UNIT 104 Job Number: CS2662 - RETAIL System Demand (Including Hose Allowance at Source) System Demand N/A Residual: Pressure N/A Static: Pressure BOR Hydraulic Graph BOR 0.000 @ 0.00 0.000 @ N/A Available Pressure at Time of Test N/A © M.E.P.CAD, Inc.5/26/2015 Page 4AutoSPRINK® VR11 v11.0.30.0 8:28:01AM Device (gpm) Actual Flow Minimum Flow (gpm)(K) K-Factor (psi) Pressure (gpmpft2) Density Summary Of Outflowing Devices Report Description: RETAIL UNIT 104 Job Number: CS2662 - RETAIL Coverage (Foot) Sprinkler 101 30.89 26.00 5.6 30.432 0.238gpm/ft²130.00ft² Sprinkler 102 28.51 26.00 5.6 25.912 0.219gpm/ft²130.00ft² Sprinkler 103 32.59 26.00 5.6 33.859 0.251gpm/ft²130.00ft² Sprinkler 104 26.00 26.00 5.6 21.556 0.200gpm/ft²130.00ft² Sprinkler 105 30.30 26.00 5.6 29.267 0.233gpm/ft²130.00ft² Sprinkler 106 31.46 26.00 5.6 31.551 0.242gpm/ft²130.00ft² Sprinkler 107 26.20 26.00 5.6 21.890 0.202gpm/ft²130.00ft² Sprinkler 108 29.51 26.00 5.6 27.766 0.227gpm/ft²130.00ft² Sprinkler 109 30.64 26.00 5.6 29.940 0.236gpm/ft²130.00ft² Most Demanding Sprinkler Data © M.E.P.CAD, Inc.5/26/2015 Page 5AutoSPRINK® VR11 v11.0.30.0 8:28:03AM Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: CS2662 - RETAIL Report Description: RETAIL UNIT 104 • • • • • Route 1 • • • • • Pf Pe Pv BL 1.0830 26.00 9.06 0.181014 2'-6¼1.723 104 10'-0 26.00 5.6 21.556 7'-0 13 10'-0 23.279 9'-6¼ 120 Sprinkler, E(2'-0), T(5'-0) Pf Pe Pv BL 1.3800 52.20 11.20 0.201901 11'-0 3.432 13 10'-0 26.20 23.279 6'-0 0.000 11 10'-0 26.712 17'-0 120 Flow (q) from Route 2 T(6'-0) Pf Pe Pv BL 1.3800 80.71 17.31 0.452089 11'-4½5.146 11 10'-0 28.51 26.712 -0.000 8 10'-0 31.857 11'-4½ 120 Flow (q) from Route 3 Pf Pe Pv BL 1.6820 111.60 16.11 0.314089 11'-4½3.575 8 10'-0 30.89 31.857 0.000 9 10'-0 35.432 11'-4½ 120 Flow (q) from Route 7 Pf Pe Pv BL 1.6820 144.18 20.82 0.504522 0'-9½5.391 9 10'-0 32.59 35.432 9'-10¾-0.000 10 10'-0 40.824 10'-8¼ 120 Flow (q) from Route 9 T(9'-10¾) Pf Pe Pv BL 2.1570 266.09 23.36 0.466758 14'-3¾9.552 10 10'-0 121.90 40.824 6'-1¾ 7 10'-0 50.376 20'-5½ 120 Flow (q) from Route 4 E(6'-1¾) Pf Pe Pv BL 2.6350 266.09 15.65 0.176092 100'-5½32.196 7 10'-0 50.376 82'-4½0.434 3 9'-0 83.006 182'-10 120 4E(8'-2¾), 3T(16'-5¾) Pf Pe Pv BL 4.2600 266.09 5.99 0.016971 17'-0¾6.736 3 9'-0 83.006 26'-4 5.202 2 -3'-0 94.945 43'-4¾ 120 2E(13'-2), BFP(-5.000), PRV(-1.000) Pf Pe Pv UG 4.2800 266.09 5.93 0.016589 50'-0 2.483 2 -3'-0 94.945 99'-8¼-2.601 1 3'-0 94.827 149'-8¼ 120 BV(16'-2), 6E(13'-5¾), GV(2'-8¼), S 516.09 250.00 Hose Allowance At Source 1 • • • • • Route 2 • • • • • Pf Pe Pv BL 1.0490 26.20 9.73 0.214459 6'-5¾1.390 107 10'-0 26.20 5.6 21.890 13 10'-0 23.279 6'-5¾ 120 Sprinkler • • • • • Route 3 • • • • • Pf Pe Pv BL 1.0830 28.51 9.93 0.214611 1'-8¾0.799 102 10'-0 28.51 5.6 25.912 2'-0 0.000 11 10'-0 26.712 3'-8¾ 120 Sprinkler, E(2'-0) • • • • • Route 4 • • • • • Pf Pe Pv BL 1.0490 29.51 10.95 0.267219 6'-5¾3.068 108 10'-0 29.51 5.6 27.766 5'-0 14 10'-0 30.833 11'-5¾ 120 Sprinkler, T(5'-0) Pf Pe Pv BL 1.4420 59.80 11.75 0.209623 11'-5¼2.396 14 10'-0 30.30 30.833 15 10'-0 33.230 11'-5¼ 120 Flow (q) from Route 5 Pf Pe Pv BL 1.4420 121.90 23.95 0.782717 0'-9½3.526 15 10'-0 30.64 33.230 3'-8½ 12 10'-0 36.756 4'-6 120 Flow (q) from Route 6 E(3'-8½) Pf Pe Pv BL 1.6820 121.90 17.60 0.369822 11'-0 4.068 12 10'-0 36.756 10 10'-0 40.824 11'-0 120 • • • • • Route 5 • • • • • Pf Pe Pv BL 1.0830 30.30 10.55 0.240195 1'-6¼1.566 105 10'-0 30.30 5.6 29.267 5'-0 14 10'-0 30.833 6'-6¼ 120 Sprinkler, T(5'-0) • • • • • Route 6 • • • • • Pf Pe Pv BL 1.0490 30.64 11.38 0.286523 6'-5¾3.289 109 10'-0 30.64 5.6 29.940 5'-0 15 10'-0 33.230 11'-5¾ 120 Sprinkler, C(5'-0) • • • • • Route 7 • • • • • Pf Pe Pv BL 1.0830 30.89 10.76 0.249022 0'-8¾1.426 101 10'-0 30.89 5.6 30.432 5'-0 0.000 8 10'-0 31.857 5'-8¾ 120 Sprinkler, T(5'-0) • • • • • Route 8 • • • • • © M.E.P.CAD, Inc.5/26/2015 Page 6AutoSPRINK® VR11 v11.0.30.0 8:28:06AM Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: CS2662 - RETAIL Report Description: RETAIL UNIT 104 Pf Pe Pv BL 1.0830 31.46 10.96 0.257481 1'-6¼1.679 106 10'-0 31.46 5.6 31.551 5'-0 15 10'-0 33.230 6'-6¼ 120 Sprinkler, C(5'-0) • • • • • Route 9 • • • • • Pf Pe Pv BL 1.0830 32.59 11.35 0.274858 0'-8¾1.574 103 10'-0 32.59 5.6 33.859 5'-0 0.000 9 10'-0 35.432 5'-8¾ 120 Sprinkler, T(5'-0) 1.51 Pipe Type Legend AO Arm-Over BL Branch Line CM Cross Main DN Drain DR Drop DY Dynamic FM Feed Main FR Feed Riser MS Miscellaneous OR Outrigger RN Riser Nipple SP Sprig ST Stand Pipe UG Underground Units Legend Diameter Inch Elevation Foot Flow gpm Discharge gpm Velocity fps Pressure psi Length Foot Friction Loss psi/Foot HWC Hazen-Williams Constant Pt Total pressure at a point in a pipe Pn Normal pressure at a point in a pipe Pf Pressure loss due to friction between points Pe Pressure due to elevation difference between indicated points Pv Velocity pressure at a point in a pipe Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Ee1 11¼° Elbow Ee2 22½° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap 4.87 )(150 1.33 140 1.16 130 0.713 100 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter = Factor C Value Multiplier Value Of C Multiplying Factor © M.E.P.CAD, Inc.5/26/2015 Page 7AutoSPRINK® VR11 v11.0.30.0 8:28:06AM