Loading...
HomeMy WebLinkAboutF15-0045_F15-0045 product data_1435760820.pdf 7026 South Tucson Way Centennial, CO 80112 (303) 792-0022 Fax (303) 792-9049 Fire Sprinkler System Product Data Submittal For Chateau Christian Townhouses Unit #320 356 Hanson Ranch Road Vail, CO 81657 WSFP #CS2718 Prepared By: Nick Pippin Project Manager Western States Fire Protection Co. 7026 S. Tucson Way Centennial, CO 80112 Cell (720) 539-0494 Phone (303) 792-0022 Fax (303) 792-9049 Email: nick.pippin@wsfp.us June 25, 2015 Hydraulic Summary Report Description: Bedrooms Job Number: CS2718 Node Flow(gpm) Total Hose Streams 0.00 Safety MarginRequiredAvailable Node Hose Flow Static Residual Flow Total Demand (gpm)(psi)(psi)(gpm)(psi)(gpm)(psi)(psi)@@Name 1 132.578 90.748 41.830602.0077.000135.000 108.17Water Supply Design EngineerJob Number Total Water Required (Including Hose Allowance) 108.17 Maximum Pressure Unbalance In Loops 0.000 Additional Hose Supplies 0.00 Hose Allowance At Source Supplies 43.85gal Residential 0.100gpm/ft² 256.00ft² 1024.00ft² 4 Occupancy Area of Application Coverage Per SprinklerNumber Of Sprinklers Calculated Density Manually Flowing Job Suffix Volume capacity of Dry PipesVolume capacity of Wet Pipes 6.36 between nodes 1 and 2 Maximum Velocity Under Ground 28.86 between nodes 7 and 8 Maximum Velocity Above Ground 4.9 K-Factor 25.60 at 27.295 Most Demanding Sprinkler Data System Christiana Unit#320Vail, CO 81658 Job Site/Building Vail Fire Department356 Hanson Ranch Road AHJ 032Christian Townhouse Unit#320 Job State Certification/License NumberJob Name: Nick PippinCS2718 Contractor Contractor Number032 Name of Contractor: Western States Fire Protection Address 1 274 Center Drive Address 2 Glenwood Springs, CO. 81601 Contact Name Contact TitlePM ExtensionPhone FAX E-mail nick.pippin@wsfp.us Web-Site Nick Pippin Address 3 Address 1 Address 2 Drawing Name CS2718 -Christiana #320.cad System Flow Demand 108.17 Remote Area(s) Address 3 6/30/2015© M.E.P.CAD, Inc.Page 1AutoSPRINK® VR11 v11.0.30.0 4:05:53PM Hydraulic Graph Report Description: Bedrooms Job Number: CS2718 System Demand (Including Hose Allowance at Source) System Demand 77.000 @ 602.00 Residual: Pressure 135.000 Static: Pressure Water Supply at Node 1 Hydraulic Graph Water Supply at Node 1 90.748 @ 108.17 90.748 @ 108.17 Available Pressure at Time of Test 132.578 @ 108.17 © M.E.P.CAD, Inc.6/30/2015 Page 2AutoSPRINK® VR11 v11.0.30.0 4:05:55PM Device (gpm) Actual Flow Minimum Flow (gpm)(K) K-Factor (psi) Pressure (gpmpft2) Density Summary Of Outflowing Devices Report Description: Bedrooms Job Number: CS2718 Coverage (Foot) Sprinkler 101 25.74 25.60 4.9 27.586 0.101gpm/ft²256.00ft² Sprinkler 102 25.60 25.60 4.9 27.295 0.100gpm/ft²256.00ft² Sprinkler 103 27.29 25.60 4.9 31.019 0.107gpm/ft²256.00ft² Sprinkler 104 29.54 25.60 4.9 36.347 0.115gpm/ft²256.00ft² Most Demanding Sprinkler Data © M.E.P.CAD, Inc.6/30/2015 Page 3AutoSPRINK® VR11 v11.0.30.0 4:05:58PM Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: CS2718 Report Description: Bedrooms • • • • • Route 1 • • • • • Pf Pe Pv BL 1.0550 25.60 9.40 0.132243 6'-5¼1.381 102 26'-0 25.60 4.9 27.295 4'-0 9 26'-0 28.676 10'-5¼ 150 Sprinkler, E(2'-0), T(2'-0) Pf Pe Pv BL 1.0550 51.34 18.84 0.479083 8'-0¾4.817 9 26'-0 25.74 28.676 2'-0 8 26'-0 33.493 10'-0¾ 150 Flow (q) from Route 2 E(2'-0) Pf Pe Pv BL 1.0550 78.63 28.86 1.054218 3'-1½3.285 8 26'-0 27.29 33.493 0.000 7 26'-0 36.777 3'-1½ 150 Flow (q) from Route 3 Pf Pe Pv BL 1.2910 108.17 26.51 0.711603 26'-8¾23.293 7 26'-0 29.54 36.777 6'-0 5 26'-0 60.070 32'-8¾ 150 Flow (q) from Route 4 T(3'-0), cplg(1'-0), E(2'-0) Pf Pe Pv BL 2.0090 108.17 10.95 0.082592 10'-0 2.684 5 26'-0 60.070 22'-6 4 26'-0 62.754 32'-6 150 5E(3'-6), T(5'-0), BFP, f Pf Pe Pv ST 2.6350 108.17 6.36 0.033307 64'-5½12.970 4 26'-0 62.754 24'-8½15.173 3 -9'-0 90.898 89'-2 120 3E(8'-2¾), BFP(-10.000) Pf Pe Pv ST 2.4950 108.17 7.10 0.028755 4'-9¾1.710 3 -9'-0 90.898 2'-6 2 -9'-0 92.608 7'-3¾ 150 PRV(-1.500), BV, EE(2'-6) Pf Pe Pv UG 2.6350 108.17 6.36 0.033307 40'-0 1.607 2 -9'-0 92.608 8'-2¾-3.467 1 -1'-0 90.748 48'-2¾ 120 E(8'-2¾), S 108.17 0.00 Hose Allowance At Source 1 • • • • • Route 2 • • • • • Pf Pe Pv BL 1.0550 25.74 9.45 0.133546 4'-2 1.090 101 26'-0 25.74 4.9 27.586 4'-0 9 26'-0 28.676 8'-2 150 Sprinkler, E(2'-0), T(2'-0) • • • • • Route 3 • • • • • Pf Pe Pv BL 1.0550 27.29 10.02 0.148849 12'-7½2.474 103 26'-0 27.29 4.9 31.019 4'-0 8 26'-0 33.493 16'-7½ 150 Sprinkler, 2T(2'-0) • • • • • Route 4 • • • • • Pf Pe Pv BL 1.0550 29.54 10.84 0.172354 0'-6 0.431 104 26'-0 29.54 4.9 36.347 2'-0 7 26'-0 36.777 2'-6 150 Sprinkler, T(2'-0) 1.51 4.87 )(150 1.33 140 1.16 130 0.713 100 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter = Factor C Value Multiplier Value Of C Multiplying Factor © M.E.P.CAD, Inc.6/30/2015 Page 4AutoSPRINK® VR11 v11.0.30.0 4:06:02PM Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: CS2718 Report Description: Bedrooms Pipe Type Legend AO Arm-Over BL Branch Line CM Cross Main DN Drain DR Drop DY Dynamic FM Feed Main FR Feed Riser MS Miscellaneous OR Outrigger RN Riser Nipple SP Sprig ST Stand Pipe UG Underground Units Legend Diameter Inch Elevation Foot Flow gpm Discharge gpm Velocity fps Pressure psi Length Foot Friction Loss psi/Foot HWC Hazen-Williams Constant Pt Total pressure at a point in a pipe Pn Normal pressure at a point in a pipe Pf Pressure loss due to friction between points Pe Pressure due to elevation difference between indicated points Pv Velocity pressure at a point in a pipe Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Ee1 11¼° Elbow Ee2 22½° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap © M.E.P.CAD, Inc.6/30/2015 Page 5AutoSPRINK® VR11 v11.0.30.0 4:06:02PM BERMAD Fire Protection 700 Series Pressure Reducing Valve Model: FP 720-UL Typical Applications Features and Benefits ■ Minimized pressure loss ❑ Unobstructed flow path ❑ Advanced “Y”, or angle pattern ❑ Wide range flow V-Port Throttling Plug ■ Advanced pilot system with adjustable closing speed – Accurately maintains static and dynamic pressure ■ Double chambered unitized actuator ❑ Easy, in-line inspection ensures minimal down time ❑ Quick and smooth valve action ■ Replaceable stainless steel valve seat – Long valve life Optional Features ■ Large control filter (code: F) ■ Seawater service FS as prefix to model Note: Optional features can be mixed and matched. Consult your Bermad representative for full details. Hose station feeds Sprinkler systems with over pressure Deluge systems with over pressure Foam systems Fire hydrant water supply Description The Model FP 720-UL reduces high, unstable upstream pressure to maintain precise stable downstream pressure, regardless of changing upstream pressure or flow, and requires only existing line pressure to operate. BERMAD Fire Protection 700 SeriesFP 700E Flow & Hydraulic Data gpm Flow RatePressure Loss0.1 1.0 10 100 1,000 0.5 40 65 50 500 5,000 psi 15.0 12.5 10.0 7.5 5.0 2.5 1.5 50 75 100 250 500 750 1,000 2,500 20,00015,00010,0005,000 7,500 m3/h bar 11/2”21/2” 2” 50 80 3” 100 4” 150 6” 200 8” 250 10” 300 12” 350 14” 400 16” Flow Chart Flow Properties DN 40-50 65 80 100 150 200 250 300 350 400 Inch 1½"-2”2½"3"4"6"8"10"12"14"16"“Y”-TypeKv-Y 50 55 115 200 460 815 1,250 1,850 1,990 3,310 Cv-Y 58 64 133 230 530 940 1,440 2,140 2,300 3,820 K-Y 3.9 9.2 4.9 3.9 3.7 3.8 3.9 3.7 5.9 3.7 Leq-m, Y 10.3 33.4 21.6 23 37.5 53.9 70 85.6 159.9 112.7 Leq-feet, Y 33.8 109.5 70.8 75.6 123 176.9 229.5 280.8 524.5 369.6 AngleKv-A 55 61 127 220 506 897 1,375 2,035 2,189 3,641 Cv-A 64 70 146 250 580 1,040 1,590 2,350 2,530 4,210 K-A 3.2 7.6 4.0 3.2 3.1 3.1 3.2 3.1 4.9 3.0 Leq-m, A 8.5 27.6 17.8 19.0 37.0 44.6 57.8 70.7 132.1 93.1 Leq-feet, A 28 90.5 58.5 62.5 101.6 146.2 189.7 232 433.4 305.5 Valve flow coefficient, Kv or Cv Equivalent Pipe Length, Leq Flow resistance or Head loss coefficient, Cv = 1.155 Kv Where:Kv = Valve flow coefficient (flow in m3/h at 1bar Diff. Press.)Cv = Valve flow coefficient (flow in gpm at 1psi Diff. Press.)Q = Flow rate (m3/h ; gpm) ∆P = Differential pressure (bar ; psi) Gf = Liquid specific gravity (Water = 1.0) Kv(Cv)=Q Gf ∆P Leq=Lk.D K=∆H 2g V2Where:K = Flow resistance or Head loss coefficient (dimensionless) ∆H = Head loss (m ; feet)V = Nominal size flow velocity (m/sec ; feet/sec.)g = Acceleration of gravity (9.81 m/sec2 ; 32.18 feet/sec2) Where:Leq = Equivalent nominal pipe length (m ; feet)Lk = Equivalent length coefficient for turbulent flow in clean commercial steel pipe (SCH 40)D = Nominal pipe diameter (m; feet) Note: The Leq values given are for general consideration only. Actual Leq may vary somewhat with each of the valve sizes. 3 BERMAD Fire Protection 700 SeriesModel: FP 720-UL Engineer Specifications The Pressure Reducing Valve shall be UL Listed for fire protection. It shall eliminate downstream over-pressure, maintaining a constant downstream delivery pressure, regardless of varying pressures and/or flows. The main valve shall be a diaphragm actuated, “Y” pattern (or angle) valve. Valve actuation shall be accomplished by one moving assembly containing a double chambered actuator, which shall include a stainless steel stem and a resilient elastomeric seal held by a flat seal disk and creating a drip tight seal against the seat. The valve seat shall be removable and made of stainless steel. The seat bore net area shall be no less than that of the valve nominal diameter and shall have an unobstructed flow path with no stem guide or supporting ribs. All necessary inspection and servicing shall be possible in-line. The valve shall be UL-Listed as a pressure controlling water control valve. The Pressure Reducing Pilot Valve shall be UL-Listed as part of the assembly. The control trim shall be supplied as an assembly, pre-assembled and hydraulically tested at an ISO 9000 and 9001 certified factory. Valve Closed (static condition)Valve Open (flowing condition) Operation The BERMAD Model FP 720-UL, pilot operated pressure reducing valve automatically and accurately reduces downstream water pressure to a specific, adjustable value. The FP 720-UL operates under both flowing and non- flowing (static) conditions. The Pressure Reducing Pilot [1] senses downstream pressure [2] and in real time modulates the main valve [3] to maintain a constant downstream pressure. In no-flow static conditions, should the downstream pressure start rising above pilot setting, the pilot closes, shutting the main valve drip-tight sealing [4] to maintain the allowable downstream pressure. [4] [2][3] [1] BERMAD Fire Protection 700 SeriesModel: FP 720-UL System Components 1 - BERMAD Model FP 720-UL 2 - Pressure Relief Valve (BERMAD Model FP 730-UF) 3 - Isolating Valve 4 - Pressure Gauge 5 - Strainer Typical Installations Standard Pressure Reducing System Installation Considerations ■ Allow enough room around the valve assembly for any future maintenance. ■ Install isolating valves upstream and downstream of the valve system. ■ Install the valve horizontally with the cover facing up. ■ Install a UL-Listed relief valve (recommended: BERMAD Model FP 730-UF) of the appropriate size on the downstream side of the FP 720-UL, as required by NFPA-20 standard. ■ Install a UL-Listed pressure gauge on both sides of the valve. Parallel Pressure Reducing System ■ Wide flow range ■ Redundant safety ■ Serviceable with zero down time Two-Stage Pressure Reducing System ■ High pressure differential ■ Added reduced pressure zone protection 4 1 25 4 3 3 UL Listed The BERMAD Model FP 720-UL is UL-Listed when installed as a unit. BERMAD Fire Protection TwLy1, Ly2, Ly3 La1, La2, La3 R1R2R3 h1h2h3 Th Th Tw Size 1½”2”2½”3”4”6”8”10”12”14”16” mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch DimensionsLy1 (1)205 81/16 205 81/16 209 81/4 250 97/8 320 125/8 415 163/8 500 1911/16 605 2313/16 725 289/16 733 287/8 990 39 Ly2 (2)155 61/8 155 61/8 212 83/8 250 913/16 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Ly3 (3)210 81/4 210 81/4 212 83/8 264 107/16 335 131/4 433 171/16 524 205/8 637 25 762 30 767 303/16 1,024 403/4 La1 (1)121 43/4 121 43/4 140 51/2 152 6 190 71/2 225 87/8 265 107/16 320 125/8 396 159/16 400 153/4 450 173/4 La2 (2)120 43/4 120 43/4 140 51/2 159 61/4 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A La3 (3)127 5 127 5 149 57/8 159 61/4 200 77/8 234 93/16 277 107/8 336 131/4 415 165/16 419 161/2 467 183/8 h1 (1)82 31/4 82 31/4 102 4 102 4 127 5 152 6 203 8 219 85/8 275 1013/16 275 1013/16 369 141/2 h2 (2)82 31/4 82 31/4 102 4 114 41/2 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A h3 (3)89 31/2 89 31/2 109 45/16 108 41/4 135 55/16 165 61/2 216 81/2 235 91/4 294 111/2 294 111/2 386 53/16 R1 (1)75 215/16 83 31/4 93 35/8 100 315/16 114 41/2 140 51/2 171 63/4 203 8 241 91/2 267 101/2 298 113/4 R2 (2)40 19/16 40 19/16 48 17/8 55 21 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A R3 (3)78 31/16 83 31/4 95 33/4 108 41/4 127 5 159 61/4 191 71/2 222 83/4 260 101/4 292 111/2 324 123/4 Tw 191 71/2 191 71/2 191 71/2 207 81/16 242 91/2 290 117/16 325 1213/16 370 149/16 515 201/4 525 2011/16 610 24 Th 312 125/16 312 125/16 312 125/16 364 141/2 405 1515/16 505 20 566 225/16 639 253/16 449 1711/16 449 1711/16 541 215/16 Model: FP 720-UL Technical Data Connection Standard • Grooved: ANSI/AWWA C606 for 2, 3, 4, 6 & 8” • Flanged: ANSI B16.42 (Ductile Iron), B16.5 (Steel & Stainless Steel), B16.24 (Bronze), ISO PN16 • Threaded: NPT or BSP 2, 2½ & 3” Water Temperature • 0.5 - 80°C (33 - 180°F) Sizes (“Y” & Angle) • Available Y: 1½ - 20” • Angle: 1½ – 18” • 24-36” Globe • UL-Listed: 2, 2½, 3, 4, 6 & 8” Pressure Rating • UL-Listed 2 - 6” : 300 psi (21 bar) 8” to : 175 psi (12 bar) • Max. for Class#150: 250 psi (17 bar) • Max. for Class#300: 400 psi (28 bar) • Max. for Grooved ends: 400 psi (28 bar) • Setting range: 30 - 165 psi (2 - 11.5 bar) • Test pressure: 450 psi (31 bar) Manufacturers Standard Materials Main valve body and cover • Ductile Iron ASTM A-536 Main valve internals • Stainless Steel & Elastomer Control Trim System • Brass control components/accessories • Stainless Steel 316 tubing & fittings Elastomers • Polyamide fabric reinforced Polyisoprene, NR Coating • Electrostatic Powder Coating Polyester, Red (RAL 3002) Optional Materials Main valve body/internals • Carbon Steel ASTM A-216-WCB • Stainless Steel 316 • Ni-Al-Bronze ASTM B-148 • Titanium • Duplex • Hastalloy Control Trim • Stainless Steel 316 • Monel® and Al-Bronze • Hastalloy C-276 Coating • High Build Epoxy Fusion-Bonded with UV Protection, Anti-Corrosion Approvals • UL Listed for: Special system water control valves (VLMT), Pressure Reducing and Pressure Control type for Fire Protection Systems. • ABS • Lloyd’s Registered Notes:1. Ly1 for ANSI#150, ISO PN16 & Grooved ends (see available sizes below) 2. La1 & h1 for Angle body, ANSI#150 and ISO PN16.3. Ly2, La2 & h2 for threaded female, NPT or BSP. 4. Ly3, La3 & h3 for flanged ANSI #300 and ISO PN25. 5. Data is for maximum envelope dimensions, component positioning may vary.6. Provide adequate space around valve for maintenance. bermadfire@bermad.com • www.bermad.com The information herein is subject to change without notice. BERMAD shall not be held liable for any errors. All rights reserved. © Copyright by BERMAD. PE7PE-2UL 11 700 Series ES-A-C400/C400N/C400Z Features • Extremely Compact Design • 70% Lighter than Traditional Designs • 304 (Schedule 40) Stainless Steel Housing & Sleeve • Groove Fittings Allow Integral Pipeline Adjustment • Patented Link Check Provides Lowest Pressure Loss • Unmatched Ease of Serviceability • Available with Grooved Butterfly Valve Shutoffs • May be Used for Horizontal or N Pattern Installations • Replaceable Check Disc Rubber Job Name ________________________________________________Contractor ______________________________________________ Job Location ______________________________________________Approval _______________________________________________ Engineer _________________________________________________Contractor’s P.O. No. ______________________________________ Approval _________________________________________________Representative ___________________________________________ C400 OSY C400N BFG Ames product specifications in U.S. customary units and metric are ap prox i mate and are provided for reference only. For pre cise mea sure ments, please contact Ames Technical Service. Ames reserves the right to change or mod i fy product design, con struc tion, specifications, or ma te ri als without pri or notice and without incurring any obligation to make such changes and mod i fi ca tions on Ames products pre vi ous ly or sub se quent ly sold. The Colt C400, C400N, C400Z Reduced Pressure Zone Assemblies provide protection to the potable water system from contamination in accordance with national plumbing codes. The Colt C400, C400N, C400Z are normally used in health hazard applications for protection against backsiphonage, backpressure and the fouling of either check valve. Specifications The Colt C400, C400N, C400Z Reduced Pressure Zone Assemblies shall consist of two independent Link Check modules, a differential pressure relief valve located between and below the two modules, two drip tight shutoff valves, and required test cocks. Link Check modules and relief valve shall be contained within a sleeve accessible single housing constructed from 304 (Schedule 40) stainless steel pipe with groove end connections. Link Checks shall have reversible elastomer discs and in operation produce drip tight closure against the reverse flow of liquid caused by backpressure or backsiphonage. Assembly shall be Colt C400, C400N, C400Z as manufactured by the Ames Company. ColtTM Series C400, C400N, C400Z Reduced Pressure Zone Assemblies Sizes: 21⁄2" – 10" (65 – 250mm) www.amesfirewater.com IMPORTANT: INQUIRE WITH GOVERNING AUTHORITIES FOR LOCAL IN STAL LA TION RE QUIRE MENTS LEAD FREE* * The wetted surface of this product contacted by consumable water contains less than one quarter of one percent (0.25%) of lead by weight. Approvals For additional approval information please contact the factory or visit our website at www.amesfirewater.com Dimensions — Weights Configurations • Horizontal • “Z” pattern horizontal • “N” pattern horizontal Materials • Housing & Sleeve: 304 (Schedule 40) Stainless Steel • Elastomers: EPDM, Silicone and Buna ‘N’ • Link Checks: Noryl®, Stainless Steel • Check Discs: Reversible Silicone or EPDM • Test Cocks: Bronze Body Nickel Plated • Pins & Fasteners: 300 Series Stainless Steel • Springs: Stainless Steel Noryl® is a registered trademark of SABIC Innovative PlasticsTM. C400 Size (DN) DimeNSiONS weiGht A C (OSY) C (NRS) D G H I J M P C400 C400N NRS OSY NRS OSY in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. lbs. kgs. lbs. kgs. lbs. kgs. 21⁄2 65 31 787 163⁄8 416 93⁄8 238 61⁄2 165 291⁄16 738 22 559 151⁄2 393 813⁄16 223 219⁄16 548 93⁄16 234 118 54 128 58 126 57 136 62 3 80 3111⁄16 805 187⁄8 479 101⁄4 260 611⁄16 170 301⁄4 768 223⁄4 578 171⁄8 435 93⁄16 233 231⁄8 587 101⁄2 267 134 61 148 67 147 67 161 73 4 100 3311⁄16 856 223⁄4 578 123⁄16 310 7 178 33 838 24 610 181⁄2 470 915⁄16 252 261⁄2 673 113⁄16 284 164 74 164 74 187 85 187 85 6 150 431⁄2 1105 301⁄8 765 16 406 81⁄2 216 443⁄4 1137 333⁄4 857 233⁄16 589 131⁄16 332 323⁄4 832 15 381 276 125 298 135 317 144 339 154 8 200 50 1270 373⁄4 959 1915⁄16 506 911⁄16 246 541⁄8 1375 405⁄8 1032 277⁄16 697 1511⁄16 399 371⁄8 943 173⁄16 437 441 200 483 219 516 234 558 253 10 250 571⁄2 1460 453⁄4 1162 2313⁄16 605 113⁄16 285 66 1676 50 1270 321⁄2 826 175⁄16 440 463⁄8 1178 20 508 723 328 783 355 893 405 950 431 A D C (open) G h J i P m Pressure — Temperature Tem per a ture Range: 33°F – 110°F (0.5°C – 43°C) Maximum Working Pres sure: 175psi (12.06 bar) Note: When installing a drain line on Series C400 backflow preventer use 400/500 air gap. See ES-A-AG/EL/TC for additional information. Available Models Suffix: NRS - non-rising stem resilient seated gate valves OSY - UL/FM outside stem and yoke resilient seated gate valves BFG - UL/FM grooved gear operated butterfly valves with tamper switch *OSY FxG - Flanged inlet gate connection and grooved outlet gate connection *OSY GxF - Grooved inlet gate connection and flanged outlet gate connection *OSY GxG - Grooved inlet gate connection and grooved outlet gate connection Available with grooved NRS gate valves - consult factory* Post indicator plate and operating nut available - consult factory* *Consult factory for dimensions B64.51013 m G h J i P C400N BFG/C400Z BFG Size (DN) DimeNSiONS weiGht G H I J M P C400N, C400Z in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 21⁄2 65 321⁄2 826 231⁄2 597 151⁄2 394 91⁄2 241 2113⁄16 555 1113⁄16 300 67 30 3 80 34 864 241⁄2 622 165⁄16 414 101⁄16 256 231⁄8 587 121⁄8 308 70 32 4 100 355⁄8 905 26 660 173⁄16 437 1015⁄16 279 2415⁄16 634 125⁄8 321 87 39 6 150 461⁄2 1181 3512⁄16 908 201⁄2 521 131⁄2 343 281⁄4 718 15 382 160 73 . Dimensions — Weights C400 BFG Size (DN) DimeNSiONS weiGht A C D P in. mm in. mm in. mm in. mm in. mm lbs. kgs. 4 100 2911⁄16 754 73⁄4 197 63⁄8 162 91⁄2 241 66 30 6 150 373⁄4 959 911⁄16 246 77⁄16 189 141⁄4 362 122 55 A C D P Capacity - C400 BFG * = Rated Flow ** = UL Tested USC 6" C400BFG PSID USC 4" C400BFG PSID 6" Colt BFG 0 2 4 6 8 10 12 14 16 02004006008001000120014001600Flow (GPM) 4" Colt BFGs 0 5 10 15 20 25 0 100 200 300 400 500 600 700800 kPa psi 172 25 138 20 103 15 69 10 34 5 0 0 0 100 200 300 400 500 600 700 800 gpm 0 380 760 1140 1520 1900 2280 2680 3040 lpm 15 fps 4.6 mps 4" (100 mm) USC 6" C400BFG PSID USC 4" C400BFG PSID 6" Colt BFG 0 2 4 6 8 10 12 14 16 02004006008001000120014001600Flow (GPM) 4" Colt BFGs 0 5 10 15 20 25 0 100 200 300 400 500 600 700800 kPa psi 110 16 96 14 83 12 69 10 55 8 41 6 28 4 14 2 0 0 0 200 400 600 800 1000 1200 1400 1600 gpm 0 760 1520 2280 3040 3800 4560 5300 6060 lpm 15 fps 4.6 mps 6" (150 mm) ****** ES-A-C400/C400N/C400Z 0935 © 2009 Ames Fire & Waterworks kPa psi 124 18 110 16 96 14 83 12 69 10 55 8 41 6 kPa psi 124 18 110 16 96 14 83 12 69 10 55 8 41 6 kPa psi 110 16 96 14 83 12 69 10 55 8 41 6 28 4 0 50 100 150 200 250 300 350 gpm0 190 380 570 760 950 1140 1330 lpm 15 fps 4.6 mps kPa psi 110 16 96 14 83 12 69 10 55 8 41 6 kPa psi 179 26 152 22 124 18 96 14 69 10 41 6 0 100 200 300 400 500 gpm 0 380 760 1140 1520 1900 lpm 15 fps 4.6 mps 21⁄2" (65mm) 3" (80mm) * 0 300 600 900 1200 1500 gpm0 1140 2280 3420 4560 5700 lpm 15 fps 4.6 mps 6" (150mm) 0 500 1000 1500 2000 2500 gpm 0 1900 3800 5700 7600 9500 lpm 15 fps 4.6 mps 8" (200mm) 0 100 200 300 400 500 600 700 800 gpm 0 380 760 1140 1520 1900 2280 2660 3040 lpm 15 fps 4.6 mps 4" (100mm) 0 500 1000 1500 2000 2500 3000 3500 gpm0 1900 3800 5700 7600 9500 11400 13300 lpm fps mps 10" (250mm) * * * * * kPa psi 124 18 110 16 96 14 83 12 69 10 55 8 41 6 Z N H Z N H N Z H NZ H N Z H N Z H ** ** ** ** ** ** Capacity UL/FM Certified Flow CharacteristicsN&Z Flow characteristics collected using butterfly shutoff valves. See literatue S-Colt-400, 500 for gate valve flow characteristics * = Rated Flow ** = UL Tested Horizontal N - Pattern Z - Pattern www.amesfirewater.com A Watts Water Technologies Company USA: Backflow- 1427 N. Market Blvd • Suite #9 • Sacramento, CA 95834 • T: 916-928-0123 • F: 916-928-9333 Control Valves- 18550 Hansen Road • Houston, TX 77075 • T: 713-943-0688 • F: 713-944-9445 Canada: 5435 North Service Rd. • Burlington, ONT. L7L 5H7• T: 905-332-4090 • F: 905-332-7068