HomeMy WebLinkAboutF15-0050_F15-0050 cut sheets 1_1438619100.pdfEQUIPMENT SUBMITTAL 401 Beaver Dam Circle Beaver Dam Residence - Unit B FIRE PROTECTION Vail, Colorado www.meridianfire.com Meridian Intermountain PO Box 3940; Avon, Colorado 81629 CO LIC #1391 PHONE (970) 827-9120 PRODUCT MAKE MODEL / DESCRIPTION 1. SPRINKLERS TYCO Series LFII Concealed Pendent SIN #TY3596 White Flat Plate TYCO Series LFII Residential Pendent SIN #TY2234 White w/White 2-Pc Esc 2. PIPE AQUATHERM PP-R FS, SDR 7, 4 Plastic 3. PIPE FITTINGS AQUATHERM Fusion Type Compatible to Pipe 4. HANGERS AFCON Model 510 CPVC Hanger AFCON Model 511 CPVC Hanger AFCON Model 513 CPVC Hanger AFCON Model 514 CPVC Hanger AFCON Model 515 CPVC Hanger AFCON Model 519 CPVC Hanger 5. VALVES AMES Model 2000B Double Check BFP FPPI Bronze 3-Way Valve FPPI Bronze Chack Valve 6. ELECTRICAL DEVICES POTTER VSR-S Waterflow Switch POTTER SASH Horn & Strobe 7. FIRE DEPT CONN GUARDIAN Model 6014 2-1/2" Single Outlet FDC GUARDIAN Model 6431 1/2" Automatic Ball Drip 8. MISCELLANEOUS FPPI Sprinkler Gauge FPPI Spare Sprinkler Cabinet FPPI Indentification Signs FPPI 2-Piece Adjustable Escutcheon Beaver Dam Residence - Unit B 401 Beaver Dam Circle FIRE PROTECTION EQUIPMENT SUBMITTAL INDEX Vail, Colorado **The above listed items are the proposed equipment to be used on this project, however we reserve the right to use an 'equivalent' product or manufacturer at our discretion. RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinklers, Flat Plate Wet Pipe and Dry Pipe Systems Page 1 of 6 FEBRUARY 2014 TFP442 IMPORTANTAlways refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal-lation of sprinkler systems and com-ponents. Improper handling and in-stallation can permanently damage a sprinkler system or its compo-nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Worldwide Contacts www.tyco-fire.com General Description The TYCO RAPID RESPONSE Se-ries LFII Residential 4.9 K-factor Con-cealed Pendent Sprinklers (TY3596) are decorative, fast response, fus-ible solder sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels. The cover plate assembly conceals the sprinkler operating components above the ceiling. The flat profile of the cover plate provides the optimum aes-thetically appealing sprinkler design. In addition, the concealed design of the Series LFII Residential Concealed Pendent Sprinklers (TY3596) provides 1/2 inch (12,7 mm) vertical adjustment. This adjustment provides a measure of flexibility when cutting fixed sprinkler drops. The Series LFII Residential Concealed Sprinklers are intended for use in the following scenarios: • wet and dry pipe residential sprin-kler systems for one- and two-fam-ily dwellings and mobile homes per NFPA 13D • wet and dry pipe residential sprin-kler systems for residential occu-pancies up to and including four stories in height per NFPA 13R • wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 The Series LFII Residential Concealed Pendent Sprinklers (TY3596) has been designed with heat sensitivity and wa-ter distribution characteristics proven to help in the control of residential fires and to improve the chance for occu-pants to escape or be evacuated. The Series LFII Residential Concealed Pendent Sprinklers (TY3596) are shipped with a Disposable Protective Cap. The Protective Cap is temporar-ily removed for installation, and then it can be replaced to help protect the sprinkler while the ceiling is being in-stalled or finished. The tip of the Pro-tective Cap can also be used to mark the center of the ceiling hole into plas-ter board, ceiling tiles, etc. by gently pushing the ceiling product against the Protective Cap. When the ceiling installation is complete the Protective Cap is removed and the Cover Plate Assembly installed. Dry Pipe System ApplicationThe Series LFII Residential Concealed Pendent Sprinklers offers a laboratory approved option for designing dry pipe residential sprinkler systems, whereas, most residential sprinklers are labora-tory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Concealed Pendent Sprinklers (TY3596) need not be increased over the number of de-sign sprinklers (hydraulic design area) as specified for wet pipe sprinkler sys-tems, as is accustomed for density/area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Residen-tial Concealed Pendent Sprinklers of-fer the features of non-water filled pipe in addition to not having to increase the number of design sprinklers (hy-draulic design area) for systems de-signed to NFPA 13, 13D, or 13R. NOTICE The Series LFII Residential Con-cealed Pendent Sprinklers (TY3596) described herein must be installed and maintained in compliance with this document and with the applica-ble standards of the National Fire Pro-tection Association, in addition to the standards of any authorities having ju-risdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain-ing their fire protection system and de-vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number TY3596 TFP442Page 2 of 6 3-3/16" DIA. (81,0 mm) 1/2" NPT 2-1/2" DIA.(63,5 mm) MOUNTINGSURFACE3/16"(4,8 mm) 1/8" GAP (3,2 mm) FACE OF SPRINKLER FITTING 7/8" (22,2 mm) 1-1/8" (28,6 mm) TIP DEFLECTOR IN OPERATED POSITION 1/2" (12,7 mm) THREADED ADJUSTMENT SPRINKLER-SUPPORT CUPASSEMBLY OPERATEDSPRINKLER 1-7/8"±1/4" (47,6 mm ±6,4 mm) SPRINKLER-SUPPORT CUPASSEMBLY COVER-RETAINERASSEMBLY COVERPLATERETAINER DISPOSABLE PROTECTIVE CAP WRENCHRECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA SPRINKLER/SUPPORT CUPASSEMBLY COVER PLATE/RETAINERASSEMBLY COVER PLATE EJECTIONSPRING RETAINER WITH THREAD DIMPLES SOLDER TAB SEALINGASSEMBLY COMPRESSION SCREW DEFLECTOR(OPERATEDPOSITION) SPRINKLER WRENCHING AREA SOLDER LINK ELEMENT LEVER DEFLECTOR CAP BODY(1/2" NPT) SADDLE SUPPORT CUP WITH ROLL FORMED THREADS GUIDE PIN GUIDE PINHOUSING THREAD INTO SUPPORT CUP UNTIL MOUNTING SURFACE IS FLUSH WITH CEILING FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER (TY3596) FIGURE 2 W-TYPE 18 SPRINKLER WRENCH FIGURE 3 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER (TY3596) INSTALLATION DIMENSIONS/PROTECTIVE CAP/ACTIVATED DEFLECTOR TFP442Page 3 of 6 Dry Pipe System Water DeliveryWhen using the Series LFII Residen-tial Concealed Pendent Sprinklers (TY3596) in dry pipe sprinkler systems, the time for water delivery must not ex-ceed 15 seconds for the most remote operating sprinkler. Obstruction to Water DistributionSprinklers are to be located in accor-dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described with-in the Technical Data Sheet TFP490. Operational SensitivityThe sprinklers are to be installed rela-tive to the ceiling mounting surface as shown in Figure 3. Sprinkler SpacingThe minimum spacing between sprin-klers is 8 feet (2,4 m). The maximum spacing between sprinklers cannot ex-ceed the length of the coverage area (Ref. Table A or B) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). The Series LFII must not be used in applications where the air pressure above the ceiling is greater than that below. Down drafts through the Sup-port Cup could delay sprinkler opera-tion in a fire situation. Technical Data ApprovalsUL and C-UL Listed. NYC Approved under MEA 44-03-E-2NSF. Certified to NSF/ANSI 61. The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers are only listed with the Se-ries LFII Concealed Cover Plates hav-ing a factory-applied finish. These Cover Plates and their part numbers can be found in the Ordering Procedure section at the end of this data sheet. Maximum Working Pressure175 psi (12,1 bar) Discharge CoefficientK = 4.9 GPM/psi1/2 (70,6 LPM/bar1/2) Temperature Rating160°F (71°C) Sprinkler with 139°F (59°C) Cover Plate Vertical Adjustment1/2 inch (12,7 mm) FinishesRefer to Ordering Procedure section Physical Characteristics Body..............................Brass Cap..............................Bronze Saddle ............................Brass Sealing Assembly . . . . . . . . . . . . . . . . Beryllium Nickel w/ TEFLON Soldered Link Halves. . . . . . . . . . . . . . . . .Nickel Lever.............................Bronze Compression Screw . . . . . . . . . . . . . . . . . Brass Deflector..................Copper or Brass Guide Pin Housing.......Bronze Guide Pins .........Stainless Steel or Bronze Support Cup . . . . . . . . . . . . . . . . . . . . . . . .Steel Cover Plate .......................Copper Retainer ...........................Brass Cover Plate Ejection Spring. . . . .Stainless Steel Operation When exposed to heat from a fire, the Cover Plate, which is normally sol-dered to the Support Cup at three points, falls away to expose the Sprin-kler Assembly. At this point the De-flector supported by the Arms drops down to its operated position. The fus-ible link of the Sprinkler Assembly is comprised of two link halves that are soldered together with a thin layer of solder. When the rated temperature is reached, the solder melts and the two link halves separate allowing the sprin-kler to activate and flow water. Design Criteria The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers (TY3596) are UL and C-UL Listed for installation in accordance with this section. Note: When conditions exist that are outside the scope of the provided cri-teria, refer to the Residential Sprinkler Design Guide TFP490 for the manu-facturer's recommendations that may be acceptable to the authority having jurisdiction. System TypesPer the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 about the use of residential sprinklers in residential dry pipe systems. Ceiling TypesSmooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13 as applicable. Hydraulic Design (NFPA 13D and 13R)For systems designed to NFPA 13D or NFPA 13R, the minimum re quired sprinkler flow rates are given in Ta-bles A and B as a function of tem-perature rating and the maximum allowable coverage areas. The sprin-kler flow rate is the minimum re-quired discharge from each of the total number of “design sprinklers” as specified in NFPA 13D or NFPA 13R. The number of “design sprinklers” specified in NFPA 13D and 13R for wet pipe systems is to be applied when designing dry pipe systems. Hydraulic Design (NFPA 13)For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis-charge from each of the four sprinklers is to be the greater of the following: • The flow rates given in Tables A and B as a function of temperature rating and the maximum allowable coverage area. • A minimum discharge of 0.1 gpm/ft2 over the “design area” comprised of the four most hydraulically demanding sprinklers for actual coverage areas protected by the four sprinklers. The number of “design sprinklers” specified in NFPA 13 for wet pipe sys-tems is to be applied when designing dry pipe systems. TFP442Page 4 of 6 Maximum Coverage Area (a) Ft. x Ft. (m x m) Maximum Spacing Ft. (m) WET PIPE SYSTEM Minimum Flow and Residual Pressure(b, c) Ordinary Temp. Rating 160°F (71°C)Deflector to Ceiling Installation Type Minimum Spacing Ft. (m) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3,7 x 3,7)12 (3,7)13 (49,2) 7.0 (0,48)Smooth Ceilings 7/8 to 1-1/8 inches Beamed Ceilings per NFPA 13D or 13R, or 13. Installed in beam 7/8 to 1-1/8 inches below bottom of beam Concealed 8(2,4) 14 x 14 (4,3 x 4,3)14 (4,3)13 (49,2) 7.0 (0,48) 16 x 16 (4,9 x 4,9)16 (4,9)13 (49,2)7.0 (0,48) 18 x 18 (5,5 x 5,5)18 (5,5)17 (64,3)12.0 (0,83) 20 x 20 (6,1 x 6,1)20 (6,1)20 (75,7)16.7 (1,15) (a) For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. (c) For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area of the flow in accordance with the criteria in this table must be used. Maximum Coverage Area(a) Ft. x Ft. (m x m) Maximum SpacingFt. (m) DRY PIPE SYSTEM Minimum Flow and Residual Pressure (b, c) Ordinary Temp. Rating 160°F (71°C)Deflector to Ceiling Installation Type Minimum Spacing Ft. (m) Flow GPM (L/min) Pressure PSI (bar) 12 x 12(3,7 x 3,7)12(3,7)13 (49,2) 7.0 (0,48)Smooth Ceilings 7/8 to 1-1/8 inches Beamed Ceilings per NFPA 13D or 13R, or 13. Installed in beam 7/8 to 1-1/8 inches below bottom of beam Concealed 8(2,4) 14 x 14(4,3 x 4,3)14(4,3)14 (53,0)8.2 (0,57) 16 x 16(4,9 x 4,9)16(4,9)15 (56,8)9.4 (0,65) 18 x 18(5,5 x 5,5)18(5,5)18 (68,1)13.5 (0,93) 20 x 20(6,1 x 6,1)20(6,1)21 (79,5)18.4 (1,27) (a) For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. (c) For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area of the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT-PLATE CONCEALED PENDENT SPRINKLER (TY3596) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TABLE B DRY PIPE SYSTEM RAPID RESPONSE SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT-PLATE CONCEALED PENDENT (TY3596) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TFP442Page 5 of 6 Step 6. Screw on the Cover Plate As-sembly until its flange comes in con-tact with the ceiling. Do not continue to screw on the Cover Plate Assembly such that it lifts a ceil-ing panel out of its normal position. If the Cover Plate Assembly cannot be engaged with the Mounting Cup or the Cover Plate Assembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. Care and Maintenance The TYCO RAPID RESPONSE Se-ries LFII Residential Concealed Pen-dent Sprinklers (TY3596) must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection sys-tem must be obtained from the prop-er authorities and all personnel who may be affected by this action must be notified. Absence of a Cover Plate may de-lay the sprinkler operation in a fire situation. When properly installed, there is a nominal 1/8 inch (3,2 mm) air gap be-tween the lip of the Cover Plate and the ceiling, as shown in Figure 3. This air gap is necessary for proper op-eration of the sprinkler by allowing heat flow from a fire to pass below and above the Cover Plate to help as-sure appropriate release of the Cover Plate in a fire situation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be re-placed, if necessary, by factory paint-ed units. Non-factory applied paint may adversely delay or prevent sprin-kler operation in the event of a fire. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leak-ing or exhibiting visible signs of corro-sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi-fied or over heated sprinklers must be replaced. Care must be exercised to avoid dam-age -before, during, and after installa-tion. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. The owner is responsible for the in-spection, testing, and maintenance of their fire protection system and devic-es in compliance with this document, as well as with the applicable stan-dards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authori-ties having jurisdiction. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. The owner must assure that the sprin-klers are not used for hanging any ob-jects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non-operation in the event of a fire or inad-vertent operation may result. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor-dance with local requirements and/or national codes. Installation The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers (TY3596) must be installed in accordance with this section. General InstructionsDamage to the fusible Link Assembly during installation can be avoided by handling the sprinkler by the support cup only (i.e., do not apply pressure to the fusible Link Assembly). A 1/2 inch NPT sprinkler joint should be obtained with a minimum to maxi-mum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque may distort the sprinkler inlet with conse-quent leakage or impairment of the sprinkler. Do not attempt to compensate for in-sufficient adjustment in the Cover Plate/Retainer Assembly by under-or over-tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must only be in-stalled in the pendent position and with the centerline of the sprinkler per-pendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap-plied to the pipe threads, and using the W-Type 18 Wrench shown in Figure 2, install and tighten the Sprinkler/Sup-port Cup Assembly into the fitting. The W-Type 18 Wrench will accept a 1/2 inch ratchet drive. Step 4. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. The Protec-tive Cap helps prevent damage to the Deflector and Guide Pins during ceil-ing installation and/or during applica-tion of the finish coating of the ceil-ing. It may also be used to locate the center of the clearance hole by gen-tly pushing the ceiling material against the center point of the Cap. Note: As long as the protective Cap remains in place, the system is consid-ered to be “Out Of Service”. Step 5. After the ceiling has been completed with the 2-1/2 inch (63 mm) diameter clearance hole and in prep-aration for installing the Cover Plate Assembly, remove and discard the Protective Cap, and verify that the De-flector moves up and down freely. If the Sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire Sprin-kler assembly. Do not attempt to modi-fy or repair a damaged sprinkler. GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 TFP442Page 6 of 6 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of The DuPont Corporation. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure When placing an order, indicate the full product name. Contact your local distributor for availability. Sprinkler AssemblySpecify: Series LFII (TY3596), K = 4.9, Residential Concealed Pendent Sprin-kler without Cover Plate Assembly, P/N 51-112-1-160 Cover Plate AssemblySpecify: Cover Plate Assembly hav-ing a (specify) finish for the Series LFII (TY3596), K = 4.9, Residential Concealed Pendent Sprinkler, P/N (specify): Ivory (RAL1015) ...........P/N 56-202-0-135 Beige (RAL1001)...........P/N 56-202-2-135 Pure White (b) (RAL9010) ...P/N 56-202-3-135 Signal White (a) (RAL9003) ..P/N 56-202-4-135 Grey White (RAL9002)......P/N 56-202-5-135 Brown (RAL8028)..........P/N 56-202-6-135 Black (RAL9005) ..........P/N 56-202-7-135 Brushed Brass............P/N 56-202-8-135 Brushed Chrome ..........P/N 56-202-9-135 Custom Paint .............P/N 56-202-X-135 (a) Previously known as Bright White. (b) Eastern Hemisphere sales only. Note: All Custom Cover Plates are painted using Sherwin Williams Interior Latex Paint. Contact TYCO Customer Service with any questions related to custom orders. Sprinkler WrenchSpecify: W-Type 18 Sprinkler Wrench, P/N 56-000-1-265 RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Pendent Wet Pipe and Dry Pipe Systems Page 1 of 6 FEBRUARY 2014 TFP400 Worldwide Contacts www.tyco-fire.com IMPORTANTAlways refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal-lation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. General Description The TYCO RAPID RESPONSE Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) are decorative, fast response, frangible bulb sprinklers designed for use in residential occu-pancies such as homes, apart-ments, dormitories, and hotels. When aesthetics and optimized flow charac-teristics are the major consideration, the Series LFII Residential Sprinklers (TY2234) should be the first choice. The Series LFII Residential Sprinklers are intended for use in the following scenarios: • wet and dry pipe residential sprin-kler systems for one- and two-family dwellings and mobile homes per NFPA 13D • wet and dry pipe residential sprin-kler systems for residential occu-pancies up to and including four stories in height per NFPA 13R • wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 The recessed version of the Series LFII Residential Sprinklers is intended for use in areas with finished ceilings. It employs a two-piece Style 20 Recessed Escutcheon. The Recessed Escutcheon provides 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush ceiling position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the pipe drops to the sprinklers must be cut. The Series LFII Residential Sprinklers have been designed with heat sensi-tivity and water distribution charac-teristics proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System ApplicationThe Series LFII Residential Pendent and Recessed Pendent Sprinklers offers a laboratory approved option for designing dry pipe residential sprinkler systems, whereas, most residential sprinklers are laboratory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) need not be increased over the number of design sprinklers (hydraulic design area) as specified for wet pipe sprinkler systems, as is accustomed for density/area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Residential Sprinklers offer the features of non-water filled pipe in addition to not having to increase the number of design sprinklers (hydraulic design area) for systems designed to NFPA 13, 13D, or 13R. NOTICE The Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) described herein must be installed and maintained in compliance with this document and the applicable stan-dards of the National Fire Protection Association, in addition to the stan-dards of any authorities having jurisdic-tion. Failure to do so may impair the performance of these devices. The owner is responsible for main-taining their fire protection system and devices in proper operating condi-tion. Contact the installing contractor or sprinkler manufacturer with any questions. Sprinkler Identification Number (SIN) TY2234 Technical Data ApprovalsUL Listed for use with wet pipe and dry pipe systems C-UL Listed for use only with wet pipe systems NSF Certified to NSF/ANSI 61 For details on these approvals, refer to the Design Criteria section. Maximum Working Pressure175 psi (12,1 bar) Discharge CoefficientK = 4.9 GPM/psi1/2 (70,6 LPM/bar1/2) Temperature Rating155°F (68°C) or 175°F (79°C) FinishesNatural BrassPure or Signal WhiteChrome Plated Physical Characteristics Frame.............................Brass Button............................Copper Sealing Assembly . . . . . . . . . . . . . . . . Beryllium Nickel w/TEFLON Bulb (3 mm) ........................ Glass Compression Screw . . . . . . . . . . . . . . . . Bronze Deflector..........................Bronze Ejection Spring...............Stainless Steel TFP400Page 2 of 6 Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and flow water. Design Criteria The TYCO RAPID RESPONSE Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) are UL and C-UL Listed for installation in accordance with this section. Residential Sprinkler Design GuideWhen conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturer’s recommendations that may be acceptable to the local authority having jurisdiction. System TypesPer the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 for the use of residential sprinklers in residential dry pipe systems. Ceiling TypesSmooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13 as applicable. Hydraulic Design (NFPA 13D and 13R)For systems designed to NFPA 13D or NFPA 13R, the minimum re quired sprinkler flow rates are SURFACE ESCUTCHEON PLATE SEATING 1-5/8"(41,3 mm) -2 Button Temperaturerating is indicated on Deector. Deector Compression Screw BulbSealing Assembly -6 * -4 5 - 3 - * * 6 4 5 1 3 2 Components: Frame1- 1/2"NPT 7/16" (11,1 mm) MAKE-IN NOMINAL ESCUTCHEON STYLE 20 RECESSEDWRENCH (57,2 mm)2-1/4" FLATS (73,0 mm)2-7/8" DIA. CROSS SECTION PENDENT RECESSED PENDENT TY2234 2-7/8" DIA.(73,0 mm) (57,2 mm)2-1/4" DIA. MOUNTING SPRINKLER CLOSURE SURFACE FITTING FACE OF (11,1±3,2 mm)7/16±1/8" MOUNTING PLATE 1-3/8" (34,9 mm) 1-1/8" (28,6 mm) (3,2 mm)1/8" 1/2" (12,7 mm) 1/4" (6,4 mm)WRENCH RECESS(END "A" USEDFOR TY2234) RECESS WRENCH WITH SPRINKLER ENGAGEMENTIN TO ENSURE WRENCHING AREA PUSH WRENCH FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) FIGURE 3 W-TYPE 6 SPRINKLER WRENCH FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE RAPID RESPONSE SERIES LFII RESIDENTIAL PENDENT SPRINKLER (TY2234) TFP400Page 3 of 6 given in Tables A and B as a func-tion of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of “design sprinklers” as specified in NFPA 13D or NFPA 13R. The number of “design sprinklers” specified in NFPA 13D and 13R for wet pipe systems is to be applied when designing dry pipe systems. Hydraulic Design (NFPA 13)For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in Tables A or B as a function of temperature rating and the maximum allowable coverage area. • A minimum discharge of 0.1 gpm/ft2 over the “design area” comprised of the four most hydraulically demanding sprinklers for actual coverage areas protected by the four sprinklers. The number of “design sprinklers” specified in NFPA 13 for wet pipe systems is to be applied when designing dry pipe systems. Dry Pipe System Water DeliveryWhen using the Series LFII Residential Sprinklers (TY2234) in dry pipe sprin-kler systems, the time for water delivery must not exceed 15 seconds for the most remote operating sprinkler. Obstruction to Water DistributionSprinklers are to be located in accor-dance with the obstruction rules of NFPA 13D, 13R, and 13 as appli-cable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational SensitivitySprinklers are to be installed with a deflector-to-ceiling distance of 1-1/4 to 4 inches. Sprinkler SpacingThe minimum spacing between sprin-klers is 8 feet (2,4 m). The maximum spacing between sprinklers cannot exceed the length of the coverage area (Table A or B) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). Installation The TYCO RAPID RESPONSE Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) must be installed in accor-dance with this section: General InstructionsDo not install any bulb type sprin-kler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diam-eter of the air bubble is approximately 1/16 inch (1,6 mm). A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprin-kler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutcheon Plate by under- or over- tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series LFII Residential Pendent SprinklersThe Series LFII Residential Pendent Sprinklers must be installed in accor-dance with the following instructions. Step 1. Install pendent sprinklers in the pendent position with the deflector parallel to the ceiling. Step 2. With pipe thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Series LFII Residential Recessed Pendent SprinklersThe Series LFII Residential Recessed Pendent Sprinklers must be installed in accordance with the following instructions. Step A. Install recessed pendent sprinklers in the pendent position with the deflector parallel to the ceiling. Step B. After installing the Style 20 Mounting Plate over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 4). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step D. After the ceiling has been installed or the finish coat has been applied, slide on the Style 20 Closure over the Series LFII Residential Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFP400Page 4 of 6 Maximum Coverage Area (a) Ft. x Ft. (m x m) DRY PIPE SYSTEM Minimum Flow and Residual Pressure(b, c) Ordinary Temp. Rating 155°F (68°C)Intermediate Temp. Rating 175°F (79°C)Deflector to Ceiling Installation Type Minimum Spacing Ft. (m)Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12(3,7 x 3,7)13 (49,2)7.0 (0,48)13 (49,2)7.0 (0,48)Smooth Ceilings 1-1/4 to 4 inches Beamed Ceilings per NFPA 13D or 13R 1-1/4 to 1-3/4 inches below bottom of beam. Recessed using Style 20 Escutcheon or non-recessed per NFPA 13D, 13R, or 13 8(2,4) 14 x 14(4,3 x 4,3)14 (53,0)8.2 (0,57)14 (53,0)8.2 (0,57) 16 x 16(4,9 x 4,9)15 (56,8)9.4 (0,65)15 (56,8)9.4 (0,65) 18 x 18(5,5 x 5,5)18 (68,1)13.5 (0,93)18 (68,1)13.5 (0,93) 20 x 20(6,1 x 6,1)21 (79,5)18.4 (1,27)21 (79,5)18.4 (1,27) (a) For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. (c) For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area of the flow in accordance with the criteria in this table must be used. Max. Coverage Area (a) Ft. x Ft. (m x m) WET PIPE SYSTEM Minimum Flow and Residual Pressure(b, c) Ordinary Temp. Rating 155°F (68°C)Intermediate Temp. Rating 175°F (79°C)Deflector to Ceiling Installation Type Minimum Spacing Ft. (m)Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3,7 x 3,7)13 (49,2)7.0 (0,48)13 (49,2)7.0 (0,48)Smooth Ceilings 1-1/4 to 4 inches Beamed Ceilings per NFPA 13D or 13R 1-1/4 to 1-3/4 inches below bottom of beam. Recessed using Style 20 Escutcheon or non-recessed per NFPA 13D, 13R, or 13 8(2,4) 14 x 14 (4,3 x 4,3)13 (49,2)7.0 (0,48)13 (49,2)7.0 (0,48) 16 x 16 (4,9 x 4,9)13 (49,2)7.0 (0,48)13 (49,2)7.0 (0,48) 18 x 18 (5,5 x 5,5)17 (64,3)12.0 (0,83)17 (64,3)12.0 (0,83) 20 x 20 (6,1 x 6,1)20 (75,7)16.7 (1,15)20 (75,7)16.7 (1,15) (a) For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. (c) For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area of the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TABLE B DRY PIPE SYSTEM SERIES LFII RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TFP400Page 5 of 6 Care and Maintenance The TYCO RAPID RESPONSE Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) must be maintained and serviced in accordance with this section: Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprinklers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; other-wise, non-operation in the event of a fire or inadvertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other-wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers - before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and mainte-nance of their fire protection system and devices in compliance with this document, as well as with the appli-cable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authorities having jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler AssemblySpecify: Series LFII (TY2234), K = 4.9, Residential Pendent Sprinkler, (specify) temperature rating, (specify) finish, P/N (specify): 155°F (68°C) Natural Brass..............P/N 51-201-1-155Pure White (RAL 9010)* ......P/N 51-201-3-155Signal White (RAL 9003) .....P/N 51-201-4-155Chrome Plated.............P/N 51-201-9-155 175°F (79°C) Natural Brass..............P/N 51-201-1-175Pure White (RAL 9010)* ......P/N 51-201-3-175Signal White (RAL 9003) .....P/N 51-201-4-175Chrome Plated.............P/N 51-201-9-175 *Eastern Hemisphere sales only Recessed EscutcheonSpecify: Style 20 Recessed Escutcheon with (specify*) finish, P/N (specify*) *Refer to Technical Data Sheet TFP770 Sprinkler WrenchSpecify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 TFP400Page 6 of 6 Copyright © 2014 Tyco Fire Products, LP. All rights reserved.TEFLON is trademark of The DuPont Corporation. Worldwide Contacts www.tyco-fire.com General Description The TYCO RAPID RESPONSE Series LFII Residential Horizontal Sidewall Sprinklers (TY2334) are decorative, fast response, frangible bulb sprin-klers designed for use in residential occupancies such as homes, apart-ments, dormitories, and hotels. When aesthetics and optimized flow charac-teristics are the major consideration, the Series LFII Residential Sprinklers (TY2334) should be the first choice. The Series LFII Residential Sprinklers are intended for use in the following scenarios: • wet pipe residential sprinkler systems for one-and two-family dwellings and mobile homes per NFPA 13D • wet pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R • wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 The recessed version of the Series LFII Residential Sprinklers is intended for use in areas with finished walls. It employs a two-piece Style 20 Recessed Escutcheon. The Recessed Escutcheon provides 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush mounting surface position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the pipe nipples to the sprinklers must be cut. The Series LFII Residential Sprinklers has been designed with heat sensitivity and water distribution characteristics proven to help in the control of residen-tial fires and to improve the chance for occupants to escape or be evacuated. NOTICE The Series LFII Residential Horizontal Sidewall Sprinklers (TY2334) described herein must be installed and maintained in compliance with this document and with the applicable standards of the National Fire Protection Association, in addition to the standards of any author-ities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main-taining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY2334 Technical Data ApprovalsUL and C-UL Listed NSF Certified to NSF/ANSI 61 For details on approvals, refer to the Design Criteria section. Maximum Working PressureMaximum 175 psi (12,1 bar) Discharge CoefficientK= 4.4 GPM/psi1/2 (63,4 LPM/bar1/2) Temperature Rating155°F (68°C) or 175°F (79°C) FinishesNatural BrassSignal White Chrome Plated Physical CharacteristicsFrame....................BrassButton...................BronzeSealing Assembly. . . . . . . . .Beryllium Nickel w/ TEFLONBulb .................3 mm GlassCompression Screw. . . . . . . . BronzeDeflector.................Copper RAPID RESPONSE Series LFII Residential Sprinklers 4.4 K-factor Horizontal Sidewall Wet Pipe Systems Page 1 of 6 APRIL 2013 TFP412 IMPORTANT Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Worldwide Contacts www.tyco-fire.com Sealing-3 54 * 6 Compression of Deector. is indicated on top Temperature rating Bulb Deector- -- * 1 Components: 2 Button Frame- -WRENCH STYLE 20RECESSED ESCUTCHEON FLATS 2-7/8" DIA. RECESSED (73,0 mm)5 NOMINAL PLATE SEATINGSURFACE ESCUTCHEON MAKE-IN CENTERLINE OF WATERWAY 7/16" (11,1 mm) (54,0 mm) (38,1 mm) DEFLECTORBOSS (11,1 mm)7/16" END-OF- 2-1/8" 1-1/2" DEFLECTOR TOP-OF- 4 26* 1 3 Assembly Screw TOP1/2" NPT FLATSWRENCH FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS (TY2334) 1-1/4" (31,8 mm) 1" (25,4 mm) MOUNTING PLATE TY2334 MOUNTINGSURFACE CLOSURE (73,0 mm) 1/2" (12,7 mm) (57,2 mm)2-1/4" DIA. 1/4" (6,4 mm) 1/8"(3,2 mm) (11,1±3,2 mm) SPRINKLER FITTING FACE OF 7/16±1/8" 2-7/8" DIA. BOSS END-OF-DEFLECTOR TOP-OF-DEFLECTOR 7/16"(11,1 mm) FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE RAPID RESPONSE SERIES LFII RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER (TY2334) WRENCH RECESS(END "A" USED FOR TY2334) FIGURE 3 W-TYPE 6 SPRINKLER WRENCH RECESS WRENCH WITH SPRINKLER ENGAGEMENT IN TO ENSURE WRENCHING AREA PUSH WRENCH FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH TFP412Page 2 of 6 Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb allowing the sprinkler to activate and flow water. Design Criteria The TYCO RAPID RESPONSE Series LFII (TY2334) Residential Horizontal Sidewall Sprinklers are UL and C-UL Listed for installation in accordance with this section. Residential Sprinkler Design GuideWhen conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturer’s recommendations that may be accept-able to the local authority having jurisdiction. System TypeOnly wet pipe systems may be utilized. Ceiling TypeSmooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13 as applicable. Hydraulic Design (NFPA 13D and 13R)For systems designed to NFPA 13D or NFPA 13R, the minimum required sprinkler flow rate are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of “design sprinklers” as specified in NFPA 13D or NFPA 13R. Hydraulic Design(NFPA 13)For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in Table A as a function of temperature rating and the maximum allowable coverage area. • A minimum discharge of 0.1 gpm/ft2 over the “design area” comprised of the four most hydrau-lically demanding sprinklers for the actual coverage areas being protected by the four sprinklers. Obstruction to Water DistributionSprinklers are to be located in accor-dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational SensitivityThe sprinklers are to be installed with an end of defector-boss to wall distance of 1-1/8 to 6 inches. In addition the top-of-deflector-to-ceiling distance is to be within the range (Ref. Table A) being hydraulically calculated. Sprinkler SpacingThe minimum spacing between sprin-klers is 8 feet (2,4 m). The maximum spacing between sprinklers cannot exceed the width of the coverage area (Ref. Table A) being hydraulically calcu-lated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 16 feet for a 16 ft. x 20 ft. coverage area). Installation The TYCO RAPID RESPONSE Series LFII (TY2334) Residential Horizontal Sidewall Sprinklers must be installed in accordance with this section. General InstructionsDo not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm). A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the sprinkler by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series LFII Residential Horizontal Sidewall SprinklersThe Series LFII Horizontal Sidewall Sprinklers must be installed in accor-dance with the following instructions. Step 1. Horizontal sidewall sprin-klers are to be installed in the hori-zontal position with their centerline of waterway perpendicular to the back wall and parallel to the ceiling. The word “TOP” on the Deflector is to face towards the ceiling with the front edge of the Deflector parallel to the ceiling. Step 2. With pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 3). With reference to Figure 1, the W-Type 6 Sprinkler Wrench is to be applied to the wrench flats. Series LFII Residential Recessed Horizontal Sidewall SprinklersThe Series LFII Recessed Horizontal Sidewall Sprinklers must be installed in accordance with the following instructions. Step A. Recessed horizontal side-wall sprinklers are to be installed in the horizontal position with their center-line of waterway perpendicular to the back wall and parallel to the ceiling. The word “TOP” on the Deflector is to face towards the ceiling. Step B. After installing the Style 20 Mounting Plate over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 4). With reference to Figure 1, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step D. After the wall has been installed or the finish coat has been applied, slide on the Style 20 Closure over the Series LFII Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the wall. TFP412 Page 3 of 6 TABLE A WET PIPE SYSTEMSSERIES LFII (TY2334) RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS NFPA 13D, 13R AND 13 WET PIPE HYDRAULIC DESIGN CRITERIA Max. Coverage Area (a) Width x Length (d) Ft. x Ft. (m x m) Max. Spacing Ft. (m) WET PIPE SYSTEM Minimum Flow and Residual Pressure(b, c) Ordinary Temp. Rating 155°F (68°C) Intermediate Temp. Rating 175°F (79°C)Deflector to Ceiling Installation Type Minimum Spacing Ft. (m) Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3,7 x 3,7)12 (3,7)13 (49,2)8.7 (0,60)13 (49,2)8.7 (0,60) 4 to 6 inches Recessed using Style 20 Escutcheon or non-recessed per NFPA 13D, 13R, or 13 8(2,4) 14 x 14 (4,3 x 4,3)14 (4,3)14 (53,0)10.1 (0,70)14 (53,0)10.1 (0,70) 16 x 16 (4,9 x 4,9)16 (4,9)16 (60,6)13.2 (0,91)16 (60,6)13.2 (0,91) 16 x 18 (4,9 x 5,5)16 (4,9)19 (71,9)18.6 (1,28)19 (71,9)18.6 (1,28) 16 x 20 (4,9 x 6,1)16 (4,9)23 (87,1)27.3 (1,88)23 (87,1)27.3 (1,88) 18 x 18 (5,5 x 5,5)18 (5,5)23 (87,1)27.3 (1,88)23 (87,1)27.3 (1,88) 18 x 20 (5,5 x 6,1)18 (5,5)26 (98,4)34.9 (2,41)26 (98,4)34.9 (2,41) 12 x 12 (3,7 x 3,7)12 (3,7)13 (49,2)8.7 (0,60)13 (49,2)8.7 (0,60) 6 to 12 inches 14 x 14 (4,3 x 4,3)14 (4,3)14 (53,0)10.1 (0,70)14 (53,0)10.1 (0,70) 16 x 16 (4,9 x 4,9)16 (4,9)17 (64,3)14.9 (1,03)17 (64,3)14.9 (1,03) 16 x 18 (4,9 x 5,5)16 (4,9)20 (75,7)20.7 (1,43)20 (75,7)20.7 (1,43) 16 x 20 (4,9 x 6,1)16 (4,9)23 (87,1)27.3 (1,88)23 (87,1)27.3 (1,88) 18 x 18 (5,5 x 5,5)18 (5,5)23 (87,1)27.3 (1,88)23 (87,1)27.3 (1,88) 18 x 20 (5,5 x 6,1)18 (5,5)26 (98,4)34.9 (2,41)26 (98,4)34.9 (2,41) (a) For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. (c) For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area or the flow in accordance with the criteria in this table must be used. (d) The Width x Length dimension refers to the Width (backwall where the sprinkler is located) times the Length (horizontal throw of sprinkler). TFP412Page 4 of 6 Care and Maintenance The TYCO RAPID RESPONSE Series LFII (TY2334) Residential Horizontal Sidewall Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for main-tenance work on the fire protection system which it controls, permission to shut down the affected fire protec-tion system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of an Escutcheon Plate may delay the sprinkler operation in a fire situation. The owner must assure that the sprin-klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non-operation in the event of a fire or inad-vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers - before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). The owner is responsible for the inspection, testing, and mainte-nance of their fire protection system and devices in compliance with this document, as well as with the appli-cable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The installing contractor or sprinkler manu-facturer should be contacted relative to any questions. Automatic sprinkler systems are recom-mended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Ordering Procedure Contact your local distributor for avail-ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler AssemblySpecify: Series LFII (TY2334), K=4.4, Residential Horizontal Sidewall Sprinkler, (specify) temperature rating, (specify) finish, P/N (specify). 155°F (68°C) Natural Brass..............P/N 51-215-1-155 Signal White (RAL9003)......P/N 51-215-4-155 Chrome Plated.............P/N 51-215-9-155 175°F (79°C) Natural Brass..............P/N 51-215-1-175 Signal White (RAL9003)......P/N 51-215-4-175 Chrome Plated.............P/N 51-215-9-175 Recessed EscutcheonSpecify: Style 20 Recessed Escutcheon with (specify*) finish, P/N (specify*). * Refer to Technical Data Sheet TFP770. Sprinkler WrenchSpecify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TFP412 Page 5 of 6 TFP412Page 6 of 6 Copyright © 2013 Tyco Fire Products, LP. All rights reserved.TEFLON is trademark of The DuPont Corporation. GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 aquatherm state of the pipe aquatherm red Pipe system made of polypropylene for fire sprinkler systems Edition: 05.2014 2 Our sales and delivery conditions (January 2014) and the contacts of our technical sales and distribution see on our homepage www.aquatherm.de. Subject to technical alterations, errors and misprints excepted. With the edition of this catalogue, all former ones become void. 3 Dear customers and partners, thank you for your interest in our family enterprise. For a long time the classification of enterprises as a family has rather been hidden than actively marketed. Only in recent years family enterprises experience a comeback. From employee perspective, they are generally a flat hierarchy, provide independent and responsible work under a cooperative management style, but above all they are considered safe employers who commit permanently to their employees. By definition, family enterprises are distinguished primarily by the unity of ownership and management in the hands of a family; this criterion the aquatherm group still meets after the transition from the first to the second generation (pictured above). Our self-image of a family enterprise, however, clearly exceeds this description. Our claim describes a proactive organization that bases in the responsible contact in everyday life, that challenges encouraging, thereby accompanies developments in a promoting way and sets on a personal influenced by nearby corporate culture. If these business properties meet determined people that daily inspire through initiative, diligence and passion, until we speak of a living family enterprise, until we speak with pride of the aquatherm family. We look forward to presenting you on the following pages some insight into our colorful, slightly green-tinted aquatherm world! Gerhard Rosenberg President of the Advisory Board Dirk Rosenberg Managing Director Maik Rosenberg Managing Director Christof Rosenberg Managing Director 1973Founding of aquatherm by Gerhard Rosenberg1978Transfer to the first factory in Biggen / D-Attendorn1985Completion of factory 1 in Biggen / D-Attendorn1992Founding of the branch in Radeberg near D-Dresden1996Founding of the metal processing company aquatherm metal, D-Attendorn1998Founding of a subsidiary in Carrara / Italy1999Completion of the main site in D-Attendorn as one complex (Factories 1+2, Production and Store,Laboratory and Training Centre)2001Completion of the extension Factory 2 in D-Attendorn2001Opening of the new training centre in D-Radeberg2002Completion of the logistics centre in D-Attendorn2003Completion of rebuilding and finishing of the training centre in D-Attendorn200330 year celebration of the company aquatherm2005Adding of 2 storeys on the administration building2005/06Completion of the 4-storey hallon the premises in AttendornBasement: StoreGround floor: Assembly / Packing1st Floor: Laboratory and Technical department2 nd Floor: Special manifold construction 2008 Aquisition of the former storehouse of the forwarding agent Kost, which also accomodates the room of the plant mainten-ace.2009 Opening of the new expertise centre for technical application.201340 year celebration of the company aquatherm 3 4 SERVICE Fair aquatherm is represented on all important fairs relevant for the sa- nitary and heating sector in Germa- ny or abroad with its own exhibition booth. For more information regar- ding fairs near to you, please visit internet page: www.aquatherm.de. Training service In addition to training service through the merchant network aquatherm offers its customers trai- ning, free of charge, at its training centres at Attendorn and Radeberg. Field staff In addition to the regular training service at Attendorn and Radeberg aquatherm field staff are available to assist customers, on site, throug- hout Germany. TECHNICAL HOTLINE+49 (0)2722 950 200 info@aquatherm.de www.aquatherm.de { { Parent plant Attendorn aquatherm GmbH Biggen 5 D-57439 Attendorn Phone: +49 (0)2722 950 0 Fax: +49 (0)2722 950 100 Subsidiary Radeberg aquatherm GmbH Wilhelm-Rönsch-Str. 4 D-01454 Radeberg Phone: +49 (0) 3528 4362-0 Fax: +49 (0) 3528 4362-30 SeRvice ManagementSystemISO 9001:2008ISO 14001:2004ISO 50001:2011 www.tuv.comID 0091005348 5 Miscellaneous Different aquatherm - CD`s, pros- pects, catalogues, poster, leaflets, mailings,calen-dars, a.s.m. are in- vestigated and produced from the internal advertising department. All information regarding the company, the technology, the products, the various trainings and fairs as well as all catalogues in pdf - form can be called and downloaded from the aquatherm - website: www.aquatherm.de. Software-Service The aquatherm - software service provides Datanorm-files, an inde- pendent graphical program (liNear), and the appropriate training. Laboratory The aquatherm laboratory: from the testing of granulate through to the finished product the customer can be assured of only the highest qua- lity products. Subsidiary Radeberg aquatherm GmbH Wilhelm-Rönsch-Str. 4 D-01454 Radeberg Phone: +49 (0) 3528 4362-0 Fax: +49 (0) 3528 4362-30 ceRTiFicATionS in AccoRdAnce wiTH iSo 9001, 14001 & 50001 Since 1996 aquatherm has been meeting the requirements of the certifiable quality management system according to DIN ISO 9001. The 2012 TÜV certificate was extended by the environmental management system according to ISO 14001 and currently by the energy management system according to ISO 50001. This success is a great contribution and represents a further step to strengthen our competitive position and to meet the high requirements and the responsiblity for our customers, partners and the environment.     SeRvice SERVICE 6 General 8-12 - Material properties / Advantages 8 - Processing 10 - International approvals 11 - Handling / Transport / Storage 12 Products 13-32 - Pipe / Socket - Reducer / Elbow - Tee / Cross - Sprinkler outlet / End cap / Weld-in saddle - Weldable flange adapter / Plastic flange / Coupling screw joint - Transition piece / Transition elbow - Threaded branch tee / Transition joint Transition piece for slot connection - Weld-in saddle / Pipe cutter - Welding device - Welding accessories - Welding tool / Drill Fusion 33-43 - Part A: Mounting of the tools 33 Heat-up phase 34 Handling 34 Guidelines 34 - Part B: Checking of devices and tools 35 Preparation for the fusion 36 Heating of pipe and fittings 37 Setting and alignment 37 - Visual inspection of fusion seam 38 - Part C: Weld-in saddles 40 Drilling, heat-up, joining, fixing 41 - Part D: Welding machine 42 - Part E: Welding machine light 43 - Part F: Repair 43 - Part G: Butt-welding of pipe dimension 160mm 44 Visual inspection of fusion seam (butt welding) 46 Welding parameters 48 TAbLe oF conTenTS conTenT 7 TAbLe oF conTenTS Laying of aquatherm red pipe in the concrete 49-57 - Part 1: Connecting of pipe work to the sprinkler outlet 49 - Part 2: Pressure test of pipe work installation as strength test and leak test 55 - Part 3: What must be considered during the concreting process? 55 - Part 4: Access to connection of the pipe work in concrete 56 - Part 5: Bridging of building joints 57 - Part 6: Potential equalizing 57 - Part 7: Pressurizing in the aquatherm red pipe-supply during the concreting process 57 - Part 8: Influence of the concrete to the applied compounds 57 Test 58-62 - Leakage test / Pressure diagram - Test record aquatherm red pipe system installation - Form: “Enquiry for the chemical resistance“ References 63-78 conTenT aquatherm red red 8 AdvAnTAGeS -certified and quality inspected -connection by fusion welding -resistant against corrosion and chemicals -no accumulation of corrosion products -low pipe roughness factor and high abrasion resistance -heat and sound-insulating characteristics -high impact strength -leak-proof connection of pipe and fitting by fusion technique -not easily flammable acc. to DIN 4102-1, building material class B1 -low weight compared to metal pipes -short processing time -no gaskets - sealing elements are not required -3-layer pipe with fibre glass reinforced inner layer -concealed fire protection -reduction of structural works costs by laying in concrete -weld-in saddle aquatherm red pipe offers an extensive range of pipes and fittings for the installation of fire sprinkler systems. The system is based on a fibre reinforced polypropylene pipe (faser composite pipe) produced in a multi-layer extrusion process. The material fusiolen® PP-R FS, used for the pipe production, is a plastic whose properties are designed for the special demands of the fields of appli- cation. Both, the installer´s request for easier processing and the demand for maximum safety in later application was regarded during the development. aquatherm red pipe is: - connection by fusion welding No sealants or adhesives are required for this permanent connection - corrosion-proof Prevents the clogging of the sprinkler with corrosive material. This ensures a long, low-maintenance service life as well as failure-free functioning of the system. The production of pipes and fittings is controlled according to the highest quality standards on most modern injection moulding machines and extrusi- on lines. The high quality of our products is guaranteed by extensive controls of incoming goods and the production process. The aquatherm quality management system is certified according to DIN EN ISO 14001:2004, 9001:2008 and 50001:2011. GeneRAL red 9 By the fusion of pipe and fitting the plastic melts to a homogeneous ma- terial unit. Pipe and fitting are heated quickly with specially provided welding tools and joined together - finished! Double material thickness at the joint – giving double safety at the other- wise critical point of a pipe system. A permanent leakproof connection is created with the aquatherm fusion technique. PRoceSSinG Fusion technique GeneRAL PP-R layer Faser layer PP-R layer 10 PRoceSSinG weld-in saddle technique Branches can easily be made by weld-in saddles, even post-installation. Material costs and processing time are reduced by using weld-in saddles. Whereas in case of tees three joints are to be processed, work is limited to mounting the saddle and the branch pipe only. Simply drill the pipe; heat up the saddle, pipe wall and surface; connect the parts. Finished! GeneRAL 11 Fire protection requirements and standards for planning and construction of sprinkler systems vary locally. Thus, the application of aquatherm red pipe in any case has to be agreed and coordinated with the local national fire protection authorities, the constructor and the building insurers. Further certification either national or local are in process. inTeRnATionAL APPRovALS for the application as sprinkler lines Iceland Spain Germany Great Britain Russia Poland Czech Republic VeriFire New Zeeland ZÚS ® Turkey Austria Australia Norway Hong Kong Philippines New Zeeland GeneRAL FEDERAL STATE ESTABLISHMENT THE ALL-RUSSIAN RESEARCH INSTITUTE FOR FIRE PROTECTION (FGU VNIIPO) 11 12 curaflam collar by Doyma conlit pipe wraps by Rockwool Transport and storage aquatherm red pipe-pipes can be stored in all outside temperatures. Pipes should be stored and transported flat and fully supported along their length. Bending pressures are to be avoided. High impact should be avoided at ex- ternely low temperatures. Although aquatherm red pipe-pipes are extremely robust, it is recommended to treat the material always with care. UV resistance Pipes from fusiolen® PP-R FS should not be installed (without protection) where subject to UV-radiation. All aquatherm red pipe-pipes and fittings are supplied in UV-protected packaging to bridge transport and assembly time. Ultraviolet rays have an influence on all high polymeric plastics. Hence, pipes should not be stored unprotected outside for a long time. The maximum sto- rage time is (outside) 6 months. Fire bulkheading All fire prevention systems which can prove equivalent licensing are suited for the aquatherm red pipe system. Procedures for additional repair Cut out damaged / leaking section and replace as for a new installation or repair with pipe repair stick (page 43). Chemical resistance On account of the special material qualities aquatherm red pipe-pipes and fittings provide extensive chemical resistance. aquatherm red pipe-transition connections and elements with brass inserts are not suitable for all media. The compatibility should be asked at aquatherm with media deviating from water. Please, use the “Enquiry for the chemical resistance” on page 62. Pipe friction loss The pressure loss caused by friction is to be calculated hydraulically with the Hazen-Williams-formula. The value to be used for C is 150, applicable for calculations of sprinkler installations and water supply. Equivalent lengths for the aquatherm red pipe sprinkler pipe system The equivalent lengths of transition pieces, threaded connexions and tees (flow direction: straight) can be edequated with the socket values. HanDling Pipe dimension Pipe series SDR 7,4 SDR 7,4 SDR 7,4 SDR 7,4 SDR 7,4 SDR 7,4 SDR 7,4 SDR 7,4 SDR 7,4 SDR 11 Outer diameter aquatherm red pipe 25,0 mm 32,0 mm 40,0 mm 50,0 mm 63,0 mm 75,0 mm 90,0 mm 110,0 mm 125,0 mm 160,0 mm article Equivalent pipe length in (m) Socket 0,22 0,30 0,40 0,52 0,70 0,86 1,07 1,36 1,58 2,44 Reduction of 1dimension 0,27 0,37 0,48 0,63 0,83 1,03 1,28 1,63 1,90 2,93 Reduction of 2 dimensions 0,36 0,49 0,64 0,84 1,11 1,37 1,71 2,17 2,53 3,91 Elbow < 90° - 45° 0,67 0,91 1,20 1,57 2,09 2,57 3,20 4,07 4,74 7,33 Elbow < 45° 0,33 0,46 0,60 0,78 1,04 1,28 1,60 2,03 2,37 3,66 Standard tee or cross flow direction branch 0,98 1,34 1,76 2,30 3,06 3,76 4,70 5,96 6,96 10,75 gEnERal 13 conlit pipe wraps by Rockwool PRodUcTS Material: PP-R FS Pipe series: SDR 7,4 Packing Unit: straight length á 6 m colour: red/4 green stripes aquatherm red pipe PiPe SdR 7,4 / b1 Art.-no.dimension dn PU m/pc Price m/pc diameter d [mm] wall thickness s [mm] internal diameter di [mm] water content [l/m] weight [kg/m] 4170708 20 x 2,8 mm 10 120 20 2,8 14,4 0,152 0,158 4170710 25 x 3,5 mm 15 120 25 3,5 18 0,236 0,246 4170712 32 x 4,4 mm 20 60 32 4,4 23,2 0,379 0,394 4170714 40 x 5,5 mm 25 60 40 5,5 29 0,590 0,613 4170716 50 x 6,9 mm 32 30 50 6,9 36,2 0,919 0,955 4170718 63 x 8,6 mm 40 30 63 8,6 45,8 1,444 1,500 4170720 75 x 10,3 mm 50 18 75 10,3 54,4 2,054 2,135 4170722 90 x 12,3 mm 65 12 90 12,3 65,4 2,943 3,058 4170724 110 x 15,1 mm 80 6 110 15,1 79,8 4,403 4,576 4170726 125 x 17,1 mm 90 6 125 17,1 90,8 5,669 5,891 aquatherm red pipe PiPe SdR 11 / b1 Art.-no.dimension dn PU m/pc Price m/pc diameter d [mm] wall thickness s [mm] internal diameter di [mm] water content [l/m] weight [kg/m] 4170130 160x14,6 mm 125 6 160 14,6 130,8 15,792 4,360 PiPe, FiTTinGS aquatherm red pipe SockeT / b1 Art.-no.dimension PU m/pc Price m/pc Price eURo d l z d weight [kg/m] 4111008 20 mm 10 1 20 16 1,5 29,5 0,011 4111010 25 mm 10 1 25 17,5 1,5 34 0,018 4111012 32 mm 5 1 32 20,3 2,3 43 0,027 4111014 40 mm 5 1 40 23,8 3,3 52 0,043 4111016 50 mm 5 1 50 26,5 3 68 0,087 4111018 63 mm 1 1 63 30,3 2,8 84 0,125 4111020 75 mm 1 1 75 36,3 3,3 100 0,208 4111022 90 mm 1 1 90 36,3 3,3 120 0,332 4111024 110 mm 1 1 110 41 4 147 0,592 4111026 125 mm 1 1 125 46 6 167 0,809 s di d 11010 Art.-No.=article number, PU = Packing unit, d=Diameter (mm), s=wall thickness (mm), di=internal diameter (mm), f=female thread, m=male thread 14 FiTTinGS aquatherm red pipe RedUceR / b1 SdR Art.-no.dimen- sion PU m/pc Price m/pc Price eURo d d1 l z d weight 7,4 socket welding 4111112 25/20 mm 10 1 25 20 38,5 24 29,5 0,013 4111116 32/25 mm 5 1 32 25 38 22 34 0,021 4111122 40/32 mm 5 1 40 32 50 32 43 0,035 4111124 50/20 mm 5 1 50 20 55 40,5 29,5 0,044 4111128 50/32 mm 5 1 50 32 54 36 43 0,052 4111130 50/40 mm 5 1 50 40 53 32,5 52 0,057 4111131 63/20 mm 1 1 63 20 65 50,5 29,5 0,074 4111138 63/50 mm 1 1 63 50 63,5 40 68 0,116 4111140 75/50 mm 1 1 75 50 63 39,5 68 0,109 4111142 75/63 mm 1 1 75 63 71 43,5 84 0,131 4111152 90/63 mm 1 1 90 63 78 50,5 84 0,244 4111153 90/75 mm 1 1 90 75 81,5 51,5 100 0,288 4111155 110/63 mm 1 1 110 63 86 58,5 84 0,349 4111159 110/90 mm 1 1 110 90 99 66 120 0,531 4111163 125/90 mm 1 1 125 90 99 66 120 0,531 4111165 125/110 mm 1 1 125 110 112 75 147 0,819 11 butt welding 4111175 160/110 mm 1 1 160 110 90 53 147 1,024 4111177 160/125 mm 1 1 160 125 90 50 167 0,940 aquatherm red pipe RedUcinG SockeT / b1 female/female Art.-no.dimension PU m/pc Price m/pc Price eURo d d1 L l z d d1 weight 4111238 63/50 mm 1 1 63 50 56 30 2,5 84 68 0,117 4111242 75/63 mm 1 1 75 63 62,5 32,5 2,5 100 84 0,181 4111253 90/75 mm 1 1 90 75 69 36 3 120 100 0,297 11134 11238 socket side PRodUcTS 15 12308 aquatherm red pipe eLbow 90°/ b1 SdR Art.-no.dimension PU m/pc Price m/pc Price eURo d z l d weight 7,4 socket welding 4112108 20 mm 10 1 20 11 25,5 29,5 0,018 4112110 25 mm 10 1 25 13,5 29,5 34 0,025 4112112 32 mm 5 1 32 17 35 43 0,041 4112114 40 mm 5 1 40 21 41,5 52 0,071 4112116 50 mm 5 1 50 26 49,5 68 0,161 4112118 63 mm 1 1 63 32,5 60 84 0,277 4112120 75 mm 1 1 75 38,5 68,5 100 0,447 4112122 90 mm 1 1 90 46 79 120 0,802 4112124 110 mm 1 1 110 56 93 147 1,412 4112126 125 mm 1 1 125 76,5 116,5 167 1,964 11 butt welding 4112131 160 mm 1 1 160 FiTTinGS aquatherm red pipe eLbow 90°/ b1 female/male Art.-no.dimen- sion PU m/pc Price m/pc Price eURo d z l d l1 z1 weight 4112308 20 mm f/m 10 1 20 11 25,5 29,5 25,5 14,75 0,018 4112310 25 mm f/m 10 1 25 13,5 29,5 34 29,5 17 0,025 4112312 32 mm f/m 5 1 32 17 35 43 39 21,5 0,041 4112314 40 mm f/m 5 1 40 21 41,5 52 45,5 26 0,071 12106 PRodUcTS 4112108-4112126 4112131 16 aquatherm red pipe eLbow 45° / b1 SdR Art.-no.dimension PU m/pc Price m/pc Price eURo d z l d weight 7,4 socket welding 4112508 20 mm 10 1 20 5 19,5 29,5 0,014 4112510 25 mm 10 1 25 6 22 34 0,019 4112512 32 mm 5 1 32 7,5 25,5 43 0,035 4112514 40 mm 5 1 40 9,5 30 52 0,054 4112516 50 mm 5 1 50 11,5 35 68 0,115 4112518 63 mm 1 1 63 14 41,5 84 0,221 4112520 75 mm 1 1 75 16,5 46,5 100 0,343 4112522 90 mm 1 1 90 19,5 52,5 120 0,558 4112524 110 mm 1 1 110 23,5 60,5 147 0,995 4112526 125 mm 1 1 125 27 67 167 1,278 11 butt welding 4112531 160 mm 1 1 160 95 1,380 Advice: Special elbows in diverse degree sizes on request aquatherm red pipe Tee / b1 SdR Art.-no.dimen- sion PU m/pc Price m/pc Price eURo d d l z l1 z1 weight 7,4 socket welding 4113108 20 mm 10 1 20 29,5 25,5 11 25,5 11 0,024 4113110 25 mm 10 1 25 34 31 15 31 15 0,033 4113112 32 mm 5 1 32 43 35 17 35 17 0,061 4113114 40 mm 5 1 40 52 40,5 20 40,5 20 0,089 4113116 50 mm 5 1 50 68 49,5 26 49,5 26 0,205 4113118 63 mm 1 1 63 84 60 32,5 60 32,5 0,368 4113120 75 mm 1 1 75 100 68,5 38,5 68,5 38,5 0,556 4113122 90 mm 1 1 90 120 79 46 79 46 0,968 4113124 110 mm 1 1 110 147 93 56 93 56 1,718 4113126 125 mm 1 1 125 167 116,5 76,5 116,5 76,5 2,671 11 butt welding 4113131 160 mm 1 1 160 145 2,791 12506 13108 Status Änderungen Datum Name Datum Name Gezeichnet Kontrolliert Norm Position MengeMaßstab Material : Allgemeintol.DIN ISO 2768-c Oberflächeaquatherm extrusions & spritzgießtechnik Freigabe : 01.04.200801.04.2008 T-Stück PP 1Blatt:Art.-Nr: Stk. d20 - d125 A.KellerD.Tusche 01.04.08 4113108 - 4113126WD l1z ld z1 FiTTinGS PRodUcTS 4112508-4112526 4112531 4113108-4113126 4113131 17 aquatherm red pipe eLbow 45° / b1 female/male Art.-no.dimen- sion PU m/pc Price m/pc Price eURo d z l d l1 z1 weight 4112708 20 mm f/m 10 1 20 5 19,5 29,5 19,5 8,75 0,014 4112710 25 mm f/m 10 1 25 6 22 34 22 8,5 0,018 4112712 32 mm f/m 5 1 32 7,5 25,5 43 28,5 11,5 0,036 4112714 40 mm f/m 5 1 40 9,5 30 52 30,5 13,5 0,057 aquatherm red pipe RedUcinG Tee / b1 SdR Art.-no.dimension PU m/pc Price m/pc Price eURo d l z d d1 l1 z1 d1 d2 l2 z2 weight 7,4 socket welding 4113511 20 x 25 x 20 mm 10 1 20 31 16,5 34 25 30,5 14,5 34 20 31 16,5 0,041 4113520 25 x 20 x 20 mm 10 1 25 31 15 34 20 30,5 16 34 20 31 16,5 0,040 4113522 25 x 20 x 25 mm 10 1 25 31 15 34 20 30,5 16 34 25 31 15 0,036 4113532 32 x 20 x 20 mm 5 1 32 36,75 18,75 43 20 37 22,5 43 20 36,75 22,25 0,082 4113534 32 x 20 x 32 mm 5 1 32 35 17 43 20 31 16,5 29,5 32 35 17 0,053 4113540 32 x 25 x 32 mm 5 1 32 35 17 43 25 32 16 34 32 35 17 0,064 4113544 40 x 25 x 40 mm 5 1 40 41,5 21 52 25 36 20 34 40 41,5 21 0,089 4113546 40 x 32 x 40 mm 5 1 40 42 21,5 52 32 40,5 22,5 52 40 42 21,5 0,106 4113550 50 x 32 x 50 mm 5 1 50 49,5 26 68 32 44,5 26,5 43 50 49,5 26 0,184 4113551 50 x 40 x 50 mm 5 1 50 49,5 26 68 40 49,5 29 68 50 49,5 26 0,224 4113556 63 x 32 x 63 mm 1 1 63 60 32,5 84 32 53,5 35,5 52 63 60 32,5 0,344 4113558 63 x 40 x 63 mm 1 1 63 60 32,5 84 40 53,5 33 52 63 60 32,5 0,333 4113560 63 x 50 x 63 mm 1 1 63 60 32,5 84 50 60 36,5 84 63 60 32,5 0,400 4113566 75 x 40 x 75 mm 1 1 75 68,5 38,5 100 40 59 38,5 52 75 68,5 38,5 0,537 4113568 75 x 50 x 75 mm 1 1 75 68,5 38,5 100 50 66 42,5 84 75 68,5 38,5 0,523 4113570 75 x 63 x 75 mm 1 1 75 68,5 38,5 100 63 66 38,5 84 75 68,5 38,5 0,550 4113578 90 x 40 x 90 mm 1 1 90 79 46 120 40 65 44,5 52 90 79 46 0,892 4113580 90 x 50 x 90 mm 1 1 90 79 46 120 50 75 51,5 84 90 79 46 1,006 4113582 90 x 63 x 90 mm 1 1 90 79 46 120 63 75 47,5 84 90 79 46 0,915 4113584 90 x 75 x 90 mm 1 1 90 79 46 120 75 81 51 120 90 79 46 1,040 4113586 110 x 63 x 110 mm 1 1 110 93 56 147 63 87,5 60 100 110 93 56 1,673 4113588 110 x 75 x 110 mm 1 1 110 93 56 147 75 87,5 57,5 100 110 93 56 1,627 4113590 110 x 90 x 110 mm 1 1 110 93 56 147 90 89 56 120 110 93 56 1,647 4113592 125 x 75 x 125 mm 1 1 125 116,5 76,5 167 75 106,5 76,5 100 125 116,5 76,5 1,626 4113594 125 x 90 x 125 mm 1 1 125 116,5 76,5 167 90 109,5 76,5 120 125 116,5 76,5 1,647 4113596 125 x 110 x 125 mm 1 1 125 116,5 76,5 167 110 113,5 76,5 147 125 116,5 76,5 2,628 11 butt welding 4113601 160 x 75 x 160 mm 1 1 160 230 92 100 75 160 3,140 4113603 160 x 90 x 160 mm 1 1 160 230 92 120 90 160 3,180 12708 13550 Status Änderungen DatumNameDatum NameGezeichne tKontrol lie rtNorm Position MengeMaßstabMateria l :Allgemeintol .DIN ISO 2768-cOberflächeaquathermextrusions & spritzgießtechnikFreigabe :01.04.200801.04.2008D.Tusche01.04.2008Red.-T-Stück4113511 - 4113596WPP1Blatt:Art.-Nr:Stk.A.KellerD.TuschedDd1 D1d2z2 z l l1z1l2D FiTTinGS PRodUcTS 4113511-4113596 4113601-4113603 18 FiTTinGS aquatherm red pipe cRoSS / b1 Art.-no.dimension PU m/pc Price m/pc Price eURo d z l d weight 4113712 32 mm 5 1 32 17 35 43 0,067 4113714 40 mm 5 1 40 21 41,5 52 0,105 aquatherm red pipe end cAP / b1 SdR Art.-no.dimension PU m/pc Price m/pc Price eURo d l z d weight 7,4 socket welding 4114108 20 mm 10 1 20 24 9,5 29,5 0,011 4114110 25 mm 10 1 25 24 8 34 0,009 4114112 32 mm 5 1 32 31,5 13,5 43 0,023 4114114 40 mm 5 1 40 38 17,5 52 0,042 4114116 50 mm 5 1 50 44,5 21 68 0,079 4114118 63 mm 1 1 63 52 24,5 84 0,145 4114120 75 mm 1 1 75 58,5 28,5 100 0,240 4114122 90 mm 1 1 90 67,5 34,5 120 0,379 4114124 110 mm 1 1 110 65 28 147 0,617 4114126 125 mm 1 1 125 70 30 167 0,857 11 butt welding 4114131 160 mm 1 1 131 70 14,6 160 0,795 aquatherm red pipe RedUcinG Tee / b1 Art.-no.dimen- sion PU m/pc Price m/pc Price eURo d1 z1 d1 l1 d z d l weight 4113750 50 / 32 mm 5 1 32 26,5 43 44,5 50 26 68 49,5 0,170 4113756 63 / 32 mm 1 1 32 35,5 52 53,5 63 32,5 84 60 0,323 4113758 63 / 40 mm 1 1 40 33 52 53,5 63 32,5 84 60 0,302 4113764 75 / 32 mm 1 1 32 41 52 59 75 38,5 100 68,5 0,55 4113766 75 / 40 mm 1 1 40 38,5 52 59 75 38,5 100 68,5 0,483 4113768 75 / 50 mm 1 1 50 42,50 68,00 66 75 38,50 100,00 68,50 0,509 4113776 90 / 50 mm 1 1 50 51,5 68 75 90 35,5 120 68,5 0,703 13708 14108 Status Änderungen Datum Name Datum Name Gezeichnet Kontrolliert Norm Position MengeMaßstab Material : Allgemeintol.DIN ISO 2768-c Oberflächeaquatherm extrusions & spritzgießtechnik Freigabe : 01.04.200801.04.2008 D.Tusche01.04.2008 Red.-Kreuzstück 4113750 - 4113766W PP 1Blatt:Art.-Nr: Stk. A.KellerD.Tusche d D d1D1zlz1 l1 PRodUcTS 19 FiTTinGS aquatherm red pipe bASe PART FoR SPRinkLeR oUTLeT Art.-no.PU m/St Price m/St Price eURo d d1 d l weight 4114180 for visible sprinkler 25 1 47,35 30 4 27 0,012 aquatherm red pipe bASe PART FoR SPRinkLeR oUTLeT Art.-no.PU m/St Price m/St Price eURo d d1 d l weight 4114190 for covered sprinkler 25 1 65 44 4 38 0,033 aquatherm red pipe UPPeR PART FoR SPRinkLeR oUTLeT for visible sprinkler Art.-no.dimension PU m/pc Price m/pc Price eURo d d1 d l weight 4114181 1/2"25 1 60 51,4 23,2 30 0,025 4114182 3/4"25 1 60 51,6 30,2 30 0,023 4114183 1"25 1 60 51,6 35,2 30 0,023 aquatherm red pipe UPPeR PART FoR SPRinkLeR oUTLeT for covered sprinkler Art.-no.dimension PU m/pc Price m/pc Price eURo d d1 d l weight 4114191 1/2"25 1 70 78 23,2 43 0,054 4114192 3/4"25 1 70 78 30,2 43 0,055 4114193 1"25 1 70 78 35,2 43 0,053 Status Änderungen Datum Name Datum Name Gezeichnet Kontrolliert Norm Position MengeMaßstab Material : Allgemeintol. 2768-c Oberflächeaquatherm extrusions & spritzgießtechnik Freigabe :1 A4 1:1 PA Unterteil für fire-stopSprinkleranschlußdose Art.-Nr.: 4114180W 31.05.06 Hunold31.05.06 31.05.06 Tusche D 1d lD Status Änderungen Datum Name Datum Name Gezeichnet Kontrolliert Norm Position MengeMaßstab Material : Allgemeintol. 2768-c Oberflächeaquatherm extrusions & spritzgießtechnik Freigabe :1 A4 1:1 PA Unterteil für fire-stopSprinkleranschlußdose Art.-Nr.: 4114180W 31.05.06 Hunold31.05.06 31.05.06 Tusche D 1d lD Status Änderungen Datum Name Datum Name Gezeichnet Kontrolliert Norm Position MengeMaßstab Material : Allgemeintol.DIN ISO 2768-c Oberflächeaquatherm extrusions & spritzgießtechnik Freigabe : 22.09.08 22.09.08 Unterteil groß für fire-stop 1:1 PA Blatt:Art.-Nr: Stk. Sprinkleranschlußdose Hunold Tusche 22.09.08 4114190WdD1 D lStatus Änderungen Datum Name Datum Name Gezeichnet Kontrolliert Norm Position MengeMaßstab Material : Allgemeintol.DIN ISO 2768-c Oberflächeaquatherm extrusions & spritzgießtechnik Freigabe : 22.09.08 22.09.08 Unterteil groß für fire-stop 1:1 PA Blatt:Art.-Nr: Stk. Sprinkleranschlußdose Hunold Tusche 22.09.08 4114190WdD1 D lStatus Änderungen Datum Name Datum Name Gezeichnet Kontrolliert Norm Position MengeMaßstab Material : Allgemeintol.DIN ISO 2768-c Oberflächeaquatherm extrusions & spritzgießtechnik Freigabe : 22.09.08 22.09.08 Unterteil groß für fire-stop 1:1 PA Blatt:Art.-Nr: Stk. Sprinkleranschlußdose Hunold Tusche 22.09.08 4114190WdD1 D lA-A ( 1 : 1 ) Status Änderungen Datum Name Datum Name Gezeichnet Kontrolliert Norm Position MengeMaßstab Material : Allgemeintol. 2768-c Oberflächeaquatherm extrusions & spritzgießtechnik Freigabe :1A4 AA 1:1 PA Oberteil für fire-stop Sprinkleranschlußdose 1/2"-1" Art.-Nr.: 4114181-83W 31.05.06 Hunold31.05.06 31.05.06 Tusche 1 d1 lD A-A Status Änderungen Datum Name Datum Name Gezeichnet Kontrolliert Norm Position MengeMaßstab Material : Allgemeintol.DIN ISO 2768-c Oberflächeaquatherm extrusions & spritzgießtechnik Freigabe : 22.09.0822.09.08 Oberteil groß für fire-stop 1:1 PA Blatt:Art.-Nr: Stk. Sprinkleranschlußdose 1/2" - 1" HunoldTusche 22.09.08 4114191 - 4114193W AA D1 ld D A-A Status Änderungen Datum Name Datum Name Gezeichnet Kontrolliert Norm Position MengeMaßstab Material : Allgemeintol.DIN ISO 2768-c Oberflächeaquatherm extrusions & spritzgießtechnik Freigabe : 22.09.08 22.09.08 Oberteil groß für fire-stop 1:1 PA Blatt:Art.-Nr: Stk. Sprinkleranschlußdose 1/2" - 1" Hunold Tusche 22.09.08 4114191 - 4114193W AA D1 ld D A-A Status Änderungen Datum Name Datum NameGezeichnet Kontrolliert Norm Position MengeMaßstab Material :Allgemeintol.DIN ISO 2768-c Oberflächeaquatherm extrusions & spritzgießtechnik Freigabe : 22.09.08 22.09.08 Oberteil groß für fire-stop 1:1 PA Blatt:Art.-Nr: Stk. Sprinkleranschlußdose 1/2" - 1" Hunold Tusche 22.09.08 4114191 - 4114193W AA D1 ldD A-A ( 2 : 1 ) Status Änderungen Datum Name Datum Name Gezeichnet Kontrolliert Norm Position MengeMaßstab Material : Allgemeintol. 2768-m Oberflächeaquatherm extrusions & spritzgießtechnik Freigabe :1 A4 AA 2:1 CuZn39Pb3 fire-stop Stopfenfür Sprinkleranschluß Art.-Nr.: 4114185-87W 04.10.12 Vollmer04.10.12 04.10.12 Tusche R lS W zA-A ( 2 : 1 ) Status Änderungen Datum Name Datum Name Gezeichnet Kontrolliert Norm Position MengeMaßstab Material : Allgemeintol. 2768-m Oberflächeaquatherm extrusions & spritzgießtechnik Freigabe :1A4 AA 2:1 CuZn39Pb3 fire-stop Stopfenfür Sprinkleranschluß Art.-Nr.: 4114185-87W 04.10.12 Vollmer04.10.12 04.10.12 Tusche R lS W zaquatherm red pipe PLUG FoR SPRinkLeR oUTLeT Art.-no.dimen- sion PU m/pc Price m/pc Price eURo R d l z Sw weight 4114185 1/2"25 1 1/2"23 21,5 11 15 0,045 4114186 3/4"25 1 3/4"30 23 12,5 17 0,061 4114187 1"25 1 1"35 24 13 17 0,079 A-A ( 1 : 1 ) Status Änderungen Datum Name Datum Name Gezeichnet Kontrolliert Norm Position MengeMaßstab Material : Allgemeintol. 2768-c Oberflächeaquatherm extrusions & spritzgießtechnik Freigabe :1 A4 AA 1:1 PA Oberteil für fire-stop Sprinkleranschlußdose 1/2"-1" Art.-Nr.: 4114181-83W 31.05.06 Hunold31.05.06 31.05.06 Tusche  d lD1 PRodUcTS 20 FiTTinGS aquatherm red pipe TeMPoRARy PLUG FoR PLASTeR woRkS made of PE foam Art.-no.dimension PU m/pc Price m/pc Price eURo d d l weight 4114178 for 4114181, -82, -83 50 1 20 75,5 42 0,007 4114179 for 4114191, -92, -93 50 1 20 60 32 0,006 aquatherm red pipe SPRinkLeR oUTLeT Art.-no.dimension PU m/pc Price m/pc Price eURo d d l weight 4114200 1 1/4"10 1 100,10 44,10 6,50 0,03 4114201 1 1/2"10 1 111,10 50,10 6,50 0,036 4114202 2"10 1 126,10 61,10 6,50 0,045 aquatherm red pipe PLUG FoR PReSSURe TeST Art.-no.dimension PU m/pc Price m/pc Price eURo d G1 G2 z l Sw weight 4114212 thread 1/2"10 1 35 1/2"1/8"9 21,5 27 0,064 4114213 thread 3/4"10 1 35 3/4"1/8"9 21,5 27 0,085 4114214 thread 1"10 1 40 1"1/8"8,5 21,5 27 0,12 aquatherm red pipe coUPLinG PLUG 1/2“ 4114220 1/2" for Art-. No. 4114212, -13, -14 1 1 aquatherm red pipe PLUG FoR SPRinkLeR oUTLeT Art.-no.dimension PU m/pc Price m/pc Price eURo 4114206 Plug for sprinkler outlet 1 1/4“10 1 4114207 Plug for sprinkler outlet 1 1/2“10 1 4114208 Plug for sprinkler outlet 2“10 1 A-A Status Änderungen Datum Name Datum Name Gezeichnet Kontrolliert Norm Position MengeMaßstab Material : Allgemeintol.DIN ISO 2768-c Oberflächeaquatherm extrusions & spritzgießtechnik Freigabe : 07.01.10 07.01.10 PE- Schaumronde 1:1 Blatt:Art.-Nr: Stk. Sprinkleranschlußdose Hunold 4114178-79W AAld D A-A Status Änderungen Datum Name Datum Name Gezeichnet Kontrolliert Norm Position MengeMaßstab Material : Allgemeintol.DIN ISO 2768-c Oberflächeaquatherm extrusions & spritzgießtechnik Freigabe : 07.01.10 07.01.10 PE- Schaumronde 1:1 Blatt:Art.-Nr: Stk. Sprinkleranschlußdose Hunold 4114178-79W AAldD A-A Status Änderungen Datum Name Datum Name Gezeichnet Kontrolliert Norm Position MengeMaßstab Material : Allgemeintol.DIN ISO 2768-c Oberflächeaquatherm extrusions & spritzgießtechnik Freigabe : 30.08.2010 30.08.2010 firestop Anschlußdose 1:1 Blatt:Art.-Nr: Stk. Vollmer Tusche 30.08.2010 4114200-4114202W AA D d lA-A Status Änderungen Datum Name Datum Name Gezeichnet Kontrolliert Norm Position MengeMaßstab Material : Allgemeintol.DIN ISO 2768-c Oberflächeaquatherm extrusions & spritzgießtechnik Freigabe : 30.08.2010 30.08.2010 firestop Anschlußdose 1:1 Blatt:Art.-Nr: Stk. Vollmer Tusche 30.08.2010 4114200-4114202W AA D d l41142204114220 Status Änderungen Datum Name Datum Name Gezeichnet Kontrolliert Norm Position MengeMaßstab Material : Allgemeintol.DIN ISO 2768-m Oberflächeaquatherm extrusions & spritzgießtechnik Freigabe : 06.11.2012 06.11.2012 firestop Abdrückstopfen 2:1 CuZn39Pb3 Blatt:Art.-Nr: Stk. für Sprinkleranschlußdose Vollmer Tusche 06.11.2012 4114212-14W SWD G1 lzG2 Status Änderungen Datum Name Datum Name Gezeichnet Kontrolliert Norm Position MengeMaßstab Material : Allgemeintol.DIN ISO 2768-m Oberflächeaquatherm extrusions & spritzgießtechnik Freigabe : 06.11.2012 06.11.2012 firestop Abdrückstopfen 2:1 CuZn39Pb3 Blatt:Art.-Nr: Stk. für Sprinkleranschlußdose Vollmer Tusche 06.11.2012 4114212-14W SWD G1 lzG2 PRodUcTS 21 FiTTinGS FiTTinGS aquatherm red pipe weLd-in SAddLe SdR Art.-no.dimension PU m/pc Price m/pc Price eURo d d1 d2 l z d weight 7,4 socket welding 4115156 40/20 mm 5 1 40 20 25 27 32,5 29,5 0,015 4115158 40/25 mm 5 1 40 25 25 28,5 32,5 34 0,017 4115160 50/20 mm 5 1 50 20 25 27,5 38 29,5 0,018 4115162 50/25 mm 5 1 50 25 25 28,5 37,5 34 0,019 4115164 63/20 mm 5 1 63 20 25 27,5 44,5 29,5 0,018 4115166 63/25 mm 5 1 63 25 25 28,5 44 34 0,019 4115168 63/32 mm 5 1 63 32 32 30 43,5 43 0,026 4115170 75/20 mm 5 1 75 20 25 27,5 50,5 29,5 0,018 4115172 75/25 mm 5 1 75 25 25 28,5 50 34 0,019 4115174 75/32 mm 5 1 75 32 32 30 49,5 43 0,027 4115175 75/40 mm 5 1 75 40 40 34 51 52 0,048 4115176 90/20 mm 5 1 90 20 25 27,5 58 29,5 0,019 4115178 90/25 mm 5 1 90 25 25 28,5 57,5 34 0,019 4115180 90/32 mm 5 1 90 32 32 30 57 43 0,027 4115181 90/40 mm 5 1 90 40 40 34 58,5 52 0,048 4115182 110/20 mm 5 1 110 20 25 27,5 68 29,5 0,019 4115184 110/25 mm 5 1 110 25 25 28,5 67,5 34 0,020 4115186 110/32 mm 5 1 110 32 32 30 67 43 0,028 4115188 110/40 mm 5 1 110 40 40 34 68,5 52 0,049 4115189 110/50 mm 5 1 110 50 50 34 65,5 68 0,029 4115190 125/20 mm 5 1 125 20 25 27,5 75,5 29,5 0,019 4115192 125/25 mm 5 1 125 25 25 28,5 75 34 0,021 4115194 125/32 mm 5 1 125 32 32 30 74,5 43 0,030 4115196 125/40 mm 5 1 125 40 40 34 76 52 0,051 4115197 125/50 mm 5 1 125 50 50 34 73 68 0,029 4115198 125/63 mm 5 1 125 63 63 38 73 84 0,029 11 butt welding 4115218 160/75 mm 5 1 160 75 75 42 92 100 0,229 4115220 160/90 mm 5 1 160 90 90 45 92 120 0,338 With weld-on surface and weld-in socket to be fused with the inner wall of the pipe. The required tools for the fusion of aquatherm red pipe-weld-in saddles are listed on page 32: aquatherm red pipe-weld-in saddle tools Art.-No. 50614 - 50658 aquatherm-drill Art.-No. 50940 - 50952 PRodUcTS 22 FiTTinGS aquatherm red pipe STeeL FLAnGe Art.-no.dimension no. of holes Hole circle PU m/pc Price m/pc Price eURo d d d1 d1 l z weight 4115712 32 mm 4 85 mm 1 1 42 116 85 14 15,5 4 0,458 4115714 40 mm 4 100 mm 1 1 51 141 100 18 17,5 4 0,708 4115716 50 mm 4 110 mm 1 1 62 151 110 18 17,5 4 0,778 4115718 63 mm 4 125 mm 1 1 78 166 125 18 19 4 0,910 4115720 75 mm 4 145 mm 1 1 92 186 145 18 19 4 1,160 4115722 90 mm 8 160 mm 1 1 110 201 160 18 21 8 1,390 4115724 110 mm 8 180 mm 1 1 133 221 180 18 22 8 1,492 4115726 125 mm 8 210 mm 1 1 167 251 210 18 26 8 1,492 4115730 160 mm 8 240 mm 1 1 178 286 240 22 27 8 3,628 A-A Status Änderungen Datum Name Datum Name Gezeichnet Kontrolliert Norm Position MengeMaßstab Material :Allgemeintol.DIN ISO 2768-c Oberflächeaquatherm extrusions & spritzgießtechnik Freigabe : 01.04.200801.04.2008 Flansch St 1Blatt:Art.-Nr: Stk. d32 - d125 U.HunoldD.Tusche 01.04.08 4115712 - 4115726W A A dDl zd1D1A-A Status Änderungen Datum Name Datum Name Gezeichnet Kontrolliert Norm Position MengeMaßstab Material : Allgemeintol.DIN ISO 2768-c Oberflächeaquatherm extrusions & spritzgießtechnik Freigabe : 01.04.2008 01.04.2008 Flansch St 1Blatt:Art.-Nr: Stk. d32 - d125 U.Hunold D.Tusche 01.04.08 4115712 - 4115726W A A dDl zd1D1aquatherm red pipe weLdAbLe FLAnGe AdAPTeR / b1 with joint ring SdR Art.-no.dimension PU m/pc Price m/pc Price eURo d l z d d1 l1 z1 weight 7,4 socket welding 4115512 32 mm 1 1 32 35 17 41 68 11 3 0,031 4115514 40 mm 1 1 40 36,5 16 50 78 12 3 0,044 4115516 50 mm 1 1 50 40,5 17 61 88 13 3 0,061 4115518 63 mm 1 1 63 44,5 17 76 102 15 3 0,100 4115520 75 mm 1 1 75 47 17 90 122 17 3 0,143 4115522 90 mm 1 1 90 50 17 108 138 17 3 0,252 4115524 110 mm 1 1 110 55,5 18,5 131 158 18,5 3 0,327 4115527 125 mm 1 1 125 63 23 165 188 20 3 1,310 11 butt welding 4115531 160 mm 1 1 160 25 93 175 14,6 53 0,955 15512 PRodUcTS 23 FiTTinGS TRAnSiTion Piece aquatherm red pipe bAck PLATe eLbow / b1 Art.-no.dimension PU m/pc Price m/pc Price eURo d l z d l1 z1 d1 L c R d1 weight 4120108 20 mm x 1/2" 10 1 20 31 16,5 29,5 31,5 15,5 37 51 20 1/2"7 0,085 4120112 25 mm x 3/4" 10 1 25 37 21 34 37 24 44 54 25 3/4"7 0,111 aquatherm red pipe coUPLinG ScRew / b1 Art.-no.dimension PU m/pc Price m/pc Price eURo d l z d Sw1 Sw2 weight 4115812 32 mm 1 1 32 36,5 18,5 41 64 50 0,498 4115814 40 mm 1 1 40 38 17,5 50 80 60 0,842 4115816 50 mm 1 1 50 41 17,5 61 86 70 0,945 4115818 63 mm 1 1 63 45 17,5 76 108 90 1,541 4115820 75 mm 1 1 75 47,5 17,5 90 128 104 2,040 Incl. 2 flange adapters with gasket PRodUcTS 24 TRAnSiTion Piece aquatherm red pipe TRAnSiTion Piece / b1 with hexagon (*suitable for the connection to sprinkler outlets) Art.-no.dimension PU m/pc Price m/pc Price eURo d l z d L R Sw weight 4121108 20 mm x 1/2“ f 10 1 20 34,5 20 37,5 50,5 1/2"24 0,087 4121110 20 mm x 3/4“ f 10 1 20 29 14,5 43,5 50 3/4"31 0,113 4121111 25 mm x 1/2“ f 10 1 25 36 20 37,5 52 1/2"24 0,087 4121112 25 mm x 3/4“ f 10 1 25 29 13 43,5 50 3/4"31 0,111 4121113 32 mm x 3/4“ f 5 1 32 32 14 43,5 53 3/4"31 0,114 4121114*32 mm x 1“ f 5 1 32 37,5 19,5 60 59,5 1"39 0,239 4121115*40 mm x 1“ f 5 1 40 40 19,5 60 62 1"39 0,246 4121116 40 mm x 1 1/4“ f 5 1 40 42,5 19,5 74 63 1 1/4"50 0,383 4121117 50 mm x 1 1/4“ f 5 1 50 42,5 19,5 74 66 1 1/4"50 0,401 4121118 50 mm x 1 1/2“ f 5 1 50 45 21,5 85,5 67 1 1/2"55 0,445 4121119 63 mm x 1 1/2“ f 1 1 63 51,5 24 84 73,5 1 1/2"55 0,468 4121120 63 mm x 2“ f 1 1 63 50 22,5 101 76 2"67 0,650 4121122 75 mm x 2“ f 1 1 75 51 21 100 77 2"67 0,671 4121153 32 mm x 1/2“ f 5 1 32 37 19 43 53 1/2"24 0,091 4121154 40 mm x 1/2“ f 5 1 40 38 17,5 52 55,5 1/2"24 0,101 aquatherm red pipe TRAnSiTion Piece / b1 for the connection to sprinkler outlets round Art.-no.dimension PU m/pc Price m/pc Price eURo d l z d L R weight 4121008 20 mm x 1/2“ f 10 1 20 27,5 13 37,5 40,5 1/2"0,070 4121011 25 mm x 1/2“ f 10 1 25 29 13 37,5 42 1/2"0,071 4121012 25 mm x 3/4“ f 10 1 25 27,5 11,5 43,5 40,5 3/4"0,086 4121013 32 mm x 3/4“ f 5 1 32 30,5 12,5 43,5 43,5 3/4" 4121014 32 mm x 1/2“ f 5 1 32 30 12 37,5 43 1/2"0,081 4121016 40 mm x 1/2“ f 5 1 40 32,5 12 52 45,5 1/2"0,087 4121017 40 mm x 3/4“ f 5 1 40 33 12,5 52 46 3/4'' 21108 21008 Status Änderungen Datum Name Datum Name Gezeichnet Kontrolliert Norm Position MengeMaßstab Material : Allgemeintol.DIN ISO 2768-c Oberflächeaquatherm extrusions & spritzgießtechnik Freigabe : 01.04.2008 01.04.2008 Übergangsstück rund PP/MS 1Blatt:Art.-Nr: Stk. U.Hunold D.Tusche 31.10.2011 4121008-4121017W d lR D zLPRodUcTS 25 TRAnSiTion Piece aquatherm red pipe TRAnSiTion eLbow / b1 Art.-no.dimension PU m/pc Price m/pc Price eURo d l z d l1 z1 d1 R weight 4123008 20 mm x 3/4“ f 10 1 20 37 22,5 34 37 24 44 3/4"0,108 4123010 20 mm x 1/2“ f 10 1 20 31,5 17 29,5 31,5 18,5 37 1/2"0,081 4123012 25 mm x 3/4“ f 10 1 25 37 21 34 37 24 44 3/4"0,106 4123014 25 mm x 1/2“ f 10 1 25 34 18 34 37 24 37 1/2"0,087 4123015 32 mm x 1/2“ f 10 1 32 35 17 43 37 24 37 1/2"0,096 4123016 32 mm x 3/4“ f 5 1 32 27,5 9,5 43 51 38 44 3/4"0,110 4123018 32 mm x 1“ f 5 1 32 34 16 43 66,5 44,5 60,5 1"0,260 4123020 40 mm x 1/2“ f 5 1 40 41 20,5 52 39 26 37 1/2"0,127 4123022 40 mm x 1“ f 5 1 40 41,5 21 52 56 34 60 1"0,274 aquatherm red pipe TRAnSiTion Piece / b1 with hexagon Art.-no.dimension PU m/pc Price m/pc Price eURo d l z d R Sw weight 4121308 20 mm x 1/2“ m 10 1 20 66,5 52 38,5 1/2"22 0,118 4121310 20 mm x 3/4“ m 10 1 20 67,5 53 38,5 3/4"24 0,129 4121311 25 mm x 1/2“ m 10 1 25 68 52 38,5 1/2"21 0,109 4121312 25 mm x 3/4“ m 10 1 25 67,5 51,5 38,5 3/4"24 0,128 4121313 32 mm x 3/4“ m 5 1 32 70 52 43 3/4"24 0,117 4121314 32 mm x 1“ m 5 1 32 78,5 60,5 53 1"30 0,244 4121316 32 mm x 1 1/4“ m 5 1 32 81 63 68 1 1/4"41 0,357 4121317 40 mm x 1“ m 5 1 40 81 60,5 52 1"30 0,250 4121318 40 mm x 1 1/4“ m 5 1 40 84,5 64 68 1 1/4"41 0,364 4121319 50 mm x 1 1/4“ m 5 1 50 85,5 62 68 1 1/4"41 0,391 4121320 50 mm x 1 1/2“ m 5 1 50 88,5 65 74 1 1/2"46 0,480 4121321 63 mm x 1 1/2“ m 1 1 63 99 71,5 72,5 1 1/2"46 0,523 4121322 63 mm x 2“ m 1 1 63 102,5 75 84 2"50 0,705 4121323 75 mm x 2“ m 1 1 75 102 72 84 2"50 0,753 4121324 75 mm x 2 1/2“ m 1 1 75 105 75 100 2 1/2"65 1,024 4121325 90 mm x 3“ m 1 1 90 121 88 120 3"83 1,530 4121327 110 mm x 4“ m 1 1 110 148 111 147 4"105 2,816 23008 21308 PRodUcTS 26 TRAnSiTion Piece aquatherm red pipe LooSe nUT AdAPTeR / b1 Length: 100 mm threaded, with gasket Art.-no.dimension PU m/pc Price m/pc Price eURo d l k R Sw weight 4126708 20 mm x nut thread 1“1 1 20 100 65 1"36 0,083 4126710 25 mm x nut thread 1 1/4“1 1 25 100 62 1 1/4"46 0,117 4126712 32 mm x nut thread 1 1/2“1 1 32 100 58 1 1/2"52 0,160 4126714 40 mm x nut thread 2“1 1 40 100 53 2"64 0,256 4126716 50 mm x nut thread 2 1/4“1 1 50 100 49 2 1/4"72 0,436 4126717 50 mm x nut thread 2 1/2“1 1 50 100 44 2 1/2"80 0,457 4126718 63 mm x nut thread 2 3/4“1 1 63 100 43 2 3/4"89 0,541 4126720 75 mm x nut thread 3 1/2“1 1 75 100 34 3 1/2"110 0,918 4126722 90 mm x nut thread 4“1 1 90 100 26 4"120 1,238 aquatherm red pipe THReAded bRAncH Tee / b1 Art.-no.dimension PU m/pc Price m/pc Price eURo d l z d l1 z1 d1 R Sw weight 4125006 20 x 1/2“ f x 20 mm 10 1 20 31,5 17 29,5 37 24 37 1/2"-0,088 4125008 20 x 3/4“ f x 20 mm 10 1 20 37 22,5 34 38 25 44 3/4"-0,120 4125010 25 x 1/2“ f x 25 mm 10 1 25 34 18 34 38 25 37 1/2"-0,093 4125012 25 x 3/4“ f x 25 mm 10 1 25 37 21 34 38 25 44 3/4"-0,116 4125013 32 x 1/2“ f x 32 mm 5 1 32 35,5 17,5 43 36 23 37 1/2"-0,105 4125014 32 x 3/4“ f x 32 mm 5 1 32 27,5 9,5 43 51 38 44 3/4"-0,118 4125016 32 x 1“ f x 32 mm 5 1 32 31 13,5 43 67 49 60 1"39 0,272 4125018 40 x 1/2“ f x 40 mm 5 1 40 42,5 22 52 39 26 37 1/2"-0,140 4125019 40 x 3/4“ f x 40 mm 5 1 40 40,5 20 52 40,5 27,5 52 3/4" 4125020 40 x 1“ f x 40 mm 5 1 40 41,5 21 52 56 34 60 1"42 4125022 50 x 1“ f x 50 mm 5 1 50 49,5 26 68 63,5 43,5 68 1"39 0,433 4125024 50 x 1 1/4“ f x 50 mm 5 1 50 49,5 26 68 65 45 68 1 1/4"50 0,488 25006 PRodUcTS max. shortening length 27 aquatherm red pipe FeMALe PART Union / b1 ISO-Norm Art.-no.dimension PU m/pc Price m/pc Price eURo d l z d R Sw weight 4127010 nut thread 1“ x 20 mm 10 1 20 58,5 36 38,5 1"36 0,182 4127012 nut thread 1 1/4“ x 25 mm 10 1 25 60 44 43,5 1 1/4"46 0,253 4127014 nut thread 1 1/2“ x 32 mm 5 1 32 69,5 51,5 60 1 1/2"52 0,437 4127016 nut thread 2“ x 40 mm 5 1 40 74 53,5 74 2"64 0,705 4127018 nut thread 2 1/4“ x 50 mm 5 1 50 78 54,5 84 2 1/4"72 0,919 4127020 nut thread 2 3/4“ x 63 mm 1 1 63 84 56,5 101 2 3/4"89 1,236 4127022 nut thread 3 1/2“ x 75 mm 1 1 75 91 61 100 3 1/2"110 1,832 aquatherm red pipe coUnTeRPART / b1 with welding socket and male thread for ISO-threaded joints Art -no dimension PU m/pc Price m/pc Price eURo d l z d R Sw weight 4127310 20 mm x 1“ m 10 1 20 61,5 47 38,5 1"24 0,149 4127312 25 mm x 1 1/4“ m 10 1 25 63 47 43,5 1 1/4"31 0,222 4127314 32 mm x 1 1/2“ m 5 1 32 76,5 58,5 60 1 1/2"39 0,404 4127316 40 mm x thread 2“ m 5 1 40 81 60,5 74 2"50 0,604 4127318 50 mm x thread 2 1/4“ m 5 1 50 83 59,5 84 2 1/4"55 0,665 4127320 63 mm x thread 2 3/4“ m 1 1 63 94 66,5 101 2 3/4"67 1,071 4127322 75 mm x thread 3 1/2“ m 1 1 75 100 70 100 3 1/2"67 1,442 aquatherm red pipe-metal composite fittings are manufactured from Fusiolen® PP-R FS and brass. 27010 27310 PRodUcTS 28 aquatherm red pipe weLd-in SAddLe wiTH FeMALe THReAd / b1 Art.-no.dimension PU m/pc Price m/pc Price eURo d d1 l z d R Sw weight 4128214 40/25 mm x 1/2“ f 5 1 40 25 39 43 38,5 1/2"24 0,087 4128216 50/25 mm x 1/2“ f 5 1 50 25 39 48 38,5 1/2"24 0,088 4128218 63/25 mm x 1/2“ f 5 1 63 25 39 54,5 38,5 1/2"24 0,088 4128220 75/25 mm x 1/2“ f 5 1 75 25 39 53,5 38,5 1/2"24 0,088 4128222 90/25 mm x 1/2“ f 5 1 90 25 39 68 38,5 1/2"24 0,088 4128224 110/25 mm x 1/2“ f 5 1 110 25 39 78 38,5 1/2"24 0,088 4128226 125/25 mm x 1/2“ f 5 1 125 25 39 85,5 38,5 1/2"24 0,091 4128234 40/25 mm x 3/4“ f 5 1 40 25 39 38 43,5 3/4"31 0,108 4128236 50/25 mm x 3/4“ f 5 1 50 25 39 43 43,5 3/4"31 0,111 4128238 63/25 mm x 3/4“ f 5 1 63 25 39 49,5 43,5 3/4"31 0,110 4128240 75/25 mm x 3/4“ f 5 1 75 25 39 55,5 43,5 3/4"31 0,109 4128242 90/25 mm x 3/4“ f 5 1 90 25 39 63 43,5 3/4"31 0,110 4128244 110/25 mm x 3/4“ f 5 1 110 25 39 73 43,5 3/4"31 0,111 4128246 125/25 mm x 3/4“ f 5 1 125 25 39 80,5 43,5 3/4"31 0,112 4128260*75/32 mm x 1“ f 5 1 75 32 43 58,5 60 1"39 0,231 4128262*90/32 mm x 1“ f 5 1 90 32 43 66 60 1"39 0,234 4128264*110/32 mm x 1“ f 5 1 110 32 43 76 60 1"39 0,237 4128266*125/32 mm x 1“ f 5 1 125 32 43 83,5 60 1"39 0,237 with female thread and hexagon socket, with weld-in weld-on surface and weld-in socket to be fused with the inner wall of the pipe The required tools for the fusion of aquatherm red pipe-weld-in saddles are listed on page 32: - weld-in saddle tools, Art.-No. 50614 - 50644 - aquatherm-drill, Art.-No. 50940 - 50948 * Suitable for the connection to sprinkler outlets aquatherm red pipe TRAnSiTion Piece FoR GRoove connecTion / b1 Art.-no.dimension PU m/pc Price m/pc Price eURo d l z d d1 weight 4127054 40 mm x 1“ groove connection 1 1 40 81 60,5 52 33,5 0,226 4127056 50 mm x 1 1/4“ groove connection 1 1 50 85,5 62 68 42,2 0,373 4127058 63 mm x 1 1/2“ groove connection 1 1 63 97,5 70 84 48,25 0,533 4127060 75 mm x 2“ groove connection 1 1 75 97 67 100 60,3 0,788 4127062 90 mm x 3“ groove connection 1 1 88,5 110 77 120 88,9 1,395 4127064 110 mm x 4“ groove connection 1 1 108,3 119,5 82,5 147 114,3 2,117 4127066 125 mm x 5“ groove connection 1 1 125 167 130 167 140 5,270 TRAnSiTion Piece Status Änderungen Datum Name Datum Name Gezeichnet Kontrolliert Norm Position MengeMaßstab Material :Allgemeintol.DIN ISO 2768-c Oberflächeaquatherm extrusions & spritzgießtechnik Freigabe : 15.05.2014 Einschweißsättel mit Innengewinde 1:1 PP 1Blatt:Art.-Nr: Stk. Mueller 0028214-0028247Wdd1ZR D LSW Status Änderungen Datum Name Datum Name Gezeichnet Kontrolliert Norm Position MengeMaßstab Material : Allgemeintol.DIN ISO 2768-c Oberflächeaquatherm extrusions & spritzgießtechnik Freigabe : 21.11.2007 21.11.2007 Nutanschlussübergang PP/MS 1Blatt:Art.-Nr: Stk. A.Keller D.Tusche 18.10.´11 4127054-4127066WdDz l D1a Z- Maße di und t hinzu 18.10.´11 Menzeb. PRodUcTS 29 aquatherm red pipe bALL vALve PP/MS / b1 Art.-no.dimen- sion PU m/pc Price m/pc Price eURo d l z d h l1 weight 4141308 20 mm 1 1 20 55 40,5 32 66 85 0,280 4141310 25 mm 1 1 25 55 39 41 73 85 0,371 4141312 32 mm 1 1 32 63,5 45,5 47 82 108 0,593 4141314 40 mm 1 1 40 72,5 52 58 93 108 0,950 4141316 50 mm 1 1 50 83,5 60 70,5 114 140 1,585 4141318 63 mm 1 1 63 102,5 75 87 132 140 2,552 aquatherm red pipe-metal composite fittings are manufactured from Fusiolen® PP-R FS and brass. cUTTeR & weLdinG deviceS important: Do not cut the aquatherm red pipe- pipes with customary hack saws. aquatherm red pipe- pipes can be cut with customary saws equipped with saw blades suitable for plastic. aquatherm PiPe cUTTeR Art.-no.for pipe dimensions PU m/pc Price m/pc Price eURo 50102 ø 16 - 40 mm 1 1 50105 ø 50 - 125 mm 1 1 50106 ø 110 - 160 mm 1 aquatherm PiPe cUTTeR Art.-no.for pipe dimensions PU m/pc Price m/pc Price eURo 50104 ø 16 - 40 mm 1 1 oRbiTAL ciRcULAR SAw Art.-no.for pipe dimensions PU m/pc Price m/pc Price eURo 50108 ø 160 - 355 mm 1 This orbital circular saw can be ordered directly from Rothenberger with Art.-No. 5.5620 (www.rothenberger.com). High- performance orbital circular saw for fast, precise, perfectly aligned and right-angled cutting of plastic pipes 160 - 355 mm at the building site or in the workshop. cUTTinG diSc FoR PLASTic Art.-no.dimension borehole PU m/pc Price m/pc Price eURo 50107 ø 125 mm 22,2 mm 1 50109 ø 230 mm 22,2 mm 1 Application: for each angle grinder Design: diamant galvanized cutting disc PRodUcTS 30 aquatherm weLdinG MAcHine (1400 w) Art.-no.for pipe dimensions Packing unit Price m/pc Price eURo 50147 ø 50 - 125 mm 1 1 including welding tools 20-125 mm, roll stand and wooden transport case aquatherm eLecTRic weLdinG jiG Art.-no.for pipe dimensions Packing unit Price m/pc Price eURo aquatherm aquatherm50159ø 63 - 125 mm 1 1 incl. spare battery, charging station and metal case Support: Art.-No. 50151 on request aquatherm bASe FoR ART.-no. 50159 Art.-no.dimension Packing unit Price m/pc Price eURo 50151 1 1 Price m/pc aquatherm MAnUAL weLdinG device (800 w) Art.-no.for pipe dimensions PU m/pc Price m/pc Price eURo fusiotherm aquather m50337ø 16 - 63 mm 1 1 With base and case for tools aquatherm MAnUAL weLdinG device (1400 w) Art.-no.for pipe dimensions PU m/pc Price m/pc Price eURo fusiotherm aquatherm50341ø 50 - 125 mm 1 1 With base and case for tools aquatherm weLdinG MAcHine (1400 w) LiGHT Art.-no.for pipe dimensions Packing unit Price m/pc Price eURo 50145 ø 63 - 125 mm 1 1 aquatherm-manual welding device (1400 W) and wooden transport case aquatherm MAnUAL weLdinG device (500 w) Art.-no.for pipe dimensions PU m/pc Price m/pc Price eURo fusiotherm aquathe r m50336ø 16 - 32 mm 1 1 With base and case for tools bUTT weLdinG MAcHine RoTHenbeRGeR Art.-no.for pipe dimensions PU m/pc Price m/pc Price eURo 50163 ø 160 - 250 mm 1 including wooden transport box. The butt welding machine can be obtained directly from Rothenberger (www.rothenberger.com) PRodUcTS