HomeMy WebLinkAboutF15-0050_F15-0050 cut sheets 5_1438621740.pdf1 2 3 4 52 LAyING OF AqUATHeRM Red PiPe IN THE CONCRETE concrete aquatherm red pipe outlet 11/4", 11/2" and 2" aquatherm red pipe sprinkler outlet for covered sprinkler 1/2", 3/4" and 1" aquatherm red pipe sprinkler outlet for visible sprinkler 1/2", 3/4" and 1" aquatherm red pipe to steelpipe adapter ATTenTion All upper parts of sprinkler outlet must be pulled out of the concrete with the aquatherm red pipe extraction tool (Art- No. 50290). 1 2 3 4 LAyinG in THe concReTe 53 introduction: Because precast concrete products are directly shuttered and processed at factory, there remain only some working steps at site. A slab formwork on site is not required. The rapid laying and on-site installation saves time and costs. Due to the very smooth soffit by the steel formwork table a plastering is not necessary. If an installation system is mounted on the steel formwork, this must work precisely, safely and quickly. The sprinkler outlet of the sprinkler pipe system aquatherm red pipe can be easily mounted on steel formwork. The entire component is assembled in advance by an installation company and delivered to the concrete plant. In the concrete plant, the sprinkler outlets are measured on the steel form- work and mounted. Assembly: The base part of the sprinkler outlet is fixed with a magnet (min. holding force 23 kg), or with a hot-melt adhesive (temperature 100 ° C) to the steel formwork with reinforcement and also keeps the position during vibra- tions. The length of the pipe connecting piece has to be dimensioned so that it is protected by the projecting reinforcement on the transport to the site. The pipe connecting piece is protected by a protective cap and adhesive tape, thereby preventing the penetration of concrete into the interior of the pipe during filling of the mold. description of the installation in prefabricated concrete ceiling (Filigree ceiling) Base part of sprinkler outlet Art.-No. 4114180 for visible sprinklers. Attachment by magnet. The upper part of the sprinkler outlet with pipe connection is attached to the base part of the sprinkler outlet. Base part of sprinkler outlet Art.-No. 4114190 for concealed sprinklers. Attachment with hot-melt adhesive. 1. Type of connection: visible sprinkler 2. Type of connection: concealed sprinkler LAyinG in THe concReTe LAyING OF AqUATHeRM Red PiPe IN THE CONCRETE 53 54 PRüFUnG Assembly: The mold is filled with concrete and vibrated simultaneously. After shaking the concrete surface is roughened. The component is to dry in a drying chamber. After drying, the ceiling component is transported to the site and assembled. An installation company can now connect the sprinkler connections with each other and connect them to the supply pipe. Thus, this method of prefabrication allows shorter construction periods and larger areas. This results in a cost reduction on the one hand and some more flexibility – all in all an increase of economy. LAyING OF AqUATHeRM Red PiPe IN THE CONCRETE LAyinG in THe concReTe description of the installation in prefabricated concrete ceiling (Filigree ceiling) 1 2 55 Part 2: Pressure test of pipe work installation as strength test and leak test Please refer to the information on page 60-62. Part 3: What must be considered during the concreting process? All sprinkler connections have to be locked with cable clips (picture 1) and to underpin (picture2). The pipe sections must be fixed every 1.5 to 2 m in a way (using pipe hangers or lacing cord) to avoid sagging or bowing during the concreting process. It is important, that the pipe work is completely embedded with- out any hollow spaces (cavities). The entering of the pipes during the concreting process must be avoided. The compacting of the concrete with concrete vibrators in the pipe area should be carried out carefully. Impacts, especially at low temperatures (below +5 °C) must be avoided. Open pipes and connections must be closed before the concreting. LAyING OF AqUATHeRM Red PiPe IN THE CONCRETE 1 LAyinG in THe concReTe 56 Part 4: Access to connection of the pipe work in concrete option 1: The pipe work in the concrete should be connected to the supply pipe, that the connection can be accessed in case of damage. This may accomplished as follows: Before applying the concrete on the cei- ling, a form work (casing) should be constructed around the connection (allow enough space for installation work). The connection is embedded in sand or similar fill of F90-quality in the form work. The ceiling can be filled with concrete, now. After striking the ceiling, the connection can be laid open and is now accessible. The subsequent sealing of the cavity in the ceiling can be made with elements of F90-quality. The access must be visible at all times (indicated on the drawing or by mar- king the ceiling). option 2: Before casting the connection can be packed in a Rockwool-fire protection panel Conlit 150 U (allow enough space for installation work). This panel has the following features: light, water-repellent, pressure-resistant, self-supporting rockwool panel covered with glass grid Fields of application: fire protection covering for steel construction F30–A-F180-A, Increase of fire resistance class of concrete coverings. Not flammable A2 acc. to DIN 4102, Part 1. Melting point >1000° C. After shuttering of the ceilings the fire protection panel Conlit 150 U can remain in the completed ceiling and can be adjusted to the structure of the concrete ceiling by plastering. The access shall be visible, as in option 1, at all time. drawing according to options 1 and 2 LAyING OF AqUATHeRM Red PiPe IN THE CONCRETE riser opening for inspection pipe drawing according to options 1 and 2 LAyinG in THe concReTe 57 damaged pipe work in concrete, e.g. by drilling work Damaged pipe work can be repaired by fusion welding (see aquatherm red pipe sprinkler system, Part B). The aquatherm red pipe system can also be repaired using the pipe repair stick (see aquatherm red pipe sprinkler system, Part F). Part 5: bridging of expansion joints The expansion or aquatherm red pipe-pipes depends on the temperature of the pipe material. Cold water supplies cause hardly any expansion for a normal assembly nor do normal outside temperatures. The expansion need not to be considered when laying aquatherm red pipe in the concrete. Rising pressures- and tensile stresses are not critical, as they are absorbed by the material. However, if it is necessary to bridge the expansion joints, the aquatherm red pipes must be equipped with an approx. 25 cm protection pipe at both ends of the joint. A confirmation of the responsible architect resp. structural designer must certify that no lengthwise movements in the expansion joints can be ex- pected. The coefficient of expansion of aquatherm red pipe-pipes is 0.035 mm/mK The coefficient of expansion of concrete is 0.05 – 0.12 mm/mK. Part 6: Potential equalizing The VDE 0190 Part 410 and 540 requires a potential equalizing between all kinds of earth conductors and the existing “conductible” potable and waste water supplies and heating pipes. As aquatherm red pipe is not a conductible pipe system, it cannot be used for potential equalizing and thus needs no earth wiring. The potential equalizing is made according to VDE-standard from the buil- ding parts, which have to be earth wired, directly to the potential equa- lizing rail to the planned position. The constructor or site manager must advise the client or his representative, that an approved electrician must check, if the aquatherm red pipe installation does not affect the existing electrical protection and earth wiring measurements (VOB Part C, general- technical conditions of contract ATV). Part 7: Pressurizing in the aquatherm red pipe-supply during the concre- ting process During the concreting process the pipe must be pressurized with the ad- missible operating pressure, so that a damaged point is visible at once. After the pressure test the admissible operating pressure is kept by shut off of the respective pipe. The applied measuring devices must grant a correct reading of pressure changes of 0.1 bar. The pressure measuring device shall be installed at the deepest point of the pipe system. Part 8: influence of the concrete to the applied compounds The aquatherm red pipe-pipe system contains all required compounds for a complete system installation. Mixed installation with non-system and/or non-material compounds are not required. All material is resistant to corrosion. The threads of the aquatherm red pipe-sprinkler connection fittings are made from brass (CuZn36Pb2As). Experiences with this material confirm that the alloy has an excellent re- sistance against concrete. The general building regulations have to be complied with locally. If special chemical additives (retarder, etc.) are applied, information from the manu- facturer of the concrete should be gathered; refer to aquatherm for suitablity. LAyING OF AqUATHeRM Red PiPe IN THE CONCRETE LAyinG in THe concReTe 58 All sprinkler pipelines shall be subjected to a hydraulical pressure test with a test-pressure of 10 bar. The material properties of the aquatherm red pipes result in an expansion of the pipes during the pressure test. This affects the test result. Due to the thermal expansion coefficients of the aquatherm red pipes the results are influenced additionally. The temperature differences between the pipe and the test medium lead to changes in pressure. Hereby a temperature change of 10 K corresponds to a pressure difference of 0,5 up to 1 bar. Therefore pressure testing of the aquatherm red pipe systems should be made with a constant temperature of the test medium. The hydraulic pressu- re test requires a preliminary, principal and final test. In the preliminary test a pressure of 18 bar is applied 3 x 5 minutes for the expansion/release of the pipes. Between the cycles the pipe system must be depressurized. Immediately after the preliminary test the principal test should be performed. The test duration is 15 min. Here, the test pressure (10 bar) may not fall more than 0,5 bar. After completion of the preliminary and principle test finally the final test must be performed. The test duration is 60 minutes. Here, the test pressure - read after the prin- ciple test - may not fall more than 0,5 bar. Measuring of the test pressures Measuring has to be done with a manometer allowing a perfect reading of a pressure change of 0.1 bar. The manometer has to be placed at the deepest point of the installation. Test record A record of the hydraulic pressure test has to be prepared and signed by the client and contractor stating place and date (see pages 60/61). LeAkAGe TeST TeST 59 TeST LeAkAGe TeST / PReSURe diAGRAM PRinciPAL- And FinAL TeST Principal test Final test 15 min Dpmax = 0,5 bar Dpmax = 0,5 bar Working pressure 10 bar 75 min PReLiMinARy TeST Working pressure 18 bar 0 bar 5 min 5 min 5 min 60 TeST RecoRd AqUATHeRM Red PiPe SySTeM inSTALLATion TeST Test record aquatherm system installation Place: Object: note before the test: 3x 5 minutes system pressure of 18 bar for expansion/release of the pipes are required. Preliminary test The pipe system must be unpressurized between each cycle. 18 bar 5 min realized: yes no 18 bar 5 min realized: yes no 18 bar 5 min realized: yes no Principal test Test pressure: 10 bar Pressure decline after 15 min: bar max. 0,5 bar Final test (directly after the principal test, without changing the pressure) Result principal test: bar Pressure decline after 60 min: bar max. 0,5 bar Notes: Place: Date: Stamp / Signature 61 TeST description of installation Place: Object: Pipe length: Ø 20 mm m Ø 25 mm m Ø 32 mm m Ø 40 mm m Ø 50 mm m Ø 63 mm m Ø 75 mm m Ø 90 mm m Ø 125 mm m Ø 160 mm m Start of test: End of test: Testperiod: Test medium: water water/glycol Client: Contractor: Place: Date: Stamp / Signature 62 enquiry for the chemical resistance of the aquatherm red pipe-pipe system aquatherm GmbH Technical department Biggen 5 . D-57439 Attendorn E-mail: info@aquatherm.de Phone: 02722 950-0 . Fax: 02722 950-100 internet: www.aquatherm.de installer: Field of application: installer Fluid transported: Company Operating temperature °C Street Working pressure bar City Service life h / d Phone Concentration % Fax E-mail building project: Ambient medium: Ambient temperature °C Ambient pressure bar building project: Street City Place, Date / Signature not data sheets enclosed enclosed Fluid transported Ambient medium AqUATHeRM AqUATHeRM Red PiPe SySTeM enquiry for the chemical resistance TeST 510 CPVC - COPPER - HANGER STEEL SIZE - SYSTEM PIPE: MATERIAL FINISH FUNCTION INSTALLATION P FASTENERS WOOD STEEL FEATURES #905 ORDERING 3/4 thru 3" - Carbon Steel. - Mil. Galvanized. -S - - in : 3/4" - 3" CPVC pipe - 3/4" - " Steel pipe - 1/4 x11/2 lag - no pre-drill. in 3/4" - 3" CPVC - * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. * Required screw included - 5/16" hex head. - Part # and pipe size. AFCON " upport horizontal piping: 3/4" -3" CPVC. Support horizontal piping: 3/4"-2" Steel and Copper. Size 3/4" - 2" provides listed vertical/lateral restraint and prevents upward movement of pipe that supplies a pendent sprinkler below a ceiling. Stabilize vertical piping. including NFPA13, 13R, 13D and CPVC manufacturers instructions. Install on horizontal or vertical mounting surface. screw - no pre-drill. 2 and Copper " " bolt min. 18 GA. pipe 1/4" or #14 Tek Screw. 3/4" - 2" Steel and Copper pipe - 1/4" or #14 Tek Screw. LISTING/APPROVAL- 203 - EX 4231, EX 2551 er these instructions #905 - UL Listed per NFPA13 Hanger Stabilize -Only CANALSO BE USED TO REPLACE - #500 Pipe Strap #520 Tin Strap Specific products are exclusively designed to be compatible with other products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. the following warranty restriction will apply. - will warrant against the failure of its products when used in combination with other products, partsor systems not manufactured or sold by . shall be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non- products have been, or are used. AFCON AFCON AFCON AFCON AFCON AFCON ONLY Be advised DISCLAIMER NOT NOT 1/12 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org C 3/4 1 11/4 11/2 2 21/2 3 510 SIZE 2.125 2.312 3.170 3.400 4.010 4.320 5.320 L Fastener Dim.CL- CADCADCAD 511 CPVC - COPPER HANGERSIDE MOUNT SIZE SYSTEM PIPE: MATERIAL FINISH FUNCTION INSTALLATION , WOOD #905 STEEL FEATURES #905 ORDERING - 3/4" thru 2" - Carbon Steel. - Mil. Galvanized. - Support horizontal piping - CPVC or Copper. Stabilize vertical piping. - including NFPA13, 13R 13D and CPVC manufacturers instructions. Install on vertical mounting surface. in : CPVC pipe - Copper pipe - screw - no pre-drill. in CPVC pipe - Copper pipe - 1/4 or #14 Tek Screw. * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. * Required screw included - 5/16" hex head. - Part # and pipe size. ” AFCON LISTING/APPROVAL- 203 - EX 4231, EX 2551 Per these instructions FASTENERS #905 - - UL Listed per NFPA13. 3/4" - 2" screw - no pre-drill. 3/4" - 2" min. 18 GA. 3/4" - 2" 1/4 or #14 Tek Screw. 3/4" - 2" ” Side View - For Drawings Below Hanger - Metal Stud Hanger - Wood Stud Specific products are exclusively designed to be compatible with other products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. the following warranty restriction will apply. - will warrant against the failure of its products when used in combination with other products, partsor systems not manufactured or sold by . shall be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non- products have been, or are used. AFCON AFCON AFCON AFCON AFCON AFCON ONLY Be advised DISCLAIMER NOT NOT 9/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org CADCADCAD 513 CPVC - STEEL- COPPER HANGER SIZE - SYSTEM PIPE: MATERIAL FINISH FUNCTION INSTALLATION FEATURES #905 ORDERING 3/4" thru 2" pipe. - Carbon Steel. - Mil. Galvanized. - Support horizontal piping - Tab up = Hanger. Stabilize vertical piping. - including NFPA13, 13R and 13D on and CPVC manufacturers instructions. Install on vertical mounting surface. * Offset edge eliminates abrasion. * Required screw included - 5/16" hex head. - Part # and pipe size. AFCON LISTING/APPROVAL- 203 - EX 4231, EX 2551 Per these instructions FASTENERS WOOD #905 #905 CPVC, Copper or Steel. - UL Listed per NFPA13. in : 3/4" - 2" CPVC pipe - screw - no pre-drill. 3/4" - 2" Copper pipe - screw - no pre-drill. 3/4" - 2" Steel pipe - 1/4"x1 1/2" lag screw - no pre-drill. Hanger Stabilize -Only Specific products are exclusively designed to be compatible with other products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. the following warranty restriction will apply. - will warrant against the failure of its products when used in combination with other products, partsor systems not manufactured or sold by . shall be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non- products have been, or are used. AFCON AFCON AFCON AFCON AFCON AFCON ONLY Be advised DISCLAIMER NOT NOT 3/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org CADCADCAD 514 OFFSET HANGER CPVC - COPPER STEEL• SIZE SYSTEM PIPE: MATERIAL FINISH PATENT No. 6,648,278. FUNCTION INSTALLATION WOOD - #905 STEEL- FEATURES #905 ORDERING 906 - 3/4" thru 3" - Carbon Steel. - Mil. Galvanized.. - -S rovid vertical ateral restraint revents upward movement of pipe that supplies a pendent sprinkler below ceiling. - including NFPA13, 13R, 13D and CPVC manufacturers instructions. Install on horizontal or vertical mounting surface. Snap over pipe then squeeze strap back allowing pipe to slide freely. CPVC pipe - screw- no pre-drill. Copper pipe - Steel pipe - 1/4 x1 lag screw - 5/8 gypsum board - 1/4 x lag screw min. * 1 1/2 Offset * 3/4 and 1 pipe size a e common center-line. * Patented design for superior strength. * Offset edge eliminates abrasion. * screw included - 5/16" hex head. - Part # and pipe size. # backing nut sold separately. AFCON AFCON LISTING/APPROVAL- 203 - EX 4231, EX 2551 Per these instructions FASTENERS #905 CONCRETE each = upport horizontal piping: 3/4" -3" CPVC or Copper. Support horizontal piping: 3/4" - 2" Steel. Size 3/4" - 2" p es listed /l and p a Stabilize vertical piping. When #905 threads are exposed in wood, install #906 backing nut. - UL Listed per NFPA13 3/4" - 3" 3/4" - 2" screw- no pre-drill. 3/4" - 2" " 1/2" no pre-drill. Thru " " 2" . 18 GA. - 3/4" - 3" CPVC pipe - 1/4" or #14 Tek Screw. 3/4" - 2" Copper pipe - 1/4" or #14 Tek Screw. 3/4" - 2" Steel pipe - 1/4" or #14 Tek Screw. : Required minimum load fastener " - loose fit allows pipe to slide. " " m d with • 5(wt)+250lbs. 2 1.5000 #905 #906 Listed Restraint Listed Restraint Specific products are exclusively designed to be compatible with other products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. the following warranty restriction will apply. - will warrant against the failure of its products when used in combination with other products, partsor systems not manufactured or sold by . shall be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non- products have been, or are used. AFCON AFCON AFCON AFCON AFCON AFCON ONLY Be advised DISCLAIMER NOT NOT 3.00 10/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 3/4 thru 2"" 3/4 thru 2"" CADCADCAD 515 CPVC DOUBLE OFFSET HANGER SIZE-SYSTEM PIPE: MATERIAL FINISH PATENT - No. 6,702,236 FUNCTION INSTALLATION FASTENERS WOOD #904 FEATURES #904 ORDERING 3/4" and 1" - Carbon Steel. - Mil. Galvanized. - Support/Restrain horizontal CPVC piping. - including NPFA13, 13R, 13D and CPVC manufacturers instructions. Install on horizontal or vertical mounting surface. - UL Listed per NFPA13. : screw - no pre-drill. * Double 1 1/2" offset * Center line matches #514. * * Required screw included - 3/8" hex head. - Part # and pipe size. AFCON AFCON LISTING/APPROVAL- 203 - EX 4231 Per these instructions 3/4" and 1" 3/4" and 1" pipe size have common center-line. * Offset edge eliminates abrasion. Specific products are exclusively designed to be compatible with other products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. the following warranty restriction will apply. - will warrant against the failure of its products when used in combination with other products, partsor systems not manufactured or sold by . shall be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non- products have been, or are used. AFCON AFCON AFCON AFCON AFCON AFCON ONLY Be advised DISCLAIMER NOT NOT 1.00 3/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org CADCAD 519 CPVC HANGERADJUSTABLE SIZE SPRINKLER THREADS: MATERIAL FINISH PATENT FUNCTION / INSTALLATION Per these instructions ASSEMBLY - See drawing. see note FASTENERS WOOD #904 FEATURES #904 ORDERING - 1/2" and 3/4 npt. - Carbon Steel. - Plain. - - Support restrain CPVC piping at the sprinkler head. Provide vertical adjustment. - including NPFA 13, 13R, 13D and CPVC manufacturers instructions. Install on vertical mounting surface. Combine with appropriate sprinkler canopy Insert correct sprinkler head through #519 bore, then thread into CPVC adapter. Verify assembled product prior - may not fit some product combinations - . - UL Listed per NFPA13. in : screws - no pre-drill. * 1" adjustment using a screw driver. matches #514 and #515. * Required screw included - 3/8” hex head. - Part # and size. * AFCON AFCON " * 1 1/2" offset LISTING/APPROVAL- 203 - EX 4231 No. 6,755,379, No. 6,783,102, No. 7,017,868 1.7000 1.0757 Canopy I.D. = 2 1/4”min. *Note - some canopies won’t accommodate the #519 #519 uses the between the sprinkler head and the sprinkler fitting as a point of mounting attachment. This is the only available uniform point of attachment not detrimental to the CPVC piping. Beware - some canopy designs conflict with the installation of the #519. Do not install the #519 when canopies have conflicting geometry or dimensions. Examples are: • Flared canopy hole may conflict with • Required canopy . = min standard thread gap standard thread gap I.D 2 1/4” . 1.6636 Specific products are exclusively designed to be compatible with other products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. the following warranty restriction will apply. - will warrant against the failure of its products when used in combination with other products, partsor systems not manufactured or sold by . shall be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non- products have been, or are used. AFCON AFCON AFCON AFCON AFCON AFCON ONLY Be advised DISCLAIMER NOT NOT 4/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org CADCAD Series 2000B Double Check Valve Assemblies are designed to protect drinking water sup-plies for dangerous cross-connections in accordance with national plumbing codes and water authority requirements for non-health-hazard non-potable service applications such as irrigation, fire line, or industrial processing. These valves meet the requirements of ASSE Std. 1015 and AWWA Std. C510 and are approved by the Foun da tion for Cross-Con nec tion Control and Hy drau lic Re search at the University of South ern California. Specifications A Double Check Valve Assembly shall be installed at each not ed lo ca tion. The as sem bly shall con sist of two positive seat ing check mod ules with cap tured springs and rubber seat discs. The check module seats and seat discs shall be re place able. Ser vice of all internal com po nents shall be through a sin gle ac cess cover se cured with stainless steel bolts. The as sem bly shall also in clude two resilient seat ed iso la tion valves and four top mount ed, re sil ient seat ed test cocks. The as sem bly shall meet the re quire ments of ASSE Std. 1015 and AWWA Std. C510. Ap proved by the Foun da tion for Cross-Con nec tion Control and Hy drau lic Re search at the Uni ver si ty of South ern Cal i for nia. As sem bly shall be an Ames Company Series 2000B. Approvals Approved by the Foundation for Cross-Connection Control and Hy drau lic Research at the University of Southern California. LBV models not listed. Horizontal and vertical "flow up" approval on all sizes. ES-A-2000B 3⁄4" 2000B (20mm) 2" 2000B HC (50mm) Series 2000B Double Check Valve Assemblies Sizes: 1⁄2" – 2" (15 – 50mm) Job Name ________________________________________________Contractor ______________________________________________ Job Location ______________________________________________Approval _______________________________________________ Engineer _________________________________________________Contractor’s P.O. No. ______________________________________ Approval _________________________________________________Representative ___________________________________________ Ames product specifications in U.S. customary units and metric are ap prox i mate and are pro vid ed for ref er ence only. For precise mea sure ments, please contact Ames Technical Ser vice. Ames reserves the right to change or modify prod uct de sign, con struc tion, spec i fi ca tions, or ma te ri als with out prior notice and without in cur ring any ob li ga tion to make such chang es and mod i fi ca tions on Ames products previously or sub se quent ly sold.amesfirewater.com Features • Ease of maintenance with only one cover • Top entry • Replaceable seats and seat discs • Modular construction • Compact design • 1⁄2" – 2" (15 – 50mm) Cast bronze body construction • Top mounted ball valve test cocks • Low pressure drop • No special tools required • 1⁄2" – 1" (15 – 25 mm) have tee handles Available Models Suffix: B - Quarter turn ball valves LBV - less ball valves SH - stainless steel ball valve handles HC - 21⁄2" inlet/outlet fire hydrant fit ting (2" valve) Pressure — Temperature Temperature Range: 33°F – 140°F (0.5°C – 60°C) Maximum Working Pressure: 175psi (12.1 bar) Standards AWWA Std. C510, IAPMO PS31 1015 B64.5 3⁄4" - 2"(LBV Models Only) It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material prod-uct, consult your local water authority, building and plumbing codes. WARNING! Capacities As compiled from documented Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California lab tests. ∆Typical maximum system flow rate (7.5 feet/sec., 2.3 meters/sec.) kPa psi 83 12 69 10 55 8 41 6 28 4 14 2 0 0 ∆P 0 2 4 6 8 10 12 gpm0 7.6 15.2 22.8 30.4 38 45.6 lpm 5 7.5 10 fps 1.5 2.3 3.0 mps ∆ ∆P * ∆P ∆ kPa psi 110 16 83 12 69 10 55 8 41 6 28 4 14 2 0 5 10 15 20 25 30 35 40 45 50 55 60 gpm0 19 38 57 76 95 114 133 152 171 190 209 228 lpm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps ∆P ∆ kPa psi 96 14 83 12 69 10 55 8 41 6 28 4 14 2 0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm0 38 76 114 152 190 228 266 304 342 380 418 456 lpm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps kPa psi 83 12 69 10 55 8 41 6 28 4 14 2 0 0 ∆P0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 38 76 114 152 190 228 266 304 342 380 418 456 lpm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps ∆ ∆P ∆ kPa psi 83 12 69 10 55 8 41 6 28 4 14 2 0 0 0 25 50 75 100 125 150 175 200 gpm0 95 190 285 380 475 570 665 760 lpm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps 1⁄2" (15mm) 1" (25mm) 11⁄4" (32mm) 11⁄2" (40mm) 2" (50mm) kPa psi 152 22 124 18 96 14 69 10 41 6 14 2 3⁄4" (20mm) 0 5 10 15 20 25 30 35 40 45 50 gpm0 19 38 57 76 95 114 133 152 171 190 lpm 7.5 15 fps 2.3 4.6 mps ∆ Dimensions – Weights Size (dn) diMenSiOnS WeigHt A B C F G H I in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 1⁄2 15 10 254 45⁄8 117 27⁄16 62 5 127 33⁄8 85 25⁄16 59 21⁄16 52 4.5 2 3⁄4 20 111⁄8 282 4 102 31⁄8 79 63⁄16 157 37⁄16 87 21⁄8 54 15⁄16 33 5 2.3 1 25 131⁄4 337 51⁄8 130 4 102 71⁄2 191 33⁄8 85 111⁄16 43 111⁄16 43 12 5.4 11⁄4 32 163⁄8 416 5 127 35⁄16 84 91⁄2 241 5 127 3 76 2 50 15 6.8 11⁄2 40 163⁄4 425 47⁄8 124 31⁄2 89 93⁄4 248 513⁄16 148 31⁄8 79 211⁄16 68 15.86 7.2 2 50 191⁄2 495 61⁄4 159 4 102 133⁄8 340 61⁄8 156 37⁄16 87 211⁄16 68 25.75 11.7 H g iSuffix HC — Fire Hydrant Fittings dimension "A" = 231⁄2" (594mm) C B F A Strainer sold separately Pressure LossPressure LossPressure LossPressure LossPressure LossPressure LossFlow Rate Flow Rate Flow Rate Flow Rate Flow Rate Flow Rate ES-A-2000B 1410 © 2014 Ames Fire & Waterworks USA: Backflow Tel: (978) 689-6066 • Fax: (978) 975-8350 • AmesFireWater.com USA: Control Valves Tel: (713) 943-0688 • Fax: (713) 944-9445 • AmesFireWater.com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • AmesFireWater.ca Latin America: Tel: (52) 81-1001-8600 • Fax: (52) 81-8000-7091 • AmesFireWater.com A Watts Water Technologies Company Series 2000B Double Check Valve Assemblies are designed to protect drinking water sup-plies for dangerous cross-connections in accordance with national plumbing codes and water authority requirements for non-health-hazard non-potable service applications such as irrigation, fire line, or industrial processing. These valves meet the requirements of ASSE Std. 1015 and AWWA Std. C510 and are approved by the Foun da tion for Cross-Con nec tion Control and Hy drau lic Re search at the University of South ern California. Specifications A Double Check Valve Assembly shall be installed at each not ed lo ca tion. The as sem bly shall con sist of two positive seat ing check mod ules with cap tured springs and rubber seat discs. The check module seats and seat discs shall be re place able. Ser vice of all internal com po nents shall be through a sin gle ac cess cover se cured with stainless steel bolts. The as sem bly shall also in clude two resilient seat ed iso la tion valves and four top mount ed, re sil ient seat ed test cocks. The as sem bly shall meet the re quire ments of ASSE Std. 1015 and AWWA Std. C510. Ap proved by the Foun da tion for Cross-Con nec tion Control and Hy drau lic Re search at the Uni ver si ty of South ern Cal i for nia. As sem bly shall be an Ames Company Series 2000B. Approvals Approved by the Foundation for Cross-Connection Control and Hy drau lic Research at the University of Southern California. LBV models not listed. Horizontal and vertical "flow up" approval on all sizes. ES-A-2000B 3⁄4" 2000B (20mm) 2" 2000B HC (50mm) Series 2000B Double Check Valve Assemblies Sizes: 1⁄2" – 2" (15 – 50mm) Job Name ________________________________________________Contractor ______________________________________________ Job Location ______________________________________________Approval _______________________________________________ Engineer _________________________________________________Contractor’s P.O. No. ______________________________________ Approval _________________________________________________Representative ___________________________________________ Ames product specifications in U.S. customary units and metric are ap prox i mate and are pro vid ed for ref er ence only. For precise mea sure ments, please contact Ames Technical Ser vice. Ames reserves the right to change or modify prod uct de sign, con struc tion, spec i fi ca tions, or ma te ri als with out prior notice and without in cur ring any ob li ga tion to make such chang es and mod i fi ca tions on Ames products previously or sub se quent ly sold.amesfirewater.com Features • Ease of maintenance with only one cover • Top entry • Replaceable seats and seat discs • Modular construction • Compact design • 1⁄2" – 2" (15 – 50mm) Cast bronze body construction • Top mounted ball valve test cocks • Low pressure drop • No special tools required • 1⁄2" – 1" (15 – 25 mm) have tee handles Available Models Suffix: B - Quarter turn ball valves LBV - less ball valves SH - stainless steel ball valve handles HC - 21⁄2" inlet/outlet fire hydrant fit ting (2" valve) Pressure — Temperature Temperature Range: 33°F – 140°F (0.5°C – 60°C) Maximum Working Pressure: 175psi (12.1 bar) Standards AWWA Std. C510, IAPMO PS31 1015 B64.5 3⁄4" - 2"(LBV Models Only) It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material prod-uct, consult your local water authority, building and plumbing codes. WARNING! Capacities As compiled from documented Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California lab tests. ∆Typical maximum system flow rate (7.5 feet/sec., 2.3 meters/sec.) kPa psi 83 12 69 10 55 8 41 6 28 4 14 2 0 0 ∆P 0 2 4 6 8 10 12 gpm0 7.6 15.2 22.8 30.4 38 45.6 lpm 5 7.5 10 fps 1.5 2.3 3.0 mps ∆ ∆P * ∆P ∆ kPa psi 110 16 83 12 69 10 55 8 41 6 28 4 14 2 0 5 10 15 20 25 30 35 40 45 50 55 60 gpm0 19 38 57 76 95 114 133 152 171 190 209 228 lpm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps ∆P ∆ kPa psi 96 14 83 12 69 10 55 8 41 6 28 4 14 2 0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm0 38 76 114 152 190 228 266 304 342 380 418 456 lpm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps kPa psi 83 12 69 10 55 8 41 6 28 4 14 2 0 0 ∆P0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 38 76 114 152 190 228 266 304 342 380 418 456 lpm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps ∆ ∆P ∆ kPa psi 83 12 69 10 55 8 41 6 28 4 14 2 0 0 0 25 50 75 100 125 150 175 200 gpm0 95 190 285 380 475 570 665 760 lpm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps 1⁄2" (15mm) 1" (25mm) 11⁄4" (32mm) 11⁄2" (40mm) 2" (50mm) kPa psi 152 22 124 18 96 14 69 10 41 6 14 2 3⁄4" (20mm) 0 5 10 15 20 25 30 35 40 45 50 gpm0 19 38 57 76 95 114 133 152 171 190 lpm 7.5 15 fps 2.3 4.6 mps ∆ Dimensions – Weights Size (dn) diMenSiOnS WeigHt A B C F G H I in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 1⁄2 15 10 254 45⁄8 117 27⁄16 62 5 127 33⁄8 85 25⁄16 59 21⁄16 52 4.5 2 3⁄4 20 111⁄8 282 4 102 31⁄8 79 63⁄16 157 37⁄16 87 21⁄8 54 15⁄16 33 5 2.3 1 25 131⁄4 337 51⁄8 130 4 102 71⁄2 191 33⁄8 85 111⁄16 43 111⁄16 43 12 5.4 11⁄4 32 163⁄8 416 5 127 35⁄16 84 91⁄2 241 5 127 3 76 2 50 15 6.8 11⁄2 40 163⁄4 425 47⁄8 124 31⁄2 89 93⁄4 248 513⁄16 148 31⁄8 79 211⁄16 68 15.86 7.2 2 50 191⁄2 495 61⁄4 159 4 102 133⁄8 340 61⁄8 156 37⁄16 87 211⁄16 68 25.75 11.7 H g iSuffix HC — Fire Hydrant Fittings dimension "A" = 231⁄2" (594mm) C B F A Strainer sold separately Pressure LossPressure LossPressure LossPressure LossPressure LossPressure LossFlow Rate Flow Rate Flow Rate Flow Rate Flow Rate Flow Rate ES-A-2000B 1410 © 2014 Ames Fire & Waterworks USA: Backflow Tel: (978) 689-6066 • Fax: (978) 975-8350 • AmesFireWater.com USA: Control Valves Tel: (713) 943-0688 • Fax: (713) 944-9445 • AmesFireWater.com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • AmesFireWater.ca Latin America: Tel: (52) 81-1001-8600 • Fax: (52) 81-8000-7091 • AmesFireWater.com A Watts Water Technologies Company Installation Installation of the three-way valve can be accomplished with normal field installation tools. Make sure the valve is installed according to the flow indication arrow that has been cast into the valve body. The most common installation allows for a 1/4” IPS nipple between the valve and the water supply being measured. This assures there will be ad- equate spacing for the sprinkler system gauge from the riser. Use either PTFE Pipe Thread Sealing Tape or a suitable pipe thread sealant such as PipeFit® Thread Sealant Paste with PTFE when installing the valve. DO NOT OVERTIGHTEN THREADS. OVERTIGHTENING MAY CAUSE VALVE FAILURE. *UL/ULC Listed 2R97 Specifications Materials: Seat - Brass Body - Brass Handwheel - Iron Sizes: 1/4” IPS Working Pressure: 400 WOG 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1 760 599-1168 + 1 800 344-1822 FAX + 1 800 344-3775 © 2012 Fire Protection Products, Inc. Description The 1/4” IPS three-way female threaded valve is used to facilitate the installation of sprinkler system pressure gauges. The valve provides for one inlet and two outlets. This design allows for replacement of the system gauge without shutting down the water supply to the sprinkler system. This design also allows Authorities’ Having Jurisdiction to test system pressure with an additional gauge through the second outlet. (The second outlet is normally plugged during installation with a 1/4” IPS pipe plug.) WWW.FPPI.COM Three-way Brass Valve 1/4’’ IPS UL/ULC Listed* 300 psi Warning DO NOT OVER TIGHTEN. Over tightening during installation will crack the valve body. Evidence of overtightening may not be readily visible or apparent upon pressurization. Installation For horizontal installation only. The female by female swing check valve should be installed in accordance with commonly used installation practices for the fire sprinkler industry. Proper seal of the threads can be accomplished by applying a liberal amount of PTFE based thread seal- ant such as PipeFit® Thread Sealant Paste or PTFE Tape. Never use tape and paste together. This will cause excessive stress on the threaded connection leading to failure of the valve. Do not exceed one full turn past hand tight when installing male threads into the check valve. Specifications Valve Body: Cast Bronze* (85-5-5-5) Clapper Assembly: Forged Brass Seat: NBR (Chloramine Resistant) Sizes: 1/2” IPS 2” IPS Female by female Rated Pressure: 250 psi *Contains lead. Not for use in water systems intended for human consumption. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1 760 599-1168 + 1 800 344-1822 FAX + 1 800 344-3775 © 2012 Fire Protection Products, Inc. Description The bronze* swing check valve features a full floating clapper assembly that provides for a positive seal each time the valve is cycled. This feature improves the swing check valves ability to “clear” any debris that may be present in the water supply. The seat material is NBR which provides for a positive seal even under light residual pressures. WWW.FPPI.COM Swing Check Valve Full Floating Clapper Assembly PRINTED IN USA MFG. #5401206 - REV G 12/08 VSR-S VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD FOR SMALL PIPE PAGE 1 OF 3 Stock No. 1144440 The Model VSR-S is a vane type waterfl ow switch for use on wet sprinkler systems that use 1" (25mm), 1¼" (32mm), 1½" (38mm) or 2" (50mm) pipe size. The unit may also be used as a sectional waterfl ow detector on large systems. The unit contains two single pole double throw snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a fl ow of 10 gallons per minute (38 LPM) or more occurs downstream of the device. The fl ow condition must exist for a period of time necessary to overcome the selected retard period. Enclosure The VSR-S switches and retard device are enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A fi eld installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin number 5401103 for installation instructions of this switch. Installation These devices may be mounted in horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will be accessible. The units should not be installed within 6" (15cm) of a valve, drain or fi tting which changes the direction of the waterfl ow. Select the proper paddle for the pipe size and type of TEE used see Fig. 1 for instructions on changing paddle. The unit has a 1" NPT bushing for threading into a non-corrosive TEE. See Fig. 2 for proper TEE size, type and installation. Use no more than three wraps of tefl on tape. Screw the device into the TEE fi tting as shown in Fig. 2. Care must be taken to properly orient the device for the direction of waterfl ow. The vane must not rub the inside of the TEE or bind in any way. The stem should move freely when operated by hand. The device can also be used in copper or plastic pipe installations with the proper adapters so that the specifi ed TEE fi tting may be installed on the pipe run. Note: Do not leave cover off for an extended period of time. Potter Electric Signal Company, LLC • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com UL, ULC, CSFM Listed and NYMEA Accepted Service Pressure: Up to 300 PSI (20,7 BAR) Flow Sensitivity Range for Signal: 4-10 GPM (15-38 LPM) UL Maximum Surge: 18 FPS (5,5 m/s) Enclosure: Die-cast, red enamel fi nish Cover held in place with tamper resistant screws Contact Ratings: Two sets of SPDT (Form C) 10.0 Amps at 125/250 VAC 2.0 Amps at 30 VDC Resistive 10mAmps min. at 24 VDC Conduit Entrances: Two openings provided for 1/2" conduit. Individual switch compartments suitable for dissimilar voltages. Usage: Listed plastic, copper and schedule 40 iron pipe. Fits pipe sizes - 1" (25mm), 1 1/4" (32mm), 1 1/2" (38mm) and 2" (50mm) Note: 12 paddles are furnished with each unit, one for each pipe size of threaded and sweat TEE, one for 1" (25mm) CPVC, one for 1" (25mm) CPVC (Central), one for 1" threaded Nibco CPVC, and one for 1 1/2" (38mm) threaded (Japan). Environmental Specifi cations: • NEMA-4/IP54 Rated enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fi tting.• Temperature range: 40° F to 120° F, (4,5° C to 49° C) UL Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 Optional: Cover Tamper Switch Kit, Stock No. 0090148 (See Fig. 7 for terminations) Replaceable Components: Retard/Switch Assembly, stock no. 1029030 Installation must be perfomed by qualifi ed personnel and in accordance with all national and local codes and ordinances. Shock hazard. Disconnect power source before servicing. Serious injury or death could result. Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. 4440 PRINTED IN USA MFG. #5401206 - REV G 12/08 VSR-S VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD FOR SMALL PIPE PAGE 2 OF 3 COVER TAMPER SWITCH MOUNT SO ARROW ON BUSHING POINTS IN DIRECTION OF WATERFLOW 1” NPT THREADED FITTING ON ALL SIZES RUN OF THE TEE MAY BE THREADED OR SWEAT PIPE DIRECTION OF WATERFLOW DWG# 802-30A Fig. 1 Fig. 2 Notes: 1. The Model VSR-S has two switches, one can be used to operate a central station, proprietary or remote signaling unit, while the other is used to operate a local audible or visual annunciator. 2. For supervised circuits see “Switch Terminal Connections” drawing and caution note (Fig. 3). Retard Adjustment The time delay is factory set at 30 ± 10 seconds. The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting (60- 90 seconds). The time delay should be set at the minimum required to prevent false alarms. Fig. 3 Switch Terminal Connections Clamping Plate Terminal OUTG O I N G INCO M I N G DWG# 923-3 To remove knockouts: Place screwdriver at edge of knockouts, not in the center. Screw the device into the tee fi tting as shown. Care must be taken to properly orient the device for the direction of waterfl ow. On sweat tees, no threaded bushings, inserts, or adapters are permitted, unless they comply with the dimensions listed in the chart below. Important - The depth to the inside bottom of the tee should have the following dimensions: DIRECTION OF WATER FLOW DWG# 737-31 Shown with optional Cover Tamper Switch Kit. DWG# 1146-4 DWG# 8810018-2 C (WHT) N.O. (RED) N.C. (BLK) Fig. 7 Cover Tamper Switch Wiring (Shown with cover in place) DO NOT LEAVE COVER OFF FOR EXTENDED PERIOD OF TIME 4,3MM (1 11/16”)APPROX. DEPTH DWG# 735-33 Approximate Depth Requirement Tee Size Threaded Sweat CPVC 1" x 1" x 1" 2 1/16" 1 3/4" 2 7/16" 1 1/4" x 1 1/4" x 1" 2 7/16" 2 7/16" N/A 1 1/2" x 1 1/2" x 1" 2 11/16" 2 1/4" N/A 2" x 2" x 1" 3 3/16" 2 3/4" N/A DWG# 1146-3A POSITIVE DC OR HOT AC NEGATIVE DC OR NEUTRAL AC WATERFLOW ZONE ON FIRE PANEL BELL EOLRCOMNCNO NONCCOMBreak out thin section of cover when wiring both switches from one conduit entrance. DWG# 1206-2 An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. Fig. 4 Typical Electrical Connections Fig. 5 Fig. 6 There are 12 paddles furnished with each unit. One for each size of threaded, sweat or plastic TEE as described in Fig. 2. These paddles have raised lettering that shows the pipe size and type of TEE that they are to be used with. The proper paddle must be used. The paddle must be properly attached (see drawing) and the screw that holds the paddle must be securely tightened.Do not use more than three wraps of tefl on tape. PRINTED IN USA MFG. #5401206 - REV G 12/08 VSR-S VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD FOR SMALL PIPE PAGE 3 OF 3 Testing The frequency of inspection and testing for the Model VSR-S and its associated protective monitoring system should be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently.) An inspector's test valve (usually located at the end of the most remote branch line) should always be used for test purposes. If there are no provisions for testing the operation of the fl ow detection device on the system, application of the VSR-S is not recommended or advisable. A minimum fl ow of 10 gpm (38 Lpm) is required to activate this device. Please advise the person responsible for testing of the fi re protection system that this system must be tested in accordance with the testing instructions. Maintenance Inspect detectors monthly for leaks. If leaks are found, replace the detector. The VSR-S waterfl ow switch should provide years of trouble- free service. The retard and switch assembly are easily fi eld replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock #1029030. There is no maintenance required, only periodic testing and inspection. DWG# 1206-5 GROUND SCREWS 3.50"5.56" (89.0 mm) (59.4 mm) 2.34" (141.2 mm) (52.3 mm) 4.89" 2.00" (50.8 mm) 1"-11 1/2 NPT Mounting Dimensions Waterfl ow switches that are monitoring wet pipe sprinkler systems shall not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterfl ow switches used for this application may result in unintended discharges caused by surges, trapped air, or short retard times. Removal • To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterfl ow detectors are removed or replaced. • Turn off electrical power to the detector, then disconnect wiring. • Use a wrench on the fl ats of the bushing. Turn the switch counterclockwise to disengage the pipe threads. • Gently lift with your fi ngers, roll the vane so it will fi t through the hole while continuing to lift the waterfl ow detector. • Lift detector clear of pipe. MFG. #5401076 - REV H 5/08 UL Listed Strobe Horn Dimensions: 9-1/4" h x 10" w x 4" d Voltages Available: SASH-24 (24VDC) SASH-120 (120VAC) Environment: Indoor or Outdoor use Weatherproof backbox is included with both models Termination: Separate terminals for horn and strobe Finish: Red with white lettering SASH-24 Stock No. 1000555 SASH-120 Stock No. 1000560 The SASH series is a multitone horn/strobe combination designed for use as an audio visual indication for automatic sprinkler systems. It can be installed in conjunction with or in place of water motor gongs. SASH SERIES SPRINKLER ALARM STROBE HORN/SIGN COMBINATION PAGE 1 OF 1PRINTED IN USA Potter Electric Signal Company, LLC • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com Strobe Intensity, dBA, and Current Ratings Model SASH-24 Input Current SASH-120 Input Current Typical Anechoic dBA at 10 ft. Tone Amps at 24V DC Amps at 115V AC At Nominal Input Voltage HI STD HI STD HI STD Horn 0.038 0.024 0.050 0.040 99 93 Bell 0.019 0.012 0.040 0.038 92 87 March Time Horn 0.038 0.024 0.050 0.040 99 93 Code-3 Horn 0.038 0.024 0.050 0.040 99 93 Code-3 Tone 0.027 0.016 0.042 0.038 95 90 Slow Whoop 0.047 0.025 0.050 0.040 99 94 Siren 0.034 0.022 0.045 0.040 98 93 Hi/Lo 0.020 0.013 0.041 0.039 93 88 Strobe Candella 75 15 Strobe Current (If the strobe and audible operate on the same circuit, add the strobe current to the tone current.) 0.102 0.060 Wiring Information SASH-24 STROBE AND HORN POWERED BY THE SAME CIRCUIT SASH-24 STROBE AND HORN POWERED FROM SEPA- RATE CIRCUIT SASH-120 OPERATED BY WATERFLOW SWITCH DWG# 1076-1 STR AUD STR AUD CONTACTS CLOSE ON ALARM WATERFLOW SWITCH N STR L N AUD L GUARDIAN FIRE EQUIPMENT, INC. 58 Two and Three-Way Connections Model No.Outlet Size Clappers A B C D 6024 Back 4” x 2 1⁄2” x 21⁄2”2115⁄8”77⁄8” --- 7 5⁄8” 6025 Bottom 4” x 2 1⁄2” x 21⁄2”2121⁄8”67⁄8”71⁄8”75⁄8” 6026 Top 4” x 2 1⁄2” x 21⁄2”2121⁄8”67⁄8”71⁄8”75⁄8” 6027 Back 6” x 2 1⁄2” x 21⁄2”2115⁄8”77⁄8” --- 7 5⁄8” 6028 Bottom 6” x 2 1⁄2” x 21⁄2”2121⁄8”7” 7 1⁄8”75⁄8” 6029 Top 6” x 2 1⁄2” x 21⁄2”2121⁄8”8”9”7” 6034 Back 4” x 2 1⁄2” x 21⁄2” x 21⁄2”3173⁄8”61⁄8” --- 6 5⁄8” 6037 Back 6” x 2 1⁄2” x 21⁄2” x 21⁄2”3173⁄8”61⁄8” --- 6 5⁄8” 6038 Bottom 6” x 2 1⁄2” x 21⁄2” x 21⁄2”3173⁄8”75⁄8”71⁄8”65⁄8” 6039 Top 6” x 2 1⁄2” x 21⁄2” x 21⁄2”3173⁄8”75⁄8”71⁄8”65⁄8” Identifi cation Plate Lettering: • AUTO SPKR • STANDPIPE • AUTO SPKR & STANDPIPE • DRY STANDPIPE 6000 Series Flush Fire Dept. Inlet Connections 6002 6014/6015 Residential 6024-6029 6034-6039 Notes • Pipe nipples for connecting bodies to swivel inlets by others • Always specify hose threads and identifi cation plate lettering • Contact Guardian for current approvals and special requirements 6016/6017 Top/Bottom OutletBack Outlet B A B AC 9” 31⁄2” Dia. D 31⁄2” 21⁄2” Nipple(by others) Swivel Inlet Plug 15” Plate • Single inlet connections incorporate a straight-thru, non-clappered design with female NPT outlets • Two and three-way inlet connections feature brass bodies (angle or straight pattern), with integral drop-clapper inlets and female NPT outlets • Standard components, all connections: Female hose thread swivel inlets, plugs with chains and identifi cation plate • Cast brass construction*, standard *Optional brass fi nishes on exposed surfaces, add suffi x to model no. -B Polished; -C Rough Chrome Plated; -D Polished Chrome Plated Features/Components • Used as auxiliary connections through which the fi re department can pump water to supplement existing water supplies • Provides 250 GPM fl ow (minimum), per 21⁄2” inlet Function 31⁄2” Dia. B A B A CBack Outlet Top/Bottom Outlet Plate 9” 23” D 31⁄2” SwivelInlet Plug 21⁄2” Nipple(by others) Single Inlet Connections Model No.6002 6014 6015 6016 6017 Outlet 11⁄2”21⁄2”3”21⁄2”3 Inlet 11⁄2”21⁄2”21⁄2”21⁄2”21⁄2” Plate 41⁄2” O.D. 7” O.D. 7” O.D. 7” SQ 7” SQ Identifi cation Plate Lettering: AUTO SPKR GUARDIAN FIRE EQUIPMENT, INC. 63 Model 6414 4” x 18”Model 6416 6” x 18” 6400 Series Fire Dept. Inlet Connections - Accessories 6406/6407 **Important: Specify Hose Threads** 6408/6409 Swing Check Valve • Used to prevent water backfl ow 6402/6404 • Used on fi re department inlet connections to check backfl ow • Cast brass body, polished trim* Clappered Snoots *Optional polished chrome plated trim, add suffi x -D to model no. • See Models 3340 and 3345, page 31 Open Snoots • Used to drain water from the low point of the system Automatic Ball Drip • Used to manually drain water from the low point of the system Sillcock *Optional rough chrome plated fnish, add suffi x -C to model no. Plugs and Break Caps • Used to keep fi re dept. inlet connections free of debris and protect female threads *Optional brass fi nishes, add suffi x to model no. -B Polished; -C Rough Chrome Plated; -D Polished Chrome Plated • Used to conceal incoming pipe of free-standing fi re department connection, polished brass* Cover Sleeve *Optional polished chrome plated fi nish, add suffi x -D to model no. Wafer Check Valve • Used to prevent water backfl ow 6414/6416 6426/6428 64196418 6420-6422 77⁄8” 3” 53⁄8” 6430/6431 6435 4” : 67⁄8” Dia 6” : 81⁄2” Dia 4” : 41⁄4”6” : 33⁄4” Drain plug on 4” valve only 6” : 41⁄2” Dia4” : 3” Dia Waterway Model 6402 11⁄2” cast brass* plug with chain Model 6404 21⁄2” cast brass* plug with chain Model 6406 21⁄2” aluminum break cap Model 6407 21⁄2” plastic break cap Model 6408 21⁄2” aluminum adjustable plug Model 6409 21⁄2” plastic adjustable plug Model 6435 3⁄4” female NPT x male GHT, cast brass* Model 6418 21⁄2” female swivel inlet x 3” female NPT outlet Model 6419 21⁄2” female swivel inlet x 3” male NPT outlet Model 6420 4” groove x groove, cast brass Model 6421 4” NPT male x groove, cast brass Model 6422 4” NPT male x NPT female, cast brass Model 6426 4” cast iron Model 6428 6” cast iron Model 6430 1⁄2” NPT, male x male, straight, cast brass Model 6431 1⁄2” NPT, male x male, angle, cast brass Model 6432 3⁄4” NPT, male x male, straight, cast brass Model 6433 3⁄4” NPT, male x male, angle, cast brass Specifications Bourdon Tube Material: copper alloy C-type Pressure Connection Material: copper alloy 1/4“ NPT lower mount (LM) Movement Copper alloy Dial White aluminum with stop pin; black and red lettering Pointer Black aluminum Case Black polycarbonate Window Snap-in clear polycarbonate 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1 760 599-1168 + 1 800 344-1822 FAX + 1 800 344-3775 © 2012 Fire Protection Products, Inc. Standard Features Design EN 837-1 & ASME B40.100 Sizes 4” (100 mm) Accuracy class ± 31/2% of span (ASME B40.100 Grade B) Ranges 0/80 psi, retard to 250 psi (air) 0/300 psi (air, water, air/water) Working Pressure Steady: 3/4 of full scale value Fluctuating: 1/2 of full scale value Short time: full scale value Operating Temperature Ambient: -40°F to 140°F (-40°C to 60°C) Media: 140°F (+60°C) maximum Temperature Error Additional error when temperature changes from reference temperature of 68°F (20°C) +0.4% for every 18°F (10°C) rising or falling. Percentage of span. WWW.FPPI.COM Sprinkler Gauge Applications • Fire sprinkler systems • Suitable for all media that will not obstruct the pressure system or attack copper alloy parts Special Features • UL-listed (UL-393), United States and Canada (Sprinkler Gauge Model 111.10SP, UL Listed file EX5232) • Factory Mutual (FM) approved • Reliable and economical Description FPPI pressure gauges feature an impact and corrosion resistant case made from ABS (plastic). Features phosphor bronze bourdon tube movement with white enameled brass dial face with large numbers for easy reading. Dual scale to 300 PSI/2000Kpa. UL/ULc Listed (Sprinkler Gauge Model 111.10SP, UL Listed file EX5232) and FM Approved. 1/223 1/223 Specifications Material: Painted Plain Steel Finish: Red enamel Styles: 3 Spare sprinklers, 1/2 or 3/4 6 Spare sprinklers, 1/2 or 3/4 6 Spare, ESFR, 1/2, 3/4 or 1” 12 Spare sprinklers 1/2 or 3/4 24 Spare sprinklers 36 Spare sprinklers 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1 760 599-1168 + 1 800 344-1822 FAX + 1 800 344-3775 © 2012 Fire Protection Products, Inc. Description Fire Protection Products, Inc. Spare Sprinkler Head Cabinets are designed to allow for spare sprinkler head storage as required by NFPA guidelines. The Spare Sprinkler Head Cabinets are available in six configurations. Three head, six head, six head ESFR, twelve head, twenty-four head and thirty-six head. All six styles are manufactured with “knockouts” to accommodate the most common size sprinklers. The shelf is located to allow for the storage of a typical sprinkler head wrench. Each cabinet is finished with a red enamel finish. Each spare head cabinet comes with a hinged door which remains closed to protect the spare sprinklers from the elements and features two holes on the back panel to allow for attachment to most surfaces utilizing the appropriate fasteners. Not intended for exposed or harsh environments. WWW.FPPI.COM Spare Sprinkler Head Storage Cabinet Installation Select the correct Spare Sprinkler Head Cabinet in accordance with the Automatic Sprinkler Systems Handbook. As per the 1989 Edition the correct number of spare sprinkler is as follows: 0-300 sprinklers, not less than 6; 300-1000, not less than 12; 1000 or more, not less than 24. Stock of spare sprinklers shall include all types and ratings installed.* Once the correct Spare Sprinkler Head Cabinet has been selected, installation is accomplished by inserting the correct fastener in each of the two holes inside the cabinet, securing the cabinet securely to the wall. The insert the correct number and type of sprinklers in accordance with the “handbook”. *Final determination is subject to approval by the AHJ. Installation Installation of aluminum signs is accomplished by several methods. The most common installation procedure is to use #16 Single Jack chain to hang the sign on the area being identified. Since all of the above mentioned signs are predrilled at all four corners, the last link of the chain can be opened and hooked through the top holes on the signs and hung on the appropriate valve or piping. The signs may also be fastened to a flat surface with fasteners appropriate to the base material. (The 9” x 7” Fire Alarm Bell sign must be drilled with a 1/4” hole if it is to be attached directly to the bell gong.) Specifications Material: .020” aluminum with removable plastic coating Sizes: 6” x 2” 4” x 6” 5” x 7” 9” x 7” 12” x 10” 8.5” x 11” 7” Round See current catalog for a full listing of all available signs. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1 760 599-1168 + 1 800 344-1822 FAX + 1 800 344-3775 © 2012 Fire Protection Products, Inc. Description Manufactured from .020” white coated aluminum. All sign types are screen printed with a fade resistant red ink. Each sign is shipped with a clear protective plastic coating which can be re- moved at time of installation. Each sign type meets or exceeds NFPA13 requirements. All signs (except 7” round) are drilled in four corners to allow for easy installation. All signs (except 7” round) may be installed with sign chain or with any fastener that is suitable for the material that the sign is being attached. The 7” round bell signs are center drilled to allow for installation directly to the bell gong assembly. Type “A” 9” x 7” Control valve signs are drilled with the same four hole pattern as Type “B” 6” x 2” signs to allow for attachment of Type “B” to Type “A”. WWW.FPPI.COM Identification Signs 1/238 Specifications Type: 2-pc Adjustable w/weep hole Standard threads: 1/2” or 3/4” IPS Material: .020” cold rolled steel Standard finishes: Chrome Brass White Off White Cup & STandard SkirT depth: Min. 2” Max. 3” Base coverage: 31/2” FluSh/SeMi-FluSh SkirTS profile: (distance from base material) Flush 0.085” (flat) Semi-flush 0.345” (angled) depth: Min. 0” Max. 11/4” Base coverage: 33/4” 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1 760 599-1168 + 1 800 344-1822 FAX + 1 800 344-3775 © 2012 Fire Protection Products, Inc. Installation Proper installation of the sprinkler escutcheon can be accomplished with tools ordinarily found on the job site. The installer must make sure that the reducing coupling on the drop nipple does not exceed 2” outside diameter. The face of the coupling must extend at least 1.85” but not more than 2.85” past the finished ceiling if the standard skirt is used. Turn the escutcheon cup onto the sprinkler threads then install the sprinkler into the reducing coupling using the manufacturers sprinkler installation instructions. After the finished ceiling is installed, push the skirt over the cup so that it is flush against the ceiling. Upon system activation, leaks can be detected by observing accumulation of moisture at the “weep” hole. WWW.FPPI.COM 2-pc Adjustable Sprinkler Escutcheons Description The 2-pc adjustable sprinkler escutcheon (canopy) has been designed to provide an aesthetically pleasing concealment of the sprinkler piping servicing the individual sprinkler head. The standard sprinkler escutcheon (canopy) has a full 2” of field adjustment, making it possible to accommodate minor irregularities in ceiling to sprinkler head location. This assures complete concealment of the ceiling penetration allowing only the sprinkler to be exposed. Flush and Semi-flush skirts feature an adjustment range of 0-11/4”. Skirt are manufactured with two raised reliefs allowing for increased friction between the two parts when installed. This sprinkler escutcheon (canopy) is available in two standard thread sizes and four standard finishes. Special threads and finishes are available.