HomeMy WebLinkAboutF15-0053_Equipment Submittal_1439395980.pdfCORPORATION 57 HEREFORD LANE EDWARDS, CO 81632 PH: (970) 914-5014 1628 VAIL VALLEY DRIVE 1628 VAIL VALLEY DRIVE VAIL, CO 81657 EQUIPMENT SUBMITTAL 8/7/2015 Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Flat-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems Page 1 of 6 APRIL 2013 TFP443 Worldwide Contacts www.tyco-fire.com General Description The TYCO RAPID RESPONSE Series LFII Residential Flat-Plate Concealed Pendent Sprinklers (TY2524) are decora-tive, fast response, fusible solder sprin-klers designed for use in residential oc-cupancies such as homes, apartments, dormitories, and hotels. The Cover Plate/Retainer Assembly con-ceals the sprinkler operating compo-nents above the ceiling. The flat profile of the Cover Plate provides the optimum aesthetically appealing sprinkler design. Additionally, the concealed design of the Series LFII Residential Flat-Plate Con-cealed Pendent Sprinklers provides 1/2 inch (12,7 mm) vertical adjustment. This adjustment provides a measure of flex-ibility when cutting fixed sprinkler drops. The Series LFII Residential Flat-Plate Concealed Pendent Sprinklers are in-tended for use in the following systems: • wet and dry pipe residential sprin-kler systems for one- and two-fam-ily dwellings and mobile homes per NFPA 13D • wet and dry pipe residential sprin-kler systems for residential occu-pancies up to and including four sto-ries in height per NFPA 13R • wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 The Series LFII Residential Sprinklers have been designed with heat sensitiv-ity and water distribution characteristics proven to help in the control of residen- tial fires and to improve the chance for occupants to escape or be evacuated. The Series LFII Residential Flat-Plate Concealed Pendent Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap protects the sprinkler during ceiling installation or finish. After ceiling installation is com-plete, the Protective Cap is removed and the Cover Plate/Retainer Assem-bly is installed. Removing the Protec-tive Cap is required for proper sprinkler performance. Dry Pipe System ApplicationThe Series LFII Residential Flat-Plate Concealed Pendent Sprinkler offers a laboratory approved option for design-ing dry pipe residential sprinkler sys-tems, whereas, most residential sprin-klers are laboratory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Flat-Plate Con-cealed Sprinklers (TY2524) need not be increased over the number of design sprinklers (hydraulic design area) speci-fied for wet pipe sprinkler systems, as is customary for density/area sprinkler systems designed per NFPA 13, 13D, or 13R. Consequently, the Series LFII Residen-tial Flat-Plate Concealed Sprinklers (TY2524) offer the features of non-wa-ter filled pipe in addition to not having to increase the number of design sprinklers (hydraulic design area) for systems de-signed to NFPA 13, 13D, or 13R. Non-water filled pipe will permit options for areas sensitive to freezing. NOTICE The Series LFII Residential Flat-Plate Concealed Pendent Sprinklers (TY2524) described herein must be installed and maintained in compliance with this doc-ument and the applicable standards of the National Fire Protection Association, in addition to the standards of any au-thorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain-ing their fire protection system and de-vices in proper operating condition. The installing contractor or sprinkler manu-facturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY2524 IMPORTANTAlways refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal-lation of sprinkler systems and com-ponents. Improper handling and in-stallation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. TFP443Page 2 of 6 3-3/16" DIA.(81,0 mm) 1/2"NPT 2-1/2" DIA. (63,5 mm) MOUNTING SURFACE3/16"(4,8 mm) 1/8" GAP(3,2 mm) FACE OFSPRINKLERFITTING 7/8" (22,2 mm) 1-1/8" (28,6 mm) TIP DEFLECTOR INOPERATED POSITION 1/2" (12,7 mm)THREADEDADJUSTMENT SPRINKLER- SUPPORT CUP ASSEMBLY OPERATED SPRINKLER 1-7/8"±1/4"(47,6 mm±6,4 mm) SPRINKLER- SUPPORT CUP ASSEMBLY COVER- RETAINER ASSEMBLY COVER PLATE RETAINER DISPOSABLEPROTECTIVE CAP SPRINKLER/SUPPORT CUP ASSEMBLY COVER PLATE/RETAINER ASSEMBLY COVER PLATE EJECTION SPRING RETAINER WITH THREAD DIMPLES SOLDER TAB SEALINGASSEMBLY COMPRESSION SCREW DEFLECTOR(OPERATEDPOSITION) SPRINKLERWRENCHINGAREA SOLDER LINK ELEMENT LEVER DEFLECTOR CAP BODY(1/2" NPT) SADDLE SUPPORTCUP WITHROLL FORMEDTHREADS GUIDEPIN GUIDE PIN HOUSING THREAD INTO SUPPORT CUP UNTIL MOUNTING SURFACE IS FLUSH WITH CEILING WRENCHRECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 RAPID RESPONSE SERIES LFII RESIDENTIAL FLAT-PLATE (TY2524) INSTALLATION DIMENSIONS/PROTECTIVE CAP/ACTIVATED DEFLECTOR FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL FLAT-PLATE CONCEALED PENDENT SPRINKLER (TY2524) FIGURE 2 W-TYPE 18 SPRINKLER WRENCH TFP443 Page 3 of 6 Technical Data ApprovalsUL and C-UL Listed The TYCO RAPID RESPONSE Series LFII Residential Flat-Plate Concealed Pendent Sprinklers are only listed with the Series LFII Concealed Cover Plates having a factory-applied finish. For details on approvals, refer to the De-sign Criteria section. Maximum Working Pressure175 psi (12,1 bar) Discharge CoefficientK=4.9 GPM/psi1/2 (70,6 LPM/bar1/2) Temperature RatingSprinkler: 160°F (71°C) Cover Plate: 139°F (59°C) Vertical Adjustment1/2 inch (12,7 mm) FinishesRefer to the Ordering Procedure section. Physical CharacteristicsCover Plate/Retainer Assembly:Cover Plate . . . . . . . . . . . . . CopperEjection Spring ....Stainless SteelRetainer ................Brass Sprinkler/Support Cup Assembly:Body ...................Brass Cap ...................Bronze Saddle . . . . . . . . . . . . . . . . . . Brass Sealing Assembly . . . . . . .Beryllium Nickel w/ TEFLON Soldered Link Halves . . . . . . NickelLever ..................BronzeCompression Screw . . . . . . . BrassDeflector . . . . . . . . . . . . . . . BronzeGuide Pin Housing........BronzeGuide Pins .............BronzeSupport Cup . . . . . . . . . . . . . . Steel Operation When exposed to heat from a fire, the Cover Plate, which is normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup As-sembly. At this point, the Deflector, sup-ported by the Guide Pins, drops down to its operated position. The Solder Link Element of the Sprinkler/Support Cup Assembly is comprised of two link halves that are soldered togeth-er with a thin layer of solder. When the rated temperature is reached, the sol-der melts and the two link halves sepa-rate, allowing the sprinkler to activate and flow water. Design Criteria The TYCO RAPID RESPONSE Series LFII Residential Flat-Plate Concealed Pendent Sprinklers (TY2524) are UL and C-UL Listed for installation in ac-cordance with this section: Residential Sprinkler Design GuideWhen conditions exist that are outside the scope of the provided criteria, re-fer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that may be accept-able to the authority having jurisdiction. System TypePer the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 about the use of Residential Sprinklers in residential dry pipe systems. Ceiling TypesSmooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R or 13 as applicable. Hydraulic Design (NFPA 13D and 13R)For systems designed to NFPA 13D or NFPA 13R, the minimum required sprin-kler flow rate are given in Tables A and B as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the mini-mum required discharge from each of the total number of “design sprinklers” as specified in NFPA 13D or NFPA 13R. The number of “design sprinklers” spec-ified in NFPA 13D and 13R for wet pipe systems is to be applied when designing dry pipe systems. Hydraulic Design (NFPA 13)For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis-charge from each of the four sprinklers is to be the greater of the following: • The flow rates given in Tables A and B as a function of temperature rating and the maximum allowable cover-age area • A minimum discharge of 0.1 gpm/ft2. over the “design area” comprised of the four most hydraulically demand-ing sprinklers for the actual coverage areas being protected by the four sprinklers The number of “design sprinklers” specified in NFPA 13 for wet pipe sys-tems is to be applied when designing dry pipe systems. Dry Pipe System Water DeliveryWhen using the Series LFII Residential Flat-Plate Concealed Pendent Sprinklers (TY2524) in dry pipe sprinkler systems, the time for water delivery must not ex-ceed 15 seconds for the most remote operating sprinkler. Obstruction to Water Distribution.Sprinklers are to be located in accor-dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational SensitivityInstall sprinklers relative to the ceiling mounting surface as shown in Figure 3. The Series LFII Residential Flat-Plate Concealed Pendent Sprinklers must not be used in applications where the air pressure above the ceiling is greater than that below. Down drafts through the Support Cup can delay sprinkler op-eration in a fire situation. Sprinkler SpacingThe minimum spacing between sprin-klers is 8 feet (2,4 m). The maximum spacing between sprinklers cannot ex-ceed the length of the coverage area (Table A) being hydraulically calculated (e.g., a maximum of 12 feet for a 12 ft. x 12 ft. coverage area or 20 feet for a 20 ft. x 20 ft. coverage area.) TFP443Page 4 of 6 Maximum Coverage Area (a) Ft. x Ft. (m x m) Maximum Spacing Ft. (m) WET PIPE SYSTEM Minimum Flow and Residual Pressure(b, c) Ordinary Temp Rating 160°F (71°C)Deflector to Ceiling Installation Type Minimum Spacing Ft. (m) Flow GPM (L/min) Pressure PSI (bar) 12 x 12(3,7 x 3,7)12(3,7)13 (49,2)7.0 (0,48)Smooth Ceilings 7/8 to 1-1/8 inches. Beamed Ceilings per NFPA 13D 13R, or 13 Installed in beam 7/8 to 1-1/8 inches below bottom of beam Concealed 8 (2,4) 14 x 14(4,3 x 4,3)14(4,3)13 49,2)7.0 (0,48) 16 x 16(4,9 x 4,9)16(4,9)13(49,2)7.0 (0,48) 18 x 18(5,5 x 5,5)18(5,5)17 (64,3)12.0 (0,83) 20 x 20(6,1 x 6,1)20(6,1)20 (75,7)16.7 (1,15) (a) For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which Hydraulic Design section under the Design Criteria are stated. (b) The Minimum Flow requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pres- sures are calculated using the nominal K-factor. Refer to “Hydraulic Design” in the Design Criteria section for details. (c) For NFPA 13 residential applications, the greater of 0.1 gpm/ft.2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL FLAT-PLATE CONCEALED PENDENT SPRINKLER (TY2524) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA Maximum Coverage Area (a) Ft. x Ft. (m x m) Maximum Spacing Ft. (m) DRY PIPE SYSTEM Minimum Flow and Residual Pressure(b) Ordinary Temp Rating 160°F (71°C)Deflector to Ceiling Installation Type Minimum Spacing Ft. (m) Flow GPM (L/min) Pressure PSI (bar) 12 x 12(3,7 x 3,7)12(3,7)15 (56,8)9.4 (0,65)Smooth Ceilings 7/8 to 1-1/8 inches. Beamed Ceilings per NFPA 13D 13R, or 13 Installed in beam 7/8 to 1-1/8 inches below bottom of beam Concealed 8 (2,4) 14 x 14(4,3 x 4,3)14(4,3)15 (56,8)9.4 (0,65) 16 x 16(4,9 x 4,9)16(4,9)16 (60,6)10,7 (0,74) 18 x 18(5,5 x 5,5)18(5,5)17 (64,3)12.0 (0,83) 20 x 20(6,1 x 6,1)20(6,1)21 (79,5)18,4 (1,27) (a) For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which Hydraulic Design section under the Design Criteria are stated. (b) The Minimum Flow requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to “Hydraulic Design” in the Design Criteria section for details. (c) For NFPA 13 residential applications, the greater of 0.1 gpm/ft.2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM SERIES LFII RESIDENTIAL FLAT-PLATE CONCEALED PENDENT SPRINKLER (TY2524) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TFP443 Page 5 of 6 Installation The TYCO RAPID RESPONSE Series LFII Residential Flat-Plate Concealed Pendent Sprinklers must be installed in accordance with this section: General InstructionsDamage to the Solder Link Element dur-ing installation can be avoided by han-dling the sprinkler by the Support Cup only; that is, do not apply pressure to the Solder Link Element (Figure 1). A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min-imum-to-maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insuf-ficient adjustment in the Cover Plate/Retainer Assembly by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install pendent sprinklers in the pendent position, with the center-line of the sprinkler perpendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe-thread sealant ap-plied to the pipe threads, and using the W-Type 18 Wrench shown in Figure 2, install and tighten the Sprinkler/Sup-port Cup Assembly into the fitting. The W-Type 18 Wrench accepts a 1/2 inch ratchet drive. Step 4. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. The Protec-tive Cap helps prevent damage to the Deflector and Guide Pins during ceiling installation and/or during application of the finish coating of the ceiling. NOTICE As long as the protective Cap remains in place, the system is considered “Out Of Service”. Step 5. After the ceiling has been com-pleted with the 2-1/2 inch (63 mm) diam-eter hole and in preparation for install-ing the Cover Plate/Retainer Assembly, remove and discard the Protective Cap, and verify that the Deflector moves up and down freely. If the sprinkler has been damaged and the deflector does not move up and down freely, replace the entire sprinkler assembly. Do not attempt to modify or repair a damaged sprinkler. Step 6. Screw on the Cover Plate/Re-tainer Assembly until its flange contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly such that it lifts a ceiling panel out of its normal position. If the Cover Plate/Retainer Assembly cannot be engaged with the Mounting Cup or the Cover Plate/Retainer Assem-bly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. Care and Maintenance The TYCO RAPID RESPONSE Series LFII Residential Flat-Plate Concealed Pendent Sprinkler (TY2524) must be maintained and serviced in accordance with ths section: Before closing a fire protection system main control valve for maintenance work on the fire protection system that it con-trols, obtain permission to shut down the affected fire protection system from the proper authorities and notify all person-nel who may be affected by this action. Absence of a Cover Plate may delay the sprinkler operation in a fire situation. The owner must assure that the sprin-klers are not used for hanging any ob-jects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non-opera-tion in the event of a fire or inadvertent operation may result. When properly installed, there is a nomi-nal 1/8 inch (3,2 mm) air gap between the lip of the Cover Plate and the ceil-ing, as shown in Figure 3. This air gap is necessary for proper operation of the sprinkler by allowing heat flow from a fire to pass below and above the Cover Plate to help assure appropriate release of the Cover Plate in a fire situation. If the ceiling needs repainting after sprinkler installation, exercise care to ensure that the new paint does not seal off any of the air gap. Failure to do so may impair sprinkler operation. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted units. Non-factory applied paint may adversely delay or prevent sprinkler operation in the event of a fire. Do not pull the Cover Plate relative to the Retainer. Separation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi-fied or overheated sprinklers must be replaced. Care must be exercised to avoid dam-age to the sprinklers - before, during, and after installation. Sprinklers dam-aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. The owner is responsible for the in-spection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the stan-dards of any other authorities having ju-risdiction. Contact the installing contrac-tor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec-ommended to be inspected, tested, and maintained by a qualified Inspec-tion Service in accordance with local requirements and/or national codes. A H E A D O F T H E F L O W ® www.nibco.com NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 4 All of the advantages found in copper as a metal have been capitalized to the utmost in the manufacture of NIBCO Fittings. Because of the accuracy of construc tion and design, copper plumbing is more efficient and less expensive. NIBCO manufactures nine general types of fittings: Wrot Pressure; Cast Pressure; Wrot Drainage; Cast Drainage; Flanges; Flared Tube; Threaded Bronze; Insert Fittings for PEX; Barbed Insert Fittings for Polybutylene. Each has its particular place and use and each offers its own advantages when used for the proper service requirement. ALLOY AND FINISH — NIBCO Fittings are made from highest quality raw materials available — Cast Fittings are made from Copper Alloy C84400 which consists of 81% Copper, 7% Lead, 3% Tin, and 9% Zinc per ASTM Specification B584. Wrot Copper Fittings are made from commercially pure copper mill products per ASTM Specifications B75 Alloy C12200. NIBCO fittings are produced to meet requirements of applicable standards wherever practicable. NIBCO brand wrot and cast fittings are manufactured in the U.S.A. and Mexico. The manufacturing plants at Stuarts Draft, VA, Nacogdoches, TX and Reynosa, Mexico are registered to ISO 9002 quality standards. Following is suggested phrasing to be incorporated in your specifications or bills of material for Copper Tube Fittings. WROT SOLDER JOINT FITTINGS — “Wrot Solder Joint Fittings shall be produced to one of the following specifications: 1. Material and workmanship shall be in accordance with ASME/ANSI B16.22; Wrought Copper and Copper Alloy Solder Joint Pressure Fittings.” Specifications 2. The dimensional, material and workmanship shall meet the requirements of MSS SP-104; Wrought Copper Solder Joint Pressure Fittings.” 3. The dimensional, material and workmanship of 5"–12" copper fittings shall meet the requirements of MSS SP-109 “Welded Fabricated Copper Solder Joint Pressure Fittings.” 4. Certified to ANSI/NSF 61. CAST COPPER ALLOY SOLDER JOINT FITTINGS — “Cast Copper Alloy Solder Joint Fittings shall be in accor dance with ANSI Std. B16.18.” WROT DRAINAGE FITTINGS — “Wrot Drainage Fittings shall be in accordance with ASME/ANSI Std. B16.29.” CAST COPPER ALLOY SOLDER JOINT DRAINAGE FITTINGS — “Cast Copper Alloy Solder Joint Drainage Fittings shall be in accordance with ASME Std. B16.23.” CAST COPPER ALLOY FLARED TUBE FITTINGS — “Cast Copper Alloy Flared Tube Fittings shall be in accor- dance with ASME/ANSI Std. B16.26. CAST COPPER ALLOY FLANGES AND FLANGED FITTINGS— CLASS 150 — Cast Copper Alloy Flanges and Flanged Fittings shall meet the requirements of MSS SP-106 and/or the workmanship and dimensions of Federal Specifications WW-F-406 or ASME Std. B16.24. CLASS 125 — Material, workmanship and dimensions of flanges shall be in accordance with MSS SP-106. CAST BRONZE THREADED FITTINGS — “Cast Bronze Threaded Fittings shall be in accordance with ANSI/ASME B16.15.” POLYBUTYLENE COPPER INSERT TYPE VALVES AND FITTINGS — “Wrot Copper Insert Fittings shall be manufactured per the following specifications: MSS SP-103 or ASTM F1380.” NIBCO Copper Tube Fittings are all produced to above Standards. To simplify, write your specifications to read: “Copper Tube Fittings to be in accordance with specifications as outlined in NIBCO Catalog c-cf-0602.” WROT COPPER MEDICAL MEDICAL GAS SYSTEM COMPONENTS — Wrot copper fittings that are to be installed in medical gas applications shall be prepared in accordance with NFPA 99, Health Care Facilities Gas and Vacuum Systems and the Compressed Gas Association, Pamphlet G4.1. Packaging shall be adequately protective and include labeling that identifies the preparer and states that the product has been cleaned and bagged for oxygen or med gas service. For technical information and dimensions refer to the engineering section contained in this catalog. Revision 3/29/04 A H E A D O F T H E F L O W ® www.nibco.com NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 6 703-2 Fitting Adapter Ftg x F – Cast APPROX. DIM. B NOM. SIZE NET WT./LBS. INCHES 1/2 x 1/4 0.11 17/32 3/4 x 1/2 0.12 19/16 1 x 3/4 0.38 131/32 1 x 1/2 0.15 17/16 2 1/2 1.65 215/16 3 2.47 31/4 703-5 Special Drop Adapter C x F – Cast APPROX. DIM. A NOM. SIZE NET WT./LBS. INCHES 1/2 0.16 3/4 3/4 0.24 31/32 703-5B Drop Adapter C x F – Cast APPROX. DIM. A NOM. SIZE NET WT./LBS. INCHES 1/2 0.15 3/4 ADAPTERS 603 Adapter C x F – Wrot APPROX. DIM. A NOM. SIZE NET WT./LBS. INCHES 1/8 0.03 13/32 1/8 x 1/4 0.03 1/2 1/4 0.03 5/8 1/4 x 3/8 0.05 21/32 3/8 0.04 11/16 3/8 x 1/2 0.09 29/32 3/8 x 1/4 0.03 9/16 1/2 0.09 27/32 1/2 x 3/4 0.14 1 1/2 x 3/8 0.04 17/32 1/2 x 1/4 0.05 1/2 5/8 x 3/4 0.12 29/32 5/8 x 1/2 0.11 3/4 3/4 0.15 29/32 3/4 x 1 0.21 11/8 3/4 x 1/2 0.10 5/8 1 0.24 31/32 1 x 1 1/4 0.28 17/32 1 x 3/4 0.19 25/32 1 x 1/2 0.24 5/8 1 1/4 0.33 13/32 1 1/4 x 1 1/2 0.40 11/4 1 1/4 x 1 0.27 31/32 1 1/2 0.44 11/8 1 1/2 x 2 0.50 11/32 2 0.63 13/32 2 x 1 1/2 0.74 13/16 2 1/2 1.13 – 3 1.94 – 703 Adapter C x F – Cast APPROX. DIM. A NOM. SIZE NET WT./LBS. INCHES 1/4 x 1/2 0.13 27/32 1/2 x 1 0.30 1 3/4 x 1 1/4 0.55 11/8 3/4 x 3/8 0.17 3/4 1 x 1 1/2 0.68 13/32 1 1/4 x 1 0.27 31/32 1 1/4 x 3/4 0.29 3/4 1 1/2 x 2 0.78 11/32 1 1/2 x 1 0.37 25/32 1 1/2 x 1 1/4 0.47 11/4 2 x 1 1/4 0.76 27/32 2 1/2 1.62 13/8 3 2.34 11/2 4 4.05 19/16 603-2Fitting Adapter Ftg x F – Wrot APPROX. DIM. B NOM. SIZE NET WT./LBS. INCHES 1/4 0.03 13/32 3/8 0.06 13/16 1/2 0.09 17/16 1/2 x 3/8 0.05 11/4 3/4 0.13 111/16 1 0.27 21/32 1 1/4 0.31 21/8 1 1/2 0.43 25/16 2 0.61 217/32 Consult price sheet for Made to Order items and for minimum order quantities. Revision 2/6/07 A H E A D O F T H E F L O W ® www.nibco.com NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 9 Consult price sheet for Made to Order items and for minimum order quantities. CAPS 617 Tube Cap C – Wrot APPROX. DIM. N NOM. SIZE NET WT./LBS. INCHES 1/8 0.01 1/32 1/4 0.01 3/32 3/8 0.01 3/32 1/2 0.02 3/32 5/8 0.03 1/8 3/4 0.04 1/8 1 0.07 5/32 1 1/4 0.10 3/32 1 1/2 0.16 1/8 2 0.27 5/32 2 1/2 0.50 7/32 3 0.78 7/32 4 1.66 1/4 717 Tube Cap C – Cast APPROX. DIM. N NOM. SIZE NET WT./LBS. INCHES 5 5.48 7/16 6 9.07 17/32 717-D Drain Cap – Cast APPROX. DIM. A NOM. SIZE NET WT./LBS. INCHES 1/2 0.06 21/32 COUPLINGS 600 Reducing Coupling C x C – Wrot APPROX. DIM. A NOM. SIZE NET WT./LBS. INCHES 1/8 x 3/16 O.D. 0.01 5/32 5/16 O.D. x 1/8 0.01 3/16 1/4 x 5/16 O.D. 0.01 3/16 1/4 x 1/8 0.01 3/16 3/8 x 1/4 0.02 3/16 3/8 x 5/16 O.D. 0.01 1/4 3/8 x 1/8 0.01 1/4 1/2 x 3/8 0.03 3/16 1/2 x 1/4 0.02 1/4 1/2 x 1/8 0.03 11/32 5/8 x 1/2 0.05 3/16 5/8 x 3/8 0.04 11/32 5/8 x 1/4 0.03 13/32 3/4 x 5/8 0.07 3/16 3/4 x 1/2 0.06 9/32 3/4 x 3/8 0.06 3/8 3/4 x 1/4 0.05 11/32 1 x 3/4 0.11 11/32 1 x 5/8 0.09 3/8 1 x 1/2 0.10 11/32 1 x 3/8 0.10 13/32 1 1/4 x 1 0.16 5/16 1 1/4 x 3/4 0.18 17/32 1 1/4 x 5/8 0.18 5/8 1 1/4 x 1/2 0.14 7/16 1 1/2 x 1 1/4 0.23 5/16 1 1/2 x 1 0.22 9/16 1 1/2 x 3/4 0.20 3/8 1 1/2 x 1/2 0.19 1/2 2 x 1 1/2 0.41 9/16 2 x 1 1/4 0.35 11/16 2 x 1 0.37 7/16 2 x 3/4 0.34 17/32 2 x 1/2 0.35 23/32 2 1/2 x 2 0.59 9/16 2 1/2 x 1 1/2 0.65 11/16 2 1/2 x 1 1/4 0.65 13/16 2 1/2 x 1 0.73 29/32 Continues… APPROX. DIM. A NOM. SIZE NET WT./LBS. INCHES 3 x 2 1/2 0.98 1/2 3 x 2 1.06 15/16 3 x 1 1/2 0.92 11/32 3 1/2 x 3 1.52 1/2 4 x 3 1/2 2.12 19/32 4 x 3 1.92 27/32 4 x 2 1/2 1.77 1 4 x 2 1.92 11/4 5 x 4 3.50 331/32 5 x 3 3.18 115/32 5 x 2 1/2 3.50 13/16 5 x 2 3.09 21/32 6 x 5 5.70 11/8 6 x 4 5.24 11/2 6 x 3 5.04 2 6 x 2 1/2 5.13 21/4 6 x 2 4.89 21/2 8 x 6 13.06 119/32 8 x 4 12.22 219/32 8 x 3 11.79 33/32 8 x 2 1/2 12.64 33/8 600-RS Coupling with Rolled Tube Stop C x C – Wrot APPROX. DIM. A NOM. SIZE NET WT./LBS. INCHES 1/8 O.D. 0.01 1/16 3/16 O.D. 0.01 3/32 1/8 0.01 1/16 5/16 O.D. 0.01 3/32 1/4 0.01 1/16 3/8 0.01 3/32 1/2 0.03 3/32 5/8 0.04 3/32 3/4 0.06 3/32 7/8 0.09 3/32 1 0.11 3/32 1 1/4 0.16 1/8 1 1/2 0.23 1/8 2 0.41 1/8 2 1/2 0.65 1/8 3 0.93 1/8 3 1/2 1.45 5/32 4 1.93 7/32 Revision 2/6/07 A H E A D O F T H E F L O W ® www.nibco.com NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 12 ELBOWS continued Consult price sheet for Made to Order items and for minimum order quantities. 706-2 45° Fitting Elbow Ftg x C – Cast APPROX. DIM. B DIM. C NOM. SIZE NET WT./LBS. INCHES INCHES 4 4.31 311/32 15/16 607 90° Elbow – Close Rough C x C – Wrot APPROX. DIM. C DIM. D NOM. SIZE NET WT./LBS. INCHES INCHES 1/8 0.01 13/32 13/32 1/4 0.02 9/32 9/32 3/8 0.03 1/2 1/2 1/2 0.04 3/8 3/8 1/2 x 3/8 0.04 9/16 21/32 3/4 0.10 17/32 17/32 3/4 x 5/8 0.12 29/32 7/8 3/4 x 1/2 0.10 17/32 3/4 1 0.21 23/32 23/32 1 x 3/4 0.16 23/32 5/8 1 1/4 0.31 11/32 11/32 1 1/4 x 1 0.31 15/8 115/32 1 1/2 0.46 17/32 17/32 1 1/2 x 1 1/4 0.35 15/32 13/32 2 0.84 11/2 11/2 2 x 1 1/2 0.58 17/16 11/4 2 1/2 1.41 127/32 127/32 3 2.07 23/32 23/32 3 1/2 2.94 23/8 23/8 4 4.23 225/32 225/32 5 7.74 27/8 27/8 6 10.95 37/16 37/16 8 29.50 423/32 423/32 707 90° Elbow – Close Rough C x C – Cast APPROX. DIM. C DIM. D NOM. SIZE NET WT./LBS. INCHES INCHES 1 1/4 x 1 0.42 15/8 115/32 1 1/4 x 3/4 0.34 9/16 13/16 1 1/4 x 1/2 0.28 15/32 27/32 1 1/2 x 1 0.54 11/16 1 1 1/2 x 3/4 0.42 19/32 31/32 1 1/2 x 1/2 0.40 5/8 29/32 2 x 1 1/4 0.86 7/8 11/4 2 x 1 0.78 3/4 11/4 2 x 3/4 0.69 5/8 11/4 2 1/2 x 2 2.16 13/16 19/32 3 x 2 1/2 2.26 111/16 11/2 3 x 2 2.68 13/8 19/16 4 x 3 5.18 129/32 215/32 607-I 90° Elbow – Intermediate Radius C x C – Wrot APPROX. DIM. C DIM. D NOM. SIZE NET WT./LBS. INCHES INCHES 1/2 0.06 19/32 19/32 5/8 0.09 7/8 7/8 3/4 0.14 13/16 3/16 1 0.24 11/16 11/16 607-LT 90° Elbow – Long Radius C x C – Wrot APPROX. DIM. C DIM. D NOM. SIZE NET WT./LBS. INCHES INCHES 3/16 O.D. 0.01 13/32 13/32 1/8 0.01 13/32 13/32 5/16 O.D. 0.02 9/16 9/16 1/4 0.02 17/32 17/32 1/4 x 1/8 0.01 19/32 1/2 3/8 0.04 23/32 23/32 1/2 0.08 7/8 7/8 1/2 x 3/8 0.06 13/16 13/16 1/2 x 1/4 0.03 25/32 21/32 5/8 0.10 13/32 13/32 5/8 x 1/2 0.09 11/16 11/16 3/4 0.16 11/8 11/8 3/4 x 5/8 0.13 11/4 13/32 3/4 x 1/2 0.10 11/8 11/16 7/8 0.28 119/32 119/32 1 0.28 17/16 17/16 1 x 3/4 0.20 11/4 11/8 1 x 5/8 0.15 113/32 13/32 1 1/4 0.42 17/8 17/8 1 1/4 x 1 0.33 125/32 11/2 1 1/2 0.66 21/4 21/4 2 1.23 215/16 215/16 2 1/2 1.96 311/16 311/16 3 2.93 41/32 41/32 4 5.95 51/4 51/4 Revision 2/7/07 A H E A D O F T H E F L O W ® www.nibco.com NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 15 707-6 90° Union Elbow C x C – Cast APPROX. DIM. A DIM. C NOM. SIZE NET WT./LBS. INCHES INCHES 3/8 0.17 31/32 5/16 1/2 0.24 1 7/16 3/4 0.39 117/32 9/16 1 0.64 121/32 23/32 1 1/4 1.07 119/32 23/32 708 90° Flanged Sink Elbow C x F – Cast NOM. APPROX. DIM. A DIM. C DIM. F SIZE NET WT./LBS. INCHES INCHES INCHES 1/2 0.20 7/8 9/16 13/4 764 90° Double Elbow C x C x C – Cast APPROX. DIM. C DIM. D NOM. SIZE NET WT./LBS. INCHES INCHES 1 x 3/4 x 3/4 0.33 3/4 21/32 ELBOWS continued Consult price sheet for Made to Order items and for minimum order quantities. FITTING REDUCERS APPROX. DIM. B NOM. SIZE NET WT./LBS. INCHES 4 x 3 1/2 2.09 25/8 4 x 3 2.00 31/32 4 x 2 1/2 1.56 31/32 4 x 2 1.76 313/32 5 x 4 3.30 39/16 5 x 3 2.97 41/16 5 x 2 1/2 3.30 411/32 5 x 2 2.88 411/16 6 x 5 5.56 43/16 6 x 4 5.09 49/16 6 x 3 4.67 51/16 6 x 2 1/2 4.47 511/32 6 x 2 4.51 519/32 8 x 6 12.33 515/32 8 x 5 10.35 515/16 8 x 4 11.10 67/16 8 x 3 10.63 615/16 8 x 2 1/2 11.41 73/16 8 x 2 10.86 77/16 741 Companion Flange C – Cast NOM. APPROX. DIM. B DIM. F DIM. G DIM. W SIZE NET WT./LBS. INCHES INCHES INCHES INCHES 1/2 0.55 1/8 31/2 3/16 23/8 3/4 0.71 1/8 37/8 3/16 23/4 1 1.26 1/8 41/4 1/4 31/8 1 1/4 1.42 1/8 45/8 1/4 31/2 1 1/2 1.82 1/8 5 5/16 37/8 2 2.76 1/8 6 3/8 43/4 2 1/2 4.29 1/8 7 3/8 51/2 3 5.26 1/8 71/2 7/16 6 4 7.60 1/8 9 7/16 71/2 5 9.04 1/8 10 7/16 81/2 6 12.68 1/8 11 1/2 91/2 NOTE: Dim. B = Tube Stop to Flange Face 600-2 Fitting Reducer Ftg x C – Wrot APPROX. DIM. B NOM. SIZE NET WT./LBS. INCHES 1/4 x 1/8 0.01 15/32 3/8 x 1/4 0.01 19/32 3/8 x 1/8 0.01 25/32 1/2 x 3/8 0.03 11/16 1/2 x 1/4 0.02 25/32 5/8 x 1/2 0.04 7/8 5/8 x 3/8 0.04 31/32 5/8 x 1/4 0.03 11/32 3/4 x 5/8 0.06 31/32 3/4 x 1/2 0.06 11/8 3/4 x 3/8 0.05 11/8 3/4 x 1/4 0.05 13/32 1 x 3/4 0.10 17/32 1 x 5/8 0.09 13/8 1 x 1/2 0.09 11/4 1 x 3/8 0.08 19/32 1 1/4 x 1 0.15 15/16 1 1/4 x 3/4 0.16 11/2 1 1/4 x 1/2 0.13 13/8 1 1/2 x 1 1/4 0.23 113/32 1 1/2 x 1 0.21 15/8 1 1/2 x 3/4 0.20 17/8 1 1/2 x 1/2 0.16 119/32 2 x 1 1/2 0.40 131/32 2 x 1 1/4 0.34 23/32 2 x 1 0.35 127/32 2 x 3/4 0.35 127/32 2 x 1/2 0.34 131/32 2 1/2 x 2 0.65 131/32 2 1/2 x 1 1/2 0.65 23/8 2 1/2 x 1 1/4 0.60 27/32 2 1/2 x 1 0.78 29/32 3 x 2 1/2 1.03 21/4 3 x 2 0.99 29/16 3 x 1 1/2 0.81 219/32 3 x 1 1/4 1.29 31/4 3 1/2 x 3 1.48 211/32 Continues… FLANGES – CLASS 125 Revision 2/8/07 A H E A D O F T H E F L O W ® www.nibco.com NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 18 APPROX. DIMENSIONS NET WT. INCHES NOM. SIZE LBS. C F G 1 x 1/2 x 1 0.29 11/16 1 21/32 1 x 1/2 x 3/4 0.27 9/16 13/16 3/4 1 x 1/2 x 1/2 0.22 15/32 25/32 23/32 1 1/4 0.43 13/16 3/16 13/16 1 1/4 x 1 1/4 x 2 1.13 130/32 130/32 13/32 1 1/4 x 1 1/4 x 1 1/2 0.60 13/16 13/16 29/32 1 1/4 x 1 1/4 x 1 0.45 25/32 25/32 29/32 1 1/4 x 1 1/4 x 3/4 0.37 21/32 21/32 3/4 1 1/4 x 1 1/4 x 1/2 0.30 1/2 1/2 25/32 1 1/4 x 1 1/4 x 3/8 0.34 23/32 23/32 29/32 1 1/4 x 1 x 1 1/4 0.43 13/16 11/32 13/16 1 1/4 x 1 x 1 0.47 25/32 7/8 29/32 1 1/4 x 1 x 3/4 0.35 21/32 25/32 7/8 1 1/4 x 1 x 1/2 0.30 1/2 5/8 29/32 1 1/4 x 3/4 x 1 1/4 0.42 13/16 11/8 13/16 1 1/4 x 3/4 x 1 0.45 25/32 11/32 29/32 1 1/4 x 3/4 x 3/4 0.37 21/32 15/16 7/8 1 1/4 x 3/4 x 1/2 0.30 1/2 3/4 29/32 1 1/4 x 1/2 x 1 1/4 0.41 13/16 17/32 13/16 1 1/2 0.61 31/32 31/32 29/32 1 1/2 x 1 1/2 x 2 1.11 125/32 125/32 13/32 1 1/2 x 1 1/2 x 1 1/4 0.62 29/32 29/32 11/16 1 1/2 x 1 1/2 x 1 0.55 11/16 11/16 7/8 1 1/2 x 1 1/2 x 3/4 0.45 11/16 11/16 11/32 1 1/2 x 1 1/2 x 1/2 0.40 1/2 1/2 11/32 1 1/2 x 1 1/4 x 1 1/2 0.62 11/32 13/16 29/32 1 1/2 x 1 1/4 x 1 1/4 0.62 31/32 13/32 31/32 1 1/2 x 1 1/4 x 1 0.51 25/32 1 11/32 1 1/2 x 1 1/4 x 3/4 0.49 11/16 13/16 11/32 1 1/2 x 1 1/4 x 1/2 0.41 1/2 25/32 11/32 1 1/2 x 1 x 1 1/2 0.59 11/32 111/32 29/32 1 1/2 x 1 x 1 1/4 0.63 29/32 11/8 11/16 1 1/2 x 1 x 1 0.54 25/32 11/16 11/32 1 1/2 x 1 x 3/4 0.44 11/16 31/32 15/16 1 1/2 x 1 x 1/2 0.39 1/2 25/32 11/32 1 1/2 x 3/4 x 1 1/2 0.62 11/32 17/16 11/16 1 1/2 x 3/4 x 1 1/4 0.58 29/32 111/32 11/16 1 1/2 x 3/4 x 1 0.54 25/32 11/4 11/32 1 1/2 x 3/4 x 3/4 0.47 11/16 13/32 29/32 1 1/2 x 3/4 x 1/2 0.39 1/2 29/32 31/32 1 1/2 x 1/2 x 1 1/2 0.62 11/32 113/32 31/32 Continues… APPROX. DIMENSIONS NET WT. INCHES NOM. SIZE LBS. C F G 2 1.30 19/32 19/32 11/32 2 x 2 x 2 1/2 2.34 2 2 121/32 2 x 2 x 1 1/2 1.17 11/4 11/4 123/32 2 x 2 x 1 1/4 1.12 9/32 9/32 17/8 2 x 2 x 1 0.90 27/32 27/32 11/4 2 x 2 x 3/4 0.88 19/32 19/32 11/4 2 x 2 x 1/2 1.17 11/4 11/4 21/4 2 x 1 1/2 x 2 1.16 19/32 17/8 111/32 2 x 1 1/2 x 1 1/2 1.15 11/4 13/4 123/32 2 x 1 1/2 x 1 1/4 1.15 7/32 13/4 111/32 2 x 1 1/2 x 3/4 0.83 21/32 15/16 17/32 2 x 1 1/2 x 1/2 1.12 11/4 125/32 21/4 2 x 1 1/4 x 2 1.58 19/32 115/32 19/32 2 x 1 1/4 x 1 1/2 1.16 11/4 131/32 123/32 2 x 1 1/4 x 1 1/4 1.19 15/16 111/32 111/32 2 x 1 1/4 x 1 0.90 27/32 19/32 111/32 2 x 1 1/4 x 3/4 0.85 21/32 1 18/27 2 x 1 x 2 1.11 11/8 125/32 11/4 2 x 1 x 1 0.89 27/32 19/32 111/32 2 x 3/4 x 2 1.15 19/32 23/16 11/4 2 x 1/2 x 2 1.15 19/32 23/8 11/4 2 1/2 2.40 15/8 15/8 15/8 2 1/2 x 2 1/2 x 2 1.97 15/16 15/16 121/32 2 1/2 x 2 1/2 x 1 1/2 1.53 13/32 13/32 121/32 2 1/2 x 2 1/2 x 1 1/4 1.72 13/32 13/32 127/32 2 1/2 x 2 1/2 x 1 1.34 25/32 25/32 111/16 2 1/2 x 2 1/2 x 3/4 1.34 25/32 25/32 113/16 2 1/2 x 2 1/2 x 1/2 1.34 25/32 25/32 21/8 2 1/2 x 2 x 2 1/2 1.99 121/32 23/32 121/32 2 1/2 x 2 x 2 1.95 111/32 15/8 123/32 2 1/2 x 2 x 1 1/2 1.57 13/32 213/32 121/32 2 1/2 x 2 x 1 1/4 1.57 13/32 119/32 127/32 2 1/2 x 2 x 1 1.40 25/32 19/32 13/4 2 1/2 x 2 x 3/4 1.35 25/32 19/32 127/32 2 1/2 x 1 1/2 x 1 1/2 1.76 13/32 113/32 13/8 2 1/2 x 1 1/4 x 2 1/2 2.40 121/32 27/16 121/32 2 1/2 x 1 x 2 1/2 2.04 121/32 223/32 121/32 2 1/2 x 3/4 x 2 1/2 2.00 121/32 211/16 121/32 2 1/2 x 1/2 x 2 1/2 2.46 11/2 27/32 11/2 Continues… APPROX. DIMENSIONS NET WT. INCHES NOM. SIZE LBS. C F G 3 3.15 17/8 17/8 21/32 3 x 3 x 2 1/2 3.55 129/32 129/32 23/8 3 x 3 x 2 3.19 115/32 115/32 131/32 3 x 3 x 1 1/2 3.08 115/32 115/32 29/32 3 x 3 x 1 1/4 3.10 115/32 115/32 27/16 3 x 3 x 1 2.12 27/32 27/32 131/32 3 x 3 x 3/4 2.39 27/32 27/32 23/16 3 x 3 x 1/2 1.82 27/32 27/32 23/8 3 x 2 1/2 x 3 3.08 17/8 23/8 131/32 3 x 2 1/2 x 2 1/2 3.12 129/32 211/32 25/32 3 x 2 1/2 x 2 2.28 115/32 127/32 131/32 3 x 2 x 3 3.62 129/32 217/32 115/16 3 x 2 x 2 1/2 3.56 129/32 29/16 25/16 3 x 2 x 2 3.22 115/32 131/32 131/32 3 x 1 1/2 x 3 3.13 129/32 225/32 23/32 3 x 1 1/4 x 3 3.63 129/32 225/32 115/16 3 x 1 x 3 3.20 131/32 219/32 23/16 3 x 3/4 x 3 3.55 131/32 229/32 23/16 3 1/2 5.20 217/32 217/32 217/32 4 8.12 213/32 213/32 217/32 4 x 4 x 3 6.70 21/32 21/32 221/32 4 x 4 x 2 1/2 6.65 21/32 21/32 35/32 4 x 4 x 2 5.82 115/32 115/32 27/16 4 x 4 x 1 1/2 3.94 111/32 111/32 217/32 4 x 4 x 1 1/4 4.04 111/32 111/32 229/32 4 x 4 x 1 3.72 1 1 29/16 4 x 4 x 3/4 3.70 1 1 211/16 4 x 3 x 4 7.05 225/32 37/32 217/32 4 x 3 x 3 5.03 21/32 215/32 215/32 4 x 3 x 2 1/2 5.04 21/32 215/32 229/32 4 x 3 x 2 5.87 115/32 131/32 27/16 4 x 2 1/2 x 4 7.19 225/32 315/32 227/32 4 x 2 x 4 7.08 225/32 319/32 227/32 Continued on next page. NOTE: Tee sizes are read Run x Run x Outlet. 611 Tee C x C x C – Wrot continued TEES continued Consult price sheet for Made to Order items and for minimum order quantities. Revision 2/8/07 A H E A D O F T H E F L O W ® www.nibco.com NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 49 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. Copper Water Tube continued DIMENSIONAL DATA – COPPER WATER TUBE – TYPE “M” TYPE “M” Hard Drawn Only: 20-ft. (6.1m) Straight Lengths Usage: For general purpose plumbing, heating and drainage installations. Tolerances Hard Drawn (Hard Drawn Only) Outside Tubing OD Nominal Wall Weight Bursting Safe Working Nominal Diameter Thickness Per Foot PressureA PressureB Water Tube Min. Max. Size (In Inches) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Lb (kg) psi (bars) psi (bars) 1/4 0.375 (9.53) 0.373 (9.47) 0.376 (9.55) N/A N/A N/A N/A N/A N/A N/A N/A 3/8 0.500 (12.70) 0.497 (12.62) 0.501 (12.73) 0.025 (0.64) 0.145 (0.07) N/A N/A 855 (59) 1/2 0.625 (15.88) 0.622 (15.80) 0.626 (15.90) 0.028 (0.71) 0.204 (0.09) 6135 (423) 741 (51) 5/8 0.750 (19.05) 0.747 (18.97) 0.751 (19.08) N/A N/A N/A N/A N/A N/A N/A N/A 3/4 0.875 (22.23) 0.872 (22.15) 0.876 (22.25) 0.032 (0.81) 0.328 (0.15) 4717 (325) 611 (42) 1 1.125 (28.58) 1.122 (28.50) 1.127 (28.63) 0.035 (0.89) 0.465 (0.21) 3865 (266) 506 (35) 1 1/4 1.375 (34.93) 1.372 (34.85) 1.377 (34.98) 0.042 (1.07) 0.682 (0.31) 3875 (267) 507 (35) 1 1/2 1.625 (41.28) 1.621 (41.17) 1.627 (41.33) 0.049 (1.24) 0.940 (0.43) 3550 (245) 497 (34) 2 2.125 (53.98) 2.121 (53.87) 2.127 (54.03) 0.058 (1.47) 1.460 (0.66) 2935 (202) 448 (31) 2 1/2 2.625 (66.68) 2.621 (66.57) 2.627 (66.73) 0.065 (1.65) 2.030 (0.92) 2800 (193) 411 (28) 3 3.125 (79.38) 3.121 (79.27) 3.127 (79.43) 0.072 (1.83) 2.680 (1.22) 2665 (184) 380 (26) 3 1/2 3.625 (92.08) 3.621 (91.97) 3.627 (92.13) 0.083 (2.11) 3.580 (1.62) N/A N/A 378 (26) 4 4.125 (104.78) 4.121 (104.67) 4.127 (104.83) 0.095 (2.41) 4.660 (2.11) 2215 (153) 377 (26) 5 5.125 (130.18) 5.121 (130.07) 5.127 (130.23) 0.109 (2.77) 6.660 (3.02) 2490 (172) 349 (24) 6 6.125 (155.58) 6.121 (155.47) 6.127 (155.63) 0.122 (3.10) 8.920 (4.05) 2000 (138) 328 (23) 8 8.125 (206.38) 8.119 (206.22) 8.127 (206.43) 0.170 (4.32) 16.500 (7.48) 2285 (158) 344 (24) 10 10.125 (257.18) 10.119 (257.02) 10.127 (257.23) 0.212 (5.38) 25.600 (11.61) N/A N/A 344 (24) 12 12.125 (307.98) 12.119 (307.82) 12.127 (308.03) 0.254 (6.45) 36.700 (16.65) N/A N/A 345 (24) Note: Information and data contained in these charts, as taken from ASTM Specifications B 88. Rated internal pressure for copper water tube based on the strength of the tube alone and applicable to systems using suitable mechanical joints. A Based on actual laboratory test data provided by Copper Development Association, Inc. B Based upon 150°F (65.6°C) with an allowable stress of 9500 psi (668 kPa). Revision 5/12/02 A H E A D O F T H E F L O W ® www.nibco.com NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 62 1" TYPE “M” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D. = 1.1265 inches (28.613 mm) Nominal O.D. = 1.1250 inches (28.575 mm) Minimum O.D. = 1.1235 inches (28.537 mm) Nominal I.D. = 1.0558 inches (26.797 mm) Nominal Wall Thickness = 0.0350 inches (0.889 mm) Flow Area = 0.8742 sq. inches (563.98 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q Pressure Loss Head Loss Velocity FLOW, Q Pressure Loss Head Loss Velocity (GPM) (psi/100 ft) (ft/100 ft) (ft./sec.) (cu. cm/sec.) (kPa/100 m) (m/100 m) (m/sec.) 2.50 0.18 0.41 0.92 158 0.04 0.41 0.28 5.00 0.64 1.49 1.84 315 0.14 1.49 0.56 7.50 1.36 3.15 2.75 473 0.31 3.15 0.84 10.00 2.31 5.37 3.67 631 0.52 5.37 1.12 12.50 3.49 8.11 4.59 789 0.79 8.11 1.40 15.00 4.90 11.36 5.51 946 1.11 11.36 1.68 17.50 6.52 15.11 6.42 1104 1.47 15.11 1.96 20.00 8.34 19.35 7.34 1262 1.89 19.35 2.24 22.50 10.38 24.06 8.26 1419 2.35 24.06 2.52 25.00 12.61 29.24 9.18 1577 2.85 29.24 2.80 27.50 15.05 34.88 10.09 1735 3.40 34.88 3.08 30.00 17.68 40.97 11.01 1893 4.00 40.97 3.36 32.50 20.51 47.51 11.93 2050 4.64 47.51 3.64 35.00 23.52 54.49 12.85 2208 5.32 54.49 3.92 37.50 26.73 61.91 13.76 2366 6.05 61.91 4.19 40.00 30.12 69.76 14.68 2523 6.81 69.76 4.47 42.50 33.70 78.04 15.60 2681 7.62 78.04 4.75 45.00 37.47 86.74 16.52 2839 8.47 86.74 5.03 47.50 41.41 95.87 17.43 2997 9.37 95.87 5.31 50.00 45.54 105.41 18.35 3154 10.30 105.41 5.59 52.50 49.84 115.37 19.27 3312 11.28 115.37 5.87 55.00 54.33 125.74 20.19 3470 12.29 125.74 6.15 1 1/4" TYPE “K” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D. = 1.3765 inches (34.963 mm) Nominal O.D. = 1.3750 inches (34.925 mm) Minimum O.D. = 1.3735 inches (34.887 mm) Nominal I.D. = 1.2450 inches (31.623 mm) Nominal Wall Thickness = 0.0650 inches (1.651 mm) Flow Area = 1.2174 sq. inches (785.41 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q Pressure Loss Head Loss Velocity FLOW, Q Pressure Loss Head Loss Velocity (GPM) (psi/100 ft) (ft/100 ft) (ft./sec.) (cu. cm/sec.) (kPa/100 m) (m/100 m) (m/sec.) 5.00 0.29 0.67 1.32 315 0.06 0.67 0.40 10.00 1.03 2.40 2.64 631 0.23 2.40 0.80 15.00 2.19 5.08 3.95 946 0.49 5.08 1.20 20.00 3.73 8.65 5.27 1262 0.84 8.65 1.61 25.00 5.64 13.06 6.59 1577 1.27 13.06 2.01 30.00 7.90 18.30 7.91 1893 1.79 18.30 2.41 35.00 10.51 24.34 9.22 2208 2.38 24.34 2.81 40.00 13.46 31.17 10.54 2523 3.04 31.17 3.21 45.00 16.74 38.75 11.86 2839 3.79 38.75 3.61 50.00 20.35 47.09 13.18 3154 4.60 47.09 4.02 55.00 24.27 56.18 14.49 3470 5.49 56.18 4.42 60.00 28.52 65.99 15.81 3785 6.45 65.99 4.82 65.00 33.07 76.52 17.13 4101 7.48 76.52 5.22 70.00 37.94 87.76 18.45 4416 8.58 87.76 5.62 75.00 43.11 99.71 19.77 4732 9.75 99.71 6.02 80.00 48.58 112.35 21.08 5047 10.99 112.35 6.43 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. Revision 5/12/02 A H E A D O F T H E F L O W ® www.nibco.com NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 63 1 1/4" TYPE “L” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D. = 1.3765 inches (34.963 mm) Nominal O.D. = 1.375 inches (34.925 mm) Minimum O.D. = 1.3735 inches (34.887 mm) Nominal I.D. = 1.265 inches (32.131 mm) Nominal Wall Thickness = 0.0550 inches (1.397 mm) Flow Area = 1.2568 sq. inches (810.85 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q Pressure Loss Head Loss Velocity FLOW, Q Pressure Loss Head Loss Velocity (GPM) (psi/100 ft) (ft/100 ft) (ft./sec.) (cu. cm/sec.) (kPa/100 m) (m/100 m) (m/sec.) 5.00 0.26 0.62 1.28 315 0.06 0.62 0.39 10.00 0.96 2.22 2.55 631 0.22 2.22 0.78 15.00 2.02 4.70 3.83 946 0.46 4.70 1.17 20.00 3.45 8.00 5.11 1262 0.78 8.00 1.56 25.00 5.22 12.09 6.38 1577 1.18 12.09 1.95 30.00 7.31 16.94 7.66 1893 1.65 16.94 2.33 35.00 9.73 22.53 8.93 2208 2.20 22.53 2.72 40.00 12.45 28.84 10.21 2523 2.82 28.84 3.11 45.00 15.49 35.86 11.49 2839 3.50 35.86 3.50 50.00 18.83 43.58 12.76 3154 4.26 43.58 3.89 55.00 22.46 51.98 14.04 3470 5.08 51.98 4.28 60.00 26.39 61.06 15.32 3785 5.97 61.06 4.67 65.00 30.61 70.81 16.59 4101 6.92 70.81 5.06 70.00 35.11 81.21 17.87 4416 7.94 81.21 5.45 75.00 39.89 92.27 19.15 4732 9.02 92.27 5.84 80.00 44.96 103.97 20.42 5047 10.17 103.97 6.22 1 1/4" TYPE “M” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D. = 1.3765 inches (34.963 mm) Nominal O.D. = 1.3750 inches (34.925 mm) Minimum O.D. = 1.3735 inches (34.887 mm) Nominal I.D. = 1.2910 inches (32.7914 mm) Nominal Wall Thickness = 0.0420 inches (1.067 mm) Flow Area = 1.3090 sq. inches (844.52 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q Pressure Loss Head Loss Velocity FLOW, Q Pressure Loss Head Loss Velocity (GPM) (psi/100 ft) (ft/100 ft) (ft./sec.) (cu. cm/sec.) (kPa/100 m) (m/100 m) (m/sec.) 5.00 0.24 0.56 1.23 315 0.05 0.56 0.37 10.00 0.87 2.01 2.45 631 0.20 2.01 0.75 15.00 1.83 4.26 3.68 946 0.41 4.26 1.12 20.00 3.12 7.25 4.90 1262 0.71 7.25 1.49 25.00 4.72 10.95 6.13 1577 1.07 10.95 1.87 30.00 6.62 15.34 7.35 1893 1.50 15.34 2.24 35.00 8.81 20.40 8.58 2208 1.99 20.40 2.61 40.00 11.28 26.12 9.80 2523 2.55 26.12 2.99 45.00 14.03 32.48 11.03 2839 3.17 32.48 3.36 50.00 17.05 39.47 12.25 3154 3.86 39.47 3.74 55.00 20.34 47.08 13.48 3470 4.60 47.08 4.11 60.00 23.90 55.31 14.71 3785 5.41 55.31 4.48 65.00 27.72 64.14 15.93 4101 6.27 64.14 4.86 70.00 31.80 73.56 17.16 4416 7.19 73.56 5.23 75.00 36.13 83.57 18.38 4732 8.17 83.57 5.60 80.00 40.72 94.17 19.61 5047 9.21 94.17 5.98 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. Revision 5/12/02 A H E A D O F T H E F L O W ® www.nibco.com NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 65 1 1/2" TYPE “M” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D. = 1.6270 inches (41.326 mm) Nominal O.D. = 1.6250 inches (41.275 mm) Minimum O.D. = 1.6230 inches (41.224 mm) Nominal I.D. = 1.5270 inches (38.7858 mm) Nominal Wall Thickness = 0.0490 inches (1.2446 mm) Flow Area = 1.8313 sq. inches (1181.50 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q Pressure Loss Head Loss Velocity FLOW, Q Pressure Loss Head Loss Velocity (GPM) (psi/100 ft) (ft/100 ft) (ft./sec.) (cu. cm/sec.) (kPa/100 m) (m/100 m) (m/sec.) 5.00 0.11 0.25 0.88 315 0.02 0.25 0.27 10.00 0.38 0.89 1.75 631 0.09 0.89 0.53 15.00 0.81 1.88 2.63 946 0.18 1.88 0.80 20.00 1.38 3.20 3.50 1262 0.31 3.20 1.07 25.00 2.09 4.84 4.38 1577 0.47 4.84 1.33 30.00 2.93 6.78 5.26 1893 0.66 6.78 1.60 35.00 3.89 9.02 6.13 2208 0.88 9.02 1.87 40.00 4.98 11.54 7.01 2523 1.13 11.54 2.14 45.00 6.20 14.35 7.88 2839 1.40 14.35 2.40 50.00 7.53 17.44 8.76 3154 1.70 17.44 2.67 55.00 8.99 20.80 9.64 3470 2.03 20.80 2.94 60.00 10.56 24.44 10.51 3785 2.39 24.44 3.20 65.00 12.25 28.34 11.39 4101 2.77 28.34 3.47 70.00 14.05 32.50 12.26 4416 3.18 32.50 3.74 75.00 15.96 36.92 13.14 4732 3.61 36.92 4.00 80.00 17.99 41.61 14.02 5047 4.07 41.61 4.27 85.00 20.13 46.55 14.89 5362 4.55 46.55 4.54 90.00 22.38 51.74 15.77 5678 5.06 51.74 4.81 95.00 24.73 57.18 16.64 5993 5.59 57.18 5.07 100.00 27.20 62.87 17.52 6309 6.15 62.87 5.34 105.00 29.77 68.81 18.40 6624 6.73 68.81 5.61 110.00 32.45 74.99 19.27 6940 7.34 74.99 5.87 115.00 35.23 81.42 20.15 7255 7.97 81.42 6.14 2" TYPE “K” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D. = 2.1270 inches (54.026 mm) Nominal O.D. = 2.1250 inches (53.975 mm) Minimum O.D. = 2.1230 inches (53.924 mm) Nominal I.D. = 1.9590 inches (49.7586 mm) Nominal Wall Thickness = 0.0830 inches (2.1082 mm) Flow Area = 3.0141 sq. inches (1944.58 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q Pressure Loss Head Loss Velocity FLOW, Q Pressure Loss Head Loss Velocity (GPM) (psi/100 ft) (ft/100 ft) (ft./sec.) (cu. cm/sec.) (kPa/100 m) (m/100 m) (m/sec.) 10 0.11 0.26 1.06 631 0.03 0.26 0.32 20 0.41 0.95 2.13 1262 0.09 0.95 0.65 30 0.87 2.02 3.19 1893 0.20 2.02 0.97 40 1.48 3.43 4.26 2523 0.34 3.43 1.30 50 2.24 5.19 5.32 3154 0.51 5.19 1.62 60 3.14 7.27 6.39 3785 0.71 7.27 1.95 70 4.18 9.67 7.45 4416 0.95 9.67 2.27 80 5.35 12.38 8.52 5047 1.21 12.38 2.60 90 6.66 15.39 9.58 5678 1.51 15.39 2.92 100 8.09 18.71 10.64 6309 1.83 18.71 3.24 110 9.66 22.32 11.71 6940 2.18 22.32 3.57 120 11.34 26.21 12.77 7570 2.57 26.21 3.89 130 13.16 30.40 13.84 8201 2.98 30.40 4.22 140 15.09 34.86 14.90 8832 3.41 34.86 4.54 150 17.15 39.61 15.97 9463 3.88 39.61 4.87 160 19.33 44.63 17.03 10094 4.37 44.63 5.19 170 21.62 49.93 18.10 10725 4.89 49.93 5.52 180 24.04 55.50 19.16 11356 5.44 55.50 5.84 190 26.57 61.34 20.22 11986 6.01 61.34 6.16 200 29.22 67.44 21.29 12617 6.61 67.44 6.49 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. Revision 5/12/02 A H E A D O F T H E F L O W ® www.nibco.com NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 66 2" TYPE “L” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D. = 2.1270 inches (54.026 mm) Nominal O.D. = 2.1250 inches (53.975 mm) Minimum O.D. = 2.1230 inches (53.924 mm) Nominal I.D. = 1.9850 inches (50.419 mm) Nominal Wall Thickness = 0.0700 inches (1.778 mm) Flow Area = 3.0946 sq. inches (1996.54 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q Pressure Loss Head Loss Velocity FLOW, Q Pressure Loss Head Loss Velocity (GPM) (psi/100 ft) (ft/100 ft) (ft./sec.) (cu. cm/sec.) (kPa/100 m) (m/100 m) (m/sec.) 10 0.11 0.25 1.04 631 0.02 0.25 0.32 20 0.39 0.89 2.07 1262 0.09 0.89 0.63 30 0.82 1.89 3.11 1893 0.18 1.89 0.95 40 1.39 3.22 4.15 2523 0.31 3.22 1.26 50 2.10 4.87 5.18 3154 0.48 4.87 1.58 60 2.95 6.82 6.22 3785 0.67 6.82 1.90 70 3.92 9.07 7.26 4416 0.89 9.07 2.21 80 5.02 11.61 8.29 5047 1.14 11.61 2.53 90 6.24 14.44 9.33 5678 1.41 14.44 2.84 100 7.59 17.55 10.37 6309 1.72 17.55 3.16 110 9.06 20.93 11.40 6940 2.05 20.93 3.48 120 10.64 24.58 12.44 7570 2.41 24.58 3.79 130 12.34 28.51 13.48 8201 2.79 28.51 4.11 140 14.15 32.70 14.51 8832 3.20 32.70 4.42 150 16.08 37.15 15.55 9463 3.64 37.15 4.74 160 18.13 41.86 16.59 10094 4.10 41.86 5.06 170 20.28 46.83 17.62 10725 4.59 46.83 5.37 180 22.54 52.05 18.66 11356 5.10 52.05 5.69 190 24.92 57.53 19.70 11986 5.64 57.53 6.00 200 27.40 63.25 20.73 12617 6.20 63.25 6.32 2" TYPE “M” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D. = 2.1270 inches (54.026 mm) Nominal O.D. = 2.1250 inches (53.975 mm) Minimum O.D. = 2.1230 inches (53.924 mm) Nominal I.D. = 2.0090 inches (51.0286 mm) Nominal Wall Thickness = 0.0580 inches (1.4732 mm) Flow Area = 3.1699 sq. inches (2045.11 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q Pressure Loss Head Loss Velocity FLOW, Q Pressure Loss Head Loss Velocity (GPM) (psi/100 ft) (ft/100 ft) (ft./sec.) (cu. cm/sec.) (kPa/100 m) (m/100 m) (m/sec.) 10 0.10 0.23 1.01 631 0.02 0.23 0.31 20 0.36 0.84 2.02 1262 0.08 0.84 0.62 30 0.77 1.78 3.04 1893 0.17 1.78 0.93 40 1.31 3.04 4.05 2523 0.30 3.04 1.23 50 1.98 4.59 5.06 3154 0.45 4.59 1.54 60 2.78 6.43 6.07 3785 0.63 6.43 1.85 70 3.70 8.55 7.08 4416 0.84 8.55 2.16 80 4.74 10.95 8.10 5047 1.07 10.95 2.47 90 5.89 13.62 9.11 5678 1.33 13.62 2.78 100 7.16 16.55 10.12 6309 1.62 16.55 3.08 110 8.54 19.74 11.13 6940 1.93 19.74 3.39 120 10.03 23.19 12.15 7570 2.27 23.19 3.70 130 11.64 26.89 13.16 8201 2.63 26.89 4.01 140 13.35 30.84 14.17 8832 3.02 30.84 4.32 150 15.17 35.04 15.18 9463 3.43 35.04 4.63 160 17.10 39.48 16.19 10094 3.87 39.48 4.94 170 19.13 44.17 17.21 10725 4.33 44.17 5.24 180 21.26 49.09 18.22 11356 4.81 49.09 5.55 190 23.50 54.26 19.23 11986 5.32 54.26 5.86 200 25.84 59.66 20.24 12617 5.85 59.66 6.17 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. Revision 5/12/02 A H E A D O F T H E F L O W ® www.nibco.com NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 81 Copper Water Tube continued COPPER TUBE – TYPES, STANDARDS, APPLICATIONS, TEMPERS AND LENGTHS Commercially Available Lengths Tube Type Color Code Standard Application Nominal or Standard Sizes Drawn Annealed Type K Green ASTM B 88 Domestic Water Service Distribution Straight Lengths: 1/4-inch to 8-inch 20 ft. (6.1m) 20 ft. (6.1m) Fire Protection 10-inch 18 ft. (5.5m) 18 ft. (5.5m) Solar 12-inch 12 ft. (3.7m) 12 ft. (3.7m) Fuel/Fuel Oil Coils: 1/4-inch to 1-inch – 60 ft. (18.3m) HVAC – 100 ft. (30.5m) Snow Melting 11/4-inch & 11/2-inch – 60 ft. (18.3m) 2-inch – 40 ft. (12.2m) – 45 ft. (13.7m) Type L Blue ASTM B 88 Domestic Water Service Distribution Straight Lengths: 1/4-inch to 10-inch 20 ft. (6.1m) 20 ft. (6.1m) Fire Protection 12-inch 18 ft. (5.5m) 18 ft. (5.5m) Solar Fuel/Fuel Oil Natural Gas Coils: 1/4-inch to 1-inch – 60 ft. (18.3m) Liquified Petroleum (LP) Gas – 100 ft. (30.5m) HVAC 11/4-inch & 11/2-inch – 60 ft. (18.3m) Snow Melting 2-inch – 40 ft. (12.2m) – 45 ft. (13.7m) Type M Red ASTM B 88 Domestic Water Service Distribution Straight Lengths: 1/4-inch to 12-inch 20 ft. (6.1m) N/A Fire Protection Solar Fuel/Fuel Oil HVAC Snow Melting DWV Yellow ASTM B 306 Drain Straight Lengths: 11/4-inch to 8-inch 20 ft. (6.1m) N/A Waste Vent HVAC Solar ACR Blue ASTM B 280 Air Conditioning Straight Lengths: 1/4-inch to 41/8-inch 20 ft. (6.1m) 20 ft. (6.1m)1 Refrigeration Natural Gas Coils: 1/8-inch to 15/8-inch – 50 ft. (15.3m)1 Liquified Petroleum (LP) Gas OXY Type K ASTM B 819 Medical Gas Straight Lengths: 1/4-inch to 8-inch 20 ft. (6.1m) N/A MED Green OXY/MED OXY/ACR Type L ACR/MED Blue Type G Yellow ASTM B 837 Natural Gas Straight Lengths: 3/8-inch to 11/8-inch 12 ft. (3.7m) 12 ft. (3.7m)1 Liquified Petroleum (LP) Gas 20 ft. (6.1m) 20 ft. (6.1m)1 Coils: 3/8-inch to 7/8-inch – 60 ft. (18.3m)1 – 100 ft. (30.5m)1 1 Available as special order only. U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. Revision 5/12/02 Main Office/Manufacturing Facility •1375 Sampson Ave. •Corona, CA 92879 •Ph: 909.737.5599 •Fax: 909.737.0330 Customer Service •800.786.5266 www.tolco.com 36 wwwwww..ttoollccoo..ccoomm Revision 5/24/2001 ™ ®a brand of Dimensions • Weights Data Table for Fig. 20S Pipe Hole Max. Rec. Approx. Sizes A BCDSize Load Lbs. Wt./100 1/2 4 1/8 5/16 2 7/8 3/4 7/16 410 21 3/4 4 5/16 7/16 3 15/16 7/16 410 24 149/16 9/16 3 3/8 11/8 7/16 410 26 11/4 415/16 11/16 3 3/4 11/2 7/16 410 30 11/2 53/16 13/16 4 1/4 15/8 7/16 410 33 253/4 11/16 43/4 21/4 7/16 410 38 21/2 61/4 19/16 51/4 23/4 7/16 610 102 367/8 15/8 57/8 33/8 7/16 610 118 31/2 73/8 17/8 63/8 37/8 7/16 610 130 483/8 21/8 743/8 9/16 725 159 597/16 25/8 77/8 53/8 9/16 725 191 6101/2 33/16 87/8 67/16 9/16 725 234 81441/4 111/2 83/8 11/16 900 446 Size Range — 1/2" thru 8" pipe Material — Carbon Steel Function — Recommended for supporting pipe with fittings vertically or horizontally to walls or ceiling. Fig. 20S will support pipe flush with mounting surface. Approvals — Conforms to Federal Specification WW-H-171E, Type 26 and Manufacturers Standardization Society SP-69, Type 26. Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, pipe size, material and finish Size Range — 1/2" thru 2" pipe Material — Carbon Steel Function — Light duty strap that attaches pipe or copper tubing to horizontal or vertical structure. Finish — Pre-Galvanized Note — Available with felt lining, order TOLCO™ Fig. 21F. Order By — Figure number and pipe size Fig. 20 - Standard Pipe Strap Fig. 20S - Flush Mount Pipe Strap Fig. 21 - “Tin Strap” Dimensions • Weights Data Table for Fig. 20 Pipe Hole Max. Rec. Approx. Sizes A BCDSize Load Lbs. Wt./100 1/2 3 7/8 3/4 3 1/16 15/32 7/16 410 16 3/4 4 13/16 3 1/8 15/16 7/16 410 21 149/16 7/8 3 3/8 11/2 7/16 410 26 11/4 415/16 133/4 17/8 7/16 410 30 11/2 53/16 13/16 41/4 21/8 7/16 410 33 253/4 17/16 43/4 25/8 7/16 410 38 21/2 61/4 111/16 51/4 31/8 7/16 610 102 367/8 257/8 33/4 7/16 610 118 31/2 73/8 21/4 63/8 41/4 7/16 610 130 483/8 21/2 743/4 9/16 725 159 597/16 31/16 77/8 513/16 9/16 725 191 6101/2 35/8 87/8 67/8 9/16 725 234 81445/8 111/2 9 11/16 900 446 Main Office/Manufacturing Facility • 1375 Sampson Ave. • Corona, CA 92870 • Ph: 909.737.5599 • Fax: 909.737.0330 Distribution Center • 8790 Fruitridge Road • Sacramento, CA 95826 • Ph: 916.388.7800 • Fax: 916.388.1401 Manufacturing Facility • 4851 Homestead Road, Bldg. 118 • Houston, TX 77028 • Ph: 713.672.0058 • Fax: 713.672.0074 www.tolco.com 31 Fig. 200 “Trimline” Adjustable Band Hanger Size Range – 1/2 thru 8 inch pipe. Material – Carbon Steel, Mil. Galvanized to G-90 specifications. Function – For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features · (1/2 thru 2 inch) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. · (2-1/2 thru 8 inch) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals – Underwriters' Laboratories Listed (1/2” thru 8”) in the U.S. (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4” thru 8”). Conforms to Federal Specifications WW-H-171E, Type 10, and Manufacturers Standardization Society SP-69, type 10. Maximum Temperature - 650°F. Finish – Mil. Galvanized, for Stainless Steel materials order TOLCO™ Fig. 200WON. Order By – Figure number and pipe size. Pipe Size Rod Size Inch Metric* B Max. Rec. Load bs. Approx. Wt./100 1/2 3/8 8mm or 10mm 3-1/8 2-5/8 400 11 3/4 3/8 8mm or 10mm 3-1/8 2-1/2 400 11 1 3/8 8mm or 10mm 3-3/8 2-5/8 400 12 1-1/4 3/8 8mm or 10mm 3-3/4 2-7/8 400 13 1-1/2 3/8 8mm or 10mm 3-7/8 2-7/8 400 14 2 3/8 8mm or 10mm 4-1/2 3 400 15 2-1/2 3/8 10mm 5-5/8 4-1/8 600 27 3 3/8 10mm 5-7/8 4 600 29 3-1/2 3/8 10mm 7-3/8 5-1/4 600 34 4 3/8 10mm 7-3/8 5 1000 35 5 1/2 12mm 9-1/8 6-1/4 1250 66 6 1/2 12mm 10-1/8 6-3/4 1250 73 8 1/2 12mm 13-1/8 8-3/4 1250 136 *Order Fig. 200M Revision 5/24/2001 5 To find a distributor near you, call 800-BUILDEX Not less than 2” nominal width (1-1/2”) up to 3-1/2” pipe; not less than 3” (2-1/2”) nominal width 4” & 5” pipe Minimum 2-1/2” from bottom for branch lines. Minimum 3” from bottom for main lines. Exception: This requirement shall not apply to 2” or thicker nailing strips resting on top of steel beams. Floor Joist HORIZONTAL MOUNT WOOD WOOD WOOD WOOD WOODSIDEWINDERS® for Wood Installs HORIZONTALLY into the side of wood structures easily and quickly! Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs)UL Test Load (lbs)Box Qty Case Qty 1/4"8018957 SWG 100 1/4 x 1"622 (Fir)25 125 1/4"8019957 SWG 200 1/4 x 2"1725 (Fir)25 125 3/8"8020957 SWG 10 1/4 x 1"622 (Fir)300 25 125 3/8"8021957 SWG 20 1/4 x 2"1725 (Fir)1050 25 125 3/8"8073925 SWG 20-SS 1/4 x 2"1725 (Fir)850 25 125 3/8"8022925 SWG 25-380 3/8 x 2-1/2"2249 (Fir)1500 25 125 3/8"8023925 SWG 30 1/4 x 3"1884 (Fir)25 125#14 SW Red Nut Driver Part # 8114910 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. INSTALLATION STEPS - VERTICAL INTO WOOD & STEEL: 1. Insert the appropriate nut driver into a 3/8” or 1/2” portable drill. 2. Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. 3. Push the face of the nut driver tight to the member. When the nut driver spins freely on the SAMMYS, stop drill and remove. 4. The SAMMYS is now ready to receive 1/4”, 3/8”, 1/2” or metric all thread rod, bolt stock. (The 1/2” requires the #14SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximumpullout in purlin steel. INSTALLATION STEPS - HORIZONTAL INTO WOOD & STEEL: 1. Insert the appropriate nut driver into a 3/8” or 1/2” portable drill. 2. Insert the SAMMYS into the #14SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. 3. When the nut driver spins free on the SAMMYS, stop the drill and remove. 4. The unit is now ready to receive 1/4”, 3/8” or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. Composite/TrussConsult truss manufacturer for recommended installation point. *Pre-drilling may be required for Model SWG 25-380 (tools available on pg 10 ) Product Features • No pre-drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation cost. • Made in the U.S.A. Installs VERTICALLY and swivels up to 17° in wood structure Main Office/Manufacturing Facility •1375 Sampson Ave. •Corona, CA 92879 •Ph: 909.737.5599 •Fax: 909.737.0330 Customer Service •800.786.5266 www.tolco.com 68 wwwwww..ttoollccoo..ccoomm Revision 5/24/2001 ™ ®a brand of Fig. 98 - Rod Stiffener Size Range — Secures 3/8" thru 7/8" hanger rod Material — Carbon Steel Function — Secures channel to hanger rod for vertical seismic bracing. Finish — Electro Galvanized Note — Available in HDG finish or Stainless Steel materials. Order By — Figure number Fig. 99 - All Thread Rod Cut to Length Size Range — Secures 3/8" thru 7/8" rod in 1" increments Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter, rod length and finish Fig. 100 - All Thread Rod Full Lengths Size Range — Secures 3/8" thru 7/8" rod in 10’ lengths Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter and finish Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 11/2 11630 10370 510 Series 4000B Reduced Pressure Zone Assemblies are designed to protect drinking water supplies from dangerous cross-connections in accordance with national plumbing codes and water authority requirements for health- hazard non-potable service applications such as irrigation, fire line, or indus- trial processing. This series features two in-line, independent check valves, cap tured springs and replaceable check seats with an in ter me di ate relief valve. Its compact modular de sign facilitates easy main te nance and as sem bly ac cess. Sizes 1⁄2"- 1" (15-25mm) shutoffs have tee handles. Specifications A Reduced Pressure Zone Assembly shall be in stalled at each potential health hazard location to pre vent back flow due to backsiphonage and/or back pres sure. The as sem bly shall con sist of an in ter nal pres sure differential relief valve lo cat ed in a zone be tween two pos i tive seating check mod ules with cap tured springs and silicone seat discs. Seats and seat discs shall be re place able in both check modules and the re lief valve. There shall be no threads or screws in the wa ter way ex posed to line fluids. Ser vice of all in ter nal com po nents shall be through a sin gle ac cess cover se cured with stain less steel bolts. The as sem bly shall also in clude two re sil ient seat ed iso- la tion valves, four re sil ient seat ed test cocks and an air gap drain fitting. The as sem bly shall meet the re quire ments of: USC Man u al 8th Edition†; ASSE Std. 1013; AWWA Std. C511; CSA B64.4. The assembly shall be an Ames Com pa ny Series 4000B. ES-A-4000B 2" (50mm) 4000B-HC Series 4000B Reduced Pressure Zone Assemblies Sizes: 1⁄2" – 2" (15 – 50mm) Job Name ________________________________________________Contractor ______________________________________________ Job Location ______________________________________________Approval _______________________________________________ Engineer _________________________________________________Contractor’s P.O. No. ______________________________________ Approval _________________________________________________Representative ___________________________________________ Ames product specifications in U.S. customary units and metric are ap prox i mate and are pro vid ed for ref er ence only. For precise mea sure ments, please contact Ames Technical Ser vice. Ames re serves the right to change or modify prod uct de sign, con struc tion, spec i fi ca tions, or ma te ri als with out prior notice and without in cur ring any ob li ga tion to make such chang es and mod i fi ca tions on Ames products previously or sub se quent ly sold.amesfirewater.com Features • Single access cover and modular check construction for ease of maintenance • Top entry - all internals im me di ate ly accessible • Captured springs for safe maintenance • Internal relief valve for reduced installation clearances • Replaceable seats for economical repair • Bronze body construction for durability - 1⁄2" to 2" (15-50mm) • Ball valve test cocks - screw driv er slotted -1⁄2" to 2" (15-50mm) • Large body passages provides low pressure drop • Compact, space saving design • No special tools required for servicing 1/2" (15mm) 4000B NOTICE The information contained herein is not intended to replace the full product instal- lation and safety information available or the experience of a trained product install- er. You are required to thoroughly read all installation instructions and product safety information before beginning the installa- tion of this product. 2 Pressure — Temperature Suitable for supply pressures up to 175psi (12.06 bar) and water temperature to 180°F (75°C) continuous. Available Models Suffix: B - quarter-turn ball valves LBV - less ball valves SH - stainless steel ball valve handles HC - 21⁄2" inlet/outlet fire hydrant fitting (2" valve) S - bronze strainer Prefix: U - union connections Model Size (dN) diMeNSioNS StraiNer diMeNSioNS WeigHt A B C D L M N in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kg. 4000B** 1⁄2 15 10 250 45⁄8 117 33⁄8 86 11⁄4 32 51⁄2 140 3 76 2 51 4.50 2.0 4000B M3** 3⁄4 20 103⁄4 273 5 127 31⁄2 89 11⁄2 38 63⁄4 171 35⁄16 84 25⁄16 59 5.75 2.6 4000B M2** 1 25 141⁄2 368 51⁄2 140 3 76 21⁄2 64 91⁄2 241 41⁄2 114 25⁄16 59 12.25 5.6 4000B** 11⁄4 32 173⁄8 441 6 150 31⁄2 89 21⁄2 64 113⁄8 289 51⁄8 130 31⁄8 79 14.62 6.6 4000B** 11⁄2 40 177⁄8 454 6 150 31⁄2 89 21⁄2 64 111⁄8 283 57⁄8 149 33⁄4 95 16.32 7.4 4000B** 2 50 213⁄8 543 73⁄4 197 41⁄2 114 31⁄4 83 131⁄2 343 63⁄16 157 47⁄8 124 30.00 13.6 **Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern Cal i for nia. Suffix HC - Fire Hydrant Fittings dimension "A" = 251⁄16 (637mm) M C B N l Weights — Dimensions Strainer sold separately Materials Bronze body construction, silicone rubber disc ma te ri al in the first and sec ond check plus the re lief valve. Re place able poly- mer check seats for first and sec ond checks. Re mov able stain- less steel re lief valve seat. Stain less steel cover bolts. Standardly furnished with NPT body connections. For op tion al bronze union inlet and outlet connections, spec i fy pre fix U (1⁄2" - 2")(15-50mm). Series 4000B furnished with quar ter turn, full port, re sil ient seated, bronze ball valve shutoffs. Standards AWWA C511-92, USC Manual 8th Edition, IAPMO File No. 1563 Approvals Approved by the Foundation for Cross-Connection Con trol and Hydraulic Research at the University of South ern Cal i for nia. Approval models QT, U. 1013 B64.4 3⁄4" - 2" (20-50mm) (lBV models only) d a NOTICE Inquire with governing authorities for local installation requirements It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material product, consult your local water authority, building and plumbing codes. WARNING! 3 Capacity Performance as established by an independent testing laboratory. ∆Typical maximum system flow rate (7.5 feet/sec., 2.3 meters/sec.) 1⁄4" (8mm) kPa psi 138 20 117 17 96 14 76 11 55 8 35 5 0 .25 .50 .75 1 1.17 gpm0 .95 1.9 2.9 3.8 4.5 lpm 3⁄8" (10mm) 0 .25 .50 .75 1 1.25 1.50 2.5 3.1 gpm0 .95 1.9 2.9 3.8 4.8 5.7 9.5 11.8 lpm 1⁄2" (15mm) 3⁄4" (20mm) 1" (25mm) 11⁄4" (32mm) 11⁄2" (40mm) 2" (50mm) kPa psi 138 20 117 17 96 14 76 11 55 8 35 5 kPa psi 172 25 138 20 103 15 69 10 35 5 0 1 2.5 5 7.5 10 12.5 15 gpm 0 3.8 9.5 19 28.5 38 47.5 57 lpm 5 7.5 15 fps 1.5 2.3 4.6 mps ∆P ∆P ∆P kPa psi 207 30 165 24 124 18 83 12 41 6 0 0 0 2 6 10 14 18 22 26 30 34 38 42 46 gpm 0 7.6 23 38 53 68 84 99 114 129 144 160 175 lpm 7.5 15 fps 2.3 4.6 mps ∆P kPa psi 207 30 172 25 138 20 103 15 69 10 34 5 0 0 0 5 10 20 30 40 50 60 70 80 gpm 0 19 38 76 114 152 190 228 266 304 lpm 7.5 15 fps 2.3 4.6 mps kPa psi 172 25 138 20 103 15 69 10 34 5 0 0 0 10 20 30 40 50 60 70 80 gpm 0 38 76 114 152 190 228 266 304 lpm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps ∆P ∆P kPa psi 207 30 172 25 138 20 103 15 69 10 34 5 0 0 ∆P 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 38 76 114 152 190 228 266 304 342 380 418 456 lpm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps kPa psi 207 30 172 25 138 20 103 15 69 10 34 5 0 0∆P 0 20 40 60 80 100 120 140 160 180 200 gpm 0 76 152 228 304 380 456 532 608 684 760 lpm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps ∆ ∆ ∆ ∆ ∆∆ Flow Rate Flow Rate Flow Rate Flow Rate Flow Rate Flow Rate Flow Rate Flow RatePressure LossPressure LossPressure LossPressure LossPressure LossPressure LossPressure LossPressure Loss PRINTED IN USA MKT. #8800003 - REV X MFG. #5400802 - 12/01 VSR-SF VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD FOR SMALL PIPE PAGE 1 OF 2 UL, ULC, CSFM Listed and NYMEA Accepted, CE Marked Service Pressure: Up to 250 PSI (17,2 BAR) Minimum Flow Rate for Alarm: 8-10 GPM (30-38 Lpm) Maximum Surge: 18 FPS (10 m/s) Enclosure:Die-cast, red enamel finish Cover held in place with tamper resistant screws Contact Ratings:Two sets of SPDT (Form C) 15.0 Amps at 125/250 VAC 2.0 Amps at 30 VDC Conduit Entrances: Two knockouts provided for 1/2" conduit. Usage:Listed plastic, copper and schedule 40 iron pipe. Fits pipe sizes - 1" (25mm), 1 1/4" (32mm), 1 1/2" (38mm) and 2" (50mm) Note: 12 paddles are furnished with each unit, one for each pipe size of threaded and sweat TEE, one for 1" (25mm) CPVC, one for 1" (25mm) CPVC (Central), one for 1 1/2" (38mm) polybutylene and one for 1 1/2" (38mm) threaded (Japan). (CTS-Copper tubing size) Environmental Specifications: • Suitable for indoor or outdoor use with factory installed gasket and die-cast housing. • NEMA 4/IP55 rated enclosure - use with appropriate conduit fitting. • Temperature range: 40° F to 120° F, 4,5° C to 49° C) Caution:This device is not intended for applications in explosive environments. Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 Optional: Cover Tamper Switch Kit, Stock No. 0090018 Stock No. 1113000 U.S. Pat. No. 3921989, Canadian Pat. No. 1009680 Other Patents Pending The Model VSR-SF is a vane type waterflow switch for use on wet sprinkler systems that use 1" (25mm), 1 1/4" (32mm), 1 1/2" (38mm) or 2" (50mm) pipe size. The unit may also be used as a sectional waterflow detector on large systems. The unit contains two single pole double throw snap action switches and an adjustable, instantly recycling pneumatic re- tard. The switches are actuated when a flow of 8-10 gallons per minute (30-38 Lpm) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. INSTALLATION: These devices may be mounted in horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will be accessible. The units should not be installed within 6" (15cm) of a valve, drain or fitting which changes the direction of the waterflow. The unit has a 1" NPT bushing for threading into a non-corrosive TEE. See Fig. 2 for proper TEE size, type and installation. Screw the device into the TEE fitting as shown in Fig. 2. Care must be taken to properly orient the device for the direction of waterflow. The vane must not rub the inside of the TEE or bind in any way. The stem should move freely when operated by hand. The device can also be used in copper or plastic pipe installa- tions with the proper adapters so that the specified TEE fitting may be installed on the pipe run. INSPECTION AND TESTING: Check the operation of the unit by opening the inspector’s test valve at the end of the sprinkler line or the drain and test connection, if an inspector’s test valve is not provided. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR-SF is not recommended or advisable The frequency of the inspection and testing and its associated protective monitoring system should be in accordance with the applicable NFPA Codes and Standards and/or authority having jurisdiction (manufacturer recommends quarterly or more fre- quently). Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MKT. #8800003 - REV X MFG. #5400802 - 12/01 VSR-SF VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD FOR SMALL PIPE PAGE 2 OF 2 CAUTION: An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. FIG. 1 Important: There are 12 paddles fur- nished with each unit. One for each size of threaded, sweat or plastic TEE as described in Fig. 2. These paddles have raised lettering that shows the pipe size and type of TEE that they are to be used with. The proper paddle must be used. The paddle must be properly attached (see drawing) and the screw that holds the pad- dle must be securely tight- ened. FIG. 2 NOTES: 1. The model VSR-SF has two switches, one can be used to operate a central station, proprietary or remote signal- ing unit, while the other is used to operate a local au- dible or visual annunciator. 2. For supervised circuits see “Switch Terminal Connec- tions” drawing and caution note (Fig. 3). FIG. 4 TYPICAL ELECTRICAL CONNECTIONS Retard Adjustment: To change time, turn knob (either direction) for desired time delay. Use the minimum amount of retard necessary to prevent false alarms. A “B” setting is usually adequate for this. Factory set at “B”. FIG. 3 SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL FIG. 5 To remove knockouts: Place screwdriver at edge of knock- outs, not in the center. APPLICATION WARNING! Due to the possibility of unintended discharges caused by pressure surges, trapped air, or short retard times, waterflow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Screw the device into the tee fitting as shown. Care must be taken to properly orient the device for the direction of waterflow. On sweat tees, no threaded bushings, inserts, or adapters are permitted, unless they comply with the dimensions listed in the chart below. Important - The depth to the inside bottom of the tee should have the following dimensions: PRINTED IN USA RBVS UNIVERSAL BALL VALVE SWITCH PAGE 1 OF 2MFG.# 5401086 - REV U 5/08 US Patent No. 6,945,509 General The Model RBVS is designed to monitor the fully open position of a ball valve installed in a sprinkler system. The unit will fi t on most ball valves installed on back-fl ow-preventers and alarm trim lines of dry, alarm, and deluge sprinkler valves. The switch operates if the ball valve handle is moved from the open position. However, the switch does not track the position of the handle or ball. When the ball valve handle is in the open position, a spring-loaded switch button will contact the valve handle. When the handle is moved from the open position, this switch button extends to the tripped position, and the RBVS contacts change state, thereby opening or closing a circuit. A cover tamper switch is available and is activated by the removal of the RBVS housing cover. If an attempt is made to remove the RBVS by the removal of the mounting brackets, the unit will be set into the tripped mode by this action. The RBVS can be mounted to the hex portion of the ball valve or back-fl ow- preventer or to the adjoining pipe via two clamps. The RBVS is shipped with two sets of mounting clamps to accommodate various pipe and valve sizes, refer to Table 1. An "L" shaped and offset bracket for mounting the switch enclosure and an extension bracket add to the mounting fl exibility of the RBVS. See "Typical Mounting Diagram" and "Installation and Operation" on following page. Testing The RBVS and its associated protective monitoring system should be tested in accordance with applicable NFPA codes and standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). UL and cUL Listed, FM, CSFM Approved Dimensions: (including mounting clamps) Large Clamps: 6" L x 5" W x 5.2" H 15,2 cm L x 12,7 cm W x 13,2 cm H Small Clamps: 6" L x 4" W x 5.2" H 15,2 cm L x 10,2 cm W x 13,2 cm H Weight: With Large Clamps: 13.6 oz. (386,9 g.) With Small Clamps: 11.0 oz. (311,2 g.) Enclosure: Non-Corrosive Composite Material Environmental Limitations: • NEMA 4 rated enclosure when proper electrical fi ttings are used. (IP67) • Temperature range: -40°F to 150°F (-40°C to 65°C) • Not for use in hazardous locations Housing Cover Tamper: Activated by housing cover removal (Stock No. 1000035 only) Contact Ratings: SPDT Contacts: 10A at 125/250 VAC 2A at 30 VDC SPDT Cover Tamper: 3A at 250 VAC Fig.1 Internal Components Potter Electric Signal Company, LLC • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com RBVS Stock No. 1000040 (w/o Cover Tamper) RBVS-T Stock No. 1000035 (w/Cover Tamper) Installation On Lever Handle (See Fig. 2) 1. Select clamps and clamping bolts based upon pipe/valve size, see Table 1. 2. Insert rubber clamp grippers into clamps, see Fig. 2. 3. Place one clamp on top of pipe/ball valve near the valve handle and insert clamping bolts through it. 4. Place other clamp over clamping bolts from beneath the installation and thread hex nuts onto the clamping bolts, but do not fully tighten, (be sure hex nuts seat properly in clamp hex recesses). (NOTE: Some installations may require one of the mounting bolts to be inserted from the bottom of the brackets and then trimmed to allow the extension bracket to clear. See Fig. 4) 5. Attach extension bracket (if necessary to use for positioning) to top clamp using ¼-20 X ¾" Hex bolt and washer, but do not fully tighten. 6. Attach "L" bracket (RBVS switch enclosure is loosely attached to "L" bracket) to extension bracket using ¼-20 X ¾" Hex bolt and washer, but do not fully tighten. 7. Be sure ball valve is in the fully open position. 8. Slide loosely assembled RBVS switch enclosure to a position that permits the switch button to contact the valve handle approximately 1" from its inside end. See Fig. 1 for approximate location. Cut and remove the plastic coating from the ball valve handle to allow the RBVS switch button to contact (and be activated by) the metal of the handle. 9. Tighten clamping screws alternately to an eventual 30 in-lbs. (minimum) of torque. 10. Maintain position of switch enclosure over valve handle and secure bolt that holds the extension bracket to the clamping assembly. It may be necessary to close valve to access this bolt. 11. Position "L" bracket so that it contacts the back edge of the valve handle, and secure its bolt. It may be necessary to close valve to access this bolt. 12. With the actuator fully retracted, position RBVS switch enclosure to contact the valve handle squarely, see Fig. 1. 13. With RBVS switch enclosure held squarely in contact with valve handle, securely tighten the two tamper resistant screws on the backside of the enclosure. 14. Close and open the valve to verify operation. The actuator should easily retract when the valve handle is in the open position. 15. Fully open the valve. 16. Remove the cover and wire main switch and tamper switch if applicable. Carefully route tamper switch wires through strain relief channel in switch enclosure. Fully seat the wires into the bottom of the channel. See Fig. 1.17. Replace RBVS switch enclosure cover and securely tighten cover screw. PRINTED IN USA RBVS UNIVERSAL BALL VALVE SWITCH MFG.# 5401086 - REV U 5/08 PAGE 2 OF 2 OUTG O I N G INCO M I N G DWG# 923-3 Installation on Tee Handle (See Fig. 3)1. Select clamps and clamping bolts based upon pipe/valve size, see Table 1. 2. Insert rubber clamp grippers into clamps, See Fig. 3.3. Place one clamp on top of pipe/ball valve near the valve handle and insert clamping bolts through it.4. Place other clamp over clamping bolts from beneath the installation and thread hex nuts onto the clamping bolts, but do not fully tighten, (be sure hex nuts seat properly in clamp hex recesses). 5. Loosely attach "L" bracket to the "offset" bracket and "offset" bracket to the RBVS housing. 6. Be sure ball valve is in the fully open position.7. Slide loosely assembled RBVS switch enclosure to a position that permits the switch button to contact the valve handle approximately 1/2" from the end of the handle. Cut and remove the plastic coating from the ball valve handle to allow the RBVS switch button to contact (and be activated by) the metal of the handle. 8. Tighten clamping screws alternately and ¼-20 X ¾" bolt to 30 in-lbs. (minimum) of torque. 9. With the valve handle fully open, slide the RBVS housing down until the switch operates plus 1/8 inch. Tighten the screws holding the RBVS to the "offset" bracket.10. Remove the RBVS switch enclosure cover. 11. Close and open the valve to verify operation. The actuator should easily retract up when the valve handle is in the open position. 12. Fully open the valve.13. Wire main switch and tamper switch (if applicable). Carefully route tamper switch wires through strain relief channel in switch enclosure. Fully seat the wires into the bottom of the channel. See Fig. 1. 14. Replace RBVS switch enclosure cover and securely tighten cover screw. Fig. 3 Typical Electrical Connections Fig. 2 Typical Mounting Diagram Tamper Switch Connections Switch Terminal Connections, Clamping Plate Terminal Table 1 Clamp Sizing Fig. 4 SOME INSTALLATIONS MAY CAUSE INTERFERENCE BETWEEN MOUNTING BOLT AND OFFSET BRACKET. INSTALL BOLT FROM BOTTOM AND TRIM AS NEEDED TO CORRECT. RBVS PIPE DWG# 1086-6 Pipe Valve/Size Clamp Clamping Bolts 1/2" to 3/4" (12,5 to 19mm) Small 10-32 x 2 1/2 1" to 2" (25 to 50mm) Large 1/4-20 x 4" An uninsulated section of single conductor should not be looped around the terminal and serve as two seperate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. MFG. #5400930 - REV D 1/08 PRINTED IN USA PAGE 1 OF 3 PS40 SERIES PRESSURE SWITCH Installation The Potter PS40 Series Pressure Actuated Switches are designed primarily to detect an increase and/or decrease from normal system pressure in automatic fi re sprinkler systems. Typical applications are: Dry pipe system, pre-action air/nitrogen supervision, pressure tanks, air supplies, and water supplies. The PS40 switch is factory set for 40 PSI (2,8 BAR) normal system pressure. The switch marked with the word LOW is set to operate at a pressure decrease of 10 PSI (,7 BAR) at 30 PSI (2,1 BAR). The switch marked with the word HIGH is set to operate at a pressure increase of 10 PSI (,7 BAR) at 50 PSI (3,5 BAR). See section heading Adjustments and Testing if other than factory set point is required. 1. Connect the PS40 to the system side of any shutoff or check valve. 2. Apply Tefl on tape to the threaded male connection on the device. (Do not use pipe dope) 3. Device should be mounted in the upright position. (Threaded connection down) 4. Tighten the device using a wrench on the fl ats on the device. Wiring Instructions 1. Remove the tamper resistant screw with the special key provided. 2. Carefully place a screwdriver on the edge of the knockout and sharply apply a force suffi cient to dislodge the knockout plug. See Fig. 9 3. Run wires through an approved conduit connector and affi x the connector to the device. A NEMA-4 rated conduit fi tting is required for outdoor use. (UL, cUL, and CSFM Listed, FM and LPC Approved, NYMEA Accepted, CE Marked Pending) Dimensions: 3.78" (9,6cm)W x 3.20" (8,1cm)D x 4.22" (10,7cm)H Conduit Entrance: Two knockouts provided for 1/2" conduit. Individual switch compartments and ground screw suitable for dissimilar voltages Enclosure: Cover- Die-cast with textured red powdercoat fi nish, single cover screw and rain lip. Base- Die-cast Pressure Connection: Nylon 1/2" NPT male Factory Adjustment: PS40-1 operates on decrease at 30 PSI (2,1 BAR) PS40-2 operates in increase at 50 PSI (3,5 BAR) and on decrease at 30 PSI (2,1 BAR) Pressure Range: 10-60 PSI (,7 - 4,1 BAR) Differential: Typical 1 lb. at 10 PSI (,07 at ,7 BAR) 4 lbs at 60 PSI (,28 at 4,1 BAR) Maximum System Pressure: 300 PSI (20,68 BAR) Switch Contacts: SPDT (Form C) 10.1 Amps at 125/250VAC, 2.0 Amps at 30VDC One SPDT in PS40-1, Two SPDT in PS40-2 Environmental Specifi cations: NEMA 4/IP55 Rated Enclosure - indoor or outdoor when used with NEMA 4 conduit fi ttings. Temperature range: -40°F to 140°F (-40°C to 60°C) Tamper: Cover incorporates tamper resistant fastener that requires a special key for removal. One key is supplied with each device. For optional cover tamper switch kit, order Stock No. 0090200. See bulletin #5401200 PSCTSK. Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential Occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-0988/Canada 888-882-1833 • www.pottersignal.com Ordering Information Model Description Stock No. PS40-1 Pressure switch with one set SPDT contacts 1340403 PS40-2 Pressure switch with two sets SPDT contacts 1340404 Hex Key 5250062 Cover Tamper Switch Kit 0090200 BVL Bleeder valve 1000018 4. Connect the wires to the appropriate terminal connections for the service intended. See Figures 2,4,5,6, and 8 Adjustment And Testing The operation of the pressure supervisory switch should be tested upon completion of installation and periodically thereafter in accordance with the applicable NFPA codes and standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). Note: Testing the PS40 may activate other system connected devices. The use of a Potter BVL (see product bulletin 8900067 for details) is recommended to facilitate setting and testing of the PS40 pressure switch. When a BVL (bleeder valve) is used, the pressure to the switch can be isolated and bled from the exhaust port on the BVL without effecting the supervisory pressure of the entire system. See Fig. 3 The operation point of the PS40 Pressure Switch can be adjusted to any point between 10 and 60 PSI (0,7 - 4,11 BAR) by turning the adjustment knob(s) clockwise to raise the actuation point and counter clockwise to lower the actuation point. In the case of the PS40-2, both switches operate independent of each other. Each switch may be independently adjusted to actuate at any point acrosss the switch adjustment range. Initial adjustment can be made with a visual reference from the top of the adjustment knob across to the printed scale on the switch bracket. Final adjustments should be verifi ed with a pressure gauge. MFG. #5400930 - REV D 1/08 PRINTED IN USA PAGE 2 OF 3 PS40 SERIES PRESSURE SWITCH Typical Sprinkler Applications Switch Clamping Plate TerminalDimensions OUTG OI N G INCOM I N G DWG# 923-3 Fig. 1 Fig. 2 Fig. 3 GONG MOTOR WATER TEST BY-PASS WATER VALVE OS & Y VALVE ALARM PRESSURE SWITCH PS10 CHECK VALVE VALVE CHECK BVL VALVE TEST BLEEDER AIR LINE SHUT-OFF VALVE PS40 DWG. #924-1A RBVS DRY PIPE VALVE Typical Connections Fig. 4 An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. Closing of any shutoff valves between the alarm check valve and the PS10 will render the PS10 inoperative. To comply with NFPA- 72 any such valve shall be electrically supervised with a supervisory switch such as Potter Model RBVS. NOTE: To prevent leakage, apply Teflon tape sealant to male threads only. 2.87 [72.97] 4.22 [107.19] 2.48 [62.87] 3.78 [95.89] 3.20 [81.28] 1.60 [40.64] GROUND SCREWS DWG# 930-1 1/2" NPT ADJUSTMENT KNOB COM 1 2 EOLRTO FIRE ALARM PANEL TO FIRE ALARM PANEL COM12 21COM HIGH AIR LOW AIR PS40-1 PS40-2WITH NORMAL SYSTEM PRES- SURE APPLIED LOW -TERMINAL 2 CLOSES ON PRESSURE DROP. WITH NORMAL SYSTEM PRESSURE APPLIED HIGH - TERMINAL 1 WILL CLOSE ON PRESSURE INCREASE. EOLR DWG# 930-2 MFG. #5400930 - REV D 1/08 PRINTED IN USA PAGE 3 OF 3 PS40 SERIES PRESSURE SWITCH DWG# 928-4 Break out thin section of divider to provide path for wires when wiring both switches from one conduit entrance. One Conduit Wiring Fig. 6 Fig. 8 DWG#928-5 Fig. 9 Removing Knockouts NC NC NO NO C C C 12 C 12 LOW PRESSURE SWITCH HIGH PRESSURE SWITCH DWG# 930-3 Changing Pressure Low Pressure Signal Connection EOLR TO FIRE ALARM PANEL DWG# 928-1 EOLR TO FIRE ALARM PANEL DWG# 928-2 High Pressure Signal Connection Fig. 5 Fig. 7 (With normal system pressure) Engineer/Architect Specifi cations Pressure Type Waterfl ow Switch Pressure type supervisory switches; shall be a Model PS40 as manufactured by Potter Electric Signal Company, St. Louis, MO., and shall be installed on the fi re sprinkler system as shown and or specifi ed herein. Switches shall be provided with a 1/2" NPT male pressure connection to be connected into the air supply line on the system side of any shut-off valve. A Model BVL bleeder valve as supplied by Potter Electric Signal Company of St. Louis, MO., or equivalent shall be connected in line with the PS40 to provide a means of testing the operation of the supervisory switch. (See Fig. 3) The switch unit shall contain SPDT (Form C) switch(es). One switch shall be set to operate at a pressure decrease of 10 PSI (0,7 BAR) from normal. If two switches are provided, the second switch shall be set to operate at a pressure increase of 10 PSI (0,7 BAR) from normal. Switch contacts shall be rated at 10.1 Amps at 125/250VAC and 2.0 Amps at 30VDC. The units shall have a maximum pressure rating of 300 PSI (20,68 BAR) and shall be adjustable from 10 to 60 PSI (0,7 to 4,1 BAR). Pressure switches shall have two conduit entrances, one for each individual switch compartment to facilitate the use of dissimilar voltages for each individual switch. The cover of the pressure switch shall be zinc die-cast with rain lip and shall attach with one tamper resistant screw. The pressure switch shall be suitable for indoor or outdoor service with a NEMA-4/IP55 rating. The pressure switch shall be UL, ULC, and CSFM listed, FM and LPC approved and NYMEA accepted. •Installation must be performed by qualifi ed personnel and in accordance with all national and local codes and ordinances. •Shock hazard. Disconnect power source before servicing. Serious injury or death could result. •Read all instructions carefully and understand them before starting installation. Save instructions for future use. Failure to read and understand instructions could result in improper operation of device resulting in serious injury or death. •Risk of explosion. Not for use is hazardous locations. Serious injury or death could result. •Do not tighten by grasping the switch enclosure. Use wrenching fl ats on the bushing only. Failure to install properly could damage the switch and cause improper operation resulting in damage to equipment and property. •To seal threads, apply Tefl on tape to male threads only. Using joint compounds or cement can obstruct the pressure port inlet and result in improper device operation and damage to equipment. •Do not over tighten the device, standard piping practices apply. Terminal C: Common1: Closed when installed under normal system pressure. 2: Open when installed under normal system pressure. Closes on pressure drop. Use for low air signal. Terminal 1: Open when installed under normal system pressure. Closes on increase in pressure. Use for high air signal. 2: Closed under normal system pressure. Model 1011A TESTa n DRaIn® Di m e n s i o n s Orifice Size Available: 3⁄8", 7⁄16", 1⁄2", 17⁄32", ELO (5⁄8")*, ESFR (3⁄4")*, & K25** SIZE A B C D E F G H ¾"79⁄16"(191 mm)11⁄2"(37.5 mm)23⁄16"(57 mm)35⁄8"(93 mm)33⁄8"(86 mm)113⁄16"(46 mm)49⁄16"(117 mm)63⁄8"(162.5 mm) 1"79⁄16" (191 mm) 11⁄2" (37.5 mm) 23⁄16" (57 mm) 35⁄8" (93 mm) 33⁄8" (86 mm) 113⁄16" (46 mm) 49⁄16" (117 mm) 63⁄8" (162.5 mm) 11⁄4"715⁄16" (201 mm) 111⁄16" (43 mm) 29⁄16" (65 mm) 41⁄4" (108 mm) 35⁄8" (91 mm) 115⁄16" (51 mm) 59⁄16" (141 mm) 51⁄2" (192 mm) 1½"815⁄16" (227 mm) 113⁄16" (45 mm) 31⁄4" (81.5 mm) 51⁄16" (127 mm) 37⁄8" (99 mm) 25⁄8" (67 mm) 81⁄4" (207 mm) 107⁄8" (274 mm) 2"815⁄16" (227 mm) 113⁄16" (45 mm) 31⁄4" (81.5 mm) 51⁄16" (127 mm) 37⁄8" (99 mm) 25⁄8" (67 mm) 81⁄4" (207 mm) 107⁄8" (274 mm) * Available on 11⁄4" to 2" size units only ** Available on 11⁄2" and 2" size units only TO DRAIN TO DRAIN H F G E A A INLET D B C Ap p r o v A l s UL and ULC Listed: (EX4019 & EX4533) FM Approved NYC-BSA No. 720-87-SM Job Name:__________________________________ Architect: ___________________________________ Engineer: ___________________________________ Contractor: _________________________________ USA Patent # 4741361 and Other Patents Pending mA t e r i A l s Handle: Steel Stem: Rod Brass Ball: C.P. Brass Body: Bronze Valve Seat: Impregnated Teflon® Indicator Plate: Steel Relief Valve: Bronze Bypass Fittings: Brass Bypass Tubing: Nylobraid mo D e l 1011A - Fr o n t vi e w mo D e l 1011A - pl A n vi e w AGF Manufacturing Inc. 100 Quaker Lane, Malvern, PA 19355 Phone: 610-240-4900 Fax: 610-240-4906 www.testandrain.com Model 1011A 300 PSI Bronze Ball Valve, Model 7000 Pressure Relief Valve Factory Rated at 175 PSI with other settings available th e mo D e l 1011A p r o v i D e s A l l o F t h e F o l l o w i n g … From the 2007 Edition of NFPA 13 Chapter 8.16.2.4.1* Provisions shall be made to properly drain all parts of the system. Chapter 8.16.2.4.2 Drain connections, interior sectional or floor control valve(s) – shall be provided with a drain connection having a minimum size as shown in Table 8.16.2.4.2. Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drain. Chapter A.8.17.4.2 (Wet Pipe System) test connection is permitted to terminate into a drain capable of accepting full flow… using an approved sight test connection containing a smooth bore corrosion-resistant orifice giving a flow equivalent to one sprinkler… Chapter 8.17.4.2.2 The test connection valve shall be readily accessible. Chapter 8.17.4.2.4 shall be permitted to be installed in any location… downstream of the waterflow alarm. Chapter 8.17.4.3.1 (Dry Pipe System) a trip test connection not less than 1" in diameter, terminating in a smooth bore corrosion-resistant orifice, to provide a flow equivalent to one sprinkler… Chapter 8.17.4.3.2 The trip test connection… with a shutoff valve and plug not less than 1", at least one of which shall be brass. Chapter 7.1.2 - a gridded wet pipe system shall be provided with a relief valve set to operate at 175 PSI or 10 PSI in excess of the maximum system pressure, whichever is greater. Chapter 8.16.1.2.3* A relief valve of not less than ½" in size shall be provided on the discharge side of the pressure-reducing valve set to operate at a pressure not exceeding 175 PSI. Chapter A.8.16.1.2.3 - consideration should be given to piping the discharge from the (pressure relief) valve & 8.16.2.4.3 Specifications · Material List Size 1 in C - Height Closed 4.38 in B - Diameter 2.75 in A - Length 1.47 in Ship Weight 1.76 lb Quantity Unit Pack 6 Quantity per Case 36 Valve Type Angle Valve Pressure Class 125 psi 200 WOG 125 WSP Specifications Item # Model 126SUL - 1", Model 126SUL Angle Valve Soft Disc UL Listed for Fire Sprinkler Service at 250 WOG 200 WOG at 180 ° Max 100% Pressure Tested Threaded Ends Rising Stem Integral Seat *Contains lead. Not for use in water systems intended for human consumption* larger image larger image United Brass Works, Inc. 714 South Main Street Randleman, NC 27317 USA Phone: 336-498-2661 Fax: 336-498-4267 Toll-free: 800-334-3035 Email: sales@ubw.com Website: http://www.ubw.com All Categories > Fire Protection Valves & Products > Fire Protection Products - Angle Valves > Model 126SUL Angle Valve > Item # Model 126SUL - 1" United Brass Works, Inc. - Item # Model 126SUL - 1", Model 126SUL ... http://ubw.thomasnet.com/printitem/fire-protection-products-angle-valve... 1 of 2 10/29/2011 2:59 PM End Connection Threaded Application Gas Oil Water Stem Type Rising Bonnet Type Screwed UL Listed Yes FM Approved No MEA Approved No MSS Compliant No Canadian Registration No Pressing Machine Part No Material List United Brass Works, Inc. - Item # Model 126SUL - 1", Model 126SUL ... http://ubw.thomasnet.com/printitem/fire-protection-products-angle-valve... 2 of 2 10/29/2011 2:59 PM Specifications · Material List Size 1 in A - Total Length 2.97 in C - Height Closed 4.25 in B - Diameter 2.75 in Ship Weight 1.76 lb Quantity Unit Pack 6 Quantity per Case 36 Valve Type Globe Valve Pressure Class 125 psi 200 WOG 125 WSP Specifications Item # Model 125SUL - 1", Model 125SUL Globe Valve Soft Disc UL Listed for Fire Sprinkler Service at 250 WOG 200 WOG at 180 ° Max 100% Pressure Tested Threaded Ends Integral Seat Rising Stem Swivel Disc Holder *Contains lead. Not for use in water systems intended for human consumption* larger image larger image United Brass Works, Inc. 714 South Main Street Randleman, NC 27317 USA Phone: 336-498-2661 Fax: 336-498-4267 Toll-free: 800-334-3035 Email: sales@ubw.com Website: http://www.ubw.com All Categories > Fire Protection Valves & Products > Fire Protection Products - Globe Valves > Model 125SUL Globe Valve > Item # Model 125SUL - 1" United Brass Works, Inc. - Item # Model 125SUL - 1", Model 125SUL ... http://ubw.thomasnet.com/printitem/fire-protection-products-globe-valv... 1 of 2 10/29/2011 3:01 PM End Connection Threaded Application Gas Oil Water Stem Type Rising Bonnet Type Screwed UL Listed Yes FM Approved No MEA Approved No MSS Compliant No Canadian Registration No Pressing Machine Part No Material List United Brass Works, Inc. - Item # Model 125SUL - 1", Model 125SUL ... http://ubw.thomasnet.com/printitem/fire-protection-products-globe-valv... 2 of 2 10/29/2011 3:01 PM Specifications · Material List Size 1-1/4 in A 3.45 in B 2.20 in Ship Weight 1.81 lb Quantity per Carton 6 Quantity per Case 18 Valve Type Check Valve Pressure Class 200 WOG End Connection Threaded Application Gas Oil Water UL Listed No FM Approved No MEA Approved No MSS Compliant No Specifications Item # Model 99S 11/4", Model 99S Swing Check Valve larger image larger image United Brass Works, Inc. 714 South Main Street Randleman, NC 27317 USA Phone: 336-498-2661 Fax: 336-498-4267 Toll-free: 800-334-3035 Email: sales@ubw.com Website: http://www.ubw.com All Categories > Fire Protection Valves & Products > Fire Protection Products - Swing Check Valves > Model 99S Swing Check Valve > Item # Model 99S 11/4" United Brass Works, Inc. - Item # Model 99S 11/4", Model 99S Swing C... http://ubw.thomasnet.com/printitem/fire-protection-products-swing-chec... 1 of 2 10/29/2011 3:02 PM Canadian Registration No Material List United Brass Works, Inc. - Item # Model 99S 11/4", Model 99S Swing C... http://ubw.thomasnet.com/printitem/fire-protection-products-swing-chec... 2 of 2 10/29/2011 3:02 PM FIRE DEPT. INLET CONN. FLUSH TYPE 6341-6345 SERIES SINGLE INLET An inlet connection with 250 G.P.M. minimum inlet capacity to supplement the fire protection water supply. Provides unobstructed water supply. Flush round design enhances appearance and provides unobstructed passage. STANDARD EQUIPMENT:Cast Brass round plate with double female adapter; plug and chain; branding as selected. SPECIFY THREAD AND BRANDING. BRANDING:"Standpipe", "Auto Spkr." FINISH:Cast Brass OPTIONAL FINISH:PB-Polished Brass PC-Polished Chrome RESIDENTIAL FIRE DEPT. CONNECTION An inlet connection to supplement the water supply to a residential sprinkler system. STANDARD EQUIPMENT:1 1/2" cast brass round plate assembly with integral pin lug swivel inlet. Hose thread inlet swivel, 1 1/2" NPT female outlet on back of plate. Cast brass plug and brass chain. Overall outside Diameter 4 3/8". SPECIFY THREAD AND BRANDING. U/L LISTED. BRANDING:"Auto Spkr." FINISH:Cast Brass OPTIONAL FINISH:PB-Polished Brass PC-Polished Chrome Figure No. 6341 Figure No. 6342 Figure No. 6345 Page 6-12 Round Plate Figure No. Size 6341 21/2X21/2 6342 3X21/2 6343 3X3 ___________________________________________________ Submittal data sheets can ONLY be ordered as a "Submittal Data Sheet Pack", using MC# 4400. They are not available to order on an indi- vidual basis, however each data sheet is available on the Amtrol Web Site and can be downloaded and printed for use as needed. Rev. 03/06 18 FIRE-X-TROL® FPT Series, Fire Protection Expansion Tanks (ASME) B A FPT-5-C FPT-12-C CHARGING VALVE SYSTEM CONNECTION MODELS: B A FPT-20V-C -30V-C -42V-C -60V-C CHARGING VALVE c -70V-C FPT FPT FPT FPT SYSTEM CONNECTION MODELS: In-Line Models Model Tank A B Sys. Ship No. Vol. Height Diameter Conn. Wt. Lit. Gal. mm ins. mm ins. ins. kg lbs. FPT-5-C 15 2.1 264 10 3⁄8 254 10 3⁄4 NPTF 9.5 21 FPT-12-C 24 6.4 397 15 5⁄8 305 12 3⁄4 NPTF 15.4 36 Maximum Operating Conditions Operating Temperature -20°F (-29°C) to 200°F (93°C) Working Pressure 175 PSIG (12 bar) Specifications Description Standard Construction Standard Factory Pre-charge 25 PSIG (1.7 bar) System Connection Stainless Steel Diaphragm Material High-Performance Rubber Compound Liner Material Polypropylene Shell Steel Coating FPT Red Fluid Compatibility With or Without Antifreeze Per NFPA 13 Stand Models Model Tank A B C Sys. Ship No. Vol. Height Diameter Dim. Conn. Wt. Lit. Gal. mm ins. mm ins. mm ins. ins. kg lbs. FPT-20V-C 30 8.0 495 19 1⁄2 305 12 273 10 3⁄4 3⁄4 NPTF 23.6 52 FPT-30V-C 53 14.0 486 19 1⁄8 419 16 1⁄4 324 12 3⁄4 3⁄4 NPTF 44 97 FPT-42V-C 66 17.5 616 24 1⁄4 419 16 1⁄4 324 12 3⁄4 3⁄4 NPTF 52.7 116 FPT-60V-C 95 25.0 838 33 419 16 1⁄4 324 12 3⁄4 3⁄4 NPTF 70 154 FPT-70V-C 129 34.0 1054 41 1⁄2 419 16 1⁄4 324 12 3⁄4 3⁄4 NPTF 90 197 FPT-80V-C 200 53.0 908 35 3⁄4 610 24 406 16 1 1⁄4 NPTF 114 251 FPT-120V-C 250 66.0 1111 43 3⁄4 610 24 406 16 1 1⁄4 NPTF 127.6 281 FPT-180V-C 292 77.0 1235 48 5⁄8 610 24 406 16 1 1⁄4 NPTF 160.3 353 FPT-210V-C 341 90.0 1410 55 1⁄2 610 24 406 16 1 1⁄4 NPTF 173.4 382 Job Name___________________________________________ Location ____________________________________________ ____________________________________________ ____________________________________________ Engineer ____________________________________________ Contractor __________________________________________ Contractor P.O. No.___________________________________ Sales Representative _________________________________ Model No. Ordered ___________________________________ Constructed per ASME Code Section VIII, Division 1. All dimensions and weights are approximate. 175 PSIG Working Pressure 2 GOULDS PUMPSCommercial Water A Full Range of Product Features Una Gama Total de Características del Producto Superior Materials of Construction: Complete AISI 316L stainless steel liquid handling components and mounting bracket for corrosion resistance, quality appearance, and improved strength and ductility. High Efficiency Impeller: Enclosed impeller with unique floating seal ring design maintains maximum efficiencies over the life of the pump without adjustment. Casing and Adapter Features: Stainless steel construction with NPT threaded, centerline connec- tions, easily accessible vent, prime and drain connections with stain- less steel plugs. Optional seal face vent/flush available. Mechanical Seal: Standard John Crane Type 21 with carbon versus silicon-carbide faces, Viton elastomers, and 316 stainless metal parts. Optional high temperature and chemical duty seals available. Motors: NEMA standard open drip-proof, totally enclosed fan cooled or explosion proof enclo- sures. Rugged ball bearing design for continuous duty under all operating conditions. Materiales Superiores de Construcción: Componentes completos para manejo de líqui- dos en acero inoxidable AISI 316L y consola para el montaje para resistencia a la corrosión, apariencia de calidad, y fuerza y ductilidad mejoradas. Impulsor de Eficiencia Supe- rior: El impulsor encerrado con un diseño único de anillo del sello flotante, mantiene sin ajustes, la eficiencia máxima sobre la vida de la bomba. Características de la Carcasa y del Adaptador: Construcción en acero inoxidable con NPT roscado, conexiones centrales, válvulas de fácil acceso, conexiones de cebado y drenaje con enchufes de acero inoxid- able. Cara del sello válvula/chorro opcional disponible. Sello Mecánico: Estándar John Crane Tipo 21 con carbón en con- traste con caras de silicón-carbide, elastómeros de Viton, y partes metálicas de acero inoxidable 316. Sellos de alta temperatura y productos químicos están dis- ponibles. Motores: Estándar NEMA a prueba de goteo, ventilador totalmente encerrado o recintos a prueba de explosión. Diseño robusto de balineras de bolas para trabajo continuo en todas las condiciones de funcionamiento. Las diferentes versiones de la NPE se identifican con un número de código del producto en la etiqueta de la bomba. Este número es también el número del catálogo para la bomba. El significado de cada dígito en el número de código del producto se muestra a la izquierda. The various versions of the NPE are identified by a product code number on the pump label. This number is also the catalog number for the pump. The meaning of each digit in the product code number is shown at left. Example Product Code, Ejemplo Código del Producto NPE Product Line Numbering System Línea de Producto NPE Sistema de Numeración 1 ST 2 C 1 A 4 F Seal Vent/Flush Option,Opción de Sello Válvula/ChorroSeal Ven Mechanical Seal and O-ring 4 = Pre-engineered standard For optional mechanical seal modify catalog order no. with seal code listed below. Sello Mecánico y Anillo ‘O’ 4 = Estándar aprobado Para sello mecánico opcional modificar el número de orden del catálogo con el código del sello anotado abajo. Impeller Option . . . No Adder Required For optional impeller diameters modify catalog order no. with impeller code listed. Select optional impeller diameter from pump performance curve. Código del Impulsor Opcional Para impulsores con diámetros opcionales modificar el número de orden del catálogo con el código del impulsor anotado. Escoger el im- pul con diámetro opcional de la curva de funcionamiento de la bomba. Driver, Conductor 1 = 1 PH, ODP 7 = 3 PH, XP 2 = 3 PH, ODP 8 = 575 V, XP 3 = 575 V, ODP 9 = 3 PH, TEFC 4 = 1 PH, TEFC Premium Eff. 5 = 3 PH, TEFC 0 = 1 PH, XP 6 = 575 V, TEFC HP Rating, HP Potencia C = ½ HP E = 1 HP G = 2 HP J = 5 HP D = ¾ HP F = 1½ HP H = 3 HP Driver: Hertz/Pole/RPM,Conductor: Hercios/Polo/RPM 1 = 60 Hz, 2 pole, 3500 RPM 2 = 60 Hz, 4 pole, 1750 RPM 3 = 60 Hz, 6 pole, 1150 RPM 4 = 50 Hz, 2 pole, 2900 RPM 5 = 50 Hz, 4 pole, 1450 RPM Material ST = Stainless steel, Acero inoxidable Pump Size, Tamaño de la Bomba 1 = 1 x 1¼ – 6 2 = 1¼ x 1½ – 6 3 = 1½ x 2 – 6 Pump Size, Tamaño de la Bomba 1 x 1¼ – 6 1¼ x 1½ – 6 1½ x 2 – 6 Diameter Diameter Diameter K – 61⁄8 – G – 515⁄16 53⁄8 H – 5½ 5 A 61⁄8 5¼ 4¾ B 5¾ 51⁄16 45⁄8 C 53⁄16 47⁄8 43⁄8 D 4¾ 45⁄8 41⁄16 E 47⁄16 4¼ 35⁄8 F 41⁄16 37⁄8 – Impeller Code,Código del Impulsor John Crane Type 21 Mechanical Seal (5⁄8” seal), Sello Mecánico John Crane Tipo 21 (sello de 5⁄8”) Seal Code, Código del Sello 2 Carbon EPR 10K18 4 Viton 316 SS 10K55 5 EPR 10K81 6 Viton 10K62SiliconCarbide Silicon Carbide Metal Part Rotary, Stationary, Elastomers, Parts, No., Rotativo Estacionario Elastómeros Partes Pieza Metálicas Número For frame mounted version, substitute the letters “FRM” in these positions. Para la versión con el armazón montado, sustituya las letras “FRM” en estas posiciones. 3 GOULDS PUMPSCommercial Water Performance Coverage (60 Hz) Alcance de Funcionamiento (60 Hz) NoTES: Not recommended for operation beyond printed H-Q curve. For critical application conditions consult factory. Not all combinations of motor, impeller and seal options are available for every pump model. Please check with G&L on non- cataloged numbers. All standard 3500 RPM ODP and TEFC motors supplied by Goulds Pumps, have minimum of 1.15 service factor. Standard catalog units may utilize available service factor. Any motors supplied other than Goulds Pumps check avail- able service factor. NOTAS: No se recomienda para funciona- miento superior al impreso en la curva H-Q. Para condiciones de aplicaciones críticas consultar con la fábrica. No todas las combinaciones de las opciones de motor, impulsor y sello están disponibles para cada modelo de bombas. Por favor verifique con G&L en los números no catalogados. Todos los motores estándar de 3500 RPM, ODP (abiertos resguardados) y TEFC (totalmente encerrados con enfriamiento forzado) provistos por Goulds Pumps tienen un factor mínimo de servicio de 1,15. Las unidades estándar de catálogo pueden utilizar el factor de servicio disponible. Verificar el factor de servicio disponible de todo motor no provisto por Goulds Pumps. CAPACITY (CAPACIDAD) Q METERSMETROS FEETPIES TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H0 160 140 120 100 80 60 40 20 50 40 30 20 10 0 0 20 40 60 80 100 120 140 160 U.S. GPM 0 5 10 15 20 25 30 35 m3/hr 2ST11⁄4" x 11⁄2" – 63⁄4–5 HP3500 RPM 1ST1" x 11⁄4" – 61⁄2–3 HP3500 RPM 3ST11⁄2" x 2" – 61–5 HP3500 RPM 3ST 1750 RPM2ST 1750 RPM 1ST1750 RPM 4 GOULDS PUMPSCommercial Water NPE Close Coupled Pump Major Components: Materials of Construction Bomba Cerrada Acoplada NPE Componentes Principales: Materiales de Construcción 184A 108A Seal Face Vent/Flush Option, Opción Cara del Sello Válvula/Chorro Item No., Description, Materials, Parte No. Descripción Materiales 100 Casing; Carcasa 101 Impeller; Impulsor AISI 316L SS; 108 Motor adapter; Adaptador del motor AISI 316L 108A Motor adapter seal vent/flush; Acero inoxidable Sello válvula/chorro del adaptador del motor 123 Deflector; Deflector BUNA-N 184 Seal housing; Alojamiento del sello AISI 316L SS; 184 A Seal housing seal vent/flush; AISI 316L Sello válvula/chorro del alojamiento del sello Acero inoxidable347 Guidevane; Difusor 349 Seal ring, guidevane; Anillo del sello, difusor Viton 370 Socket head screws, casing; AISI 410 SS; Encajes cabezas de tornillos, carcasa AISI 410 Acero inoxidable 371 Bolts, motor; Plated steel; Tornillos, motor Acero chapeado 383 Mechanical seal; Sello mecánico **see chart, ver tabla 408 Drain and vent plug, casing; AISI 316L SS; Enchufes de drenaje y válvula, carcasa AISI 316L Acero inoxidable 412B O-ring, drain and vent plug; Viton (Standard, estándar) Anillo ‘O’, enchufe de drenaje y válvula 513 O-ring, casing; Anillo ‘O’, carcasa EPR (Optional, Opcional) Motor NEMA standard, 56J flange; Motor NEMA estándar, brida 56J 100 101 347 370 513 184 108 383 123 349 412B 408 371 1½, 2 and 3 HP 1½, 2 y 3 HP ½, ¾ and 1 HP ½, ¾ y 1 HP Footed motor for 5 HP ODP and TEFC, all explosion proof motors, see page 13. Motor con pie para 5 HP ODP y TEFC, a prueba de explosiones motores, en la página 13. 5 GOULDS PUMPSCommercial Water NPE Frame Mounted Pump Major Components: Materials of Construction Bomba NPE de Armazón Montado Componentes Principales: Materiales de Construcción Item No., Description, Materials, Parte No. Descripción Materiales 100 Casing; Carcasa 101 Impeller; Impulsor AISI 316L SS; 108 Adapter; Adaptador AISI 316L 108A Motor adapter seal vent/flush; Acero inoxidable Sello válvula/chorro del adaptador del motor 109 Bearing cover; Cubierta de balineras Cast iron; Hierro fundido 112 Ball bearing (outboard); Steel; Balineras de bolas (exterior) Acero 122 Shaft; Eje AISI 316 SS; AISI 316 Acero inoxidable 138 Lip-seal (inboard); Sello cubierto (interior) BUNA/steel; BuNA/acero 139 Lip-seal (outboard); Sello cubierto (exterior) BUNA/steel; BuNA/acero 168 Ball bearing (inboard); Steel; Balineras de bolas (interior) Acero 184 Seal housing; Alojamiento del sello AISI 316L SS; 184 A Seal housing seal vent/flush; AISI 316L Acero inoxidable Sello válvula/chorro del alojamiento del sello 228 Bearing frame; Armazón de balineras Cast iron, Hierro fundido Item No., Description, Materials, Parte No. Descripción Materiales 304 Impeller locknut; Contratuerca del impulsor AISI 316 SS; 347 Guidevane; Difusor AISI 316 Acero inoxidable 349 Seal ring, guidevane; Anillo del sello, difusor Viton 361 Retaining ring; Anillo de retención Steel; Acero 370 Socket head screws, casing; AISI 410 SS; Encaje cabeza del tornillo, carcasa AISI 410 Acero inoxidable Hex head screw, bearing cover; Plated steel; 370C Tornillo de cabeza hexagonal, Acero chapeado cubierta de balineras Hex head screw, bearing frame; Plated steel; 371 Tornillo de cabeza hexagonal, Acero chapeado armazón de balineras 383 Mechanical seal; Sello mecánico **see chart; ver tabla 400 Shaft key; Llave del eje Steel; Acero 408 Drain and vent plug, casing; AISI 316 SS; Enchufes de drenaje y válvula, carcasa AISI 316 Acero inoxidable 412B O-ring, drain and vent plug; Viton (Standard, estándar) Anillo ‘O’, enchufe de drenaje y válvula 513 O-ring, casing; Anillo ‘O’, carcasa EPR (Optional, Opcional) Seal Face Vent/Flush Option, Opción Cara del Sello Válvula/Chorro 228371138 408 412B 304 383 349 101 100 347 370 513 184 108 168 122 112 370C 361 109 139 184A 108A 6 GOULDS PUMPSCommercial Water Performance Curves – 60 Hz, 3500 RPM Curvas de Funcionamiento – 60 Hz, 3500 RPM Ordering Standard Code, HP Rating, Imp. Código Estándar HP Dia. de Pedido Potencia E ½ 47⁄16” D ¾ 4¾ C 1 53⁄16 B 1½ 5¾ A 2 61⁄8 m3⁄ hr 0 20 40 60 80 100 120 140 0 10 20 30 40 50 6050403020100 1050 160 Model NPE / 1ST Size (Tamaño) 1 x 11⁄4-6 RPM 3500 Curve (Curva) CN0231R01 NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q. Impeller Selections for Exp. Proof Motors Selecciones del Impulsor para Motores Exp. Proof 45 48 50 50 48 51 5152 53 1⁄2 HP 10' 8’6' 5' 12' EFF % 3⁄4 HP 11⁄2 HP 1 HP 2 H P 8' 10'12' U.S. GPM 3 H P B 53⁄4" C 53⁄16" D 43⁄4" E 47⁄16" F 41⁄16"Spec. A 61⁄8" DIA. METERSMETROS FEETPIES TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) HCAPACITY (CAPACIDAD) Q NPSHR – FEET (PIES) m3⁄ hr Model NPE / 1ST Size (Tamaño) 1 x 11⁄4-6 RPM 3500 Curve (Curva) CN0231R01 0 20 40 60 80 100 120 140 0 10 20 30 40 50 METERSMETROS FEETPIES TOTAL DYNAMIC HEAD (CARGA DINAMICA TOTAL) H6050403020100 1050CAPACITY (CAPACIDAD) Q U.S. GPM 45 48 50 50 48 51 5152 53 1⁄2 HP 10' 8'6'5' 12' EFF % NPSHR – FEET (PIES) 160 3⁄4 HP 11⁄2 HP1 HP 2 HP 3 H P A 61⁄8" DIA. B 53⁄4" C 53⁄16" D 43⁄4" E 47⁄16" NOTE: Not recommended for operation beyondprinted H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q. Impeller Selections for ODP & TEFC Motors Selecciones del Impulsor para Motores ODP & TEFC Ordering Standard Code, HP Rating, Imp. Código Estándar HP Dia. de Pedido Potencia F ½ E ¾ 47⁄16 D 1 4¾ C 1½ 53⁄16 B 2 5¾ A 3 61⁄8 41⁄16”spec. NoTE: Although not recommended, the pump may pass a 1⁄16” sphere. NOTA: Si bien no se reco- mienda, la bomba puede pasar una esfera de 1⁄16”. NoTE: Although not recommended, the pump may pass a 1⁄16” sphere. NOTA: Si bien no se recomienda, la bomba puede pasar una esfera de 1⁄16”. 14 GOULDS PUMPSCommercial Water 41⁄4 X 51⁄4 2 FILL AND VENTCARGA Y VÁLVULA Y DISCHARGEDESCARGA L 31⁄4 1⁄2 4 HOLES 3⁄8 DIA.4 AGUJEROS 3⁄8 DIA. SUCTIONSUCCIÓN KEYWAY 3⁄32 x 3⁄16CHAVETERO 3⁄32 x 3⁄162 DRAINDRENAJE 2 4 311⁄16MAX. W 9⁄16 7/8 CP MAX. 41⁄2 413⁄16 NPE Frame Mounted – Dimensions, Weights and Specifications NPE Armazón Montado – Dimensiones, Pesos y Especificaciones Motor specifications: T-frame single and three phase. Open drip-proof, TEFC or explosion proof enclosures are available for 60 Hz, 3500 and 1750 RPM operation. For three phase motors, overload protection must be provided in starter unit. Starter and heaters must be ordered separately. Capacities to: 85 GPM (322L/min) at 1750 RPM 170 GPM (643L/min) at 3500 RPM Heads to: 39 feet (12 m) at 1750 RPM 150 feet (47 m) at 3500 RPM Working pressures to: 125 PSIG (9 bars) Maximum temperatures to: 250°F (121°C) Direction of rotation: Clockwise when viewed from motor end. Motores: Armazón T- monofásico y trifásico. A prueba de goteo, TEFC o recintos a prueba de explosión están disponibles para funciona- miento de 60 Hz, 3500 y 1750 RPM. Para motores trifásicos se debe de proporcionar la protección térmica contra sobrecarga en la unidad de arranque. El arrancador y los calentadores se deben pedir por separado. Capacidades: 85 GPM (322L/min) a 1750 RPM 170 GPM (643L/min) a 3500 RPM Cargas: 39 pies (12 m) a 1750 RPM 150 pies (47 m) a 3500 RPM Presión de trabajo: 125 PSIG (9 baras) Temperatura máxima: 250°F (121°C) Dirección de rotación: En dirección de las agujas del reloj visto desde el extremo final del motor. Specifications Especificaciones FILL AND VENTCARGA Y VÁLVULA 41/4 DISCHARGEDESCARGA 4 HOLES 3⁄8 DIA.4 AGUJEROS 3⁄8 DIA. SUCTIONSUCCIÓN DRAINDRENAJE YW 31/2 C. MAX.SPACER COUPLING (ACOPLE DEL ESPACIADOR) COUPLING GUARDGUARDA ACOPLE LOCATION FORSINGLE PHASE ONLYUBICACIÓN PARAMONOFÁSICOS SOLAMENTE KEYWAY 3/32 X 3/16CHAVETERO 3/32 X 3/16 2 7/8X HD HG 4 311/16MAX. HL HF HB HPHEHE HA CP 77/8 MAX. 31/8 MAX. NPE-F 15 GOULDS PUMPSCommercial Water Dimensions and Weights – Determined by Pump, Dimensiones y Pesos – Determinados por la Bomba Dim. “HL” Determined by Pump and Motor, Dim. “HL” Determinadas por la Bomba y el Motor Suct. NPT, Disch. NPT, Succión Descarga NPT NPT 1ST 11⁄4 1 1215⁄16 67⁄16 35/16 43⁄8 2 221⁄2 49⁄16 67⁄16 2ST 11⁄2 11⁄4 41⁄2 3ST 2 11⁄2 45⁄8 Pump,Bomba CP L W X Y Wt.,Peso 56 1⁄2 – 11⁄2 1⁄2 – 11⁄2 1⁄2 – 1 1⁄2 – 1 13 45 143T — — 11⁄2 11⁄2 133⁄8 45 145T 2 2 11⁄2 – 3 11⁄2 – 2 141⁄4 52 182T 3 3 5 3 165⁄8 63 184T 5 5 — 5 181⁄8 112 3500 RPM Horsepower, Fuerza Single Phase, Monofásicos Three Phase, Trifásicos ODP TEFC ODP TEFC FrameSize,Tamaño del Armazón Available Motor and Bedplate Dimensions and Weights, Pesos y Dimensiones Disponibles de la Fundación y del Motor 56 143T 8 26 67⁄8 31⁄8 223⁄8 23⁄8 1 30 1” 145T 182T 184T Shims, Deflec- tor Wt.Max.,Peso Máx. C Max. NOTES:1. Pump will be shipped with top vertical discharge position as standard. For other orientations, remove casing bolts, rotate discharge to desired position, replace and tighten 6mm bolts to 5 – 6 lbs.-ft. 2. Motor dimensions may vary with motor manufacturers. 3. Dimensions in inches, weights in pounds. 4. For explosion proof motor dimensions consult factory for information. 5. Not to be used for construction purposes unless certified. NOTAS: 1. Las bombas se transportarán con la descarga vertical superior como estándar. Para otras orien- taciones, retirar los tornillos de la carcasa, rotar la descarga a la posición deseada, y reemplazar y apretar los tornillos de 6mm a 5 – 6 libras-pies. 2. Las dimensiones del motor puede que varíen con los fabricantes. 3. Dimensiones en pulgadas, pesos en libras. 4. Para las dimensiones de los motores a prueba de explosión consultar con la fábrica para información. 5. No usar para propósitos de construcción sin certificar. HA HB HD HE HF HG HP Wt.Max.,PesoMáx 131⁄2 7 33⁄4 21/8 23 51⁄8 7 10 26 71⁄4 33⁄4 24 23⁄4 7⁄8 43 — Frame, Armazón Motor Frame,Armazón del Motor 56 140 180 Dimensions and Weights Dimensiones y Pesos