Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A17-0029_Cut Sheets Vail Cascade_1496166300.pdf
Gamewell Velociti® Series FIRECONTROL ASD-PL2F, ASD-PTL2F FC I INSTRUMENTS by Honeywell and ASD-PL2FR Description Analog, Addressable Photoelectronic Smoke Sensor The Gamewell-FCI Velociti® Series, analog address- able plug-in smoke sensors with integral communica- 4 tion provide features that surpass conventional ``. sensors. Sensitivity can be programmed in the con- trol panel software, and is continuously monitored and reported to the panel. Point ID capability allows off et • each sensor's address to be set, providing exact locations for selective maintenance when the cham- ber contamination reaches an unacceptable level. ASD-PL2F/ASD-PTL2F ASD-PL2FR The ASD-PL2F photoelectric sensor's unique optical sensing chamber is engineered to sense smoke pro- Features duced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed-tern- • Sleek, low-profile design perature thermal sensing on the ASD-PTL2F model. • Visual rotary, decimal switch addressing (01-159) • Built-in functional test switch activated by an external The Velociti® Series use a communication protocol magnet that substantially increases the speed of communica- • Bicolor LEDs flash green whenever the sensor is tion between the sensors and certain Gamewell-FCI addressed,and light steady red on alarm* analog addressable fire alarm controls. These • devices operate in a grouped fashion. If one of the Optional relay, isolator, or sounder bases • devices in the group has a status change, the panel's Low standby current microprocessor stops the group poll and concen- • Analog addressable communication trates on the single device. The net effect is a • Stable communication technique with noise immunity response speed up to five times greater than earlier • Optional remote, single-gang LED Indicator(RA100Z) designs. • Compatible with Gamewell-FCI analog addressable panels Ordering Information Note:*Only the red LED is operative in panels that do not operate in Velociti®mode. Model Description ASD-PL2F Analog, addressable photoelectronic smoke sensor ASD-PTL2F Analog, addressable photoelectronic smoke sensor with thermal sensing ASD-PL2FR Analog, addressable photoelectronic smoke sensor used with the DNR duct base when An ISO 9001-2000 Company the remote test is required. SIGNALING PINE tib) Velociti•® a registered trademark of Honeyuvell International Inc. MEA UL®is a registered trademark of U dens iters Laboratories Inc. LISTED APPROVED Approved r I S1913 3023594 21302-EV0I.VI 7272-1703:0121 GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1653 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for-installation purposes,and are subject to change w thout notice.No responsibility is assumed by Gameeell-FG far their use. x©2011 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0617 Rev. I page 1 of 2 Installation Specifications ASD-PL2F plug-in sensors use a separate base to ASD-PL2F, ASD-PTL2F, ASD-PL2FR: simplify installation, service, and maintenance. A Dimensions: 2.1" (5.1 cm)height special tool allows maintenance personnel to plug-in Diameter: 4.1" (10.4cm)installed in the B501 base and remove sensors without using a ladder. 6.1" (15.5 cm)installed in the B210LP base Shipping Weight:5.2 oz. (147 g) Mount the base on a box which is at least 1.5" (3.8cm) Operating ASD-PL2F: deep. Suitable mounting base boxes include: Temperature: 32° F to 120° F(0° C to 49° C) ASD-PTL2F: • 4.0" (10.2 cm)square box 32° F to 100° F(0° C to 38° C) • 3.5" (8.9 cm)or 4.0"(10.2 cm)octagonal box UL®-Listed 0-4000 ft./min. (1,219.2 m/min.), • Single-gang box(except relay or isolator bases) Velocity Range: suitable for installation in ducts. • With B200S or B200SR base, mounted on a 4.0" Relative 10-93% (non-condensing) (10.2cm)octagonal or square box Humidity: • With B224RB or B224B1 base, mounted on a 3.5" Thermal Ratings: Fixed-temperature setpoint 135° F(57° C) (8.9 cm)octagonal box, ora 4.0"(10.2 cm)octagonal or square box Electrical Specifications NOTE: Because of the inherent supervision provided Voltage Range: 15-32 volts DC peak by the SLC, end-of-line resistors are not required. Standby Current: (max.avg.): .0003 A @ 24 VDC Wiring "T-taps" or branches are permitted for Style 4 (one communication every 5 (Class "B")wiring. seconds with LED blink enabled) Maximum Alarm- Current: .0065 A @ 24 VDC(LED)lit). Sensor Spacing Gamewell-FCI recommends that the spacing sensors Bases and Options be used in compliance with NFPA 72. B501 Plug-in sensor base without flange Dimensions: 4.1" (10.4 cm)diameter B210LP Flanged mounting base Dimensions: 6.1" (15.5cm)diameter B210LPBP Flanged mounting base bulk pack Dimensions: 6.1" (15.5cm)diameter B224RB Plug-in sensor base with auxiliary Relay Base relay, SPDT, rated 2 amps @ 30 VDC (resistive) Screw terminals: Up to 14 AWG (2.0 mm2) 2 coil latching relay 1 Form C contact UL/CSA Rating: 0.9 A @ 125 VAC, inductive 0.9 A @ 110 VDC, inductive 3 A @ 30 VDC, resistive Dimensions: 6.1" (15.5cm)diameter Maximum: 25 devices between isolator bases. B200S Intelligent sensor sounder base Dimensions: 6.875"(17.5 cm)diameter B200SR Standard sounder base, UL 8649th Edition compliant, ULC Listed Dimensions: 6.875"(17.5 cm)diameter RA100Z Remote LED Annunciator BCK-200 Black detector covers(box of 10) DNR Duct smoke housing GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1653 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9020-0617 Rev. I page 2 of 2 www.gamewell-fci.com ameweiiVelociti Series FeFIRE TRUMENTS CONTROL ' INS AMM-21F by Honeywell Description Addressable Dual Monitor Module The Gamewell-FCI Velociti® Series, addressable dual monitor module, AMM-21F, features two (2), Style B, Class e • B initiating device circuits, each with an end-of-line resistor. This module provides addresses for any device or group of devices connected to each circuit. Any alarm initiating devices with normally open (N.O.) dry contacts, such as heat detectors, 4-wire projected beam smoke detectors, 4- _ wire smoke detectors, water flow switches, tamper switches, manual stations, etc. may be installed in these circuits. AMM-21F Features The Velociti® Series use a communication protocol that substantially increases the speed of communication • Compact size allows easy installation between the sensors and certain Gamewell-FCI analog • addressable fire alarm controls.These devices operate in a Class B, Style B, initiating device circuits grouped fashion. If one of the devices in the group has a • Visual rotary, decimal switch addressing (01-159) status change, the panel's microprocessor stops the group • 40 ohm line resistance for each initiating circuit poll and concentrates on the single device.The net effect is • Accommodates any normally open contact device response speed up to five times greater than earlier • Bicolor LEDs flash green whenever the module is designs. addressed,and light steady red on alarm* *Note: Only the red LED is operative in panels that do not operate The first circuit address is set via a rotary switch. The sec- in Velociti®mode. and circuit is automatically assigned the next higher address. The module has a single panel-controlled red Specifications LED. Supervisory current: 0.0075 amp. The AMM-21F module is designed for installation in the sig- Alarm current: .0057 amp. (LED lit) naling line circuit of any Gamewell-FCI addressable control Operating temperature: 32°to 120° F(0°to 49° C) panel. The AMM-21F is designed to mount in a 4" square Relative humidity: 10 to 93% (non-condensing) junction box, 2 1/8"deep.The initiating device circuit of the Dimensions: 4 1/2" H x 4"W x 1 1/4" D AMM-21F can support a maximum line resistance of up to (11 Hx 10.2Wx3Dcm)(Mounts in a 4" 40 ohms allowing the use of linear heat detection devices. square by 21/8"deep box). End-of-line resistor: 47 K ohms Ordering Information Model Description AMM-2IF Monitor module,two circuit, Style B, Class B SIGNALING Velociti®and E3 Series°are registered trademarks of Honeywell UL ® MEA International Inc. LISTED APPROVED Approved S1949 3023594 227-03-EVd.IV 7300-1703:0107 ISO 9001 GAMEWELL-FCI QUALITY s"arEm"5 12 Clintonville Road,Northford,CT 06472-1653 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are far information only,are not intended far installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewdl-Fa for their use. ©2013 Honeywell International Inc. Alltights reserved. www.gamewell-fci.com 9020-0629 Rev. E page 1 of 1 I � Gamewell Velociti® S FIRE CONTROL INSTRUMENTS AOM-2SF by Honeywell Description Addressable Output Relay Supervised Control Module The Gamewell-FCI Velociti® Series addressable output __ supervised control module (AOM-2SF) allows a i^• A� • 1, Gamewell-FCI analog addressable fire alarm control panel 4 to switch an external power supply,such as a DC supply or """" _ © audio amplifier (up to 80 VRMs) to notification appliances. _ + The AOM-25F notification appliance circuit can be wired �•w .�.. either Class A(Style Z)or Class B (Style Y). It also super- _ qb vises the wiring to the connected loads and reports their status to the panel as NORMAL, OPEN or SHORT ik ♦ I P CIRCUIT.The module contains a panel controlled LED. AOM-2SF The Velociti® Series use a communication protocol that Features substantially increases the speed of communication between the SLC devices and certain Gamewell-FCI ana • Listed under UL®Standard 864 and UL2572 for Mass log addressable fire alarm control panels. These devices Detifon. • Designed as a compact size to allow easy installation. operate in a grouped fashion. If one of the devices in the • Includes Class A,Style Z,or Class B,Style Y notification group has a status change, the panel's microprocessor appliance circuit. stops the group poll and concentrates on the single device. • Accommodates audio amplifiers up to 80 VRMs. The net result is a superior response speed up to five • FM Listed as suitable for a releasing device service. times greater than the earlier designs. • Includes a bicolor LED that flashes green whenever the module is addressed, and lights steady red upon The AOM-25F module is designed for installation in the activation*. signaling line circuit of any Gamewell-FCI analog address- *Note: Only the red LED is operative in panels that do not operate in able fire alarm control panel. The signaling line circuits of Velociti®mode. Gamewell-FCI analog addressable fire alarm control pan- els are designed to accommodate up to 159 modules per Specifications circuit. The AOM-2SF is designed to mount in a 4" (10.16 cm)square junction box 2 1/8"(5.5 cm)deep. Supervisory Current: .000375 amps Table 1 lists the relay contact ratings. Alarm Current: .0065 amps Current Maximum Load Operating Temperature: 32°to 120° F(0°to 49°C) Rating Voltage Description Application Relative Humidity: 10 to 93% relative humidity 3A 30 VDC Resistive Non-Coded (non-condensing) 2A 30 VDC Resistive Coded Dimensions: 4 1/2"H x 4"W x 1 1/4" D 0.9A 110 VDC Resistive Non-Coded (11.4 H x 10.2 W x 3.2 D cm) 0.5A 125 VAC Resistive Non-Coded Ordering Information 0.5A 30 VDC Inductive (L/R=5ms) Coded 1A 30 VDC Inductive(L/R=2ms) Coded Part Number Description AOM-2SF Addressable output supervised 0.5A 125 VAC Inductive(PF=.35) Non-Coded 0.7A 75 VAC Inductive Non-Coded control module SIGNALING Table 1: Relay Contact Ratings Velociti®is a registered trademark of Honeywell International Inc. L ® MEA sOa a®is a registered trademark of Underwriters Laboratories Inc. LISTED APPROVED Approved •' S1949 3023594 227-03-E VoI.IV 7300-1703:0102 iso 9001 GAMEWELL-FCI ENGINEERING QUALITY SYSTEMS MANUFACTURING SEES12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2014 Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0627 Rev.G page 1 of 1 Gamewell Velociti Series mi FCI INS FIRE TRUMENTS CONTROL AO M-2R F by Honeywell Description Addressable Output Relay Control Module The Gamewell-FCI Velociti® Series, addressable output , relay control module (AOM-2RF) allows an Gamewell-FCI 4, • % I* analog addressable fire alarm control to switch discrete relay contacts by code command. The relay provides two iu . o (2), isolated sets of Form-C contacts which transfer simul- taneously. Circuit connections to the relay contacts are not supervised by the module. The Velociti® Series use a communication protocol that 46 • substantially increases the speed of communication .^ _ - between the sensors and certain Gamewell-FCI analog addressable fire alarm controls.These devices operate in a ACN1-2RF grouped fashion. If one of the devices in the group has a Features status change, the panel's microprocessor stops the group poll and concentrates on the single device.The net effect is response speed up to five times greater than earlier • Two(2)sets of Form"C"contacts designs. • Visual rotary, decimal switch addressing (01-159) • Bicolor LEDs flash green whenever the sensor is The AOM-2RF Module is designed for installation in the addressed, and light steady red on alarm* signaling line circuit of any Gamewell-FCI analog address- able fire control panel. The module contains a panel con- • trolled LED. The AOM-2RF is designed to mount in a 4" Note: Only the red LED is operative in panels that do not operate square junction box 2 1/8"deep. in Velociti®mode. Specifications Relay Contact Ratings Supervisory current: .000375 amps. Current Maximum Load Alarm current: .0065 amps. Rating Voltage Description Application Operating temperature: 32°to 120° F(0°to 49° C) 3A 30 VDC Resistive Non-Coded Relative humidity: 10 to 93% relative humidity 2A 30 VDC Resistive Coded (non-condensing) 0.9A 110 VDC Resistive Non-Coded Dimensions: 4 1/2" H x 4"W x 1 1/4" 0.5A 125 VAC Resistive Non-Coded (11.4x 10.2 x3.2 cm) 0.5A 30 VDC Inductive Coded Ordering Information (L/R=Sms) 1A 30 VDC Inductive Coded Model Description (L/R=2ms) AOM-2RF Addressable output relay control module 0.5A 125 VAC Inductive Non-Coded (PF=.35) An ISO 9001-2000 Company 0.7A 75 VAC Inductive Non-Coded SIGNALING Velociti®Series is a registered trademark of Honeywell International Inc. ® ® MEA I LISTED APPROVED Approved I S1949 3023594 227-03EVd.IV 073060694178 GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1653 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FG for their use. x©2011 Honeywell Intematicnal Inc. Al rights reserved. www.gamewell-fci.com 9020-0625 Rev. D1 page 1 of 1 GameweII Velociti® Series FIRE CONTROL ' INSTRUMENTS B200sR_LF by Honeywell Description Low Frequency Intelligent The Gamewell-FCI, B200SR-LF sounder base sets a new Sounder Base standard for performance, installation and aesthetics. The B200SR-LF low frequency sounder base is designed to comply with the NFPA 72 sleeping space requirement to produce a fundamental frequency of 520 Hz+/ 10%with a - • square wave or its equivalent. Studies show that a lower frequency, centered around 520 Hz, is the ideal frequency _ • to awaken sleeping occupants, even those occupants with mild to severe hearing loss. In addition, it offers maximum j flexibility in installation, configuration and operation to com- cix k ))) ply or exceed the UL Standards 268 and 464 requirements. ` ' U • F The B200SR sounder base is compatible with the B501 BH • Series sounder base installations. By removing the jumper, the device enables users to select one of two B501-sup- ported tones(ANSI Temporal 3 or Continuous). Installation --- The sounder base offers the following installation features: B200SR-LF • Pre-wired mounting plate that fits various junction box sizes. Features • The housing locks to a mounting plate with two retaining screws to prevent tamper resistance. • Complies with UL Standard 464 for 520 Hz. low Specifications frequency. • Complies with UL Standard 268. Physical Specifications: • Supports 520 Hz+/- 10%square wave tone. Base Diameter: 6.875"(17.46 cm) • Includes a tone selection via an onboard jumper. Base Height: 2.0"(5.08 cm)less sensor • Compatible with the B501 BH-Series sounder base Shipping Weight: 0.60 lb.(272 gm) installations. Operating For applicable sensor Operat- • Includes a pre-wire mounting plate that fits various Temperature Range: ing Temperature Range, refer junction box sizes. to the Base/Sensor Cross Ref- • Offers a mechanical locking feature that prevents the erence Chart at the link: removal of an attached sensor head. www.systemsensor.com Operating Humidity 10%to 93% relative humidity Range: (non-condensing) Ordering Information Electrical Specifications: External Supply Voltage: 16 to 33 VDC(VFWR) Part Number Description External Supply Standby B200SR-LF Low Frequency Intelligent Current: 1 mA maximum Addressable Sensor Sounder Base Alarm Current: 65 mA max. @ 33.0 VDC 90 mA max. @ 24.0 VDC Note: The B2�00SR-LF sounder base is compatible with sR 125 mA max. @ 16.0 VDC the E3 Serieand S3 Series TM fire alarm control panels. SLC Operating Voltage: 15 to 32 VDC SLC Standby Current: Refer to applicable sensor specification Sound Output: High Volume: Greater than 85 dBA minimum measured in a UL reverberant room at 10 ft. 24 Volts(in con- SIGNALING tinuous tone) E3 Series is a registered trademark and the S3 SeriesTM is a trademark of Honeywell Inter120 - national Inc. LISTED UL®is a registered trademark of Underwriters Laboratories Inc. S1911 (ISO 9001 GAMEWELL-FCI "UALITY SYSTEMS YS°TURING EMS 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel: (203)484-7161 •Fax: (203)484-7118 QUALITY sysrFrws Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2014 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9021-60843 Rev.A page 1 of 1 •� TM ' Gamewell InnovairFlerm FIRE C�NTR�L FCI INSTRUMENTS DNR/DNRW Duct by Honeywell Smoke Housing Description Intelligent Non-Relay The InnovairFlexTM Series, DNR intelligent, non-relay pho Photoelectric Duct Smoke Housing toelectric duct smoke detector, and the DNRW watertight, ~" non-relay photoelectric duct smoke detector feature a piv `� 1. oting housing that fits both square and rectangular foot- �. i } prints.These detectors are capable of mounting to a round 1; 4. - or rectangular duct. The DNR/DNRW detectors can be E m �= i I f . F• used with the E3 Series®and 7100 Series Systems. L �, \ . Note: The InnovairFlexTM Series, DNR requires the Veloc- • '� �1 _ iti® Series, ASD-PL2FR Sensor and AOM-2RF, if relays -\'` ` . - are required for the fan control. InnovairFlex DNR/DNRW The DNRW duct smoke detector,with its NEMA 4 rating, is Listed as a watertight enclosure providing protection Features against falling dirt, rain, and windblown dust,splashing and • Photoelectric, integrated low-flow technology hose directed water.These features allow operators to use • Air velocity rating from 100 ft/min to 4,000ft/min the detector in the most extreme environments. (0.5m/s to 20.32m/sec) • The units sense smoke in the most challenging conditions, Versatile mounting options: square or rectangular operating in airflow speeds of 100 to 4,000 feet per minute, configuration temperatures of-4°F to 158°F, and a humidity range of 0 to • Broad ranges for operating temperature(-4°F to 158°F) 95 percent(non-condensing). and humidity(0%to 95% non-condensing) • Patented sampling tube installs from front or back of the An improved cover design isolates the sensor head from detector with no tools required the low-flow feature for simple maintenance. A cover tam- • New Cover tamper signal per feature was added to indicate a trouble signal for a • Increased wiring space with a newly added 3/4-inch removed or improperly installed sensor cover. The conduit knockout InnovairFlex housing provides a 3/4-inch conduit knockout • Available space within housing to accommodate the and ample space to facilitate easy wiring and mounting of the relay module. mounting of the relay module • Easily accessible code wheels on sensor head (sold The InnovairFlex duct smoke detector can be customized separately) to meet local codes and specifications without additional • Clear cover for convenient visual inspection wiring. The new InnovairFlex product line is compatible • UL®268A Listed with all previous Innovair models, including remote test • Remote testing capability accessories. • Requires SLC line power only WARNING:Duct smoke detectors have specific limitations. • NEMA Type 4 UL Listed for non-hazardous indoor and DUCT SMOKE DETECTORS ARE: outdoor applications(DNRW only) NOT a substitute for an open area smoke detector, • UV Resistant, UL®Listed housing and cover material NOT a substitute for early warning detection, and NOT a (DNRW only) replacement for a building's regular fire detection system. Refer to NFPA 72 and 90A for additional duct smoke SIGNALING POP detector 2911 application information. E3 Series®and Velociti®are registered trademarks and InnovairFlex TM is a ® MSFM011D trademark of Honeywell International,Inc. LISTED APPROVED 2202 writ uL®is a registered trademark of Underwriters Laboratories Inc. S911 3029700 2207 7272-1703:0121 S911 ISGAMEWELL-FCI TR IiY SYSTEMS 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax: (203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change vvithout notice.No responsibility is assumed by Gamewall-Fa for their use. C2013byFbneyvvdlInternational Inc, CJI rights reserved. www.gamewell-fci.com 9021-60475 Rev.E page 1 of 4 Architectural/Engineering Specifications The air duct smoke detector shall be a System Sensor InnovairFlexTM DNR Intelligent Non-Relay Photoelectric Duct Smoke Detector and DNRW Watertight NEMA4 Duct Smoke Detector. The detector housing shall be UL Listed per UL 268A specifically for use in air handling systems. The flexible housing of the duct smoke detector fits both square and rectangular footprints. The detector shall operate at air velocities of 100 ft/min to 4,000 ft/min (0.5 m/sec to 20.32 m/ sec). The unit shall be capable of providing a trouble signal in the event that the sensor cover is removed or improperly installed. It shall be capable of local testing via magnetic switch or remote testing using the RTS151KEY remote test station. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. Physical Specifications Size: Rectangular Dimensions: 14.38 in (37 cm) Length; 5 in (12.7 cm)Width; 2.5 in (6.6 cm) Depth Square Dimensions: 7.75 in (19.7 cm) Length; 9 in (22.9 cm)Width; 2.5 in (6.35 cm) Depth Weight: 1.6 lb (0.73 kg) Environmental Rating: NEMA4 (DNRW only) Operating Temperature Range: —4° to 158°F (-20° to 70°C) Storage Temperature Range: —22° to 158°F (-30° to 70°C) Operating Humidity Range: 0% to 95% relative humidity non-condensing Air Duct Velocity: 100 to 4000 ft/min (0.5 to 20.32 m/sec) DCOIL- (if included) 17.5-26.4 VDC .95mA max. Electrical Ratings For information on the electrical specifications, refer to the InnovairFlex DNR Duct Smoke Detector Installation Instructions, P/N 156-3051-001R. Accessory Current Loads at 24 VDC Device Standby Trouble RA100Z 0 mA 12 mA Max. RTS151/RTS151KEY 0 mA 12 mA Max. Installing the InnovairFlex Sampling Tube The InnovairFlex sampling tube may be installed from the front or back of the detector. The tube locks securely into place and can be removed by releasing the front or rear locking tab. (Figure 3 illustrates the front locking tab). 1 1 Mir r Figure 1 Figure 2 Figure 3 GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9021-60475 Rev. E page 2 of 4 www.gamewell-fci.com Wiring for Intelligent Non-Relay Duct Smoke Detector -----I r I I COMM. _Irop..0 LINE (+) LINE I I COMM. q-44— LINE(-) -1-11111"0 I I I I I I UL/FM LISTED 1ST 2ND CONTROL DETECTOR DETECTOR PANEL IN LOOP IN LOOP Figure 4 System Wiring Diagram for DNR + RA I (+) RA100Z - RA ■ REMOTE ALARM LED OPTION 1 PER UNIT Figure 5 DNR to RA100Z DNR TO RTS451/RTS451 KEY/RTS151/ RTS151 KEY WTH"R"REMOTE TEST CAPABLE DETECTOR HEAD OPTION: TEST COIL+ RTS451/RTS451 KEY TESTCQL+ FXI9dJaL 4 5 TEST COIL- ® RTS151/RTS15I KEY TEST CCIL- ATXP COMM+ ® C ]VIVI+a A OUT(COW ONLY)+ ® CUT(CQW/CNLY)+ OC IVw��y�� �j} RT151/RTS15IKEY COMM- ® ' ------ REMOTE TEST STATION RA/RTS R�4liZT5 ® LED oP11oN JUMPER RA+Fus 1 PER UNIT RA+ ® +� - TEST COIL OPTION RTS+ ® 1 PER UNIT 5 95mA CURRENT DRAW Figure 6 DNR to RTS151/RTS151 Key Important Notes: • The use of either RTS151 or RTS151 KEY requires the installation of an accessory coil, DCOIL, sold separately. For additional information, refer to the DNR or DNRW Duct Smoke Detector Installation Instructions, P/N 156-3051-001R and the Duct Application Smoke Detectors Application Guide. • The RTS151/RTS151KEY test coil circuit requires an external 24 VDC power supply which must be UL Listed. GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 www.gamewell-fci.com 9021-60475 Rev. E page 3 of 4 Accessories System Sensor provides system flexibility with a variety of accessories, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accesso- ries are UL Listed. f • • Figure 7 RTS151 UL S2522 Figure 8 RS2522TS151 KEY UL Figure 9 RA100Z UL S2522 Figure 10 ASD-PL2FR Ordering Information Part Number Description DNR Intelligent non-relay photoelectric low-flow duct smoke detector DNRW Watertight intelligent non-relay photoelectric low-flow duct smoke detector ASD-PL2FR Intelligent photoelectric smoke sensor with remote test capability in duct applications Accessories Part Number Description DCOIL Remove test coil required with RTS151/RTS151151 KEY DST1 Metal sampling tube duct width up to 1 ft (0.3m) DST1.5 Metal sampling tube duct widths 1 ft to 2 ft (0.3 to 0.6 m) DST1.5 Metal sampling tube duct widths 1 ft to 2 ft (0.3 to 0.6 m) DST3 Metal sampling tube duct widths 2 ft to 4 ft (0.6 to 1.2 m) DST5 Metal sampling tube duct widths 4 ft to 8 ft (1.2 to 2.4 m) DST10 Metal sampling tube duct widths 8 ft to 12 ft (2.4 to 3.7 m) DH4000E-1 Weatherproof enclosure ETX Metal exhaust tube duct width 1ft (0.3m) M02-04-00 Test magnet P48-21-00 End cap for metal sampling tubes RA100Z/RA100ZA Remote annunciator alarm LED RTS151 Remote test station RTS151 KEY Remote test station with key lock GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9021-60475 Rev. E page 4 of 4 www.gamewell-fci.com Gamewell Velociti® Series FIRE CONTROL Fei INSTRUMENTS ATD-L2F, AID-H L2F by Honeywell Description Addressable Thermal Sensor The Gamewell-FCI Velociti® Series, addressable plug-in thermal sensors with integral communication provide fea- tures that surpass conventional sensors. Point ID capabil- ity allows each sensor's address to be set, providing exact locations for pinpointing alarm locations and for selective maintenance. ATD thermal sensors use an innovative thermistor sensing circuit to produce 135°F/57°C fixed- temperature (ATD-L2F). The ATD-RL2F provides a combi- nation 15°/minute rate-of-rise with 135° fixed thermal detection that is included in a low-profile package. The ATD-HL2F provides fixed high-temperature detection at 190°F/88°C.These thermal sensors provide cost-effective, addressable property protection in a variety of applica- tions. ATQL2F The Velociti® Series uses a communication protocol that substantially increases the speed of communication between the sensors and Gamewell-FCI analog address- Features able fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a • Sleek, low-profile design status change, the panel's microprocessor stops the group • Visual rotary switch addressing poll and identifies the single device with the status change. The net effect is response speed up to five times greater • Built-in functional test switch activated by an external than earlier designs. magnet Installation • Bicolor LEDs flash green whenever the sensor is ATD plug-in sensors use a separate base to simplify instal- addressed, and light steadily red on alarm* lation, service, and maintenance. A special tool allows • Optional relay, isolator, or sounder bases maintenance personnel to plug-in and remove sensors without using a ladder. • Low standby current • Addressable communication Mount the base on a box which is at least 1.5" (3.8 cm) deep. Suitable mounting base boxes include: • Stable communication technique with noise immunity • 4.0"(10.2 cm)square box. • Optional remote, single-gang LED accessory • 3.5"(8.9 cm)or 4.0" (10.2 cm)octagonal box. (RA-100Z) • Single-gang box(except relay or isolator base). • Suitable for installation in ducts • With B200S or B200SR base, mounted on a 4.0" (10.2 cm)octagonal or square box. Note:"Only the red LED is operative in panels that do not operate • With B224RB or B224B1 base, mounted on a 3.5"(8.9 in Velociti®mode. cm)octagonal box, or a 4.0"(10.2 cm)octagonal or square box. NOTE: Because of the inherent supervision provided by the SLC, end-of-line resistors are not required. Wiring "T- An ISO 9001-2000 Company taps"or branches are permitted for Style 4 (Class"B") wiring. SIGNALING Velociti®and E3 Series®are registered trademarks of Honeywell International Inc. ® ® MEA UL®is a registered trademark of Underwriters Laboratories Inc. LISTEDAPPROVED Approved ULC°is a registered trademark of Underwriters Laboratories Canada Inc. 23323023594 219-02-E Vol.VI 7270-1703:0115 GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FG far their use. �©2011 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0620 Rev. E page 1 of 2 Specifications Specifications ATD-L2F/ATD-RL2F Bases and Options Dimensions: 2.1" (5.3cm)Height B501 Plug-in sensor base without flange 4.1" (10.4cm)diameter installed in Dimensions: 4.1"(10.4 cm)diameter the B501 base B210LP Flanged mounting base 6.1" (15.5cm)diameter installed in Dimensions: 6.1"(15.5cm)diameter the B210LP base B210LPBP Flanged mounting base bulk pack Shipping Weight: 4.8 oz. (137 g) Dimensions: 6.1"(15.5 cm)diameter Operating B224RB Plug-in sensor base with auxiliary relay, Temperature: SPDT ATD-L2F or 2 coil latching relay 1 Form C contact UL/ ATD-RL2F —4° F to 100° F(-20° C to 38°C) CSA Rating: ATD-HL2 —4° F to 150°F (-20 C to 66°C) 0.9 A @ 125 VAC (inductive) Sensor Spacing: UL®approved for 50 ft. (15.2 m) 0.9 @ 110 VDC(inductive) center to center 3.A @ 30 VDC (resistive) FM approved for 25 x 25 ft. Dimensions: 6.1"(15.5cm)diameter (7.6 x 7.6 m)spacing B224B1 Plug-in sensor isolator base for Style 7 Relative Humidity: 10—93%(non-condensing) operation ATD-L2F Fixed-temperature setpoint Dimensions: 6.1"(15.5cm)diameter 135°F (57°C) Maximum 25 devices between isolator ATD-RL2F Combination 135° F fixed bases temperature and 15° F(8.3°c)/per B200S Intelligent sensor sounder base minute rate-of-rise° Dimensions: 6.875" (17.5 cm)diameter ATD-HL2F Fixed-temperature setpoint B200SR Standard sounder base, UL 864 9th 190°F (88°C) Edition compliant, ULC Listed Dimensions: 6.875" (17.5 cm)diameter RA-100Z Remote LED Annunciator Electrical Specifications BCK-200 Black detector covers(box of 10) Voltage Range: 15-32 Volts DC peak Ordering Information Standby Current: 200 mA @ 24 VDC (without communication) (max.avg.) .0003 A @ 24 VDC Part Number Description (one communication every 5 seconds ATD-L2F Addressable thermal sensor,fixed, 135° F with LED blink enabled) ATD-RL2F Addressable thermal sensor, combination LED Current fixed,135° F and 15°/minute rate-of-rise. (max.) .0065 A @ 24 VDC(LED lit) ATD-HL2F Addressable thermal sensor,fixed, 190° F GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9020-0620 Rev.E page 2 of 2 www.gamewell-fci.com Gamewell Velociti®Series FCI INSTRUMENTSL mes_coF by Honeywell Description Advanced Multi-Criteria Fire/CO Detector The Advanced Multi-Criteria Fire/CO Detector(MCS- COF)is an addressable device that provides both fire and carbon monoxide (CO) detection. For fire detec- tion, the detector combines the following four sepa- rate sensing elements in one unit. r� • Smoke • Carbon Monoxide (CO) • Light/flame • Heat f These elements sense multiple components of a fire. • / This approach enables an enhanced sensitivity to 1111, real fire with a heightened immunity to nuisance par- ticulate. For CO, the detector's electrochemical sens • - ing cell creates a separate signal for life safety CO • detection. - Released through the incomplete burning of various fuels, CO is a colorless, odorless and deadly gas that is virtually impossible to detect with the human MCS-COF in a B200S Sounder Base senses. Because the potential exists for dangerous levels of CO to accumulate in almost any building, Features legislation mandates the use of CO detection in com- mercial spaces in the U.S. The MCS-COF is Listed to the UL® 2075 Standard for system-connected life • Offers the unique function to detect the following safety carbon monoxide monitoring. four major elements of a fire: It is designed to be used with the Gamewell-FCI, E3 - Smoke - Carbon Monoxide (CO) Series or S3 Series fire alarm control panel only. The - Light/flame - Heat MCS-COF should be used in conjunction with the • Supplies a separate CO detection signal. B200S intelligent sounder base, which can generate • Presents the highest nuisance alarm immunity. either of the following patterns: • Produces an automatic drift compensation of • Temp 3 pattern for fire. smoke sensor and CO cell. • Temp 4 pattern for CO alarm indication. • Uses only one address on the SLC. The B200S recognizes the System Sensor synchro- • Includes the EasyTest CO testing capability. nization protocol. This feature enables it to be used • Complies with UL®Listed Standard 268 and UL® as a component of the general evacuation signal, Listed Standard 2075. along with other System Sensor horns, horn strobes, • Separates the audible signal for fire or CO alarm and chimes, when the MCS-COF is connected to a when used with the B200S Base. power supply or Fire Alarm Control Panel (FACP) • Provides the CO cell end-of-life warning and fault. output that is capable of generating the System Sen- sor synchronization pulses. With each sounder base carrying a unique address, the FACP can then com- mand an individual sounder, or a group of sounders, to activate. The command set from the panel can be tailored to the specific event, allowing selection of SIGNALING PEW volume, tone, and group. For more information on the B200S, refer to Data Sheet P/N: 9021-60671. (1G147 E3 Series®is a registered trademark of Honeywell International Inc. UL®is a registered traderrak of Underwriters Laboratories Inc. LISTED WWI S1195 7275-1703:0175 -1S0 9001GAMEWELL-FCI °"°"`"MANUFACTURING 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information cnly,are not intended for installation purposes,and are subject to change without notice.No responsibility is assured by Gamewell-FG for their use. �©2013byHoneywell International Inc. AIrights reserved. www.gamewell-fci.com 9021-60708 Rev.C page 1 of 2 Specifications Specifications (Continued) Physical Specifications CO Monitoring UL Standard Reference -Alarm Base Diameter: 6.875"(17.46 cm)installed in a B200S Thresholds are as follows: base Parts per Base Height: 3.46"(8.79 cm)installed in B200S base Million 70±5ppm 150±5ppm 400± 10ppm Shipping Weight: 4.6 oz Detector Color: Ivory Response Material: Bayblend FR110 Time, min. 60-240 10-50 4-15 Operating Note: Per UL Standard 2075,the MCS-COF has been Temperature Range:32° F to 100° F (0° C to 38° C) tested to the sensitivity limits defined in UL Standard 2034. Operating Humidity Range: 15 to 90% relative humidity (non-condensing) Ordering Information Air Velocity: 0 to 4,000 ft/min (0 to 20 m/sec) Electrical Specifications Part Number Description Operating Voltage MCS-COF Advanced Multi-Criteria Fire/CO Range: 15 to 32 VDC Detector Note: Due to the unique nature of this Maximum Standby Current: 300 pA at 24 VDC (no communica- detector, pleaseconsult your Fire Panel Control Panel Manufaacturer for tion every 5 seconds with LED blink the specific model and compatibility. enabled). Accessories: Maximum Alarm BCurrent(LED on): 7.2 mA at 24 VDC 02-0 MAddressable Sounder Base M02-04-01 Detector Test Magnet M02-09-01 Telescoping Test Magnet Sensitivity Settings & Suggested Applications Level 1: 1% per foot(30.48 cm)of smoke. Very clean environments: Used in Laboratories. Level 2: 2% per foot(30.48cm)of smoke. Clean environments: Used in offices. Level 3: 3% per foot(30.48cm)of smoke. Moderately clean environments: Used in hotel rooms, dorm rooms. Level 4: 3% per foot (30.48 cm)of smoke with different algorithm processing and weighting of sensor elements. Used in hotel rooms near a shower, boiler rooms. Level 5: 4% per foot(30.48 cm)of smoke. Used in equipment rooms, kitchens, paint shop. Level 6: Thermal alarm at 135° F (57° C). Warning:After the CO cell has reached the end-of-life,the CO sensor no longer provides life safety protection. How- ever, when the fire detector enters Photo, Thermal, Infra- red (PTIR)mode,the following sensitivities apply: Level 1: 1% per foot(30.48 cm)of smoke.Very clean environments: Used in Laboratories. Level 2: 2% per foot(30.48cm)of smoke. Clean environments: Used in offices. Level 5: 3% per foot(30.48 cm)of smoke. Moderately clean environments: Used in hotel rooms, dorm rooms. Level 6: Thermal alarm at 135° F (57° C). GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1653 USA•Tel: (203)484-7161 •Fax: (203)484-7118 9021-60708 Rev.C page 2 of 2 www.gamewell-fci.com GameweII Intelligent mi Fei INFIRE CONTROL STRUMENTS Bases by Honeywell Description B501 , B224RB, B224B1, and B210LP, The Intelligent Velociti® and CLIPTM mounting bases Mounting Kits, and Accessories and kits provide a variety of ways to install Gamewell-FCI detectors in any application. These . mounting bases are non-addressable and are avail- - able in both the Velociti and Clip protocols. The intel- ligent detectors can be mounted in any of the _. following, depending on the junction box selection .--,.-I.) _ (see Table 1 -Junction Box Selection Guide). 14 • flanged bases • flangeless bases Figure B501 Mounting Rase Figure 2 B210LP Mounting Rase • plastic rings Relay, isolator, and sounder bases can be used to meet local code requirements. Relay bases provide ,i \ ,/ �`\ one Form-C contact relay for the control of auxiliary ] F functions such as door closure and elevator recall. Isolator bases allow loops to continue to operate '.,-i under fault conditions and automatically restore when the fault is removed. Sounder bases are avail- Figure 3B224BIMounting Base Figure 4B224RBMounting Bag= able in a combination temporal 3 and continuous Features tone model. All sounder bases offer the following features. The Intelligent Bases provide a variety of mounting • Complies with UL Standards 268 and 464. options to meet your installation challenges. The • Includes the following three types of bases that bases come in flanged or flangeless versions so that comply with local code requirements: you can mount the bases to a variety of junction - Relay - Isolator boxes. See Table 1 for the Junction Box Selection - Sounder Guide. You can use the SMB600 surface mounting • Offers temporal and non-temporal pattern box to mount the following bases: versions. • B224RB relay base • B210LP relay base Relay Base Feature • B224B1 isolator base • Relay bases provide one Form-C contact relay. Isolator Base Feature Specifications • Isolator bases include data communications lines to operate under fault condition. System Temperature and Humidity Ranges: Installation Features These bases comply with the NFPA requirements for The bases offer the following flexible installation operation at 0°C to 49°C (32°F to 120°F); and at a characteristics. relative humidity(non-condensing)of 85% at 30°C • Has multiple accessory options. (86°F) per NFPA, and 93% ±2% at 32°C ±2°C • Includes an installation mounting kit and (89.6°F ± 1.1°F) per ULCe. However, the useful life accessories for several types of model options. of the system's standby batteries and the electronic • Supports 12-24 AWG gauge wire ranges to components may be adversely affected by extreme provide the bases with flexible installation. temperature ranges and humidity. Therefore, it is • Contains bases that enable quick and secure recommended that the bases and all peripherals be detectorlu in. installed in an environment with a nominal room tem- p g perature of 15°C to 27°C (60°F to 80°F) • Provides SEMS screws for easy wiring connections. SIGNALING Velociti®is a registered traderrcuk&C7ipT^is a trademark of Honeywell International Inc. el • UL®is a registered traderrerk of Undevmiters Laboratories Inc. C.at03f'.41 ULG°is a registered trademark of Underwriters Laboratories of Canada Inc. LISTED I APPROVED S911 3035027 7135-1653:0213 ISO ENGINEERING E MANUFACTURING GAMEWELL-FCI QUALITY SYSTEMS 12 Clintonville Road, Northford,CT 06472-1653 USA•Tel:(203)484-7161 •Fax: (203)484-7118 Specifications are for infonration only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Cemewell-Fa for their use. C2014HoneywellInternational Inc. All rights reserved. www.gamewell-fci.com 9021-60540 Rev. F page 1 of 2 Temperature Range: Ordering Information For B501, B224RB, B224B1, and B210LP 32°F to 120°F (0°C to 49° C) Intelligent Bases Humidity Range: 10%to 93% RH, Part Number Description non condensing B501 Flangeless mounting base Wire Gauge: Dimensions: 4.1" (10.41 cm)diameter For B224131, B224RB: 14 to 24 AWG B501BP Flangeless mounting base bulk pack Dimensions: 4.1" (10.41 cm)diameter Electrical Ratings B224B1 Isolator base Dimensions: 6.875" (17.462 cm)diameter For B224RB, B224B1: B224RB Relay base Operating Voltage: 15 to 32 VDC (powered by SLC) Dimensions: 6.875" (17.462 cm)diameter Standby Ratings: <500 pA maximum @ 24 VDC B210LP Flanged mounting base Set Time Dimensions: 6.1" (15.5cm)diameter (B224RB only): Short delay: 55-90 mseconds B210LPBP Flanged mounting base bulk pack Long delay: 6 to 9 seconds Dimensions: 6.1" (15.5 an)diameter Reset Time XR2B Detector removal tool (B224RB only): 20 mseconds maximum (T55-127-000 included). Relay XP-4 Extension pole for XR2B Characteristics (5 to 15 ft/1.524 to 4.572 m) (B224RB only): Two-coil Latching Relay T55-127-000 Detector removal head. One Form-C Contact BCK-200B Black detector kit. Ratings (UL/CSA): 0.9 A @ 125 VAC (inductive) WCK-200B White detector kit. 0.9 A @ 110 VDC(inductive) 3.0 A @ 30 VDC(resistive) Mounting Kits and Accessories Part Number Description SMB600 Surface mounting kit,flanged. F110 Accessory retrofit flange ring for B210LP F110BP Accessory retrofit flange ring for the B210LPBP bulk pack of 15. F210 Accessory with a new smaller flange ring for the B210LP. M02-04-01 Detector test magnet. M02-09-00 Test magnet with telescoping handle. Table 1 shows the Junction Box Selection Guide. Table 1: Junction Box Selection Guide 3.5" 4.0" 4.0" 4.0"Square with Single-Gang Octagonal Octagonal Square 3.0"mud ring 50 mm 60 mm 70 mm 75 mm B501 No Yes No No Yes Yes Yes Yes No B210LP Yes Yes Yes Yes Yes No No No No B224B1 No Yes Yes Yes Yes No Yes Yes Yes B224RB No Yes Yes Yes Yes No Yes Yes Yes NOTE:The box depth is contingent on the base and the wire size. For information on applicable local codes for appropriate recommendation, refer to the National Electrical Code. GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1653 USA•Tel: (203)484-7161 •Fax: (203)484-7118 9021-60540 Rev. F page 2 of 2 www.gamewell-fci.com SYSTEM �$ SENSOR • Indoor Selectable- 5 Output Speaker Strobes and Dual • , Voltage Evacuation �" Speakers for Ceiling , � Applications e„ SpectrAlerl°Advance selectable-output speaker strobes and dual-voltage evacuation speakers can reduce ground SPECTRIert faults and enable faster installation. A ins c Features The SpectrAlert Advance Series of speakers and speaker Plug-in design and protective cover reduce ground faults strobes reduce costly ground faults using a plug-in design and • universal mounting plate that allow the installer to pre-wire mounting • Universal mounting plate with an onboard shorting spring tests plates,dress the wires,and confirm wiring continuity before plugging wiring continuity before installation in the speakers. In addition,a protective plastic cover prevents • No extension ring required nicked wires by covering exposed speaker components. • Field selectable candela settings: Standard: 15, 15/75,30,75,95, 110, 115 These devices also enable faster installations by providing instant High: 135, 150, 177, 185 feedback to ensure that wiring is properly connected,rotary switches to select voltage and power settings,and 11 field-selectable candela • Automatic selection of 12-or 24-volt operation at 15 and settings for both wall and ceiling speaker strobes. 15/75 candela • Rotary switch simplifies field selection of speaker voltage(25 The low total harmonic distortion of the SP speaker offers high fidelity and 70.7 Vrms)and power settings(1/4,1/2, 1 and 2 watts) sound output while the SPV speaker offers high volume sound output • SP speakers offer high fidelity sound output for use in high ambient noise applications. • SPV speakers offer high volume sound output SpectrAlert Advance makes installation easy • Compatible with System Sensor synchronization protocol •Attach a universal mounting plate to a 4 x 4 x 21i8 inch back box. Electrical compatibility with existing SpectrAlert products Flush mount applications do not require an extension ring. • •Connect the notification appliance circuit or speaker wiring to the • Optional tamper resistant Torx head screw included terminals on the mounting plate. • Listed for ceiling or wall mounting •Attach the speaker or speaker strobe to the mounting plate by inserting the product tabs into the mounting plate grooves. Rotate the device into position to lock the product pins into the mounting plate terminals.The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. Agency Listings SIGNALING 0 111> MEA LISTED L ;_ approved S4048 7320-1653:201 10-08-E SpectrAlert Advance Speaker and Speaker Strobe Specifications Architectural/Engineering Specifications General SpectrAlert Advance speaker and speaker strobes shall mount to a 4 x 4 x 21i8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate.Also, SpectrAlert Advance speaker strobes,when used with the Sync•CircuitTM Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32°F and 120°F from a regulated DC,or full-wave rectified, unfiltered power supply.Speaker strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115, 135, 150, 177, 185. Speaker The speaker shall be a System Sensor SpectrAlert Advance model dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service.The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F.The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe combination The speaker strobe shall be a System Sensor SpectrAlert Advance model listed to UL1480 and UL 1971 and be approved for fire protective signaling systems.The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch,and shall have a frequency range of 400 to 4,000 Hz.The speaker shall have power taps that are selected by rotary switch.The strobe shall comply with the NFPA 72 requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y (class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical Specifications Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Dimensions,Ceiling-Mount SPS Speaker Strobe 6.8 in Dia.x 4.7 in D(including lens and speaker) SPSV Speaker Strobe 6.8 in Dia.x 4.8 in D(including lens and speaker) SP Speaker 6.8 in Dia.x 2.8 in D SPV Speaker 6.8 in Dia.x 2.9 in D Electrical/Operating Specifications Nominal Voltage(speakers) 25 Volts or 70.7 Volts(nominal) Maximum Supervisory Voltage(speakers) 50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage(strobes) Regulated 12 V DC/FWR or regulated 24 DC/FWR Operating Voltage Range(includes fire 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) alarm panels with built in sync) Operating Voltage with MDL Sync Module 9 to 17.5 V(12 V nominal)or 17 to 33 V(24 V nominal) Frequency Range 400 to 4,000 Hz Power 1/4,1/, 1,2 watts AVDS00701 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) 8 to 17.5 Volts 16 to 33 Volts Candela DC FWR DC FWR Standard 15 123 128 66 71 Candela Range 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 Sound Output UL Reverberant(dBA @ 10 ft.) 2W 1W '/2W 1/4 W Ceiling-Mount SPC Series 86 83 80 77 Ceiling-Mount SPCV Series 90 87 84 81 Ceiling-Mount SPSC Series 85 82 79 76 Ceiling-Mount SPSCV Series 89 86 83 80 Dimensions 6.81" - -97.x-1.96"= 6.81 " -.97=f-1 .841- ., 0 0 0 °°°8888 o° o �o�_� o,J----0 o°o°ocs eo°s°e°oo o ao 00°0 000:000000000000000° i o°o°o°00%0°o°°o°°o°o°oo°000°o°° Ai, 00009°00000000°00°000 ' oo00oo$0oe000OQ0000 Ellihi'00 '000 � oo°00000°000°oopp000000000000°oo°000000000 000I 0000000 0 0 O0p 0000000000\ :00 \00000 k0808.OoOo°00°0°°°00 I'� 000000000000000000000 °oe,c,g4i 0000, \081.0 00000 000°o°o°Oo°o°ooioc/ Igitco:0;03:1,0Y :p0 o °0°0°0° ,000000000 0000000000000oo°o°o°oo 000ao 0 0°0°°°0°0° •—•0� \000.9°000°eoo°o°o°0° °o°oo°0000°°o°°e°o°80 ::oo° ' a°�°�o°000°°°0°0' \I 000000 oO oppO°/ \I O��O o s000�� 1 ________0_____ Ceiling-Mount SPV Speaker Ceiling-Mount SP Speaker 2.83" 6.81 - 1.60""I 1.84" 0- / e°°o.008:0 o0 o eo o°00°0°0° —oe°o is o°o°°o°0 0000 op o°o o i in 000000 _ _ i 000 00°° °OOo ooioo - 000000 pp00 o ill Milo 000000 ooe000 000000 000000 000soo I ooe000 000000 000000 ill 000000 000000 __ 000ao 00000 00000 00000•, •mm 00000\ e0000 09009 \ 000°0. 000 00000: 000°000° I °000 00 000ao° .—.::::OV 00000, °°°)4°Z°100:::0°oo°apo°oo°ooa 0 a o°Opo0000c°°°o ®° Ceiling-Mount SPS Speaker Strobe AVDS00701 Surface Mounting O ��io \ '� ,� \\ o°oo°o°000000u uo o°ouu°u°°oua ou�u��u° 0°00°00 00000°°0p0°°° 0 � ] 000000 °000:0 oto °000 000°000°o°0000°a o°°o°o°°o°o°oo o°0°0°0°0°0°0 a°o°°o°000 00000000 0 f ,, °uo°oo°o°oo°o°°°°�° 0 lig lv' \to°o°o°oo°»..0009,0„00„00000000' ...,,, 0000000• 1 ® 000°0 u °00000• m ,, r\ I ,0000°°000°0°°oo°°°°. j+w A� °'°opo°°o�,„ „ .i.,...„,,„,, 111 io° °°o .4) Ceiling-Mount Speaker with SPBBSCW Back Box Ordering Information for SpectrAlert°Advance Speakers and Speaker Strobes Ceiling Mount White Red Description SPCW SPCR Speaker only SPCWV SPCRV Speaker only,High dB SPSCW" SPSCR Speaker Strobe,Standard cd SPSCWH" SPSCRH Speaker Strobe,High cd SPSCWV" SPSCRV Speaker Strobe,Standard cd,High dB SPSCWVH SPSCRVH Speaker Strobe,High cd,High dB SPSCW-CLR-ALERT — Speaker Strobe, Standard cd,Clear Lens Accessories White Red Description RFPW RFP 7 in x 9.5 in Retrofit Plate SPBBSCW SPBBSC Ceiling Mount Back Box Skirt TRCW TRC Ceiling Mount Trim Ring Notes: "Add-P to model number for plain housing(no"FIRE"marking on the cover)e.g.SPSCW-P $"Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings. $T SYSTEM ©2012 System Sensor. 3825 Ohio Avenue•St.Charles, IL 60174 Product specifications subject to change without notice.Visit systemsensor.com �$ SENSOR Phone:800-SENSOR2•Fax:630-377-6495 for current product information,including the latest version of this data sheet. AVDS00701•3/12 SYSTEM �$ SENSOR , . \,), `t rR t ) Indoor Selectable- y•= Output Strobes and ,� Horn Strobes for �� rr, •, ....... Ceiling Applications lications SpectrAlert®Advance audible visible notification products 311 are rich with features guaranteed to cut installation times SPECTR�ert and maximize profits. 6,464r A . c Features The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns,strobes,and horn strobes in the industry. • Plug-in design with minimal intrusion into the back box With white and red plastic housings,wall and ceiling mounting • Tamper-resistant construction options,and plain and FIRE-printed devices,SpectrAlert Advance • Automatic selection of 12-or 24-volt operation at 15 and can meet virtually any application requirement. 15/75 candela • Field selectable candela settings on ceiling units: 15, 15/75,30, Like the entire SpectrAlert Advance product line,ceiling-mount strobes and horn strobes include a variety of features that increase 75,95, 110, 115, 135, 150, 177,and 185 their application versatility while simplifying installation.All devices • Horn rated at 88+dBA at 16 volts feature plug-in designs with minimal intrusion into the back box, • Rotary switch for horn tone and three volume selections making installations fast and foolproof while virtually eliminating • Universal mounting plate for ceiling units costly and time-consuming ground faults. • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage,SpectrAlert Advance utilizes a universal mounting plate • Electrically Compatible with legacy SpectrAlert devices with an onboard shorting spring,so installers can test wiring • Compatible with MDL sync module continuity before the device is installed. • Listed for ceiling or wall mounting Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with three volume selections. Agency Listings SIGNALING O ® MEA 0 approved ( e LISTED APPROVED 7125-16531887125-1653:186)horn indoor strobesstrob,s) 54011(chimes,horn strobes,horns) 3023572 MEA452-05-E chime strobes) S5512(strobes) 7135-1653:189(horns,chimes) SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance strobes and horn strobes shall mount to a standard 4 x 4 x 11/-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,when used with the Sync•Circuit'""Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Back Box Skirt Dimensions(BBSC-2,BBSCW-2) 7.1"diameter x 2.2"high(180 mm diameter x 57 mm high) Ceiling-Mount Trim Ring Dimensions(sold as a 5 pack)(TRC-HS, 6.9"diameter x 0.35"high(175 mm diameter x 9 mm high) TRCW-HS) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS00501 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Strobe Tones and Sound Output Data Horn Strobe Output(dBA) 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobes. AVDS00501 SpectrAlert Advance Dimensions 7.1" 14-2.251 6.8" \ Dia. � Dia. k� ILII j__) /70 0 o ° C ,' . .,1„i 1't111.t 2 Inill i9 I IL 1 \\b ° Cy T (\r :/ C Ceiling-mount horn strobes Ceiling back box skirt SpectrAlert Advance Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2R* 2-Wire Horn Strobe,Standard cd,Red SCR Strobe,Standard cd,Red PC2RH 2-Wire Horn Strobe,High cd,Red SCRH Strobe,High cd,Red PC2W*t 2-Wire Horn Strobe,Standard cd,White SCW* Strobe,Standard cd,White PC2WH* 2-Wire Horn Strobe,High cd,White SCWH Strobe,High cd,White PC4R 4-Wire Horn Strobe,Standard cd,Red Accessories PC4RH 4-Wire Horn Strobe,High cd,Red BBSC-2 Back Box Skirt,Ceiling,Red PC4W 4-Wire Horn Strobe,Standard cd,White Back Box Skirt,Ceiling,White TRC-HS Trim Ring,Ceiling,Red TRCW- Trim Ring,Ceiling,White HS Notes: *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2R-P. t Add"-SP"to model number for"FUEGO"marking on cover,e.g.,P2R-SP. $"Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings. *Th_ SYSTEM ©2012 System Sensor. 3825 Ohio Avenue•St.Charles, IL 60174 Product specifications subject to change without notice.Visit systemsensor.com SENSOR Phone:800-SENSOR2•Fax:630-377-6495 for current product information,including the latest version of this data sheet. AVDS00501•3/12 Gamewell MS-i Series Fe' FIRE TCORUMENTSNTROL INS by Honeywell Description Non-Coded, Manual Fire Alarm Stations The Gamewell-FCI, MS-7 Series manual fire alarm sta- tions are available in a wide variety of configurations. The Stations comply with the Americans with Disabilities Act 1 J R E (ADA) 5-lb. maximum pull force requirement. Operating instructions and Braille text are engraved in the handle. All stations have a key lock/reset which is keyed alike with I USIH Gamewell-FCI fire alarm control panels and other manual r PUPLLH OOWN I fire alarm stations. MS-7AF Velociti Addressable Station The MS-7AF Velociti®Series addressable station is a dou- ble action station designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control aGariewell panels. Activation of the station causes its assigned " address to register at the control panel. The door contains I - an LED which flashes green in normal condition and lights MS-7 steady red when the station has been activated.* The sta- tion features screw terminals. Features MS-7ASF Velociti Addressable Station The MS-7ASF Velociti® Series addressable station is a • Addressable stations compatible with all Gamewell-FCI single action station designed for installation in the signal analog addressable fire alarm controls ing line circuit of Gamewell-FCI analog addressable con- trol panels. Activation of the station causes its assigned • Conventional stations suitable for use with any UL® address to register at the control panel. The door contains Listed control panel an LED which flashes green in normal condition and lights steady red when the station has been activated.* The sta- • Both single and double action stations available tion features screw terminals. • Tumbler lock for test and reset keyed alike with The Velociti® Series stations use a communication proto- Gamewell-FCI controls col that substantially increases the speed of communica- tion between the sensors and certain Gamewell-FCI • Surface or semi-flush mounting analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the • Shock and vibration resistant group has a status change, the panel's microprocessor stops the group poll and focuses on the single device. The net effect is response speed up to five times greater than • Stations(MS-7LOB)Listed for outdoor applications earlier designs. • Complies with ADA pull force requirements MS-7 Double Action Station *Only the red LED is operative in panels that do not oper- The MS-7 double action station is used with conventional ate in Velociti mode. fire alarm control panels. It features a set of single pole contacts and screw terminals for connection to an initiating circuit. An ISO 9001-2000 Company Velodti®is a registered trademark of Fbneyvtell International Inc. SIGNALING y, UL®is a registered trademark of Underwriter's Laboratories Inc. 0 is a registered trademark of GE Plastics,a subsidiary of General FNI MEA `r s: s l7edricCorrpany LISTED 67�WNII 07150.003t 261 GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for-installation purposes,and are subject to change without notice.No responsibility is armed by Gameeell-FG far their use. ©2010 by l-b eywell International Inc. Al rights reserved. www.gamewell-fci.com 9020-0616 Rev. D page 1 of 2 MS-7S Single Action Station Specifications The MS-7S single action station is used with conventional fire alarm control panels. It features a set of single pole Material: Lexan® contacts and wire leads for connection to an initiating drcuit. Contact Ratings: 0.25 amps. @ 30 VAC/VDC MS-7SP Double Action Station (resistive) The MS-7SP is a double action station similar to the MS-7 Dimensions: 5 5/8" H x 4 1/4"W x 1 1/4"D station, with the additional feature of both English and (14 x 10.1 x 3.2 cm) Spanish instructions molded into the unit. Operating Temperature MS-7LR Dual-action Agent Release Station (MS-7AF, MS-7ASF): 32°to 120° F (0°to 49° C) The MS-7LR is designed for use with the Gamewell-FCI (MS-7LOB): -30°to 150° F(-35°to 66° C) fire alarm control panels with releasing capabilities and Relative Humidity Flex Series releasing systems. It features a set of single (MS-7AF, MS-7ASF): 10 to 93% (non-condensing) pole contacts and screw terminals for connection to an ini- (MS-7LOB): 85%±5%@ 86°±3.6° tiating circuit. (30°±2° C) Alarm Current: .0030 amp. 0.007 for LED MS-7LRA Agent Release Station with Abort Supervisory Current The MS-7LRA is designed for use with the Gamewell-FCI (MS-7AF, MS-7ASF): .00030 amps. fire alarm control panels with releasing capabilities and Flex Series releasing systems where system abort capabil- ities are required. It consists of an MS-7LR mounted on a Ordering Information plate with an abort switch and LED indicators for system normal, and system activated status. Part Number Description MS-7LOB Double Action Station MS-7 Double action station (Listed for Outdoor Applications) MS-7AF** Velociti addressable double action The MS-7LOB station must be mounted on a Model SB-I/O station backbox. In retrofit applications,the station is UL Listed for MS-7ASF** Velociti addressable single action station use with the WP-10 backbox. It is intended for use with MS-7S Single action station,wire leads conventional control panels and has a set of single pole MS-7SP Double action station, English and contacts and screw terminals. Spanish instructions Mounting MS-7LR Agent release station, dual-action MS-7LRA Agent release station with abort switch, The MS-7 interior stations may be surface mounted or LED indicators, dual-action semi-flush mounted on a standard double-gang, or 4-inch MS-7LOB Double action station, outdoor use (10.2 cm)square electrical box.An optional trim ring (Includes SB-I/O- Indoor/outdoor use (BG12TR)may also be used for semi-flush mounting. backbox) NYC-Plate SB-I/O Indoor/outdoor use backbackbox The NYC-Plate provides the backplate for the manual pull SB-10 Surface backbox station. (See Figure 1). BG12TR Trim ring for semi-flush mount, plastic NY-PLATE NYC backplate for manual pull station **For use with the Gamewell-FCI analog addressable control panels only. FIRE [4.r.trozi t1=1 Figure 1 NYC-Plate GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9020-0616 Rev.D page 2 of 2 www.gamewell-fci.com