HomeMy WebLinkAboutA17-0029_FireForce8 Vail Cascade Main Bldg Lower Level East_1496166300.pdf riGamewell 1 ° v - System Current Draw - FireForce8 Total Current Standb 0.030 A Alarm 2.335 A Cl -Standby Current C2-Alarm Current Device Qty Draw Standby Qty Draw Alarm 1.System Modules Common Control Module(CCM) 1 x 0.03000 0.03000 1 x 0.05500 0.05500 NAC 1 and 2--Class B Class B(NAC 1 + NAC 2) 1 x 0.00000 0.00000 1 x 0.06500 0.06500 NAC 3 and 4--Class B Class B(NAC 3+ NAC 4) 1 x 0.00000 0.00000 1 x 0.06500 0.06500 External Load A+A- 24VDC 0 x 0.00000 0 x 0.00000 2.NAC#1 SCW15 9 x 0.00000 0.00000 9 x 0.06600 0.59400 SCW30 2 x 0.00000 0.00000 2 x 0.09400 0.18800 SPSCW15 4 x 0.00000 0.00000 4 x 0.06600 0.26400 SPSCW30 1 x 0.00000 0.00000 1 x 0.09400 0.09400 SPSCW75 1 x 0.00000 0.00000 1 x 0.15800 0.15800 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC#1 Totals(Max 3.0 Amps): 0.00000 1.29800 3.NAC#2 SCW15 1 x 0.00000 0.00000 1 x 0.06600 0.06600 SCW30 2 x 0.00000 0.00000 2 x 0.09400 0.18800 SPSCW30 3 x 0.00000 0.00000 3 x 0.09400 0.28200 SPSCW75 2 x 0.00000 0.00000 2 x 0.15800 0.31600 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC#2 Totals(Max 3.0 Amps): 0.00000 0.85200 4.NAC#3 SPSCW15 6 x 0.00000 0.00000 6 x 0.06600 0.39600 SPSW30 4 x 0.00000 0.00000 4 x 0.09400 0.37600 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC#3 Totals(Max 3.0 Amps): 0.00000 0.77200 5.NAC#4 B200 SR-LF 5 x 0.00100 0.00500 5 x 0.09000 0.45000 SCWH177 2 x 0.00000 0.00000 2 x 0.28100 0.56200 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC#4 Totals(Max 3.0 Amps): 0.00500 1.01200 6.Compatible Devices not listed Other compatible devices _ 0 x 0.00000 _ 0 x 0.00000 Other compatible devices _ 0 x 0.00000 _ 0 x 0.00000 Other compatible devices 0 x 0.00000 0 x 0.00000 Total Standby Load: 0.030 Total Alarm Load: 2.335 ewel r' I System Power Requirements br M e•eY FireForce8 Fire Alarm Control Panel Protected Premises: Vail Cascade Main Bldg Lower Level East Date: 12/5/2016 Address: 1300 Westhaven Drive City: Vail State: CO Zip: 81657 Prepared By: Acme Fire Aarm Company Phone: 970-625-5535 Address: PO Box 883 Email: clint@acmealarm.com City: Rifle State: CO Zip: 81650 Primary Standby Load 0.03 Amps Current load on the primary power supply during non-alarm conditions. Primary Alarm Load 2.34 Amps Current load on the primary power supply during alarm conditions. Secondary Load Requirements 1.86 Amp Hours Total Secondary Load from the calculation table below. Current Draw Time (hours) I Total (AH) Seconday Standby Load Required Standby Time 24.00 0.030 A 24 hours 0.72 Secondary Alarm Load Required Alarm Time(hours) 0.25 2.335 A 0.250 hours 0.58 Total Secondary Load 1.55 Derating factor x 1.2 Secondary Load Requirements 1.86 AH Battery Selection 7 Amp Hours Select batteries from the list below. 7.0 AH BAT-1270 Battery(12 volt) Co Two fl Four(two 12VDC sets in parallel) Page 1 of 2 Battery Distribution Chart Shows amp-hour distribution of your selections. Secondary Alarm Load •Spare Battery Capacity 10% OSecondary Standby Load 0 Secondary Alarm Load Secondary Standby Load 13% Comments 1. Batteries will fit in the FACP cabinet. 2. Selected battery size meets secondary load requirements. 3. The selected batteries (7AH) are within the charger range of this power supply(7-26AH). Spare Battery Capacity 5.14 Battery Selection(AH)-Secondary Load Requirements(AH) Secondary Standby Load 0.86 Secondary Standby Load(AH)*Derating Factor Secondary Alarm Load 0.70 Secondary Alarm Load(AH)*Derating Factor Page 2 of 2