Loading...
HomeMy WebLinkAboutA17-0036_Silent Knight SK-Fire-CO_1501881180.pdf INTELLIV 40 OF�►, 'ORY 0. 4 SILENT SK- ' KNIGHT , # �e by Honeywell Advanced Multi-Criteria Fire/COp ctpc YServices SK-FIRE-CO offers world-class fire and carbon monoxide (CO) detection combined in a single addressable device to provide a practical and cost-effective solution for today's market. For more information about the SK-FIRE-CO, or to locate you nearest source, please call 800-328-0103. SK-FIRE-CO The SK-FIRE-CO is a plug-in, addressable device that "rte provides both fire and carbon monoxide (CO) detection. For �� \ fire, the detector combines four separate sensing elements in one unit (smoke, CO, light/flame, and heat) to sense multiple components of a fire. This approach enables `0 enhanced sensitivity to real fire with heightened immunity to / nuisance particulate. For CO, the detector's electrochemical sensing cell creates a separate signal for life safety CO detection. Released through the incomplete burning of various fuels, CO is a colorless, odorless and deadly gas that is virtually impossible to detect with the human senses. Because the potential exists for dangerous levels of CO to accumulate in almost any building, legislation mandating the use of CO detection in commercial spaces continues to increase across the U.S. and Canada. The SK-FIRE-CO is listed to SK-FIRE-CO installed in a the UL 2075 standard for system-connected life safety B200S Sounder Base (sold separately) carbon monoxide monitoring. • RealTest® CO testing capability The SK-FIRE-CO should be used in conjunction with the • UL 268 and UL 2075 listed B200S intelligent sounder base (sold separately), which can • Separates audible signal for fire or CO alarm generate either a Temp 3 pattern for fire or a Temp 4 when used with the B200S base pattern for CO alarm indication. With each sounder base • CO cell end-of-life warning and fault learning the address of the detector connected, the FACP can then command an individual sounder, or a group of Compatibility sounders, to activate. The command set from the panel can The SK-FIRE-CO is compatible with the be tailored to the specific event, allowing selection of tone, following IntelliKnight FACP's programmed for and group. For more information on the B2005 refer to Data System Sensor protocol: (Firmware version 13.0 Sheet P/N 351183. or higher). SK-FIRE-CO can also be used with the B210LP 6" standard • 5700 base, the B200SR sounder base or the B224RB relay base. • 5808 Features • 5820XL • 5820XL-EVS • Unique ability to detect all four major elements of a fire: - Smoke - Carbon Monoxide (CO) - Light/flame - Heat • Separate CO detection signal • Highest nuisance alarm immunity •Automatic drift compensation of smoke sensor and CO cell • Uses only one address on the SLC 1011 OF le. itimmir.„ Model SK-FIRE-CO Ir Agfa ktk Multi-Criteria CO Detector 0.,N1# Vail Fire&Emergency Services Specifications Ordering Information 08/04/17 Physical SK-FIRE-CO Multi-Criteria CO Detector (base Diameter: 6.875" (17.46 cm) installed in a not included) B200S base Height: 3.46" (8.79 cm) installed in Optional Accessories B200S base B200S Intelligent sounder base Shipping Weight: 4.6 oz B210LP 6" mounting base Color: Ivory B200SR Sounder base B224RB Relay base Operating M02-04-01 Detector test magnet Temperature Range: 32° F to 100° F (0° C to 38° C) M02-09-01 Telescoping test magnet Humidity: 15 to 90% relative humidity (non-condensing) Air Velocity: 0 to 4,000 ft/min (0 to 20 m/sec) Electrical Operating Voltage: 15 to 32 VDC Maximum Standby: 300pA at 24 VDC (no communication every 5 seconds with LED blink enabled) Maximum Alarm Current (LED on): 7.2 mA at 24 VDC CO Monitoring UL Standard Reference -Alarm Thresholds are as follows: Parts Per Million Detector Response Time 70 ± 5 ppm 60-240 min. 150 ± 5 ppm 10-50 min. 400 ± 10 ppm 4-15 min. Note: Per UL Standard 2075, the SK-FIRE-CO has been tested to the sensitivity limits defined in UL Standard 2034. This document is not intended to be used for installation purposes.We try to MADE IN AMERICA ft SILENT keep our product information up-to-date and accurate.We cannot cover all NI KNIGHT specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent Knight FORM#351181 Rev C by Honeywell 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800)328-0103, ©2013 Honeywell International Inc. Fax: (203)484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com