HomeMy WebLinkAboutB17-0253_Electrical load_1500653100.pdf From: Dave Collins Sent: Wednesday, July 19, 2017 2:39 PM To: Dave Collins Subject: RE: Unit load calc From: Nick Lunn [ ] To: Dave Collins Subject: Unit 501 Load Calc Antlers Unit 501 Load Calc Optional Residential Load Calculation Results: Multifamily Dwelling: Dwelling Units: Demand Factor: 100% Step 1: General Lighting and Recepticles: Total General Load @ 3VA: 7500 VA Step 1 Total: 7500 VA Step 2: AC System: 220.82(C)1 Total: 0 220.82(C)2 Total: 0 220.82(C)3 Total: 0 220.82(C)4 Total: 0 220.82(C)5 Total: 2400 220.82(C)6 Total: 0 Largest Load Per 220.82(C) Step 2 Total: 2400 VA Step 3: Fixed in Place Appliances: Step 3 Total: 2800VA Step 4: Dryers: Step 4 Total: 5500 kW Step 5: Cooking Appliances: Step 5 Total: 8000 kW General Load: First 10k @ 100%: 10000 Remainder over 10k @ 40%: 5520 1(2 Total General Load: 15520 Final Totals: Feeder Load: 17920 VA Feeder Amperage: 74.666666666667 Amps Neutral Load: 19750 VA Neutral Amperage: 82.291666666667 Amps Service Size: 100 Amps Conductor Size: Feeders per Table 310.15(B)7: Copper: 4 AWG Aluminum: 2 AWG Neutral per Table 310.15(B)7: Copper: 4 AWG Aluminum: 2 AWG Ground per Table 250.66: Copper: 8 AWG Aluminum: 6 AWG It is highly recommended to double check the calculations before submitting them on any professional level. This calculation was generated with the ReiWare,LLC Service Load Calculation Tool Available on the Apple App Store, Google Play and Amazon App Store. Sent from my iPhone Total Control Panel Luein To:iIcullin a antler,\aiLcomtin this sender from my allow list From:nicklunnccc aahou.cnin You received this message because the sender is on your allow list.