HomeMy WebLinkAboutB17-0258_G000_1501100400.pdfUtility Room
Hall
Sauna
'
14' 11"
Kelly Family Residence
Fire Restoration Repairs
List of Repairs:
-Replace drywall at walls & ceiling with 1hr rating
-Seal exposed framing
-Repaint utility room
-Install new washer & dryer
-Clean walls & ceilings throught existinghome
-Replace water heaters & boiler
-Replace electrical panels & wiringdamaged by fire
Kelly
Family
Residence
992 Vail Valley
Drive
Vail, CO 81657
G000
-NOTE:
Existing home was damaged by a fire in the utility room. These plans outline therepairs needed to remediate the damage caused by the fire & smoke.
07/26/2017
Utility Room
Hallway
Closet
3' 2' 3" 10"
14' 11"
2' 6"
2' 9"
2' 11"
8" Kelly Family Residence
Fire Restoration Repairs
New 1 hr assembly at walls & ceilings of Utility Room
- 5/8" w/ insulation at walls
- 2 layers of 1/2" gypboard at ceiling
- Clean & paint as needed to alleviate fire & smoke damage
Kelly
Family
Residence
992 Vail Valley
Drive
Vail, CO 81657
A001
Utility Room
Hallway
14' 11"
2' 6"
2' 9"
2' 11"
8" Kelly Family Residence
Fire Restoration Repairs
Replace (2) - 75 gal water heaters
75,100 Btu/h and associated piping, as needed
Replace boiler with 162,500 Btu, 84% AFUE and associated
valves & components, as needed
Kelly
Family
Residence
992 Vail Valley
Drive
Vail, CO 81657
P001
M001
Mechanical venting
at this location ofexterior wall
Utility Room
Closet
3' 2' 3" 10"
14' 11"
Kelly Family Residence
Fire Restoration Repairs
Electrical Scope:
- Replace panels at utility room
and garage
- Replace lights
- Replace damaged wires/cables as needed
- New fire alarm at utility room
- Connections at new mechanical equipment
- Replace lights
- Relocate 220 outlet
Replace circuit for water heaters with new
Replace circuit for new boiler
Replace existing panel with new / add cable tray & junction boxes for feeder cables
Add grounding wire to service panel
Kelly
Family
Residence
992 Vail Valley
Drive
Vail, CO 81657
E001
Existing electricalservice
panel location