Loading...
HomeMy WebLinkAboutInstallation Operation and Maintenance Manual.pdf ecosmar+ Fire INSTALLATION , OPERATION �L, MAI NTE NAN C E ANU AL LONG GAS BURNER MEDIUM GAS BURNER ROUND GAS BURNER ESF.1.B.G35 13.51bs/6.13kg ESF.1.B.G28 12.81bs/5.8kg ESF.1.B.G16 8.6Ibs/3.9kg CAUTION A WARNING A DO NOT DISCARD THIS MANUAL Improper installation, adjustment, alteration, •Important operating and maintenance service, or maintenance can cause injury or instructions included. property damage. Read the installation and •Read, understand,and follow these maintenance instructions thoroughly before instructions for safe installation and operation. installing or servicing this equipment. A DANGER A A DANGER A If you smell gas: CARBON MONOXIDE HAZARD • Shut off gas to the appliance. , • Extinguish any open flame. This appliance can produce • If odor continues, keep away from the ® 1 carbon monoxide which has appliance and immediately call your gas no odor. supplier or fire department. Using it in an enclosed space can kill you. A WARNING A Never use this appliance in Do not store or use gasoline, or other an enclosed space such as a flammable vapors and liquids, in the vicinity camper,tent, car or home. of this or any other appliance. An LP-cylinder not connected for use shall A WARNING A not be stored in the vicinity of this or any other appliance. For outdoor use only ENGLISH GAS FIRED EDUCATE ALL USERS CV` US Manuals can be found on our website or by contacting your local distributor. LISTED WHY REGISTER YOUR WARRANTY? LISTING AND CODE APPROVALS Registering your warranty achieves more than simply activating your A.Appliance Certification warranty-it provides our head office with the information that we require in order to communicate important safety and regulatory MODEL: ESF.1.B.G35, ESF.1.B.G28,ESF.1.B.G16 information to you should the need arise. LABORATORY: Underwriters Laboratories, Inc.(UL) TYPE: Decorative Gas-Fired Outdoor Fireplace This could include things like: STANDARD: Outdoor Decorative Gas Appliances • Prompt notification in the unlikely event of a potential hazard, ANSI Z21.97-2014 *CSA 2.41-2014 • Reminders about regular safety steps and maintenance procedures, • New model announcements or accessories that suit or enhance This appliance has been tested in accordance with ANSI Z21.97-2014 your purchase. and CSA 2.41-2014 for Canada and has been listed by Underwriters Laboratory(UL)for installation and operation as described in these It is important that we are able to communicate effectively with our installation and operating instructions. customers as part of our commitment to continual improvement, The installation must conform with local codes or,in the absence of consumer safety and property protection. local codes,ANSI Z223.1 *NFPA 54 National fuel gas code—Natural gas and propane installation code,CSA B149.1 —or propane storage If you purchased your product through an external distributor,retailer and handling code,CSA B149.2 or agent. EcoSmart Inc does not have these details on file and may have trouble sourcing them as systems and best practices vary from The appliance,when installed,must be electrically grounded in business to business. accordance with local codes or,in the absence of local codes,with Please register your warranty today.You can do this online at the National Electrical Code,ANSI/NFPA 70;or the Canadian Electrical www.ecosmartfire.com or by sending through your details as itemized Code,CSA C22.1,if applicable. on Page 19 via email to info@ecosmartfire.com. B.BTU Specifications EcoSmart Inc 3641 Holdrege Avenue,Suite B Orifice Size Max Input BTU LA 90016 USA Model T+1 (888)590.3335 LP NG LP NG E usa@ecosmartfire.com ESF.1.B.G35 #43 #31 55331 51706 ESF.1.B.G28 #43 #31 55331 51706 ESF.1.B.G16 #43 #31 55331 51706 Contents Markings 3 Important Safety Information 4 Clearances 5 Before You Start 6 Gas Hookup 7-8 Standard Equipment Received 9- 10 Burner Assembly- Propane 11 - 12 Burner Assembly- Natural Gas 13 - 14 Lighting and Operating 15 Troubleshooting 16 Service and Maintenance 17 Reference Materials 18- 19 n ri-Inwrinht 9nna_9ni F R'nCmart Inc All rinhtc rosaniari \/91 nR15 ENGLISH Markings 3 Listing Label Information/Location The model information regarding your specific appliance can be found on the rating plate attached to your burner via a metal chain. See the sample rating plate below for locations of specifications. OAS DECORATIVE FOR YOUR SAFETY, EcoSmart Inc Holdrege Avenue OUTDOOR GAS-FIRED c ULa us READ BEFORE LIGHTING 3641 Suite B,Los Angeles BURNER LISTED BURNER CA90016USA 42W4 This burner is for installation within approved MFG.DATE XX/XX WARNING! LIGHTING INSTRUCTIONS models ONLY and is not to be installed into If you do not follow these instructions exactly, Dk i custom designs. SERIAL fi XXXX DATE DE FAB.XX/)O( a fire or explosion may result causing property 1. aspark is being produced damage,personal injury,and/or loss of life. betweenepress spar the electrodeer N button tipantl and verreceiving probe. Model:EcoSmart Fire GB Series A.This appliance must be lit manually.When lighting,fallow 2.Ensure control panel valve is in the"OFF"position and ANSI 221.97-2014 and CSA 2.41-2014 for Canada. _ odree size Max Input BTU these instructions exactly. slowly open valve on propane tank.If using natural gas or Installation must conform with local codes or in the model ----- whole-House LP,open ball valve.If not using a control valve. absence of local codes,ANSI 2223.1'NFPA 54 LP I NG LP NG B.Before lighting,smell around the appliance area for gas. skip this procedure until step 3. ESFt.B.G35 04 '17°6 3 pat 55x31 1]06 Be sre to smell neat to the base of the appliance because National Fuel Gas Code-Natural gas and propane —_.-.._._ '__ some gas is heavier than air and will settle on the goer. 3.Depress sparker button and continua holding button while installation code,CSA 0149.1-or propane storage ESFI.13.G20 043 I-031 l 55331 l 51706 I turning control valve to the on position.Release button once and handling code CSA 6149.2 ESFI.B.G16 1 043 1 031 I 55331 51706 WHAT TO OO IF YOU SMELL GAS: flame is present. -- -----.---- - •Do not try to light any appliance. •Do not touch any electric switch.Do not use any phone in Type of Gas:Natural Gas,Propane Gas your building. WARNING •Immediately call your gas supplier from a neighbor's TO TURN OFF GAS TO APPLIANCE phone.Follow the gas suppliers instructions. Turn the ON/OFF valve to"OFF"position at appliance for •ll you cannot mach your gas supplier,call the fire department. a natural gas appliance For an LP appliance,turn the ON/ WARNING:Must Not Be Used For Cooking. Improper installation,adjustment,alteration, Service or maintenance can Cause injury or C.Use only your hand to turn the gas control knob or valve. OFF valve to"OFF"at the appliance,then with a Type l or II WARNING:For Outdoor Use Only.if stored Never use tools.If the valve will not turn by hand.don't connection,turn the valve at the LP cylinder clockwise to the Y property Refer to the owner's information try to repair it.Call a qualified service technician.Force or "OFF"Position when the appliance is not in use. indoors,detach and leave cylinder outdoors. manual provided with this appliance.For assistance attempted repair may result in a fire or explosion. O S additional information consult a qualified D.Do not use the appliance if any part has been underwater. taller,service agency or the gas supplier. Immediately calla qualified service technician to inspect the MINIMUM CLEARANCES:Top:6 Ft.[72"](1829mm) appliance and replace any part which has been underwater. Sides:2 Ft.[241(610mm)Bottom:[81(203mm) CAUTION:The gas pressure regulator provided with this appliance must be used.This regulator Is set for an outlet Minimum clearance from sides and back of unit to pressure of 10.5 inches water column. adjacent combustible construction below top of unit /� is 8"(203mm)from sides and 8"(203mm)from back. (i l WARNING Minimum horizontal clearance from sides and back EcoSmart Inc Do not store or use gasoline or other flammable of unit to adjacent vertical combustible construction 3641 Holdrege Avenue vapors and liquids in the vicinity of this or any extending above top of unit is 24"(610mm)from Suite B,Los Angeles other appliance.An LP-cylinder not connected sides and 24"(610mm)from back. CA 90016 USA for use shall not be stored in the vicinity of this or any other appliance. Important Safety Information Congratulations on your purchase of this decorative gas 1.EXPLOSION/FIRE HAZARD appliance.The appliance you have selected is designed to provide i. Do not operate in an area with oxygen tanks in use or if safe operation,reliability and efficiency. flammable vapors are present. This manual contains instructions for the safe installation and ii. Never smoke while lighting the appliance. use of your new gas appliance.Before installing and using this appliance,read the entire manual and follow the instructions and warnings carefully. 2.LOCATING THE FIRE This owner's manual should be retained for future reference. i. Keep children away from the appliance.Never leave children If you are the installer(and not the owner)please ensure that unsupervised when the fire is operating. this manual is given to the owner for them to learn about safe operation of the appliance and for future reference. ii. In case of emergency,have on hand a multi purpose dry chemical type fire extinguisher(ABC in USA). This appliance is a Decorative Gas Appliance for OUTDOOR USE iii. The customer warrants to EcoSmart Inc that after delivery of their ONLY and MUST NOT be used for cooking.Do not burn solid fuels in this appliance. Fire,and while EcoSmart Inc retains any interest in the goods or consigned goods(as the case may be),the customer shall comply This gas burner is for installation within approved models ONLY with all applicable acts,regulations and laws dealing with the and is not to be installed into custom designs. transport,unloading and storage of dangerous goods. The information contained in this owner's manual,unless noted otherwise,applies to all models and gas control systems. 3.OPERATING THE FIRE i. Do not use if damaged or malfunctioning. AWARNING A ii. For decorative purposes only.Not suitable for continuous operation.Do not use the appliance to heat or boil water or as If the information in these instructions is not followed a cooking appliance.Do not put wood,charcoal,paper or other exactly,a fire or explosion may result causing property combustible objects in the Fire. damage,personal injury,or loss of life. iii. EcoSmart Inc is not liable for any damage caused by using the incorrect type of fuel. vi. NEVER leave a fire unattended. WARNING A 4.HOT SURFACE HAZARD Improper installation,adjustment,alteration,service,or maintenance can cause injury or property damage.Read the i. Due to high surface temperatures,keep children,pets,clothing installation and maintenance instructions thoroughly before and furniture away from the unit for up to 1 hour of use,as the installing or servicing this equipment. unit is hot while in operation,contact with the appliance may cause skin burns. AWARNING A 5.USING ACCESSORIES It is imperative the burner be kept clean i. Use only authorised decorative media with your appliance. ii. To reduce the risk of fire or injury,do not modify the appliance in any way. AWARNING A iii.The Burner has not not been tested with an unvented gas log set.To reduce the risk of fire or injury,do not install an Do NOT use this appliance if any part of it has been underwater. unvented gas log set into this appliance. Immediately call a qualified service technician inspect the appliance and replace any part of the control system and any For decorative media you must: gas control which has been underwater. - Ensure the decorative media does not interfere with the burner parts. - Confirm quality and suitability to ensure the media will not Installation and service of this appliance should be explode,emit carbon monoxide or fumes when exposed to performed by qualified personnel.We recommend extreme temperature variations. °,i:+,` NFI certified,facto rofessionals,or technicians p - Fire accessories must not be smaller than /tin(12.7mm)diameter v supervised byan NFI certified professional. NF1 m p p so that the accessories cannot impede the burner parts. 'NsrIrut4 iv. Do not use fittings or spare parts,other than those available cEr:f;F:Eo from or recommended by the manufacturer of this appliance. If you have any questions regarding any of the above important safety information please contact your retailer or EcoSmart Inc. Please store these warnings in a safe place for future reference. lrl. r`nnwrinht 9(1(ld-9M F P,nRmart Inr All rinhtc racanwri V21 01:11 fi ENGLISH Clearances 5 When planning an appliance installation,it's necessary to determine the following information first: A WARNING A EcoSmart Inc disclaims any responsibility for,and the Environmental Conditions warranty will be voided by,the following actions: WARNING:Ensure that your fire is positioned away from flammable materials and other sources of ignition(combustible materials, gasoline and other flammable vapors and liquids)at all times.Pay • Installation and use of any damaged components. very close attention to positioning the fire away from items that may • Modification of the burner assembly or burner orifice. • move as a result of wind and drafts.For example trees/branches/ • Installation other than as instructed in this manual. curtains/paper and the like. Any such action may cause a fire hazard The base of the burner within the model must never come into direct contact with flammable materials. A WARNING A Locating your appliance Fire Risk Position the appliance adjacent to the gas supply line or LP gas Provide adequate clearance: supply cylinder. •Around air openings •For service access DO NOT locate the appliance where it will get excessively wet or Locate appliance away from traffic areas submerged in water. Minimum Clearances _ — - - - - Side clearances to fixed and stable furniture items that are not susceptible to movement such as lounges or patio furniture must remain a minimum of 24in(610mm)away from the flame at all times. Overhead clearances to items that are susceptible to movement I 72in MIN I I (e.g.Curtains/Trees)must remain a minimum of: I (1,829mm) I -78.7in(2000mm)away from the flame at all times. Ceiling clearances must remain a minimum of: -72in(1,829mm)to overhang from top of burner. 1r I Please note that: I I Any furniture items or fittings directly above or beside the Burner 724in MIN installation must be deemed suitable for heat tolerances by (610mm) I 7 their manufacturer e.g.electronic items including screens and entertainment equipment,wallpaper,laminates,veneers,glues and / reconstituted materials. 24in MIN / EcoSmart Inc is not liable for any injuries or damages sustained (610mm) through any installation not in compliance with this manual. / A fire extinguisher is strongly recommended. J 0 Before You Start Tools and Supplies A WARNING A Before beginning the installation,be sure that the following tools and supplies are at hand: Asphyxiation Risk • Gloves • This gas appliance is for outdoor use in a well-ventilated space. • Safety Glasses • This unit must not be installed inside an enclosed structure or • Phillips screwdriver unvented appliance • Non-corrosive leak-check solution • Adjustable Wrenches • 1 AAA battery CAUTION Sharp Edges Initial Safety Inspections Wear protective gloves and safety glasses during installation. Before assembling the appliance it is important to inspect the following and determine if it is safe to proceed: A WARNING • Carefully remove all burner components from packaging. • Check for damage.Do not use damaged components. Inspect appliance and components for damage.Damaged parts • The hose assembly must be replaced prior to the appliance being put may impair safe operation. into operation if there is evidence of excessive abrasion or wear,or if the hose is damaged.Do not use parts other than those specified by •Do NOT install damaged,incomplete,or substitute components. the manufacturer. Report damaged parts to your dealer. • The burner must be replaced prior to the appliance being put into operation if it is evident that the burner is damaged.Do not use parts other than those specified by the manufacturer. • Position the assembly in the desired location.This location must be adjacent to the gas supply line.You must have easy access to the gas valve control knob after it is installed and connected to the gas supply because the ON/OFF gas valve is used to turn the burner on and off. The location for the installation must be out of the pathways where people may trip over it or in areas where the hose may be subject to accidental damage. In addition,for LP Gas Models: • Be certain to mount or set the LP gas cylinder on a flat stable surface and restrain it to prevent it from tipping. • Make sure the tank valve is turned completely off(clockwise). • Ensure the tank valve has the proper external mating threads(tank valve marked"USE WITH TYPE 1"). • Inspect the hose shipped with the appliance for any damage.Do not use if there is evidence of damage. • Once assembled,position the hose out of pathways where people might trip over it or in areas where the hose might be subject to accidental damage. onnn_On1g.Gr..,e.,,orf In, 40 rink-Fe rocor`fori \/91l1R1F ENGLISH Gas Hookup 7 Fuel Before making gas connections,ensure the appliance being installed is A WARNING A compatible with the available gas type. Fire Risk Gas Pressure Explosion Risk Proper input pressures are required for optimum performance.Gas line • Gas build-up during line purge may ignite. sizing requirements need to be made following NFPA54. • Purge should be performed by qualified technician. • Ensure adequate ventilation. A WARNING A • Ensure there are no ignition sources such as sparks or open flames. Fire Risk 6 Explosion Risk Verify inlet pressures. • High pressure may cause overfire condition. CAUTION:A small amount of air will be in the gas supply lines.When • Low pressure may cause explosion. first lighting appliance it will take a short time for air to purge from lines. • Verify minimum pressures when other household gas Subsequent lighting of the unit will not require such purging.Never allow appliances are operating the ON/OFF valve to remain in the open position without pressing and continuing to hold Ignitor button FIRST. Install regulator upstream of valve if line pressure is greater than 1/2 PSI. A WARNING A Pressure requirements for appliance are shown in table below.Minimum pressures must be met when other household gas appliances are CHECK FOR GAS LEAKS operating. Fire Risk Explosion Risk Manifold Pressure Natural Gas Propane Asphyxiation Risk • Check all fittings and connections. • Do not use open flame. Minimum Inlet Pressure 7 in w.c 11 in w.c • After the gas line installation is complete,all connections must be tightened and checked for leaks Maximum Inlet Pressure 10.5 in w.c 14 in w.c with a commercially available leak-check solution.Be sure to rinse off all leak-check solution. The appliance and its individual shutoff valve must be disconnected Fittings and connections may have loosened during from the gas supply piping system during any pressures in excess of 1/2 psi(3.5 kPa). , shipping and handling The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi(3.5 kPa). Gas Connection Note:Have the gas supply installed in accordance with local building codes,if any.If not,follow ANSI 223.1.Installation should be done by a qualified installer approved and/or licensed as required by the locality.(In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter. Note:A listed(and Commonwealth of Massachusetts approved) 3/3 in(9.5mm).T-handle manual shut-off valve and flexible gas connector are connected to the 3/3 in(9.5mm)control valve inlet. If substituting for these components,please consult local codes for compliance. Incoming gas line should be piped to the 3/3 in(9.5mm)connection on the manual shutoff valve. 0 Gas Hookup 0 LP Gas Supply • The pressure regulator and hose assembly supplied with LP models must be used.Replacement pressure regulators and hose assemblies must be those specified in this manual. • The LP gas supply cylinder used with LP models must be constructed and marked in accordance with the specifications for LP gas cylinders of the U.S.Department of Transportation(DOT). Specifications for LP-Gas Cylinders,or the Standard for Cylinders,Spheres and Tubes for Transportation of Dangerous Goods and Commission,CAN/ CSA-B339,as applicable • Cylinders must be stored outdoors in a well ventilated area out of the reach of children.Disconnected cylinders must have threaded valve plugs tightly installed and must not be stored in a building,garage or any other enclosed area. • Storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply(natural gas line or LP gas cylinder). • The LP gas cylinder supply system must be arranged for vapor withdrawal. • The LP gas cylinder used must include a collar to protect the cylinder valve. • When an LP model is not in use,the LP gas must be turned off at the supply cylinder. • The specific size and capacity of the cylinder(s)to be used:20 lb.or hard plumbed to propane tank. IMPROPER INSTALLATION,ADJUSTMENT,ALTERATION SERVICES, OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO AND UNDERSTAND THIS MANUAL.FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER,LICENSED TECHNICIAN OR THE GAS SUPPLIER. ENGLISH 0 Standard Equipment Received Please ensure that all items have been received.The burners include the minimum equipment required to operate the burner safely. Burners -., - ;"` - / - ./ Long Gas Burner -ESF.1.B.G35 Medium Gas Burner-ESF.1.B.G28 Round Gas Burner-ESF.1.B.G16 Included items INSTALLATION, -- - //( OPERATION -f 1Ir�/,+ ANO MAINTENANCE �)w 7 MANUAL \/) do -Th 1)1) :-.*":5_,---ji A-=.-=== *01111 Operations Manual Flexible gas line(ships connected to burner) Orifice#43(LP-Ships Connected) Orifice#31 (NG) -C-------7 - ------ 411,01aW4 r ‘ _. (-7.",, 4000614•„‘ 'law .-.<----- V j II r� _______) 1 LP Hose&Regulator(10') Sparker Box Grounding Wire 36" (ships connected to burner) r 0 D liiliilllilllllllllllIIII "° - ® "''" � nom; -- ' 440 o ;\ ' I ooh I,,„; i Valve and Screws Control Knob and Key 4 x bolts/nuts for attaching linear Control Panel (to connect to the control panel) burner to Adapter Plate (does not ship with burner/ ships with surround unit) r-x- 0 Standard Equipment Received Assembling the control panel Confirm you have received all necessary parts as illustrated on page 9. 4.From the front of the control panel,secure the sparker by attaching the plastic nut. 1.Attach the valve to the back of the control panel using the provided screws.Valve must be installed as shown in drawing(with outlet on 5.Insert AAA battery,ensuring the+direction of the battery is facing top and inlet on bottom). outward when installed. 2.Remove the sparker cover and plastic nut from the sparker box. 6.Screw on the sparker box cover to hold battery in place. 3.Place the sparker behind the control panel and insert sparker box into control panel. o. © CM 0 1IS til / c zz, /411/ r f 1. 2. 3. ,,::=:.):e.:1::',.;:-'r hik re 3 mart au t E x fifiF'i r,, �, t 31°Pr1. L''l-, qrt 4. 5. I 6. fAl rl,.....4,.i..+nn-In nny c C....c......+i..,, nu a,.k*. ..............r \/01!141 G ENGLISH Burner Assembly - Propane — PROPANE n ( ) 1.Unpack burner box.Remove all items and check against the items listed on page 9 of the manual to ensure all parts needed are ready. 2.Ensure you have assembled the control panel,as outlined on page 10. I d \\ (6 7.Place arotective towel over the unit. Carefullyplace the burner P on Surround Unit near opening without inserting burner into the final —>--- \ location.Feed the flexible gas line,grounding wire and the Ignitor wire through the burner location and out the control panel opening of the Surround Unit(located on the side of the Surround Unit). For the Round Burner go to step 4. 8.Slide the black propane tank hose under the Surround Unit and out 3.Linear burners only:(this step is not required for round burners) through the control panel opening. The other end of the black propane Attach the burner to the adapter plate(found inside the Surround Unit) hose with the regulator will attach to the propane tank. using the four bolts and nuts provided..Ensure burner is attached to the flat side of the adapter plate marked"For Gas Burner Only".If experiencing issues lining up the holes of the burner and the adapter plate,please rotate the burner 180 degrees and try again. �oV 4 p - ,....----7.; • it 1 11111 - 4.The flexible gas line is already attached to the burner orifice.Confirm / the air shutter is open 1/4 in(6.4mm)on each side of air shutter and .. 1.. — ensure connection of flexible gas line is tight. y b.Ensure ignitor wire is secured to bottom of Ignitor. l „,„,,,'�1,1*1,*11�,����lo„v..'i- 0. ip is 6.Ensure grounding wire is secured to bottom of burner. - AgI 9.Using two adjustable wrenches,attach the flexible gas line to the top ____ �,�` valve fitting(outlet).Do not overtighten. it 1/4” 10.Using two adjustable wrenches,attach the propane tank hose to the (6.4) bottom valve fitting(inlet).Do not overtighten. ri--- 2 Burner Assembly - Propane :_ _. ( 111111,01MPVI fa 41111011. kilfilli -'-'---7: A MI I L'' ' ' 'CGCG( , C 111"2., ' Illirc , • WC 11.Ensure propane tank is in the OFF position. Attach propane hose and included regulator to propane tank. 15.Insert the fully assembled Control Panel into the side of the Surround Unit,feeding the cables and wires back in under the unit as needed until OFF the control panel is firmly in place. Ensure the control knob(or"key")is r in the OFF position. 16.Place the burner in the unit and remove the protective towel. ‘,...„........,\\ _,,. 17.Fill burner area with included decorative media.Ensure burner '''-:Z . ' '41r4. ilk is completely covered before igniting the burner or burner can be damaged. ♦„ gr,( Spread Lava Rock out evenly over burner area.Use all Lava Rock provided for best affect.Keep clear of spark to avoid accidental blockage. Must be spread evenly for even flame. 12.Ensure the control knob(or"key")is in the OFF position. r i1: i -Im ,�, �' ,�t -6 yr y:: •_i r 4 R?. ° r 'fir l i t.; fi i 4„y .,,t R t ' ��14,',' WARNING Do not burn without Lava Rock on burner. 13.Use a leak detecting solution to check all connections before operation. 14.Plug the Ignitor wire and grounding wire into the back side of the sparker. These wires can be plugged into either port on the back side of the sparker box. ©Copyright 2004-2015 EcoSmart Inc.All rights reserved.V210815 ENGLISH i____ - 3 Burner Assembly - Natural Gas _ NATURAL GAS 6. Insert orifice#31 in the gas inlet of the burner and tighten using two adjustable wrenches.Do not over tighten. Note:Connection of this product to Natural Gas must be completed by a licensed gas plumber/installer only.Do not attempt to install this product with Natural Gas without a licensed installer present. o 1.Unpack burner box.Remove all items and check against the items , listed on page 9 of the manual to ensure all parts needed are ready. 2.Ensure you have assembled the control panel,as outlined on page 10. 0-- `iliac i►i' _ I r U { 1 )`.` "`m #31 �J \ t._ 7.Re-attach the flexible gas flex line to the orifice.Do not over tighten. r 8.Adjust air shutter to between 1/16 in(1.6mm)open to completely �'—t closed,on each side of air shutter. For the Round Burner go to step 4. h• o 3.Linear burners only:(this step is not required for round burners). ---- -- '1,'W; Attach the burner to the adapter plate(found inside the Surround Unit) using the four bolts and nuts provided. Ensure burner is attached to the flat side of the adapter plate marked"For Gas Burner Only".If ;€--, -� n,.,:,w, experiencing issues lining up the holes of the burner and the adapter plate,please rotate the burner 180 degrees and try again. 1/16" Q p p (1.5) p _ 9.Ensure ignitor wire is secured to bottom of Ignitor. r Q _ e 10.Ensure grounding wire is secured to bottom of burner. 11. Place a protective towel over the Surround Unit.Carefully place the burner on Surround Unit near opening without inserting burner into the final location.Feed the flexible gas line,grounding wire and ,.," ____/___,--1,---,_ the Ignitor wire through the burner location and out the control panel � � opening located on the side of the Surround Unit. 12.Using two adjustable wrenches,attach the flexible gas line to the top valve fitting(outlet).Do not overtighten. 4.Using two adjustable wrenches,remove the flex line from the burner orifice. -...., g5.Using two adjustable wrenches,remove the#43 orifice from the gas 444110 lefirairre inlet of the burner. ;� } al Ile Burner Assembly - Natural Gas — 13.Route the natural gas line from below the Surround Unit out through 17.Plug the Ignitor wire and grounding wire into the back side of the the control panel opening. sparker. These wires can be plugged into either port on the back side of the sparker box. 0 LUrr(18_, 10 Ik 41r .01 14.Using two adjustable wrenches,attach the natural gas line to the bottom valve fitting(inlet).Do not overtighten. It is strongly 18. Insert the fully assembled Control Panel into the side of the recommended to place a manual shutoff valve in the natural gas line Surround Unit,feeding the cables and wires back in under the unit as before it reaches the valve on the control panel. needed until the control panel is firmly in place. 19.Place the burner in the unit and remove the protective towel. 20.Fill burner area with included decorative media. Ensure burner --_ is completely covered before igniting the burner or burner can be damaged. �-,. ;� � (111/Wit'.rr Spread Lava Rock out evenly over burner area.Use all Lava Rock Itittdc,..,,,,,ip_cr,qm � provided for best affect.Keep clear of spark to avoid accidental III �'� blockage. Must be spread evenly for even flame. 1°1r.- 4' / \ i. Fra a 15. Ensure the control knob(or"key")is in the OFF position. Ha t' .K+�s+`4 f ',',:-.i it, 't, ;' r ., „ i. ams ( .`( �V�i��`t, b WWARNING A Yi a ti Do not burn without Lava Rock on burner. l 5 16.Use a leak detecting solution to check all connections before operation. ©Coovriaht 2004-2015 EcoSmart Inc.All riahts reserved.V210815 ENGLISH Lighting and Operating FOR YOUR SAFETY, READ BEFORE LIGHTING To Extinguish Turn control valve to"OFF"position or close ball valve.Close valve on WARNING! If you do not follow these instructions propane tank while not in use. exactly,a fire or explosion may result causing property Initial break-in procedure:When you light the appliance,you may damage, personal injury,and/or loss of life. notice that it produces heat which may have an odor.If you feel this odor is excessive it may require an initial three to four hour continuous A.This appliance can be lit electronically or with a match.When lighting, burn on high. follow these instructions exactly. B.Before lighting,smell all around the appliance area for gas.Be sure A WARNING A to smell next to the base of the appliance because some gas is heavier than air and will settle on the floor. FIRE RISK—HIGH TEMPERATURES WHAT TO DO IF YOU SMELL GAS: Keep combustible household items away from appliance. • Do not try to light any appliance. • Do not touch any electric switch,do not use any phone nearby. • Do NOT obstruct combustion and ventilation air. • Immediately call your gas supplier from a neighbors phone.Follow gas • Do NOT place combustible items on top of or near appliance. supplier's instructions. • Keep furniture,draperies away from appliance. • If you cannot reach your gas supplier,call the fire department. • Do NOT use,lantern fuel,kerosene,charcoal lighter fluid,bioethanol or similar liquids in this appliance. C.Use only your hand to turn the gas control knob on propane tank(if • Combustible materials,flammable liquids,or vapors may ignite. equipped),never use tools.If the valve won't turn by hand,don't try to repair it,call a qualified service technician.Force or attempted repair may result in a fire or explosion. D.Do not use the appliance if any part has been underwater. Immediately call a qualified service technician to inspect the appliance and replace any part which has been underwater. E.The gas pressure regulator provided with this appliance must be used. This regulator is set for an outlet pressure of 10.5in(267mm)water column. Lighting Instructions 1.Depress sparker button and verify a spark is being produced between the electrode tip and receiving probe. 2.Ensure control panel valve is in the"OFF"position and slowly open valve on propane tank.If using natural gas or whole-house LP,open ball valve.If not using a control valve,skip this procedure until step 3. 3.Depress sparker button and continue holding button while turning knob to the"ON"position.Release button once flame is present. WARNING:If the flame does not ignite within 5-10 seconds turn the gas"OFF"and wait for 5 minutes before re-attempting to ignite. Failure to follow this instruction may result in a volatile ignition due to the build up of vapors. • • kcilk ,r, Troubleshooting — 0 Symptom Possible Causes Corrective Actions A. No LP in tank,or NG main not turned on. Check the LP(propane)tank.You may be out of gas.Or check Natural Gas valve at main. 1. Appliance won't light Plugged burner orifice. Check the burner orifice for stoppage.Remove stoppage. C. No spark igniting burner Refer to ignitor on section 7 below. Low flames or Manual shutoff valve(on/off control knob) Close LP tank and manual shutoff valves.Open LP 2, A. open or not in-stalled between LP tank and tank valve first,THEN the manual shutoff valve. won't stay lit appliance. This is a result of normal operation and A. flames will begin to yellow as unit is allowed No action required. to burn for 16-20 minutes. 3. Blue Flames Improper air/fuel mixture related to air Close air shutter.(for LP,leave 1/4 in[6.4mm]open, B. shutter position. Natural gas 1/16in[1.6mm]open). Noise is caused by metal expanding and contracting as it heats up and cools down, 4. Metallic noise A. , similar to the sound produced by a furnace No action required. ' or heating duct.This noise does not affect the operation or longevity of the appliance. Lava rock cracking orThis is a property of lava rock and may happen 5. splitting A. Heat and/or abrupt temperature changes. occasionally.Do nothing.This is completely normal. A. Ignitor is improperly grounded. Check all wire connections at back of sparker box. Ensure ignitor wire and grounding wire are securely Ignitor makes clicking B. ' Ignition or ground wire not plugged in. attached to burner. 6. sound but no visible spark is produced Check that tip of ignitor is within 1/4 in(6.4mm) C. Ignitor tip set too far from grounding probe. of grounding probe.Gently bend Ignitor tip or grounding probe by hand to achieve a smaller gap. A Battery low,Not installed,Installed Ensure that a fresh AAA battery is installed Positive incorrectly. (+)side facing outward toward the sparker cap. Check contact at the bottom of the battery cavity B. Corrosion on battery contacts. for corrosion.Clean with a small piece of sandpaper Ignitor does not spark or or a file. 7' make a ticking sound If the cap cannot be screwed down tight enough, the battery will not make a proper connection with C. Battery cap not screwed down completely. the sparker and it will not work.Be sure to use a thin surface such as 20-22 gauge sheet metal to mount sparker in. n nonvrinht 2004-2015 EcoSmart Inc.All rights reserved.V210815 ENGLISH Service and maintenance 1 7 Although the frequency of appliance servicing and maintenance will depend on use and the type of installation,a qualified service technician A WARNING A should perform an appliance check-up annually. Storage of an appliance indoors is permissible only if the cylinder is Annual inspection by qualified technician recommended. disconnected and removed from the appliance. Check: •Obstructions of combustion and ventilation air. Stainless steel will rust or corrode over time if contamination or •Condition of burner assembly debris is not cleaned or removed immediately.When not in use,it is recommended that you protect your fireplace from water damage or •Burner ignition and operation corrosion with a protective cover. •Burner air shutter adjustment •Gas connections and fittings A WARNING A Risk of: •Fire Risk of injury or property damage. •Delayed ignition or explosion �' Before servicing: •Exposure to combustion fumes •Turn off utilities to appliance o/ •Odors •Ensure appliance is completely cooled Maintenance and Service Tasks Like all fire and fireplace systems,it's important to run through regular safety checks.Please take the time to familiarise yourself (and any other users)with the safety procedures associated with using your firepit. Inspect • Maintenance Tasks 1 Remove decorative lava rock and examine burner.Vacuum and wipe out as needed. Use caution when cleaning these areas 2 Inspect for warping and corrosion. Repair as necessary Burner Assembly 3 Check the hose connecting the LP gas cylinder to ensure it is not damaged.Replace as necessary. 4 Verify air shutter area is clean 1 Verify all gas connections are tight and leak-free 2 Clean burner top,inspect for plugged ports,corrosion,or deterioration.Replace burner if necessary. 3 Inspect for flame problems. Burner Ignition and Operation 4 Verify air shutter is clear of dust and debris and is in correct position for the gas type being used. 5 Inspect orifice for soot,dirt,or corrosion 6 Verify manifold and inlet pressures.Adjust regulator as required. Gas Hose with Regulator 1 The gas hose with regulator supplied with appliance must be used for LP installations. The replacement must be those specified by the appliance manufacturer 0 0 0 Reference Materials — Service Parts List Replacement Parts SKU LP/NG BURNER Burner Assembly EcoSmart Fire Long Gas Burner ESF.1.SU.G35 Burner Assembly EcoSmart Fire Medium Gas Burner ESF.1.SU.G28 Burner Assembly EcoSmart Fire Round Gas Burner ESF.1.SU.G16 Control Key ESF.1.P.KEY Control Knob ESF.1.P.KNB Fastener Kit for Adapter Plate ESF.1.P.FST Flex Line(36") ESF.1.P.F36 Gas Control Panel-Flat ESF.1.P.CPF Gas Control Panel-Urth ESF.1.P.CPU Grounding Wire 36" ESF.1.P.G36 Igniter ESF.1.P.IGN LP Hose&Regulator(10') ESF.1.P.H10 Orifice#31 ESF.1.P.031 Orifice#43 ESF.1.P.043 Sparker Box ESF.1.P.GSB Valve Components ESF.1.P.VAL MODELS Linear Burner Adapter Plate(G35) ESF.1.P.A35 n nnnvrinht 9004-2015 EcoSmart Inc.All rights reserved.V210815 ENGLISH O Reference Materials Limited One Year Warranty EcoSmart Inc extends the following warranty for GB Series decorative This warranty is limited to the replacement or repair of defective outdoor gas fire products used in the United States of America or components or workmanship and EcoSmart Inc may fully discharge its Canada.Dealers and employees of EcoSmart Inc have no authority obligations under this warranty by repairing or replacing,at its discretion, to make any warranty or authorize any remedies in addition to or the defective components.EcoSmart Inc will provide replacement parts inconsistent with the terms of this warranty.This warranty gives you at no charge and will pay reasonable freight costs related to replacing • specific legal rights.You may also have other rights that vary from state or repairing defective components under this warranty.The maximum to state. amount recoverable under this warranty is limited to the purchase price of the Product and,if EcoSmart Inc is unable to provide replacement EcoSmart Inc warrants that this GB Series decorative gas appliance(the or repair in an expedient and cost-effective manner,EcoSmart Inc may "product")will be free from defects in material and workmanship for a discharge all obligations under this warranty by refunding the purchase period of one year from its date of purchase.Stainless steel parts and price of the Product. assemblies carry a limited lifetime warranty.This warranty is subject to the conditions,exclusions and limitations described below. EXCEPT TO THE EXTENT PROVIDED BY LAW,ECOSMART INC MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY This warranty applies only to the original owner of the Product and is EXPRESSED HEREIN.THE DURATION OF ANY IMPLIED WARRANTY non-transferable.EcoSmart Inc obligation under this warranty does IS LIMITED TO THE DURATION OF THE WARRANTY SPECIFIED not extend to damages resulting from(1)assembly,operation or ABOVE.IN NO EVENT SHALL ECOSMART INC BE LIABLE FOR ANY maintenance of the Product not in accordance with the Installation/ INCIDENTAL OR CONSEQUENTIAL DAMAGES CAUSED BY DEFECTS Assembly Instructions,Operating Instructions and the Listing Agency IN THE PRODUCT.Some states do not allow limitations on how long an Identification Label furnished with the Product;(2)installation or use implied warranty lasts,or do not allow exclusion or limitation of incidental which does not comply with local building codes and ordinances; or consequential damages,so these limitations may not apply to you. (3)shipping,improper handling,improper operation,abuse,misuse, accident or unworkmanlike repairs;(4)use of fuels other than those To obtain service under this warranty,you must: specified in the Operating Instructions;(5)Installation or use of 1.Send written notice of the claimed condition to: components not supplied with the Product or any other components not 3641 Holdrege Avenue,Suite B, Los Angeles CA 90016 USA expressly authorized and approved in writing by EcoSmart Inc;and/or (6)modification of the Product not expressly authorized and approved 2.Affirm that you are the original owner of the Product. in writing by EcoSmart Inc.Any of the circumstances described in 3.Photos or video of issue will be required in order to asses the warranty the previous sentence voids this warranty.This warranty is void if the claim. Product or any component has been removed,repaired,or replaced before EcoSmart Inc has been afforded a reasonable opportunity to 4.Provide EcoSmart Inc reasonable opportunity to investigate the claim, inspect the Product. including reasonable opportunity to inspect the Product prior to any repair or replacement work and before the Product or any component of the Product has been removed. 20 The Warranties set out above are express Warranties given by DATE OF PURCHASE EcoSmart Inc and are in addition to the rights and remedies which are conferred upon consumers by Trade Practices Act 1974 of the PURCHASED FROM Commonwealth and other Commonwealth,State or Territory legislation. PRIMARY USE Service under the warranties set out above must be provided by EcoSmart Inc Authorised Customer Service Centre which shall MODEL NAME provide service during their normal working hours. SERIAL NUMBER This warranty certificate along with proof of date of purchase must You will find this on the dataplate on the side of the burner be produced when making any claim. FIRST NAME For warranty claims please contact your local distributor.If there is not LAST NAME a local distributor in your country please visit www.ecosmartfire.com to source the details of the country closest to you. EMAIL *Do not return this form to EcoSmart Inc,please retain for your own ADDRESS reference. CITY STATE ZIP COUNTRY • omit_om 0-nRrnart Inc All rinhts reserved.V210815 EcoSmart Inc 3641 Holdrege Avenue Suite B Los Angeles CA 90016 USA T+1 (888)590.3335 E customersupport@ecosmartfire.com V210815