Loading...
HomeMy WebLinkAboutDRB16-0225_A0.0_1478908130.pdf Z + rn BASS HAUS REMODEL ,,,, DRB APPROVED 6/14/2016 12:00:00 AM 312 MILL CREEK CIRCLE ri i -• _. . — 1, ;lb .. . . . ;.,.., .i...!.r,, - •-•• • .,...., . . ..-,i,:..t../.... "1 /; TURNIPSEED * 1 111 _7 .:-e yL.F • _ rik .�r ', _ 1 ,i• _ 5 -- _M ARCHITECTURE 31F ' ,*` {�•. • t �'r . C O N S T R U C T I O N R ij wi - INTERIOR DESIGN `ry' • ...4.L .7, - . - . . Lili '-i, 11,..._-:- -4` SINCE 1 9 9 S / • . - ; ''' j-- .'-'1Th' • -. .. . L ]j.' -'P - • Ci4:ro. . ,.. , . „ . 'Ir..' 'i.• 44 V54;4. - :. . 1 • . . 1: I. •• A." '' . 4: . ; elif . .-i_. • tot _% .11. . .- .4 .:.. . -_:_iuJ: ,? - 44., iel. 1 .‘ I, 4: • =.r . . +. • *' i ,ti1 ' . ' 7 h + f _ ii' • -.. .. I - _ ,_ . , 1 . n r r } . - , _. ,' .. til. . it 1 ! • ' 4 , i7 ~ 11U x ■ r 5 O W ., It 4.,:e.t. • , 'P % 1 Ili- ' LLI _1 < _ • _ r, .....,0-4_,L " - `�` -°' Ifs , LLI • . -r'y -.F+'., .P y m` { rI .m1-1 7117 J 1 _ {' 4 _ c.':. CC —1 0 • ice-.- •• - _ � , , ' " ' ' - . = — - _ 316 • = J = — U N O PERMIT SET Cr) M MARCH 11 , 2016 Q CO i- 0 J OWNERS: DRAWING INDEX: PROJECT VAIL BASSHAUS LTD, ETAL A0.0 COVER SHEET REVISED 4.12.16, 6.8.16 SUMMARY: �P °F 400 COLO s. PO BOX 439 A1.1 SITE PLAN WINNSBORO, TEXAS 75494-0439 1 OF 1 TOPOGRAPHIC MAP/SURVEY PARCEL NUMBER: 2101-082-49-002 fA ' 411,4* BARBARA MORONEY REMODEL : SINGLE FAMILY * 1R ci IPS * PHONE (214)351-6559 ARCHITECTURAL PLANS: NUMBER OF STORIES : 4 4l 4338 moroney7@gmail.com AS BUILT, DEMO, AND REMODEL INTERIOR PARKING: 2 r ti A2.1 LOWER LEVEL FLOOR PLAN REVISED 6.8.16 BATHROOMS: 7 '��NSED ARO N\��/ ARCHITECT : A2.2 MAIN LEVEL FLOOR PLAN REVISED 6.8.16 A2.3 BALCONY LEVEL FLOOR PLAN GENERAL NOTES: SCOTT S. TURNIPSEED AIA A2.4 ATTIC LEVEL FLOOR PLAN ISSUE: DATE: ARCHITECTURE & CONSTRUCTION, INC. DEMOLITION -AS NOTED ON PLANS. 1143 CAPITOL STREET, SUITE 211 A4.1 DECK SECTIONS & RAILING DETAILS NEW 6.8.16 AS BUILT DRAWINGS 11.17.2015 P.O. BOX 3388 ASBESTOS ABATEMENT REQUIRED PRICING PLAN 11.22.2015 EAGLE, COLORADO 81631 ORIGINAL DRAWINGS: SEE REPORT BY DS ENVIRONMENTAL CONSULTING PHONE (970) 328-3900 x4 PROJECT NUMBER13662, DATED 12.14. 2015. ENGINEER SET 1.27.2015 alicia@sstaia.com A-1 PLOT PLAN REMODEL REVIEW SET 2.5.2016 A-2 LOWER FLOOR PLAN SEE ALSO LEAD BASED PAINT INSPECTION PERMIT SET 3.11.2016 A-3 MAIN FLOOR PLAN AND XRF TESTING REPORT STRUCTURAL A-4 BALCONY FLOOR PLAN PROJECT NUMBER 13662, DATED 12.14.2016 ELECTRICALAS-BUILTS 5.16.2016 ENGINEER: A-5 NORTH & EAST ELEVATIONS DECK REVISIONS 6.8.2016 A-6 SOUTH &WEST ELEVATIONS PROJECT TO COMPLY WITH TOWN OF VAIL REQUIREMENTS, ANDERSON STRUCTURAL THE 2015 INTERNATIONAL RESIDENTIAL CODE, ENGINEERING STRUCTURALS: AND THE 2015 INTERNATIONAL ENERGY CONSERVATION CODE LANDON ANDERSON, PE WHERE APPLICABLE. 488 ELK RUN ROAD S1.0 GENERAL STR NOTES REVISED 4.12.16 NEW CASTLE, CO 81647 S1.1 MAIN LEVEL FRAMING PLAN REVISED 4.12.16, 6.8.16 ALL DIMENSIONS ARE APPROXIMATE, BASED ON AS-BUILT PHONE (970) 984-0320 S1.2 BALCONY LEVEL FRAMING PLAN DRAWINGS PROVIDED BY OWNER. landon@anderson-structural.com S1.3 ATTIC LEVEL FRAMING PLAN S5.1 SECTIONS & DETAILS REVISED 4.12.16, 6.8.16 EXISTING FLOOR AREA: SURVEYOR: ELECTRICIAN: LOWER LEVEL = 1,821 SF ARCHIBEQUE LAND CONSULTING, LTD. COBALT ELECTRIC CORPORATION MAIN LEVEL = 2,194 SF 115 BROADWAY NICK LUNN BALCONY LEVEL = 1,147 SF PO BOX 3893 PO BOX 71 ATTIC LEVEL = 368 SF EAGLE, CO 81631 GYPSUM, CO 81637 PHONE (970) 328-6020 PHONE (970) 309-7054 TOTAL FINISHED = 5,530 SF SCOTT S. TURNIPSEED AIA info@prolandsurvey.com cobaltelectriccorp@gmail.com ARCHITECTURE GARAGE = 548 SF & CONSTRUCTION INC. CONTRACTOR: ELECTRICAL LOAD CALC: MECHANICAL/UNFIN = 188 SF PO BOX 3388 1143 CAPITOL STREET, SUITE 211 PER COBALT ELECTRIC CORP. EAGLE,COLORADO 81631 NEDBO CONSTRUCTION INC. TOTAL = 6,266 SF 970.328.3900 WWW.SSTAIA.COM PO BOX 3419 CURRENT SERVICE IS 200 AMP EXISTING FLOOR AREA UNCHANGED 159a phase ampacity, 96a neutral ampacity VAIL, CO 81658 PHONE (970) 845-1001 PROPOSED LOAD: EXISTING HEATING/COOLING: CELL (970) 977-0268 152a phase ampacity, 89a neutral ampacity rollie@nedbo.com CURRENT SERVICE OF 200 AMP IS ADQUATE FOR HOT WATER BASEBOARD, NATURAL GAS REVISED ELECTRICAL PROPOSED AIR CONDITIONING: NONE