Loading...
HomeMy WebLinkAboutAC Specs.pdf MITSUBISHI ELECTRIC .SI UM,: C O OLING & HEATING Split-ductless A/C and Heat Pumps .x- SUBMITTAL DATA: SEZ-KDG9 Z9NA. _ , - -9,000 auitORIZONTAL DU t RUMR SYSTEMS Job Name: 45 Forest Rd. Location:$% Foret Rd Date:7-1-16 Purchaser:R&H Mechanical Engineer:Chris Jacobs Submitted to: For ❑Reference ❑Approval DConstruction System Designation:AV Room A/C Schedule No.: i - 1 itt t M i lila 1 tit 0 GENERAL FEATURES �a ")1!! l 'llll ''t av •Horizontal-ducted indoor unit for concealed --i t ' li Oji '1 (� i •Ultra thin body:7-7/8"high q 1' •Built-in drain mechanism for condensate removal;lifts to 21-11/16" Indoor Unit:SEZ-KDO9NA lq: 1i1 ll i s i i il; •Air filter is included with indoor unit tR i 6 fl I I •Quiet operation—as low as 23 dBA t�; iii,i ii 'II i, •Indoor unit powered from outdoor unit using A-Control it l I Ni •Automatic fan speed control •Auto restart following a power outage - - •Limited warranty:five years on parts/defects;seven years on compressors Outdoor Unit:SUZ-KAO9NA OPTIONAL ACCESSORIES Indoor Unit Voltage o Filter Box with MERV 8 Filters(FBL1-1) Indoor-Outdoor S1-S2 AC 208/230V o Bottom Return Plate(BRP-1) Indoor-Outdoor S2-S3 ..... -...`..... DC 12-24V Outdoor Unit Indoor Unit o Drain Socket(MAC-860DS) MCA 1 A o Drain Pan Heater(MAC-640BH-U) Fan Type x Quantity Sirocco Fan x 2 o Three-pole Disconnect Switch(TAZ-MS303) Fan Motor Type Direct-driven DC Brushless Motor o Air Outlet Guide(MAC-856SG) Fan Motor Output 96 W o Mounting Base(DSD-400N) Fan Motor 0 51 F.L.A. o Mounting Pad(ULTRILITE1) Airflow(Lo-Med-Hi).................194-247-317 Dry_CFM o Wall-mounting Brackets(CWMB1) 174,-222 2$ - FM ,,� Air Filter ............`............--.-Polypropylene,'; ®n- comb External Static Pressure 0 02-0.06-0.14-0.20"WG Controller Options Sound Pressure Level(Lo-Med-Hi) 23-26-30 dB(A) o Wall-mounted Wired Remote Controller(PAR-21 MAA) o M-NET Control Adapter(MAC-399lF) DIMENSIONS UNIT INCHES/MM o Remote Temperature Sensor(M21-JKO-307) W 31-1/8/790 o Hand-held Wireless Remote Controller D 27-9/16/700 (PAR-FL32MA;req.PAR-FA32MA-E) ❑ Wireless Signal Receiver Module PAR-FA32MA H 7-7/8/200 (for PAR-FL32MA-E) Weight 42 lbs./19 k o Lockdown Bracket for Hand-held Controller(RCMKPICB) External Finish Galvanized-steel Sheets Field Drainpipe Size 0.D.......................1-1/4"/32 mm Cooling* Outdoor Unit Compressor DC Inverter-driven Rated Capacity 8,100 Btu/h MCA 12 A Capacity Range 3,800-10,900 Btu/h MOCP 15 A SEER 15.0 Fan Motor............... ................0.50 F.L.A. Total Input 670 W Sound Pressure Level ; Heating at 47°F+ Cooling .................. ...................46 dB(A) Rated Capacity 10,900 Btu/h - i • . . . " +e • Capacity Range 4,800-14,100 Btu/h HSPF 10.0 Total Input 1 020 W DIMENSIONS INCHES/MM Heating at 17°F* W 31-1/2/800 Rated Capacity 6,700 Btu/h D 11-1/4/285 Rated Total Input 810 W H 21-5/8/550 Maximum Capacity 6,700 Btu/h Weight 66 lbs./30 kg Maximum Total Input 1 000 W External Finish Munsell No.3Y 7.8/1.1 'Rating CondAions(Coo4ng)-Indoor.80°F(Z7°C)DB,67°F(19°C)W8;Outdoor.95°F(35°C)DB,75°F(24°C)WB. (Heating at 47°F)-Indoor.70°F(21°C)D6,60°F(16°C)Wa,Outdoor:47°F(8°C)DB,43°F(6°C)WB. Refrigerant Type R410A (Healing at 17°F)-Indoor.70'F(21°C)D8,60°F(16°C)ws;Outdoor.17'F(-8°C)08,15°F(-9°C)W3. Refrigerant Pipe Size O.D. Electrical Requirements Gas Side 3/8"/9.52 mm Power Supply 208/230V,1-Phase,60 Hz Liquid Side 1/4"/6.35 mm Recommended Fuse/Breaker Size 15 A Max.Refrigerant Pipe Length 65'/19 m -< Max.Refrigerant Pipe Height Difference 40'/12 m OPERATING CONDITIONS Connection Method Flared e Indoor Intake Air Temp. Outdoor Intake Air Temp. Maximum 90°F(32°C)DB,73°F(23°C)W8 115°F(46°C)DBMIN Cooling Minimum 67°F(19°C)DB,57°F(14°C)W8 14°F(-10°C)DB ,.,; I N`f ER R ir Maximum 60°F(27°C)DB 67°F(19°C)WB 75°F(24°C)D8,65°F(18°C)We Heating ,. Minimum 70°F(21°C)DB,60°F(16°C)W8 -4'F(-20°C)DB,-5°F(-21°C)W8 51 2011 MITSUBISHI ELECTRIC&ELECTRONICS,INC. .:---SEZ•ii-KDO9NA-INDOORFAN--PERFORMAI4CE-AND CORRECTED AIR-FLOW CHARTS SEZ-KDO9NA SEZ-KDO9NA (External static pressure 0.02[in.WG1(5Pa)) 208/230V 60Hz (External static pressure 0.06[in.WG](15Pa)) 208/230V 60Hz 40 50 [0.16) [ [0.20) Limit Limit a a 40 a 30 ).".--)[0.16] 3 [0.12) 3 N _. a 30 ♦ High ♦ 2 [0.12] \♦ 20 a �♦ 5 [0.08] `♦ ♦ A y \ m ♦ m 20 m ,♦High `m [0.08] s •Middle ♦♦ it ♦ ` 10 �` ♦♦ w -�� Rated point•♦♦ - - [0.0 •4] Middle ♦ 10 Low •♦ ♦ • ` Low ti ♦, ♦♦ 0 s`\ N. Rated( point,` Ns,, •`, ♦v 4 5 6 7 8 9 10 4 5 6 7 8 9 - 3fl � [141] [176] [212] [247] [282] [318] [353] [141] [176] [212] [247] [282] [318]- j3533 Airflow rate(m'/min)[CFMJ Airflow rate(m'/min)[CFM] SEZ-KDO9NA SEZ-KDO9NA (External static pressure 0.14[in.WG](35Pa)) 208/230V 60Hz (External static pressure 0.20[in.WG1(50Pa)) 208/230V 60Hz 80 80 [0.32] _. ] [0.321 _. Limit Limit 70 70 d [0.28] a [0 .28] ♦♦ High 3 [0.24] 3 [p24) ,�♦♦♦ •L 50 •♦. m 50 Rated point• 5 [0.20] ♦ y [0.20) %• 6. High d ?♦ i40 ,. 0 40 [0. 16] ♦ 'f [0.16] `� Middle ♦ a Rated point♦ _ `� c 304 E 30 [0.12] �� Middle ♦♦ [0.12[ �, .. w N N. w a, Low '• [0.08] `. `` [0.08] `\ ` • Low ` • �, `N10 �., 10 [0.04] `N �Ns [0.04] .N, Ns �` 0 .tea ` 0 4 5 6 7 8 9 10 4 5 6 7 8 9 10 [141] [176] [212] [247] [282] [318] [353] [141) [176] [212] [247] [282] [318] [3531 Airflow rate(m'/min)[CFM] Airflow rate(m'/min)[CFMJ '.. ©2011 MITSUBISHI ELECTRIC&ELECTRONICS,INC. 15-3/4 Drain hole ¢1-5/8 Unit: inch c? Air in 7— N Air in m i 6- N ,1-9/16 O'Air out 2-3/8 x 13/16 Oval hole 7/8 1 29/3211-1/4 _.17/32 handle IIIII1111111111111111111111111111111111111 -�I IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII co IIIIIIIIIIIIIIIIillllllllllIlllllillll IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII N M IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII �, Liquid pipe :1/4(flared) IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 111.1 Gas pipe :3/8(flared)(KA09/12) r„ 1/2(flared)(KA15) _ — — M' 11-29132 6-23/32 5-15116 19-11/16 31-1/2 2-23/32 REQUIRED SPACE Basically open 4 inch or more without any obstruction in front 11,611.0.0 and on both sides of the unit. Q`�,o 4,hor� oro, ' —44 `��� mote Pi •4�n'or�ore Open two sides of left, right,or rear side. •-i-tL*111:S .-_ • MITSUBISHI ELECTRIC COOLING & HEATING CERTIFIED- ENERGY STAR - ++ werdicam€r��a� " Live Better uat,ItyPARTNER lEHP _ US 3400 Lawrenceville Suwanee Rd ,:. " "' .._ GUS Suwanee,GA 30024 Tele:678-376-2900•Fax:800-889-9904 Intertek Toll Free:800-433-4822(#3) www.mehvac.com FORM#SEZ-KDO9NA&SUZ-KAO9NA-201108 Specifications are subject to change without notice. 5 2011 MITSUBISHI ELECTRIC&ELECTRONICS,INC. Unit : mm(in.) 345(13-19/32) Drain pipe(O.D.o32(1-1/4)) (Emergency draining) ) • '.37(1-15/32) a-, : 7053-15/16) } y I 1 Suspension bolt hole 20(13/16) ,//157.5(6-7/32) 't 1519/32) :4.,__ -----..-.-, ^� /4.14X30(9/16X1-3/16)Slot 12(1/2)_ J 37(1-15/32) :■ I 2XE-o2.9 1/8) .g. ( L-02.9 1/8 tt yTTyy "'(((" i I l/_ 1 II r I • IT .*. LL I U A Y t' I�$, .4:-'. m . f--i&W a X i--r_-_- _-ic. Air Air z g �:' o a outlet N inlet a * :-.-. O! M 0 p♦ o I. J_ a (rte �° .�►.�. • .■ Qi �,I _7 _ iti T N r `Air filter c5 r' c 11■13/32 _ N 49 3O a cu r N m 625 Suspension bolt.itch mm m N N(1-15/16 (24-5/8) S m _g, Drain pipe(O.D.o32(1-1/4)) Knockout hole 027(1-3/32) N (Indoor/outdoor connecting line) M 700(27-9/16) mm Knockout hole x27( 1-3/32)7wm 23(29/32) ( 6- ) yNo (Remote controller transmission sion line)10(13/32) , Control boxo ` NN w nl -r II__. ,-; 1 K - S.' 116 70 Terminal block(Indoor/outdoor connecting line) (4-19/32) (2-25/2) 2X2-02 9(1/8) 270(/0-z1 32 Terminal block(Remote controller transmission line) 1)Refri.erant.i.in. ))Refd.erant.i.in. Drain pipe(O.D.o32(1-1/4)) flare connection(gas) flare connection(liquid) (Spontaneous draining) Less than 300 (11.13/16) - O ��1' 175±5 8-29/3gth( ri„, ,: t.-,s1.„ "�11al g/l ' 311 g192\ (Actual length) .o� �� - -��- y.� *! .� so-` Access door 1� T •'� i N m N Ceiling surface Access door So(r.3'•� 4,-, !1� 7iYu�ynnl=II . L Note2 G 7/32 '.*** m w yr �``� + 1k J o Make the access door at the appointed position properly �7.37/a so �► A�°,�2\�,60,61 for service maintenance. ISO Q'S.. 7,2332)\{�oe�r1s� Drainhose t.D.e32 1-1/4 Required space for service and maintenance mm(in.) Model A B C DE F G H J K L M N1Q Gas pipe ()Liquid pipe SEZ-KDO9NA (27-1116) 0 700 (24-35/ (37981 660(61 7 .6.05?,2 ) 18001 (60 5 '1g00fi 16 (8396)(31-10- SEZ-KD12NA 09.52(3/8) 900 952 998 860 800 1000 860 700 1039 990 SEZ-KD15NA (35.7(16) (37-j/2) (39'5/76) (33.7/8) 9 (311,2) (39-are) Garel 7 Iv-sn6) 20 +,ao-s�32 (3s) 06.35(1/5) 1100 1152 1198 1060 1000 1200 1060 900 1239 1190 e12.7(1/z) SEZ-KD18NA (43-5/76) (45-347/ (47.3/16) (41-3,4) 11 (39-3�5) (47-1/41 (41-34) 9 (35-7/16) 24 '45.20722 (5/73) Notel.Use M10 screw for the suspension bolt(field supply). 2.Keep the service space for the maintenance at the bottom. 3.This chart indicates for SEZ-KD15NA model,which has 3 fans. SEZ-KD09,12NA models have 2 fans. SEZ-KD18NA models have 4 fans. 4.In case an inlet duct is used,remove the air filter(suppty with the unit),then install the filter(fietd supply)at suction side. ©2011 MITSUBISHI ELECTRIC&ELECTRONICS,INC.