HomeMy WebLinkAboutDRB16-0337_M-0_1478898742.pdf X10(1 °F 1"4/ A111114e; I;., ,) _, ] "I] _'' '''_ e C.IL: _ _ a i 0 H -- 4. MECHANICAL GENERAL NOTES SYMBOL LEGEND SYMBOL LEGEND ABBREVIATIONS Building Efficiency and Sustains 3 Aria% 1 . ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITIONS OF THE RULES, REGULATIONS -CI MATCHING LINE ® FD FLOOR DRAIN ABV ABOVE INV INVERT ELEVATION AND CODES OF THE STATE OF COLORADO AND THE LOCAL JURISDICTIONAL AUTHORITY. ACU AIR CONDITIONING UNIT KW KILOWATT A L:aVOC�C �jkc cuhtu Eny 18x12 2. THIS CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL WORK UNDER HIS/HER CONTRACT WITH ALL © SECTION DESIGNATION . SECTION NUMBER DUCT SIZE (CLEAR INSIDE DIMENSION) AD ACCESS DOOR KWH KILOWATT HOUR OTHER BUILDING TRADES. ® DRAWING NUMBER I FIRST FIGURE INDICATES PLAN SIZE AFF ABOVE FINISHED FLOOR LAT LEAVING AIR TEMP. 4. 18x12 } 3. ALL EQUIPMENT & DUCTWORK TO BE HELD HIGH AS POSSIBLE NEAR STRUCTURE UNLESS NOTED OTHERWISE. ik I AL ACOUSTICAL LINING LBS POUNDS DETAIL DESIGNATION DETAIL NUMBER 181) 4, ALTITUDE LD LINEAR DIFFUSER 4. THIS CONTRACTOR SHALL REVIEW EXISTING FIELD CONDITIONS PRIOR TO THE PURCHASE, FABRICATION AND ® DRAWING NUMBER S r S INSTALLATION OF ANY EQUIPMENT, DUCTWORK, PIPING, ETC., AND SHALL INFORM THE ARCHITECT OR GENERAL APPROX APPROXIMATE LPR LOW PRESSURE STEAM CONTRACTOR OF ANY DISCREPANCIES FOR RESOLUTION. ® EQUIPMENT EQUIPMENT TYPE I, 184) 3 ROUND DUCT DIAMETER SIZE RETURN DESIGNATION EQUIPMENT NUMBER ARCH ARCHITECTURAL 5. CONTRACTOR SHALL PROVIDE OWNER WITH COPIES OF OPERATIONS AND MAINTENANCE MANUALS FOR ALL ,�TYPE (SEE SCHED) NEW WORK AVG AVERAGE LPS LOW PRESSURE STEAM ‘AO INSTALLED WGS-1, 12x12 WGS-1, 12x12--SIZE 18x12 SUPPLY AIR OUTLET/INLET �_ - BF BELOW FLOOR 6. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND DO NOT SHOW EVERY DUCTWORK OFFSET REQUIRED. (550) DEVICE DESIGNATION (550)x CFM rACOUSTIC LINING IN DUCT BG BELOW GRADE LVR LOUVER THIS CONTRACTOR SHALL COORDINATE WITH THE EXISTING, AND OR NEW, STRUCTURE, ELECTRICAL, 1 18x12 (SIZE NOTED INDICATES INSIDE DIMENSIONS) MAZZETTI 4MECHANICAL, PLUMBING, FIRE PROTECTION AND CEILING TO PROVIDE OFFSETS AS REQUIRED AND - - - BHP BRAKE HORSEPOWER LWT LEAVING WATER TEMP. APPROPRIATE. 0 PROJECT NORTH ARROW MAT MIXED AIR TEMPERATURE 1600 Stout Street, Suite 450 18x12 BO BLANK OFF r Denver, CO 80202 7. ALL RECTANGULAR AND ROUND DUCTWORK SHALL BE CONSTRUCTED OF GALVANIZED SHEET METAL IN S S DOUBLE WALL DUCT BOD BOTTOM OF DUCT MAX MAXIMUM TEL: 720.644.5044 ACCORDANCE WITH SMACNA HVAC DUCT STANDARDS. DUCTS TO BE SEALED PER SMACNA PRESSURE CLASS 0 S ELBOW TURNED UP 18x12 (SIZE NOTED INDICATES INSIDE DIMENSIONS) BOP BOTTOM OF PIPE MBD MANUAL BALANCING www.mazzetti.com REQUIREMENTS. C—S ELBOW TURNED DOWN BTU BRITISH THERMAL UNIT DAMPER Project Number: 164-041 8. ALL NEW RECTANGULAR DUCTWORK SHALL HAVE DUCT LINER IN COMPLIANCE WITH NFPA 90A AND AS S C S BOTTOM PIPE CONNECTION S 11111111 MBH THOUSAND BTU HOUR DEFINED IN KEYNOTES. SHEET METAL SIZE SHALL BE INCREASED TO ACCOMMODATE THICKNESS OF LINER. BTUH BTU PER HOUR BTU/ HOUR SIZE INDICATED ON DRAWINGS IS THE INSIDE CLEAR DIMENSION. I TOP PIPE CONNECTION II0- FLEXIBLE CONNECTION IN DUCT CC COOLING COIL MFG MANUFACTURER S C C S SLOPED CHANGED IN PIPE ELEVATION MIN MINIMUM 9. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE SPATIAL REQUIREMENTS, ACOUSTICAL, THERMAL, AND CD CEILING DIFFUSER ELECTRICAL PERFORMANCE CHARACTERISTICS AND COORDINATION OF ALL INSTALLATION REQUIREMENTS FOR S S PITCH PIPE DOWN IN DIRECTION OF FLOW WAWA/ FLEXIBLE DUCT CE CEILING EXHAUST (N) NEW EQUIPMENT SUBSTITUTIONS FROM THAT DEFINED AS THE BASIS FOR DESIGN. REVIEW AND APPROVAL BY THE DESIGN TEAM DOES NOT ALTER OR MITIGATE THIS RESPONSIBILITY. S-© S PUMP $ r S CFF CAP FOR FUTURE N/A NOT APPLICABLE S iiiiiiiiiil 5 PIPING FLEXIBLE CONNECTION 10. CONTRACTOR SHALL VISIT THE PROJECT SITE TO BECOME ACQUAINTED WITH EXISTING CONDITIONS. FAILURE L VOLUME DAMPER IN DUCT CFH CUBIC FEET PER HOUR NC NORMALLY CLOSED TO DO SO SHALL NOT RELIEVE CONTRACTOR FROM THE RESPONSIBILITY FOR PERFORMING THE WORK S D4 i GATE VALVE T CFM CUBIC FEET PER MINUTE NIC NOT IN CONTRACT PROPERLY. S aQ S GLOBE VALVE S--N 11 . MAINTAIN ALL REQUIRED SERVICE AND ACCESS CLEARANCES REQUIRED BY CODE OR THE MANUFACTURER FOR — �—S CHECK VALVE RECTANGULAR CG CEILING GRILLE NK NECK MAINTENANCE FOR ALL EQUIPMENT, INCLUDING THE 36" ELECTRICAL CLEARANCE WHERE REQUIRED BY NEC. S S AUTOMATIC 2-WAY CONTROL VALVE, PNEUMATIC SUPPLY DUCT UP CO CLEAN OUT (DOOR) NO NORMALLY OPEN OR 4:::::11 COND CONDENSATE NUMBER 12. NEW WORK IS SHOWN AS BOLD. S A S AUTOMATIC 2-WAY CONTROL VALVE, ELECTRIC CONN CONNECTION, CONNECT NTS NOT TO SCALE 13. REFER TO BASE BUILDING DRAWINGS AND SPECIFICATIONS FOR INFORMATION CONCERNING EQUIPMENT, RELIEF VALVE CONT CONTINUATION OA OUTSIDE AIR DUCTWORK, PIPING, ETC., SHOWN BUT NOT SPECIFIED OR INSTALLED UNDER THIS CONTRACT. S—[ RECTANGULAR \ SUPPLY DUCT DOWN COP COEFF. OF _OBD OPPOSED BLADE DAMPER / 14. THE MECHANICAL CONTRACTOR SHALL CLOSELY COORDINATE WITH GENERAL CONTRACTOR TO ADJUST SPACING S [A S PRESSURE REDUCING VALVE (PRV) IL X PERFORMANCE OD OUTSIDE DIMENSION OF FLOOR, WALL AND ROOF JOISTS WHERE POSSIBLE TO OBTAIN SUFFICIENT ROOM TO RUN DUCTWORK. WHERE CONFLICTS EXIST, CONTACT ARCHITECT AND ENGINEER FOR RESOLUTION PRIOR TO FABRICATION. S--1\5'1--e LUBRICATED PLUG VALVE ORD OVERFLOW ROOF DRAIN COTG CLEAN OUT TO GRADE 15. DUCTS STORED ON THE CONSTRUCTION SITE SHALL BE PROTECTED AND ISOLATED FROM DUCT S S CALIBRATED FLOW CONTROL VALVE IA RECTANGULAR CP CONDENSATE PUMP A P PRESSURE DROP OR CONTAMINATION. S—Cl S BALL VALVE RETURN DUCT UP DIFFERENTIAL 5-11-1 BUTTERFLY VALVE -1=1A CR CEILING REGISTER P PUMP S 4 j MANUAL AIR VENT DROP PC PUMPED CONDENSATE S 4A j AUTOMATIC AIR VENT D OR INDIRECT DRAIN PH PHASE (ELECTRICAL) RECTANGULAR DB DRY BULB PHC PREHEAT COIL I THERMOMETER WELL RETURN DUCT DOWN - 4 THERMOMETER + / POC POINT OF CONNECTION MECHANICAL SHEET INDEX DDC DIRECT DIGITAL PRESS PRESSURE PRESSURE GAUGE AND GAUGE COCK CONTROL SHEET NUMBER DESCRIPTION S S 0 RECTANGULARDEG. F DEGREES FAHRENHEIT PSI POUNDS/SQUARE INCH M-0 MECHANICAL LEGEND & GENERAL NOTES S Q S FLOW MEASURING STATION 1=0 EXHAUST DUCT UP DIA DIAMETER PSIG POUNDS GAGE SQUARE INCFINNED TUBE HEATING ELEMENT M-1 MECHANICAL SITE AND ROOF PLAN DN DOWN R RISE S I S TEMPERATURE-PRESSURE TEST FITTING DRG DRAIN RA RETURN AIR RECTANGULAR DWG DRAWING RAD RETURN AIR DUCT S—CD —.4-S CONDENSATE DRAINEXHAUST DUCT DOWN (E) EXISTING REVISIONS v RD ROOF DRAIN NO. DATE DESCRIPTION S ► S ARROW INDICATES DIRECTION OF FLOW / EA EXHAUST AIR RF RETURN FAN S— D S DRAIN LINE EAD EXHAUST AIR DUCT - 08/12/2016 REVIEW SET V VENT LINE OR DAMPER RH RELATIVE HUMIDITY S—C> S CONCENTRIC REDUCER ROUND DUCT, UP RPM REVOLUTIONS/MINUTE EAT ENTERING AIR TEMP. S—ED S ECCENTRIC REDUCER EDB ENTERING DRY BULB RPBFP BPRESS. BACKFLOW PREV. S 'I' UNION S—�, TEMP. S SANITARY SEWER S 1>T1S STOP CHECK VALVE 1,-',-) ROUND DUCT, DOWN EF EXHAUST FAN SA SUPPLY AIR S D4 I CAPPED PIPE WITH SHUT-OFF VALVE EFF EFFICIENCY SAD SUPPLY AIR DUCT S—I DIRT POCKET + :] + DUCT ACCESS DOOR ET EXPANSION TANK SEC SECOND EWB ENTERING WET BULB _ SF SUPPLY FAN S I I ; "Y" TYPE STRAINER WITH EWT ENTERING WATER TEMP. HOSE END BLOW OFF VALVE S� SP STATIC PRESSURE J, EXH EXHAUST SPEC SPECIFICATION MITERED ELBOW EXP EXPANSION SQ SQUARE DEGREES FAHRENHEIT SS STAINLESS STEEL FLA FULL LOAD AMPS STD STANDARD S—j. FLR FLOOR SYM SYMBOL ELBOW WITH TURNING VANES FPM FEET PER MINUTE SYS SYSTEM FPS FEET PER SECOND A T TEMPERATURE DIFF. ARCHITECTS PROJECT# FS FLOOR SINK E S S FT FEET TEMP TEMPERATURE CLIENT PROJECT# N. 18x12 J, TOP TOP OF PIPE DUCT SPLIT WITH SPLIT SIZE FV FACE VELOCITY - GA GAGE OR GAUGE TT TEMP. TRANSMITTER CLIENT ACCOUNT# N 18x12 GPM GALLONS PER MINUTE TYP TYPICAL N cn S GPH GALLONS PER HOUR U.C. UNDERCUT PROJECT TITLE GSM GALVANIZED SHEET METAL V VENT, SANITARY 1 + + BRANCH TAKEOFF WITH VOLUME DAMPER VTR VENT THRU ROOF SIMBA RUN HC HEATING COIL `E HD HEAD VAIL CONDOMINIUMS ? El CEILING SUPPLY DIFFUSER HGT HEIGHT - DUCTWORK RE MODEL m HOA HAND, OFF, AUTO 0 CEILING RETURN REGISTER OR GRILLE HP HORSE POWER SHEET TITLE 7 I71 CEILING EXHAUST REGISTER OR GRILLE HR HOUR(S) HVAC HEATING, VENTILATING MECHANICAL DIFFUSER, REGISTER OR GRILLE THROW INDICATOR T , AND AIR CONDITIONING (SUPPLY, RETURN OR EXHAUST) LEGEND & GENERAL NOTES ID INSIDE DIMENSION 0 IN INCHES SCALE DATE D E N/A 7-19-2016 0 SHEET NO. , V N O L M .0 C N