Loading...
HomeMy WebLinkAboutDRB16-0352_A4.2_1478908267.pdf so.lti OF go .4":14, ck:iige Ili 4X8 PRESSURE TREATED TIMBER Z 4. s n SAILOR COURSE BORDER : gji PLAZA SERIES PAVERS (2:3 PROPORTION) Oj ,051. 1017 DRB NEW POLYMER MODIFIED GEMENT NEW POLYMER MODIFIED GEMENT $2s 20 ED WATERPROOFING DECK SURFACE EXISTING SLIDING WATERPROOFING DECK SURFACE 12:00:0'AM GLASS DOOR OR SYSTEM CONSISTING OF METAL LATH, SYSTEM CONSISTING OF METAL LATH, ENTRY DOOR A81 POLYMER MODIFIED CONCRETE, A8I POLYMER MODIFIED CONCRETE, lektial ._.,K BARRIER GUARD, RESISTITE, AND TWO BARRIER GUARD, RESISTITE, AND TWO GOATS OF POLYESTER URETHANE GOATS OF POLYESTER URETHANE SEALANT ALL SUPPLIED BY NEW FIBERGLASS GRATE _ • SEALANT ALL SUPPLIED BY CONTRACTOR (SLIP COEFFICIENT TO _ CONTRACTOR (SLIP COEFFICIENT TO BE 0.8 WET OR DRY) SLOPE 1/8" PER SLOPE_ 1 BE 0.5 WET OR DRY) SLOPE I/8" PER VI CT 0 R MARK FOOT AWAY FROM BUILDING D 0 N A L D S 0 N FOOT AWAY FROM BUILDING RE: - , NEW,6" WIDE BY 1 7/8" DEEP PROJECT MANUAL j1 / J -�-- -- ALUM. GUTTER CONTRACTOR TO ' _...4----_ _...4---- TAPERED FOAM INSULATION TAPERED FOAM INSULATION / / FIELD VERIFY LENGTH PRIOR NEW CO FLASHING , � NEW 5/8" EXTERIOR GRADE PLYWOOD NEW 5/8" EXTERIOR GRADE TO ORDERING GUTTER 1 \ \ PLYWOOD CONT. NEW PAINTED I •.`�\\\\a�\\� \\ \ ---"Ii. -----7------ TREX TRANSCEND "TREE HOUSE" TREX TRANSCENDS "TREE HOUSE" GALVANIZED FLASHING 1 DECKING (TO BE GUT TO SIZE AT DECKING (TO BE GUT TO SIZE AT X0000000\`+\0 1 L EDGES WHERE DECKING ADJOINS EDGES WHERE DECKING ADJOINS BUILDING BUILDING T30 CONSTRUCTION SCREWS EXISTING OR NEW �� CONT. NEW PAINTED GALVANIZED © CONT. NEW PAINTED GALVANIZED - FLASHING " PLYWOOD I FLASHING ON ALL FRAMING I/2 ► EXISTING OR NEW LEDGER, A4.2-Iv ' TIMBERS (NEW 4 EXISTING) 1 �, A. _,`\`\ \`\`\`\`\`\`\ i RE: STRUCTURAL PLANS 1 ARCHITECTURE NEW,6X14 WOOD BEAM, SEE I PLANNING STRUCTURAL PLANS 1 -• EXISTING STUCCO INTERIORS 1 SINCE 1977 % NEW kxb WOOD POST, SEE / ARCHITECT S STRUCTURAL PLANS N 90IA BENCHVARKROAD SUITE 207 FARTAL CPAVER 0SCALE: I" = I' - o" T 'P GAL DEC/< SITTER SCALE: 3" _ I' - o" BOX 5300 AVON CO 81620 ETALI 970 . 949 . 5200 0 vmda@vmda. com SCALE: 3" = I' - o" FAX 949 , 5205 EXISTING STUCCO .46 NEW "J" WEEP SCREED (STllGGO ....v...---=:.BorroM EDGE) C�04>y NEW POLYMER MODIFIED GEMENT 1\ SYSTEM CONSISTING OF SURFACE C2 VI''TGR 0 MI POLYMER MODIFIED CONCRETE, 2" GLEAN * COMPACTED71r �H!�RK \ / 5/8" WIRSBO SNOW-MELT SYSTEM ON BEDDING JOINT SAND " .0) BARRIER GUARD, RESISTITE, AND re / ` #IOx#10 -b"xb" E. H.M. t'" TWO GOATS OF POLYESTER 4 X 8 P.T. TINKER +�. URETHANE SEALANT ALL SUPPLIED I I/2" RIGID EXISTING LANDSCAPING '``� `V BY CONTRACTOR (SLIP COEFFICIENT INSULATION S•C--� AP�� TO BE 0.5 WET OR DRY) SLOPE I/8" �/'moi r I �� �II�I � �``'~- -" 1� PER FOOT AWAY FROM BUILDING % A �4 \ / , TAPERED FOAM INSULATION / / NEW DONT. GAL. 4 IIIIIIIIIIIII IIIIIIIIIIII�IIIIIIIIIIIIII � Riesling�IIIIIIIIIIIlIIIIIIIIII�III�,,, _ ,d IILIIIIIII M I FLASHING I //- - NEW 5/8" EXTERIOR GRADE PLYWOOD rl�•��i t ��•���� 1 ,�,••06011�•, a ei�.e�OW�LI ,6 OF ROAD BASE MATERIAL .,000.0,•�• I N\ TREX TRANSCEND TREE HOUSE •��S ��io •w : uii t ' z. •Vi •ti Z 1 DECKING (TO BE CUT TO SIZE AT / K \ \\ \\ \\ \ / / 0C/) 1 ". BUI�DNGHERE DECKING ADJOINS \ \\ \ \ MASONRY PAVERS,2 3/4" 1-111Z. \ J iim 1 / /PAVESTONE " PLAZA SERIES" � W CONT. NEW PAINTED GALVANIZED \/\/PAVESTONE "HOLLAND SERIES \ / Oa EXISTING OR NEW I 1/2" PLYWOOD 1 \ FLASHING \ A A A /PERIMETER ROW. \ /\\ /\\ /\ ' E I EXISTING OR NEW LEDGER, TF I RE: STRUCTURAL PLANS I GAL PAVESDETA I L = m = m 0 C5} SCALE: I" = I' - O" v = `.` D Q .0 EXISTING STUCCO ILL Z L.LI 0 Q vO w aCC0 Wow CO � � ZQ " Q045 Et O (2). ETAL W v Q SCALE: 3" = II - O" 0 ....J Z 4CC, CiaO H ©COPYRIGHT Victor Mark Donaldson Architects All Rights Reserved REVISION DATE 08.16.2016 JOB NO. 1605 DETAILS SHEET NO. A4 . 2