HomeMy WebLinkAboutDRB16-0370_A0.00 BDR_1478901164.pdf *IA OF grA
,,,,9",..
4*:0
a
01 F
fa IV
354 BEAVER DAM ROAD RESIDENCES 40 I.41
�O
DRB
APPROVED
9/21/2016
12:00:00 AM
VAI L5 COLORADO ID
N g
MATERIAL SYMBOLS: ABBREVIATIONS: GENERAL NOTES: DRAWING INDEX: GENERAL AND SITE
ff. A0.00 COVER
EARTH PLYWOOD ABV ABOVE L LENGTH U
0
01 DO NOT SCALE DRAWINGS TOPOGRAPHIC SURVEY
AFF ABOVE FINISHED FLOOR LDT LIGHT AND DRAPERY TROUGH
u
AP ACCESS PANEL LT LIGHT TROUGH E
. o -o�-o� POROUS FILL/DRAINAGE �r= / FINISH WOOD AC ACOUSTICAL LTL LINTEL 02 VERIFY ALL DIMENSIONS, CONDITIONS AND UTILITY LOCATIONS ON L1 EXISTING SITE PLAN n
THE JOB SITE PRIOR TO BEGINNING ANY WORK OR ORDERING H
14.414.414.414.414.41414.414.414.14.414.414.414.4 ADD ADDENDUM LVR LOUVER L2 PROPOSED SITE PLAN Ca
ADJ ADJACENT MH MANHOLE ANY MATERIALS. nOTIFY ARCHITECT OF ANY CONFLICTS OR
ALT ALTERNATE MFR MANUFACTURE (ER) DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY. L3 LANDSCAPE CALCULATIONS
ii ,/
��� ��
ALUM ALUMINUM MO MASONRY OPENING 03 AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY E
//////////z/ STONE STONE MASONRY WOOD-ROUGH
ARCH ARCHITECT (URAL) MTL METAL L4 LANDSCAPE SIGHT DISTANCE RESOLVED WITH WRITTEN APPROVAL FROM THE ARCHITECT BEFORE
BSMT BASEMENT MAX MAXIMUM zi H =
BRG BEARING MECH MECHANIC (AL) CONSTRUCTION CONTINUES IN THOSE AREAS. L5 LANDSCAPE PLANTING PLAN u
BVL BEVELED MC MEDICINE CABINET W o
STRUCTURAL CONCRETE BLOCKING 04 PLAN DIMENSIONS ARE TO FACE OF STUD OR FACE OF CONCRETE,
BIT BITUMINUOUS MEM MEMBRANE UNLESS OTHERWISE NOTED.SECTION AND ELEVATION DIMENSIONS ARE L6 LANDSCAPE MATERIALS/LIGHTING0 L
BLK BLOCK M METER (5) TO TOP OF CONCRETE,TOP OF PLYWOOD, OR TOP OF WALL PLATES OR L7 LANDSCAPE PLANTING DETAILS -
BLKG BLOCKING MM MILLIMETER (S) BEAMS UNLESS OTHERWISE NOTED.
CONCRETE MASONRY UNIT L GYPSUM BOARD BOT BOTTOM MIN MINIMUM .,v 0 N Q
BLDG BUILDING MIR MIRROR 05 PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. w N
CPT CARPET (ED) MISC MISCELLANEOUS LOCATIONS INCLUDE BUT ARE NOT LIMITED TO CEILING AND WALL DRAWING INDEX: ARCHITECTURAL le - v,
CSMT CASEMENT MULL MULLION MOUNTED FIXTURES,TOILETS,TOILET ACCESSORIES, CABINETRY,
/mu BATT INSULATION C CAULK (ING) NAT NATURAL COUNTERTOPS,SHELVES AND CLOSET RODS.
CLG CEILING NR NOISE REDUCTION A2.00 GRFA/SITE COVERAGE CALCULATIONS
CT CERAMIC TILE NOM NOMINAL
06 O DENOTES DOORS. REFER TO FLOOR PLANS FOR LOCATIONS. REFER
• CLR CLEAR NIC NOT IN CONTRACT TO DOOR SCHEDULE FOR DOOR TYPES. AZ.O1 LOWER LEVEL PLAN
RIGID INSULATION COL COLUMN NTS NOT TO SCALE
CONC CONCRETE OPG OPENING 07 O DENOTES WINDOWS. REFER TO WINDOWS AND FLOOR PLANS FOR AZ.OZ MAIN LEVEL PLAN
CMU CONCRETE MASONRY UNIT OPP OPPOSITE LOCATIONS. REFER TO WINDOW SCHEDULE FOR WINDOW TYPES. A2.03 MAIN LEVEL PLANUll
CONST CONSTRUCTION OPH OPPOSITE HAND
1/ // I STEEL/METAL AS NOTED CONT CONTINUOUS OH OVERHEAD A2.04 UPPER LEVEL PLAN
CJT CONTROL JOINT PR PAIR 08 COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT
CPR COPPER PK PARKING la WITHIN CEILING, FLOOR AND WALLS SPACES. VERIFY LOCATIONS WITH A2.05 ROOF PLAN
CUST CUSTOM PVMT PAVEMENT ARCHITECT. A3.01 BUILDING ELEVATION
IIIIIIIIIIIIIIIII llT CARPET DT DRAPERY TROUGH PL PLASTIC LAMINATE
IIIIMu DTL DETAIL PT POINT
DIM DIMENSION PSF POUNDS PER SQUARE FOOT A3.02 BUILDING ELEVATION
09 IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY
a
DR DOOR PSI POUNDS PER SQUARE INCH THE CONTRACTOR FOR CONSTRUCTION OF ANY ASPECTS OF THIS
DRW DRAWING PL PROPERTY LINE PROJECT,THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE A3.03 BUILDING ELEVATION
DF DRINKING FOUNTAIN QT QUARRY TILE ARCHITECT.
ELEC ELECTRIC (AL)
REF REFERENCE A3.04 BUILDING ELEVATION
EL ELEVATION (S) REF REFRIGERATOR 10 THE CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL A3.05 BUILDING ELEVATION
I ELEV ELEVATOR REIN REINFORCE (D), (ING)
A4.00
4 00 EQ EQUAL REQ REQUIRED APPLICABLE CODES AND OBTAINING ALL PERMITS AND REQUIRED
EXH EXHAUST RES RESILIENT APPROVALS. THIS PROJECT IS GOVERNED BY THE INTERNATIONAL A3.06 BUILDING ELEVATION
BUILDING SECTION REFERENCE ELEVATION REFERENCE EXTG EXISTING REV REVISION (D), (ING) BUILDING CODE, 2003 MANDATORY.THE CONSDTRUON.CTIONODE DOCOMPLIANCE IS UMEN S SHALL NOT PERMIT A3.07 BUILDING ELEVATION
la
EXT EXTERIOR REV REVERSE
FOC FACE OF CONCRETE RH RIGHT HAND WORK THAT DOES NOT CONFORM TO ALL RELEVANT CODES A3.08 BUILDING ELEVATION
FOF FACE OF FINISH R RISER INCLUDING IBC AND ALL LOCAL AND REGIONAL CODES.
FOM FACE OF MASONRY R&S ROD AND SHELF A4.01 BUILDING SECTION
FOS FACE OF STUDS RD ROOF DRAIN 11 THE CONTRACTOR SHALL FIELD COORDINATE AND OBTAIN A4.02 BUILDING SECTION
FIN FINISH (ED) RDT RECESSED DRAPERY TRACK APPROVAL FROM THE ARCHITECT & ENGINEER BEFORE ANY
1 ( 1 FFE FINISHED FLOOR ELEVATION RFG ROOFING
CUTTING, NOTCHING OR DRILLING OF ANY CAST-IN-PLACE
A4.00 `� A4.00 FE FIRE EXTINGUISHER RM ROOM CONCRETE,STEEL FRAMING, OR ANY OTHER STRUCTURAL ELEMENTS A4.03 BUILDING SECTION
FDC FIRE DEPARTMENT CONNECTION RO ROUGH OPENING WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE BUILDING. A4.04 BUILDING SECTION
FHC FIRE HOSE CONNECTION R/S ROUGH SAWNfin
DETAIL REFERENCE DETAIL REFERENCE FEC FIRE EXTINGUISHER CABINET S SEALANT (EXTERIOR) A4.05 BUILDING SECTION
FP FIREPLACE SHTG SHEATHING
FPS FIREPROOFING, SPRAYED SHH SHOWER HEAD 12 THE CONTRACTOR SHALL VERIFY ALL EXISTING GRADES AND STAKE A4.06 BUILDING SECTION 0
MAIN 1 FLG FLASHING SHC SHOWER CONTROLS OUT THE BUILDING FOOTPRINT FOR OWNER AND ARCHITECT M la Q
AL 100'0" A FLR FLOOR (ING) SM SHEET METAL APPROVAL PRIOR TO BEGINNING ANY SITE WORK. A4.07 BUILDING SECTION
FD FLOOR DRAIN SIM SIMILAR 0 a
FTG FOOTING SC SOLID CORE 13 IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE A4.08 BUILDING SECTION z 1= 5
HEIGHT REFERENCE FND FOUNDATION SPEC SPECIFICATON (S) CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, 0
SECTION REFERENCE A4.09 BUILDING SECTION FBO FURNISHED BY OTHERS SQ SQUARE MATERIALS,TRANSPORTATION, SUPPLIES, EQUIPMENT, ETC.TO OBTAIN O
FPHB FREEZE PROOF HOSE BIB STD STANDARD A COMPLETE JOB WITHIN THE RECOGNIZED STANDARDS OF THE A5.01 WIN DOW DETAILS
' �^�1 FUR FURRED (ING) ST STAIN INDUSTRY. W 0
GA GAGE, GAUGE STL STEEL A6.01 EXTERIOR DETAILS 0
ROOM NAME GALV GALVANIZED SD STORM DRAIN J
GC GENERAL CONTRACT (OR) STR STRUCTURAL 14 ALL BUILDINGS TO FIT WITHIN PROPERTY LINES WITHOUT CROSSING Q
ra GL GLASS, GLAZING TEL TELEPHONE EASEMENTS OR SETBACKS. NOTIFY ARCHITECT OF ANY DISCREPANCIES. A6.02 EXTERIOR DETAILS A a
1 GYP GYPSUM BOARD TV TELEVISION A6.03 EXTERIOR DETAILS
REVISION REFERENCE ROOM NAME HB HOSE BIB THR THRESHOLD 15 PROVIDE ACCESS PANEL TO MOTOR FOR ALL WHIRLPOOL-TYPE TUBS. 1.1
HDW HARDWARE T&G TONGUE AND GROOVE COORDINATE ACCESS LOCATIONS WITH INTERIOR DESIGNER AND A6.04 EXTERIOR DETAILS J
HDR HEADER TOS TOP OF SLAB ARCHITECT TO PROVIDE INCONSPICUOUS LOCATION. a4E
O
HTG HEATING TOS TOP OF STEEL
HVAC HEATING/VENTILATING/AC TOW TOP OF WALL
GRID W11 HT HEIGHT TB TOWEL BAR DRAWING INDEX: LIGHTING N2
HC HOLLOW CORE TR TRANSOM
HM HOLLOW METAL T TREAD E2.01 LOWER LEVEL PLAN k Cl
GRID BUBBLE WALL TYPE REFERENCE HOR HORIZONTAL TYP TYPICAL
HWH HOT WATER HEATER UNO UNLESS NOTED OTHERWISE E2.02 MAIN LEVEL PLAN 0 cc
INCL INCLUDE (D), (ING) VB VAPOR BARRIER ml la
1 ID INSIDE DIAMETER VIF VERIFY IN FIELD p R E T D E M MARY. E2.03 MAIN LEVEL PLAN m
IBC INSTALLED BY CONTRACTOR VERT VERTICAL
OJECT C O S U
A8. 2 IBO INSTALLED BY OWNER VCT VINYL COMPOSITION E2.04 UPPER LEVEL PLAN o) W
4 I INS INSULATE (D), (ION) WC WATER CLOSET Code:
INT INTERIOR WP WATER PROOFING International Residential Code 2015 ~ m
3 JC JANITOR'S CLOSET WWF WELDED WIRE FABRIC Occupancy: One-Family Dwelling
ml la 3
KIT KITCHEN W WIDTH, WIDE M
INTERIOR ELEVATION REFERENCE WINDOW TAG LAM LAMINATE (D) WDW WINDOW Separations:
LAV LAVATORY WO WITHOUT
1 Hour (residence/garage)
LH LEFT HAND WD WOOD 1 Hour (residence/mechanical)
Special Attributes:
® STN--.--/-.-TILE Addressable Fire Alarm System
Automatic Sprinkler System
DOOR TAG MATERIAL BREAK
ICE
la
41
1111)
0111)
ISSUED FOR: DATE.
SCHEMATIC DESIGN 3.3.16
PEC APPEAL 5.23.16
CONCEPTUAL REVIEW 6.18.16
COPY RIGHT RESERVATION T.O.V.DRB FINAL REVIEW 8.29.16
The drawings,specifications and other documents
prepared by the Architect (Michael Suman Architect,
LLC) for this project are instruments of the Architect's
service for use solely with respect to this Project and,
unless otherwise provided in writing, the Architect shall be
deemed the sole and exclusive author of these
documents and shall retain,without limitation, all
common law, statutory and other reversed rights,
including the copyright hereof. No person,whether
having come rightly into possession hereof or otherwise, 2016 MICHAEL SUMAN ARCHITECT,LLC.
shall employ these documents on any other project, nor C ALL RIGHTS RESERVED.
for additions to this Project nor for the completion of this SCALE: 1/4"=1,-0"
Project by others, unless with the prior express written
consent of the Architect and upon appropriate DRAWN: MDS
compensation to the Architect in an amount and kind
satisfactory to the Architect. The Architect expressly PROJECT#: 1506
claims all proprietary rights in the material which is issued SHEET TITLE: COVER SHEET
in confidence for design and/or construction purposes of
this Project as noted. These materials may not be
copied, modified, nor employed in any way without the
specific prior written consent and permission of the
Architect.
CO 2016 Michael Suman Architect, LLC. All rights reserved.