HomeMy WebLinkAboutVail Village Filing 2 Lot E & F (18) ALL BUILDINGS SHEET # SHEET NAME REV. # DATE OWNER VAIL VALLEY MEDICAL CENTER 1 . THE CONTRACTOR SHALL MAINTAIN THE EXISTING STRUCTURAL AND FIREPROOFING APPLICABLE BUILDING CODES - - ARCHITECTURAL 181 WEST MEADOW DR., SUITE 100 INTEGRITY THROUGHOUT THE ENTIRE PROJECT.PROVIDE ELECTROLYSIS PROTECTION AO.0 GENERAL INFORMATION VAIL, COLORADO 81657 BETWEEN ALL DISSIMILAR METALS, WHERE THEY OCCUR. 2003 INTERNATIONAL BUILDING CODE A1 .0 DEMOLITION PLAN CONTACT: RYAN MAGILL (970 904-0066) 2003 INTERNATIONAL MECHANICAL CODE _ - A2.0 FLOOR PLAN, REFLECTED CEILING PLAN, WALL TYPES, DOOR ELEVATIONS 2. THE CONTRACTOR SHALL VISIT THE SITE AND BECOME COMPLETELY FAMILIAR 2003 INTERNATIONAL FIRE CODE DOOR DETAILS AND DOOR SCHEDULE ARCHITECT DAMS PARTNERSHIP, P.C. WITH ALL EXISTING CONDITIONS IN THE AREAS OF CONSTRUCTION PRIOR TO 2003 INTERNATIONAL PLUMBING CODE 0225 MAIN ST., UNIT C101 STARTING WORK. EDWARDS, COLORADO 81632 2002 NATIONAL ELECTRIC CODE PHONE: (970) 926-8960 COORDINATE THE FOLLOWING WITH THE OWNER AND PROVIDE SCHEDULE Archlt tS MECHANICAL FAX: (970) 926-8961 INDICATING PROJECT PHASING, UTILITY SHUTDOWNS, SITE ACCESS, AND TEMPORARY MO MECHANICAL COVER SHEET CONTACT: SCOTT NEVIN, AIA UTILITIES. LIFE _SAFEW SYSTEMS: AUTOMATIC SPRINKLER SYSTEM AND DETECTORS THROUGHOUT M 1 MECHANICAL PLAN 4. THE CONTRACTOR SHALL CONTACT THE OWNER A MINIMUM OF FOURTEEN DAYS - g - MECHANICAL ELECTRICAL MKK CONSULTING 7350 E.CONSULTING ENGINEERS PRIOR TO COMMENCING DEMOLITION TO SCHEDULE SS PLACE, SUITE 100 ALL CONTRACTOR H EN L EWOOD0,3 CO©R 6600 01 1 1 PROVIDE NOTICE TO PERFORMED BY OWNER, UTILITY SHUTDOWNS. ALL UTILITY - OCCUPANCY TYPE AND CONSTRUCTION: PLUMBING ( ) SHUTDOWNS TO BE OCCU"IDANCY: 1-2 P1 PLUMBING PLAN FAX: (303) 721 -0200 2301 BLAKE ST., STE. #1100 - 5. THE CONTRACTOR SHALL KEEP PREMISES FREE FROM ACCUMULATION OF WASTE 0 CONSTRUCTION TYPE: I _ CONTACT: MECHANICAL-RANDY RINKER, P.E. DENVER, COLORADO 80205 EXISTING BOSF: 169,766 S.F. ELECTRICAL-DANIEL P. GRANT, P.E. MATERIALS AND DEBRIS THROUGHOUT THE ENTIRE BUILDING AREA AND PROVIDE 303.861.8555 F.303.861.3027 - CC TENANT IMPROVEMENT : 723 S.F. ELECTRICAL DUST BARRIERS. 0225 MAIN STREET . UNIT C101 0 _ EO ELECTRICAL COVER SHEET 6. DIMENSIONS OF AND FROM EXISTING CONDITIONS HAVE BEEN TAKEN FROM EDWARDS, COLORADO 81632 Um OCCUPANT LOAD: 8 _ -_ E1 DEMO AND NEW ELECTRICAL PLANS AND DETAILS A�P���E� SHALL FIELD DRAWINGS AND/OR DIMENSIONS MEASUREMENTS,N O E STICNOG RACTOT CONDITIONS PRIOR 970.926.8960 F.970.926.8961 LIAM -- - - - — OAIL Community Development Department TO THE START OF CONSTRUCTON. CALCULATED BASED ON THE OCCUPANCY FACTOR 100SF/PERSON PER 2003 IBC ��T Building Safety and Inspection Services TABLE 1004.1 .2, THE OCCUPANT LOAD IS LESS THAN 50. DOORS MAY SWING IN. TOWN 7. DIMENSIONS LOCATING NEW CONSTRUCTION ARE TO FINISHED FACE OF GYPSUM ONE INTERVENING ROOM IS ALLOWED PER 2003 IBC 1013.2 EXCEPTION #4 Section 1051If BOARD. (UNLESS NOTED OTHERWISE). DIMENSIONS LOCATING EXISTING - - International Building Codelinternational Residential CONSTRUCTION ARE FROM EXTERIOR FINISHED SURFACE. - Code Validity of permit. The issuance or granting of a permil shall (UNLESS NOTED OTHERWISE). not be construed to be a permit for,or an approval of, any violation of any of the provisions ct This code or of any other ordinanco of the jurisdiction. Permits presuming to give authority to violate or cancel the 8. CONTRACTOR SHALL PROVIDE SHEET METAL BLOCKING IN WALLS TO RECEIVE provisions of this code or other ordinances of the jurisdiction shall not be ALL ATTACHED EQUIPMENT, OWNER SUPPLIED CASEWORK, ETC. valid. The issuance of a permit based on construe"ion documents and other data shall not prevent the building official from requiring the 9. PATCH ALL EXISTING FLOORS, WALLS AND CEILINGS TO MATCH EXISTING Correction of errors in the construction documents and other data.The MATERIALS AND FINISHES WHERE DISTURBED BY CONSTRUCTION ISSUE/REVISION DATE NO. building official is also authorized to prevent occupancy or use of a REFER TO MECHANICAL DRAWINGS FOR PLUMBING AND HVAC . structure where in violation of this code or of any other ordinances of ( ) this jurisdiction. CONSTRUCTION DOCUMENTS 5/6/05 10. THE GENERAL CONTRACTOR IS TO COORDINATE ALL WELDING VENTING, AND TIMES PLANS EXAMINER: QATE: OF DEMOLITION AND CONSTRUCTION WITH THE OWNER. 11 . ERECT AND MAINTAIN DUST-PROOF PARTITIONS AND CLOSURES AS REQUIRED AND OUTLINED BY THE HOSPITAL TO PREVENT SPREAD OF DUST, NOISE AND PARTICIPANTS p FUMES TO OCCUPIED PORTIONS OF THE BUILDING AND TO PROVIDE FREE AND G01-0)CODE INFORMATION C)SHEETINDEX 00 PARTICIPANTS SAFE PASSAGE OF PERSONNEL AND GENERAL PUBLIC TO AND FROM OCCUPIED PORTIONS OF THE BUILDING. 12. GENERAL CONTRACTOR TO PROVIDE PROTECTION FROM DAMAGE DURING DEMOLITION AND CONSTRUCTION WORK TO FLOOR AND FINISHED SURFACES TO REMAIN. CONTRACTOR SHALL MINIMIZE INTERFERENCE OF CONSTRUCTION WITH ONGOING BUSINESS. CONTRACTOR TO CONTACT OWNER A MINIMUM OF SEVEN DAYS PRIOR TO COMMENCING DEMOLITION TO SCHEDULE WORK. EXISTING 13. ANY MISCELLANEOUS ITEMS OR MATERIALS NOT SPECIFICALLY NOTED, BUT EX IT REQUIRED FOR THE PROPER EXECUTION OR INSTALLATION, OR PERFORMANCE _ -/`_`- - _ - OF THE WORK, SHALL BE PROVIDED BY THE CONTRACTOR, THE CONTRACTOR EXISTING 2 HR FIRE/SMOKE WALL - SHALL PERFORM HIGH QUALITY, PROFESSIONAL WORK, MATERIALS SHALL BE W/ 90 MIN. DOORS- X-RAY JOINED IN A MANNER TO PROVIDE A UNIFORM, ACCURATE FIT; WITH NEAT _ 6 ROSH STRAIGHT LINES, FREE OF SMEARS OR OVERLAPS. INSTALL EXPOSED MATERIALS / sTnPArE IP..UMAi ROOM L� APPROPRIATELY LEVEL, PLUMB, AND AT ACCURATE ANGLES, OR FLUSH WITH - EXISTING 2 HR SHAFT WALL a LJME"T „ X-RAY 4 LEI-] ADJOINING MATERIALS. E=XISTING SMOKE COMPARTMENT E�R= READIN ' IOC — i R T RA AN IN RIN RAWIN 17,613 SF, TYPE I CONSTRUCTION _ �_____--� 14. AOCHT ECTOR SHALL D EONG EE ARCHITECT OF ANY SPEIC F GATIONS,SORE EXESTING �� _ ..__— COPPIDOR CONDITIONS. // NEVIN '( �' l � f'� j MR) T. i05 120 VISCUG 1 R; RM 202985 " •// / � ` ILET PAT NT RppM `\ iS ® �y / _ CLEAN ru�a?R AR ® �_ STATION LOUNGE Sr EF TF U' ; orIL Ul'ILfr 5-0-51 x-RAY LQ� TREATMENT ULTRA- -...._a_- l-1 / - DACT ,/ LAB ; F l�,M PRCICE. OFFICE o o PAT IEN CSI _ (DGENERAL NOTES UILET o b EXAM ;r0 DRESS Tp(L. Rl7L7M / / _ READ/ ER ���,/] D.A4D t STUR i MR1! NURSE MAMHp i% SWITCHED VS�HED OFFICE -ry L—I NUCLE.-AR WORK W WAIL `., - , -__ - , _ ,; '` , �_ _ E DYCINE - ILE RM EXAM .t__..... / GFEIi:E i J MCI I'I P130H oPF a /' / / M (_ I— _I. REGISrRnrinN � I [...__ /r Fro►rtoge Rd Z UJ LIMIT OF `CONSTRUCTION --/ ,�/ / -- — 8 - — ry LLI ......_.e. �.._. EXISTING 1 HR FIRE WALL / i % t TOIL. MECH 70 fio le CrI Z 0 W 20 MIN DddR 7 (\� LpBBY i LOBBY SOUND o SCAN I ROOM +/�` / I 'VE:ST. E X"I S 'V' � � '� /i � 139 136 a TRENCH 131 L I � �/b�tq ' J i! / .` 9Bf/ LLB n _ $ f` // • OPEN TO iCFtAGF wafT CONSOLE F� fOrl ttl ABOVE 13a CORP. Meodow Dr - �� 133 00 ST GE ?i NP / _ _ -. _ ^ 11nCOdG �u`1� W ( J _- L'TINGE LpUNGE CQRR f OOR V 0"MEP / ROCKER f / / ERT 0 109 129 h@4 PJ s WiRSERY MECH. RECOVERRY �I/p 1..0 NuR,FRY ll3 ... 130 0 rufL. T L.� STAR. STOR. NIIRSET�r "`�rrJFK li}I w - .1.09 110 L--JI l72 CLOSET - 111 IL i i 114-A CRASH - F CES 617<1HLi. i i I. AR'T JANITOR /CAST - _' PT / - I� ;� _ CORRIALIR �. Ri➢ CORRIDOR LABOR NORTH 7- r_/ // L ❑f7H RECOVERY / CAST � 126 � N3 ! us Ito ROOM 'LC / A - ,� i //' / •' _ __..� 1 :I 123 NURSF. CLEAN-UP STAFF CLEAN YIti 1.11UNGE UTILITY ST. R 126 NOPSE - RECOVERY (DVICINITY MAP T Q \X/ , / / ' / / / / .s T 125 SOIL TU9 RM P TAT lON 119 i / /' \ I-S.T� // / f '�- // /% i' /// { IL. / '� 1� // 1 72d l21 tl9 J t15 /l �� ` ��: 17Ff"ICE. � LINEM- .i 11..11 EXIT ;; I _.Y._ __�__` /; / ,:/ i j -ry.,_7 -.:_:- 12 _._ �... ......._.._....._.._..,_ STUR. • - / / f \ - ;. XAM / PAM / EXAM ' /i � �HERAP f ,•. � A CGRRiDUR iOT�E SHUhfER P P EXIST I EXIT 100 ton tl9 Riga FILE r xA = ` ' 1 ROOM / ,' ,./ / / H QAP -� IL _ �� W ;SLA PROCEDURE STpR EXAM EXAM, �. .` ,(i5'H / T ON Y / F l: i C-__ ..__ _ .._..1 L. PT sue srER. POiT POST PATIENT PATIENT RS-b GENERAL INFORMATION THERn. k2AD / M[Dr' FA:T�IIM PARTUM ROOM RO➢M I_DR TYF'FICE UFF CE % _ / / /'r_ /D ECTOR `lrb 105 l0a 103 102 % /' / / LnR 9CFIGE .DICE MERAPY �✓ F,: OOH ;, ,. � __'�'..._� , / �,` AREA OF WORK DATE 6 MAY 2005 ............ DRAWN BY BP CHK'D BY CD, SN H SHEET FILE AO.Odw I I _ g COPYRIGHT 2002 BY DAVIS PARTNERSHIP P.C., ARCHITECTS H H H H H L— �' SHEET NUMBER: 50 LIFE SAFETY PLAN @KEY PLAN D.P.A. PROJECT # 05923.00 8 i e 0 — 3 a s r H II I I Ill III Il IIIIIII1111I111III DEMOLITION PLAN KEY NOTES :T 1 , REMOVE MIXER / VALVE/ CONTROLS ww .w ww ww ww ww ww�ww wr ���/// C K E R ❑ C K E R ! O2 REMOVE ELECTRICAL DISCONNECT BOX . ❑M R❑❑M __i : v I S: I 2 1 ' q OFFICE Archit is LIMIT OF � $ I O REMOVE / CAP DRAIN CONSTRUCTION ! 7 ; 8 i - � < 4 � REMOVE DOOR HYDRO 3 ' ' 7 1 ' , THERAPY 4 ; ; - <s> REMOVE CASEWORK & BASE 2301 BLAKE ST., STE.#100 -------- �- DENVER, COLORADO 80205 -- --'-----------------i' ------- ---- � 303.861.8555F.303.861.3027 1 ------------ ---- - ' SHOWER 6 REMOVE SLIDING GLASS DOOR AND TRACK EDWARDS,COLORADO 816321 970.926.8960 F.970.926.8961 ! 6 f O7 REMOVE FLOORING AND WALL TILE AS REQUIRED. ! "PREPARE SURFACE TO ELIMINATE UNEVENNESS THAT 1 COULD TELEGRAPH THROUGH CAUSING PREMATURE 3 AND UNEVEN WARE TO NEW FLOORING. w�...w w •��' , , < 8 � REMOVE GYPSUM BOARD CEILING ASSEMBLY O 11 TI T 7! --- ---- - --- - ----J r 5 ' ' 1 9 REMOVE CEILING GRID AND TILE __ _ 5 i -_--- ISSUE/REVISION DATE NO. P T "� O I ' L J 10 REMOVE GYPSUM SOFFIT -- ---- ---- -, , I , 4 , OFF � r r I 3 CONSTRUCTION DOCUMENTS 5/6/05 1 I , 5 41 1 11 REMOVE FLOORING , 9 I 1 - -- PT DEMOLITION GENERAL NOTES OFFICE " 1 „ 1. WHEREVER PLUMBING FIXTURES, PIPING, ELECTRICAL FIXTURES I ' ' & MECHANICAL EQUIPMENT IS REMOVED, ALL PIPING AND/OR ' CONDUITS THAT ARE ABANDONED SHALL BE CAPPED OFF BELOW „ THE FLOOR, UNLESS NOTED OTHERWISE. ELECTRICAL AND MECHANICAL ITEMS TO BE REMOVED ARE DEFINED ON THE E & - ---- M SERIES OF DRAWINGS. CONTRACTOR TO COORDINATE PROPOSED RELOCATED ITEMS WITH OWNER AND ARCHITECT PRIOR TO INSTALLATION. 2. THE OWNER SHALL BE CONTACTED IN REGARD TO ANY SALVAGEABLE MATERIAL OR EQUIPMENT. ANY SALVAGEABLE ITEMS NOT TO BE REUSED OR WANTED BY THE OWNER SHALL T❑ I BECOME THE PROPERTY OF THE CONTRACTOR. 3. THE GENERAL CONTRACTOR IS TO COORDINATE ALL WELDING VENTING, AND TIMES OF DEMOLITION AND CONSTRUCTION WITH QF THE OWNER AND CONCURRENT OCCUPANCY OF THE BUILDING. DEMOLITION PLAN 4. ALL EXISTING STRUCTURE TO REMAIN. 0 5. GENERAL CONTRACTOR SHALL CAREFULLY REMOVE AND �.o 1 /4" _ ,_0„ INVENTORY ALL ITEMS OF SALVAGEABLE VALUE PRIOR TO SCOTT MICHAEL BEGINNING CONTRUCTION. THESE ITEMS INCLUDE, BUT ARE NOT NEVIN NECESSARILY LIMITED TO: LIGHT FIXTURES r 202985 C>� LIGHT SWITCHES - THERMOSTATS - DOORS HARDWARE ARG�\� I r8%05 -W51-1 wfDitr apo -o - FIRE EXTINGUISHERS (INCLUSIVE OF CABINET) -� - CASEWORK - EXHAUST W�"a`1 '�M�• yll;-D+1�AR N, 5 - ACCESSORIES ANY ITEM BEING RE-USED IN NEW CONSTRUCTION SHALL BE CLEANED AND TESTED (WHEN APPLICABLE) PRIOR TO Z REINSTALLATION. 0 6. CONTRACTOR TO PROVIDE AND MAINTAIN ADEQUATE n/ PROTECTION OF ALL ITEMS AND FINISHES THAT ARE TO REMAIN �L11.•.• FOR THE DURATION OF THE PROJECT. DAMAGED ITEMS OR w - - FINISHES ARE TO BE REPAIRED OR REPLACED BY THE CONTRACTOR AT NO COST TO THE OWNER. < L 7 7. CONTRACTOR TO CAREFULLY REVIEW AND ASSESS THE uj uj VARIOUS SLAB CONDITIONS AND COORDINATE FLOOR PATCHING 0 w AND ADDITIONAL PREPARATION WITH FINISH TO BE INSTALLED. Z U oC O w J ❑ ❑ Q 00 Q ❑ ❑ _j w < 0 w 2 w _ >- C w w J J � Q Q Q � > co Cn J � Q _ > DEMOLITION PLAN DATE 6 MAY 2005 DRAWN BY BP CHK'D BY CD, SN SHEET FILE I A1.0 COPYRIGHT 2005 BY DAVIS PARTNERSHIP P.C., ARCHITECTS SHEET NUMBER: Al ■ D.P.A. PROJECT# 05923.00 PLAN KEY NOTES " HR RATED UL n [ T r I C O1 ADD 5/8" GYPSUM BOARD O EXISTING STUD NON — RATED 1J L 1 U I V l� __ -- WHERE TILE HAS BEEN REMOVED FROM WALLS L❑ r 2 FINISH TRANSITION. BRADCEE DO RU FRAME AS REQUREDUSH . � ROOM ' i ' I - - - I - O3 ICE MACHINE BY OWNER • Archit is LIMIT OF 1 I I I I I I I COORDINATE WATER AND POWER NEEDS FOR EQUIPMENT CONSTRUCTION I I I 1 5 4 IN-FILL WALL AS REQUIRED FROM REMOVAL OF CONTROL I I I I O 3--5/8" 25 GA. STEEL STUDS PANELS TO PROVIDE FLUSH FINISH TRANSITION 3-5/8" 25 GA. STEEL STUDS � I I � I AT 16" O.C. W/ 1 LAYER OF AT 16" O.C. EXTEND FROM 1 J I L J I L I J I OFF I CE 11 5 CASEWORK BY OWNER 5/8" GYP. BD. ATTACHED TO FLOOR TO FLOOR DECK OR I I 2 O 2301 EACH SIDE; EXTEND GYP. BD ROOF DECK W/1 LAYER OF -- -- - --� I I Jai DEN BLAKE LO STE.#100 I I O NEW CUBICLE CURTAINS WITH CEILING TRACK DENVER,COLORADO 80205 6" ABOVE FINISHED CEILING. 5/8" NP. X GYP. BD. ` l 8 303.861.8555 F.303.861.3027 ATTACHED TO EACH SIDE. - - - -- - - - - -- I I r 3 0225 MAIN STREET. UNIT C101 1 7 TREATMENT TABLE / FURNITURE BY OWNER L L EDWARDS,COLORADO 81632 tot 970.926.8960 F.970.926.8961 WALLTYPES 8 6 � 8 CARPET INSET AND BORDER TO MATCH 1 ALIGN ICE O EXISTING ADJACENT CARPET INSET AND BORDER A2.0 1 1 /212 — 1 '-0„ - Q ��-�» 4 IT 2 TREATMENT 1 8 STORAGE i— —_J O GENERAL NOTES ISSUEIREVISION DATE NO. _ CONSTRUCTION DOCUMENTS 5/6/05 5 I r 2 4 1 `-'E 1. NEW BASE TO BE PROVIDED WHERE NEW CARPET DOOR TYPES: Az.0 INSTALLED. PATCH BASE AS REQUIRED AT DOOR 102 3'—On 2" REFER 2" 8 OFF I C E 2 OFFICE 2R0 AND TREATMENT. IN OFFICE 1, STORAGE, TO D N 1 r 2. ALL WALLS TOUCHED BY CONSTRUCTION TO BE II I PAINTED IN THEIR ENTIRETY. 1 I I 3. PROVIDE SHEET METAL BLOCKING FROM 4'-0" LEVER HARDWARE _ A20 1 I O j 2 AFF TO 8'-0" AFF PERIMETER OF STORAGE ROOM. 102 I I I I 4. PROVIDE SHEET METAL BLOCKING AT OFFICE FOR INSTALLATION OF FUTURE UPPER AND LOWER r r L J CASEWORK. - --—�-- -- 5. DOOR ASSEMBLIES IN INTERIOR PARTITIONS ARE 6" -�{--" FROM FINISHED FACE OF ADJACENT PARTITION TO THE JT-J� EDGE OF THE DOOR LEAF UNLESS NOTED OTHERWISE. ALIGN TYPE A TYPE A FLUSH HOLLOW WOOD METAL RAME T ❑ I L_ , 2 DOOR & FRAME ELEVATIONS 3 FLOOR PLAN SCoT A2.0 1 /4" = l '—O" A2.0 1 /419 — 1 1-011 f � !� >F5��11� Srs F�a� O * NEVIN MICHAEL 202985 ARC`���i ONTINUOUS DBL. METAL CRIPPLE STUD Ll H UHALIE HUH STRUCTURAL STUDS I 1 ` AT ET JAMB. WELD I I CAULK REFLECTED CEILING PLAN N TOGETHER AND I, i Z EXTEND TO STRUCT. KEY NOTES CLOSURE TRACK l ! METAL HEAD TRACK DOOR AND FRAME SCHEDULE O UNIVERSAL METAL I DOOR DOOR r� w STUD ANCHORS l I IDENTITY SIZE FRAME .E R L ❑L, E R 1 UAL Ol EXTEND WALL 6" ABOVE GRID � F- CAULK (TYP.) it I CAULK (TYP.) MATL/ RATING d ROOM r 1 ... .EQU L E UA Z w WD HGT THK TYPE LABEL NOTES I I. I . J 2� NEW GRID AND TILE O w HOLLOW MTL. JAMB I HOLLOW MTL. HEAD 101 3'-a" �'-D" 1 3/4" HM. TYPE A -- 1. 5. 6.�4.�AND5 LIMIT O F 1 I �/ TO BE EXTENDED FROM EXISTING GRID 7 ' ` O 102 4'-0" T-0" 1 3/4" HM. TYPE A 20 MIN 1. 2. 3. 1 L V DOOR DOOR CONSTRUCTION r i i•, �, _ ! 3 NEW TILE IN EXISTING GRID w J ❑ ❑ _ NOTES: BI 1. OFFICE LOCKSET 2. ELECTRONIC HOLD OPEN 1 I 4 EXTEND WALL TO STRUCTURE, U 3. CLOSER I 0 EXISTING FIRE RATING TO BE MAINTAINED > O 4. SMOKE SEAL o 5. HINGES 2 5 ❑6. SILENCERS -- __ w(JAMB) HEAD 7. WALL BUMPER r _ - _ _ __ _ - - _ O5 NEW GRID AND TILE ry Q O (HEAD) 1 0 6 1 O CEILING TRACK FOR NEW CUBICLE CURTAINS L l 4 FRAME DETAILS s FRAME DETAILS 6 DOOR SCHEDULE 1 A2.0 1 /42p = 1 ,-0„ A2.0 1 4„ — 1 ,-0" A2.0 1 4„ = 1 ,-0., � � � / / _— t-�-�-- __ - - V 00 IT 1 _ 0 0 T , - FICE 1 FLOOR PLAN & r REFLECTED CEILING PLAN DATE 6 MAY 2005 1 DRAWN BY BP I CHK'D BY CD, SN SHEET FILE A1.0 COPYRIGHT 2005 BY DAMS PARTNERSHIP P.C., ARCHITECTS T ❑ I L, SHEET NUMBER: 7 NOT USED NOT USED 9 NOT USED 10 REFLECTED CEILING PLAN A200 A2.0 A2.0 D.P.A. PROJECT# 05923.00 NOTE: ALL SYMBOLS SHOWN ON LEGEND Archit is MECHANICAL LEGEND ARE NOT NECESSARILY USED ® GENERAL NOTES CFOR ALL MECHANICAL DRAWINGS) PIPING PLUMBING 1. ON DEMOLITION PLANS EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE HW5 — HEATING WATER SUPPLY - DOMESTIC COLD WATER SHOWN HEAVY LINE WEIGHT. EXISTING MECHANICAL SYSTEMS TO REMAIN ARE INC . SHOWN LIGHT LINE WEIGHT. ON ALL OTHER PLANS NEW MECHANICAL SYSTEMS HM — HEATING WATER RETURN -- DOMESTIC HOT WATER M KK CONSULTING ENGINEERS , I N C . ARE SHOWN HEAVY LINE WEIGHT. CW5 CHILLED WATER SUPPLY ---'III- DOMESTIC HOT WATER ( TEMP. SHOWN ) -- 2. THE INSTALLATION OR REMOVAL OF DUCTS, PIPES AND EQUIPMENT MAY 2301 BLAKE ST.,STE.#100 cWR CHILLED WATER RETURN —---— DOMESTIC HOT WATER CIRCULATING Mechanical, E 1 e c tri c a 1 & Energy Consultants REQUIRE THE REMOVAL OF EXISTING WALLS AND CEILINGS. THE CONTRACTOR DENVER, COLORADO 80205 SHALL BE RESPONSIBLE FOR PATCHING AND REPAIRING THESE WALLS AND/OR 303.861.8555 F.303.861.3027 — CS — CONDENSER WATER SUPPLY T TEMPERED WATER CEILINGS SO THEY MATCH THE EXISTING WHERE NOT REPLACED UNDER 0225 MAIN STREET . UNIT C101 NP NON-POTABLE WATER 7350 East Progress Place, Suite 100 ARCHITECTURAL DIVISION. EDWARDS,COLORADO 81632 -- CR — CONDENSER WATER RETURN g 960 F.970.926.8961 CHS — DUAL TEMPERATURE SUPPLY NG NATURAL GAS Englewood, Colorado 80111 3. ALL FIXTURES AND EQUIPMENT REMOVED. AND NOT REUSED, ARE TO BE 970.920.8 (303) 721-6600 RETURNED TO OWNER. CHR — DUAL TEMPERATURE RETURN PLUMBING VENT PIPE www.mkkeng.com 4. PATCH OPENINGS (AIR TIGHT) IN DUCTS WHICH ARE TO REMAIN ACTIVE AND D DRAIN PIPE CHV CHEMICAL VENT PIPE HAVE HAD A SECTION REMOVED. ALSO REPAIR DUCT INSULATION SO THAT w SANITARY WASTE PIPE 500 West 18th Street, Suite 200 175 N. 27th St., Suite 902 IT IS CONTINUOUS. Cheyenne, Wyoming 82001 Billings, Montana 59101 VAC — VACUUM PIPE (307) 634-7647 (406) 256-1141 5. INFORMATION ON THE DRAWINGS HAS BEEN ASCERTAINED FROM EXISTING DRAWINGS AND FIELD OBSERVATIONS. THIS INFORMATION IS AS ACCURATE AS CONDITIONS WOULD ALLOW. IT IS THE RESPONSIBILITY OF THE ]/ALVES & SPECIALTIES HVAC DUCTWORK 827 Rood Avenue CONTRACTOR TO VISIT THE SITE, PRIOR TO BID. AND BECOME FAMILIAR Grand Junction, Colorado 81501 WITH THE EXTENT OF THE REMODEL WORK REQUIRED, NO EXTRAS WILL O (970) 245-3177 BE ALLOWED FOR ALTERATIONS OF A FORESEEABLE NATURE REQUIRED TO FLOW INDICATOR FIRE DAMPER ACHIEVE THE END RESULT AS INDICATED BY CONTRACT DOCUMENTS. ISSUE/REVISION DATE NO. SHUT-OFF VALVE ®S SMOKE DAMPER ® ® 6. CONTRACTOR TO SEAL ALL AUDIBLE AND VISIBLE LEAKS ON ALL REUSED SUPPLY CONSTRUCTION DOCUMENTS 5/6/05 1 �Dll*-- GLOBE VALVE DUCTWORK. OCOMBINATION FIRE / SMOKE DAMPER � CHECK VALVE 7. CONTRACTOR IS TO PROVIDE COMPLETE CONNECTIONS TO ALL NEW AND RELOCATED OWNER FURNISHED EQUIPMENT, FLOW CONTROL VALVE W/ CHECK FF TUR NING VANES SHOWN IN 90' ELBOW. 8. ALL PIPING AND DUCTS INDICATED TO BE REMOVED UNDER THIS CONTRACT PLUG OR BALANCING SHUT-OFF VALVE SHALL BE REMOVED COMPLETELY TO POINTS OF CONNECTION AT THE MAINS OR BRANCHES AND CAPPED. N.O. VALVE W/ LOCKING COVER I OPPOSED BLADE DAMPER ( O.B.D. ) A 013RE1/1ATIONS ALBS OR POUNDS AFF ABOVE FINISHED FLOOR LF LINEAR FEET 9. WORK UNDER THIS CONTRACT IS IN OCCUPIED SPACES, STORAGE ROOMS AND PLUG OR BALANCING SHUT-OFF VALVE IN RISER DUCT SIZES ARE OUTSIDE SHEET METAL EQUIPMENT ROOMS. CONTRACTOR IS TO SCHEDULE AND COORDINATE THE AFG ABOVE FINISHED GRADE LRA LOCKED ROTOR AMPS WORK AND ANY EXISTING EQUIPMENT DOWNTIME WITH THE OWNER OR PROPERTY SHUT OFF VALVE IN RISER 24/12 DIMENSIONS. 1st NO. IS SIZE OF SURFACE MANAGER PRIOR TO BEGINNING WORK. SHOWN, 2nd NO. IS DUCT DEPTH. ALT ALTITUDE LWT LEAVING WATER TEMPERATURE DRAIN VALVE W/ HOSE END BHP BRAKE HORSEPOWER MAX MAXIMUM 10. CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING, COORDINATE ANY SUPPLY DIFFUSER, ALL DIFFUSERS FOUR-WAY EQUIPMENT DOWNTIME, AND COORDINATE GENERAL WORK SCHEDULE WITH THE STRAINER W/ BLOW-OFF VALVE I U THROW UNLESS NOTED OTHERWISE. BTU BRITISH THERMAL UNIT MCA MINIMUM CIRCUIT AMPS OWNER. C COMMON PORT MBH BTU PER HOUR (THOUSAND) 11. THE DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF THE EXISTING MOM TEMPERATURE CONTROL VALVE, 3-WAY SECTION THRU SUPPLY AIR DUCT. EQUIPMENT LOCATIONS, EXISTING PIPE ROUTING AND EXISTING DUCT ROUTING. Cv COEFFICIENT, VALVE FLOW MIN MINIMUM CONTRACTOR IS TO INSTALL NEW EQUIPMENT, DUCTS, AND PIPING IN LOCATIONS SECTION THRU OUTSIDE AIR INTAKE REQUIRED TO AVOID INTERFERENCE WITH EXISTING FACILITIES, EQUIPMENT; DUCTS �rt,. TEMPERATURE CONTROL VALVE, 2-WAY CU FT CUBIC FEET NC NOISE CRITERIA RETURN AIR OR EXHAUST DUCT. AND PIPING. CONTRACTOR 15 RESPONSIBLE- FOR RAISING AND LOWERING � `�� •=•� ' .__ PRESSURE REDUCING VALVE GU IN CUBIC INCH N.O. NORMALLY OPEN y \h• ``f EXISTING EQUIPMENT AND MAKING PROPER OFFSETS IN DUCTS AND PIPING -,,�`'.•°"" TO AVOID CONFLICTS. .�' SAFETY OR RELIEF VALVE OA, RA OR EXH DUCT DOWN CFM CUBIC FEET PER MINUTE N.C. NORMALLY CLOSED .. 12. CONTRACTOR SHALL VISIT THE SITE BEFORE SUBMITTING BID, AND VERIFY SCFM CFM STANDARD CONDITIONS N/A NOT APPLICABLE DIMENSIONS AND EXISTING CONDITIONS RELATED TO THE WORK. t SUPPLY AIR DUCT DOWN 1 AIR VENT dB DECIBEL NIC NOT IN CONTRACT 13. ALL EXISTING EQUIPMENT AND MATERIALS CALLED TO BE REMOVED UNDER THIS ` `•� f CHANGE OF ELEVATION JUP(UP) DOWN (DN)j IN DCW DOMESTIC COLD WATER NTS NOT TO SCALE CONTRACT SHALL BE REMOVED FROM OCCUPIED SPACES DAILY, `'' PRESSURE - TEMP. TAP UP �`- �' DIRECTION OF AIR FLOW DEG OR ' DEGREE NO NUMBER 14. A CUTTING, PATCHING AND CORE DRILLING FOR THE INSTALLATION OF NEW r� ,���. ALL a PRESSURE GAUGE W/ PIG TAIL & COCK EQUIPMENT, DUCTS, HANGERS, ETC. SHALL BE HELD TO A MINIMUM AND BEr�I� FLEXIBLE CONNECTION DHW DOMESTIC HOT WATER OA OUTSIDE AIR ACCOMPLISHED IN A CAREFUL MANNER. ALL PATCHING SHALL MATCH EXISTING ---♦ THERMOMETER -0 I 1 DIA DIAMETER OD OUTSIDE DIAMETER CONSTRUCTION, TEXTURE AND FINISH AND BE DONE BY SKILLED CRAFTSMAN � OF THE TRADES INVOLVED AT THE CONTRACTOR'S. EXPENSE. VACUUM BREAKER DB DRY-BULB PPM PARTS PER MILLION 15. CONTRACTOR TO COORDINATE THE LOCATION OF ALL DUCTWORK, CEILING Z_r_V BACKDRAF7 DAMPER PIPE EXPANSION JOINT DIN DOWN x PERCENT DEVICES, GRILLES, REGISTERS AND DIFFUSERS WITH REFLECTED CEILING 0 PLAN AND STRUCTURE PRIOR TO BEGINNING WORK. FLEXIBLE PIPE CONNECTOR EAT ENTERING AIR TEMP, PH DR � PHASE (ELECTRICAL) EFF EFFICIENCY PSF POUNDS PER SQUARE FOOT 16. DUCT DIMENSIONS GIVEN ARE OUTSIDE SHEET METAL DIMENSIONS. Q FLEXIBLE EQUIPMENT CONNECTOR RETURN AIR GRILLE W/SOUND BOOT W SHADING INDICATES OPEN END ELEV ELEVATION PSI POUNDS PER SQUARE INCH 17. MECHANICAL DRAWINGS ARE DIAGRAMMATIC AND DO NOT NECESSARILY O W PIPE UNION INDICATE EVERY REQUIRED OFFSET, FITTING, ETC. DRAWINGS ARE NOT TO ESP EXTERNAL STATIC PRESSURE PSIA PSI ABSOLUTE BE SCALED FOR DIMENSIONS. TAKE ALL DIMENSIONS FROM ARCHITECTURAL r ! 3 PIPE CAP FLEXIBLE DUCT DRAWINGS, CERTIFIED EQUIPMENT DRAWINGS AND FROM THE STRUCTURE V O EWT ENTERING WATER TEMP, PSIG PSI GAUGE ITSELF BEFORE FABRICATING ANY WORK, VERIFY ALL SPACE REQUIREMENTS W J ❑ ❑ PIPE ANCHOR EXH EXHAUST PRESS PRESSURE COORDINATING WITH OTHER TRADES, AND INSTALL THE SYSTEMS IN THE CONTROLS SPACE PROVIDED WITHOUT EXTRA CHARGES TO THE OWNER. PIPE GUIDE F FAHRENHEIT RA RETURN AIR 18. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S = 0 a 0 THERMOSTAT/SENSOR FLA FULL LOAD AMPS RECIRC RECIRCULATE SAFETY PRECAUTIONS OR TO MEANS, METHODS, TECHNIQUES. CONSTRUCTION ❑ FIRE PROTECTION SEQUENCES, OR PROCEDURES REQUIRED TO PERFORM HIS WORK, a W ❑ O aT N NIGHT THERMOSTAT FPM FEET PER MINUTE RH RELATIVE HUMIDITY < Q OH HUMIDISTAT/SENSOR 19. CODES, LOCAL CODES AND OWNERS STANDARDS INDICATED BY THE CONSTRUCTION W 2 W V FLOW SWITCH FPS FEET PER SECOND RLA RUNNING LOAD AMPS FT FOOT OR FEET RPM REVOLUTIONS PER MINUTE DOCUMENTS. W >_ 2 F.A. FIRE ALARM ® STARTER = FU FIXTURE UNITS SL SEA LEVEL 20. ALL EXTERIOR WALL AND ROOF PENETRATIONS SHALL BE SEALED WATERPROOF. W - � � F FIRE PIPE PRESSURE SWITCH GA GAUGE SENS SENSIBLE J Q 0 I`Z30 EXISTING FIRE SPRINKLER J GAL GALLONS STD STANDARD �DIFFERENTIAL AIR PRESSURE SENSOR > co ~b EXISTING FIRE SPRINKLER TO BE RELOCATED GPH GALLONS PER HOUR SP STATIC PRESSURE V r' r O NEW FIRE SPRINKLER Q SWITCH GPM GALLONS PER MINUTE SA SUPPLY AIR (n m Q n EXISTING FIRE SPRINKLER TO BE REMOVED FLOW METER HD HEAD TEMP TEMPERATURE HG MERCURY TD TEMPERATURE DIFFERENCE O.S. & Y VALVE a � LT LOW LIMIT THERMOSTAT HGT HEIGHT TSP TOTAL STATIC PRESSURE -� HORZ HORIZONTAL TSTAT THERMOSTAT - SHUT--OFF VALVE W/TAMPER SWITCH TEMPERATURE CONTROL (T.C.) DAMPER HP HORSEPOWER TONS TONS OF REFRIGERATION o FIRE DEPARTMENT CONNECTION-WALL TYPE HR HOUR(S) VAV VARIABLE AIR VOLUME SD HWC HOT WATER CIRCULATING (DOMESTIC) VEL VELOCITY MECHANICAL MISCELLANEOUS ANEo_us_ SMOKE DETECTOR (DUCT) __j IN INCHES vERT VERTICAL o' COVERSHEET a POINT OF DUCT CONNECTION NEW TO EXISTING IN W.C. INCHES WATER COLUMN V VOLT © CIRCUIT TRANSFORMER KW KILOWATT VOL VOLUME T A SECTION CUT: (A) SECTION I.D. (1) SHEET NO. WHERE SHOWN. a PRESSURE DIFFERENTIAL SENSOR KWH KILOWATT HOUR W WATT OR WASTE DATE 6 MAY 2005 g c� POINT OF PIPE CONNECTION NEW TO EXISTING LAT LEAVING AIR TEMPERATURE WB WET-BULB DRAWN 13Y MIU w U.C. 1 UNDERCUT DOOR, 1". CHK'D BY NGA o SHEET FILE WMCPT-M1.DWG 0 COPYRIGHT 2005 BY DAMS PARTNERSHIP P,C., ARCHITECTS SHEET NUMBER: M 0 MKK PROJECT# P19919 O n m 0 1 E 1 E vls� Pa • Archit is 2301 BLAKE ST.,STE.#100 DENVER, COLORADO 80205 ❑ \ ❑ 303.861.8555 F.303.861.3027 0225 MAIN STREET. UNIT EDWARDS COLORADO 816321 \ \ 970.926.8960 F.970.926.8961 G 11 IL GIFT G GIFT STQRAC:E SHOP ST ORAGE SH❑P 0 LOCKER LOCKER � ROOM - � L❑CKER L❑CKER _ 40/24 YIiR❑ 36/24 R❑flM um 40/24 36/2 ' 12/12 1 jL ' B 150 - 9x9 ISSUE/REVISION DATE NO. 10/14 - 22/18- 12/12 1� 140 ION »� �--IA 0/ — 14/10 C 102 _ 9x9 90 22/18 CONSTRUCTION DOCUMENTS 5/6/05 1 6 - , IN fi 40 50 22 18 22 14 / 8/8 ' �� 7 10 34 10 10 12 I T 9 0 _ _ _ I 10/12 IT PT I1I 6 0 x6 ❑� 8/10 PTLIC ICE PT 9"� 65 6 22/14 / II [IF /� 6/6 _9x9 1 fi 125,� , 10/ 12 fi 7 I 16/12 4 9X9 1022 H -- pH� -�' 10/ - - 65 0 6 1250 T❑IL. H - 1 H -7 10/ 46/24 ❑IL. 46/24 0. SCALE; 1/8" = 1'-0" ' 8' 0 8' 16' SCALE: 1/8* = V-0" ° , 0 16 �v,i�L.,—.i,-_-.,•_°',� ...eta(: FL69 _NOTES: C- FLAG NO,, S: 0 Z o � 1. CONTRACTOR TO VERIFY PROPER OPERATION AND BALANCE OF 1. 0--1 LOUVERED FACED DIFFUSER, TYP. DIFFUSER TO BE TITUS EXISTING SYSTEMS TO BE MODIFIED AS PART OF THIS PROJECT. MODEL TDC WITH SQUARE NECK DIMENSION AS SHOWN ON DWG. W ANY PROBLEMS SHOULD BE IMMEDIATELY REPORTED TO OWNER AND ENGINEER. 2, RG_2 PERFORATED FACE RETURN GRILLE, TYP. RETURN GRILLE TO > Z W BE TITUS PAR NECK SIZE AS SHOWN ON DWIG. O W 3. EG-3 EXHAUST GRILLE, TYP. EXHAUST GRILLE TO BE TITUS 23-RL Z U Q NECK SIZE AS SHOWN ON DWG. w ❑ 0 4. ROUND DUCT TAKE-OFF, TYP. REFER TO DETAILS J FLAG NOTES: C� � rQ� � 5. 45-TAKE-OFF, TYP. REFER TO DETAIL A. V 1. REMOVE EXISTING DUCTWORK AS SHOWN, TYP. CAP DUCTS AT = O O MAIN. 6. RELOCATED THERMOSTAT SAVED FROM DEMOLITION, a W 0 J 2. FIELD VERIFY LOCATION OF EXISTING THERMOSTAT SERVING 7. INSTALL NEW RETURN GRILLE. REBALANCE RETURN TO CFM SHOWN. Q Q O G EXISTING DHC-1 WITH-IN SPACE. REMOVE THERMOSTAT AND IF NO MEANS OF BALANCING EXISTS AT REGISTER OR DUCT w SAVE FOR RELOCATION DURING NEW CONSTRUCTION. CONTRACTOR TO INSTALL NEW BALANCING DAMPER. W >- 2 W F_ J � Q J Q � > a Q o0 a co r 00 USE GASKETED FITTING. USE DUCT SEALANT OR Q a ATTACH PER MANUFACTURER'S GASKETED FITTING. a 1�4" RECOMMENDATIONS. 6 MINIMUM. LATERAL TAKE-OFF FITTING ROUND TIMST-IN FITTING V' W/ MANUAL DAMPER, HANDLE,MANUAL NUT. HANDLE, & LOCK NUT, 45' FLEX DUCT FLEX DUCT 0 i 0 a! ce �_ � MECHANICAL 00, a WORM DRIVE S.S. a WORM MP (ON INNER MANUAL VOLUM CLAMP (ON INNER LINER). PLAN DAMPER. `� uNER) DELETE MANUAL DAMPER SEAL AIRTIGHT WHEN UPSTREAM OF VAV BOX. � AROUND ENTIRE DATE 6 MAY 2005 45" DUCT-TAKE—OFF TAKE-OFF. LATERAL TAKE-OFF FITTING SPIN-IN FITTING DRAWN BY WU NO SCALE D ROUND DUCT TAKE—OFF FITTINQS B CHK' 8Y NGr4 O NO SCALE SHEET FlLE WMCPT-M1.DWG D_ COPYRIGHT 2005 BY DAMS PARTNERSHIP P-C.. ARCHITECTS SHEET NUMBER: m 1 a MKK PROJECT# P19919 o_ m 0 I E 1 E FLAG NOTES: 0 GENERAL NOTES: vis 1. REMOVE EXISTING FLOOR DRAIN AND 1. SPECIFIC SPRINKLER PIPE ROUTING AND SPRINKLER HEAD LOCATIONS Pa A is ASSOCIATED WASTE PIPING BACK TO MAIN, SHALL BE PER THE FIRE PROTECTION CONTRACTOR. CONTRACTOR TYP' SHALL CENTER HEADS IN TILES AND COORDINATE SPRINKLER HEAD �`y 2. REMOVE EXISTING WASTE PIPING AND TRAPS LOCATIONS WITH THE REFLECTED CEILING PLAN. 5 ( E G HYDROTHERAPY TUBS BACK 0 MAIN, TYP r? ry \ I 3. REMOVE VENT PIPING BACK TO MAIN VENT O 2301 BLAKE ST.,STE.#100 RISER AND CAP. CONTRACTOR TO FILED DENVER, COLORADO 80205 ❑ VERIFY COORDINATE VENT PIPING TO BE 1. ROUTE NEW 1/2" DCW LINE TO VALVED 1/4" STUBOUT FOR 303.861.8555 F.303.861.3027 REMOVED BEYOND WHAT IS SHOWN ON CONNECTION TO ICE MACHINE. TIE INTO EXISTING DCW PIPING IN PLANS, TYP. G ❑ CHASE. GIFT — " " � — — _ — — _ — _ — " ED RD STREET. UNIT 6 2 STAGE SHOP 4. EXISTING 3/4 DHWC AND 2 DHW LINES IN EDWARDS,COLORADO 6-8961 2 !I 2. � NEW FLOOR DRAIN JOSAM MODEL 30000-A WITH 2 WASTE 970.926.8960 F.970.926.8961 CHASE. I GIFT f CONNECTION. ROUTE NEW 2" WASTE FROM FLOOR DRAIN TO EXISTING 3 1 5. REMOVE EXISTING TEMPERING VALVE CABINET. ST❑RpGE SHOP 3" WASTE LINE. TIE NEW 2" VENT INTO EXISTING VENT LINE BELOW FLOOR. COORDINATE FLOOR DRAIN LOCATION SHOWN ON ARCH PLANS LOCKER LOCKER 4" F.C.O. TYP. I AND EQUIPMENT CUT SHEETS. RO❑M ROOM 2" DRAIN > 1 p� 6. REMOVE EXISTING DHW AND DHWC LINES YDR"A' � 4" F.C.O. 3. THE EXISTING FIRE PROTECTION SYSTEM SHALL MODIFIED TO OFFICE FROM TEMPERING VALVE CABINET TO MAIN LOCKE=R L❑CKLR - -- I RISER, TYP. I ROOM ROOM 00 -- ACCOMMODATE NEW LAYOUT OF WALLS AND CEILINGS WITHIN THE -� PROJECT SPACE, PROTECT THE PROJECT AREA WITH AUTOMATIC WET 4" 1 OFFICE SPRINKLER SYSTEM. DESIGN THE SYSTEM BASED ON LIGHT HAZARD 7. REMOVE EXISTING HYDROTHERAPY TUB AND " PER NFPA 13 2002 EDITION USING QUICK RESPONSE ORDINARY = 3" -O TEMPERED WATER CONNECTION, TYP, 0 2 TEMPERATURE (UNLESS SPECIFIED OTHERWISE) ► 2" OVERFLOW 2 V SPRINKLER HEADS WITH THE FOLLOWING DESIGN SPECIFICATIONS: ISSUEIREVISION DATE NO. 3 W— 8. REMOVE EXISTING DCW CONNECTION FROM __ �_ 4" DESIGN DENSITY: 0.10 GPM/SQ. FT. 4" 2" SHORED WATER MIXING VALVE CABINET AS 3" 2" AREA OF OPERATION: 1500 SQ. FT. OR TOTAL AREA WHICHEVER IS � HOSE STREAM DEMAND; 100 GPM CONSTRUCTION DOCUMENTS 5/6/05 1 2 9. EXISTING DCW MAIN. IN 1 I T � I i " �4"PT ,I 3 OFFICE TRH TMENT OFFICE f� OFFICE 4" PT " � 1�2 OFFICE 2 FIFFICF Or � I TOIL. 4" TOIL. I 4" WASTE & VENT PIPING 0EMOLITIOR PLAN SCALE: 1/8" - 1'-0" $' $' 16' NEW PLUMBING SCALE: 1/8" = V-0" 8' 0 8' 16' r � 't-t- )*m4x _ Z 0 � ac w h� �d� - > z w 5 6 o w � Jo ❑ _ - 00 ❑ Q w Qo 2w � GIFT — w >- 2 J STORAGE SHOP 2 w - I 0 I- J Q 0 5 5 J r � LOCKER LOCKER � Q � r Q ROOM ROOM o o r , z HYDRO OFFICE J 0 6 O7 7 o a „ 1 - - -04 3/ 5 Q 3j4 8 1 a cn — 4 6 � IT - - PLUMBING PT " PLAN o OFFICE PT i 2 OFFICE Of OFFICE i ,I 0 D I DATE 6 MAY 2005 - , DRAWN BY MJU z T❑I L. I CH K'D BY NGA o SHEET FILE WMCPT-P1.DWG Of 9 D G COPYRIGHT 2005 BY DAMS PARTNERSHIP P.C.. ARCHITECTS SUPPLY PIPING DEMOLITION ELAN SHEET NUL48ER: SCALE: 1/8' = 1'-0" 8+ 0 8' 16' p 1 MKK PROJECT# P19919 m zw m 0 NOTE; ALL SYMBOLS SHOWN ON LEGEND ® ® GENERAL NOTES (FOR ALL ELECTRICAL SHEETS ELECTRICAL LEGEN2 ARE NOT NECESSARILY USED. 1, THESE DRAWINGS ARE DIAGRAMMATIC. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT DIMENSIONS. COORDINATE LOCATION OF OUTLETS WITH ARCHITECTURAL ELEVATIONS, CASE WORK INSTALLER, AND EQUIPMENT INSTALLER. COORDINATE THE LOCATION OF MECHANICAL EQUIPMENT WITH MECHANICAL PLANS AND MECHANICAL LIGHTING 5QHEMATIC WIRING GRAPHICS MKK C 0 N S U LT I N G ENGINEERS , INC . CONTRACTOR PRIOR TO ROUGH-IN, COORDINATE LOCATION OF LUMINAIRES WITH � � - � Archi t is ARCHITECTURAL REFLECTED CEILING PLANS. 0 DOWNLIGHT ® METER Mechanical, Electrical & Energy Consultants 2. REFER TO ARCHITECTURAL PLANS, ELEVATIONS AN D D IA GR AM S FOR LOCATIONS OF 01 WALL MOUNTED FLUORESCENT OR INCANDESCENT GROUND CONNECTION AS NOTED FLOOR AND WALL DEVICES. LOCATION WILL INDICATE VERTICAL AND/ OR LUMINAIRE, AS NOTED HORIZONTAL MOUNTING. IF DEVICES ARE NOT NOTED OTHERWISE THEY SHALL BE DISCONNECT SWITCH 7350 East Progress Place, Suite 100 MOUNTED AT +18" AFF TO CENTER--ORIENTATION PER HOSPITAL STANDARDS. ® SURFACE MOUNTED FLUORESCENT LUMINAIRE Englewood, Colorado 80111 2301 FUSES (303) 721-6600 3. INFORMATION ON THESE DRAWINGS HAS BEEN ASCERTAINED FROM EXISTING DRAWINGS. DEN BLAKE LO STE.#100 RECESS MOUNTED FLUORESCENT LUMINAIRE �_ www_mkken com THIS INFORMATION IS AS ACCURATE AS CONDITIONS WOULD ALLOW. BEFORE WORK IS DENVER,COLORADO .3027 CIRCUIT BREAKER, MOLDED-CASE, THERMAL-MAGNETIC g' PERFORMED, CIRCUIT TRACE THE EXISTING BRANCH CIRCUITS IN THE AREA OF WORK, 303.861.8555 F.303.861.3027 ® UNDERCABINET FLUORESCENT LUMINAIRE � ! 0225 MAIN STREET .UNIT C101 `} POWER TRANSFORMER 500 West 18th Street, Suite 200 175 N. 27th St., Suite 902 4. ALL 120V BRANCH CIRCUITS SHALL BE 3-WIRE (PHASE,NEUTRAL,GROUND). PHASE, EDWARDS,COLORADO 81632 -� FLUORESCENT STRIP LUMINAIRE Cheyenne, Wyoming 82001 Billings, Montana 59101 NEUTRAL, AND GROUND CONDUCTORS SHALL BE SIZE 12 AWG UNLESS OTHERWISE 970.926.8960 F.970.926.8961 NCH e CEILING OR WALL MOUNTED EXIT SIGN, ® (307) 634-7647 (406) 256-1141 WITH NOT p r BRAG RG CIRCUITS SHOWN AS SINGLE HOMERUN SHALL NOT BE COMBINED INSTALL FACES AS INDICATED BY SHADING FIRE ALARM SYSTEM 5. PROVIDE TYPED, UPDATED PANEL DIRECTORIES FOR ALL EXISTING PANELS AFFECTED POWER FRCP REMODEL WORK. PROVIDE NEW CIRCUIT BREAKER NUMBER IDENTIFICATION AS FIRE ALARM CONTROL PANEL REQUIRED. 0 STRAIGHT BLADE DUPLEX RECEPTACLE FAAP FIRE ALARM ANNUNCIATOR PANEL 6. PROVIDE (1) 3/4"C WITH BUSHING AND PULL WIRE FROM EACH TELEPHONE, DATA SUBSCRIPTS: GFI = GROUND FAULT INTERRUPTER Fn MANUAL PULL STATION T-STAY, OR NURSE CALL OUTLET SHOWN, TO ABOVE ACCESSIBLE CEILING. AC = 6" ABOVE COUNTER FIRE ALARM STROBE 7. MAINTAIN CIRCUIT CONTINUITY FOR ALL EXISTING ITEMS THAT ARE REMAINING OR STRAIGHT BLADE DOUBLE DUPLEX RECEPT. (FOURPLEX) BEING RELOCATED. ISSUE/REVISION DATE NO. GENERAL ALARM COMBINATION HORN/STROBE STRAIGHT BLADE DUPLEX RECEPT. ON EMERGENCY CIRCUIT © 0� CEILING OR WALL MOUNTED DETECTOR ABBREMMIONS 8. ALL NEW WIRING REQUIRED IN REMODELED AREAS SHALL BE FISHED THROUGH CONSTRUCTION DOCUMENTS 5/6/05 1 EXISTING WALLS OR CONCEALED IN NEW WALLS OR ABOVE CEILINGS, SURFACE- I$= DOUBLE DUPLEX RECEPT. ON EMERGENCY CIRCUIT SUBSCRIPTS: MOUNTED CONDUIT SHALL NOT BE USED IN ANY FINISHED AREAS. CONTRACTOR I = IONIZATION NOTE: ALL ABBREVIATIONS SHOWN SHALL NOT ROUTE ANY CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF 0 OUTLET WITH SPECIAL DEVICE, AS NOTED T = THERMAL. FIXED AND RATE-OF-RISE ARE NOT NECESSARILY USED, FLOORS UNLESS NOTED TO DO So, P = PHOTOELECTRIC JO JUNCTION BOX Poi REMOTE PILOT LIGHT AC - ABOVE COUNTER 9. ALL ITEMS SHOWN TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY AFC - ABOVE FINISHED CEILING INCLUDING ALL ASSOCIATED HANGERS, CONDUIT AND WIRE BACK TO POINT OF ORIGIN OR H SAFETY DISCONNECT SWITCH 01 REMOTE PILOT LIGHT WITH TEST SWITCH AFF - ABOVE FINISHED FLOOR NEAREST EXISTING ITEM THAT IS REMAINING, UNLESS OTHERWISE NOTED. WHERE P/T AIC - AMPS INTERRUPTING CURRENT EXISTING DEVICES, SWITCHES, MOTOR CONNECTIONS, ETC, ARE TO BE REMOVED FROM FUSED DISCONNECT SWITCH ® DAMPER CONNECTION CS - CIRCUIT BREAKER WALLS WHICH ARE REMAINING, WALLS SHALL BE PATCHED TO MATCH ORIGINAL FINISH, AFTER CONDUCTORS HAVE BEEN REMOVED. BLANK COVERPLATES OVER CONNECTION TO PRE--WIRED EQUIPMENT CT - CURRENT TRANSFORMER EXISTING BOXES ARE NOT ACCEPTABLE. IF EXISTING CONDUITS ARE ROUTED IN CU - COPPER CONCRETE FLOOR SLABS, WALLS OR CEILINGS, THEY SHALL BE CUT BACK TO WITHIN COMMUNICATION SYSM BREAKER PANEL EM - EMERGENCY CONCRETE AND FILLED WITH GROUT TO ACHIEVE A SMOOTH AND EVEN FINISH FLUSH fig WALL MOUNTED TELEPHONE OUTLET ES - EMERGENCY STOP WITH CONCRETE SURFACE AFTER CONDUCTORS HAVE BEEN REMOVED. FLA - FULL LOAD AMPS 10. ALL EMERGENCY RECEPTACLE DEVICES SHALL BE RED. ALL SWITCH PLATES WALL MOUNTED COMBINATION TELEPHONE/DATA FWE - FURNISHED WITH EQUIPMENT CIRCUITING 0 THAT CONTROL EMERGENCY LIGHTING SHALL BE RED. ALL UPS RECEPTACLE OUTLET BOX GFI -- GROUND FAULT INTERRUPTER DEVICES SHALL BE BROWN. ALL ISOLATED GROUND RECEPTACLE DEVICES CONDUIT RUN H - HORIZONTAL MOUNTING OF DEVICE SHALL BE ORANGE. COVERPLATES SHALL MATCH BUILDING STANDARDS. (S) OS -I CEILING OR WALL MOUNTED SPEAKER HP - HORSEPOWER —�� CIRCUIT HOMERUN TO PANEL OR CABINET, IG - ISOLATED GROUND 11. IN PATIENT TREATMENT AREAS, ALL RECEPTACLES SHALL BE HOSPITAL-GRADE .0 REC/ NO. OF ARROWS INDICATE NO. OF CIRCUITS OA VOLUME CONTROL MCA - MINIMUM CIRCUIT AMPS IN OFFICE-TYPE SPACES, RECEPTACLES ARE PERMITTED TO BE COMMERCIAL-GRADE ���.�`�.P.� CEILING OR WALL MOUNTED CLOCK B MAIN CIRCUIT BREAKER - �--- 0 CIRCUIT TURNED UP Q Q-f DEVICES. MC MCCB - MOLDED CASE CIRCUIT BREAKER 12. PROVIDE 1/4" TAPE LABELS ON ALL RECEPTACLES AND SWITCHES THAT 3£:` —, CIRCUIT TURNED DOWN 51 TELEVISION ANTENNA OUTLET MLO - MAIN LUGS ONLY INDICATES PANELBOARD AND CIRCUIT NUMBER. LABELS SHALL BE BLACK NTS - NOT TO SCALE LETTERS ON WHITE OR CLEAR BACKGROUND FOR NORMAL POWER AND RED OCPD - OVERCURRENT PROTECTION DEVICE LETTERS ON WHITE BACKGROUND FOR EMERGENCY POWER. `rslpNALE�G SC - SHORT CIRCUIT SWITCHING NOTATIONS TTB - TELEPHONE TERMINAL BOARD 13. BACK TO BACK RECEPTACLES OR TELEPHONE JUNCTION BOXES ARE NOT WP - WEATHERPROOF PERMITTED. PROVIDE MINIMUM OF 6" O.C. SPACING BETWEEN DEVICES IN S WALL MOUNTED SWITCH 1 - UPPER CASE LETTER AT LUMINAIRES XFMR - TRANSFORMER NON-SOUND-RATED WALLS AND 24" O.G. IN SOUND-RATED INSULATED WALLS. SUBSCRIPTS: (F1, I1 , ETC.) INDICATES 3 = 3-WAY LUMINAIRE TYPE. F1 = TYPE F1 4 = 4WAY LUMINAIRES IN AREA NDICATED. 14. MAINTAIN FIRE RATINGS FOR ALL CONDUIT PENETRATIONS THROUGH FIRE-RATED Z -- D = DIMMER CONSTRUCTION. O 2 -- LOWER CASE LETTER AT LUMINAIRES AND SWITCHES (a, b, ETC.) INDICATE 15, ALL CONDUIT AND WIRE SHALL BE CONCEALED EXCEPT IN ELECTRICAL ROOMS. W W ASSOCIATED UNITS FOR SWITCHING. NURSE CALL SYSTEM 16. WHERE THE REUSE OF EXISTING CONDUITS, OUTLETS, JUNCTION BOXES, ETC., IS Q Z 3 - SHADING WITHIN LUMINAIRE DENOTES PERMISSIBLE, MAKE CERTAIN THAT THE WIRING OF THEM IS CONTINUOUS FROM O Z W CODE BLUE EMERGENCY STATION UNIT ON EMERGENCY CIRCUIT. OUTLET TO OUTLET AND THAT ALL SPLICES/INSULATION ARE IN GOOD CONDITION. W PROVIDE MODIFICATION TO ASSURE THAT CIRCUITS, OR SYSTEM, SHALL NOT PASS Z HD PATIENT STATION WITH CORD ASSEMBLY 4 - PLUS (+) SIGN WITH DIMENSION AT THROUGH OUTLETS OR JUNCTION BOXES WHICH MAY BE RENDERED INACCESSIBLE W U OUTLET INDICATES HEIGHT ABOVE BY THE CHANGES TO BE MADE TO THE BUILDING. EXISTING EXPOSED CONDUIT/ J ❑ Q MULTI--LAMP NORMAL/CODE BLUE DOME LIGHT FINISHED FLOOR OR GRADE TO CONDUCTORS WHICH ARE NOT TO BE REUSED SHALL BE REMOVED AND ALL CENTERLINE OF OUTLET. BUILDING SURFACES RETURNED TO THEIR ORIGINAL CONDITION. EXISTING r 3 CONCEALED CONDUIT WHICH IS NOT TO BE REUSED SHALL BE ABANDONED IN U PLACE AFTER THE ENCLOSED CONDUCTORS HAVE BEEN REMOVED. EXISTING = — O CONTROLS CONDUITS AND WIRE, ETC., WHICH SHALL BE REMOVED SHALL BECOME THE a- [, PROPERTY OF THIS CONTRACTOR UNLESS NOTED OTHERWISE, W WC 0 G THERMOSTAT 17. CONNECT NEW WORK TO EXISTING IN A MANNER THAT WILL ASSURE PROPER W U RACEWAY GROUNDING THROUGHOUT IN CONFORMANCE WITH THE NATIONAL W >- 2 ELECTRIC CODE. = W J I& ALL NEW AND RELOCATED LUMINAIRES SHALL BE SUPPORTED INDEPENDENTLY F'- J Q OF CEILING SUPPORT HANGERS, IN COMPLIANCE WITH IBC REQUIREMENTS. J r 19, ELECTRICAL CLOSETS SHALL BE KEPT SECURE, CLEAN, AND ACCESSIBLE AT ALL Q 13z:( TIMES DURING CONSTRUCTION. ALL PANEL SCHEDULES MUST BE UPDATED AND V V_PANEL COVERS REPLACED AFTER CONSTRUCTION. -- m 20. ALL ABANDONED WIRING SHALL BE REMOVED FROM DUCTS OR CONDUIT. ALL ABANDONED Q a CONDUITS, INCLUDING EXISTING CONDUITS FOUND DURING CONSTRUCTION, SHALL BE REMOVED BACK TO POINT OF ORIGIN, THIS INCLUDES REMOVING RELATED HANGERS AND SUPPORTS. a Q CIRCUITS NO LONGER IN USE SHALL BE LABELED AS SPARE AND TURN OFF BREAKER. 21. ALL ELECTRICAL WORK SHALL COMPLY WITH THE FOLLOWING CODES AND STANDARDS: NEC (2002), NFPA (70 & 101), IBC/UBC, AND LOCAL CODE o REQUIREMENTS. ELECTRICAL COVER SHEET ZE DATE 6 MAY 2005 DRAWN BY SAR/THU c� ,z CHWD BY DPG 0 SHEET FILE VVMCPT—EO.DWG a COPYRIGHT 2005 BY DAMS PARTNERSHIP P,C., ARCHITECTS SHEET NUMBER: a] EO I) MKK PROJECT# P19919 0 a o, 0 1 E 1 E UCE: MKK CONSULTING ENGINEERS INC. Mechanical, Electrical & Energy Consultants . vis 7350 East Progress Place, Suite 100 } Englewood, Colorado 80111 . Arc h]t (303) 721-6600 • Fax (303) 721-0200 _ www.mkkeng.com 2301 BLAKE ST_,STE.#100 DENVER, COLORADO 80205 \ \ 303.861.8555 F.303.861.3027 0225 MAIN STREET.UNIT EDWARDS,COLORADO 16321 \ F ❑ \ 970.926.8960 F.970.926.8%1 G ❑ C GIFT EXISTING P " ST❑RA.iE SHOP UIET �1 STORAGE SHOP 1 0 LOCKER LOCKER L1 C- ,35 ROOM ROOM E" a D LOCKER R❑❑MER 35 0 OFFICE f RAPY� L1C-22 ISSUE/REVISION DATE NO. `l LJ L"J• rl F2 F2 1 CONSTRUCTION DOCUMENTS 5/6/05 O D o 1 F1 F - I❑N F I❑N 7 _t'T_ o ' LIC-24 IT �' I F Z E (ICE MACH) ❑If 1 IT F3 PT 0 I�1 OFFICE PT iL� OFFICE OFFICE F2 ® ❑EEICE I ® 4 ❑EEICE F2 F I' 2 TO I L. 6 OR o�a'°�O-P ELECTR CAL DEMOLITION PLAN �_0 SCALE: 1/8" = I'-0" NEW ELECTRICA�AN 3528 � 8 0 8 16 SCALE, /8 0 . 8' 0 8' 16' o,��•�� •• ��' GENEEAL NQIES THIS SHEET:- FIRE ALARM NOTES: z 1. REFER TO SHEET EO FOR ADDITIONAL GENERAL NOTES. O N 1. PROVIDE NEW OR REWORK EXISTING SMOKE DETECTORS AS DESCRIBED BY NFPA 72 — LL 2. DEMOLITION PLAN: ALL ITEMS SHOWN HEAVY LINE WEIGHT SHALL BE REMOVED. OR AS DIRECTED BY AUTHORITY HAVING JURSIDICTION. W UNLESS OTHERWISE NOTED. ALL ITEMS SHOWN LIGHT LINE WEIGHT ARE EXISTING TO REMAIN, UNLESS OTHERWISE NOTED. 2. IF NEW DEVICES ARE REQUIRED, VERIFY EXISTING FIRE ALARM SYSTEM IS OPERATING PROPERLY > Z Uj 3. NEW FLOOR PLAN: ALL ITEMS SHOWN LIGHT LINE WEIGHT ARE EXISTING TO REMAIN, AND DOCUMENT ANY DEFICIENCIES PRIOR TO WORK. CONFIRM THAT THERE IS ADEQUATE O W UNLESS NOTED OTHERWISE. ALL ITEMS SHOWN HEAVY LINE WEIGHT ARE NEW CAPACITY ON THE CIRCUITS FOR THIS WORK, UPGRADE THE PANEL AS REQUIRED. COMPLETE > OR RELOCATED, UNLESS NOTED OTHERWISE. THE FIRE ALARM PROGRAMMING AND TESTING OF NEW CIRCUITS AT THE END OF THE z V W 0 4. EXISTING LUMINAIRES THAT THAT ARE REMOVED DURING DEMOLITION SHALL BE CLEANED W J 0 0 AND RETURNED TO THE OWNER. 3. ADA COMPLIANCE: ALL ADA HORN/STROBE UNITS SHALL BE MOUNTED +80" AFF OR LL 6" BELOW FINISHED CEILING, WHICH EVER IS LOWER. ELECTRICAL DEVICES r 3: 5. CIRCUIT TRACE THE EXISTING BRANCH CIRCUITS IN THIS AREA PRIOR TO DEMOLITION PROJECTING FROM WALLS WITH THEIR LEADING EDGES BETWEEN 27" AND 80" AFF U WORK TO FIELD IDENTIFY THAT CIRCUITS NOTED MATCH THE DRAWINGS. SHALL PROTRUDE NO MORE THAN 4" INTO WALKS OR CORRIDORS. ELECTRICAL AND = 0 0 COMMUNICATIONS SYSTEMS RECEPTACLES ON WALLS SHALL BE 18" MINIMUM AFF TO a 0 _j 6. WHERE EXISTING CIRCUIT BREAKERS IN PANEL "L1 C" ARE MADE SPARE DURING DEMOLITION, CENTER OF COVERPLATE. Q W Q 0 PROVIDE NEW 20AIP CIRCUIT BREAKERS FOR NEW BRANCH CIRCUITS THAT MATCH THE NEC LOAD JUSTIFICATION: Ix 2 W 0 PANEL TYPE AND BRACING. 7. EXISTING CONDUITS FROM PANEL 00C" MADE SPARE DURING DEMOLITION CAN BE REUSED PAN " 1 Co _ W • J PROVIDED THAT JOINT COUPLINGS AND BONDING BUSHINGS ARE SECURE FOR AN NEC LOAD JUSTIFICATION: 225A, 120/208V, 30, 4W (VIA 200A FUSES) J EFFECTIVE GROUND PATH. NEW BRANCH CIRCUITS SHALL CONTAIN A COPPER BOND WIRE. " " EXISTING FEEDER IS (4j3/0+#6G)2-1/2"C J p PANEL L1A _j r• 8. EXISTING RECEPTACLES AND SWITCHES ARE PERMITTED TO BE REUSED, PROVIDING THAT 100A, 120/208V, 30, 4W (VIA 100A FUSES) LOAD REMOVED: Q � THE DEVICES ARE NOT WORN, BROKEN, CRACKED, OR CHIPPED AND MATCH THE APPLICATION. EXISTING FEEDER IS (411+#8G)1-1/2"C (2) HYDRO TUBS = (3,840 VA) (� > r- (1) BOOSTER HEATER = (6,000 VA) J m LOAD REMOVED (CIRC L1 A-5): (9) 75W LIGHTS - (675 VA) —` o (2) RECEPTACLES = (360 VA) j FLAG NOTES THIS SHEET-. 0 LO z RECEPTACLES = 2.160 VA a a LOAD ADDED (CIRC L1A-5): u~i 1. REMOVE THE FUSED DISCONNECT SWITCH AND OUTLET SERVING THE HYDRO TUBS (2} RECEPTACLES = 360 VA (1) ICE MACHINE - 1,250 VA BEING REMOVED. REMOVE CONDUIT AND WIRE BACK TO PANEL. IF THE EXISTING CIRCUIT BREAKER IS NOT REUSED BY NEW WORK, LABEL CIRCUIT BREAKER SPARE. NEW TOTAL REMOVED: = 0 VA NEW TOTAL REMOVED: = (7,105 VA) Q PROVIDE A NEW PANEL INDEX. * NO LOAD ADDED * NO LOAD ADDED 0 2. RETAIN CIRCUIT CONTINUITY AFTER DEMOLITION OF EXISTING DEVICE. PROTECT THE CIRCUIT DEMO AND NEW AND EXTEND FOR NEW DEVICES AS NOTED. REFER TO NOTE 4 FOR MORE INFORMATION, ELECTRICAL PLANS a 3. RETAIN CIRCUIT CONTINUITY FOR LIGHTING AFTER DEMOLITION (H1A-9, 277V). PROTECT THE III CIRCUIT AND EXTEND FOR NEW DEVICES AS NOTED. REFER TO NOTE 5 FOR MORE INFORMATION. LUM I N AIRE SCHEDULE AND DETAILS 4. CONNECT THE NEW DUPLEX RECEPTACLE TO THE EXISTING BRANCH CIRCUIT (Ll A-5). TYPE TY.LACAT DESCRIPTION VOLT MOUNTING MANUFACTURER, CAT. NUMBER DATE 6 MAY 2005 5. CONNECT THE NEW LIGHTING FIXTURES TO THE EXISTING BRANCH CIRCUIT F1 2 F032/735 2'X4' 2-LAMP T8 FLUORESCENT LIGHTING FIXTURE 277 VERIFY FIXTURE SHALL MATCH HOSPITAL STANDARDS DRAWN BY SAR/THU FOR THIS ROOM (H1A-9. 277V). FIELD MEASURE AND VERIFY THAT THE NEW LOAD WITH ELECTRONIC BALLAST z PLUS THE EXISTING LOAD DOES NOT EXCEED 80% OF THE RAPED OCPD FOR CHK'D 6Y DPG ``' THE CIRCUIT. PROVIDE NEW SWITCHING AS NOTED. F2 3 F032/735 2'X4' 3-LAMP T8 FLUORESCENT LIGHTING FIXTURE 277 VERIFY FIXTURE SHALL MATCH HOSPITAL STANDARDS WITH ELECTRONIC BALLAST a 6, PROVIDE A NEW NURSE CALL CODE BLUE EMERGENCY STATION AND DOME LIGHT. SHEET FILE VVMCP?-E1.DWG NEW DEVICES SHALL BE COMPATIABLE WITH THE EXISTING NURSE CALL SYSTEM, EXTEND F3 2 F032/735 1X4' 2-LAMP T8 SURFACE-MOUNTED FLUORESCENT 277 SURFACE FIXTURE SHALL MATCH HOSPITAL STANDARDS COPYRIGHT 2005 BY DAMS PARTNERSHIP P.C., ARCHITECTS THE EXISTING DEVICE CIRCUITS AS REQUIRED, PROVIDE SYSTEM PROGRAMMING AS REQUIRED. WRAPAROUND LIGHT FIXTURE WITH ELECTRONIC BALLAST PROVIDE NEW 3/4"C STUB UP WITH PULL WIRE AND BUSHING FOR NEW CABLING. SHEET NUMBER: 7, NEW T-STAT: PROVIDE CONDUIT STUB UP WITH PULLWIRE AND BUSHING. El rn 0 MKK PROJECT# P19919 a m 0