HomeMy WebLinkAboutCalcs and data_1.pdf Fire Sprinkler Hydraulic Calculations & Equipment Submittals For 103 Rockledge Residence 103 Rockledge Rd. Vail, CO 81657 Edward Kolecke NICET Level III # 94588 Project Name : ROCKLEDGE RESIDENCE Drawing No. : 2181 Project Location: 103 ROCKLEDGE City: CALCULATION SUMMARYDesign AreasDesign AreaNameMin.DensityArea ofApplicationOccupancyCalculatedHeadsMin.PressureHoseStreamsTotal WaterPressure @SourceMargin ToSource(gpm/ft²)(ft²)#(psi)(gpm)(gpm)(psi)(psi)Min.Flow(gpm)Calc. Mode(Model) 1RES R78078.8Required25.80.1263029.128.2Demand (HW)Date 7/12/2016Page 1Copyright © 2002-2012 Tyco Fire Protection ProductsFile: C:\Users\Admin\appdata\local\temp\A-SPRINKCAD_CALC_1_1_5635.sv$ Design Remote Area Name Remote Area Location Occupancy Classification Density (gpm/ft²) Area of Application (ft²) Coverage per Sprinkler (ft²) Number of Calculated Sprinklers In-Rack Demand (gpm) Special Heads Hose Streams (gpm) Total Water Required (incl. Hose Streams) (gpm) Required Pressure at Source (psi) Type of System Volume - Entire System (gal) 1 REMOTE RES R 0.1 780 260 3 0 0 78.8 54.9 (available @ demand flow) Wet 32.4 gal Water Supply Information Date Location Source HYDRAULIC CALCULATIONS for NOT AVAIL TEST Project Name : ROCKLEDGE RESIDENCE Contract No. : 2181 Project Location: 103 ROCKLEDGE City: Date: 7/11/2016 Name of Contractor: ALL-STATE FP Address: 6045 E. 76TH AVE. #12 Phone Number: Name of Designer: MARION Authority Having Jurisdiction: City: DENVER, CO 80022 E-mail: Job Information Contractor Information Notes Date 7/12/2016 Page 2Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\Admin\appdata\local\temp\A-SPRINKCAD_CALC_1_1_5635.sv$ Job : ROCKLEDGE RESIDENCEDiagram for Design Area : 1 (Optimized Hydraulic Simplified)Node Labels:Pipe Labels:OffOffDate 7/12/2016Page 3Copyright © 2002-2012 Tyco Fire Protection ProductsFile: C:\Users\Admin\appdata\local\temp\A-SPRINKCAD_CALC_1_1_5635.sv$ Job : ROCKLEDGE RESIDENCE Hydraulic Analysis for : 1 Water Supply Parameters Calculation Info Calculation Mode Hydraulic ModelFluid Name Fluid Weight, (lb/ft³)Fluid Dynamic Viscosity, (lb·s/ft²) Demand Hazen-WilliamsWater @ 60F (15.6C) N/A for Hazen-Williams calculation.N/A for Hazen-Williams calculation. Supply 1 : TEST Flow (gpm)Pressure (psi) 0 55 1080 45 Node at Source Static Pressure (psi) Residual Pressure (psi) Flow (gpm) Available Pressure (psi) Total Demand (gpm) Required Pressure (psi) Supply Analysis TEST 55 45 1080 54.9 78.8 25.8 System Pump Flow (gpm)Pressure (psi) Rated Flow (gpm) Rated Pressure (psi) Parameters not defined not defined 0 110.5 80 110 120 90 Date 7/12/2016 Page 4Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\Admin\appdata\local\temp\A-SPRINKCAD_CALC_1_1_5635.sv$ Inside Hose Flow / Standpipe Demand (gpm) Outside Hose Flow (gpm) Additional Outside Hose Flow (gpm) Other (custom defined) Hose Flow (gpm) Total Hose Flow (gpm) Hoses Ovehead Sprinkler Flow (gpm) InRack Sprinkler Flow (gpm) Other (custom defined) Sprinkler Flow (gpm) Total Sprinkler Flow (gpm) 78.8 0 0 78.8 Required Margin of Safety (psi) TEST - Pressure (psi) TEST - Flow (gpm) Demand w/o System Pump(s) 0 54.9 78.8 135.5 psi @ 78.8 gpm Sprinklers Other Available @ 105-O (psi) Required @ 105-O (psi) Safety Margin @ 105-O (psi) 144.2 115.1 29.1 Pressure Summary @ Pump Discharge Date 7/12/2016 Page 5Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\Admin\appdata\local\temp\A-SPRINKCAD_CALC_1_1_5635.sv$ Job : ROCKLEDGE RESIDENCEHydraulic Analysis for : 1Flow, gpmPressure, psi200180160140120100806040200D1D2Adjusted Available Supply: 144.2 psi @ 78.8 gpmAdj. System DemandAdj. Available SupplySystem Pump050100150Date 7/12/2016Page 6Copyright © 2002-2012 Tyco Fire Protection ProductsFile: C:\Users\Admin\appdata\local\temp\A-SPRINKCAD_CALC_1_1_5635.sv$ Job : ROCKLEDGE RESIDENCE Hydraulic Analysis for : 1 Pressure (psi)Label Graph Labels Flow (gpm) ValuesDescription 0D1 9.2Elevation Pressure 78.8D2 115.1System Demand Open Heads Head Ref.DensityDensityK-Factor PressureFlowPressure (gpm/ft²)(gpm/ft²)(gpm/psi½)(psi)(gpm)(psi) Flow (gpm) Coverage (ft²) Required CalculatedHead Type A2 4.9 0.1 26 28.2 0.101 28.926.3260OverheadSprinkler A3 4.9 0.1 26 28.2 0.1 28.226260Overhead Sprinkler A4 4.9 0.1 26 28.2 0.102 29.126.4260OverheadSprinkler Date 7/12/2016 Page 7Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\Admin\appdata\local\temp\A-SPRINKCAD_CALC_1_1_5635.sv$ Job : ROCKLEDGE RESIDENCE Node Data Hydraulic Calculations / Fluid Delivery Time Analysis Node#Elev ft TypeHgroup K-Fact.Open/Closed gpm/psi½ DischargeOverdischarge gpm gpm CoverageDensity ft² gpm/ft² Tot. Pres.Elev. Pres. psi psi Req. Pres.Req. Discharge psi gpm A335.13 Overhead SprinklerHEAD 4.9Open 260 2600.1 28.2-15.3 28.226 A235.13 Overhead SprinklerHEAD 4.9Open 26.30.3 2600.101 28.9-15.3 28.226 A435.13 Overhead SprinklerHEAD 4.9Open 26.40.4 2600.102 29.1-15.3 28.226 105-I13.2 NodeNODE 5.4-5.8 106-O10.13 NodeNODE 7-4.5 106-I9.99 NodeNODE 10-4.4 107-O8.54 NodeNODE 10.8-3.8 107-I6.76 NodeNODE 17.3-3 TEST-0.25 SupplySUPPLY -78.8 25.80 00235.5 NodeNODE 30.9-15.5 00335.5 NodeNODE 31.8-15.5 08714 NodeNODE 97.8-6.2 10214 NodeNODE 114.7-6.2 105-O13.98 NodeNODE 115.1-6.2 Date 7/12/2016 Page 8Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\Admin\appdata\local\temp\A-SPRINKCAD_CALC_1_1_5635.sv$ Hydraulic CalculationsJob : ROCKLEDGE RESIDENCE PIPE INFORMATION Node 1 Node 2 Elev 1 Elev 2 (ft) K-Factor 1 K-Factor 2 (gpm/psi½) Flow added (q) Total flow (Q) (gpm) Nominal ID Actual ID (in) Fittings quantity x (name) = length (ft) L F T (ft) C Factor Pf per ft (psi) total (Pt) elev (Pe) frict (Pf) (psi) NOTES 1Path No: A3 002 35.13 35.5 4.9 26 26 1 0.995 1x(us.Tee-Br)=5.84 1x(us.90)=2.33 8.03 8.17 16.2 150 0.1804 28.2 -0.2 2.9 002 003 35.5 35.5 26.4 52.4 1.25 1.245 3.96 0 3.96 150 0.2221 30.9 0 0.9 003 087 35.5 14 26.3 78.8 1.25 1.245 3x(us.Tee-Br)=16.46 4x(us.90)=10.98 1x(us.45)=0.91 91.75 28.35 120.11 150 0.4716 31.8 9.3 56.6 087 102 14 14 0 78.8 1.5 1.481 1x(us.Tee-Br)=8.04 1x(us.90)=4.02 1x(us.45)=2.01 69.53 14.08 83.61 150 0.2025 97.8 0 16.9 102 105-O 14 13.98 0 78.8 2 1.959 7.37 0 7.37 150 0.0519 114.7 0.0 0.4 105-O 115.1 2Path No: A2 003 35.13 35.5 4.9 26.3 26.3 1 0.995 2x(us.Tee-Br)=11.67 5.09 11.67 16.76 150 0.1846 28.9 -0.2 3.1 003 31.8 3Path No: A4 002 35.13 35.5 4.9 26.4 26.4 1 0.995 1x(us.Tee-Br)=5.84 1x(us.90)=2.33 2.28 8.17 10.46 150 0.1861 29.1 -0.2 1.9 002 30.9 Date 7/12/2016 Page 9Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\Admin\appdata\local\temp\A-SPRINKCAD_CALC_1_1_5635.sv$ Hydraulic CalculationsJob : ROCKLEDGE RESIDENCE PIPE INFORMATION Node 1 Node 2 Elev 1 Elev 2 (ft) K-Factor 1 K-Factor 2 (gpm/psi½) Flow added (q) Total flow (Q) (gpm) Nominal ID Actual ID (in) Fittings quantity x (name) = length (ft) L F T (ft) C Factor Pf per ft (psi) total (Pt) elev (Pe) frict (Pf) (psi) NOTES Pump to Supply at Demand Flow 105-O 105-I 13.98 13.2 0 78.8 2 0 0.77 0 0.77 0 142.2049 144.2 0.3 -110 Pump *** 105-I 106-O 13.2 10.13 0 78.8 2 1.959 1x(coupling)=1.16 3.75 1.16 4.91 150 0.0519 34.5 1.3 0.3 106-O 106-I 10.13 9.99 0 78.8 2 0 0.14 0 0.14 0 21.1765 36.1 0.1 3 Flow Switch *** 106-I 107-O 9.99 8.54 0 78.8 2 1.959 1x(coupling)=1.16 1.52 1.16 2.69 150 0.0519 39.2 0.6 0.1 107-O 107-I 8.54 6.76 0 78.8 2 0 1.78 0 1.78 0 3.2086 39.9 0.8 5.7 Ames2000B *** 107-I TEST 6.76 -0.25 0 78.8 2 2.003 1x(BM.90)=10 107.01 10 117.01 150 0.0465 46.4 3 5.4 TEST 54.9 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. *** Device pressure loss (gain in the case of pumps) is calculated from the device’s curve. If the device curve is printed withthis report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is basedsolely on the curve data. * Maximum Velocity of 20.76 ft/s occurs in the following pipe(s): (087-003) Date 7/12/2016 Page 10Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\Admin\appdata\local\temp\A-SPRINKCAD_CALC_1_1_5635.sv$ Device GraphsJob : ROCKLEDGE RESIDENCE Pressure vs. Flow Function Design Area: 1; Supply Ref.: TEST; Supply Name:TEST Flow, gpm0200300400500600700800 90010001080Pressure, psi60 55 50 45 40 35 30 25 20 15 10 5 0 Pressure Loss Function Design Area: 1; BFP Ref.: 501 (Ames2000B, Size = 2); Inlet Node: 107-I; Outlet Node: 107-O Flow, gpm012.5255075100125150175200Pressure, psi7.69 6.69 5.69 4.69 3.69 2.69 1.69 0.69 5.7 psi @ 78.8 gpm Date 7/12/2016 Page 11Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\Admin\appdata\local\temp\A-SPRINKCAD_CALC_1_1_5635.sv$ Device GraphsJob : ROCKLEDGE RESIDENCE Pressure Boost Function Design Area: 1; Pump Ref.: 503 (Pump, Size = 2); Inlet Node: 105-I; Outlet Node: 105-O Flow, gpm080 120Pressure, psi111.55 101.55 91.55 81.55 71.55 61.55 51.55 41.55 31.55 21.55 11.55 1.55 110 psi @ 78.8 gpm Pressure Loss Function Design Area: 1; Valve Ref.: 502 (Flow Switch, Size = 2); Inlet Node: 106-I; Outlet Node: 106-O Flow, gpm0 75150Pressure, psi2.8 2.3 1.8 1.3 0.8 0.3 3 psi @ 78.8 gpm Date 7/12/2016 Page 12Copyright © 2002-2012 Tyco Fire Protection Products File: C:\Users\Admin\appdata\local\temp\A-SPRINKCAD_CALC_1_1_5635.sv$ Table of Contents 1. Sprinkler Heads Globe Model 4906 Concealed Pendent Globe Model GL Uprights, Sidewalls Globe Model 5606 Concealed pendent Globe Model GL Dry Sidewall 2. Valves Wilkins Model 950XL Double Check Backflow Nibco Check Valve Croker Fire Department Connection AGF Test-n-Drain Valve w/ Pressure Relief 3. Pipe and Fittings Bull Moose Tube Schedule Eddy-Thread Youngstown Tube Schedule EZ-Thread CDA Copper Pipe Type M Smith-Cooper Ductile Iron Threaded Fittings EPC Copper Fittings 4. Electrical System Sensor Water Flow Switch Potter Ball Valve Supervisory Switch System Sensor Exterior Horn/Strobe Talco LSF-1000CIG5 Res. Fire Pump 5. Hangers Tolco Band Hanger Tolco All-Thread Rod Tolco Top Beam Clamp Sammy Wood Sidewinder 1$*,+&,0+6,'1$76(9,5'.5$35,$;$) $9(5/*1,7(//8%5(%0(73(6 7(+,+&1  5 /$,71(',6( $&,7$0278 6 65(/.1,53 0 /('2 /* 2 (1 ,+&1 $(/%$768-' )7$/3 (7$/&'(/$(&12 3 71('1( ''1$12,73,5&6(2 12,7$5(3 /$,71(',6(5 (7$/37$/) 71('1(3'(/$(&12& 7 /$&,1+&('$7$ VQRLWDFLILFHS6GQDVODYRUSS$URIHGLVHVUHYHUHH6 &ƒ )ƒJQLWD5HUXWDUHSPH7 VUD% LVSJQLWD5HUXVVHU3JQLNUR:UHWD: VUD% LVSRW\OODFLWDWVRUG\KGHWVHW\URWFD) &ƒ )ƒ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ƒ&ƒ'(5)ƒ&ƒ ;$) PRFUHONQLUSVHEROJZZZ $68'(71,53 1$*,+&,0+6,'1$76(9,5'.5$35,$   5(%0(73(6 9(5/*1,7(//8% 6 '1$612,7$&,),&(3 $6/$92533 5 /$,71(',6( $&,7$0278 6 65(/.1,53 0 /('2 2/*(1 ,+&1 $(/%$768-' )7$/3(7$/&'(/$(&12 3 71('1( (721 (7$0,;2533$(5$612,65(912&&,57(0 *(%2/Š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ƒ )ƒ +7,:5(/.1,536 (7$/3 &ƒ )ƒ VX/8F/$1,021 527&$). HPRUK&WKJLU% GHWQLD3HWLK:  VVDU%WKJLU%  HPRUK&QLWD6 VHKVLQL)GHWQLD3UHKW2 731 PF /* FLUWHP ;; /('20 )2$(5$080,;$0 (*$5(92&  (*5$+&6,'5(7$:080,1,0 5(/.1,5365(3'('((16(5866(53 [ ,6303* [ ,6303* [ ,6303* [ ,6303*  [ ,6303* /* 71('1(3'(/$(&12&(7$/37$/)(/%$768-'$+&1,(12  ;$01,0 (7$/35(92&*1,/,(& //(+67523386 38& 527&(/)('1,3325' [5(&8'(5 $,' 1,0$,' *1,/,(&1,(/2+ (7$/35(92& (=,6 )ƒ(7,+: 75$3 )ƒ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ƒ )ƒ &ƒ )ƒVJQLWD5HUXWDUHSPH7 &ƒ )ƒ &ƒ )ƒ &ƒ )ƒ VUD% LVSJQLWD5HUXVVHU3JQLNUR:UHWD: VUD% LVSRW\OODFLWDWVRUG\KGHWVHW\URWFD) &ƒ )ƒVLJQLWDUEOXEVVDOJHUXWDUHSPHWZROPXPL[D0 VVDUEZHUF6VVDUEURWFHOIH'H]QRUEHPDU) OHHWVVVHOQLDWVHUL:WQHPHJGR/ QROIHWODH6\ROODOHNFLQJQLUS6UHSSRFWDHVEOX% H]LVPPQRLWXORVGHVDEORKRFODKWLZVVDOJEOX% 7 /$&,1+&('$7$ 12,7$&,),66$/&52/2&%/8% <5$1,'52)ƒ)ƒ&ƒ&ƒ'(5(*1$52)ƒ&ƒ (7$,'(05(71,)ƒ)ƒ&ƒ&ƒ1((5*:2//(<)ƒ&ƒ +*,+)ƒ&ƒ(8/%)ƒ&ƒ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Š3 7&8'25 :<71$55$ HO\W6UHEPX1OHGR0\WLWQDX4 HUXWDUHSPH7VH]L6GDHUK7HFLILU2 GHULVHGVHKVLQL)   13VHKFQHU:\WLWQDX4 2/ 13 527&$)./$1,021(=,6'$(5+7+7*1(/6(+6,1,) FLUWHP  FLUWHP  FLUWHP  FLUWHP  FLUWHP  731 731 731 731 731 PF  PF  PF  PF  PF  H]QRU%\URWFD) HPRUK& UHWVH\OR3HWLK: UHWVH\OR3NFDO% 671(08&2''(7$/(55(+72<1$'1$$3)1)2671(0(5,84(5(+75(36$'(7,0,/(%//$+665(/.1,536 *1,/,(&(+7:2/(%27'(92533$0)*1,/,(&(+7:2/(%27527&(/)('52)'(76,/VX/8F//$:(',6/$712=,52+† 671(08&2''(7$/(55(+72<1$'1$6%27(&1$'52&&$1,//$761,͞ ‚*1,&$361,0 52)'(76,/VX/8F//$:(',6/$&,75(971('1(3 *1,&$361,0 52)'(76,/VX/8F//$:(',6/$&,75(97+*,538‚ '5$=$+<5$1,'52+2 '5$=$+7+*,/+/ 731 (/<76 1,6 /('20 . 527&$)'5$=$+)ƒ &ƒ )ƒ &ƒ )ƒ &ƒ )ƒ &ƒ )ƒ &ƒVX/8F0)&3/(&%2'&<1 ($(0 7+*,538 /$12,71(912& (/<76'/2 /$712=,52+ //$:(',6 /$&,75(9 //$:(',6 ‚ 71('1(3 /* /*                      /* /* /* /* /* /* /* /* /* /* /* /* †/* †/* †/* ͞/* †/* +2+/ +2+/ ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; +/ +/ +2+/ +2+/ +2+/ +/ +/ +2+/ +2+/ +2+/ +/ +/ +/ +/ +2+/ +2+/ +2+/ ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ;   ;  ;   ;  ;   ;  ;     ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ;  ;   ;  ;   ; ; ; ; ;   ;  ; ; ; ; ; ; ; ; ;     ; ; ; ;    ;            ;     ;  4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 FAX 989-846-9231989-846-4583 A-58JULY 2010 BULLETIN GL5641, REV. #14 SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING The Globe Quick Response GL Series Dry Type Horizontal Sidewall Sprinkler is designed for use in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary horizontal pipe nipples. The Globe Quick Response GL Series Dry Type Horizontal Sidewall Sprinkler utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move, allowing the spring assembly to pivot alongside the inner tube. At this time, water flows through the sprinkler and is distributed by the deflector, in an approved discharge pattern. It can be installed wherever standard spray sprinklers are specified but offers the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern. DESCRIPTION AND OPERATION TECHNICAL DATA CLASSIFICATION AVAILABLE SPRINKLER TEMPERATURES BULB COLOR N.F.P.A. MAXIMUM CEILING TEMPERATURE ORDINARY 135°F/155°F 57°C/68°C ORANGE/RED 100°F 38°C INTERMEDIATE 175°F/200°F 79°C/93°C YELLOW/GREEN 150°F 66°C HIGH 286°F 141°C BLUE 225°F 107°C See reverse side for Approvals and Specifications. Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C). Water Working Pressure Rating - 175 psi (12 Bars). Factory tested hydrostatically to 500 psi (34 Bars). Maximum low temperature glass bulb rating is -67°F (-55°C). Frame - bronze Deflector - brass Screw - brass Bulb seat - brass Spring - teflon coated nickel alloy Retainer - brass Pin - stainless steel Torsion spring - stainless steel Bulb - glass with alcohol based solution, 3mm Orifice insert - brass 3/4" NPT or 1" NPT Outer tube - galvanized steel pipe Inner tube - stainless steel QUICK RESPONSE DRY NON-ADJUSTABLE HORIZONTAL SIDEWALL QUICK RESPONSE DRY SLEEVE & SKIRT HORIZONTAL SIDEWALL QUICK RESPONSE DRY RECESSED HORIZONTAL SIDEWALL QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES DRY TYPE HORIZONTAL SIDEWALL RECESSED HORIZONTAL SIDEWALL FAX 989-846-9231 www.globesprinkler.com PRINTED U.S.A. 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 1-800-248-0278 JULY 2010 BULLETIN GL5641, REV. #14 QUICK R ESPONSE AUTOMATIC SPRINKLERS GL SERIES DRY TYPE NON-ADJUSTABLE HORIZONTAL SIDEWALL RECESSED HORIZONTAL SIDEWALL APPROVALS CROSS SECTIONS SLEEVE & SKIRT HORIZONTAL SIDEWALL EXTENDED HORIZONTAL SIDEWALL Quantity Model Number Style Orifice Temperature Finishes desired Quantity - Wrenches - P/N 333010 Quantity - Recessed Wrenches - P/N 337014 Quantity - Protective Caps - P/N 327109-CAP (Friction Fit Recessed) Escutcheons desired "A" Dimension - Distance from face of fitting to the finished ceiling regardless of escutcheon used. ORDERING INFORMATION SPECIFY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). GLOBE® PRODUCT W ARRANTY Globe GL Series Dry Horizontal Sidewall sprinklers should be installed in accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler head wrench may be used with extreme care for lengths up to approximately 18". Excessive force may distort the frame thus destroying the unit. When installed in a wet system extending into a freezing area see chart on Dry Caution Sheet for minimum exposed barrel length to prevent ice plugs. Please refer to our Dry Caution sheet for further important installation data. IMPORTANT INSTALLATION DATA SPECIFICATIONS THREAD SIZE LENGTH FINISHES FM Variable to 36" NOMINAL "K' FACTOR Factory Bronze Satin Chrome1 Bright Chrome White Polyester Black Polyester Lead Coated2 5.6 (80 metric) 8.1 (116 metric) 3/4" or 1" NPT 1" NPT cULus Variable to 48" NOTE: Metric Conversions are approximate. cULus listed corrosion resistant: Polyester must be specified on order. 1Finishes available on special order. 2Lead Coated is UL approved only. GL5641 5.6 a 1" NPTXXXXXXX GL5642 5.6 a 3/4" NPTXXXXX- X GL8141 8.1b 1" NPTXXXXX- X GL5641 5.6 a 1" NPTXXXXXXX GL5642 5.6 a 3/4" NPTXXXXX- X GL8141 8.1b 1" NPTXXXXX- X * FM135°F 57°C 155°F 68°C 175°F 79°C 200°F 93°C HORIZONTAL SIDEWALL RECESSED HORIZONTAL SIDEWALL 286°F 141°C cULusSTYLE SIN CODE K FACTOR THREAD SIZE NOTE: aListed for light hazard only with deflector from 4"-12" below the ceiling. bListed for light and ordinary hazard with deflector from 4"-12" below the ceiling. *Recessed Horizontal Sidewall - FM Approved 155°F and 200°F only. *Horizontal Sidewall - FM Approved 155°F, 200°F, and 286°F only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ô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ƒ )ƒUHONQLUS6 &ƒ )ƒ HWDO3UHYR& &ƒ )ƒUHONQLUS6 &ƒ )ƒ HWDO3UHYR& &ƒ )ƒUHONQLUS6 &ƒ )ƒ HWDO3UHYR& &ƒ )ƒUHONQLUS6 &ƒ )ƒ HWDO3UHYR& &ƒ )ƒUHONQLUS6 &ƒ )ƒ VUD% LVSJQLWD5HUXVVHU3JQLNUR:UHWD: VUD% LVSRW\OODFLWDWVRUG\KGHWVHW\URWFD) &ƒ )ƒVLJQLWDUEOXEVVDOJHUXWDUHSPHWZROPXPL[D0 VVDUEZHUF6VVDUEURWFHOIH'H]QRUEHPDU) QROIHWODH6\ROODOHNFLQJQLUS6VVDUEWDHVEOX% H]LVPPQRLWXORVGHVDEORKRFODKWLZVVDOJEOX% OHHWVVVHOQLDWVQL3SRU' VVDUEHWDO3UHYR& OHHWVGHWDOS\OEPHVV$QRHKFWXFV(UHSS8 UHONQLUSVVLKWOODWVQLRWGHVXHEWVXP13KFQHUZV HERO*(721 HWDOSUHWHPDLG 7 (+,+&1 4 .&,8 5 (61236( $&,7$0278 6 65(/.1,53 0 /('2 /* 2 (1 ,+&1 $(/%$768-' &'(/$(&12 3 71('1( 12,7$&,),66$/&(/%$/,$9$ 6(587$5(30(75(/.1,536 %/8% 52/2& *1,/,(&080,;$0$3)1 (587$5(30(7 <5$1,'52)ƒ)ƒ&ƒ&ƒ'(5(*1$52)ƒ&ƒ (7$,'(05(71,)ƒ)ƒ&ƒ&ƒ1((5*:2//(<)ƒ&ƒ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Š3 7&8'25 :<71$55$ &6625 6 612,7&( (61236(5'5$'1$766$'(92533$0) 6/$92533$0)21 (=,6'$(5+7+7*1(/6(+6,1,)527&$)./$1,021 FLUWHP HPRUK&WKJLU% GHWQLD3HWLK: VVDU%WKJLU% HPRUK&QLWD6  VHKVLQL)GHWQLD3UHKW2  731 PF  (721 (7$0,;2533$(5$612,65(912&&,57(05(+726(7$/3'(71,$352)5('52/$,&(3612(/%$/,$9$6(+6,1,) 612,7$&,),&(36*1,5('5252)(%2/*7&$712&(7,+:1$+7 5(92&/$12,732 (=,6(7$/3 )ƒ(7,+: 75$3 )ƒ(7,+: 75$3 )ƒ(025+& 75$3 )ƒ(025+& 75$3   $,'$,' ;$01,0  1,0$,'*1,/,(&1,(/2+ (7$/35(92&*1,/,(& //(+67523386 527&(/)('1,3325' 38& [5(&8'(5 [5(&8'(5 38& 527&(/)('1,3325' //(+67523386 (7$/35(92&*1,/,(& 1,0$,'*1,/,(&1,(/2+ ;$01,0  (/<76 1,6 /('20 . 527&$)  &ƒ )ƒ HWDOSKWLZ &ƒ )ƒ  &ƒ )ƒ HWDOSKWLZ &ƒ )ƒ  &ƒ )ƒ HWDOSKWLZ &ƒ )ƒ  &ƒ )ƒ HWDOSKWLZ &ƒ )ƒ  &ƒ )ƒ HWDOSKWLZ &ƒ )ƒ VX/8F0) %2'&<1 $(0 ( HOEDWVXMG$ GHODHFQR& WQHGQH3 /*; ;;;;;;; a company ® ® DOCUMENT #: REVISION:BF-950XL 10/10 SPECIFICATION SUBMITTAL SHEET Page 1 of 2 Model 950XL Double Check Valve Assembly WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766In Canada: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) • Website: http://www.zurn.com FEATURES Sizes: 3/4"  1"  1-1/4"  1-1/2"  2" Maximum working water pressure 175 PSI Maximum working water temperature 180°F Hydrostatic test pressure 350 PSI End connections Threaded ANSI B1.20.1 OPTIONS (Suffixes can be combined)  - with full port QT ball valves (standard)  L - less ball valves  U - with union ball valves  S - with bronze "Y" type strainer  TCU - with test cocks "vertical" up  V - with union swivel elbows (3/4” & 1”)  OSY - with OS & Y gate valves  FDC - with fire hydrant connection (2” only)  FT - with integral male 45° flare SAE test fitting ACCESSORIES  Repair kit (rubber only)  Thermal expansion tank (Model WXTP)  QT-SET Quick Test Fitting Set  Test Cock Lock (Model TCL24) DIMENSIONS & WEIGHTS (do not include pkg.) C E F B G D A APPLICATION Designed for installation on potable water lines to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Assembly shall provide protection where a potential health hazard does not exist. STANDARDS COMPLIANCE (All sizes approved horizontal. Vertical approvals as listed below.)  ASSE® Listed 1015 ( vertical 3/4”, 1 1/4”, 1 1/2” & 2”)  IAPMO® Listed (vertical 1 1/4”-2”)  CSA® Listed ( vertical 3/4”, 1 1/4”, 1 1/2” & 2”)  AWWA Compliant C510 (vertical 3/4”)  UL® Classified (less shut-off valves only)  C-UL® Classified (less shut-off valves only)  Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (vertical 3/4”)  City of Los Angeles Approved (vertical 1-1/4"-2")  NYC MEA 426-89-M VOL 3 MATERIALS Main valve body Cast Bronze ASTM B 584 Access covers Cast Bronze ASTM B 584 Internals Stainless Steel, 300 Series Elastomers Silicone (FDA approved) Buna Nitrile (FDA approved) Polymers Noryl™, NSF Listed Springs Stainless steel, 300 series MODEL SIZE DIMENSIONS (approximate)WEIGHT A A UNION BALL VALVES B LESS BALLVALVES C D E F G LESS BALL VALVES WITH BALL VALVES in.mm in.mm in.mm in.mm in.mm in.mm in.mm in.mm in.mm lbs kg lbs.kg3/4 20 11 1/4 286 12 1/2 318 7 178 1 1/2 38 3 76 3 1/2 89 3 76 15 381 5 2.3 7 3.212512 1/4 311 13 7/8 353 7 178 1 1/2 38 3 76 3 1/2 89 3 76 17 3/4 451 8 3.6 12 5.4 1 1/4 32 15 1/2 419 18 1/2 470 10 9/16 268 2 51 3 1/2 89 4 1/2 114 4 1/2 114 21 1/2 546 16 7.3 22 10 1 1/2 40 17 1/8 435 19 1/8 486 10 9/16 268 2 51 3 1/2 89 4 1/2 114 4 1/2 114 22 3/4 578 16 7.3 22 10 2 50 18 1/4 460 20 508 10 9/16 268 2 51 3 1/2 89 4 1/2 114 4 1/2 114 25 1/8 638 16 7.3 28 12.7 Page 2 of 2 WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) • Website: http://www.zurn.com FLOW CHARACTERISTICS TYPICAL INSTALLATION Local codes shall govern installation requirements. To be installed in accordance with the manufacturer’s instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12” (305mm) and a maximum of 30” (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. SPECIFICATIONS The Double Check Valve Backflow Preventer shall be ASSE® Listed 1015 approved, and supplied with full port ball valves. The main body and access covers shall be bronze (ASTM B 584), the seat rings and all internal polymers shall be NSF® Listed Noryl™ and the seat disc elastomers shall be silicone. The first and second checks shall be acces- sible for maintenance without removing the device from the line. The Double Check Valve Backflow Preventer shall be a WILKINS Model 950XL. OUTDOOR INSTALLATION INDOOR INSTALLATION Capacity thru Schedule 40 Pipe Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 1/8"1 1 2 3 1/4"2 2 3 5 3/8"3 4 6 9 1/2 5 7 9 14 3/4"8 12 17 25 1"13 20 27 40 1 1/4"23 35 47 70 1 1/2"32 48 63 95 2"52 78 105 167 DIRECTION OF FLOW 12" MIN30" MAX DIRECTION OF FLOW PROTECTIVEENCLOSURE 12" MIN. 30" MAX. 0 20 60 800 5 10 15 0 50 100150 200 250 5 10 15 40 0 Rated Flow (Established by approval agencies) FLOW RATES (GPM)PRESSURE LOSS (PSIG) 69 PRESSURE LOSS (kpa) FLOW RATES (l/s) MODEL 950XL 3/4", 1", 1 1/4", 1 1/2" & 2" (STANDARD & METRIC) 35 3/4" (20mm)1" (25mm)1 1/4" (32mm)1 1/2" (40mm) 2" (50mm) 10315.812.69.56.33.25.03.82.521.26 AHEAD OF THE FLOW ™ wwwwww..nniibbccoo..ccoomm 18 NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 0066//2211//0055 NIBCO check valves may be installed in both horizontal and vertical lines with upward flow or in any intermediate position. They will operate satisfactorily in a declining plane (no more than 15º). Warning – Do Not Use For Reciprocating Air Compressor Service. Class 125 Bronze Check Valves Horizontal Swing • Regrinding Type • Y-Pattern • Renewable Seat and Disc 125 PSI/8.6 Bar Saturated Steam to 353º F/178º C 200 PSI/13.8 Bar Non-Shock Cold Working Pressure CONFORMS TO MSS SP-80 T-413 Threaded T-413-Y NPT x NPT DIMENSIONS—WEIGHTS—QUANTITIES Dimensions Size A B Master In. mm. In. mm. In. mm. Lbs. Kg. Ctn. Qty. ¹⁄₄8 2.13 54 1.63 41 0.50 0.23 50 ³⁄₈10 2.13 54 1.63 41 0.47 0.22 50 ¹⁄₂15 2.44 62 1.69 43 0.55 0.25 50 ³⁄₄20 2.94 75 1.88 48 0.90 0.41 50 1 25 3.56 90 2.31 59 1.46 0.66 30 1¹⁄₄32 4.19 106 2.69 68 2.17 0.99 20 1¹⁄₂40 4.50 114 2.94 75 2.95 1.34 10 2 50 5.25 133 3.94 100 4.79 2.17 10 2¹⁄₂* 65 8.00 203 5.06 129 11.48 5.21 5 3* 80 9.25 235 6.25 159 17.53 7.96 4 Ordering: T-413 normally furnished with Bronze Disc (T-413-B). Available with PTFE Steam Disc (T-413-Y) or CWP Disc (T-413-W) or 300º F 67 PSI steam Viton Disc (T-413-V). *– Class 150 (433) furnished for these sizes. MATERIAL LIST PART SPECIFICATION 1. Bonnet Bronze ASTM B 62 2. Body Bronze ASTM B 62 3. Hinge Pin Bronze ASTM B 140 Alloy C31400 or B 134 Alloy C23000 4. Disc Hanger Bronze ASTM B 62 or 304 Stainless Steel ¹⁄₄" thru ³⁄₄" sizes 5. Hanger Nut Bronze ASTM B 16 6. Disc Holder Bronze ASTM B 62 7. Seat Disc Water, Oil or Gas (Buna-N) (W) Steam (PTFE) (Y) Bronze ASTM B 62 (B) Viton (V) 8. Seat Disc Nut Bronze ASTM B 16 or B 62 9. Hinge Pin Plug Bronze ASTMB 140 Alloy C32000 (not shown) *10. Seat Disc Washer ASTM B 98 Alloy C65500 or ASTM B 103 (not shown) *Sizes ³⁄₄", 1", 1¹⁄₄", and 1¹⁄₂" only. T-413-B NPT x NPT Dezincification Resistant FIRE DEPT. INLET CONN. FLUSH TYPE6341-6345 SERIES SINGLE INLET An inlet connection with 250 G.P.M. minimum inlet capacity to supplement the fire protection water supply. Provides unobstructed water supply. Flush round design enhances appearance and provides unobstructed passage. STANDARD EQUIPMENT:Cast Brass round plate with double female adapter; plug and chain; branding as selected. SPECIFY THREAD AND BRANDING. BRANDING: "Standpipe", "Auto Spkr." FINISH: Cast Brass OPTIONAL FINISH:PB-Polished Brass PC-Polished Chrome RESIDENTIAL FIRE DEPT. CONNECTION An inlet connection to supplement the water supply to a residential sprinkler system. STANDARD EQUIPMENT: 1 1/2" cast brass round plate assembly with integral pin lug swivel inlet. Hose thread inlet swivel, 1 1/2" NPT female outlet on back of plate. Cast brass plug and brass chain. Overall outside Diameter 4 3/8". SPECIFY THREAD AND BRANDING. U/L LISTED. BRANDING: "Auto Spkr." FINISH: Cast Brass OPTIONAL FINISH:PB-Polished Brass PC-Polished Chrome Figure No. 6341 Figure No. 6342 Figure No. 6345 Page 6-12 Round Plate Figure No. Size 6341 2 1/2 X 2 1/2 6342 3 X 2 1/2 6343 3 X 3 ___________________________________________________ Model 1011A TESTa n DRaIn® ¾" 1" 1¼" 1½" 2" Sectional Floor Control Test and Drain Valve for Systems Requiring Pressure Relief Valve Reliability, Versatility, Code Compatibility • The AGF Manufacturing Inc. Model 1011A TESTa n DRaIn® matches all the features and benefits of our Model 1000 by providing both the test function and the express drain function in a multistory installation for a wet fire sprinkler system, with the added feature of an integral Model 7000 Pressure Relief Valve with drainage piping. • The Model 1011A complies with the requirements of NFPA-13 that stipulate a pressure relief valve be installed on all gridded systems and downstream of all pressure reducing valves (see reverse). • The Model 1011A TESTa n DRaIn® is a compact single handle ball valve which includes a tamper resistant test orifice and integral tamper resistant sight glasses, and is 300 PSI rated. • Available in a full range of sizes from ¾" to 2" NPT and BSPT, with all specifiable orifice sizes ³⁄8" (2.8K), 7⁄16" (4.2K), ½" (5.6K), 17⁄32" (8.0K), 5⁄8" (11.2K, ELO), ¾" (14.0K, ESFR), and K25 as required by NFPA 13, 2007 Edi- tion (see reverse). • The included UL/FM Model 7000 Pressure Relief Valve features a flushing handle and is factory rated for 175 PSI. Other pressure settings are available and may be substituted. • Designed to relieve excess system pressure caused by surges or temperature changes as well as solve the dif- ficult problem of providing the relief valve with a convenient drainage-piping outlet. • Shipped with relief valve and bypass drain ports plugged to expedite pressure testing the system. • A locking kit is available and can be ordered with the valve to provide vandal resistance or prevent uninten- tional alarm activation. • Repair kits including (1) adapter gasket, (1) ball, (2) valve seats, (1) stem packing, and (1) stem washer are avail- able for all TESTa n DRaIn® valves. Valve and orifice size must be specified when ordering. Note: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to oPeN in a range of pressure between 90% and 105% of their rating. the valves are required to CLoSe at a pressure above 80% of that rating. the relief valve should be installed where it is easily accessible for main- tenance. Care should be taken that the relief valve CANNot be isolated from the system when the system is operational. A relief valve should NeVeR have a shutoff valve or a plug downstream of its outlet. CS1011A 10/09TESTANDRAIN is a registered trademark of AGF Manufacturing Inc. Model 1011A TESTa n DRaIn® Di m e n s i o n s Orifice Size Available: 3⁄8", 7⁄16", 1⁄2", 17⁄32", ELO (5⁄8")*, ESFR (3⁄4")*, & K25** SIZE A B C D E F G H ¾"79⁄16"(191 mm)11⁄2"(37.5 mm)23⁄16"(57 mm)35⁄8"(93 mm)33⁄8"(86 mm)113⁄16"(46 mm)49⁄16"(117 mm)63⁄8"(162.5 mm) 1"79⁄16" (191 mm) 11⁄2" (37.5 mm) 23⁄16" (57 mm) 35⁄8" (93 mm) 33⁄8" (86 mm) 113⁄16" (46 mm) 49⁄16" (117 mm) 63⁄8" (162.5 mm) 11⁄4"715⁄16" (201 mm) 111⁄16" (43 mm) 29⁄16" (65 mm) 41⁄4" (108 mm) 35⁄8" (91 mm) 115⁄16" (51 mm) 59⁄16" (141 mm) 51⁄2" (192 mm) 1½"815⁄16" (227 mm) 113⁄16" (45 mm) 31⁄4" (81.5 mm) 51⁄16" (127 mm) 37⁄8" (99 mm) 25⁄8" (67 mm) 81⁄4" (207 mm) 107⁄8" (274 mm) 2"815⁄16" (227 mm) 113⁄16" (45 mm) 31⁄4" (81.5 mm) 51⁄16" (127 mm) 37⁄8" (99 mm) 25⁄8" (67 mm) 81⁄4" (207 mm) 107⁄8" (274 mm) * Available on 11⁄4" to 2" size units only ** Available on 11⁄2" and 2" size units only TO DRAIN TO DRAIN H F G E A A INLET D B C Ap p r o v A l s UL and ULC Listed: (EX4019 & EX4533) FM Approved NYC-BSA No. 720-87-SM Job Name:__________________________________ Architect: ___________________________________ Engineer: ___________________________________ Contractor: _________________________________ USA Patent # 4741361 and Other Patents Pending mA t e r i A l s Handle: Steel Stem: Rod Brass Ball: C.P. Brass Body: Bronze Valve Seat: Impregnated Teflon® Indicator Plate: Steel Relief Valve: Bronze Bypass Fittings: Brass Bypass Tubing: Nylobraid mo D e l 1011A - Fr o n t vi e w mo D e l 1011A - pl A n vi e w AGF Manufacturing Inc. 100 Quaker Lane, Malvern, PA 19355 Phone: 610-240-4900 Fax: 610-240-4906 www.testandrain.com Model 1011A 300 PSI Bronze Ball Valve, Model 7000 Pressure Relief Valve Factory Rated at 175 PSI with other settings available th e mo D e l 1011A p r o v i D e s A l l o F t h e F o l l o w i n g … From the 2007 Edition of NFPA 13 Chapter 8.16.2.4.1* Provisions shall be made to properly drain all parts of the system. Chapter 8.16.2.4.2 Drain connections, interior sectional or floor control valve(s) – shall be provided with a drain connection having a minimum size as shown in Table 8.16.2.4.2. Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drain. Chapter A.8.17.4.2 (Wet Pipe System) test connection is permitted to terminate into a drain capable of accepting full flow… using an approved sight test connection containing a smooth bore corrosion-resistant orifice giving a flow equivalent to one sprinkler… Chapter 8.17.4.2.2 The test connection valve shall be readily accessible. Chapter 8.17.4.2.4 shall be permitted to be installed in any location… downstream of the waterflow alarm. Chapter 8.17.4.3.1 (Dry Pipe System) a trip test connection not less than 1" in diameter, terminating in a smooth bore corrosion-resistant orifice, to provide a flow equivalent to one sprinkler… Chapter 8.17.4.3.2 The trip test connection… with a shutoff valve and plug not less than 1", at least one of which shall be brass. Chapter 7.1.2 - a gridded wet pipe system shall be provided with a relief valve set to operate at 175 PSI or 10 PSI in excess of the maximum system pressure, whichever is greater. Chapter 8.16.1.2.3* A relief valve of not less than ½" in size shall be provided on the discharge side of the pressure-reducing valve set to operate at a pressure not exceeding 175 PSI. Chapter A.8.16.1.2.3 - consideration should be given to piping the discharge from the (pressure relief) valve & 8.16.2.4.3 Eddythread 40 A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1.0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: • Has a Corrosion Resistance Ratio of 1.0 • Has a Pressure Rating of 300 psi • Is Lighter Weight Than Schedule 40 • Is Approved by Factory Mutual and Listed by Underwriters Laboratories • Is Produced in Accordance to ASTM A-135 and A-795 • Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves • Is Produced From Steel With Excellent Properties of Strength and Threadability • Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* • Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS NOMINAL PIPE SIZE (in) WEIGHT (lbs/ft) I.D. (in) BUNDLE SIZE 1 1.461 1.083 70 1 1/4 2.070 1.418 51 1 1/2 2.547 1.654 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS NOMINAL PIPE SIZE (in) SCHEDULE 40 EDDYTHREAD 40 1 1.00 1.00 1 1/4 1.00 1.00 1 1/2 1.00 1.00 2 1.00 1.00 * Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems A company 1819 Clarkson Road Chesterfield, MO 63017 (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com e-mail:sales@bullmoosetube.com For additional information, contact your salesperson today at (800) 325-4467 or (636) 537-2600 in the USA, or from Canada call (800) 882-4666 All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 Mission Who We Are Press Room CDA Offices Membership Member Login Architecture Automotive Electrical Building Wire Energy Efficiency Power Quality Tube, Pipe & Fittings Fuel Gas Industrial Marine Machined Products Telecommunications Copper Compounds Antimicrobial Copper Alloy Surfaces Find Suppliers Of Copper Copper Data Center Standards & Properties Applications Directory Market Data Publications List Copper Topics Home > Applications > Tube, Pipe & Fittings > Technical References > Copper Tube Handbook > Table of Contents > Index of Tables > Table 2c - Type M Tube Copper Tube Handbook: Table 2c - Type M Tube Dimensions and Physical Characteristics of Copper Tube: TYPE M Nominalorstandard size, inches Nominal dimensions, inches Calculated values (based on nominal dimensions) Outside diameter Inside diameter Wall thickness Cross sectional area of bore, sq. inches Weight of tube only, pounds per linear ft. Weightof tube & water pounds per linear ft. Contents of tubeper linear ft Cu ft.Gal. 3/8 .500 .450 .025 .159 .145 .214 .00110 .00826 1/2 .625 .569 .028 .254 .204 .314 .00176 .0132 3/4 .875 .811 .032 .517 .328 .551 .00359 .0269 1 1.125 1.055 .035 .874 .465 .843 .00607 .0454 1-1/4 1.375 1.291 .042 1.31 .682 1.25 .00910 .0681 1-1/2 1.625 1.527 .049 1.83 .940 1.73 .0127 .0951 2 2.125 2.009 .058 3.17 1.46 2.83 .0220 .165 2-1/2 2.625 2.495 .065 4.89 2.03 4.14 .0340 .254 3 3.125 2.981 .072 6.98 2.68 5.70 .0485 .363 3-1/2 3.625 3.459 .083 9.40 3.58 7.64 .0653 .488 4 4.125 3.935 .095 12.2 4.66 9.83 .0847 .634 5 5.125 4.907 .109 18.9 6.66 14.8 .131 .982 6 6.125 5.881 .122 27.2 8.92 20.7 .189 1.41 8 8.125 7.785 .170 47.6 16.5 37.1 .331 2.47 10 10.125 9.701 .212 73.9 25.6 57.5 .513 3.84 12 12.125 11.617 .254 106 36.7 82.5 .736 5.51 Copper TubeHandbook Plumbing Site Menu Table of Contents provides a view of the full contents of this publication and the links to go to specific sections of this handbook. The entire Copper Tube Handbook can be downloaded in pdf format [7 MB]. CDA Tube, Pipe and Fittings Council members: Applications: Tube, Pipe & Fittings: Copper Tube Handbook: Table 2c - Type M Tube http://www.copper.org/applications/plumbing/techref/cth/tables/cth_table2c.htm (1 of 2)2/17/2006 1:57:15 AM Ductile Iron Threaded Fittings Ductile Iron Threaded Fittings TemperatureDegrees F Working Pressure, Non-Shock psigClass 300 Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 Specifications • branded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 psi WSP • Ductile iron castings conform to ASTM A536 • Fitting dimensions conform to ASME B16.3 • Bushings and plugs conform to ASME B16.14 • All fittings are 100% air tested • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical & mechanical properties • Manufacturing facilities are ISO 9001:2008 and ISO 14001 • ProPak™ Packaging SCI ProPak™ System SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com201 DUCTILE A A A A A A AA B Size in Part Number A in Packing Weight lbInnerMaster 1/2 35E 3004 1.13 100 200 0.2 3/4 35E 3006 1.31 70 140 0.3 1 35E 3010 1.50 40 80 0.5 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Size in Part Number A in B in Packing Weight lbInnerMaster 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2 x 1-1/4 35RE3020012 1.90 2.10 12 24 1.3 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 Size in Part Number A in Packing Weight lbInnerMaster 1/2 35F 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 160 0.3 1 35F 3010 1.13 40 80 0.5 1-1/4 35F 3012 1.29 25 50 0.7 1-1/2 35F 3014 1.44 20 40 1.0 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 Size in Part Number A in Packing Weight lbInnerMaster 1/2 35T 3004 1.13 80 160 0.3 3/4 35T 3006 1.31 30 60 0.5 1 35T 3010 1.50 25 50 0.7 1-1/4 35T 3012 1.75 10 20 1.1 1-1/2 35T 3014 1.94 10 20 1.5 2 35T 3020 2.25 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 Fig. 35E 3 – 90° Elbow Fig. 35RE3 – 90° Reducing Elbow Fig. 35F 3 – 45° Elbow Fig. 35T 3 – Tee Ductile Iron Threaded Fittings - Class 300 UL/FM SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com202 DUCTILE A B AB C C Size in Part Number A in B in C in Packing Weight lbInnerMaster 3/4 x 1/2 35RT3006004 1.20 1.20 1.22 60 120 0.4 1 x 1/2 35RT3010004 1.26 1.26 1.36 30 60 0.6 1 x 1/2 x 1 35RT3010004010 1.50 1.36 1.50 30 60 0.6 1 x 3/4 35RT3010006 1.38 1.38 1.45 25 50 0.6 1 x 3/4 x 3/4 35RT3010006006 1.38 1.31 1.45 35 70 0.6 1 x 3/4 x 1 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1-1/4 x 1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4 x 1/2 x 1-1/4 35RT3012004012 1.75 1.53 1.75 25 50 0.9 1-1/4 x 3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 1-1/4 x 3/4 x 1-1/4 35RT3012006012 1.75 1.62 1.75 20 40 1.0 1-1/4 x 1 35RT3012010 1.58 1.58 1.67 15 30 1.0 1-1/4 x 1 x 1/2 35RT3012010004 1.34 1.26 1.53 25 50 0.7 1-1/4 x 1 x 3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4 x 1 x 1 35RT3012010010 1.58 1.50 1.69 20 40 0.9 1-1/4 x 1 x 1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1-1/2 x 1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 1-1/2 x 1/2 x 1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2 x 1/2 x 1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 1-1/2 x 3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2 x 3/4 x 1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 1.1 1-1/2 x 3/4 x 1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 1-1/2 x 1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1-1/2 x 1 x 1/2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 1-1/2 x 1 x 3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1-1/2 x 1 x 1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 1-1/2 x 1 x 1-1/4 35RT3014010012 1.82 1.67 1.88 12 24 1.2 1-1/2 x 1 x 1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 1-1/2 x 1-1/4 35RT3014012 1.82 1.82 1.88 12 24 1.4 1-1/2 x 1-1/4 x 1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 1-1/2 x 1-1/4 x 3/4 35RT3014012006 1.52 1.45 1.75 16 32 1.0 1-1/2 x 1-1/4 x 1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 1-1/2 x 1-1/4 x 1-1/4 35RT3014012012 1.82 1.75 1.88 14 28 1.3 1-1/2 x 1-1/4 x 1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 2 x 1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 2 x 3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 2 x 1 35RT3020010 1.73 1.73 2.02 8 16 1.7 2 x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2 x 1-1/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 2 x 1-1/4 x 2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2 x 1-1/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 2 x 1-1/2 x 1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 2 x 1-1/2 x 3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2 x 1-1/2 x 1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2 x 1-1/2 x 1-1/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2 x 1-1/2 x 1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 Size in Part Number A in B in C in Packing Weight lbInnerMaster 3/4 x 1 35BT3006010 1.45 1.45 1.37 30 60 0.6 1 x 1-1/4 35BT3010012 1.67 1.67 1.58 20 40 0.9 1 x 1-1/2 35BT3010014 1.80 1.80 1.65 15 30 1.0 1-1/4 x 1 x 1-1/2 35BT3012010014 1.88 1.80 1.82 15 30 1.2 1-1/4 x 1-1/2 35BT3012014 1.88 1.88 1.82 15 30 1.3 1-1/4 x 2 35BT3012020 2.10 2.10 1.90 10 20 1.6 1-1/2 x 1-1/4 x 2 35BT3014012020 2.16 2.10 2.02 10 20 1.8 1-1/2 x 2 35BT3014020 2.16 2.16 2.02 8 16 1.8 Fig. 35BT3 – Bull Head Tee Fig. 35RT3 – Reducing Tee Ductile Iron Threaded Fittings - Class 300 UL/FM SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com203 DUCTILE A A A AA B Size in Part Number A in Packing Weight lbInnerMaster 1 35U 3010 2.19 20 40 1.0 1-1/4 35U 3012 2.50 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 2 35U 3020 3.12 6 12 2.4 Size in Part Number A in Packing Weight lbInnerMaster 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Size in Part Number A in Packing Weight lbInnerMaster 1 x 1/2 35RC3010004 1.69 80 160 0.3 1 x 3/4 35RC3010006 1.69 60 120 0.4 1-1/4 x 3/4 35RC3012006 2.06 40 80 0.6 2 x 1 (not hex)35RC3020010 2.81 20 40 1.0 Size in Part Number A in Packing Weight lbInnerMaster 1 x 1/2 35HB3010004 1.06 180 360 0.2 1 x 3/4 35HB3010006 1.06 180 360 0.1 1-1/4 x 1 35HB3012010 1.19 90 180 0.2 1-1/2 x 1 35HB3014010 1.25 75 150 0.4 1-1/2 x 1-1/4 35HB3014012 1.25 75 150 0.3 2 x 1 35HB3020010 1.38 40 80 0.6 2 x 1-1/4 35HB3020012 1.38 40 80 0.6 2 x 1-1/2 35HB3020014 1.38 40 80 0.6 Size in Part Number A in Packing Weight lbInnerMaster 1/2 35SP3004 0.94 600 1200 0.07 3/4 35SP3006 1.12 350 700 0.1 1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 Fig. 35CP3 – Straight Coupling with Ribs Fig. 35RC3 – Hex Reducing Coupling Fig. 35HB3 – Hex Bushing Fig. 35SP3 – Square Head Plug Fig. 35U 3 – Union with Brass Seat Ductile Iron Threaded Fittings - Class 300 UL/FM SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com204 DUCTILE A A A A A A A B B Size in Part Number A in B in Packing Weight lbInnerMaster 1-1/4 x 1 35RX3012010 1.67 1.58 15 30 1.2 1-1/2 x 1 35RX3014010 1.80 1.65 12 24 1.4 2 x 1 35RX3020010 2.02 1.73 8 16 2.0 Size in Part Number A in Packing Weight lbInnerMaster 1 35X 3010 1.50 20 40 0.9 1-1/4 35X 3012 1.75 12 24 1.4 1-1/2 35X 3014 1.94 8 16 1.8 2 35X 3020 2.25 6 12 2.8 Size in Part Number A in Packing Weight lbInnerMaster 1/2 35C 3004 0.87 300 600 0.1 3/4 35C 3006 0.97 200 400 0.1 1 35C 3010 1.16 110 220 0.2 1-1/4 35C 3012 1.28 70 140 0.4 1-1/2 35C 3014 1.33 50 100 0.5 2 35C 3020 1.45 25 50 0.8 2-1/2 35C 3024 1.70 18 36 1.6 Fig. 35X 3 – Cross Fig. 35RX3 – Reducing Cross Fig. 35C 3 – Cap Size in Part Number A in Packing Weight lbInnerMaster 3/8 35BC3003 0.75 100 200 0.3 1/2 35BC3004 0.75 80 160 0.5 Fig. 35BC3 – Beam Clamp A Ductile Iron Threaded Fittings - Class 300 UL/FM WROT CAST 101 Coupling Without Stop Wrot & Cast Pressure Fittings Couplings 4 Elkhart Products Corporation ** Cast Bronze Only *Factory Option—consult factory for price and delivery information. A A WROT CAST 101-R Coupling With Stop 4701-R Copper to Copper A C x C C x C C x C WROT CAST 100 Coupling With Stop Copper to Copper RD RPPA ETAD .LTAM ELACS ETAD .ONTRAPCPE DEIFICEPSESIWREHTOSSELNUSECNARELOTSELGNA.CED.LP3.CED.LP2.CED.LP1 )000.0()00.0()0.0(++060.+510.+500.1? PROCSTCUDORPTRAHKLEFOYTREPORPEHTSITNIRPSIHT.UTUMEHTHTIW,ESULAITNEDIFNOCROFDEHSINRUFSITI LAENNAMYNANIDESUEBTONLLIWTITAHTGNIDNATSREDNUROCSTCUDORPTRAHKLEFOSTSERETNIEHTOTLATNEMIRTED.PRIDNEPSTNETAPROSTNETAPETAROPROCNIYAMTNIRPSIHTGN.PROCSTCUDORPTRAHKLEYBDLEH ???????????????????????????????????????????????????????????????????????????????????? .ONTRAPCPE NOITPIRCSEDETADVER YB SECAFRUSLLADETONSATPECXESRRUBLLAEVOMER510.-500.SEGDEPRAHSLLAKAERB .FER NOITPIRCSED .VER .VER ??? .ONNCE 00221C-SNU 1:1 46703#CPU LLOR/WGNILPUOCMON-2/11 POTS 42-SR001 42-SR001 5002/13/5.VMAK J J 93149NSCJNCEREPD'VER6991/62/21J 42-SR001 1 TEEHS A C x C WROT CAST 100-RS Coupling With Roll Stop Copper to Copper Nominal Size Part Box Master Approx. Dim. In Inches Number Quantity Pack Net Wt. A 1/4 30896 50 1000 0.007 3/32 3/8 30898 50 1000 0.014 3/32 1/2 30900 100 1000 0.021 3/32 5/8 30902 25 500 0.040 3/32 3/4 30904 50 500 0.056 3/32 7/8 30906 10 200 0.084 3/32 1 30908 25 250 0.122 3/32 1 1/4 30910 20 200 0.144 3/32 1 1/2 30914 10 100 0.216 3/32 2 30916 5 50 0.391 3/32 2 1/2 30918 5 50 0.624 3/32 3 30920 5 40 0.909 3/32 3 1/2 30922 1 16 1.369 3/32 4 30924 2 16 1.904 3/32 5 30926 1 6 3.365 3/16 6 30928 1 6 5.262 3/16 8 30930 1 1 12.941 1/8 Nominal Size Part Box Master Approx. Dim. In Inches Number Quantity Pack Net Wt. A 1/8 30944 50 1000 0.004 11/16 1/4 30948 50 1000 0.007 23/32 3/8 30950 50 1000 0.015 55/64 1/2 30952 100 1000 0.027 1 3/32 5/8 30954 25 500 0.041 1 21/64 3/4 30956 50 500 0.056 1 19/32 1 30960 25 250 0.121 1 29/32 1 1/4 30962 20 200 0.149 2 1/32 1 1/2 30964 10 100 0.213 2 17/64 2 30966 5 50 0.391 2 49/64 2 1/2 30968 5 50 0.616 3 1/32 3 30970 5 40 0.912 3 13/32 3 1/2 30972 1 16 1.352 3 29/32 4 30974 2 16 1.878 4 13/32 5 30976 1 6 3.365 5 1/2 6 30978 1 6 5.262 6 3/8 8 30980 1 1 12.941 8 1/4 Nominal Size Part Box Master Approx. Dim. In Inches Number Quantity Pack Net Wt.A 3/16 OD 30662 50 1000 0.002 1/16 5/16 OD 30672 50 1000 0.006 1/16 1/8 30666 50 1000 0.004 1/16 1/4 30678 50 1000 0.007 3/32 3/8 30686 50 1000 0.014 3/32 1/2 30694 100 1000 0.021 3/32 5/8 30702 25 500 0.040 3/32 3/4 30712 50 500 0.056 3/32 7/8 30724 10 200 0.084 3/32 1 30730 25 250 0.122 3/32 1 1/4 30746 20 200 0.144 3/32 1 1/2 30764 10 100 0.216 3/32 2 30782 5 50 0.391 3/32 Nominal Size Part Box Master Approx. Dim. In Inches Number Quantity Pack Net Wt.A 1/4 OD x 3/16 OD 30668 50 1000 0.004 3/32 5/16 OD x 1/4 OD 30674 50 1000 0.007 3/32 3/8 OD x 5/16 OD 30680 50 1000 0.008 3/32 1/4 x 1/8 30684 50 1000 0.008 5/32 3/8 x 1/4 30688 50 1000 0.017 3/16 3/8 x 1/8 30692 50 1000 0.019 1/4 1/2 x 3/8 30696 50 1000 0.024 5/32 1/2 x 1/4 30698 50 1000 0.025 1/4 1/2 x 1/8 30700 50 1000 0.027 23/64 5/8 x 1/2 30704 25 500 0.035 5/32 5/8 x 3/8 30706 25 500 0.033 7/32 5/8 x 1/4 30708 25 500 0.043 5/16 3/4 x 5/8 30714 50 500 0.057 3/16 Wrot & Cast Pressure Fittings Couplings & Unions ** Cast Bronze Only * Factory Option - consult factory for price and delvery information.Elkhart Products Corporation 5 Nominal Size Part Box Master Approx. Dim. In Inches Number Quantity Pack Net Wt. A 3/4 x 1/2 30716 50 500 0.061 3/16 3/4 x 3/8 30718 25 500 0.054 21/64 3/4 x 1/4 30720 25 500 0.053 7/16 1 x 3/4 30734 25 250 0.098 13/32 1 x 5/8 30736 25 250 0.102 3/8 1 x 1/2 30738 25 250 0.104 7/16 1 x 3/8 30740 25 250 0.098 1/2 1 1/4 x 1 30748 10 100 0.152 5/16 1 1/4 x 3/4 30752 10 100 0.134 15/32 1 1/4 x 1/2 30756 10 100 0.176 41/64 1 1/2 x 1 1/4 30766 10 100 0.220 11/32 1 1/2 x 1 30768 10 100 0.220 7/16 1 1/2 x 3/4 30772 10 100 0.218 21/32 1 1/2 x 1/2 30776 10 100 0.219 25/32 2 x 1 1/2 30784 10 100 0.366 13/32 2 x 1 1/4 30786 10 100 0.393 21/32 2 x 1 30788 10 100 0.383 25/32 2 x 3/4 30790 10 100 0.408 1 2 x 1/2 30792 10 100 0.420 1 1/8 2 1/2 x 2 30800 5 50 0.639 15/32 2 1/2 x 1 1/2 30802 5 50 0.666 7/8 2 1/2 x 1 1/4 30804 5 50 0.664 15/16 2 1/2 x 1 30806 5 50 0.691 1 1/8 3 x 2 1/2 30816 2 20 0.946 1/2 3 x 2 30818 2 20 0.991 13/16 3 x 1 1/2 30820 2 20 1.106 1 5/32 **3 x 1 1/4 34710 - 40 1.345 - **3 x 1 34712 -25 1.352 - 3 1/2 x 3 30832 1 16 1.426 1/2 4 x 3 1/2 30840 2 32 1.960 17/32 4 x 3 30842 2 32 1.940 7/8 4 x 2 1/2 30844 2 32 2.029 1 1/8 4 x 2 30846 2 32 2.192 1 1/2 5 x 4 30850 1 6 3.310 25/32 5 x 3 30852 1 6 3.199 1 3/16 5 x 2 1/2 30854 1 6 3.115 1 7/16 5 x 2 30856 1 6 2.932 1 11/16 6 x 5 30860 1 6 4.762 1/2 6 x 4 30862 1 6 4.689 1 3/16 6 x 3 30864 1 6 4.749 1 11/16 6 x 2 1/2 30866 1 6 4.665 2 1/16 6 x 2 30868 1 6 4.780 2 3/16 8 x 6 30872 1 1 10.957 1 1/8 8 x 5 30873 1 1 11.546 1 5/8 8 x 4 30874 1 1 11.696 2 1/4 8 x 3 30876 1 1 12.800 2 11/16 8 x 2 1/2 30878 1 1 13.770 3 1/16 8 x 2 30880 1 1 14.163 3 WROT CAST 101-R Coupling With Stop-cont. 4701-R Copper to Copper A C x C WROT CAST 102 Union 4733 Copper to Copper A C x C WROT CAST 110 Eccentric Coupling Copper to Copper Nominal Size Part Box Master Approx. Dim. In Inches Number Quantity Pack Net Wt. A 3/4 x 1/2 31042 25 250 0.060 3/8 1 x 3/4 31044 10 100 0.114 13/32 1 1/4 x 1 31046 10 100 0.162 1/2 1 1/4 x 3/4 31048 10 100 0.190 3/4 Nominal Size Part Box Master Approx. Dim. In Inches Number Quantity Pack Net Wt. A 1/4 33576 25 500 0.114 13/32 3/8 33578 25 250 0.131 27/64 **3/8 37933 50 500 0.147 - 1/2 33580 25 250 0.113 1/2 **1/2 37934 25 250 0.216 - **5/8 37936 25 250 0.308 - 3/4 33582 20 200 0.261 21/32 **3/4 37937 25 150 0.313 - 1 33584 10 100 0.557 7/16 1 1/4 33585 5 50 0.698 7/16 1 1/2 33586 5 50 0.878 29/64 2 33587 2 20 1.499 15/32 **2 1/2 37947 - 10 3.250 - **3 37948 - 5 4.750 - A 6 Elkhart Products Corporation ** Cast Bronze Only *Factory Option—consult factory for price and delivery information. A A C x F C x M FTG. x F WROT CAST 103 Female Adapter 4703 Copper to Female N.P.T. WROT CAST 103-2 Female Street Adapter 4703-2 Fitting to Female N.P.T. WROT CAST 104 Male Adapter 4704 Copper to Male N.P.T. Wrot & Cast Pressure Fittings Adapters Nominal Size Part Box Master Approx. Dim. In Inches Number Quantity Pack Net Wt. A 1/8 30100 50 1000 0.029 7/16 1/4 30110 50 1000 0.031 15/32 3/8 30120 50 500 0.053 19/32 1/2 30130 50 500 0.093 7/8 3/4 30150 25 250 0.143 23/32 1 30160 20 200 0.226 31/32 1 1/4 30170 10 100 0.369 1 3/32 1 1/2 30180 10 100 0.404 1 5/32 2 30190 5 50 0.667 1 1/4 2 1/2 30200 2 20 1.228 1 1/2 ** 3 34252 - 12 2.400 - **4 34258 -12 3.820 - **5 34259 - 6 8.250 - ** 6 34263 - 4 12.000 - 1/8 x 1/4 30106 50 1000 0.033 1/2 1/4 x 1/2 30112 50 500 0.078 25/32 1/4 x 3/8 30114 50 1000 0.043 21/32 1/4 x 1/8 30116 50 1000 0.024 11/32 3/8 x 3/4 30122 25 250 0.121 3/4 3/8 x 1/2 30124 50 500 0.082 7/8 3/8 x 1/4 30126 50 1000 0.041 15/32 ** 1/2 x 1 34212 25 150 0.300 - 1/2 x 3/4 30134 25 250 0.121 29/32 1/2 x 3/8 30136 50 500 0.046 9/16 1/2 x 1/4 30138 50 500 0.044 15/32 5/8 x 3/4 30142 25 250 0.143 1 5/8 x 1/2 30144 25 250 0.102 3/4 ** 3/4 x 1 1/4 34218 10 50 0.515 - 3/4 x 1 30154 20 200 0.218 1 7/32 3/4 x 1/2 30156 25 250 0.085 19/32 ** 3/4 x 3/8 34222 25 250 0.170 - ** 1 x 1 1/2 34224 10 40 0.720 - 1 x 1 1/4 30164 10 100 0.299 1 7/32 1 x 3/4 30166 25 250 0.159 43/64 1 x 1/2 30168 10 100 0.239 11/16 ** 1 1/4 x 2 34229 5 50 0.980 - 1 1/4 x 1 1/2 30172 10 100 0.431 1 19/64 1 1/4 x 1 30174 10 100 0.238 55/64 **1 1/4 x 3/4 34233 -100 0.290 - 1 1/2 x 2 30182 5 50 0.678 1 7/16 1 1/2 x 1 1/4 30184 10 100 0.388 7/8 ** 1 1/2 x 1 34238 - 60 0.370 - 2 x 1 1/2 30192 5 50 0.730 1 3/16 Nominal Size Part Box Master Approx. Dim. In Inches Number Quantity Pack Net Wt. A 1/4 30224 50 1000 0.030 29/32 3/8 30230 50 1000 0.049 1 1/16 1/2 30236 50 500 0.084 1 3/8 3/4 30242 25 250 0.143 1 11/16 1 30248 20 200 0.214 1 31/32 1 1/4 30254 10 100 0.324 2 5/32 1 1/2 30260 10 100 0.437 2 7/16 2 30266 5 50 0.641 2 19/32 **2 1/2 34297 - 25 1.740 - ** 3 34298 - 20 2.470 - 1/2 x 3/8 30238 50 500 0.062 1 1/8 1/2 x 1/4 30240 50 500 0.041 59/64 **3/4 x 1/2 34284 25 225 0.147 - ** 1 x 3/4 34287 25 100 0.414 - *** 1 x 1/2 34288 25 250 0.153 - Nominal Size Part Box Master Approx. Dim. In Inches Number Quantity Pack Net Wt. A *1/8 30280 50 1000 0.019 13/32 1/4 30290 50 1000 0.027 15/32 3/8 30300 50 500 0.041 7/8 1/2 30310 50 500 0.064 19/32 3/4 30330 25 250 0.119 13/16 1 30342 20 200 0.170 27/32 1 1/4 30354 10 100 0.317 15/16 1 1/2 30368 10 100 0.462 7/8 2 30378 5 50 0.675 31/32 2 1/2 30388 4 40 1.267 1 21/32 3 30400 2 20 1.520 1 7/32 4 30410 1 16 2.262 1 9/32 **5 34374 - 5 8.600 - **6 34377 - 4 10.730 - 1/8 x 3/8 30282 50 1000 0.040 3/4 Wrot & Cast Pressure Fittings Adapters & Elbows ** Cast Bronze Only *Factory Option—consult factory for price and delivery information.Elkhart Products Corporation 7 FTG. x M A WROT CAST 104-2 Male Street Adapter 4704-2 Fitting to Male N.P.T. WROT CAST 104 Male Adapter-cont. 4704 Copper to Male N.P.T. WROT CAST 104-2 Male Street Adapter-cont. 4704-2 Fitting to Male N.P.T. A A FTG. x FTG. WROT CAST 105-C 90° Street Elbow-Close Ruff Fitting to Fitting Nominal Size Part Box Master Approx. Dim. In Inches Number Quantity Pack Net Wt. A 1/4 30424 50 1000 0.033 1 1/6 3/8 30430 50 1000 0.049 1 3/16 1/2 30436 50 500 0.074 1 7/16 3/4 30444 25 250 0.143 1 27/32 Nominal Size Part Box Master Approx. Dim. In Inches Number Quantity Pack Net Wt. A 1/8 31450 25 500 0.008 5/8 1/4 31452 25 500 0.013 27/32 3/8 31456 25 500 0.029 15/16 1/2 31460 25 500 0.044 1 1/32 5/8 31464 10 200 0.073 1 1/4 3/4 31468 25 250 0.086 1 13/32 1 31472 10 100 0.166 1 21/32 1 1/4 31476 5 50 0.269 1 29/32 Nominal Size Part Box Master Approx. Dim. In Inches Number Quantity Pack Net Wt. A 1/8 x 1/4 30284 50 1000 0.033 7/16 1/4 x 1/2 30292 50 500 0.069 7/8 1/4 x 3/8 30294 50 1000 0.060 63/64 1/4 x 1/8 30296 50 1000 0.014 17/32 3/8 x 3/4 30302 25 250 0.143 1 11/32 3/8 x 1/2 30304 50 500 0.072 15/16 3/8 x 1/4 30306 50 1000 0.039 5/8 1/2 x 1 30314 20 200 0.240 1 1/2 x 3/4 30316 25 250 0.135 13/16 1/2 x 3/8 30318 50 500 0.053 47/64 1/2 x 1/4 30320 50 500 0.059 5/8 5/8 x 3/4 30324 25 250 0.129 1 1/8 5/8 x 1/2 30326 25 500 0.075 11/16 ** 3/4 x 1 1/2 34329 5 50 0.596 - ** 3/4 x 1 1/4 34330 - 120 0.375 - 3/4 x 1 30336 20 200 0.234 7/8 3/4 x 1/2 30338 25 250 0.106 53/64 1 x 1 1/2 30344 10 100 0.544 1 29/32 1 x 1 1/4 30346 10 100 0.399 1 21/32 1 x 3/4 30348 25 250 0.206 1 3/32 1 x 1/2 30350 25 250 0.176 31/32 **1 1/4 x 2 34345 - 40 0.880 - 1 1/4 x 1 1/2 30358 10 100 0.523 1 45/64 1 1/4 x 1 30360 10 100 0.304 1 1/4 1 1/4 x 3/4 30362 10 100 0.273 1 1 1/2 x 2 30370 5 50 0.772 1 25/32 1 1/2 x 1 1/4 30372 10 100 0.386 1 27/64 1 1/2 x 1 30374 10 100 0.435 1 9/64 ** 2 x 2 1/2 34357 - 25 1.565 - 2 x 1 1/2 30380 5 50 0.650 1 23/64 2 x 1 1/4 30382 5 50 0.631 1 3/4 2 1/2 x 2 30390 5 50 0.931 1 9/64 Nominal Size Part Box Master Approx. Dim. In Inches Number Quantity Pack Net Wt. A 1 30452 20 200 0.232 2 5/32 1 1/4 30460 10 100 0.444 2 1/2 1 1/2 30470 10 100 0.508 2 13/16 2 30480 5 50 0.749 2 13/16 **2 1/2 34417 - 25 1.550 - ** 3 34422 - 20 2.280 - 1/2 x 3/4 30438 25 250 0.153 - 1/2 x 3/8 30440 50 500 0.045 - 3/4 x 1/2 30448 25 250 0.093 1 23/32 Wrot & Cast Pressure Fittings Elbows 8 Elkhart Products Corporation ** Cast Bronze Only *Factory Option—consult factory for price and delivery information. WROT CAST 106-2 45° Street Elbow Fitting to Copper B A A B FTG. x C C x C WROT CAST 107-C 90° Elbow-Close Ruff 4707 Copper to Copper A A C x C WROT CAST 106 45° Elbow Copper to Copper A A FTG. x FTG. WROT CAST 105-L 90° Street Elbow-Long Turn Fitting to Fitting Nominal Size Part Box Master Approx. Dim. Dim. In Inches Number Quantity Pack Net Wt.A B 1/8 31260 50 1000 0.008 3/8 3/8 1/4 31262 50 1000 0.012 3/8 3/8 3/8 31266 50 1000 0.026 13/32 13/32 1/2 31272 100 1000 0.044 25/64 25/64 5/8 31280 25 250 0.069 17/32 17/32 3/4 31288 50 500 0.096 9/16 9/16 1 31296 20 200 0.208 47/64 47/64 1 1/4 31306 25 200 0.259 15/16 15/16 1 1/2 31314 20 120 0.371 1 11/64 1 11/64 2 31322 10 80 0.805 1 29/64 1 29/64 2 1/2 31330 5 40 1.180 1 21/32 1 21/32 3 31338 3 24 1.920 1 61/64 1 61/64 3 1/2 31346 1 8 2.728 2 7/32 2 7/32 4 31352 1 8 4.557 2 17/32 2 17/32 5 31360 1 1 8.586 3 1/8 3 1/8 6 31368 1 1 15.200 3 13/16 3 13/16 8 31371 1 1 37.000 5 1/8 5 1/8 Nominal Size Part Box Master Approx. Dim. In Inches Number Quantity Pack Net Wt. A 1/8 31082 50 1000 0.006 1/8 1/4 31086 50 1000 0.013 15/64 3/8 31090 50 1000 0.024 1/4 1/2 31096 100 1000 0.034 17/64 5/8 31102 25 250 0.056 5/16 3/4 31106 50 500 0.076 3/8 1 31120 25 250 0.137 13/32 1 1/4 31128 25 200 0.229 33/64 1 1/2 31134 20 160 0.343 19/32 2 31140 10 80 0.625 25/32 2 1/2 31148 5 40 0.970 7/8 3 31156 3 24 1.460 63/64 3 1/2 31162 1 16 2.180 1 5/32 4 31168 1 8 3.800 1 11/64 5 31170 1 6 6.564 1 13/32 6 31172 1 1 11.200 1 11/16 8 31174 1 1 27.900 2 1/4 Nominal Size Part Box Master Approx. Dim. In Inches Number Quantity Pack Net Wt. A 3/8 31896 25 500 0.033 1 3/16 1/2 31902 25 250 0.057 1 7/16 3/4 31914 25 250 0.138 2 1 31926 10 100 0.251 2 15/32 1 1/4 31932 5 50 0.381 2 29/32 1 1/2 31938 5 50 0.563 3 5/16 2 31944 5 40 1.156 4 3/8 Nominal Size Part Box Master Approx. Dim. Dim. In Inches Number Quantity Pack Net Wt. A B 1/4 31186 50 1000 0.013 15/64 41/64 3/8 31190 50 1000 0.024 9/32 23/32 1/2 31194 100 1000 0.035 5/16 25/32 5/8 31198 25 250 0.059 5/16 1 3/4 31202 50 500 0.076 13/32 1 3/16 1 31206 25 250 0.134 7/16 1 7/16 1 1/4 31212 25 200 0.229 17/32 1 9/16 1 1/2 31216 20 160 0.343 19/32 1 3/4 2 31220 10 80 0.625 11/16 2 3/32 2 1/2 31224 5 40 0.965 29/32 2 7/16 3 31228 3 24 1.470 1 2 11/16 *3 1/2 31232 1 16 2.100 1 5/32 3 4 31236 1 8 3.340 1 9/32 3 1/2 Nominal Size Part Box Master Approx. Dim. Dim. In Inches Number Quantity Pack Net Wt. A B 1/2 31676 50 500 0.055 55/64 55/64 5/8 31684 25 250 0.087 1 1/16 1 1/16 3/4 31692 25 250 0.123 1 5/32 1 5/32 7/8 31702 10 100 0.210 1 15/32 1 15/32 1 31708 10 100 0.270 1 29/64 1 29/64 1 1/4 31720 10 80 0.381 1 7/8 1 7/8 1 1/2 31730 10 80 0.563 2 3/16 2 3/16 2 31740 5 30 1.156 3 3 2 1/2 31750 1 10 1.980 3 3/16 3 3/16 3 31756 1 8 3.320 4 5/8 4 5/8 3 1/2 31762 1 1 4.850 5 1/4 5 1/4 4 31770 1 1 7.400 5 7/8 5 7/8 Wrot & Cast Pressure Fittings Elbows ** Cast Bronze Only *Factory Option—consult factory for price and delivery information.Elkhart Products Corporation 9 A B A B B A FTG. x C C x C FTG. x C WROT CAST 107-C-2 90° Street Elbow -Close Ruff Fitting to Copper WROT CAST 107-L 90° Elbow-Long Turn-cont. Copper to Copper WROT CAST 107-L-2 90° Street Elbow-Long Turn Fitting to Copper WROT CAST 107-L 90° Elbow-Long Turn Copper to Copper Nominal Size Part Box Master Approx. Dim. Dim. In Inches Number Quantity Pack Net Wt. A B 1/8 31390 50 1000 0.006 3/8 49/64 1/4 31392 50 1000 0.012 3/8 3/4 3/8 31396 50 1000 0.027 13/32 15/16 1/2 31400 100 1000 0.042 29/64 1 1/32 5/8 31404 25 250 0.061 17/32 1 7/32 3/4 31408 50 500 0.103 19/32 1 13/32 1 31412 20 200 0.195 21/32 1 21/32 1 1/4 31416 25 200 0.259 7/8 1 29/32 1 1/2 31420 20 120 0.392 1 11/64 2 3/8 2 31424 10 80 0.805 1 29/64 2 27/32 2 1/2 31428 5 40 1.187 1 3/4 3 21/64 3 31432 3 24 1.960 2 3 25/32 3 1/2 31436 1 8 2.798 2 15/64 4 15/64 4 31440 1 8 4.460 2 19/32 4 13/16 Nominal Size Part Box Master Approx. Dim. Dim. In Inches Number Quantity Pack Net Wt. A B 1/8 31790 50 1000 0.008 1/2 7/8 1/4 31792 50 1000 0.019 23/64 1 1/16 3/8 31796 50 500 0.032 23/32 1 7/32 1/2 31802 50 500 0.055 55/64 1 7/16 5/8 31810 25 250 0.087 1 1/16 1 27/32 3/4 31816 25 250 0.139 1 1/8 2 1/16 1 31830 10 100 0.269 1 13/32 2 9/16 1 1/4 31838 10 80 0.381 1 7/8 2 29/32 1 1/2 31844 10 80 0.563 2 3/16 3 5/16 2 31850 5 30 1.156 2 31/32 4 3/8 2 1/2 31856 1 10 1.963 3 3/16 4 23/32 3 31862 1 8 3.300 4 5/8 6 11/32 3 1/2 31868 1 8 3.850 4 5 31/32 4 31874 1 1 5.890 4 29/64 6 23/32 Nominal Size Part Box Master Approx. Dim. Dim. In Inches Number Quantity Pack Net Wt. A B 3/16 OD 31662 50 1000 0.007 5/16 5/16 5/16 OD 31666 50 1000 0.013 9/16 9/16 1/8 31664 50 1000 0.083 1/2 1/2 1/4 31668 50 1000 0.019 3/4 3/4 3/8 31672 50 500 0.033 23/32 23/32 Wrot & Cast Pressure Fittings Elbows 10 Elkhart Products Corporation ** Cast Bronze Only * Factory Option-consult factory for price and delivery information. FTG. x C C x C WROT CAST 107-R 90°Reducer Elbow Copper to Copper WROT CAST 107-CR 90° Reducer Elbow-Close Ruff 4707 Copper to Copper A B C x C WROT CAST 107-MT 90° Elbow-Medium Turn Copper to Copper A B FTG. x C WROT CAST 107-MT-2 90° Street Elbow -Medium Turn Fitting to Copper Nominal Size Part Box Master Approx. Dim. Dim. In Inches Number Quantity Pack Net Wt. A B 3/8 x 1/4 31268 50 1000 0.027 5/8 39/64 1/2 x 3/8 31274 50 500 0.041 43/64 5/8 1/2 x 1/4 31276 50 500 0.034 11/16 43/64 5/8 x 1/2 31282 25 250 0.077 31/32 7/8 3/4 x 1/2 31290 50 500 0.085 5/8 15/32 1 x 3/4 31298 25 250 0.146 3/4 19/32 1 x 1/2 31300 25 250 0.129 1 1/8 7/8 1 1/4 x 1 31308 10 100 0.229 7/8 11/16 ** 1 1/4 x 3/4 35212 15 90 0.338 - - **1 1/4 x 1/2 35214 20 120 0.280 -- 1 1/2 x 1 1/4 31316 10 100 0.338 1 9/64 55/64 ** 1 1/2 x 1 35218 - 60 0.540 - - ** 1 1/2 x 3/4 35220 - 72 0.455 - - ** 1 1/2 x 1/2 35222 12 72 0.380 - - 2 x 1 1/2 31324 5 40 0.602 1 1/2 1 13/64 **2 x 1 1/4 35226 - 25 0.880 - - ** 2 x 1 35228 - 30 0.780 - - ** 2 x 3/4 35229 - 30 0.660 - - 2 1/2 x 2 31332 5 40 1.128 1 7/8 1 1/2 3 x 2 1/2 31340 3 24 1.598 2 3/32 1 3/4 ** 3 x 2 35242 - 20 2.753 - - 4 x 3 31354 1 8 3.313 2 11/16 2 * 5 x 4 31362 1 6 6.542 3 13/32 2 17/32 * 6 x 4 31370 1 6 8.091 3 7/8 2 17/32 Nominal Size Part Box Master Approx. Dim. Dim. In Inches Number Quantity Pack Net Wt. A B 3/8 x 1/4 31674 50 1000 0.027 39/64 5/8 1/2 x 3/8 31678 50 500 0.042 5/8 43/64 5/8 x 1/2 31686 25 250 0.077 7/8 31/32 3/4 x 3/8 31698 50 500 0.073 11/16 27/32 3/4 x 1/2 31696 50 500 0.086 7/8 7/8 3/4 x 5/8 31694 25 250 0.113 1 1/16 1 5/32 1 x 3/4 31710 25 250 0.170 1 9/64 1 1/4 1 1/2 x 1 31734 5 50 0.350 1 13/32 1 11/16 1 1/2 x 1 1/4 31732 5 50 0.480 2 2 1/4 2 x 1 1/2 31742 5 40 0.754 2 3/16 2 5/16 Nominal Size Part Box Master Approx. Dim. Dim. In Inches Number Quantity Pack Net Wt. A B 1/8 31560 50 1000 0.010 3/8 3/4 1/4 31562 50 1000 0.017 3/8 3/4 3/8 31566 50 1000 0.044 1/2 15/16 1/2 31572 50 500 0.066 19/32 1 3/16 5/8 31578 25 250 0.104 7/8 1 1/2 3/4 31584 25 250 0.146 13/16 1 5/8 1 31590 10 100 0.271 1 1/16 2 1/32 Nominal Size Part Box Master Approx. Dim. Dim. In Inches Number Quantity Pack Net Wt. A B 1/8 31510 50 1000 0.010 3/8 3/8 1/4 31512 50 1000 0.016 3/8 3/8 3/8 31516 50 1000 0.043 1/2 1/2 1/2 31522 50 500 0.068 19/32 19/32 5/8 31530 25 250 0.109 7/8 7/8 3/4 31536 25 250 0.141 13/16 13/16 1 31542 10 100 0.252 1 1 ** Cast Bronze Only *Factory Option—consult factory for price and delivery information.Elkhart Products Corporation 11 Wrot & Cast Pressure Fittings Tees WROT CAST 111 Tee-cont. 4711 Copper to Copper to Copper B C AC x C x C WROT CAST 111 Tee 4711 Copper to Copper to Copper Nominal Size Part Box Master Approx. Dim. Dim. Dim. In Inches Number Quantity Pack Net Wt. A B C 1/2 x 3/8 x 1/2 32716 50 500 0.063 3/8 17/32 11/32 1/2 x 3/8 x 3/8 32718 50 500 0.064 5/16 1/2 13/32 1/2 x 1/4 x 1/2 32724 50 500 0.063 3/8 21/32 11/32 1/2 x 1/4 x 1/4 32728 50 500 0.064 9/32 5/8 13/32 5/8 x 5/8 x 3/4 32736 25 250 0.170 11/16 11/16 17/32 5/8 x 5/8 x 1/2 32738 25 250 0.107 27/64 27/64 1/2 5/8 x 5/8 x 3/8 32740 25 250 0.107 27/64 27/64 21/32 5/8 x 5/8 x 1/4 32742 25 250 0.107 27/64 27/64 23/32 5/8 x 1/2 x 1/2 32748 25 250 0.107 27/64 5/8 1/2 3/4 x 3/4 x 1 32770 10 100 0.202 3/4 3/4 17/32 * 3/4 x 3/4 x 5/8 32772 25 250 0.153 1/2 1/2 3/4 3/4 x 3/4 x 1/2 32774 25 250 0.112 25/64 25/64 19/32 3/4 x 3/4 x 3/8 32776 25 250 0.130 25/64 25/64 11/16 3/4 x 3/4 x 1/4 32778 25 250 0.135 25/64 25/64 3/4 * 3/4 x 5/8 x 5/8 32786 25 250 0.150 1/2 11/16 3/4 3/4 x 1/2 x 3/4 32790 25 250 0.144 1/2 25/32 17/32 3/4 x 1/2 x 1/2 32794 25 250 0.109 25/64 5/8 19/32 * 3/4 x 1/2 x 3/8 32796 25 250 0.137 25/64 5/8 11/16 3/4 x 1/2 x 1/4 32798 25 250 0.140 25/64 5/8 3/4 * 3/4 x 3/8 x 3/4 32802 25 250 0.159 1/2 29/32 17/32 * 3/4 x 3/8 x 3/8 32806 25 250 0.132 25/64 23/32 11/16 1 x 1 x 1 1/2 32820 5 50 0.680 1 1/4 1 1/4 1 5/32 1 x 1 x 1 1/4 32822 5 50 0.405 1 5/32 1 5/32 31/32 1 x 1 x 3/4 32824 10 100 0.220 1/2 1/2 5/8 * 1 x 1 x 5/8 32826 10 100 0.319 1/2 1/2 15/16 1 x 1 x 1/2 32828 10 100 0.183 23/64 23/64 11/16 1 x 1 x 3/8 32830 10 100 0.183 23/64 23/64 13/16 1 x 3/4 x 1 32836 10 100 0.290 21/32 53/64 21/32 1 x 3/4 x 3/4 32838 10 100 0.220 1/2 11/16 5/8 1 x 3/4 x 1/2 32842 10 100 0.183 23/64 9/16 11/16 * 1 x 3/4 x 3/8 32844 10 100 0.270 23/64 9/16 13/16 1 x 1/2 x 1 32856 10 100 0.290 21/32 5/64 21/32 1 x 1/2 x 3/4 32858 10 100 0.220 1/2 15/16 5/8 1 x 1/2 x 1/2 32860 10 100 0.185 23/64 13/16 11/16 1 1/4 x 1 1/4 x 2 32868 5 40 1.352 1 3/4 1 3/4 1 3/8 1 1/4 x 1 1/4 x 1 1/2 32870 5 50 0.680 1 3/16 1 3/16 1 5/32 1 1/4 x 1 1/4 x 1 32872 5 50 0.348 17/32 17/32 25/32 1 1/4 x 1 1/4 x 3/4 32874 5 50 0.314 7/16 7/16 3/4 1 1/4 x 1 1/4 x 1/2 32876 5 50 0.259 19/64 19/64 11/16 1 1/4 x 1 x 1 1/4 32882 5 50 0.405 7/8 7/8 25/32 1 1/4 x 1 x 1 32884 5 50 0.391 3/4 3/4 25/32 1 1/4 x 1 x 3/4 32886 5 50 0.297 5/8 5/8 25/32 1 1/4 x 1 x 1/2 32888 5 50 0.267 1/2 1/2 25/32 1 1/4 x 3/4 x 1 1/4 32894 5 50 0.405 7/8 7/8 25/32 1 1/4 x 3/4 x 1 32896 5 50 0.391 3/4 3/4 25/32 1 1/4 x 3/4 x 3/4 32898 5 50 0.297 5/8 5/8 25/32 1 1/4 x 3/4 x 1/2 32900 5 50 0.267 1/2 1/2 25/32 1 1/4 x 1/2 x 1 1/4 32904 5 50 0.405 7/8 7/8 25/32 ** 1 1/4 x 1/2 x 1 36780 12 72 0.470 - - - ** 1 1/2 x 1/2 x 1/2 36783 5 50 0.500 - - - 1 1/2 x 1 1/2 x 2 32912 5 50 1.352 1 37/64 1 37/64 1 3/8 1 1/2 x 1 1/2 x 1 1/4 32914 5 50 0.457 11/16 11/16 13/16 1 1/2 x 1 1/2 x 1 32916 5 50 0.376 9/16 9/16 13/16 1 1/2 x 1 1/2 x 3/4 32918 5 50 0.332 7/16 7/16 13/16 1 1/2 x 1 1/2 x 1/2 32920 5 50 0.296 21/64 21/64 29/32 1 1/2 x 1 1/4 x 1 1/2 32924 5 50 0.680 1 7/32 1 3/16 1 7/32 Nominal Size Part Box Master Approx. Dim. Dim. Dim. In Inches Number Quantity Pack Net Wt. A B C 1/8 32606 50 1000 0.016 13/64 13/64 7/32 3/16 OD 32602 50 1000 0.009 3/16 3/16 3/16 5/16 OD 32622 50 1000 0.020 7/32 7/32 9/32 1/4 32640 50 1000 0.028 17/64 17/64 1/4 3/8 32668 50 500 0.045 5/16 5/16 3/8 1/2 32700 50 500 0.059 21/64 21/64 11/32 5/8 32732 25 250 0.110 7/16 7/16 1/2 3/4 32768 25 250 0.144 1/2 1/2 17/32 1 32818 10 100 0.239 41/64 41/64 19/32 1 1/4 32866 5 50 0.397 41/64 41/64 41/64 1 1/2 32910 5 50 0.540 13/16 13/16 13/16 2 32970 5 40 1.082 1 1/16 1 1/16 1 15/64 2 1/2 33030 1 10 1.967 1 21/32 1 21/32 1 11/16 3 33124 1 10 2.632 1 7/8 1 7/8 1 11/16 3 1/2 33250 1 8 4.167 2 5/32 2 5/32 2 1/4 4 33258 1 8 5.210 2 13/32 2 13/32 2 9/16 *5 33400 1 1 7.998 2 37/64 2 37/64 2 29/32 *6 33420 1 1 12.613 3 1/8 3 1/8 3 11/16 *8 33454 1 1 32.086 4 1/16 4 1/16 4 3/4 1/4 x 1/4 x 1/8 OD 32614 50 1000 0.016 5/16 5/16 7/32 1/4 x 1/4 x 1/4 OD 33492 50 1000 0.016 13/64 13/64 7/32 1/4 x 1/4 x 5/16 OD 32608 50 1000 0.020 17/64 17/64 9/32 5/16 x 5/16 x 1/4 OD 32626 50 1000 0.020 7/32 7/32 11/32 5/16 x 1/4 x 5/16 OD 32628 50 1000 0.020 7/32 11/32 9/32 5/16 x 1/4 x 1/4 OD 32630 50 1000 0.020 7/32 11/32 11/32 *3/8 x 3/8 x 3/16 OD 32650 50 1000 0.028 17/64 17/64 7/16 3/8 x 1/4 x 5/16 OD 32658 50 1000 0.028 17/64 13/32 11/32 1/8 x 1/8 x 1/4 32610 50 1000 0.028 13/32 13/32 1/4 1/4 x 1/4 x 1/2 32642 50 500 0.063 21/32 21/32 11/32 1/4 x 1/4 x 3/8 32644 50 500 0.045 15/32 15/32 3/8 1/4 x 1/4 x 1/8 32648 50 1000 0.028 17/64 17/64 13/32 1/4 x 1/8 x 1/4 32656 50 1000 0.028 17/64 13/32 1/4 1/4 x 1/8 x 1/8 32664 50 1000 0.028 17/64 13/32 13/32 3/8 x 3/8 x 1/2 32672 50 500 0.063 17/32 17/32 11/32 3/8 x 3/8 x 1/4 32674 50 500 0.045 5/16 5/16 15/32 3/8 x 3/8 x 1/8 32678 50 500 0.045 5/16 5/16 39/64 3/8 x 1/4 x 3/8 32684 50 500 0.045 5/16 15/32 3/8 3/8 x 1/4 x 1/4 32686 50 500 0.045 5/16 15/32 15/32 * 3/8 x 1/4 x 1/8 32688 50 500 0.045 5/16 15/32 5/8 3/8 x 1/8 x 3/8 32694 50 500 0.045 5/16 9/16 3/8 1/2 x 1/2 x 1 32702 10 100 0.290 15/16 15/16 3/4 1/2 x 1/2 x 3/4 32704 25 250 0.118 33/64 33/64 15/32 1/2 x 1/2 x 5/8 32706 50 500 0.110 21/32 21/32 1/2 1/2 x 1/2 x 3/8 32708 50 500 0.064 5/16 5/16 13/32 1/2 x 1/2 x 1/4 32710 50 500 0.064 9/32 9/32 13/32 1/2 x 1/2 x 1/8 32712 50 500 0.064 9/32 9/32 1/2 12 Elkhart Products Corporation ** Cast Bronze Only *Factory Option—consult factory for price and delivery WROT CAST 111 Tee-cont. 4711 Copper to Copper to Copper WROT CAST 111 Tee-cont. 4711 Copper to Copper to Copper Wrot & Cast Pressure Fittings Tees Nominal Size Part Box Master Approx. Dim. Dim. Dim. In Inches Number Quantity Pack Net Wt. A B C 1 1/2 x 1 1/4 x 1 1/4 32926 5 50 0.661 31/32 1 3/16 1 1/16 1 1/2 x 1 1/4 x 1 32928 5 50 0.591 27/32 1 3/16 1 1/16 1 1/2 x 1 1/4 x 3/4 32930 5 50 0.583 11/16 7/8 31/32 1 1/2 x 1 1/4 x 1/2 32932 5 50 0.460 9/16 13/16 31/32 1 1/2 x 1 x 1 1/2 32936 5 50 0.680 1 5/32 1 1/4 1 5/32 1 1/2 x 1 x 1 1/4 32938 5 50 0.661 31/32 1 5/16 1 1/16 1 1/2 x 1 x 1 32940 5 50 0.591 27/32 1 1/8 1 1/16 1 1/2 x 1 x 3/4 32942 5 50 0.583 11/16 1 31/32 1 1/2 x 1 x 1/2 32944 5 50 0.460 9/16 13/16 31/32 1 1/2 x 3/4 x 1 1/2 32948 5 50 0.680 1 5/32 1 19/64 1 5/32 1 1/2 x 3/4 x 1 1/4 32950 5 50 0.661 31/32 1 1/4 1 1/16 1 1/2 x 3/4 x 1 32952 5 50 0.591 27/32 1 5/16 1 1/16 1 1/2 x 3/4 x 3/4 32954 5 50 0.583 11/64 1 1/32 31/32 1 1/2 x 3/4 x 1/2 32956 5 50 0.460 9/16 15/16 31/32 1 1/2 x 1/2 x 1 1/2 32960 5 50 0.680 1 5/32 1 31/64 1 5/32 ** 1 1/2 x 1/2 x 1 1/4 36814 5 50 0.750 - - - **2 x 2 x 3 36825 -8 3.110 - - - 2 x 2 x 2 1/2 32972 1 10 1.961 2 2 1 11/16 2 x 2 x 1 1/2 32974 5 40 0.893 3/4 3/4 1 3/32 2 x 2 x 1 1/4 32976 5 40 0.742 11/16 11/16 1 1/8 2 x 2 x 1 32978 5 40 0.673 1/2 1/2 1 3/32 2 x 2 x 3/4 32980 5 40 0.624 7/16 7/16 1 5/32 2 x 2 x 1/2 32982 5 40 0.551 5/16 5/16 1 1/8 2 x 1 1/2 x 2 32984 5 40 1.352 1 3/8 1 37/64 1 3/8 2 x 1 1/2 x 1 1/2 32986 5 40 1.097 1 1/32 1 19/64 1 11/32 2 x 1 1/2 x 1 1/4 32988 5 40 1.013 31/32 1 3/16 1 3/8 2 x 1 1/2 x 1 32990 5 40 1.023 13/16 1 1/16 1 5/16 2 x 1 1/2 x 3/4 32992 5 40 0.960 11/16 1 1/16 1 1/4 2 x 1 1/2 x 1/2 32994 5 40 0.850 5/8 15/16 1 1/4 2 x 1 1/4 x 2 32998 5 40 1.352 1 3/8 1 25/32 1 3/8 2 x 1 1/4 x 1 1/2 33000 5 40 1.097 1 1/32 1 3/8 1 11/32 2 x 1 1/4 x 1 1/4 33002 5 40 1.013 31/32 1 3/16 1 3/8 2 x 1 1/4 x 1 33004 5 40 1.023 13/16 1 9/32 1 5/16 2 x 1 1/4 x 3/4 33006 5 40 0.960 11/16 1 5/32 1 1/4 2 x 1 1/4 x 1/2 33008 5 40 0.850 5/8 1 5/64 1 1/4 2 x 1 x 2 33012 5 40 1.352 1 3/8 1 25/32 1 3/8 ** 2 x 1 x 1 1/2 36852 - 25 1.150 - - - 2 x 1 x 1 33016 5 40 1.023 27/32 1 9/32 1 11/32 2 x 3/4 x 2 33020 5 40 1.352 1 3/8 1 3/4 1 3/8 2 x 3/4 x 3/4 36862 - 50 0.890 - - - 2 x 1/2 x 2 33024 5 40 1.352 1 3/8 1 7/8 1 3/8 2 1/2 x 2 1/2 x 3 33032 1 10 2.744 2 5/8 2 5/8 1 7/8 2 1/2 x 2 1/2 x 2 33034 1 10 1.673 1 7/16 1 7/16 1 11/16 2 1/2 x 2 1/2 x 1 1/2 33036 1 10 1.460 1 3/16 1 3/16 1 19/32 2 1/2 x 2 1/2 x 1 1/4 33038 1 10 1.341 1 1 1 39/64 2 1/2 x 2 1/2 x 1 33040 1 10 1.356 7/8 7/8 1 5/8 2 1/2 x 2 1/2 x 3/4 33042 1 10 1.258 3/4 3/4 1 31/64 2 1/2 x 2 1/2 x 1/2 33044 1 10 1.081 1/2 1/2 1 1/2 2 1/2 x 2 x 2 1/2 33046 1 10 1.961 1 21/32 2 1 11/16 2 1/2 x 2 x 2 33048 1 10 1.673 1 7/16 2 3/64 1 11/16 2 1/2 x 2 x 1 1/2 33050 1 10 1.460 1 3/16 1 3/4 1 19/32 2 1/2 x 2 x 1 1/4 33052 1 10 1.341 1 1 11/16 1 39/64 2 1/2 x 2 x 1 33054 1 10 1.356 7/8 1 9/16 1 5/8 2 1/2 x 2 x 3/4 33056 1 10 1.258 3/4 1 3/8 1 31/64 2 1/2 x 2 x 1/2 33058 1 10 1.081 1/2 1 11/32 1 1/2 2 1/2 x 1 1/2 x 2 1/2 33062 1 10 1.961 1 21/32 2 21/32 1 11/16 2 1/2 x 1 1/2 x 2 33064 1 10 1.673 1 7/16 2 15/32 1 11/16 Nominal Size Part Box Master Approx. Dim. Dim. Dim. In Inches Number Quantity Pack Net Wt. A B C 2 1/2 x 1 1/2 x 1 1/2 33066 1 10 1.460 1 3/16 2 19/64 1 19/32 2 1/2 x 1 1/2 x 1 1/4 33068 1 10 1.341 1 2 3/16 1 39/64 2 1/2 x 1 1/4 x 2 1/2 33076 1 10 1.961 1 21/32 2 31/32 1 11/16 2 1/2 x 1 1/4 x 2 33078 1 10 1.673 1 7/16 2 45/64 1 11/16 2 1/2 x 1 x 2 1/2 33092 1 10 1.961 1 21/32 3 7/32 1 11/16 2 1/2 x 3/4 x 2 1/2 33108 1 10 1.961 1 21/32 3 7/16 1 11/16 ** 2 1/2 x 1/2 x 2 1/2 36916 10 20 2.460 - - - 3 x 3 x 4 33126 1 8 6.396 3 21/32 3 21/32 2 9/16 3 x 3 x 2 1/2 33128 1 10 2.351 1 11/16 1 11/16 1 31/32 3 x 3 x 2 33130 1 10 2.270 1 7/16 1 7/16 1 31/32 3 x 3 x 1 1/2 33132 1 10 2.024 1 3/16 1 3/16 1 29/32 3 x 3 x 1 1/4 33134 1 10 1.939 31/32 31/32 1 59/64 3 x 3 x 1 33136 1 10 1.757 7/8 7/8 1 59/64 3 x 3 x 3/4 33138 1 10 1.691 3/4 3/4 1 13/16 3 x 3 x 1/2 33140 1 10 1.542 9/16 9/16 1 11/16 3 x 2 1/2 x 3 33144 1 10 2.744 1 7/8 2 5/8 1 7/8 3 x 2 1/2 x 2 1/2 33146 1 10 2.351 1 11/16 2 13/32 1 31/32 3 x 2 1/2 x 2 33148 1 10 2.270 1 7/16 2 1/8 1 31/32 3 x 2 1/2 x 1 1/2 33150 1 10 2.024 1 3/16 1 7/8 1 29/32 3 x 2 1/2 x 1 1/4 33152 1 10 1.939 31/32 1 3/4 1 59/64 3 x 2 1/2 x 1 33154 1 10 1.757 7/8 1 5/8 1 59/64 3 x 2 1/2 x 3/4 33156 1 10 1.691 3/4 1 17/32 1 13/16 3 x 2 x 3 33162 1 10 2.744 1 7/8 3 1/16 1 7/8 3 x 2 x 2 1/2 33164 1 10 2.351 1 11/16 2 23/32 1 31/32 3 x 2 x 2 33166 1 10 2.270 1 7/16 2 9/16 1 31/32 3 x 2 x 1 1/2 33168 1 10 2.024 1 3/16 2 5/16 1 29/32 * 3 x 2 x 1 1/4 33170 1 10 1.939 31/32 2 3/16 1 59/64 * 3 x 2 x 1 33172 1 10 1.757 7/8 2 1 59/64 3 x 1 1/2 x 3 33180 1 10 2.744 1 7/8 3 9/16 1 7/8 * 3 x 1 1/2 x 2 1/2 33182 1 10 2.351 1 11/16 3 5/16 1 31/32 * 3 x 1 1/2 x 2 33184 1 10 2.270 1 7/16 3 1/8 1 31/32 3 x 1 1/2 x 1 1/2 33186 1 10 2.024 1 3/16 2 25/32 1 29/32 * 3 x 1 1/4 x 3 33196 1 10 2.744 1 7/8 3 23/32 1 7/8 3 x 1 x 3 33214 1 10 2.744 1 7/8 3 29/32 1 7/8 3 x 3/4 x 3 33232 1 10 2.744 1 7/8 4 1/32 1 7/8 4 x 4 x 3 33262 1 8 5.714 2 1/32 2 1/32 2 1/2 4 x 4 x 2 1/2 33264 1 8 5.361 1 25/32 1 25/32 2 19/32 4 x 4 x 2 33266 1 8 4.880 1 1/2 1 1/2 2 7/16 4 x 4 x 1 1/2 33268 1 8 4.985 1 3/16 1 3/16 2 9/16 4 x 4 x 1 1/4 33270 1 8 4.715 1 3/32 1 3/32 2 1/2 4 x 4 x 1 33272 1 8 4.502 15/16 15/16 2 5/16 4 x 4 x 3/4 33274 1 16 2.393 13/32 13/32 2 5/16 4 x 4 x 1/2 33276 1 16 2.296 1/2 1/2 2 5/16 4 x 3 x 4 33280 1 8 6.396 2 13/32 3 21/32 2 35/64 4 x 3 x 3 33282 1 8 5.714 2 1/32 3 1/32 2 1/2 4 x 3 x 2 1/2 33284 1 8 5.361 1 25/32 2 29/32 2 19/32 4 x 3 x 2 33286 1 8 4.880 1 1/2 2 23/32 2 7/16 4 x 2 1/2 x 4 33300 1 8 6.396 2 13/32 4 1/16 2 35/64 4 x 2 1/2 x 2 1/2 33304 1 8 5.361 1 25/32 3 5/16 2 19/32 4 x 2 x 4 33320 1 8 6.396 2 13/32 4 1/2 2 35/64 4 x 2 x 2 33326 1 8 4.880 1 1/2 3 17/32 2 7/16 4 x 1 1/2 x 4 33340 1 8 6.396 2 13/32 4 29/32 2 35/64 4 x 1 x 4 33380 1 8 6.396 2 13/32 5 9/32 2 25/64 * 5 x 5 x 4 33404 1 6 6.950 2 7/64 2 7/64 2 15/16 * 5 x 5 x 3 33406 1 6 5.604 1 9/16 1 9/16 2 15/16 *5 x 5 x 2 1/2 33408 1 6 5.511 1 13/32 1 13/32 2 15/16 *5 x 5 x 2 33410 1 6 4.824 1 5/64 1 5/64 2 7/8 ** Cast Bronze Only *Factory Option—consult factory for price and delivery information.Elkhart Products Corporation 13 Wrot & Cast Pressure Fittings Tees & Plugs WROT CAST 111 Tee-cont. 4711 Copper to Copper to Copper A B C A C x FTG. x C C x F x C WROT CAST Baseboard Tee 4714-B Copper to Female N.P.T. to Copper WROT CAST 116 Fitting End Plug For Fitting WROT CAST 111-2 Street Tee Copper to Fitting to Copper A C B Nominal Size Part Box Master Approx. Dim. Dim. Dim. In Inches Number Quantity Pack Net Wt. A B C * 5 x 5 x 1 1/2 33412 1 6 4.479 27/32 27/32 2 7/8 *5 x 5 x 1 1/4 33414 1 6 4.276 3/4 3/4 2 7/8 * 5 x 5 x 1 33416 1 6 4.050 21/32 21/32 2 7/8 * 5 x 5 x 3/4 33418 1 6 3.841 5/8 5/8 2 7/8 * 5 x 4 x 5 33398 1 1 10.087 2 37/64 4 1/8 29/32 * 5 x 4 x 4 33399 1 1 8.101 2 1/8 3 29/64 2 15/16 * 6 x 6 x 5 33424 1 1 11.580 2 45/64 2 45/64 3 7/16 * 6 x 6 x 4 33426 1 1 10.132 2 13/64 2 13/64 3 7/16 * 6 x 6 x 3 33428 1 1 8.093 1 11/16 1 11/16 3 7/16 * 6 x 6 x 2 1/2 33430 1 1 7.663 1 7/16 1 7/16 3 7/16 * 6 x 6 x 2 33432 1 1 7.132 1 17/32 1 17/32 3 7/16 * 6 x 6 x 1 1/2 33434 1 6 6.716 15/16 15/16 3 7/16 * 6 x 6 x 1 1/4 33436 1 6 6.454 13/16 13/16 3 7/16 * 6 x 6 x 1 33438 1 6 6.168 11/16 11/16 3 7/16 *6 x 6 x 3/4 33440 1 6 5.885 5/8 5/8 3 7/16 *6 x 6 x 1/2 33441 1 6 5.668 11/32 11/32 3 11/32 * 6 x 4 x 6 33443 1 1 13.252 3 1/8 4 23/32 3 11/16 * 6 x 4 x 4 33446 1 1 10.103 2 13/64 4 3/16 3 7/16 *8 x 8 x 6 33456 1 1 26.140 3 1/16 3 1/16 4 1/2 * 8 x 8 x 5 33458 1 1 23.380 2 9/16 2 9/16 4 1/2 *8 x 8 x 4 33460 1 1 20.706 2 1/16 2 1/16 4 9/16 * 8 x 8 x 3 33462 1 1 18.308 1 1/2 1 1/2 4 1/2 * 8 x 8 x 2 1/2 33464 1 1 17.650 1 23/64 1 23/64 4 9/16 * 8 x 8 x 2 33466 1 1 17.199 1 1/16 1 1/16 4 1/2 *8 x 6 x 6 33468 1 1 25.984 3 1/16 4 1/2 4 1/2 Nominal Size Part Box Master Approx. Dim. Dim. Dim. In Inches Number Quantity Pack Net Wt. A B C 1/2 33506 50 500 0.069 3/8 1 1/32 3/8 3/4 33508 25 250 0.147 1/2 1 7/16 15/32 Nominal Size Part Box Master Approx. Dim. Dim. Dim. In Inches Number Quantity Pack Net Wt. A B C ** 1/2 x 1/8 x 1/2 37852 40 320 0.110 - - - ** 1/2 x 1/8 x 3/4 37850 20 160 0.170 - - - ** 3/4 x 1/8 x 3/4 37855 35 210 0.186 - - - ** 1 x 1/8 x 1 37857 15 90 0.300 - - - ** 1 1/4 x 1/8 x 1 1/4 37858 - 45 0.501 - - - Nominal Size Part Box Master Approx. Dim. In Inches Number Quantity Pack Net Wt.A * 3/8 32020 50 1000 0.010 1/16 1/2 32022 100 1000 0.016 3/32 3/4 32026 50 500 0.036 1/8 1 32028 25 250 0.059 5/32 14 Elkhart Products Corporation ** Cast Bronze Only *Factory Option—consult factory for price and delivery information. Wrot & Cast Pressure Fittings Caps & Reducers A A FTG. x C WROT CAST 117 Tube Cap 4717 For Tube End WROT CAST 118 Fitting Reducer Fitting to Copper WROT CAST 118 Fitting Reducer-cont. Fitting to Copper Nominal Size Part Box Master Approx. Dim. In Inches Number Quantity Pack Net Wt. A 1/8 30620 50 1000 0.003 1/32 1/4 30622 50 1000 0.005 1/16 3/8 30624 50 1000 0.010 3/32 1/2 30626 100 1000 0.016 5/64 5/8 30628 25 500 0.030 1/8 3/4 30630 50 500 0.036 5/64 1 30632 50 500 0.059 1/8 1 1/4 30634 25 250 0.108 5/32 1 1/2 30636 20 200 0.159 5/32 2 30638 10 100 0.284 5/32 2 1/2 30640 5 50 0.469 5/32 3 30642 5 50 0.713 3/16 3 1/2 30644 1 10 0.970 3/16 4 30646 1 10 1.384 7/32 **5 34647 - 5 5.484 - **6 34648 - 5 9.670 - Nominal Size Part Box Master Approx. Dim. In Inches Number Quantity Pack Net Wt. A 1/4 OD x 1/8 OD 32040 50 1000 0.004 33/64 1/4 x 1/8 32042 50 1000 0.007 1/2 3/8 x 1/4 32044 50 1000 0.014 17/32 3/8 x 1/8 32046 50 1000 0.016 5/8 1/2 x 3/8 32048 50 1000 0.025 23/32 1/2 x 1/4 32050 50 1000 0.022 47/64 5/8 x 1/2 32054 25 500 0.033 25/32 5/8 x 3/8 32056 25 500 0.029 29/32 5/8 x 1/4 32058 25 500 0.038 15/16 3/4 x 5/8 32062 50 500 0.052 15/16 3/4 x 1/2 32064 50 500 0.058 1 Nominal Size Part Box Master Approx. Dim. In Inches Number Quantity Pack Net Wt. A 3/4 x 3/8 32066 50 500 0.037 1 1/16 3/4 x 1/4 32068 50 500 0.049 1 1/8 1 x 3/4 32072 25 250 0.092 1 3/16 1 x 5/8 32074 25 250 0.089 1 7/32 1 x 1/2 32076 25 250 0.095 1 9/32 1 x 3/8 32078 25 250 0.088 1 3/8 1 1/4 x 1 32082 10 100 0.150 1 1/4 1 1/4 x 3/4 32084 10 100 0.118 1 11/32 1 1/4 x 1/2 32086 10 100 0.169 1 15/32 1 1/2 x 1 1/4 32090 10 100 0.206 1 19/64 1 1/2 x 1 32092 10 100 0.203 1 17/32 1 1/2 x 3/4 32094 10 100 0.200 1 11/16 1 1/2 x 1/2 32096 10 100 0.207 1 7/8 2 x 1 1/2 32102 10 100 0.374 1 11/16 2 x 1 1/4 32104 10 100 0.360 1 15/16 2 x 1 32106 10 100 0.357 2 1/8 2 x 3/4 32108 10 100 0.403 2 11/32 2 x 1/2 32110 10 100 0.426 2 7/16 2 1/2 x 2 32114 5 50 0.643 1 15/16 2 1/2 x 1 1/2 32116 5 50 0.666 2 1/4 2 1/2 x 1 1/4 32118 5 50 0.628 2 5/16 2 1/2 x 1 32120 5 50 0.655 2 17/32 3 x 2 1/2 32126 2 20 0.893 2 3/32 3 x 2 32128 2 20 0.948 2 33/64 3 x 1 1/2 32130 2 20 1.027 2 11/16 3 x 1 1/4 32132 2 20 1.029 2 25/32 3 1/2 x 3 32136 1 10 1.336 2 1/4 3 1/2 x 2 1/2 32138 1 10 1.344 2 7/16 3 1/2 x 2 32140 1 10 1.380 2 51/64 4 x 3 1/2 32144 2 32 1.850 2 23/32 4 x 3 32146 2 32 1.860 2 15/16 4 x 2 1/2 32148 2 32 1.929 3 7/32 4 x 2 32150 2 32 2.003 3 17/32 5 x 4 32154 1 6 3.240 3 11/32 5 x 3 32156 1 6 3.168 3 13/16 5 x 2 1/2 32158 1 6 3.084 4 9/64 5 x 2 32160 1 6 2.901 4 7/16 6 x 5 32164 1 6 4.642 3 7/8 6 x 4 32166 1 6 4.556 4 3/8 6 x 3 32168 1 6 4.388 4 23/32 6 x 2 1/2 32170 1 6 4.304 5 1/32 6 x 2 32172 1 6 4.517 5 7/32 8 x 6 32176 1 1 10.643 5 7/32 8 x 5 32178 1 1 11.379 5 23/32 8 x 4 32180 1 1 11.244 6 3/32 8 x 3 32182 1 1 12.291 6 19/32 Agency Listings T-Tap Waterflow Detectors System Sensor T-Tap Waterflow Detectors are designed for primary signaling in residential systems and branch line signaling in larger systems. Features • Sealed retard mechanism (Model WFDT) • Visual switch activation (Model WFDT) • Twelve different flexible plastic paddles • Vertical or horizontal mount • Durable, tamper-resistant enclosure • Dual SPDT switches in durable terminal block • Sizes marked on flexible plastic paddles • 100 percent synchronization activates both alarm panel and local bell • Accommodates up to 12 AWG wire Both the WFDT retard model and the WFDTNR non-retard model fit any tee that has a 1˝ NPT branch, including: 1˝, 1¼˝, 1½˝ and 2˝ NPT threaded ferrous and brass tees; 1˝, 1¼˝, 1½˝ and 2˝ copper sweat tees; Tyco, Spears®, Victaulic® and NIBO brand 1˝ CPVC tees; and 1½˝ polybutylene tees. Design. The design of the WFDT and WFDTNR makes them easy to install and simple to maintain. Either can be mounted in the vertical or horizontal position. Two conduit openings permit easy attachment to the local alarm system. The retard mechanism (Model WFDT only) and switch assemblies are field-replaceable. Features. Twelve different flexible plastic paddles fit 1˝, 1¼˝, 1½˝ and 2˝ tees. Sizes are marked clearly on the paddles for ease of installation. Plastic paddles slip over the actuating lever and are securely fastened with one screw. The handy depth gauge ensures the proper installation depth and clearance of the detector to the tee. Construction. The WFDT and WFDTNR include a durable, tamper- resistant enclosure and rugged switch assembly. The robust covers completely enclose the electrical components to keep out dust and dirt. Improved self-guiding security screws and removal tools make the detectors resistant to tampering and simplify field maintenance. Dual SPDT switches are enclosed in a durable terminal block for added strength. S739 167-93-E7770-1653:114CS169 3033305 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2010 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet.A05-0195-014 • 7/10 • #2450 T-Tap Waterflow Detector Specifications Architectural/Engineering Specifications Model shall be a WFDT or WFDTNR as manufactured by System Sensor. T-tap waterflow detectors shall be installed on a tee that has a 1˝ NPT branch including: 1˝, 1¼˝, 1½˝ or 2˝ threaded ferrous or brass tee; 1–2˝ copper sweat tees; Tyco, Spears,® Victaulic,® and NIBCO brand 1˝ CPVC tees; or 1½˝ polybutylene tee as designated on the drawings and/or as specified herein. Detectors shall mount on any clear pipe span of the appropriate size, either a vertical or horizontal run at least 6˝ from any fittings or valves that may change water direction, flow rate, or pipe diameter or no closer than 24˝ from a valve or drain. Detectors shall have a sensitivity in the range of 4 to 10 gallons per minute and a static pressure rating of 250 psi. The retard t-tap detector shall be a sealed mechanical pneumatic unit with visual indication of actuation. The actuation mechanism shall include a polyethylene vane inserted through the tee fitting and connected by a mechanical linkage to the delay mechanism. The non-retard t-tap detector shall respond with no time delay to waterflow in the specified direction and range. Outputs shall consist of dual SPDT switches (Form C contacts). Two conduit entrances (one of which is a knockout type) for standard fittings of commonly used electrical conduit shall be provided on the detectors. A grounding provision is provided. All detectors shall be listed by Underwriters Laboratories for indoor or outdoor use. Physical/Operating Specifications Static Pressure Rating 250 PSI Operating Temperature Range 32°F to 120°F (0°C to 49°C) Maximum Surge 18 FPS Enclosure Rating UL indoor/outdoor rated Triggering Threshold Bandwidth (Flow Rate) 4–10 GPM Cover Tamper Switch UL models: optional P/N 546-7000 ULC/Canadian models: factory installed Overall Dimensions, Installed WFDT: 4.5˝ H × 3.75˝ W × 6.7˝ L (11.4cm H × 9.5cm W × 17cm L) WFDTNR: 3.75˝ H × 3.25˝ W × 4.25˝ L (9.5cm H × 8.2cm W × 10.8cm L) Service Use Automatic Sprinkler: NFPA 13 One or Two Family Dwelling: NFPA 13D Residential Occupancies up to 4 Stories: NFPA 13R National Fire Alarm Code: NFPA 72 Contact Ratings Two sets of SPDT (Form C) 10.0 A @ 125/250 VAC 2.5 A @ 24 VDC Shipping Weight WFDT: 2.6 lbs. (1.2 kg.) WFDTNR: 1.5 lbs. (0.7 kg.) Compatible Tee Fittings Threaded ferrous and brass tees, copper sweat tees, CPVC tees, and polybutylene tees Warranty 3 years Conduit Entrances Two openings for ½˝ conduit.U.S. Patent Numbers 5,213,205 DELAYADJUSTMENTDIAL 557001545 3 0TIME D E LAY IN SECONDSNUMBER O N DIAL IS APPROXIMA T E NOTE: RETARD TIME MAY EXCEED 90 SECONDS. ADJUST AND VERIFY THAT TIME DOES NOT EXCEED 90 SECONDS. NUMBER ON DIAL IS APPROXIMATE TIME DELAY IN SECONDS WITH AN ACCURACY OF +/- 50%. Delay Adjustment Dial + + – – SSM24-XSSV120-X NOTE: COMMON AND B-NO CONNECTIONS WILL CLOSE WHEN VANE IS DEFLECTED, I.E., WHEN WATER IS FLOWING. DUAL SWITCHES PERMIT APPLICATIONS TO BE COMBINED ON A SINGLE DETECTOR. BREAK WIRE AS SHOWN FOR SUPERVISION OF CONNECTION. DO NOT ALLOW STRIPPED WIRE LEADS TO EXTEND BEYOND SWITCH HOUSING. DO NOT LOOP WIRES. POWER 24VDC OR 120VAC INITIATING LOOP UL-LISTED COMPATIBLE CONTROL PANEL CONTACT RATINGS 125/250 VAC24 VDC 10 AMPS2.5 AMPS SCHEMATIC OF INDIVIDUAL SWITCH IN“NO WATERFLOW” CONDITION SUGGESTED EOL RESISTOR B-NO COM A-NC Electrical Connections for WFDT Ordering Information UL Model ULC Model Description WFDT WFDTA Waterflow Detector, Fits 1˝, 1¼˝, 1½˝, 2˝ ferrous and brass threaded tees; 1˝, 1¼˝, 1½˝, 2˝ copper sweat tees; 1˝ CPVC tees; and 1½˝ polybutylene tees WFDTNR —Waterflow Detector, non-retard, fits same tees as Model WFDT Accessories Description A77-01-02 Replacement terminal block for WFDT A77-01-08 Replacement terminal block for WFDTNR A3008-00 Replacement retard mechanism PRK9 Replacement paddle kit – 12 paddles for WFDT and WFDTNR (see WFDT for sizes) 546-7000 Cover tamper switch kit for WFDT S07-66-02 Replacement tamper screws for covers of WFDT, WFDTNR WFDW Replacement tamper-proof wrench for cover of WFDT, WFDTNR WFDN4 NEMA-4 gasket kit C58-164-01 Replacement metal cover C58-195-01 Replacement plastic cover (WFDTNR) Spears® is a registered trademark of the Spears Manufacturing Company. Victaulic® is a registered trademark of the Victaulic Company of America. PRINTED IN USA RBVS UNIVERSAL BALL VALVE SWITCH PAGE 1 OF 2MFG.# 5401086 - REV U 5/08 US Patent No. 6,945,509 General The Model RBVS is designed to monitor the fully open position of a ball valve installed in a sprinkler system. The unit will fi t on most ball valves installed on back-fl ow-preventers and alarm trim lines of dry, alarm, and deluge sprinkler valves. The switch operates if the ball valve handle is moved from the open position. However, the switch does not track the position of the handle or ball. When the ball valve handle is in the open position, a spring-loaded switch button will contact the valve handle. When the handle is moved from the open position, this switch button extends to the tripped position, and the RBVS contacts change state, thereby opening or closing a circuit. A cover tamper switch is available and is activated by the removal of the RBVS housing cover. If an attempt is made to remove the RBVS by the removal of the mounting brackets, the unit will be set into the tripped mode by this action. The RBVS can be mounted to the hex portion of the ball valve or back-fl ow- preventer or to the adjoining pipe via two clamps. The RBVS is shipped with two sets of mounting clamps to accommodate various pipe and valve sizes, refer to Table 1. An "L" shaped and offset bracket for mounting the switch enclosure and an extension bracket add to the mounting fl exibility of the RBVS. See "Typical Mounting Diagram" and "Installation and Operation" on following page. Testing The RBVS and its associated protective monitoring system should be tested in accordance with applicable NFPA codes and standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). UL and cUL Listed, FM, CSFM Approved Dimensions: (including mounting clamps) Large Clamps: 6" L x 5" W x 5.2" H 15,2 cm L x 12,7 cm W x 13,2 cm H Small Clamps: 6" L x 4" W x 5.2" H 15,2 cm L x 10,2 cm W x 13,2 cm H Weight: With Large Clamps: 13.6 oz. (386,9 g.) With Small Clamps: 11.0 oz. (311,2 g.) Enclosure: Non-Corrosive Composite Material Environmental Limitations: • NEMA 4 rated enclosure when proper electrical fi ttings are used. (IP67) • Temperature range: -40°F to 150°F (-40°C to 65°C) • Not for use in hazardous locations Housing Cover Tamper: Activated by housing cover removal (Stock No. 1000035 only) Contact Ratings: SPDT Contacts: 10A at 125/250 VAC 2A at 30 VDC SPDT Cover Tamper: 3A at 250 VAC Fig.1 Internal Components Potter Electric Signal Company, LLC • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com RBVS Stock No. 1000040 (w/o Cover Tamper) RBVS-T Stock No. 1000035 (w/Cover Tamper) Installation On Lever Handle (See Fig. 2) 1. Select clamps and clamping bolts based upon pipe/valve size, see Table 1. 2. Insert rubber clamp grippers into clamps, see Fig. 2. 3. Place one clamp on top of pipe/ball valve near the valve handle and insert clamping bolts through it. 4. Place other clamp over clamping bolts from beneath the installation and thread hex nuts onto the clamping bolts, but do not fully tighten, (be sure hex nuts seat properly in clamp hex recesses). (NOTE: Some installations may require one of the mounting bolts to be inserted from the bottom of the brackets and then trimmed to allow the extension bracket to clear. See Fig. 4) 5. Attach extension bracket (if necessary to use for positioning) to top clamp using ¼-20 X ¾" Hex bolt and washer, but do not fully tighten. 6. Attach "L" bracket (RBVS switch enclosure is loosely attached to "L" bracket) to extension bracket using ¼-20 X ¾" Hex bolt and washer, but do not fully tighten. 7. Be sure ball valve is in the fully open position. 8. Slide loosely assembled RBVS switch enclosure to a position that permits the switch button to contact the valve handle approximately 1" from its inside end. See Fig. 1 for approximate location. Cut and remove the plastic coating from the ball valve handle to allow the RBVS switch button to contact (and be activated by) the metal of the handle. 9. Tighten clamping screws alternately to an eventual 30 in-lbs. (minimum) of torque. 10. Maintain position of switch enclosure over valve handle and secure bolt that holds the extension bracket to the clamping assembly. It may be necessary to close valve to access this bolt. 11. Position "L" bracket so that it contacts the back edge of the valve handle, and secure its bolt. It may be necessary to close valve to access this bolt. 12. With the actuator fully retracted, position RBVS switch enclosure to contact the valve handle squarely, see Fig. 1. 13. With RBVS switch enclosure held squarely in contact with valve handle, securely tighten the two tamper resistant screws on the backside of the enclosure. 14. Close and open the valve to verify operation. The actuator should easily retract when the valve handle is in the open position. 15. Fully open the valve. 16. Remove the cover and wire main switch and tamper switch if applicable. Carefully route tamper switch wires through strain relief channel in switch enclosure. Fully seat the wires into the bottom of the channel. See Fig. 1.17. Replace RBVS switch enclosure cover and securely tighten cover screw. PRINTED IN USA RBVS UNIVERSAL BALL VALVE SWITCH MFG.# 5401086 - REV U 5/08 PAGE 2 OF 2 OUTG O I N G INCO M I N G DWG# 923-3 Installation on Tee Handle (See Fig. 3)1. Select clamps and clamping bolts based upon pipe/valve size, see Table 1. 2. Insert rubber clamp grippers into clamps, See Fig. 3.3. Place one clamp on top of pipe/ball valve near the valve handle and insert clamping bolts through it.4. Place other clamp over clamping bolts from beneath the installation and thread hex nuts onto the clamping bolts, but do not fully tighten, (be sure hex nuts seat properly in clamp hex recesses). 5. Loosely attach "L" bracket to the "offset" bracket and "offset" bracket to the RBVS housing. 6. Be sure ball valve is in the fully open position.7. Slide loosely assembled RBVS switch enclosure to a position that permits the switch button to contact the valve handle approximately 1/2" from the end of the handle. Cut and remove the plastic coating from the ball valve handle to allow the RBVS switch button to contact (and be activated by) the metal of the handle. 8. Tighten clamping screws alternately and ¼-20 X ¾" bolt to 30 in-lbs. (minimum) of torque. 9. With the valve handle fully open, slide the RBVS housing down until the switch operates plus 1/8 inch. Tighten the screws holding the RBVS to the "offset" bracket.10. Remove the RBVS switch enclosure cover. 11. Close and open the valve to verify operation. The actuator should easily retract up when the valve handle is in the open position. 12. Fully open the valve.13. Wire main switch and tamper switch (if applicable). Carefully route tamper switch wires through strain relief channel in switch enclosure. Fully seat the wires into the bottom of the channel. See Fig. 1. 14. Replace RBVS switch enclosure cover and securely tighten cover screw. Fig. 3 Typical Electrical Connections Fig. 2 Typical Mounting Diagram Tamper Switch Connections Switch Terminal Connections, Clamping Plate Terminal Table 1 Clamp Sizing Fig. 4 SOME INSTALLATIONS MAY CAUSE INTERFERENCE BETWEEN MOUNTING BOLT AND OFFSET BRACKET. INSTALL BOLT FROM BOTTOM AND TRIM AS NEEDED TO CORRECT. RBVS PIPE DWG# 1086-6 Pipe Valve/Size Clamp Clamping Bolts 1/2" to 3/4" (12,5 to 19mm) Small 10-32 x 2 1/2 1" to 2" (25 to 50mm) Large 1/4-20 x 4" An uninsulated section of single conductor should not be looped around the terminal and serve as two seperate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. Agency Listings Features • Plug-in design • Field selectable candela settings: 135, 150, 177, 185 • Tamper resistant construction • Outdoor products rated from –40°F to 151°F • Regulated 120VAC • Rotary switch for horn tone and three volume selections • Outdoor products listed to UL 1638 (strobe) and UL 464 (horn) outdoor requirements • Outdoor products rainproof per UL 50 (NEMA 3R) • Weatherproof back box included • Single screw attachment • Horn/strobe, 120VAC adapter mounting plate, and weatherproof back box included • Listed for ceiling or wall mounting The SpectrAlert Advance series of notification appliances is designed to simplify installations, with features such as plug in designs, instant feedback messages to ensure correct installation of individual devices, and field-selectable candela settings. When installing the P2RHK-120, first attach the 120V mounting plate to the outdoor back box provided with each unit. Next, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. Finally, attach the horn/strobe to the mounting plate by inserting the product’s tabs in the mounting plate’s grooves. The device will rotate into position, locking the product’s pins into the mounting plate’s terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. The SpectrAlert Advance series outdoor notification appliances are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. P2RHK-120 Outdoor 120V Selectable Output Horn/Strobe The SpectrAlert® Advance selectable-output outdoor 120V horn/strobe is rich with features guaranteed to cut installation times and maximize profits. MEA452-05-E 7300-1653:187 (outdoor strobes) 7125-1653:188 (horn/strobes S4011S5512S3593 3825 Ohio Avenue •St.Charles,IL 60174 Phone:800-SENSOR2 •Fax:630-377-6495 ©2012SystemSensor. Productspecificationssubject tochangewithout notice.Visitsystemsensor.comforcurrentproductinformation,including thelatestversionof thisdatasheet.AVDS01700 •03/12 P2RHK-120 Dimensions Model Description P2RHK-120*2-wire Horn/Strobe, High cd, Red, Outdoor, 120VAC SpectrAlert Advance Ordering Information Notes: *Includes P2RHK 2-wire horn/strobe, MP120K 120VAC adapter mounting plate, and weatherproof back box. “High cd,” refers to strobes that include 135, 150, 177, and 185 candela settings. All outdoor units ending in “K” include a weatherproof back box. 4.7˝ 5.6˝ 6.8˝Dia. 2.5˝ 2.5˝ 2.23˝5.05˝ 5.98˝ 7.1˝Dia. 2.25˝ 5.1˝ 2.0˝ 5.7˝ 7.1˝Dia. 2.0˝ Wall-mount horn/strobes Wall weatherproof back box P2RHK-120 Mounting SpectrAlert Advance Specifications Architect/Engineer Specifications The horn/strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn/strobe models shall operate on a coded or non-coded power supply. Outdoor Products SpectrAlert Advance outdoor horn/strobe shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit. The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries. Physical/Electrical Specifications Operating Temperature –40°F to 151°F (–40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 120VAC Operating Voltage Range 96 – 132VAC Input terminal wire gauge 12 to 18 AWG Dimensions 5.7˝L × 5.1˝W × 2.0˝D (145 mm L × 130 mm W × 51 mm D) Candela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Strobe Output (cd) Listed Candela Candela rating at –40°F 135 135 150 150 177 177 185 185 120V MOUNTING PLATE MP120K OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 90 www.tolco.com Revision 3/1/2007 Fig. 200 - “Trimline” Adjustable Band Hanger Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil. Galvanized to G90 specifications Function — For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features — • (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. • (21⁄2" thru 8") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals — Underwriters’ Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature — 650°F Finish — Mil. Galvanized. For Stainless Steel materi- als, order TOLCO™ Fig. 200WON. Order By — Figure number and pipe size Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Wt./100 1/2 3/8 8mm or 10mm 31⁄8 25⁄8 400 11 3/4 3/8 8mm or 10mm 31⁄8 21⁄2 400 11 1 3/8 8mm or 10mm 33⁄8 25⁄8 400 12 11⁄4 3/8 8mm or 10mm 33⁄4 27⁄8 400 13 11⁄2 3/8 8mm or 10mm 37⁄8 27⁄8 400 14 2 3/8 8mm or 10mm 41⁄2 3 400 15 21⁄2 3/8 10mm 55⁄8 41⁄8 600 27 3 3/8 10mm 57⁄8 4 600 29 31⁄2 3/8 10mm 73⁄8 51⁄4 600 34 4 3/8 10mm 73⁄8 5 1000 35 5 1/2 12mm 91⁄8 61⁄4 1250 66 6 1/2 12mm 101⁄8 63⁄4 1250 73 8 1/2 12mm 131⁄8 83⁄4 1250 136 Office/Manufacturing Facility •1375 Sampson Ave. •Corona, CA 92879 •Ph: 951.737.5599 •Fax: 951.737.0330 Customer Service •800.786.5266 www.tolco.com 72 www.tolco.com Revision 5/24/2001 ™ ®a brand of Fig. 98 - Rod Stiffener Size Range — Secures 3/8" thru 7/8" hanger rod Material — Carbon Steel Function — Secures channel to hanger rod for vertical seismic bracing. Finish — Electro Galvanized Note — Available in HDG finish or Stainless Steel materials. Order By — Figure number Fig. 99 - All Thread Rod Cut to Length Size Range — Secures 3/8" thru 7/8" rod in 1" increments Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter, rod length and finish Fig. 100 - All Thread Rod Full Lengths Size Range — Secures 3/8" thru 7/8" rod in 10’ lengths Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter and finish Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 11/2 11630 10370 510 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 62 www.tolco.com Revision 1/24/2007 Size Range — 3/8" thru 3/4" rod Function — For attachment to structural shapes requiring wider throat especially under roof with bar joist construction. This clamp may be used in the set screw down position only. Approvals — Conforms to Federal Specification WW-H-171E, Type 23 and Manufacturers Standardization Society SP-69, Type 19. Finish — Plain Note — Available in Electro-Galvanized finish. Order By — Figure number, rod size and finish Note — Do not over tighten set screw. Fig. 68 - Wide Throat Top Beam “C” Clamp w/Locknut Dimensions • Weights Rod Max. Rec. Approx. Size Load Lbs. Wt./100 3/8 400 34 1/2 500 50 5/8 600 53 3/4 800 86 NFPA SIDEWINDERS™ Sammy Swivel Head™ NEW! NEW! NEW! NEW! NEW! NEW! NEW! NEW! NEW! NEW! * Use with 3/8” U.S. Patent No. 6,443,680 • Most Items Available in Stainless Steel SAMMY X-PRESS™Patent Pending Uninstalled Installed TM HORIZONTAL Mount Approvals Part # Item # Model Screw Descriptions Box Qty. Weight (per 125) Case Qty 8139957 4702 SH-GST 20 1/4 x 2 25 9.38 125 8140957 4703 SH-GST 22SS 1/4 x 2 25 9.38 125 8141957 4704 SH-GST 30 1/4 x 3 25 10.94 125 8142957 4705 SH-GST 30SS 1/4 x 3 25 10.94 125 8137957 4700 SH-DSTR 1 1/4-20 x 1 25 9.38 125 8138957 4701 SH-DSTR 1 - SS 1/4-20 x 1 25 9.38 125 WOOD STEEL Approvals Rod Size Part # Item # Model Screw Descriptions Box Qty. Weight (per 125) Case Qty 1/4" 8062957 1900 SWC 200 5/16 X 1-1/2 25 9.38 125 3/8" 8061957 65 SWC 20 5/16 X 1-1/2 25 9.38 125 Approvals Rod Size Part # Item # Model Screw Descriptions Box Qty. Weight (per 125) Case Qty 3/8" 8050957 39 SWD 10 1/4-14 X 1 25 7.50 125 3/8" 8051957 40 SWD 15 1/4-14 X 1-1/2 25 9.38 125 3/8" 8052957 41 SWD 20 1/4-14 X 2 25 8.13 125 3/8" 8053957 42 SWD 516 5/16-18 X 1-1/4 25 8.75 125 3/8" 8054957 46 SWDR 1-1/2" 1/4-20 X 1-1/2 25 9.06 125 3/8" 8055957 43 SWDR 1" 1/4-20 X 1 25 8.75 125 3/8" 8056957 44 SWDR 516 5/16-18 X 1-1/4 25 10.31 125 3/8" 8057957 45 SWT 15 12-24 X 1-1/2 25 7.81 125 Approvals Rod Size Part # Item # Model Screw Descriptions Box Qty. Weight (per 125) Case Qty 1/4" 8018957 4016 SWG 100 1/4 X 1 25 9.38 125 1/4" 8019957 300 SWG 200 1/4 X 2 25 10.00 125 3/8" 8020957 18 SWG 10 1/4 X 1 25 7.50 125 3/8" 8021957 19 SWG 20 1/4 X 2 25 8.75 125 3/8" 8022925 26 SWG 25-380 3/8 X 2-1/2 25 12.81 125 3/8" 8023925 25 SWG 30 1/4 X 3 25 10.63 125 Approvals Steel Ga.Part # Item # Model Box Qty. Weight (per 125) Case Qty. 22-20 8150922 500 XP 20 25 10.3 125 18-16 8153922 503 XP 35 25 10.3 125 8151910 501 XPIT 1 1.02 1 8152910 502 XPDB 1 0.14 1 Sammy X-Press It Installation Tool 25/64" Drill Bit Screw Descriptions 1/4-20 x 1-1/8 Sammy X-Press 20 (Kit includes: Sleeve, Bit Receiver, Hex Wrench, and 25/64" Drill Bit) STEEL 1/4-20 x 1-1/8 Sammy X-Press 35 • 17° deflection from vertical • Accommodates up to 3-1/2 x 12 pitch roof • Also available in stainless steel • Use #14 Nut Driver (black) Hang Threaded R o d D i r e c t l y from Thin Gaug e M e t a l Deck & Purlin Steel Concrete Wood Part # 8114910 Item # 101 Nut Driver Use #14SW Nut Driver for Sidewinders and 1/2” Rod Sammys