HomeMy WebLinkAboutF16-0031_FP3_1478903096.pdf47 heads for Unit B
18 heads for lower level
17 heads for main level
12 heads for upper level
This system as shown on company print no dated
for at
contract no is designed to discharge at a rate of
a maximum area of when supplied with water at a rate of
Occupancy classification:
Commodity classification:
Maximum storage height:
Storage arrangement:
Number of heads flowing:
System Type:
Maximum velocity:
Flow from In-Rack sprinklers:
Flow from Overhead sprinklers:
Flow from Inside Hoses:
Flow from Outside Hoses:
Other fixed flows:
Total flow in system piping:
Additional flow at/beyond source:
Total of all flows:
Calculation results for Design Area
JSPIWð /PLQPð RI IORRU DUHD RYHU
-
Surplus Pressure at Source:
Pressure Required at Source:
Pressure Available at Source:
at
at the base of the riser.
Hose stream allowance of is included in the above.
2 Unit B Living/Dining
Gore Creek Res Beaver Dam Rd
0.1
IWð 94.8 gpm
92.3 psi
Res
4
Wet
23.24 ft/s
0 gpm
94.8 gpm
0 gpm
0 gpm
0 gpm
94.8 gpm
0 gpm
94.8 gpm
92.3 psi
114.9 psi
22.6 psi
DA Name: 2
DA Area: 409.63
1 1/2" / 12"
MASTER
BEDROOM
106
MASTER
BATHROOM
107
W.C.
108
MASTER CLOSET
109
POWDER
110
UNIT B LAUNDRY
111
ELEVATOR
105
KITCHEN
101
DINING ROOM
102
LIVING ROOM
103
UNIT A GARAGE
125
UNIT
122
W.C.
PANTRY
104
BROOM / LINEN
128
UNIT B STORAGE
126
B.O. DECKING @ 13' - 1 3/4" A.F.F.
B.O. DECKING @ 13' - 5 1/2" A.F.F.
B.O. GWB @ 9' - 0" A.F.F.
B.O. DECKING @ 15' - 9 1/2" A.F.F.
B.O. GWB @ 9' - 6" A.F.F.
1 1/2" / 12"
B.O. GWB @ 10' - 5 5/8" A.F.F.
B.O. GWB @ 8' - 6" A.F.F.
B.O. GWB @ 8' - 6" A.F.F.
B.O. GWB @ 8' - 6" A.F.F.
B.O. GWB @ 8' - 6" A.F.F.
B.O. DECKING @ 13' - 11 3/4" A.F.F.
B.O. DECKING @ 15' - 7 3/8" A.F.F.
B.O. GWB @ 11' - 9 1/8" A.F.F.
B.O. GWB @ 10' - 5 5/8" A.F.F.
B.O. GWB @ 9' - 6"
SHOWER
1A
2A
B
C
D
E
F
G
H
I
J
K
AA
BB
CC
BBB
AAA
stairs open to
above
6 16 16
5151 Bannock St.
Denver, CO
80216
303-291-1012
303-383-5023 FAX
firesprinkler@afssco.com
A FIRE SPRINKLER
DESIGN COMPANY
ACCEPTING THIS COPY IS DEEMED AS AGREEING TO THE FOLLOWING: THIS DRAWING COPY, ITS CONTENTS,
INFORMATION AND PRINCIPALS OF DESIGN ARE THE EXCLUSIVE PROPERTY OF THE FIRE PROTECTION
CONTRACTOR LISTED AND MILE HIGH DESIGN GROUP, LLC AND IS BEING SUBMITTED TO YOU WITH THE
UNDERSTANDING THAT IT IS NOT TO BE REPRODUCED, COPIED OR MODIFIED IN ANY MANNER; NEITHER SHALL
IT BE RELAYED IN WHOLE OR IN PART TO ANY OTHER INDIVIDUAL OR FIRM FOR ANY OTHER PROJECT OR
EXTENSION OF THIS PROJECT EXCEPT THRU WRITTEN AGREEMENT WITH THE FIRE PROTECTION CONTRACTOR
AND MILE HIGH DESIGN GROUP, LLC. ERRORS AS A RESULT OF THIS FILE BEING ELECTRONICALLY
TRANSMITTED ARE BEYOND THE CONTROL OF AND ARE NOT THE RESPONSIBILITY OF THE FIRE PROTECTION
CONTRACTOR OR MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR
INSTALLATION OR INSPECTION OF WORK INSTALLED. THESE PLANS ARE DIAGRAMMATICAL ONLY. ON SITE
COORDINATION MUST BE ARRANGED WITH ALL OBSTRUCTIONS, i.e.: MECHANICAL, ELECTRICAL, AND
STRUCTURAL. ANY ALTERATIONS FROM ENGINEERED DRAWINGS MUST BE APPROVED BY MILE HIGH DESIGN
GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR LAYOUT DESIGN ISSUES OR CONFLICTS WITH
ANY OBSTRUCTIONS. IF ADDITIONAL FIRE SPRINKLER PIPING AND/OR FIRE SPRINKLER HEADS ARE REQUIRED
THIS WILL BE THE RESPONSIBILITY OF THE FIRE SPRINKLER CONTRACTOR. ALL CHANGES MUST ME APPROVED
BY MILE HIGH DESIGN GROUP, LLC
THE OWNER IS RESPONSIBLE TO PROVIDE SUFFICIENT HEAT THROUGHOUT THIS BUILDING TO PREVENT
FREEZING OF WATER IN THE FIRE SPRINKLER SYSTEM -
SCALE: 1/4" = 1'-0"
PLAN
NORTH
FIRE SPRINKLER PLANS
1 2 3 4 5 6 7 8 9 10
MAIN LEVEL
Vail Fire & Emergency Services
06/28/16