HomeMy WebLinkAboutF16-0031_FP4_1478903099.pdf47 heads for Unit B
18 heads for lower level
17 heads for main level
12 heads for upper level
This system as shown on company print no dated
for at
contract no is designed to discharge at a rate of
a maximum area of when supplied with water at a rate of
Occupancy classification:
Commodity classification:
Maximum storage height:
Storage arrangement:
Number of heads flowing:
System Type:
Maximum velocity:
Flow from In-Rack sprinklers:
Flow from Overhead sprinklers:
Flow from Inside Hoses:
Flow from Outside Hoses:
Other fixed flows:
Total flow in system piping:
Additional flow at/beyond source:
Total of all flows:
Calculation results for Design Area
JSPIWð /PLQPð RI IORRU DUHD RYHU
-
Surplus Pressure at Source:
Pressure Required at Source:
Pressure Available at Source:
at
at the base of the riser.
Hose stream allowance of is included in the above.
1 Unit B Garage
Gore Creek Res Beaver Dam Rd
0.1
IWð 82.6 gpm
98.8 psi
Res
4
Wet
20.24 ft/s
0 gpm
82.6 gpm
0 gpm
0 gpm
0 gpm
82.6 gpm
0 gpm
82.6 gpm
98.8 psi
114.9 psi
16.1 psi
DA Name: 1
DA Area: 566.11
1 1/2" / 12"
1 1/2" / 12"
1 1/2" / 12"
B.O. DECKING @ 10' - 2 1/2" A.F.F.
B.O. DECKING @ 12' - 1 1/2" A.F.F.
1 1/2" / 12"
B.O. GWB @ 8' - 6" A.F.F.
B.O. GWB @ 8' - 6" A.F.F.
B.O. GWB @ 9' - 6" A.F.F.
1 1/2" / 12"
B.O. GWB @ 12' - 11 3/4" A.F.F.
B.O. GWB @ 11' - 4 7/8" A.F.F.
BEDROOM #2
203
BATHROOM #2
205 W.C.
206
CLOSET #2
204
ELEVATOR
202
UNIT B ENTRY
201
UNIT B MUD
ROOM
207
UNIT B GARAGE
208
UNIT A
BATHROOM #3
216
W.C.
217
CLOSET #3
215
BEDROOM #3
214
ELEVATOR
209
B.O. GWB @ 10' - 2 1/2" A.F.F.
B.O. GWB @ 8' - 10 1/8" A.F.F.
B.O. GWB @ 8' - 6" A.F.F.
B.O. GWB @ 8' - 6" A.F.F.
B.O. GWB @ 9' - 6" A.F.F.
B.O. GWB @ 9' - 6" A.F.F.
B.O. GWB @ 9' - 6" A.F.F.
1 1/2" / 12"
B.O. GWB @ 11' - 4 7/8" A.F.F.
B.O. GWB @ -0' - 2 1/4" A.F.F.
B.O. GWB @ 10' - 0" A.F.F.
1A
2A
E
F
G
H
I
J
K
AA
BB
CC
BBB
AAA
CCC
2B
ELECTRIC METER
LOCATION
MDP LOCATION
CT CAB LOCATION
J-BOX
J-BOX
J-BOX
J-BOX
FAN
FAN
FAN
CLG
FAN
SOLAR
WP
BLACKOUT
6 16 16
5151 Bannock St.
Denver, CO
80216
303-291-1012
303-383-5023 FAX
firesprinkler@afssco.com
A FIRE SPRINKLER
DESIGN COMPANY
ACCEPTING THIS COPY IS DEEMED AS AGREEING TO THE FOLLOWING: THIS DRAWING COPY, ITS CONTENTS,
INFORMATION AND PRINCIPALS OF DESIGN ARE THE EXCLUSIVE PROPERTY OF THE FIRE PROTECTION
CONTRACTOR LISTED AND MILE HIGH DESIGN GROUP, LLC AND IS BEING SUBMITTED TO YOU WITH THE
UNDERSTANDING THAT IT IS NOT TO BE REPRODUCED, COPIED OR MODIFIED IN ANY MANNER; NEITHER SHALL
IT BE RELAYED IN WHOLE OR IN PART TO ANY OTHER INDIVIDUAL OR FIRM FOR ANY OTHER PROJECT OR
EXTENSION OF THIS PROJECT EXCEPT THRU WRITTEN AGREEMENT WITH THE FIRE PROTECTION CONTRACTOR
AND MILE HIGH DESIGN GROUP, LLC. ERRORS AS A RESULT OF THIS FILE BEING ELECTRONICALLY
TRANSMITTED ARE BEYOND THE CONTROL OF AND ARE NOT THE RESPONSIBILITY OF THE FIRE PROTECTION
CONTRACTOR OR MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR
INSTALLATION OR INSPECTION OF WORK INSTALLED. THESE PLANS ARE DIAGRAMMATICAL ONLY. ON SITE
COORDINATION MUST BE ARRANGED WITH ALL OBSTRUCTIONS, i.e.: MECHANICAL, ELECTRICAL, AND
STRUCTURAL. ANY ALTERATIONS FROM ENGINEERED DRAWINGS MUST BE APPROVED BY MILE HIGH DESIGN
GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR LAYOUT DESIGN ISSUES OR CONFLICTS WITH
ANY OBSTRUCTIONS. IF ADDITIONAL FIRE SPRINKLER PIPING AND/OR FIRE SPRINKLER HEADS ARE REQUIRED
THIS WILL BE THE RESPONSIBILITY OF THE FIRE SPRINKLER CONTRACTOR. ALL CHANGES MUST ME APPROVED
BY MILE HIGH DESIGN GROUP, LLC
THE OWNER IS RESPONSIBLE TO PROVIDE SUFFICIENT HEAT THROUGHOUT THIS BUILDING TO PREVENT
FREEZING OF WATER IN THE FIRE SPRINKLER SYSTEM -
SCALE: 1/4" = 1'-0"
PLAN
NORTH
FIRE SPRINKLER PLANS
1 2 3 4 5 6 7 8 9 10
UPPER LEVEL
Vail Fire & Emergency Services
06/28/16