Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Equipment Data Sheets.pdf
AUTOMATIC FIRE SPRINKLER SYSTEM EQUIPMENT SUBMITTAL FOR VAIL VALLEY MEDICAL CENTER 180 SOUTH FRONTAGE ROAD VAIL, CO 81657 PHASE 1 RENOVATION WEST WING TEMPORARY PROTECTION FOR LEVEL 1 PHASE C REMODEL AREA microfast® and microfastHP® quick resPonse uPrigHt and conventional sPrinklers tecHnical data December 4, 2013 the viking corporation, 210 n industrial Park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com 1. descriPtion Viking Microfast® and MicrofastHP® Quick Response Upright and Conventional (Old Style) Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes, temperature ratings, and K-Factors to meet design require- ments. The special Polyester, Polytetrafluoroethylene (PTFE), and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmos-pheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: fm global approves the ent coating as corrosion resistant. FM Global has no approval classification for PTFE and Polyester coatings as corrosion resistant.) 2. listings and aPProvals culus listed: Category VNIV fm approved: Classes 2002 and 2020 nYc approved: Calendar Number 219-76-SA and MEA 89-92-E, Volume 16 aBs certified: Certificate 04-HS407984B-PDA vds approved: Certificates G4060054, G4060056, G4880046, G4930039, and G4980020 lPc approved: Ref. No. 096e/03, TE30401, and TE30872 ce certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40131, 0786-CPD-40171, and 0786-CPD-40278 med certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 note: Other International approval certificates are available upon request. Refer to Approval Chart 1 and Design Criteria on pages 51c-d for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 51e for FM Approval requirements that must be followed. 3. tecHnical data specifications: Available since 1987.Minimum Operating Pressure: 7 psi (0.5 bar)* maximum Working Pressure: sprinklers vk315 and vk340 are rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating “250” stamped on the de-flector. all other Part nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Charts Nominal K-Factor: Refer to the Approval Charts Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Charts *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). material standards: Frame Casting: Brass UNS-C84400 or QM Brass for Sprinklers 12978, 06766B, 07060, and 12281. Brass UNS-C84400 for all other sprinklers. Deflector: Brass UNS-C23000 or Copper UNS-C19500 for Sprinklers 12978, 06764B, and 12281. Copper UNS-C19500 for Sprinklers 06665B, 07060, and 14817. Brass UNS-C26000 for all other Sprinklers.Bushing (for Sprinklers 06719B, 06717B, and 12286): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Form No. F_080488 viking technical data may be found on the viking corporation’s Web site at http://www.vikinggroupinc.com. the Web site may include a more recent edition of this technical data Page. Sprinkler 51a Replaces page 51a-e, dated June 28, 2013. (Changed 06931 to VK3271) tecHnical data December 4, 2013 the viking corporation, 210 n industrial Park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com microfast® and microfastHP® quick resPonse uPrigHt and conventional sPrinklers Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE TapeScrew: Brass UNS-C36000Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE CoatedFor Polyester Coated Sprinklers: Belleville Spring-ExposedFor ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated.ordering information: (Also refer to the current Viking price list.)Order Microfast® and MicrofastHP® Quick Response Upright and Conventional Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and Black PTFE = N, ENT = JNTemperature Suffix (°F/°C): 135°/57° = A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141° = GFor example, sprinkler VK300 with a 1/2” thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 12978AB available finishes and temperature ratings: Refer to Table 1. accessories: (Also refer to the “Sprinkler Accessories” section of the Viking data book.) sprinkler Wrench: Standard Wrench: Part No. 10896W/B (available since 2000) sprinkler cabinets:A. Six-head capacity: Part No. 01724A (available since 1971)B. Twelve-head capacity: Part No. 01725A (available since 1971) 4. installationRefer to appropriate NFPA Installation Standards. 5. oPeration During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. insPections, tests and maintenanceRefer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. availaBilitY The Viking Microfast® and MicrofastHP® Quick Response Upright and Conventional Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. guaranteeFor details of warranty, refer to Viking’s current list price schedule or contact Viking directly. Sprinkler 51b taBle 1: availaBle sPrinkler temPerature ratings and finisHes sprinkler temperature classification sprinkler nominal temperature rating1 maximum ambient ceiling temperature2 Bulb color Ordinary 135 °F (57 °C)100 °F (38 °C)Orange Ordinary 155 °F (68 °C)100 °F (38 °C)Red Intermediate 175 °F (79 °C)150 °F (65 °C)Yellow Intermediate 200 °F (93 °C)150 °F (65 °C)Green High 286 °F (141 °C)225 °F (107 °C)Blue sprinkler finishes: Brass, Chrome, White Polyester, Black Polyester, Black PTFE, and ENT corrosion-resistant coatings3: White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 °C) footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards.3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 51c-e. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For ENT coated automatic sprinklers, the waterway is coated. microfast® and microfastHP® quick resPonse uPrigHt and conventional sPrinklers tecHnical data December 4, 2013 the viking corporation, 210 n industrial Park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com approval chart 1 (ul) microfast® and microfastHP® quick response upright and conventional sprinklers maximum 175 Psi (12 bar) WWP Base Part number1 sin thread size nominal k-factor overall length listings and approvals3 (refer also to design criteria on page 51d.) nPt BsP u.s.metric2 inches mm culus4 nYc8 vds lPcB upright-standard orifice 12978 VK300 1/2”15 mm 5.6 80.6 2-3/16 56 A1, B4 See Footnote 7.-------- 07060 VK345 --15 mm 5.6 80.6 2-3/16 56 ----A2 A2 B212 B215 conventional-standard orifice 06766B VK310 1/2”15 mm 5.6 80.6 2-3/16 56 A2 A2 --A2 B212 B215 upright-large orifice 06665B VK350 3/4”--8.0 115.2 2-5/16 59 A1, B4 A1 A2 A2 B212 -- 14817 VK350 --20 mm 8.0 115.2 2-5/16 59 A1, B4 A1 A2 A2 B212 -- 06764B16 VK350 1/2”15 mm 8.0 115.2 2-5/16 59 A1, B4 A1 A2 --A213 -- conventional-large orifice 06768B VK354 3/4”20 mm 8.0 115.2 2-5/16 59 A1 A2 --A2 B212 -- upright-small orifice11 06717B11 VK325 1/2”15 mm 2.8 40.3 2-3/16 56 A1 A1 -------- 06719B11 VK327 1/2”15 mm 4.2 57 2-3/16 56 A1 A1 -------- 06931B11 VK3271 --10 mm 4.2 57 2-3/16 56 ----A2 --C314 -- maximum 250 Psi (17 bar) WWP upright-standard orifice Base Part number1 sin thread size nominal k-factor overall length listings and approvals3 (refer also to design criteria on page 51d.) nPt BsP u.s.metric2 inches mm culus4 nYc9 vds lPcB 12281 VK315 1/2”15 mm 5.6 80.6 2-3/16 56 A1 A1 -------- upright-small orifice10 1228611 VK340 1/2”15 mm 2.8 40.3 2-3/16 56 A1 A1 -------- approved temperature ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) C - 155 °F (68 °C) approved finishes 1 - Brass, Chrome, White Polyester5,6, Black Polyester5,6, and Black PTFE5 2 - Brass, Chrome, White Polyester5,6, and Black Polyester5,6 3 - Brass and Chrome 4 - ENT5 footnotes 1 Base part number is shown. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 cULus Listed as corrosion resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. 7 Meets New York City requirements, effective July 1, 2008. 8 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. 9 Accepted for use, City of New York Department of Buildings, MEA 89-92-E, Vol. 16. 10 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. 11The sprinkler orifice is bushed. 12 Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. 13 Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40278. 14 Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40131. 15 MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. 16 The 1/2” NPT Large Orifice Sprinkler is Listed and Approved for retrofit only Sprinkler 51c tecHnical data December 4, 2013 the viking corporation, 210 n industrial Park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com microfast® and microfastHP® quick resPonse uPrigHt and conventional sPrinklers Sprinkler 51d figure 1: standard sprinkler Wrench 10896W/B design criteria - ul (Also refer to Approval Chart 1 on page 51c) culus listing requirements: Microfast® and MicrofastHP® Quick Response Upright and Conventional Sprinklers are cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers, or old style (conventional) sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. For conventional sprinklers, refer to the installation guidelines for old style (conventional) sprinklers. • • imPortant: always refer to Bulletin form no. f_091699 - care and Handling of sprinklers. also refer to page qr1-3 for general care, installation, and maintenance information. viking sprinklers are to be installed in accor- dance with the latest edition of viking technical data, the appropriate standards of nfPa, lPcB, aPsad, vds or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. microfast® and microfastHP® quick resPonse uPrigHt and conventional sPrinklers tecHnical data December 4, 2013 the viking corporation, 210 n industrial Park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs@vikingcorp.com Sprinkler 51e design criteria - fm (Also refer to Approval Chart 2 above.) fm approval requirements: The sprinklers indicated in Approval Chart 2 are FM Approved as quick response non-storage upright sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. note: the fm installation guidelines may differ from culus and/or nfPa criteria. imPortant: always refer to Bulletin form no. f_091699 - care and Handling of sprinklers. also refer to page qr1-3 for general care, installation, and maintenance information. viking sprinklers are to be installed in ac- cordance with the latest edition of viking technical data, the appropriate standards of nfPa, fm global, lPcB, aPsad, vds or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. approval chart 2 (fm) microfast® quick response upright sprinklers maximum 175 Psi (12 bar) WWP Base Part number1 sin thread size nominal k-factor overall length fm approvals3 (refer also to design criteria below.)nPt BsP u.s.metric2 inches mm standard orifice 12978 VK300 1/2”15 mm 5.6 80.6 2-3/16 56 A2, B3 07060 VK345 --15 mm 5.6 80.6 2-3/16 56 A2 large orifice 06665B VK350 3/4”--8.0 115.2 2-5/16 59 A2, B3 14817 VK350 --20 mm 8.0 115.2 2-5/16 59 A2, B3 06764B7 VK350 1/2”15 mm 8.0 115.2 2-5/16 59 A2, B3 small orifice4 06717B6 VK325 1/2”15 mm 2.8 40.3 2-3/16 56 A1 approved temperature ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) approved finishes 1 - Brass and Chrome 2 - Brass, Chrome, White Polyester5, and Black Polyester5 3 - ENT8 footnotes 1 Base part number is shown. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4 FM Approved as quick response non-storage pendent sprinklers. For specific application and installation requirements, reference the latest appli- cable FM Loss Prevention Data Sheets (including Data Sheet 2-0). 5 Other colors are available on request with the same Approvals as the standard colors. 6 The sprinkler orifice is bushed. 7 The 1/2” NPT Large Orifice Sprinkler is Listed and Approved for retrofit only 8 FM approved as corrosion resistant. MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6)TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Form No. F_033314 16.01.28 Rev 16.1 Page 1 of 6 1. DESCRIPTION The Viking Microfast® Quick Response Pendent Sprinkler VK302 is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester, Polytetrafluoroethelyne (PTFE), and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves ENT finish as corrosion resistant. FM Global has no approval classification for PTFE and Polyester coatings as corro- sion resistant.) 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class Series 2000 VdS Approved: Certificates G414009 and G414010 LPCB Approved CE Certified: Standard EN 12259-1:1999, A3:2006 Certificate of Constancy of Performance 0832-CPR-S0021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressureFactory tested hydrostatically to 500 psi (34.5 bar)Thread size: 1/2” NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4” (58 mm) *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-C51000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, Black PTFE = N, and ENT = JN Temperature Suffix: 135 °F (57 °C) = A, 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G For example, sprinkler VK302 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12979AB Viking Technical Data may be found on The Viking Corporation’s Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Replaces Form F_033314 Rev 15.2 (Revised temperature suffix designation) MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6)TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Form No. F_033314 16.01.28 Rev 16.1 Page 2 of 6 Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the “Sprinkler Accessories” section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 10896W/B (available since 2000). B. Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006)C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A ½” ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1” diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A (available since 1971)B. Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATIONRefer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCERefer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfast® Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis-tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. Figure 1: Standard Sprinkler Wrench 10896W/B Protective Sprinkler Cap Wrench FlatProtective Sprinkler Clip MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6)TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Form No. F_033314 16.01.28 Rev 16.1 Page 3 of 6 TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating1 Maximum Ambient Ceiling Temperature2 Bulb Color Ordinary 135 °F (57 °C)100 °F (38 °C)Orange Ordinary 155 °F (68 °C)100 °F (38 °C)Red Intermediate 175 °F (79 °C)150 °F (65 °C)Yellow Intermediate 200 °F (93 °C)150 °F (65 °C)Green High 286 °F (141 °C)225 °F (107 °C)Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, Black PTFE, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 °C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, PTFE, and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Sprinkler wrench 13655W/B** for recessed pendent sprinklers ** A 1/2” ratchet is required (not available from Viking) MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6)TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Form No. F_033314 16.01.28 Rev 16.1 Page 4 of 6 Approval Chart 1 (UL)The Viking Microfast® Quick Response Pendent Sprinkler VK302 Maximum 175 PSI (12 Bar) WWP Base Part Number1 SIN Sprinkler Style Thread Size Nominal K-Factor Overall Length Listings and Approvals3 (Refer also to Design Criteria.) NPT BSP U.S.metric2 Inches mm cULus4 VdS LPCB 7 12979 VK302 Pendent 1/2”15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X A1 A1Z, B1Y D1Z, C1Y --D3Z NOTICE - Product Below - Limited Availability (Contact Local Viking Office) 06662B VK302 Pendent 1/2”15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X ---------- 18021 VK302 Pendent 1/2”15 mm 5.6 80.6 2-1/4 58 A1X, B1Y A1 A1X, B1Y D1X, C1Y8 D1X, C1Y9 -- Approved Temperature Ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C)B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C)C - 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) D - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C) Approved Finishes 1 - Brass, Chrome, White Polyester5,6, Black Polyes-ter5,6 2 - ENT5 3 - Chrome Approved Escutcheons X - Standard surface-mounted escutcheon or the Viking Micromatic® Model E-1 Recessed EscutcheonY - Standard surface-mounted escutcheon or the Viking Microfast® Model F-1 Adjustable Escutcheon, or recessed with the Viking Micro-matic® Model E-1, E-2, or E-3 Recessed EscutcheonZ - Standard surface-mounted escutcheon or the Viking Microfast® Model F-1 Adjustable Escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. 7 CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001. 8 CE Certified, Standard EN 12259-1, EC-certificates of conformity 0832-CPD-2001 and 0832-CPD-2003.9 MED Certified, Standard EN 12259-1, EC-certificates of conformity 0832-MED-1003 and 0832-MED-1008. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6)TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Form No. F_033314 16.01.28 Rev 16.1 Page 5 of 6 Approval Chart 2 (FM)The Viking Microfast® Quick Response Pendent Sprinkler VK302 Maximum 175 PSI (12 Bar) WWP Base Part Number1 SIN Sprinkler Style Thread Size Nominal K-Factor Overall Length FM Approvals3 (Refer also to Design Criteria.)NPT BSP U.S.metric2 Inches mm 12979 VK302 Pendent 1/2”15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 NOTICE - Product Below - Limited Availability (Contact Local Viking Office) 06662B VK302 Pendent 1/2”15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 18021 VK302 Pendent 1/2”15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y Approved Temperature Ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C) B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C) D - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C) Approved Finishes 1 - Brass, Chrome, White Polyester4, and Black Polyester4 2 - ENT5 Approved Escutcheons X - Standard surface-mounted escutcheon or the Viking Micromatic® Model E-1 Recessed Escutcheon Y - Standard surface-mounted escutcheon or the Viking Microfast® Model F-1 Adjustable Escutcheon, or recessed with the Viking Micromatic® Model E-1 or E-2 Recessed Escutcheon Z - Standard surface-mounted escutcheon or the Viking Microfast® Model F-1 Adjustable Escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing. Other approvals may be in process. 4 Other colors are available on request with the same Approvals as the standard colors. 5 FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage upright and pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6)TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Form No. F_033314 16.01.28 Rev 16.1 Page 6 of 6 Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon 1/2” (15 mm) NPT 2-1/4” (57 mm)1-3/4” (44.5 mm) 2” (51 mm)Max. 2-1/8” (54 mm) 1-1/2” (38 mm)Min. Installed with a standard 1/8” surface-mounted escutcheon Installed with a Microfast Model F-1 Adjustable Escutcheon Ceiling Opening Size: 2-5/16” (58.7 mm) minimum 2-1/2” (63.5 mm) maximum Note: At maximum, adapter is exposed 1/2” (12.7 mm) from face of ceiling 1-3/4” (44.5 mm)Max. 2-1/8” (54 mm) 1-1/8” (28.6 mm)Min. 2”” (51 mm)Max. 1-1/8” (28.6 mm)Min. 2-1/8” (54 mm) Ceiling Opening Size: 2-5-16” (58.7 mm) minimum 2-1/2” (63.5 mm) maximum Installed with a Model E-1 Recessed Escutcheon Installed with a Model E-2 Thread-on Recessed Escutcheon Replaces Form F_0333314 Rev 15.2 (Revised temperature suffix designation) Wheatland Tube Company 900 Haddon Avenue Collingswood, NJ 08108-2162 800.257.8182 www.wheatland.comWheatland ASTM A 53 Schedule 40 Pipe Wheatland Steel Pipe is made by specialists who understand that it’s the small details that make the difference between average products and superior products. At the Wheatland Plant, most department heads and foremen have been employed in some phase of pipe manufacturing for 25 or more years. This kind of specialization, experience and knowledge pays off...in workable, threadable, uniform pipe. Delivered clean. Delivered promptly. Wheatland specializes in manufacturing welded steel pipe in 1/2 through 4 nominal sizes. Available inventory in 1/8 to 12 pipe sizes produced to various ASTM standards is maintained to meet your pipe requirements. Care, pride and personal concern are bonus features that go into every inch of Wheatland Pipe. Don’t settle for less. Make sure it’s quality. Make sure it’s Wheatland. Standard Pipe Schedule 40 Product Type and Specification: Standard welded pipe is produced in 1/2 to 6 trade sizes. Wheatland pipe is produced to ASTM A 53, A 501, and A 589 Type II, API 5L and Federal Specification WW-P404. All pipe threads conform to ANSI B1.20.1. Merchant couplings comply with ASTM A 865. SPN rotangiseD ND rotangiseD edistuO retemaiD edisnI retemaiD llaW ssenkcihT htgneLtinurep)ssaM(thgieWlanimoN )sehcnI()mm()sehcnI()mm()sehcnI()mm(dnEnialP )tf/bl( dnEnialP )m/gk( &sdaerhT sgnilpuoC )tf/bl( &sdaerhT sgnilpuoC m/gk( 8/16 504.03.01962.08.6860.037.142.073.052.073.0 4/18 045.07.31463.02.9880.042.234.036.034.036.0 8/301576.01.71394.05.21190.013.275.048.075.048.0 2/151048.03.12226.08.51901.077.258.072.168.072.1 4/302050.17.62428.09.02311.078.231.196.141.196.1 152513.14.33940.16.62331.083.386.105.296.105.2 4/1-123066.12.24083.11.53041.065.372.293.382.204.3 2/1-104009.13.84016.19.04541.086.327.250.447.240.4 205573.23.06760.25.25451.019.366.344.586.364.5 2/1-256578.20.37964.27.26302.061.508.536.858.576.8 308005.39.88860.39.77612.094.585.792.1186.753.11 2/1-309000.46.101845.31.09622.047.521.975.3172.917.31 4001005.43.411620.43.201732.020.608.0170.6129.0132.61 5521365.53.141740.52.851852.055.636.4177.1209.4170.22 6051526.63.861560.61.451082.011.799.8162.8243.9185.82 8002526.81.912189.77.202223.081.885.8255.2453.9237.34 01052057.010.372020.015.452563.072.925.0492.0694.1463.36 epiPdradnatS 211 003057.218.323000.218.403573.025.916.9487.3782.1512.67 etoN1 .04eludehcston,epipllawdradnatsroferasnoisnemid21SPN Wheatland ASTM A 53 Schedule 40 Pipe SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com78 Ductile Iron Threaded Fittings SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com79 Ductile Iron Threaded Fittings TemperatureDegrees F Working Pressure, Nonshock PsIG300# Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 Specifications • The branded Ductile Iron threaded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 WSP • Ductile Iron castings conform to ASTM A536 • Fitting dimensions conform to ASME B16.3 • Bushings and plugs conform to ASME B16.14 • Fittings are 100% air tested • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical & physical properties • Manufacturing facilities are ISO 9001:2000 and ISO 14001 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com D U C T I l e A A A A A A AA B size IN Part Number a IN Packing Weight LBInnerMaster 1/2 35E 3004 1.13 100 200 0.2 3/4 35E 3006 1.31 70 140 0.3 1 35E 3010 1.50 40 80 0.5 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 size IN Part Number a IN B IN Packing Weight LBInnerMaster 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2 x 1-1/4 35RE3020012 1.90 2.10 12 24 1.3 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 size IN Part Number a IN Packing Weight LBInnerMaster 1/2 35F 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 160 0.3 1 35F 3010 1.13 40 80 0.5 1-1/4 35F 3012 1.29 25 50 0.7 1-1/2 35F 3014 1.44 20 40 1.0 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 size IN Part Number a IN Packing Weight LBInnerMaster 1/2 35T 3004 1.13 80 160 0.3 3/4 35T 3006 1.31 30 60 0.5 1 35T 3010 1.50 25 50 0.7 1-1/4 35T 3012 1.75 10 20 1.1 1-1/2 35T 3014 1.94 10 20 1.5 2 35T 3020 2.25 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 Fig. 35E 3 – 90° Elbow Fig. 35RE3 – 90° Reducing Elbow Fig. 35F 3 – 45° Elbow Fig. 35T 3 – Tee Ductile Iron Fittings - Class 300 UL/FM SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com D U C T I l e A B AB C C size IN Part Number a IN B IN C IN Packing Weight LBInnerMaster 3/4 x 1/2 35RT3006004 1.20 1.20 1.22 60 120 0.4 1 x 1/2 35RT3010004 1.26 1.26 1.36 30 60 0.6 1 x 1/2 x 1 35RT3010004010 1.50 1.36 1.50 30 60 0.6 1 x 3/4 35RT3010006 1.38 1.38 1.45 25 50 0.6 1 x 3/4 x 3/4 35RT3010006006 1.38 1.31 1.45 35 70 0.6 1 x 3/4 x 1 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1-1/4 x 1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4 x 1/2 x 1-1/4 35RT3012004012 1.75 1.53 1.75 25 50 0.9 1-1/4 x 3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 1-1/4 x 3/4 x 1-1/4 35RT3012006012 1.75 1.62 1.75 20 40 1.0 1-1/4 x 1 35RT3012010 1.58 1.58 1.67 15 30 1.0 1-1/4 x 1 x 1/2 35RT3012010004 1.34 1.26 1.53 25 50 0.7 1-1/4 x 1 x 3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4 x 1 x 1 35RT3012010010 1.58 1.50 1.69 20 40 0.9 1-1/4 x 1 x 1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1-1/2 x 1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 1-1/2 x 1/2 x 1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2 x 1/2 x 1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 1-1/2 x 3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2 x 3/4 x 1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 1.1 1-1/2 x 3/4 x 1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 1-1/2 x 1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1-1/2 x 1 x 1/2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 1-1/2 x 1 x 3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1-1/2 x 1 x 1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 1-1/2 x 1 x 1-1/4 35RT3014010012 1.82 1.67 1.88 12 24 1.2 1-1/2 x 1 x 1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 1-1/2 x 1-1/4 35RT3014012 1.82 1.82 1.88 12 24 1.4 1-1/2 x 1-1/4 x 1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 1-1/2 x 1-1/4 x 3/4 35RT3014012006 1.52 1.45 1.75 16 32 1.0 1-1/2 x 1-1/4 x 1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 1-1/2 x 1-1/4 x 1-1/4 35RT3014012012 1.82 1.75 1.88 14 28 1.3 1-1/2 x 1-1/4 x 1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 2 x 1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 2 x 3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 2 x 1 35RT3020010 1.73 1.73 2.02 8 16 1.7 2 x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2 x 1-1/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 2 x 1-1/4 x 2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2 x 1-1/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 2 x 1-1/2 x 1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 2 x 1-1/2 x 3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2 x 1-1/2 x 1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2 x 1-1/2 x 1-1/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2 x 1-1/2 x 1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 size IN Part Number a IN B IN C IN Packing Weight LBInnerMaster 3/4 x 1 35BT3006010 1.45 1.45 1.37 30 60 0.6 1 x 1-1/4 35BT3010012 1.67 1.67 1.58 20 40 0.9 1 x 1-1/2 35BT3010014 1.80 1.80 1.65 15 30 1.0 1-1/4 x 1 x 1-1/2 35BT3012010014 1.88 1.80 1.82 15 30 1.2 1-1/4 x 1-1/2 35BT3012014 1.88 1.88 1.82 15 30 1.3 1-1/4 x 2 35BT3012020 2.10 2.10 1.90 10 20 1.6 1-1/2 x 1-1/4 x 2 35BT3014012020 2.16 2.10 2.02 10 20 1.8 1-1/2 x 2 35BT3014020 2.16 2.16 2.02 8 16 1.8 Fig. 35BT3 – Bull Head Tee Fig. 35RT3 – Reducing Tee Ductile Iron Fittings - Class 300 UL/FM SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com D U C T I l e A A A AA B size IN Part Number a IN Packing Weight LBInnerMaster 1 35U 3010 2.19 20 40 1.0 1-1/4 35U 3012 2.50 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 2 35U 3020 3.12 6 12 2.4 size IN Part Number a IN Packing Weight LBInnerMaster 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 size IN Part Number a IN Packing Weight LBInnerMaster 1 x 1/2 35RC3010004 1.69 80 160 0.3 1 x 3/4 35RC3010006 1.69 60 120 0.4 1-1/4 x 3/4 35RC3012006 2.06 40 80 0.6 2 x 1 (not hex)35RC3020010 2.81 20 40 1.0 size IN Part Number a IN Packing Weight LBInnerMaster 1 x 1/2 35HB3010004 1.06 180 360 0.2 1 x 3/4 35HB3010006 1.06 180 360 0.1 1-1/4 x 1 35HB3012010 1.19 90 180 0.2 1-1/2 x 1 35HB3014010 1.25 75 150 0.4 1-1/2 x 1-1/4 35HB3014012 1.25 75 150 0.3 2 x 1 35HB3020010 1.38 40 80 0.6 2 x 1-1/4 35HB3020012 1.38 40 80 0.6 2 x 1-1/2 35HB3020014 1.38 40 80 0.6 size IN Part Number a IN Packing Weight LBInnerMaster 1/2 35SP3004 0.94 600 1200 0.07 3/4 35SP3006 1.12 350 700 0.1 1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 Fig. 35CP3 – Straight Coupling with Ribs Fig. 35RC3 – Hex Reducing Coupling Fig. 35HB3 – Hex Bushing Fig. 35SP3 – Square Head Plug Fig. 35U 3 – Union with Brass Seat Ductile Iron Fittings - Class 300 UL/FM SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com D U C T I l e A A A A A A A B B size IN Part Number a IN B IN Packing Weight LBInnerMaster 1-1/4 x 1 35RX3012010 1.67 1.58 15 30 1.2 1-1/2 x 1 35RX3014010 1.80 1.65 12 24 1.4 2 x 1 35RX3020010 2.02 1.73 8 16 2.0 size IN Part Number a IN Packing Weight LBInnerMaster 1 35X 3010 1.50 20 40 0.9 1-1/4 35X 3012 1.75 12 24 1.4 1-1/2 35X 3014 1.94 8 16 1.8 2 35X 3020 2.25 6 12 2.8 size IN Part Number a IN Packing Weight LBInnerMaster 1/2 35C 3004 0.87 300 600 0.1 3/4 35C 3006 0.97 200 400 0.1 1 35C 3010 1.16 110 220 0.2 1-1/4 35C 3012 1.28 70 140 0.4 1-1/2 35C 3014 1.33 50 100 0.5 2 35C 3020 1.45 25 50 0.8 2-1/2 35C 3024 1.70 18 36 1.6 Fig. 35X 3 – Cross Fig. 35RX3 – Reducing Cross Fig. 35C 3 – Cap Ductile Iron Fittings - Class 300 UL/FM size IN Part Number a IN Packing Weight LBInnerMaster 3/8 35BC3003 0.75 100 200 0.3 1/2 35BC3004 0.75 80 160 0.5 Fig. 35BC3 – Beam Clamp A SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com84SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 84 SMITH-COOPER INTERNATIONAL (SCI) warrants to its initial purchaser only, that its products which are delivered to this initial purchaser will be of the kind described in the order or price list and will be free of defects in workmanship or material for a period of five years from the date of delivery to our initial purchaser. Should any failure to conform to this warranty appear within five years after the date of the initial delivery to our initial purchaser, SCI will, upon written notification thereof and substantiation that the goods have been stored, installed, maintained and operated in accor- dance with recognized engineering and piping practices and industry standards, correct such defects by suitable repair or replacement (which alternative shall be at the discretion of SCI) of product at SCI’s own expense upon return of the defective part to SCI. In the event that SCI elects to replace the defective product, SCI shall pay up to $50 per defective product for total cost of replacement. In the event of multiple claims, such payment shall be no greater than $1,000 for each installation project. This warranty applies only during normal use that meets the above referenced conditions of installation and operation and is absolutely void if the product has been damaged after purchase or if it has been misused, repaired, altered or modified in any manner whatsoever. SCI shall not warranty any of its products if any portion of the product including without limitation, any component, gasket, housing or bolt has been modified, altered, remanufactured or replaced in any manner by any customer, user of the product or third party. Correction of non-conformities, in the manner and for the period of time provided above, shall constitute fulfillment of all liabilities of SCI to our initial purchaser, with respect to the goods, whether based on contract, negligence, strict tort, or otherwise. It is the intention of SCI that no warranty of any kind, whether expressed or implied shall pass through our initial purchaser to any other person or corpora- tion. No returns will be allowed unless prior written permission of SCI is first obtained. Buyers shall be responsible for all costs of transporta- tion as well as a restocking charge. This warranty is exclusively for the benefit of the initial purchaser of this product from SCI and, except to the extent prohibited by ap- plicable law, the foregoing warranty is in lieu of all other warranties, express or implied, including but not limited to warranties of fitness or merchantability. LIMITATIONS OF LIABILITY: SCI shall not under any circumstances be liable for special or consequential damages such as, but not limited to damage to loss of other property or equipment, loss of profits or revenue, cost of capital, cost of purchased or replacement goods, claims of customers of our initial purchaser, any labor cost for repair or replacement of the product or damage caused by the product. The remedies of our initial purchaser, and all others, set forth herein are exclusive, and the liability of SCI with respect to same shall not, except as expressly provided herein, exceed the price of the SCI products on which such liability is based. Warranty and Limitations of Liability © 2010 Smith-Cooper International® SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com85 Toll Free 800-766-0076 Fax 323-890-4456 www.smithcooper.com Industrial PVF Malleable Iron Cast Iron Ductile Iron Bronze Fittings Flanged Fittings Forged Steel Fittings Merchant Steel COOPLETS® Nipples Lead Free Valves Ball Gate Globe Check Butterfly Straight Stops Hose Bibbs / Sillcocks Boiler Drains Specialties Stainless Steel 150# Fittings 3000# Forged Fittings Weld Fittings Sanitary Fittings Compression Fittings Flanges Nipples Pipe & Tubing Valves Grooved Couplings Fittings Valves COOPLET® Adapter Nipples Los Angeles, CA · Atlanta, GA · Vancouver, WA · Chicago, IL 0710 Main Office/Manufacturing Facility •1375 Sampson Ave. •Corona, CA 92879 •Ph: 909.737.5599 •Fax: 909.737.0330 Customer Service •800.786.5266 www.tolco.com 86 wwwwww..ttoollccoo..ccoomm Revision 5/24/2001 ™ ®a brand of Fig. 200 - “Trimline” Adjustable Band Hanger Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil. Galvanized to G90 specifications Function — For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features — • (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. •(21/2" thru 8" Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals — Underwriters’ Laboratories listed (1/2" thru 8") in the USA (UL)and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature — 650°F Finish — Mil. Galvanized. For Stainless Steel materi- als, order TOLCO™ Fig. 200WON. Order By — Figure number and pipe size Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric ABLoad Lbs. Length 1/2 3/8 8mm or 10mm 3 1/8 25/8 400 11 3/4 3/8 8mm or 10mm 3 1/8 21/2 400 11 1 3/8 8mm or 10mm 3 3/8 25/8 400 12 11/4 3/8 8mm or 10mm 3 3/4 27/8 400 13 11/2 3/8 8mm or 10mm 3 7/8 27/8 400 14 2 3/8 8mm or 10mm 4 1/2 3 400 15 21/2 3/8 10mm 5 5/8 41/8 600 27 3 3/8 10mm 5 7/8 4 600 29 31/2 3/8 10mm 7 3/8 51/4 600 34 4 3/8 10mm 7 3/8 5 1000 35 5 1/2 12mm 9 1/8 61/4 1250 66 6 1/2 12mm 10 1/8 63/4 1250 73 8 1/2 12mm 13 1/8 83/4 1250 136 OFFICE/MANUFACTURING FACILITY •1375 SAMPSON AVE. •CORONA, CA 92879 •PH: 951.737.5599 •FAX: 951.737.0330 CUSTOMER SERVICE •800.786.5266 www.tolco.com 70 wwwwww..ttoollccoo..ccoomm™ ®a brand of Revision 8/15/2005 Size Range — Secures 3/8" thru 7/8" hanger rod Material — Carbon Steel Function — Secures channel to hanger rod for vertical seismic bracing. Approvals — Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish — Electro Galvanized Note — Available in HDG finish or Stainless Steel materials. Order By — Figure number Fig. 98 - Rod Stiffener Fig. 99 - All Thread Rod Cut to Length Size Range — Secures 3/8" thru 7/8" rod in 1" increments Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter, rod length and finish Fig. 100 - All Thread Rod Full Lengths Size Range — Secures 3/8" thru 7/8" rod in 10’ lengths Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter and finish Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 11/2 11630 10370 510 Component of State of California OSHPD Approved Seismic Restraints System 252 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.ca.hilti.com I Product Technical Guide 2006 Mechanical Anchoring Systems 4.3.8 HDI & HDI-L Drop-In Anchor The Hilti HDI/HDI-L Drop-In anchor is an internally threaded, flush mounted expansion anchor for use in concrete. Product Features HDI • Anchor, setting tool and Hilti drill bit form a matched tolerance system to provide reliable fastenings • Below surface setting for easy patchwork • Allows shallow embedment without sacrificing performance • Lip provides flush installation, consistent anchor depth, and easy rod alignment (HDI-L) • Lip allows accurate flush surface setting, independent of hole depth (HDI-L) • Ideal for repetitive fastenings with threaded rods of equal length • Intelligent expansion section adapts to the base material and reduces number of hammer blows up to 50% (HDI-L) Guide Specifications Expansion Anchor Expansion anchors shall be flush or shell type and zinc plated in accordance with ASTM B 633, SC 1, Type III. Anchors shall be Hilti HDI/HDI-L anchors as supplied by Hilti. Installation Install shell or flush type anchors in holes drilled with Hilti carbide tipped drill bits. Install anchors as per manufacturer’s recommendations. 4.3.8.2 Material Specifications HDI/HDI-L, 1/4", 3/8", 1/2", and HDI 5/8" and 3/4" are manufactured from mild carbon steel which is plated with a zinc finish for corrosion protection in accordance with ASTM B 633, SC 1, Type III HDI Stainless Steel material meets the requirements of AISI 303 4.3.8.3 Technical Data Listings/Approvals ICC-ES (International Code Council) ER-2895 (HDI Only) COLA (City of Los Angeles) Research Report No. 23709 (HDI Only) FM (Factory Mutual) Pipe Hanger Components for Automatic Sprinkler Systems (3/8" - 3/4") (HDI and HDI-L) UL (Underwriters Laboratories) UL 203 Pipe Hanger Equipment for Fire Protection Services (3/8" - 3/4") Anchor HDI/HDI-L HDI Size in. 1/4 3/8 1/2 5/8 3/4 Details (mm) (6.4) (9.5) (12.7) (15.9) (19.1) dbit Bit diameter1 in. 3/8 1/2 5/8 27/32 1 hnom Std. depth of embed.in. 1 1-9/16 2 2-9/16 3-3/16 Anchor length (mm) (25) (40) (51) (65) (81) h1 Hole depth th Useable thread in. 7/16 5/8 11/16 7/8 1-3/8 length (mm) (11) (15) (17) (22) (34) Threads per inch 20 16 13 11 10 h min. base material in. 3 3-1/8 4 5-1/8 6-3/8 thickness (mm) (76) (79) (102) (130) (162) Tmax max. tightening ft-lb 4 11 22 37 80 torque (Nm) (5.4) (14.9) (29.8) (50.2) (108.5) 4.3.8.1 Product Description Nd +Vd 1.0 (Ref. Section 4.1.2.7)Nrec Vrec Combined Shear and Tension Loading ( ) 5/3 ( ) 5/3 HDI/HDI-L Specification Table 1 For Hilti matched tolerance carbide tipped drill bits, see section 8.4.1. 4.3.8.1 Product Description 4.3.8.2 Material Specifications 4.3.8.3 Technical Data 4.3.8.4 Installation Instructions 4.3.8.5 Ordering Information Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.ca.hilti.com I Product Technical Guide 2006 253 Mechanical Anchoring Systems HDI & HDI-L Drop-In Anchor 4.3.8 Carbon Steel HDI Ultimate Loads in Concrete Carbon Steel HDI Allowable Loads in Concrete Note: The ultimate shear and allowable shear values are based on the use of SAE Grade 5 bolts, (fy = 85 ksi, Fult = 120 ksi) with the exception of the 1/4" HDI/HDI-L in f’c = 6000 psi concrete which is based upon the use of a SAE Grade 8 bolt (fy = 120 ksi, Fult = 150 ksi). Note:The ultimate and allowable shear values are based on the use of Type 18-8 bolts. 1 The allowable values are based on the use of SAE Grade 2 bolts installed in the anchors. 2 Based on using a safety factor of 4.0. 3 The tabulated shear and tensile values are for anchors installed in structural light- weight concrete having the designated ultimate compressive strength at the time of installation.The concrete must comply with ASTM C 330-77. 4 The tabulated shear and tensile values are for anchors installed through 20 gauge intermediate decking into structural lightweight concrete having the designated ultimate strength at the time of installation.The concrete must comply with ASTM C 330-77. Carbon Steel HDI Allowable Loads in Lightweight Concrete and Lightweight Concrete over Metal Deck1, 2 SS HDI – 1/4 (6.4)480 (2.1) 600 (2.7)740 (3.3)600 (2.7) SS HDI – 3/8 (9.5)1040 (4.6)1230 (5.5)1460 (6.5)1230 (5.5) SS HDI – 1/2 (12.7)1840 (8.2)2760 (12.4)2410 (10.7)2760 (12.3) SS HDI – 5/8 (15.9)2630 (11.7)4510 (20.1)3770 (16.8)4510 (20.1) SS HDI – 3/4 (19.1)3830 (17.0)5580 (24.8)5030 (22.4)5580 (24.8) Stainless Steel HDI Allowable Loads in Concrete 4000 psi (27.6 MPa)Anchor size in.(mm)Tension lb (kN)Shear lb (kN) 6000 psi (41.4 MPa) Tension lb (kN)Shear lb (kN) SS HDI – 1/4 (6.4)1930 (8.6)2400 (10.7)2950 (13.1)2400 (10.7) SS HDI – 3/8 (9.5)4170 (18.5)4920 (21.9)5850 (26.0)4920 (21.9) SS HDI – 1/2 (12.7)7350 (32.7)11040 (49.1)9630 (42.8)11040 (49.1) SS HDI – 5/8 (15.9)10540 (46.9)18040 (80.2)15100 (67.2)18040 (80.2) SS HDI – 3/4 (19.1)15340 (68.2)22320 (99.3)20130 (89.5)22320 (99.3) Stainless Steel HDI Ultimate Loads in Concrete 4000 psi (27.6 MPa)Anchor size in.(mm)Tension lb (kN)Shear lb (kN) 6000 psi (41.4 MPa) Tension lb (kN)Shear lb (kN) 2000 psi (13.8 MPa)4000 psi (27.6 MPa)6000 psi (41.4 MPa) Tension lb (kN)Shear lb (kN)Tension lb (kN)Shear lb (kN)Tension lb (kN)Shear lb (kN) HDI HDI-L HDI HDI-L HDI HDI-L HDI HDI-L HDI HDI-L HDI HDI-L 1/4 ( 6.4)1995 ( 8.9)1995 ( 8.9)1800 ( 8.0)1800 ( 8.0)2270 (10.1)2270 (10.1)2500 (11.1)2500 (11.1)3150 (14.0)3150 (14.0)2800 (12.5)2800 (12.5) 3/8 ( 9.5)3555 ( 15.8)3555 (15.8)3850 (17.1)3850(17.1)4460 (19.8)4460 (19.8)5000 (22.2)5000(22.2)5430 (24.2)5430 (24.2)6000 (26.7)6000 (26.7) 1/2 (12.7)4470 ( 19.9)4470 (19.9)6000 (26.7)6000 (26.7)7140 (31.8)7140 (31.8)8500 (37.8)7750 (34.4)9375 (41.7)9375 (41.7)10000 (44.5)10000 (44.5) 5/8 (15.9)7500 ( 33.4)– 10000 (44.5)– 11685 (52.0)– 13000 (57.8)– 14865 (66.1)– 15000 (66.7)– 3/4 (19.1)10000 ( 44.5)– 15500 (69.0) – 16260 (72.3)– 20000 (89.0)– 22250 (99.0)– 22000 (97.9)– Anchorsize in.(mm) 2000 psi (13.8 MPa)4000 psi (27.6 MPa)6000 psi (41.4 MPa) Tension lb (kN)Shear lb (kN)Tension lb (kN)Shear lb (kN)Tension lb (kN)Shear lb (kN) HDI HDI-L HDI HDI-L HDI HDI-L HDI HDI-L HDI HDI-L HDI HDI-L 1/4 ( 6.4)500 ( 2.2)500 (2.2)450 ( 8.0)450 (8.0)570 ( 2.5)570 (2.5)625 ( 2.8)625 (2.8)790 ( 3.5)790 ( 3.5)700 ( 3.1)700 ( 3.1) 3/8 ( 9.5)890 ( 4.0)890 (4.0)965 ( 4.3)965 (4.3)1115 ( 5.0)1115 (5.0)1250 ( 5.6)1250 (5.6)1360 ( 6.0)1360 ( 6.0)1500( 6.7)1500( 6.7) 1/2 (12.7)1120 ( 5.0)1120 (5.0)1500 ( 6.7)1500 (6.7)1785 ( 7.9)1785 (7.9)2125 ( 9.5)1940 (8.6)2345 (10.4)2345 (10.4)2500 (11.1)2500 (11.1) 5/8 (15.9)1875 ( 8.3)– 2500 (11.1)– 2920 (13.0)– 3250 (14.5)– 3715 (16.5)– 3750 (16.7)– 3/4 (19.1)2500 (11.1)– 3875 (17.2) – 4065 (18.1)– 5000 (22.2)– 5565 (24.8)– 5500 (24.5)– Anchorsize in.(mm) Anchor Anchor Installed in 3000 psi (20.7 MPa)Anchor Installed Through Steel Deck Upper Flute Anchor Installed Through Steel Deck Lower Flute Size Lt. Wt. Concrete 3 Into 3000 psi (20.7 MPa)Lt. Wt. Concrete 4 Into 3000 psi (20.7 MPa)Lt. Wt. Concrete 4 in.(mm)Tension, lb (kN)Shear, lb (kN)Tension, lb (kN)Shear, lb (kN)Tension, lb (kN)Shear, lb (kN) 1/4 (6.4)465 (2.1)340 (1.5)530 (2.4)335 (1.5)375 (1.7)250 (1.1) 3/8 (9.5)755 (3.4)940 (4.2)880 (3.9)1010 (4.5)500 (2.2)500 (2.2) 1/2 (12.7)1135 (5.0)1700 (7.6)1105 (4.9)1755 (7.8)625 (2.8)750 (3.3) 5/8 (15.9)1465 (6.5)2835 (12.6)– –875 (3.9)875 (3.9) 3/4 (19.1)2075 (9.2)3680 (16.4)– –1250 (5.5)1000 (4.4) 254 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.ca.hilti.com I Product Technical Guide 2006 Mechanical Anchoring Systems 4.3.8 HDI & HDI-L Drop-In Anchor cmin = 2.0 hnom, ccr = 3.0 hnom fRN = 0.2 c + 0.4 hnom for ccr > c > cmin cmin = 2.0 hnom, ccr = 3.0 hnom fRV = 0.35 c – 0.05 hnom for ccr> c > cmin Anchor Spacing and Edge Distance Guidelines (See Anchoring Technology Section 4.1.3) Anchor Spacing Adjustment Factors s = Actual Spacing smin = 2.0 hnom scr = 3.5 hnom Edge Distance Adjustment Factors c = Actual edge distance cmin = 2.0 hnom ccr = 3.0 hnom Load Adjustment Factors (Anchor Spacing) fA Tension/Shear Loads Load Adjustment Factors (Edge Distance) fR Spacing s in.(mm) Edge Distance c in.(mm) Anchor Diameter 1/4 3/8 1/2 5/8 3/4 Anchor Diameter 1/4 3/8 1/2 5/8 3/4 Anchor Diameter 1/4 3/8 1/2 5/8 3/4 Tension, fRN Shear, fRV smin = 2.0 hnom, scr = 3.5 hnom fA = 0.33 s – 0.17 hnom for scr > s > smin 2 ( 51) .50 2 ( 51) .80 .65 2-1/2 ( 64) .67 2-1/2 ( 64) .90 .83 3 ( 76) .83 .50 3 ( 76) 1.0 .80 1.0 .65 3-1/2 ( 89) 1.0 .58 3-1/2 ( 89) .85 .73 4 (102) .69 .50 4 (102) .91 .80 .85 .65 4-1/2 (114) .79 .58 4-1/2 (114) .98 .85 .96 .74 5 (127) .90 .67 .50 5 (127) 1.0 .90 .80 1.0 .83 .65 5-1/2 (140) 1.0 .75 .55 5-1/2 (140) .95 .83 .91 .70 6 (152) .83 .61 .50 6 (152) 1.0 .87 1.0 .77 7 (178) 1.0 .74 .57 6-1/2 (165) .91 .80 .84 .65 8 (203) .87 .67 7 (178) .95 .84 .91 .72 9 (229) 1.0 .77 8 (203) 1.0 .90 1.0 .83 10 (254) .88 9 (229) .96 .94 11 (279) .98 10 (254) 1.0 1.0 12 (305) 1.0 hnom = standard embedment depth Anchor Size hnom in. (mm)in. (mm) 1/4 (6.4)1 ( 25) 3/8 (9.5)1-9/16 (40) 1/2 (12.7)2 ( 51) 5/8 (15.8)2-9/16 ( 65) 3/4 (19.1)3-3/16 ( 81) Influence of Anchor Spacing & Edge Distance fA, fR