HomeMy WebLinkAboutF16-0048_RIVERHOUSE MATERIAL SUBMITTAL_1478907423.pdfMATERIAL SUBMITTAL FOR RIVERHOUSE 83 WILLOW PLACE VAIL , CO Prepared by: Tyler Williams Project Manager Western States Fire Protection Co. 7026 S. Tucson Way Centennial, CO 80112 Phone (303) 792-0022 Fax (303) 792-9049 Cell (720) 668-1160 Email: Tyler.Williams@wsfp.us WSFP #CS2887 August 26, 2016 Vail Fire & Emergency Services 09/22/16 Model ZW209FP Fire Protection Pressure Reducing Valve In-stock for fast delivery State-of-the-Art Construction • Rubber disc design forms a drip-tight seal • Inside and outside NSF approved epoxy coating provides resistance to harsh water and environmental conditions • Optional corrosion resistant stainless steel internals and pilot tubing provide long-lasting durability Ease of Installation and Service • Replaceable seat and internal components allow complete service without removal from the pipeline • UL/FM gauges come standard with three-way shut-off provide faster, low-cost installation and periodic monitoring • Pilot can be ordered on opposite side for convenient installation Lowest Life-Cycle Costs • Fully supported diaphragm reduces fatigue and increases the diaphragm life • O-ring stem seals for positive sealing and ease of repair • Savings over the ACV life-cycle due to reduced labor time and lower repair kit costs State-of-the-Art Design Stainless Steel Internals Gauges Come Standard Vail Fire & Emergency Services 09/22/16 Zurn Wilkins Model ZW209FP Form No. ZMKTG480-61, Rev 3/13 Zurn Wilkins, 1747 Commerce Way, Paso Robles, CA 93446 Phone: 855-ONE-ZURN (855-663-9876) Fax: 805-238-5766 In Canada: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone: 905-405-8272 Fax: 905-405-1292 Product Support Help Line: 877-BACKFLO (877-222-5356) • www.zurn.com SIZES GLOBE STYLE BODY: Flanged ends 1-1/2" thru 10" Grooved ends 1-1/2" thru 10" Threaded ends 1-1/4" thru 3" TEMPERATURE RATING: Water 33°F to 140°F PILOT SPRING RANGE: 50-165 psi Residual Pressure (155 psi Max 10") Refer to www.zurn.com for updated information MAX. INLET PRESSURE: 300 psi (class 300) STANDARD FEATURES ___ “Wye” Type Strainer ___ Inlet and Outlet Pressure Gauges (UL/FM) ___ 3-Way Gauge Isolation Valves ___ Epoxy Coated, FDA Approved ___ ANSI Class 300 Flanged OPTIONS (add suffix letters to ZW209FP) G Grooved Ends (inlet rating 300 psi) TH NPT Threaded (inlet rating 300 psi) X ANSI Class 150 Flanged (inlet rating 250 psi) RV Pilot on Reverse Side MATERIALS Main Valve Body Ductile Iron ASTM A536 Main Valve Cover Ductile Iron ASTM A536 Disc Guide Bronze ASTM B 176 Seat Bronze ASTM B 176 Disc Buna-N Rubber Diaphragm Nylon Reinforced Buna-N Stem Stainless Steel Spring Stainless Steel APPLICATION The Zurn Wilkins Model ZW209FP Pilot Operated Pressure Reducing Valve is designed specifically for Fire Suppression Systems to reduce high inlet pressures to a safe and stable outlet pressure. The pilot assembly reacts to changes in downstream pressure allowing the main valve to modulate between the closed and open position ensuring a constant downstream set pressure. Once the downstream pressure reaches the pilot setting, the main valve will seal shut preventing damage downstream. Pressure regulation is not dependent upon flow rate, resulting in minimal pressure loss through the valve. In addition the Models ZW209FP and ZW209FPG come standard with red epoxy coating internally and externally for corrosion protection, as well as isolation valves and pressure gauges for quick and easy maintenance or repair. STANDARDS AND PRESSURE RATINGS Standards Compliance UL Pressure Ratings Main Body ANSI/AWWA C530 Flanged CLASS 150 - ANSI B16.42 250 psi CLASS 300 - ANSI B16.42 300 psi Grooved IPS - AWWA C606 300 psi Threaded NPT - ANSI B1.20.1 300 psi TYPICAL INSTALLATION The upstream and downstream pressure gauges are required by Underwriters Laboratories® (UL). Also a relief valve of not less than 1/2" in size MUST be installed on the downstream side of the pressure control valve. Adequate drainage for the relief valve discharge must be provided. FLOW Vail Fire & Emergency Services 09/22/16 ES-A-C200_C200N Features • Extremely Compact Design • 70% Lighter than Traditional Designs • 304 (Schedule 40) Stainless Steel Housing & Sleeve • Groove Fittings Allow Integral Pipeline Adjustment • Patented Tri-Link Check Provides Lowest Pressure Loss • Unmatched Ease of Serviceability • Available with Grooved Butterfly Valve Shutoffs • Available for Horizontal, Vertical or N Pattern Installations • Replaceable Check Disc Rubber The Colt C200, C200N Double Check Valve Assemblies are used to prevent backflow of pollutants, that are objectionable but not toxic, from entering the potable water supply system. The Colt C200, C200N may be installed under continuous pressure service and may be subjected to backpressure. The Colt C200, C200N consists of two independently operating check valves, two shutoff valves, and four test cocks. For use in non-health hazard applications. The Colt C200, C200N features Lead Free* construction to comply with Lead Free* installation requirements. Specifications The Colt C200, C200N Double Check Valve Assembly shall consist of two independent Tri-Link Check modules within a single housing, sleeve access port, four test cocks and two drip tight shutoff valves. Tri-Link Checks shall be removable and serviceable, without the use of special tools. The housing shall be constructed of 304 (Schedule 40) stainless steel pipe with groove end connections. Tri-Link checks shall have reversible elastomer discs and in operation shall produce drip tight closure against the reverse flow of liquid caused by backpressure or backsiphonage. Lead Free* Double Check Valve Assembly shall be constructed using Lead Free* materials. It shall comply with state codes and standards, where applicable, requiring reduced lead content. Assembly shall be a Colt C200, C200N as manufactured by the Ames Company. ColtTM Series C200, C200N Double Check Valve Assemblies Sizes: 21⁄2" – 10" (65 – 250mm) C200N BFG C200 OSY LEAD FREE* * The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. Job Name ________________________________________________ Contractor ______________________________________________ Job Location ______________________________________________ Approval _______________________________________________ Engineer _________________________________________________ Contractor’s P.O. No. ______________________________________ Approval _________________________________________________ Representative ___________________________________________ Ames Fire & Waterworks product specifications in U.S. customary units and metric are ap prox i mate and are pro vid ed for ref er ence only. For precise mea sure ments, please contact Ames Fire & Waterworks Tech ni cal Ser vice. Ames Fire & Waterworks re serves the right to change or modify prod uct de sign, con struc tion, spec i fi ca tions, or ma te ri als with out prior notice and without in cur ring any ob li ga tion to make such chang es and mod i fi ca tions on Ames Fire & Waterworks prod ucts previously or sub se quent ly sold. NOTICE The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are re- quired to thoroughly read all installation instructions and product safety information before beginning the installation of this product. Vail Fire & Emergency Services 09/22/16 Size (DN) DimeNSiONS weiGht A C (OSY) C (NRS) D G H I J P C200NRS C200OSY C200N NRS C200N OSY in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. lbs. kgs. lbs. kgs. lbs. kgs. 21⁄2 65 303⁄4 781 163⁄8 416 93⁄8 238 31⁄2 89 291⁄16 738 211⁄2 546 151⁄2 393 813⁄16 223 93⁄16 234 115 52 125 57 123 56 133 60 3 80 313⁄4 806 187⁄8 479 101⁄4 260 311⁄16 94 301⁄4 768 221⁄4 565 171⁄8 435 93⁄16 233 101⁄2 267 131 59 145 66 144 65 158 72 4 100 333⁄4 857 223⁄4 578 123⁄16 310 4 102 33 838 231⁄2 597 181⁄2 470 915⁄16 252 113⁄16 284 161 73 161 73 184 83 184 83 6 150 431⁄2 1105 301⁄8 765 16 406 51⁄2 140 443⁄4 1137 331⁄4 845 233⁄16 589 131⁄16 332 15 381 273 124 295 134 314 142 336 152 8 200 493⁄4 1264 373⁄4 959 1915⁄16 506 611⁄16 170 541⁄8 1375 401⁄8 1019 277⁄16 697 1511⁄16 399 173⁄16 437 438 199 480 218 513 233 555 252 10 250 573⁄4 1467 453⁄4 1162 2313⁄16 605 83⁄16 208 66 1676 491⁄2 1257 321⁄2 826 175⁄16 440 20 508 721 327 781 354 891 404 951 431 Dimensions — Weights Configurations • Horizontal • Vertical up • “N” pattern horizontal Materials • Housing & Sleeve: 304 (Schedule 40) Stainless Steel • Elastomers: EPDM, Silicone and Buna ‘N’ • Tri-Link Checks: Noryl®, Stainless Steel • Check Discs: Reversible Silicone or EPDM • Test Cocks: Bronze Body Nickel Plated • Pins & Fasteners: 300 Series Stainless Steel • Springs: Stainless Steel Size (DN) DimeNSiONS weiGht A C D G H I J P C200BFG C200NBFG in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. lbs. kgs. 21⁄2 65 273⁄4 705 8 203 31⁄2 89 297⁄8 759 211⁄2 546 1415⁄16 379 813⁄16 223 9 229 56 25 64 29 3 80 281⁄4 718 85⁄16 211 311⁄16 94 3011⁄16 779 221⁄4 565 157⁄16 392 93⁄16 233 91⁄2 241 54 24 67 30 4 100 29 737 815⁄16 227 311⁄16 94 3115⁄16 811 231⁄2 597 161⁄4 412 915⁄16 252 10 254 61 28 84 38 6 150 361⁄2 927 10 254 5 127 433⁄16 1097 331⁄4 845 1911⁄16 500 131⁄16 332 101⁄2 267 117 53 157 71 8 200 423⁄4 1086 121⁄4 311 61⁄2 165 511⁄16 1297 401⁄8 1019 235⁄16 592 1511⁄16 399 143⁄16 361 261 118 337 153 Noryl® is a registered trademark of SABIC Innovative Plastics™. h A i J G P D C A D C (open) G h J i P C200, C200N C200BFG, C200NBFG Available Models Suffix: NRS - non-rising stem resilient seated gate valves OSY - UL/FM outside stem and yoke, resilient seated gate valves BFG - UL/FM grooved gear operated butterfly valves with tamper switch *OSY FxG - Flanged inlet gate connection and grooved outlet gate connection *OSY GxF - Grooved inlet gate connection and flanged outlet gate connection *OSY GxG - Grooved inlet gate connection and grooved outlet gate connection Available with grooved NRS gate valves - consult factory* Post indicator plate and operating nut available - consult factory* *Consult factory for dimensions Pressure — Temperature Tem per a ture Range: 33°F – 140°F (0.5°C – 60°C) Maximum Working Pres sure: 175psi (12.1 bar) Vail Fire & Emergency Services 09/22/16 Approvals • Approved by the Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR-USC) For additional approval information please contact the factory or visit our website at www.amesfirewater.com psi 14 12 10 8 6 4 2 0 0 50 100 150 200 250 300 350 gpm 0 190 380 570 760 950 1140 1330 lpm 7.5 15 fps psi 12 10 8 6 4 2 0 psi 12 10 8 6 4 2 0 0 100 200 300 400 500 gpm 0 380 760 1140 1520 1900 lpm 7.5 15 fps 21⁄2" (65mm) 3" (80mm) 0 300 600 900 1200 1500 gpm 0 1140 2280 3420 4560 5700 lpm 7.5 12 fps 6" (150mm) 0 100 200 300 400 500 600 700 800 gpm 0 380 760 1140 1520 1900 2280 2660 3040 lpm 7.5 13 fps 4" (100mm) psi 12 10 8 6 4 2 0 0 500 1000 1500 2000 2500 3000 3500 gpm 0 1900 3800 5700 7600 9500 11400 13300 lpm 7.5 10 fps 10" (250mm) psi 12 10 8 6 4 2 0 0 500 1000 1500 2000 2500 gpm 0 1900 3800 5700 7600 9500 lpm 7.5 10 fps 8" (200mm) psi 24 20 16 12 8 4 0 N V H H N V N V H N V H N H V N H V (**BFG & OSY Only) B64.5 1015 ** ** NOTICE Inquire with governing authorities for local installation requirements Capacity UL/FM Certified Flow Characteristics Flow characteristics collected using butterfly shutoff valves. Flow capacity chart identifies valve performance based upon rated water velocity up to 25fps • Service Flow is typically determined by a rated velocity of 7.5fps based upon schedule 40 pipe. • Rated Flow identifies maximum continuous duty perfor- mance determined by AWWA. • UL Flow Rate is 150% of Rated Flow and is not recom- mended for continuous duty. • AWWA Manual M22 [Appendix C] recommends that the maximum water velocity in services be not more than 10fps. *UL Rated Flow *UL Rated Flow Rated Flow Rated Flow Rated Flow Service Flow Service Flow PSi DROP(*FRiCtiON LOSS) PSi DROP (*FRiCtiON LOSS) *UL Rated Flow Rated Flow Service Flow PSi DROP (*FRiCtiON LOSS) *UL Rated Flow Service Flow PSi DROP(*FRiCtiON LOSS) *UL Rated Flow Ra ted Flow Service Flow PSi DROP (*FRiCtiON LOSS) *UL Rated Flow Rated Flow Service Flow PSi DROP (*FRiCtiON LOSS) Horizontal Vertical N - Pattern Vail Fire & Emergency Services 09/22/16 ES-A-C200C200N 1503 © 2015 Ames Fire & Waterworks USA: Backflow Tel: (978) 689-6066 • Fax: (978) 975-8350 • AmesFireWater.com USA: Control Valves Tel: (713) 943-0688 • Fax: (713) 944-9445 • AmesFireWater.com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • AmesFireWater.ca Latin America: Tel: (52) 81-1001-8600 • Fax: (52) 81-8000-7091 • AmesFireWater.com A Watts Water Technologies Company Vail Fire & Emergency Services 09/22/16 PRINTED IN USA PAGE 1 OF 4 VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD MFG. #5401146 - REV M 11/15 UL, CUL and CSFM Listed, FM Approved, LPCBApproved, For CE Marked (EN12259-5) / VdS Approved model use VSR-EU Service Pressure: 450 PSI (31 BAR) - UL Flow Sensitivity Range for Signal: 4-10 GPM (15-38 LPM) - UL Maximum Surge: 18 FPS (5.5 m/s) Contact Ratings: Two sets of SPDT (Form C) 10.0 Amps at 125/250VAC 2.0 Amps at 30VDC Resistive 10 mAmps min. at 24VDC Conduit Entrances: Two knockouts provided for 1/2" conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifications: • NEMA 4/IP54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fitting. • Temperature Range: 40°F - 120°F, (4.5°C - 49°C) - UL • Non-corrosive sleeve factory installed in saddle. Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 • Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. • Shock hazard. Disconnect power source before servicing. Serious injury or death could result. • Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. Ordering Information Nominal Pipe Size Model Part Number 2" DN50 VSR-2 1144402 2 1/2" DN65 VSR-2 1/2 1144425 3" DN80 VSR-3 1144403 3 1/2" - VSR-3 1/2 1144435 4" DN100 VSR-4 1144404 5" - VSR-5 1144405 6" DN150 VSR-6 1144406 8" DN200 VSR-8 1144408 Specifications subject to change without notice. Optional: Cover Tamper Switch Kit, stock no. 0090148 Replaceable Components: Retard/Switch Assembly, stock no. 1029030 Waterflow switches that are monitoring wet pipe sprinkler systems shall not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterflow switches used for this application may result in unintended discharges caused by surges, trapped air, or short retard times. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-1211/Canada 888-882-1833 • www.pottersignal.com General Information The Model VSR is a vane type waterflow switch for use on wet sprinkler systems. It is UL Listed for use on a steel pipe; schedules 5 through 40, sizes 2" - 6" and is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8" (50 mm thru 200 mm). LPC approved sizes are 2" thru 8" (50 mm thru 200 mm). See Ordering Information chart. The VSR may also be used as a sectional waterflow detector on large systems. The VSR contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. Enclosure The VSR switches and retard device are enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin number 5401103 for installation instructions of this switch. Important: This document contains important information on the installation and operation of the VSR waterflow switches. Please read all instructions carefully before beginning installation. A copy of this document is required by NFPA 72 to be maintained on site. Vail Fire & Emergency Services 09/22/16 PRINTED IN USA MFG. #5401146 - REV M 11/15 PAGE 2 OF 4 VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Installation (see Fig. 1) These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they shall be installed on the top side of the pipe where they will be accessible. The device should not be installed within 6" (15 cm) of a fitting which changes the direction of the waterflow or within 24" (60 cm) of a valve or drain. NOTE: Do not leave cover off for an extended period of time. Drain the system and drill a hole in the pipe using a hole saw in a slow speed drill (see Fig. 1). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterflow. Take care not to damage the non-corrosive bushing in the saddle. The bushing should fit inside the hole in the pipe. Install the saddle strap and tighten nuts alternately to required torque (see the chart in Fig. 1). The vane must not rub the inside of the pipe or bind in any way. ADAPTER USE (2) 5180162 ADAPTERS AS SHOWN ABOVE DN50 ONLY ADAPTER 50mm 20mm ±2mm MAX. DWG# 1146-1F Fig. 1 NOTE: For copper or plastic pipe use Model VSR-CF. Retard Adjustment The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting (60-90 seconds). The time delay should be set at the minimum required to prevent false alarms (Flowing water activates device in one direction only.) DO NOT LEAVE COVER OFF FOR AN EXTENDED PERIOD OF TIME TIGHTEN NUTS ALTERNATELY MOUNT ON PIPE SO ARROW ON SADDLE POINTS IN DIRECTION OF WATERFLOW ROLL PADDLE IN OPPOSITE DIRECTION OF WATERFLOW DIRECTION OF WATERFLOW Hole must be drilled perpendicular to the pipe and vertically centered. Refer to the Compatible Pipe/Installation Requirements chart for size. Correct Incorrect Compatible Pipe/ Installation Requirements Model Nominal Pipe Size Nominal Pipe O.D. Pipe Wall Thickness Hole Size U-Bolt Nuts Torque Lightwall Schedule 10 (UL) Schedule 40 (UL) BS-1387 (LPC) DN (VDS) inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm ft-lb n-m VSR-2 2 DN50 2.375 60.3 .065 1.651 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 1.25 + .125/- .062 33.0 ± 2.0 20 27 VSR-2 1/2 2.5 - 2.875 73.0 .084 2.134 0.120 3.05 0.203 5.16 - - - - VSR-2 1/2 - DN65 3.000 76.1 - - - - - - 0.142 3.6 0.102 2.6 VSR-3 3 DN80 3.500 88.9 .083 2.108 0.120 3.05 0.216 5.49 0.157 4.0 0.114 2.9 2.00 ± .125 50.8 ± 2.0 VSR-3 1/2 3.5 - 4.000 101.6 - - 0.120 3.05 0.226 5.74 - - - - VSR-4 4 DN100 4.500 114.3 .084 2.134 0.120 3.05 0.237 6.02 0.177 4.5 0.126 3.2 VSR-5 5 - 5.563 141.3 - - 0.134 3.40 0.258 6.55 - - - - VSR-6 6 DN150 6.625 168.3 .115 2.921 0.134 3.40 0.280 7.11 0.197 5.0 0.157 4.0 VSR-8 8 DN200 8.625 219.1 - - 0.148 3.76 0.322 8.18 0.248 6.3 0.177 4.5 Do not trim the paddle. Failure to follow these instructions may prevent the device from operating and will void the warranty. Do not obstruct or otherwise prevent the trip stem of the flow switch from moving when water flows as this could damage the flow switch and prevent an alarm. If an alarm is not desired, a qualified technician should disable the alarm system. Vail Fire & Emergency Services 09/22/16 PRINTED IN USA PAGE 3 OF 4 VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD MFG. #5401146 - REV M 11/15 To remove knockouts: Place screwdriver at inside edge of knockouts, not in the center. DWG 1146-4 Fig. 2 Do not drill into the base as this creates metal shavings which can create electrical hazards and damage the device. Drilling voids the warranty. Fig. 4 Switch Terminal Connections Clamping Plate Terminal Fig. 3 Break out thin section of cover when wiring both switches from one conduit entrance. Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system shall be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector’s test valve shall always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR is not recommended or advisable. A minimum flow of 10 GPM (38 LPM) is required to activate this device. Advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. Fig. 6 Mounting Dimensions DWG. 1146-14 3.50 in (89.0 mm) 2.34 in (59.4 mm) PIPE DIA. + 5.25 in (+ 133.4 mm) 5.56 in (141.2 mm) 2.00 in (50.8 mm) U-BOLT NUT U-BOLT WASHER PIPE SADDLE PIPE PLASTIC PADDLE U-BOLT NOMINAL PIPE DIA. +1.75 in (+44.5 MM) FOR DN 50 – DN 65 2–2.5 in NOMINAL PIPE DIA. +2.125 in (+54.0 MM) FOR DN 80 – DN 200 3–8 in DWG 1146-15 GREEN GROUND SCREWS Fig. 7 An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. Do not strip wire beyond 3/8" of length or expose an uninsulated conductor beyond the edge of the terminal block. When using stranded wire, capture all strands under the clamping plate. Notes: 1. The Model VSR has two switches, one can be used to operate a central station, proprietary or remote signaling unit, while the other contact is used to operate a local audible or visual annunciator. 2. For supervised circuits, see “Switch Terminal Connections” drawing and warning note (Fig. 4). Fig. 5 Typical Electrical Connections LOAD TO BELL NEUTRAL FROM BELL CONNECTOR EOL (End Of Line Resistor) BELL NEUTRAL FROM BREAKER BREAKER LINE FROM BREAKER NOTE: When connecting to a UL Listed control panel, use the panel’s resistor value for circuit supervision. Vail Fire & Emergency Services 09/22/16 PRINTED IN USA MFG. #5401146 - REV M 11/15 PAGE 4 OF 4 VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Removal of Waterflow Switch • To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterflow detectors are removed or replaced. • Turn off electrical power to the detector, then disconnect wiring. • Loosen nuts and remove U-bolts. • Gently lift the saddle far enough to get your fingers under it. With your fingers, roll the vane so it will fit through the hole while continuing to lift the waterflow detector saddle. • Lift detector clear of pipe. Fig. 8 Retard/Switch Assembly Replacement (See Fig. 8) The Retard/Switch Assembly is field-replaceable without draining the system or removing the waterflow switch from the pipe 1. Make sure the fire alarm zone or circuit connected to the waterflow switch is bypassed or otherwise taken out of service. 2. Disconnect the power source for local bell (if applicable). 3. Identify and remove all wires from the waterflow switch. 4. Remove the (2) mounting screws holding retard/switch assembly to the base. Do not remove the (2) retard housing screws. 5. Remove the retard assembly by lifting it straight up over the tripstem. 6. Install the new retard assembly. Make sure the locating pins on the retard/switch assembly fit into the locating pin bosses on the base. 7. Re-install the (2) original mounting screws. 8. Reconnect all wires. Perform a flow test and place the system back in service. Maintenance Inspect detectors monthly. If leaks are found, replace the detector. The VSR waterflow switch should provide years of trouble-free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock #1029030 (see Fig. 8). There is no maintenance required, only periodic testing and inspection. DWG# 1146-10 BREAK OUT THIN SECTION OF COVER WHEN WIRING BOTH SWITCHES FROM ONE CONDUIT ENTRANCE. DO NOT REMOVE (2) RETARD HOUSING SCREWS REMOVE (2) ORIGINAL MOUNTING SCREWS HOLDING RETARD/SWITCH ASSEMBLY TO BASE RETARD/SWITCH ASSEMBLY (2) ORIGINAL MOUNTING SCREWS (2) LOCATING PINS (2) LOCATING PIN BOSSES IN BASE BASE Vail Fire & Emergency Services 09/22/16 Fire Protection Valve • threaded or Grooved Body Style • Full Port design 1" - 2" • Standard Port Design 2¹⁄₂" MATeRIAL LIST PART SPeCIFICATION 1߰ Body Bronze ASTM B584 Alloy C84400 2߰ Ball Chrome Plated Brass ASTM B124 Alloy C37700 3߰ Seat Ring Carbon-filled PTFE 4߰ Thrust Washer Reinforced PTFE 5߰ Stem Bronze ASTM B371 Alloy C69430 6߰ Stem O-Ring Nitrile 7߰ Retaining Washer Brass 8߰ Retaining Ring Steel 9߰ Ground Wire Screw Steel 10߰ 505-8 Act Assy߰ Brass 11߰ Body End Bronze ASTM B584 Alloy C84400 12߰ Mounting Screw Steel 13߰ Lock Washer Steel 14߰ Handle Pin Brass 15߰ Hand Wheel Steel/plastisol coated (1¹⁄₄" -2¹⁄₂") Brass Tee Handle (1") 16߰ Indicator Flag Painted Steel 17߰ Body Gasket Elastomer 18߰ Lead Screw O-Ring Nitrile 19߰ Thrust Washer Anti-friction Polymer 20߰ Cover Gasket Buna-N 21߰ Flag Seal O-Ring Nitrile 22߰ Tamper-Proof Screw Stainless Steel 23߰ Pipe Plug (-4 units) Stainless Steel (Not shown) Refer to page 42 for details for TS-2M Switch Kit߰ 300 PSI WWP Bronze Ball Valves 300 PSI/20߰7 Bar Non-Shock Cold Water COnFOrMS tO MSS SP-110 • FM APPrOVed FOr indOOr And OUtdOOr SerViCe • UL LiSted FOr indOOr And OUtdOOr SerViCe* • CALIFORNIA STATE FIRE MARSHAL LISTING NO߰ 7770-1243:103 1 2 3 4 5 6 7 8 9 10 20 16 11 22 21 14 15 17 18 19 12 13 DIMeNSIONS—WeIGHTS—QUANTITIeS Dimensions A B Weight Size Threaded Grooved Threaded Grooved C D e F G Cv† Threaded Grooved Box Master In߰ mm߰ In߰ mm߰ In߰ mm߰ In߰ mm߰ In߰ mm߰ In߰ mm߰ In߰ mm߰ In߰ mm߰ In߰ mm߰ In߰ mm߰ Value Lbs߰ Kg߰ Lbs߰ Kg߰ Qty߰ Ctn߰ Qty߰ 1 25 3߰33 85 – – 1߰66 42 – – 2߰11 54 3߰81 97 2߰31 59 6߰14 156 1߰75 44 57 6߰1 2߰77 – – 1 10 1¹⁄₄ 32 4߰18 106 – – 2߰09 53 – – 2߰46 62 4߰21 107 2߰72 69 6߰33 161 3߰50 89 103 7߰1 3߰23 – – 1 8 1¹⁄₂ 40 4߰70 119 – – 2߰35 60 – – 2߰95 74 4߰46 113 2߰97 75 6߰33 161 3߰50 89 143 8߰1 3߰68 – – 1 4 2 50 5߰15 131 6߰71 170 2߰57 65 3߰36 85 3߰69 94 4߰67 119 3߰18 81 6߰33 161 3߰50 89 245 10߰7 4߰86 9߰7 4߰40 1 4 2¹⁄₂ 65 5߰65 144 7߰28 185 2߰92 74 3߰64 93 3߰75 95 4߰67 119 3߰18 81 6߰33 161 3߰50 89 183 13߰0 5߰91 12߰6 5߰73 1 4 † Note: Cv is defined as the flow in GPM that a valve will carry with a pressure drop of 1߰0 psi when the media is water at 60° F߰ DO NOT USe FOR NATURAL GAS KT-505-W-8 Threaded KT-505-W KG-505-W-8 Grooved (2" & 21" only) Dezincification Resistant * Compliance with the applicable requirements of the Standard for Butterfly Valves for Fire ProtectionService, UL 1091B߰ NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 6 AHEAD OF THE FLOW® www.nibco.com Revision 11/14/2014 Vail Fire & Emergency Services 09/22/16