Loading...
HomeMy WebLinkAboutF17-0007_wilkins 950xlbf (1)_1493227560.pdfZurn Industries, LLC | Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada | Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Rev. B Date: 12/13 Document No. BF-950XLBF Product No. Model 950XLBF Model 950XLBF Double Check Valve Assembly Page 1 of 2 A B C D E950XLWILKINS ZURNASSE 1015Options (Suffixes can be combined) SS - with butterfly valve supervisory switches (UL and FM Approved for indoor and outdoor use) FT - with "Fast Test" test cocks Accessories Repair kit (rubber only) Thermal expansion tank (Model XT) Bronze wye strainer QT-SET Quick Test Fitting Set Application Designed for installation on water lines to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Assembly shall provide protection where a potential non-health hazard exists. Standards Compliance • UL® Classified • C-UL® Classified Materials Main valve body Cast Bronze ASTM B 584 Access covers Cast Bronze ASTM B 584 Fasteners Stainless Steel, 300 Series Elastomers Silicone (FDA approved) Buna Nitrile (FDA approved) Polymers Noryl™, NSF Listed Springs Stainless steel, 300 series Test cock cover Plastic Features Sizes: 1 1/4", 1 1/2", 2" Maximum working water pressure 175 PSI Maximum working water temperature 180°F Hydrostatic test pressure 350 PSI End connections Threaded ANSI B1.20.1 Dimensions & Weights (do not include pkg.) ഌFlow Characteristics Zurn Industries, LLC | Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada | Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Page 2 of 2 Typical Installation Local codes shall govern installation requirements. To be installed in accordance with the manufacturer’s instructions and the latest edition of the Uniform Plumbing Code. Un- less otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. VERTICAL INSTALLATION Speci cations The Double Check Type Backflow Preventer shall be rated to 180°F and supplied with butterfly valves. The main body and access covers shall be bronze (ASTM B 584), the seat ring and all internal polymers shall be NSF® Listed Noryl™ and the seat disc elastomers shall be SILICONE. The first and second check shall be accessible for maintenance without removing the device from the line. The Double Check Type Backflow Preventer shall be a ZURN WILKINS Model 950XLBF.DIRECTION OF FLOW950XLWILKINS ZURNASSE 1015