DRB17-0353_Damper - Greenheck VCD23_1502290140.pdf
Application and Design The VCD-23 series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric and pneumatic actuators are available.Ratings (See page 4 for specific limitations) Pressure: Up to 5.0 in. wg (1.2 kPa) - pressure differential Velocity: Up to 3000 fpm (15.2 m/s) Leakage: Class 1A @ 1 in. wg (.25 kPa) Class 1 @ up to 5 in. wg (1.2 kPa) Temperature: Up to 250°F (121°C) (Consult Greenheck for higher temperatures) * W&H dimension furnished approximately 1/4 in. (6mm) undersize. Shown with optional extension pin and standoff bracket. VCD-23 Low Leakage CONTROL DAMPER Flange Options Opposed BladesParallel Blades 5 in.5 in. 1 1/4 in.max. (typical) 1 1/4 in.max. (typical) Blade Operation Construction Standard Optional Frame Material Galvanized Steel 304SS Frame Thickness 16 ga.12 ga. (2.7mm) Frame Type 5 in. x 1 in. Channel - Blade Material Galvanized steel 304SS Blade Thickness 16 ga.- Blade Type 3V - Blade Seals TPE Silicone, None* Axle 1⁄2 in. dia. Plated Steel 304SS Axle Bearings Synthetic 304SS Linkage Material Plated Steel 304SS Jamb Seal 304SS - Paint Finishes Mill Finish Baked Enamel, Epoxy, HI Pro Polyester, Industrial Epoxy W x H Minimum Size Maximum Size Single Section Multiple Section Inches 6 x 6 48 x 74 Unlimited mm 152 x 152 1219 x 1880 Unlimited Size Limitations Features & Options • Blade seals - pressure activated to produce tighter sealing. • Linkage concealed in the frame • Low profile head and sill are used on sizes less than 17 in. (432mm) • Wide range of electric & pneumatic actuators and manual quadrant available. Factory installation available. • Sleeves available • 5/8 in. - 2 in. (16mm - 51mm) flange available • Retaining angles • Transitions- R, C and O • Open Close Indicator (OCI) • Security bars H* W* Single Flange Double FlangeReversed Flange 5 in.5 in.5 in. 1 1/2 in. (Typical) Shown with optional internally mounted actuator. *AMCA leakage applies when damper is provided with blade seals. Installation instructions available at www. greenheck.com. Pressure Drop Data VCD-23 This pressure drop testing was conducted in accordance with AMCA Standard 500-D using the three configurations shown. All data has been corrected to represent standard air at a density of .075 lb/ft3 (1.2 kg/m3). Actual pressure drop found in any HVAC system is a combination of many factors. This pressure drop information along with an analysis of other system influences should be used to estimate actual pressure losses for a damper installed in a given HVAC system. AMCA Test Figures Figure 5.2 Illustrates a ducted damper exhausting air into an open area. This configuration has a lower pressure drop than Figure 5.5 because entrance losses are minimized by a straight duct run upstream of the damper. Figure 5.3 Illustrates a fully ducted damper. This configuration has the lowest pressure drop of the three test configurations because entrance and exit losses are minimized by straight duct runs upstream and downstream of the damper. Figure 5.5 Illustrates a plenum mounted damper. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system. 5D 6D 5D D 4 (W) (H) 3.14 5D 6D 5D D 4 (W) (H) 3.14 5D 6D 5D D 4 (W) (H) 3.14 5D 6D 5D D 4 (W) (H) 3.14 5D 6D 5D D 4 (W) (H)3.14 AMCA Certified Pressure Drop Data VCD-23 Velocity (fpm)Pressure Drop (in. wg)Velocity (fpm)Pressure Drop (in. wg)Velocity (fpm)Pressure Drop (in. wg) 500 0.01 500 0.01 500 0.01 1000 0.05 1000 0.03 1000 0.02 1500 0.11 1500 0.06 1500 0.05 2000 0.19 2000 0.10 2000 0.09 2500 0.29 2500 0.16 2500 0.14 3000 0.41 3000 0.23 3000 0.19 3500 0.55 3500 0.30 3500 0.27 4000 0.72 4000 0.40 4000 0.35 12 in. x 12 in. (305mm x 305mm)24 in. x 24 in. (610mm x 610mm)36 in. x 36 in. (914mm x 914mm) Velocity (fpm)Pressure Drop (in. wg) 500 0.01 1000 0.03 1500 0.07 2000 0.12 2500 0.18 3000 0.26 3500 0.36 4000 0.47 48 in. x 12 in. (1219mm x 305mm) Velocity (fpm)Pressure Drop (in. wg) 500 0.01 1000 0.04 1500 0.08 2000 0.15 2500 0.22 3000 0.32 3500 0.43 4000 0.56 12 in. x 48 in. (305mm x 1219mm) AMCA 5.2 AMCA 5.3 AMCA 5.5 Velocity (fpm)Pressure Drop (in. wg)Velocity (fpm) Pressure Drop (in. wg)Velocity (fpm)Pressure Drop (in. wg) 500 0.01 500 0.01 500 0.01 1000 0.03 1000 0.02 1000 0.02 1500 0.08 1500 0.04 1500 0.03 2000 0.13 2000 0.07 2000 0.06 2500 0.20 2500 0.11 2500 0.09 3000 0.29 3000 0.16 3000 0.13 3500 0.40 3500 0.21 3500 0.19 4000 0.51 4000 0.28 4000 0.25 12 in. x 12 in. (305mm x 305mm)24 in. x 24 in. (610mm x 610mm)36 in. x 36 in. (914mm x 914mm) Velocity (fpm)Pressure Drop (in. wg) 500 0.01 1000 0.03 1500 0.06 2000 0.10 2500 0.16 3000 0.22 3500 0.30 4000 0.39 48 in. x 12 in. (1219mm x 305mm) Velocity (fpm)Pressure Drop (in. wg) 500 0.01 1000 0.03 1500 0.07 2000 0.12 2500 0.18 3000 0.26 3500 0.36 4000 0.46 12 in. x 48 in. (305mm x 1219mm) Velocity (fpm)Pressure Drop (in. wg)Velocity (fpm)Pressure Drop (in. wg)Velocity (fpm)Pressure Drop (in. wg) 500 0.03 500 0.03 500 0.03 1000 0.13 1000 0.12 1000 0.13 1500 0.30 1500 0.26 1500 0.29 2000 0.53 2000 0.47 2000 0.52 2500 0.82 2500 0.75 2500 0.82 3000 1.19 3000 1.04 3000 1.19 3500 1.62 3500 1.41 3500 1.63 4000 2.10 4000 1.90 4000 2.13 12 in. x 12 in. (305mm x 305mm)24 in. x 24 in. (610mm x 610mm)36 in. x 36 in. (914mm x 914mm) Velocity (fpm)Pressure Drop (in. wg) 500 0.03 1000 0.12 1500 0.28 2000 0.49 2500 0.77 3000 1.12 3500 1.53 4000 2.01 48 in. x 12 in. (1219mm x 305mm) Velocity (fpm)Pressure Drop (in. wg) 500 0.03 1000 0.12 1500 0.27 2000 0.47 2500 0.75 3000 1.07 3500 1.45 4000 1.91 12 in. x 48 in. (305mm x 1219mm) 5D 6D 5D D 4 (W) (H) 3.14 Greenheck Fan Corporation certifies that the model VCD-23 shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs.The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance ratings. 24 0 12 36 48 60 74 012243648 Damper Width (in.)Damper Height (in.)3000fpm 2000fpm2500fpm Velocity Limitations AMCA Certified Leakage Data VCD-23 Air leakage is based on operation between 32°F (0°C) and 120°F (49°C). Tested for leakage in accordance with ANSI/AMCA Standard 500-D, Figure 5.5. Tested for air performance in accordance with ANSI/AMCA Standard 500-D, Figures 5.2, 5.3 and 5.5. Torque Data are based on a torque of 5.0 in.lb./ft² (0.56 N·m) applied to close and seat the damper during the test. VCD-23 Leakage Class* Maximum Damper Width 1 in. wg (0.25 kPa) 4 in. wg (1 kPa) 5 in. wg (1.2 kPa) 48 in. (1219mm)1A 1 1 *Leakage Class Definitions The maximum allowable leakage is defined by AMCA as the following: • Leakage Class 1A - 3 cfm/ft2 @ 1 in. wg (class 1A is only defined at 1 in. wg). • Leakage Class 1 - 4 cfm/ft2 @ 1 in. wg - 8 cfm/ft2 @ 4 in. wg - 11 cfm/ft2 @ 8 in. wg - 12.6 cfm/ft2 @ 10 in. wg Greenheck Fan Corporation certifies that the model VCD-23 shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs.The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance ratings. Application Data Space Envelopes On dampers less than 18 in. (457mm) high, actuators may also require clearances above and/or below the damper frame. “B” and “T” dimensions are worst case clearance requirements for some dampers less than 18 in. (457mm) high. All damper sizes under 18 in. (457mm) high do not require these worst case clearances. If space availability above or below the damper is limited, each damper size should be individually evaluated. T B D Damper frame OptionalJackshaft Actuator Type/Model Height T B D Inches (mm)Inches AFBUP (-S) and FSNF Series, Belimo MSxx20 Series, Honeywell; 33x-2976 Series, Siemens >6 to <10 0 123⁄4 6 >10 to <18 0 2 6 >18 0 0 6 FSLF, LF and TFB Series, Belimo >6 to <10 0 31⁄2 6 >10 0 0 6 MSxx04 & MSxx09 Series, Honeywell >6 to <9 0 43⁄4 6 >9 0 0 6 MS75xx Series, Honeywell >6 to <10 0 123⁄4 6 >10 to <18 0 7 6 >18 0 0 6 33x-4551 Series, Siemens >6 to <10 0 71⁄2 6 >10 to <17 0 11⁄2 6 >17 0 0 6 331-2856, Siemens <12 N/A N/A N/A >12 to <18 0 21⁄2 9 >18 0 0 9 1 1/4 in. (32mm)max. 3 3/4 in.(95mm) 5 3/8 in.(136.5mm) 5 in. (127mm) Actuator 7 3/4 in.(197mm) This drawing depicts the worse case clearance requirements for an actuator with a jackshaft. Application Data and Specifications Multi-Section Assembly Dampers larger than the maximum single section size, will be made up of a multiple of equal size sections. Multiple section dampers can be jackshafted together so that all sections operate together as shown below. NOTE: Dampers larger than 48 in. x 74 in. (1219mm x 1880mm) are not intended to be structurally self supporting. Additional horizontal bracing is recommended to support the weight of the damper and vertical bracing should be installed as required to hold against system pressure. Specifications Control dampers meeting the following specifications shall be furnished and installed where shown on plans and/or as described in schedules. Damper blades shall be 16 ga. (1.5mm) galvanized steel 3V type with three longitudinal grooves for reinforcement. Blades shall be completely symmetrical relative to their axle pivot point, presenting identical resistance to airflow and operation in either direction through the damper (blades that are non-symmetrical relative to their axle pivot point or utilize blade stops larger than 1⁄2 in. [13mm] are unacceptable). Blade seals shall be TPE. Linkage shall be blade-to-blade concealed in jamb (out of the airstream) to protect linkage and reduce pressure drop and noise. Damper frame shall be 16 ga. (1.5mm) galvanized steel formed into a structural hat channel shape with reinforced corners to meet 11 ga. (3.1mm) criteria. Bearings shall be corrosion resistant, permanently lubricated, synthetic (acetal) sleeve type rotating in extruded holes in the damper frame for maximum service. Axles shall be square and positively locked into the damper blade. Jamb seals shall be flexible stainless steel compression type to prevent leakage between blade end and damper frame. The damper manufacturer’s submittal data shall certify all air leakage and air performance pressure drop data is licensed in accordance with the AMCA Certified Ratings Program for Test Figures 5.2, 5.3 and 5.5. Damper air performance data shall be developed in accordance with the latest edition of AMCA Standard 500-D. Basis of design is Greenheck's model VCD-23. Copyright © 2017 Greenheck Fan Corporation VCD-23 Rev 18 February 2017