HomeMy WebLinkAboutF16-0016_FP4_1478909315.pdfA 7/12 UNDER CAB H F B A G VFY ELEV. HOISTWAY REQ'S co2 co2 co2 SD SD SDSD SD FLAT CLG @ 8'-0"(FIN) VAULTED FLAT CLG @ 6'-11-9/16"(FIN) FLAT CLG @ 8'-0" (FIN) VAULTED VAULTED FLAT CLG @7'-10"(FIN) FLAT CLG @ 7'-10" FIN) FLAT CLG @ 7'-10" (FIN) FLAT CLG @ 7'-10"(FIN) VAULTED ROOF SLOPE ROOF SLOPE ROOF SLOPE ROOF SLOPE ROOF SLOPE ROOF SLOPE FLAT CLG @ 7'-8"(FIN) FLAT CLG @ 7'-8" (FIN) FLAT CLG @ 7'-8" (FIN) VAULTED VAULTED FLAT CLG VAULTED FLAT CLG @ 7'-10" (FIN) SD FLAT CLG @ 7'-8" (FIN) FLAT CLG @ 7'-10" (FIN) SD SD SD SD 7'-9-3/8" Plate Ht-Fin Clg 13'-4" Ridge-Fin Clg 13'-4" Ridge-Fin Clg 7'-9-3/8" Plate Ht-Fin Clg FLAT CLG @ 7'-8"(FIN) FLAT CLG @ 7'-8" (FIN) FLAT CLG @ 7'-8" (FIN) FLAT CLG @ 7'-8" (FIN) FLAT CLG @ 7'-8" (FIN) 7'-8" Plate Ht-Fin Clg 7'-8" Plate Ht-Fin Clg 7'-10" Plate Ht-Fin Clg 7'-10" Plate Ht-Fin Clg 14'-9" Ridge-Fin Clg 14'-9" Ridge-Fin Clg FLAT CLG @7'-10"(FIN) FLAT CLG @ 7'-10" (FIN) VAULTED 7'-8" Plate Ht-Fin Clg DA Name: 1 DA Area: 298.58 104 heads for this project 36 heads for lower level 30 heads for main level 38 heads for upper level This system as shown on company print no dated for at contract no is designed to discharge at a rate of a maximum area of when supplied with water at a rate of Occupancy classification: Commodity classification: Maximum storage height: Storage arrangement: Number of heads flowing: System Type: Maximum velocity: Flow from In-Rack sprinklers: Flow from Overhead sprinklers: Flow from Inside Hoses: Flow from Outside Hoses: Other fixed flows: Total flow in system piping: Additional flow at/beyond source: Total of all flows: Calculation results for Design Area JSPIWð /PLQPð RI IORRU DUHD RYHU - Surplus Pressure at Source: Pressure Required at Source: Pressure Available at Source: at at the base of the riser. Hose stream allowance of is included in the above. 1 Living Room Phoenix Hughes Res 994 Ptarmingan 0.1  IWð 79.4 gpm 57.7 psi Res 4 Wet 13.9 ft/s 0 gpm 79.4 gpm 0 gpm 0 gpm 0 gpm 79.4 gpm 0 gpm 79.4 gpm 57.7 psi 79.4 psi 21.7 psi 5 16 16 ACCEPTING THIS COPY IS DEEMED AS AGREEING TO THE FOLLOWING: THIS DRAWING COPY, ITS CONTENTS, INFORMATION AND PRINCIPALS OF DESIGN ARE THE EXCLUSIVE PROPERTY OF THE FIRE PROTECTION CONTRACTOR LISTED AND MILE HIGH DESIGN GROUP, LLC AND IS BEING SUBMITTED TO YOU WITH THE UNDERSTANDING THAT IT IS NOT TO BE REPRODUCED, COPIED OR MODIFIED IN ANY MANNER; NEITHER SHALL IT BE RELAYED IN WHOLE OR IN PART TO ANY OTHER INDIVIDUAL OR FIRM FOR ANY OTHER PROJECT OR EXTENSION OF THIS PROJECT EXCEPT THRU WRITTEN AGREEMENT WITH THE FIRE PROTECTION CONTRACTOR AND MILE HIGH DESIGN GROUP, LLC. ERRORS AS A RESULT OF THIS FILE BEING ELECTRONICALLY TRANSMITTED ARE BEYOND THE CONTROL OF AND ARE NOT THE RESPONSIBILITY OF THE FIRE PROTECTION CONTRACTOR OR MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR INSTALLATION OR INSPECTION OF WORK INSTALLED. THESE PLANS ARE DIAGRAMMATICAL ONLY. ON SITE COORDINATION MUST BE ARRANGED WITH ALL OBSTRUCTIONS, i.e.: MECHANICAL, ELECTRICAL, AND STRUCTURAL. ANY ALTERATIONS FROM ENGINEERED DRAWINGS MUST BE APPROVED BY MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR LAYOUT DESIGN ISSUES OR CONFLICTS WITH ANY OBSTRUCTIONS. IF ADDITIONAL FIRE SPRINKLER PIPING AND/OR FIRE SPRINKLER HEADS ARE REQUIRED THIS WILL BE THE RESPONSIBILITY OF THE FIRE SPRINKLER CONTRACTOR. ALL CHANGES MUST ME APPROVED BY MILE HIGH DESIGN GROUP, LLC THE OWNER IS RESPONSIBLE TO PROVIDE SUFFICIENT HEAT THROUGHOUT THIS BUILDING TO PREVENT FREEZING OF WATER IN THE FIRE SPRINKLER SYSTEM -5151 Bannock St. Denver, CO 80216 303-291-1012 303-383-5023 FAX firesprinkler@afssco.com A FIRE SPRINKLER DESIGN COMPANY Vail Fire & Emergency Services 06/06/16