HomeMy WebLinkAboutF16-0024_CS2772 submittal Final Design_1478909353.pdf7026 South Tucson Way Centennial, CO 80112 (303) 792-0022 Fax (303) 792-9049 Fire Protection System Hydraulic Calculations and Equipment Commissary Fire Sprinkler System 263 E. Gore Creek Vail, Colorado 81657 Prepared by: Zack Hinson Project Manager Phone: (303) 792-0022 Cell: (720) 346-3113 Fax: (303) 792-9049 Email: Zachary.hinson@wsfp.us November 4, 2015 These documents need to installed in documents folder Vail Fire & Emergency Services 11/01/16 Hydraulic Summary Report Description: Light Hazard Job Number: CS2772 Node Flow(gpm) Total Hose Streams 100.0 Safety Margin Required Available Node Hose Flow Static Residual Flow Total Demand (gpm) (psi) (psi) (gpm) (psi) (gpm) (psi) (psi) @ @ Name 1 121.5 107.0 14.4 1300.0 100.0 118.0 123.0 681.3 Water Supply Design Engineer Job Number Total Water Required (Including Hose Allowance) 681.3 Maximum Pressure Unbalance In Loops 0.0 Additional Hose Supplies 100.0 Hose Allowance At Source Supplies 61.9gal 176.7gal Light Hazard 0.10gpm/ft² 225.00ft² 1500.00ft² (Actual 943.55ft²) 9 Occupancy Area of Application Coverage Per Sprinkler Number Of Sprinklers Calculated Density Job Suffix AutoPeak Results: Pressure For Remote Area(s) Adjacent To Most Remote Area Volume capacity of Dry Pipes Volume capacity of Wet Pipes 14.13 between nodes 1 and 4 Maximum Velocity Under Ground 26.22 between nodes 19 and 107 Maximum Velocity Above Ground 5.6 K-Factor 20.3 at 13.1 Most Demanding Sprinkler Data System Vail, CO 81657 Job Site/Building 263 E Gore Creek AHJ Commissary Job State Certification/License Number Job Name: Zack Hinson CS2772 Contractor Contractor Number Name of Contractor: Western States Fire Protection Address 1 274 Center Drive Address 2 Glenwood Springs, CO. 81601 Contact Name Contact Title PM Extension Phone 720-346-3133 FAX E-mail zachary.hinson@wsfp.us Web-Site Zack Hinson Address 3 Address 1 Address 2 Drawing Name CS2772 Commissary - Final Design System Flow Demand 581.3 Remote Area(s) Address 3 5/19/2016 © M.E.P.CAD, Inc. Page 1 AutoSPRINK® 12 v12.0.52.0 4:02:52PM Vail Fire & Emergency Services 11/01/16 Hydraulic Graph Report Description: Light Hazard Job Number: CS2772 118.0 @ 1300.0 Residual: Pressure 123.0 Static: Pressure Water Supply at Node 1 Hydraulic Graph Water Supply at Node 1 107.0 @ 581.3 107.0 @ 681.3 Available Pressure at Time of Test 121.5 @ 681.3 System Demand System Demand (Including Hose Allowance at Source) © M.E.P.CAD, Inc. 5/19/2016 Page 2 AutoSPRINK® 12 v12.0.52.0 4:02:58PM Vail Fire & Emergency Services 11/01/16 Device (gpm) Actual Flow Minimum Flow (gpm) (K) K-Factor (psi) Pressure Summary Of Outflowing Devices Report Description: Light Hazard Job Number: CS2772 Sprinkler 101 19.9 15.0 5.6 12.6 Sprinkler 102 20.3 20.3 5.6 13.1 Sprinkler 103 24.7 20.3 5.6 19.5 Sprinkler 104 25.5 18.0 5.6 20.7 Sprinkler 105 25.6 21.0 5.6 20.9 Sprinkler 106 25.6 21.0 5.6 21.0 Sprinkler 107 24.8 22.5 5.6 19.7 Sprinkler 108 25.9 18.0 5.6 21.4 Sprinkler 109 26.8 23.5 5.6 22.9 Sprinkler 110 26.1 22.5 5.6 21.7 Sprinkler 111 30.0 22.5 5.6 28.6 Sprinkler 112 27.4 22.5 5.6 24.0 Sprinkler 113 30.7 23.5 5.6 30.1 Sprinkler 114 29.9 22.5 5.6 28.5 Sprinkler 115 32.5 21.0 5.6 33.6 Sprinkler 116 27.1 22.5 5.6 23.4 Sprinkler 117 32.5 22.5 5.6 33.7 Sprinkler 118 30.0 22.5 5.6 28.6 Sprinkler 119 33.1 18.0 5.6 34.8 Sprinkler 120 35.4 18.0 5.6 40.0 Sprinkler 121 27.6 22.5 5.6 24.2 Most Demanding Sprinkler Data © M.E.P.CAD, Inc. 5/19/2016 Page 3 AutoSPRINK® 12 v12.0.52.0 4:03:04PM Vail Fire & Emergency Services 11/01/16 Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: CS2772 Report Description: Light Hazard • • • • • Route 1 • • • • • Pf Pe Pv DR 1.049 20.3 7.52 0.186573 0'-6 0.8 102 19'-0 20.3 5.6 13.1 3'-6¾ -0.2 10 19'-6 13.6 4'-0¾ 100 Sprinkler, T(3'-6¾) Pf Pe Pv AO 1.049 40.1 14.90 0.661704 7'-4-5/8 6.8 10 19'-6 19.9 + 19.9 13.6 2'-10¼ 11 19'-6 20.4 10'-2-7/8 100 Flow (q) from Route 4, Flow (q) from Route 4 and 3 2E(1'-5-1/8) Pf Pe Pv AO 1.610 64.9 10.22 0.199674 6'-0½ 1.2 11 19'-6 24.7 + 24.7 20.4 12 19'-6 21.6 6'-0½ 100 Flow (q) from Route 6, Flow (q) from Route 6 and 4 Pf Pe Pv AO 2.067 90.3 8.64 0.109086 1'-0-1/8 0.5 12 19'-6 25.5 + 25.5 21.6 3'-6¾ 13 19'-6 22.1 4'-7 100 Flow (q) from Route 12, Flow (q) from Route 12 and 7 E(3'-6¾) Pf Pe Pv BL 2.157 90.3 7.93 0.088640 9'-8-3/8 1.4 13 19'-6 22.1 6'-1¾ -1.7 14 23'-4¼ 21.8 15'-10-1/8 100 E(4'-4-5/8), EE(1'-9) Pf Pe Pv BL 2.157 115.9 10.18 0.140618 7'-0-3/8 1.0 14 23'-4¼ 25.6 + 25.6 21.8 -0.9 15 25'-4-5/8 21.9 7'-0-3/8 100 Flow (q) from Route 7, Flow (q) from Route 7 and 5 Pf Pe Pv BL 2.157 141.6 12.43 0.203505 5'-6-1/8 1.1 15 25'-4-5/8 25.6 + 25.6 21.9 -0.7 20 26'-11-5/8 22.4 5'-6-1/8 100 Flow (q) from Route 8, Flow (q) from Route 8 and 6 Pf Pe Pv BL 2.157 167.5 14.70 0.277655 3'-6-7/8 1.5 20 26'-11-5/8 25.9 + 25.9 22.4 1'-9 -0.4 23 28'-0 23.4 5'-3-7/8 100 Flow (q) from Route 13, Flow (q) from Route 13 and 8 EE(1'-9) Pf Pe Pv BL 2.635 167.5 9.85 0.104750 2'-3¼ 0.2 23 28'-0 23.4 0.3 25 27'-3-3/8 24.0 2'-3¼ 100 Pf Pe Pv BL 2.635 194.3 11.43 0.137871 15'-6¾ 4.2 25 27'-3-3/8 26.8 + 26.8 24.0 14'-8¼ 3.4 28 19'-6 31.5 30'-3 100 Flow (q) from Route 3, Flow (q) from Route 3 and 2 EE(2'-11¼), 2E(5'-10½) Pf Pe Pv BL 2.635 225.0 13.24 0.180884 8'-7½ 3.7 28 19'-6 30.7 + 30.7 31.5 11'-9 29 19'-6 35.2 20'-4½ 100 Flow (q) from Route 15, Flow (q) from Route 15 and 9 2E(5'-10½) Pf Pe Pv BL 2.635 257.4 15.15 0.232098 5'-8-3/8 1.3 29 19'-6 32.5 + 32.5 35.2 35 19'-6 36.5 5'-8-3/8 100 Flow (q) from Route 19, Flow (q) from Route 19 and 10 Pf Pe Pv BL 2.635 290.5 17.09 0.290227 6'-10 5.4 35 19'-6 33.1 + 33.1 36.5 11'-9 37 19'-6 41.9 18'-7 100 Flow (q) from Route 20, Flow (q) from Route 20 and 11 2E(5'-10½) Pf Pe Pv BL 2.635 325.9 19.17 0.359050 11'-3 10.4 37 19'-6 35.4 + 35.4 41.9 17'-7-3/8 38 19'-6 52.3 28'-10-3/8 100 Flow (q) from Route 21, Flow (q) from Route 21 and 12 E(5'-10½), T(11'-9) Pf Pe Pv FR 3.260 325.9 12.53 0.127346 12'-1 1.5 38 19'-6 52.3 5.2 9 7'-5 59.0 12'-1 100 Pf Pe Pv CM 3.260 325.9 12.53 0.127346 30'-7 7.7 9 7'-5 59.0 29'-8½ 2.2 8 2'-5 68.9 60'-3-3/8 100 3E(6'-8½), DPV(9'-7) Pf Pe Pv CM 3.260 325.9 12.53 0.090887 145'-3-1/8 22.7 8 2'-5 68.9 104'-10 -2.4 2 7'-11 89.2 250'-1-1/8 120 9E(9'-4-7/8), T(20'-1-7/8) Pf Pe Pv AO 4.026 581.3 14.65 0.132916 7'-4½ 2.5 2 7'-11 255.4 89.2 11'-4-7/8 2.3 4 2'-6 94.1 18'-9-3/8 100 Flow (q) from Route 2 E(7'-1½), LtE(4'-3-3/8) Pf Pe Pv UG 4.100 581.3 14.13 0.065271 21'-10¾ 13.4 4 2'-6 94.1 20'-0 -0.4 1 3'-6 107.0 41'-10¾ 140 BFP(-5.7), PRV(-5.0), 2E(10'-0), S 681.3 100.0 Hose Allowance At Source 1 © M.E.P.CAD, Inc. 5/19/2016 Page 4 AutoSPRINK® 12 v12.0.52.0 4:03:09PM Vail Fire & Emergency Services 11/01/16 Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: CS2772 Report Description: Light Hazard • • • • • Route 2 • • • • • Pf Pe Pv DY 0.622 24.8 26.22 2.475578 0'-0 7.4 107 17'-9-5/8 24.8 5.6 19.7 3'-0 -0.1 19 17'-11 27.0 3'-0 120 Sprinkler, PO(3'-0) Pf Pe Pv BL 1.055 54.5 19.98 0.534233 1'-0½ 1.6 19 17'-11 29.6 27.0 2'-0 17 17'-11 28.7 3'-0½ 150 Flow (q) from Route 10 C(2'-0) Pf Pe Pv BL 1.291 80.6 19.75 0.412563 14'-8-3/8 9.0 17 17'-11 26.1 28.7 7'-0 22 17'-11 37.6 21'-8-3/8 150 Flow (q) from Route 5 2Tr(1'-0), E(2'-0), T(3'-0) Pf Pe Pv BL 1.291 84.4 20.69 0.449927 43'-9½ 21.1 22 17'-11 3.9 37.6 3'-0 18 17'-11 58.7 46'-9½ 150 Flow (q) from Route 24 T(3'-0) Pf Pe Pv CM 2.009 255.4 25.85 0.404836 2'-3 0.9 18 17'-11 171.0 58.7 16 17'-11 59.6 2'-3 150 Flow (q) from Route 9 Pf Pe Pv FR 2.635 255.4 15.03 0.163257 10'-0 4.1 16 17'-11 59.6 14'-9-7/8 4.3 7 7'-11 68.0 24'-9-7/8 120 fT(14'-9-7/8) Pf Pe Pv FM 2.635 255.4 15.03 0.163257 53'-5 15.4 7 7'-11 68.0 41'-2¼ 6 7'-11 83.4 94'-7¼ 120 2T(16'-5¾), E(8'-2-7/8) Pf Pe Pv FM 2.469 255.4 17.12 0.224128 13'-0¼ 4.3 6 7'-11 83.4 6'-0 5 7'-11 87.7 19'-0¼ 120 E(6'-0) Pf Pe Pv FM 3.068 255.4 11.08 0.077820 12'-7¾ 1.5 5 7'-11 87.7 7'-0 3 7'-11 89.2 19'-7¾ 120 E(7'-0) Pf Pe Pv AO 4.026 255.4 6.44 0.029028 1'-0 0.0 3 7'-11 89.2 2 7'-11 89.2 1'-0 100 • • • • • Route 3 • • • • • Pf Pe Pv DR 1.049 26.8 9.95 0.313555 0'-9-7/8 1.4 109 26'-6 26.8 5.6 22.9 3'-6¾ -0.3 25 27'-3-3/8 24.0 4'-4-5/8 100 Sprinkler, PO(3'-6¾) • • • • • Route 4 • • • • • Pf Pe Pv DR 1.049 19.9 7.39 0.180553 5'-3-5/8 1.2 101 19'-0 19.9 5.6 12.6 1'-5-1/8 -0.2 10 19'-6 13.6 6'-8-5/8 100 Sprinkler, E(1'-5-1/8) • • • • • Route 5 • • • • • Pf Pe Pv BL 1.055 26.1 9.58 0.137166 16'-7-1/8 3.2 110 26'-7 26.1 5.6 21.7 6'-6 3.8 17 17'-11 28.7 23'-1-1/8 150 Sprinkler, 3E(2'-0), Tr(0'-6) • • • • • Route 6 • • • • • Pf Pe Pv DR 1.049 24.7 9.18 0.270188 0'-6 1.1 103 19'-0 24.7 5.6 19.5 3'-6¾ -0.2 11 19'-6 20.4 4'-0¾ 100 Sprinkler, T(3'-6¾) • • • • • Route 7 • • • • • Pf Pe Pv DR 1.049 25.6 9.50 0.287732 0'-7¼ 1.2 105 22'-9¼ 25.6 5.6 20.9 3'-6¾ -0.3 14 23'-4¼ 21.8 4'-2-1/8 100 Sprinkler, PO(3'-6¾) • • • • • Route 8 • • • • • Pf Pe Pv DR 1.049 25.6 9.52 0.288700 0'-4½ 1.1 106 25'-0¼ 25.6 5.6 21.0 3'-6¾ -0.2 15 25'-4-5/8 21.9 3'-11¼ 100 Sprinkler, PO(3'-6¾) • • • • • Route 9 • • • • • Pf Pe Pv BL 1.055 27.1 9.95 0.147081 1'-9¼ 0.6 116 17'-11 27.1 5.6 23.4 2'-0 30 17'-11 24.0 3'-9¼ 150 Sprinkler, PO(2'-0) Pf Pe Pv BL 1.055 24.9 9.15 0.126013 6'-2-5/8 1.0 30 17'-11 24.0 2'-0 36 17'-11 25.0 8'-2-5/8 150 T(2'-0) Pf Pe Pv BL 1.055 52.5 19.27 0.499613 7'-10 4.2 36 17'-11 27.6 25.0 0'-6 34 17'-11 29.2 8'-4 150 Flow (q) from Route 11 Tr(0'-6) Pf Pe Pv BL 1.291 82.5 20.21 0.430877 6'-5 3.2 34 17'-11 30.0 29.2 1'-0 33 17'-11 32.4 7'-5 150 Flow (q) from Route 16 Tr(1'-0) Pf Pe Pv BL 1.291 56.7 13.89 0.215257 7'-3¾ 2.0 33 17'-11 32.4 2'-0 32 17'-11 34.4 9'-3¾ 150 2Tr(1'-0) © M.E.P.CAD, Inc. 5/19/2016 Page 5 AutoSPRINK® 12 v12.0.52.0 4:03:09PM Vail Fire & Emergency Services 11/01/16 Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: CS2772 Report Description: Light Hazard Pf Pe Pv BL 1.291 89.2 21.86 0.497839 36'-9¾ 22.8 32 17'-11 32.5 34.4 9'-0 31 17'-11 57.2 45'-9¾ 150 Flow (q) from Route 18 7Tr(1'-0), E(2'-0) Pf Pe Pv CM 2.009 89.2 9.03 0.057781 19'-1-5/8 1.1 31 17'-11 57.2 21 17'-11 58.3 19'-1-5/8 150 Pf Pe Pv CM 2.009 171.0 17.31 0.192695 1'-10½ 0.4 21 17'-11 81.8 58.3 18 17'-11 58.7 1'-10½ 150 Flow (q) from Route 14 • • • • • Route 10 • • • • • Pf Pe Pv BL 1.055 29.6 10.87 0.173184 14'-11½ 3.0 112 17'-11 2.2 5.6 24.0 2'-6 19 17'-11 27.0 17'-5½ 150 Sprinkler,, Flow (q) from Route 23, Flow (q) from Route 23 E(2'-0), Tr(0'-6) • • • • • Route 11 • • • • • Pf Pe Pv BL 1.055 27.6 10.12 0.151713 3'-2-5/8 0.8 121 17'-11 27.6 5.6 24.2 2'-0 36 17'-11 25.0 5'-2-5/8 150 Sprinkler, T(2'-0) • • • • • Route 12 • • • • • Pf Pe Pv DR 1.049 25.5 9.45 0.284849 0'-6 1.2 104 19'-0 25.5 5.6 20.7 3'-6¾ -0.2 12 19'-6 21.6 4'-0¾ 100 Sprinkler, T(3'-6¾) • • • • • Route 13 • • • • • Pf Pe Pv DR 1.049 25.9 9.61 0.209750 0'-2½ 1.1 108 26'-9¼ 25.9 5.6 21.4 5'-0 -0.1 20 26'-11-5/8 22.4 5'-2½ 120 Sprinkler, PO(5'-0) • • • • • Route 14 • • • • • Pf Pe Pv BL 1.055 29.9 10.98 0.176457 4'-9-3/8 1.5 114 17'-11 29.9 5.6 28.5 4'-0 27 17'-11 30.1 8'-9-3/8 150 Sprinkler, E(2'-0), T(2'-0) Pf Pe Pv AO 1.055 59.9 21.98 0.637100 2'-10-3/8 3.1 27 17'-11 30.0 30.1 2'-0 26 17'-11 33.2 4'-10-3/8 150 Flow (q) from Route 17 T(2'-0) Pf Pe Pv BL 1.291 85.7 21.00 0.462426 6'-6-1/8 4.4 26 17'-11 25.8 33.2 3'-0 24 17'-11 37.6 9'-6-1/8 150 Flow (q) from Route 22 Tr(1'-0), E(2'-0) Pf Pe Pv BL 1.291 81.8 20.05 0.424578 43'-9½ 20.7 24 17'-11 37.6 5'-0 21 17'-11 58.3 48'-9½ 150 2Tr(1'-0), T(3'-0) • • • • • Route 15 • • • • • Pf Pe Pv DR 1.049 30.7 11.40 0.403192 0'-6 1.6 113 19'-0 30.7 5.6 30.1 3'-6¾ -0.2 28 19'-6 31.5 4'-0¾ 100 Sprinkler, PO(3'-6¾) • • • • • Route 16 • • • • • Pf Pe Pv BL 1.055 30.0 11.00 0.176915 1'-6-3/8 0.6 118 17'-9-5/8 30.0 5.6 28.6 2'-0 -0.1 34 17'-11 29.2 3'-6-3/8 150 Sprinkler, T(2'-0) • • • • • Route 17 • • • • • Pf Pe Pv BL 1.055 30.0 11.00 0.176996 6'-2¾ 1.5 111 17'-11 30.0 5.6 28.6 2'-0 27 17'-11 30.1 8'-2¾ 150 Sprinkler, T(2'-0) • • • • • Route 18 • • • • • Pf Pe Pv BL 1.055 32.5 11.93 0.205599 1'-6¼ 0.7 117 17'-11 32.5 5.6 33.7 2'-0 32 17'-11 34.4 3'-6¼ 150 Sprinkler, PO(2'-0) • • • • • Route 19 • • • • • Pf Pe Pv DR 1.049 32.5 12.05 0.446517 0'-6 1.8 115 19'-0 32.5 5.6 33.6 3'-6¾ -0.2 29 19'-6 35.2 4'-0¾ 100 Sprinkler, T(3'-6¾) • • • • • Route 20 • • • • • Pf Pe Pv DR 1.049 33.1 12.27 0.461990 0'-6 1.9 119 19'-0 33.1 5.6 34.8 3'-6¾ -0.2 35 19'-6 36.5 4'-0¾ 100 Sprinkler, T(3'-6¾) • • • • • Route 21 • • • • • Pf Pe Pv DR 1.049 35.4 13.15 0.524671 0'-6 2.1 120 19'-0 35.4 5.6 40.0 3'-6¾ -0.2 37 19'-6 41.9 4'-0¾ 100 Sprinkler, T(3'-6¾) • • • • • Route 22 • • • • • Pf Pe Pv BL 1.291 25.8 6.32 0.050188 13'-0 0.8 33 17'-11 32.4 3'-0 26 17'-11 33.2 16'-0 150 T(3'-0) • • • • • Route 23 • • • • • © M.E.P.CAD, Inc. 5/19/2016 Page 6 AutoSPRINK® 12 v12.0.52.0 4:03:09PM Vail Fire & Emergency Services 11/01/16 Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: CS2772 Report Description: Light Hazard Pf Pe Pv BL 1.055 2.2 0.80 0.001380 11'-0¼ 0.0 30 17'-11 24.0 2'-6 112 17'-11 24.0 13'-6¼ 150 E(2'-0), Tr(0'-6) • • • • • Route 24 • • • • • Pf Pe Pv BL 1.055 3.9 1.42 0.004003 1'-10½ 0.0 24 17'-11 37.6 4'-0 22 17'-11 37.6 5'-10½ 150 T(2'-0) T(2'-0) 1.51 Pipe Type Legend AO Arm-Over BL Branch Line CM Cross Main DN Drain DR Drop DY Dynamic FM Feed Main FR Feed Riser MS Miscellaneous OR Outrigger RN Riser Nipple SP Sprig ST Stand Pipe UG Underground Units Legend Diameter Inch Elevation Foot Flow gpm Discharge gpm Velocity fps Pressure psi Length Foot Friction Loss psi/Foot HWC Hazen-Williams Constant Pt Total pressure at a point in a pipe Pn Normal pressure at a point in a pipe Pf Pressure loss due to friction between points Pe Pressure due to elevation difference between indicated points Pv Velocity pressure at a point in a pipe Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Ee1 11¼° Elbow Ee2 22½° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap 4.87)( 150 1.33 140 1.16 130 0.713 100 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter = Factor C Value Multiplier Value Of C Multiplying Factor © M.E.P.CAD, Inc. 5/19/2016 Page 7 AutoSPRINK® 12 v12.0.52.0 4:03:09PM Vail Fire & Emergency Services 11/01/16 Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Bulletin 518 Bulletin 518 Features 1. Differential Latch-type, lightweight, depend- able construction. 2. Easily trimmed for releasing by: · Manual pull stations · Wet pilot sprinklers · Dry pilot actuators · Solenoid valves 3. Drop in or Screw in seat & clapper assembly simplifies maintenance. 4. Bronze or Stainless steel seat with O-ring seals resists corrosion and leakage. 5. Pressure-actuated clapper facing provides dependable seal. 6. Reset externally. Cover removal is not required. 7. Grooved inlet and outlet connections Flanged connections available on 4” (100mm), 6” (150mm), 165mm & 8” (200mm). 8. Drain valve to drain standing water column. 9. Valve latches in open position. No pressure- operated relief valve is required. 10. Pressure rating of 250 psi (17,2 bar) or 300 psi (20,7 bar) (4” (100mm), 6” (150mm) & 165mm Only). Listings & Approvals (Only when used with Reliable’s Trim Sets.) 1. Listed by Underwriters Laboratories, Inc. and UL certified for Canada (cULus). 2. Certified by Factory Mutual Approvals (FM). 3. NYC MEA 258-93-E 4. LPCB (4” (100mm), 165mm, 6” (150mm) & 8” (200mm) only) 5. CE 6. VdS Schadenverhütung GmbH The Reliable Model DDX Deluge Valve is a hydraulically op- erated, latching clapper-type valve used to control the water supply to a deluge or preaction system. Deluge systems use open sprinklers or nozzles as discharge outlets in the fire area, while preaction systems use closed sprinklers or nozzles. Both systems use separate detection devices to control the operation of the Deluge Valve. Three simple trim arrangements allow for actuation of the Reliable Model DDX Deluge Valve by utilizing manual, hydraulic, pneumatic, or electrical devices. These de- vices include break glass stations, wet pilot sprinklers, dry pilot sprinklers, thermal detectors, and smoke detectors. The Reliable Model DDX Deluge Valve can be reset exter- nally, without cover removal. This is accomplished by pushing in and turning the external reset knob at the rear of the Deluge Valve (see Fig. 2). Fig. 2 518 Fig. 1 Model DDX Deluge Valve 2” (50 mm), 2½” (65 mm), 3” (80 mm), 76 mm, 4” (100 mm), 6” (150 mm), 165 mm & 8” (200 mm) Vail Fire & Emergency Services 11/01/16 2. Fig. 3 Vail Fire & Emergency Services 11/01/16 Valve Operation The Reliable Model DDX Deluge Valve is shown in both closed and open positions in Fig. 3. In the closed position, the supply pressure acts on the underside of the clapper and also on the push rod through the push rod chamber’s inlet restric- tion. The resultant force due to the supply pressure acting on the push rod is multiplied by the mechanical advantage of the lever and is more than sufficient to hold the clapper closed against normal supply pressure surges. When a fire is detected, a releasing device vents the push rod chamber to atmosphere through the chamber’s outlet. Since the pressure cannot be replenished through the inlet restriction as rapidly as it is vented, the push rod chamber pressure falls instantaneously. When the push rod chamber pressure ap- proaches approximately one-third of the supply pressure, the upward force of the supply pressure acting beneath the clapper overcomes the lever-applied force thereby opening the clapper. Once the clapper has opened, the lever acts as a latch, pre- venting the clapper from returning to the closed position. Water from the supply flows through the Deluge Valve into the system piping. Water also flows through the Deluge Valve’s alarm outlet to the alarm devices. After system shutdown, resetting the Model DDX Deluge Valve is quite simple. Doing so only requires pushing in and turning the reset knob at the rear of the valve (see Fig. 2). The external reset feature of the Model DDX Deluge Valve provides a means for simple, economical system testing, which is one es- sential facet of a good maintenance program. The external reset feature does not, however, eliminate another important facet of good maintenance, namely, periodic cleaning and inspection of the internal valve parts. In the event that water builds up inside the valve due to con- densate from the air supply system, or water left inside from valve system testing, a drain is available for venting. After clos- ing the main supply valve, a small valve over the drain cup can be opened slightly until the water inside the valve body and the main pipe column has drained. Whenever ambient temperature conditions are high, the water temperature in the Model DDX Deluge Valve’s pushrod chamber could possibly increase, thereby increasing the pres- sure in the chamber to values exceeding the rated pressure of the system. In an indoor installation where standard room tem- peratures are exceeded, a pressure relief kit may be needed. Pressure relief kit, P/N 6503050001, can be installed into the pushrod chamber’s releasing line to limit the pressure to 250 psi (17,2 bar). Reliable Model DDX Deluge Valve with associated trim sizes 2” (50 mm), 2½” (65 mm), 76 mm, 3” (80 mm), 4” (100 mm), 165 mm, 6” (150 mm) or 8” (200 mm), are rated for use at a mini- mum water supply pressure of 20 psi (1,4 bar) and a maximum water supply pressure of 250 psi (17,2bar) for 2” (50mm), 2½” (65mm), 3” (80mm), 76mm & 8” (200mm) valve sizes and 300 psi (20,7 bar) for 4” (100mm), 6” (150mm) & 165mm valve siz- es.. Water supplied to the inlet of the valve and to the push rod chamber must be maintained between 40°F (4°C) and 140°F (60°C). 3. Detection and Actuation In general, the Reliable Model DDX Deluge Valve can be re- leased by any Reliable UL Listed or FM Approved device that opens sufficiently to vent the push rod chamber in response to a fire. The releasing device is simply connected to the push rod chamber’s outlet. When the releasing device operates and vents the push rod chamber, the Deluge Valve opens. Typical releasing devices include hydraulic manual emer- gency stations, Model F1-FTR Fixed Temperature Detectors on wet pilot lines, dry pilot actuators, and solenoid valves. Model F1-FTR Detectors perform both Deluge Valve releasing and fire detection functions with wet pilot lines. The use of a solenoid valve for Deluge Valve releasing en- ables various types of electrical fire detection devices to be used. Typical detection devices include electrical emergency pull stations, thermal detectors, and ionization or photoelectric smoke detectors. Electrical detection and releasing equipment used in Electrical Systems is described in Bulletin 700, for both deluge and preaction systems. Model DDX Deluge Valve Description 1. Rated working pressure: Valve & System - 250 psi (17.2 bar) for the 2” (50mm), 2½” (65mm), 76mm, 3” (80mm) and 8” (200mm) valve sizes and 300 psi (20,7 bar) for the 4” (100mm), 165mm and 6” (150mm) valve sizes. 2. Factory tested to a hydrostatic pressure of 500 psi (34,5 bar) for the 2” (50mm), 2½” (65mm), 76mm, 3” (80mm) and 8” (200mm) valve sizes and 600 psi (41,4 bar) for the 4” (100mm), 165mm and 6” (150mm) valve sizes. (Valve only) 3. End and trim connections: · ANSI/AWWA C606 grooved inlet and outlet Nominal Pipe Size Outlet Diameter Groove Diameter Groove Width Outlet Face to Groove 2” (50 mm) 2.375” (60mm) 2.250” (57mm) 11/32” (9.0mm) 5/8” (16mm) 2½” (65 mm) 2.875” (73mm) 2.720” (69mm) 11/32” (9.0mm) 5/8” (16mm) 76 mm 3.000” (76mm) 2.845” (72mm) 11/32” (9.0mm) 5/8” (16mm) 3” (80 mm) 3.500” (89mm) 3.344” (85mm) 11/32” (9.0mm) 5/8” (16mm) 4” (100 mm) 4.500” (114mm) 4.334” (110mm) 3/8” (9.5mm) 5/8” (16mm) 165 mm 6.500” (165mm) 6.330” (161mm) 3/8” (9.5mm) 5/8” (16mm) 6” (150 mm) 6.625” (168mm) 6.455” (164mm) 3/8” (9.5mm) 5/8” (16mm) 8” (200 mm) 8.625” (219mm) 8.441” (214mm) 7/16” (11mm) 3/4” (19mm) · Threaded openings Per ANSI B 2.1 Vail Fire & Emergency Services 11/01/16 7. Trim Shipping Weight: Trim ConÞ guration 2" (50 mm), 2½" (65 mm), 3" (80 mm) & 76 mm 4" (100 mm), 6" (150 mm), 8" (200 mm) & 165 mm Wet Pilot Deluge 31 lbs (14 kg) 37 lbs (17 kg) Dry Pilot Deluge 39 lbs (18 kg) 50 lbs (23 kg) Electric Actuation Deluge 33 lbs (15 kg) 38 lbs (17 kg) 8. Friction loss (Expressed in equivalent length of Schedule 40 pipe, based on Hazen & Williams for- mula: Valve Size: Equivalent Length: Cv C = 120 C = 100 2" (50mm) 4.4 ft (1,3 m) 3.1 ft (1,0 m) 101 2½" (65mm) 6.0 ft (1,8 m) 4.3 ft (1,3 m) 236 76mm 7.7 ft (2,3 m) 5.5 ft (1,7 m) 241 3" (80mm) 12.6 ft (3,8 m) 9.0 ft (2,7 m) 254 4" (100mm) 14 ft (4,3 m) 10 ft (3,0 m) 469 165mm 29.4 ft (9,0 m) 20.9 ft (6,4 m) 886 6" (150mm) 29.4 ft (9,0 m) 20.9 ft (6,4 m) 886 8" (200mm) 53.5 ft (16,3 m) 38.1 ft (11,6 m) 1516 9. Installation position: Vertical Trim Descriptions The trims for the Reliable Model DDX Deluge Valve are ar- ranged for rapid, easy, and compact attachment, and serve as connection points to Reliable Model C Mechanical Alarms and other devices. The available Model DDX Deluge Valve trim sets are: · Wet Pilot Trim · Dry Pilot Trim · Electric Actuation Trim The Wet Pilot Trim (see Fig. 4 or Fig. 5) is used when wet pilot sprinklers or hydraulic manual emergency pull boxes are used for detection and releasing. This trim set provides a one and one quarter main drain for 2” (50mm), 2½” (65mm), 76mm & 3” (80mm) valve sizes or a two inch main drain for 4” (100mm), 6” (150mm), 165mm & 8” (200mm) valve sizes, alarm test, supply pressure gauge, push rod chamber pressure gauge, push rod chamber supply connections, Model B Hydraulic Manual Emer- gency Station, and a connection for releasing devices. The Dry Pilot Trim (see Fig. 6 or Fig. 7) is used when dry pilot sprinklers are used as the fire detection means. This trim set includes the Model LP Dry Pilot Line Actuator, air and wa- ter pressure gauges, low air pressure switch (for Dry Pilot Line), air pressure relief valve, connections for the air supply and pilot sprinkler lines, a one and one quarter main drain for 2” (50mm), 2½” (65mm), 76mm & 3” (80mm) valve sizes or a two inch main drain for 4” (100mm), 6” (150mm), 165mm & 8” (200mm) valve sizes, alarm test, push rod chamber connections, push rod chamber pressure gauge, and the Model B Hydraulic Manual Emergency Station. Table A provides the recommended air pressure when the dry pilot trim set is used as the actuation means. · Flange Dimensions Flange Type: Nominal Pipe Size Bolt Circle Diameter Bolt Hole Diameter Flange Outside Diameter Flange Thickness Number of Bolts AMSE B16.5 Class 150 4” (100mm) 7½” (191mm) ¾” (19mm) 9” (229mm) 15/16” (24mm) 8 ISO 7005-2 PN16 4” (100mm) 73/32” (180mm) ¾” (19mm) 9” (229mm) 15/16” (24mm) 8 AMSE B16.5 Class 150 6” (150mm) 9½” (241mm) 7/8” (22mm) 11” (279mm) 15/16” (24mm) 8 ISO 7005-2 PN16 6” (150mm) 97/16” (240mm) 29/32” (23mm) 11” (279mm) 15/16” (24mm) 8 AMSE B16.5 Class 150 8” (200mm) 11¾” (298mm) 7/8” (22mm) 13½” (343mm) 1” (25.4mm) 8 ISO 7005-2 PN16 8” (200mm) 115/8” (295mm) 29/32” (23mm) 13½” (343mm) 1” (25.4mm) 12 4. Valve Exterior’s Color: Valve Size Color 2” (50 mm) Black or Red 2½” (65 mm) Black or Red 76 mm Red 3” (80 mm) Black or Red 4” (100 mm) Black or Red 165 mm Red 6” (150 mm) Black or Red 8” (200 mm) Black or Red 5. Face to face dimensions: Valve Size: End Connection: End to End: 2" (50mm), 2½" (65mm), 76mm & 3" (80mm) Groove/ Groove 12½" (318mm) 4" (100mm) Groove/ Groove 14" (356mm) Flange/ Groove 16" (406mm) Flange/ Flange 16" (406mm) 6" (150mm) & 165mm Groove/ Groove 16" (406mm) Flange/ Groove 19" (483mm) Flange/ Flange 19" (483mm) 8" (200mm) Groove/ Groove 193/8” (492mm) Flange/ Flange 21¼" (540mm) 6. Valve Shipping Weight: Valve Size: End Connection: Weight: 2" (50mm), 2½" (65mm), 76mm & 3" (80mm) Groove/ Groove 34 lbs (15 kg) 4" (100mm) Groove/ Groove 64 lbs (29 kg Flange/ Groove 79 lbs (36 kg) Flange/ Flange 92 lbs (42 kg) 6" (150mm) & 165mm Groove/ Groove 95 lbs (43 kg) Flange/ Groove 122 lbs (56 kg) Flange/ Flange 138 lbs (69 kg) 8" (200mm) Groove/ Groove 148 lbs (67 kg) Flange/ Flange 197 lbs (90 kg) 4. Vail Fire & Emergency Services 11/01/16 5. Fig. 4 Vail Fire & Emergency Services 11/01/16 6. Fig. 5 Vail Fire & Emergency Services 11/01/16 7. Fig. 6 Vail Fire & Emergency Services 11/01/16 8. Table A Water Pressure psi (bar) Pneumatic Pressure to be Pumped into Sprinkler System psi (bar) Maximum Not Less Than Not More Than 20 (1.4) 10 (.7) 14 (1.0) 50 (3.4) 12 (.8) 16 (1.1) 75 (5.2) 13 (.9) 17 (1.2) 100 (6.9) 15 (1.) 19 (1.3) 125 (8.6) 16 (1.1) 20 (1.4) 150 (10.3) 17 (1.2) 21 (1.4) 175 (12.1) 18 (1.2) 22 (1.5) 200 (13.8) 19 (1.3) 23 (1.6) 225 (15.5) 21 (1.4) 25 (1.7) 250 (17.2) 22 (1.5) 26 (1.8) 275 (19.) 23 (1.6) 27 (1.9) 300 (20.7) 24 (1.7) 28 (1.9) *Note: During system set-up, a higher pneumatic pressure may be required in order to properly set the Model LP Dry Valve Ac- tuator. The Electric Actuation Trim (see Fig. 8 or Fig. 9) is used when electric detection and releasing are desired. This trim set includes a solenoid valve (175 psi (12,1 bar) or 300 psi (20,7 bar) rated), one and one quarter main drain for 2” (50mm), 2½” (65mm), 76mm & 3” (80mm) valve sizes or a two inch main drain for 4” (100mm), 6” (150mm), 165mm & 8” (200mm) valve sizes, alarm test supply pressure gauge, push rod chamber pressure gauge, push rod chamber supply connections, and the Model B Hydraulic Manual Emergency Station. Detailed description of electrical operation can be found in Bulletins 707 and 708. The Model B Hydraulic Manual Emergency Station is a stan- dard item in all trim sets. However, the Model A Hydraulic Manu- al Emergency Station, described in Bulletin 506, is also available as an option. All Model DDX Deluge Valves are listed by Underwriters Laboratories, Inc, and certified by UL for Canada (cULus) and certified by Factory Mutual Approvals, only when used with the valve manufacturer’s trim sets. Ordering Information Specify: · Valve Model & Size Valve Part Numbers Valve Size & End Connection Flange Type Color Reliable Part Number 2” (50mm) Grv/Grv N/A Black 6103022000 Red 6103022001 2½” (65mm) Grv/Grv N/A Black 6103022500 Red 6103022501 3” (80mm) Grv/Grv N/A Black 6103030000 Red 6103030001 76mm Grv/Grv N/A Red 6103027600 4” (100mm) Grv/Grv N/A Black 6103040026 Red 6103040030 4” (100mm) Flg/Grv ASME Class 150 Black 6103040044 ASME Class 150 Red 6103040046 ISO PN16 Red 6103040048 4” (100mm) Flg/Flg ASME Class 150 Black 6103040045 ASME Class 150 Red 6103040047 ISO PN16 Red 6103040049 6” (168mm) Grv/Grv N/A Black 6103060024 Red 6103060030 6” (168mm) Flg/Grv ASME Class 150 Black 6103060045 ASME Class 150 Red 6103060047 ISO PN16 Red 6103060049 6” (168mm) Flg/Flg ASME Class 150 Black 6103060046 ASME Class 150 Red 6103060048 ISO PN16 Red 6103060050 165mm Grv/Grv N/A Red 6103060028 165mm Flg/Grv ASME Class 150 Red 6103060051 ISO PN16 Red 6103060052 8” (200mm) Grv/Grv N/A Black 6103080001 Red 6103080003 8” (200mm) Flg/Flg ASME Class 150 Black 6103080016 ASME Class 150 Red 6103080018 ISO PN16 Red 6103080020 Vail Fire & Emergency Services 11/01/16 · Trim — Wet Pilot Trim, Dry Pilot Trim, or Electric Actuation Trim. Each trim set is available in individual parts, in time-saving, segmentally assembled kit forms, or fully assembled to the Model DDX Deluge Valve with or without a control valve). The Electric Actuation trim is available with a 175 psi (12,1 bar) or 300 psi (20,7 bar) rated solenoid valve. Wet Pilot Line Deluge Trim Part Numbers Valve Size & End Connection Trim ConÞ gurations Flange Type Color Individual Parts (Model DDX Valve Sold Seperately) Segmentally Assembled (Model DDX Valve Sold Seperately) Fully Assembled to Model DDX Valve w/o Control Valve Fully Assembled to Model DDX Valve w/ Control Valve 2” (50mm) Grv/Grv N/A Black 6503002004 6503002005 6505020001 6505020000 Red 6505A20001 6505A20000 2½” (65mm) Grv/Grv N/A Black 6505022501 6505022500 Red 6505A22501 6505A22500 3” (80mm) Grv/Grv N/A Black 6505030001 6505030000 Red 6505A30001 6505A30000 76mm Grv/Grv N/A Red 6505A27601 N/A 4” (100mm) Grv/Grv N/A Black 6503001002 6503001003 6505040201 6505040200 Red 6505A40201 6505A40200 4” (100mm) Flg/Grv ASME Class 150 Black 6505043201 N/A ASME Class 150 Red 6505A43201 ISO PN16 Red 6505A44201 4” (100mm) Flg/Flg ASME Class 150 Black 6505047201 N/A ASME Class 150 Red 6505A47201 ISO PN16 Red 6505A48201 6” (168mm) Grv/Grv N/A Black 6505060201 6505060200 Red 6505A60201 6505A60200 6” (168mm) Flg/Grv ASME Class 150 Black 6505063201 N/A ASME Class 150 Red 6505A63201 ISO PN16 Red 6505A64201 6” (168mm) Flg/Flg ASME Class 150 Black 6505067201 N/A ASME Class 150 Red 6505A67201 ISO PN16 Red 6505A68201 165mm Grv/Grv N/A Red 6505A65201 N/A 165mm Flg/Grv ASME Class 150 Red 6505A66201 N/A ISO PN16 Red 6505A69201 8” (200mm) Grv/Grv N/A Black 6505080201 6505080200 Red 6505A80201 6505A80200 8” (200mm) Flg/Flg ASME Class 150 Black 6505087201 N/A ASME Class 150 Red 6505A87201 ISO PN16 Red 6505A88201 Note: For metric installations, a 1¼” NPT x R1¼. ISO 7/1 x Close Nipple (Reliable P/N 98543403) or a 2” NPT x R2. ISO 7/1 x Close Nipple (Reliable P/N 98543401) is sold separately as an adapter for the single drain outlet of the trims. · Additional equipment — Air compressors, electric detection, actuation equipment, and mechanical sprinkler alarms must be ordered separately. These devices are described in Bulletin 700. 9. Vail Fire & Emergency Services 11/01/16 Dry Pilot Deluge Trim Part Numbers Valve Size & End Connection Trim ConÞ gurations Flange Type Color Individual Parts (Model DDX Valve Sold Seperately) Segmentally Assembled (Model DDX Valve Sold Seperately) Fully Assembled to Model DDX Valve w/o Control Valve Fully Assembled to Model DDX Valve w/ Control Valve 2” (50mm) Grv/Grv N/A Black 6503002108 6503002109 6505020006 6505020005 Red 6505A20006 6505A20005 2½” (65mm) Grv/Grv N/A Black 6505022506 6505022505 Red 6505A22506 6505A22505 3” (80mm) Grv/Grv N/A Black 6505030006 6505030005 Red 6505A30006 6505A30005 76mm Grv/Grv N/A Red 6505A27606 N/A 4” (100mm) Grv/Grv N/A Black 6503001107 6503001108 6505040206 6505040205 Red 6505A40206 6505A40205 4” (100mm) Flg/Grv ASME Class 150 Black 6505043206 N/A ASME Class 150 Red 6505A43206 ISO PN16 Red 6505A44206 4” (100mm) Flg/Flg ASME Class 150 Black 6505047206 N/A ASME Class 150 Red 6505A47206 ISO PN16 Red 6505A48206 6” (168mm) Grv/Grv N/A Black 6505060206 6505060205 Red 6505A60206 6505A60205 6” (168mm) Flg/Grv ASME Class 150 Black 6505063206 N/A ASME Class 150 Red 6505A63206 ISO PN16 Red 6505A64206 6” (168mm) Flg/Flg ASME Class 150 Black 6505067206 N/A ASME Class 150 Red 6505A67206 ISO PN16 Red 6505A68206 165mm Grv/Grv N/A Red 6505A65206 N/A 165mm Flg/Grv ASME Class 150 Red 6505A66206 N/A ISO PN16 Red 6505A69206 8” (200mm) Grv/Grv N/A Black 6505080206 6505080205 Red 6505A80206 6505A80205 8” (200mm) Flg/Flg ASME Class 150 Black 6505087206 N/A ASME Class 150 Red 6505A87206 ISO PN16 Red 6505A88206 2” (50mm) Grv/Grv N/A Black 6503002112 6503002113 6505020008 6505020007 Red 6505A20008 6505A20007 2½” (65mm) Grv/Grv N/A Black 6505022508 6505022507 Red 6505A22508 6505A22507 3” (80mm) Grv/Grv N/A Black 6505030008 6505030007 Red 6505A30008 6505A30007 76mm Grv/Grv N/A Red 6505A27608 N/A 4” (100mm) Grv/Grv N/A Black 6503001109 6503001110 6505040209 6505040208 Red 6505A40209 6505A40208 4” (100mm) Flg/Grv ASME Class 150 Black 6505043209 N/A ASME Class 150 Red 6505A43209 ISO PN16 Red 6505A44209 4” (100mm) Flg/Flg ASME Class 150 Black 6505047209 N/A ASME Class 150 Red 6505A47209 ISO PN16 Red 6505A48209 6” (168mm) Grv/Grv N/A Black 6505060209 6505060208 Red 6505A60209 6505A60208 6” (168mm) Flg/Grv ASME Class 150 Black 6505063209 N/A ASME Class 150 Red 6505A63209 ISO PN16 Red 6505A64209 6” (168mm) Flg/Flg ASME Class 150 Black 6505067209 N/A ASME Class 150 Red 6505A67209 ISO PN16 Red 6505A68209 165mm Grv/Grv N/A Red 6505A65207 N/A 165mm Flg/Grv ASME Class 150 Red 6505A66207 N/A ISO PN16 Red 6505A69207 8” (200mm) Grv/Grv N/A Black 6505080209 6505080208 Red 6505A80209 6505A80208 8” (200mm) Flg/Flg ASME Class 150 Black 6505087209 N/A ASME Class 150 Red 6505A87209 ISO PN16 Red 6505A88209 { { 10. UL/FM ULC Vail Fire & Emergency Services 11/01/16 Electric Actuation Deluge (Explosion Proof Solenoid Available Upon Request) Trim Part Numbers Valve Size & End Connection Trim ConÞ gurations Flange Type Color Individual Parts (Model DDX Valve Sold Seperately) Segmentally Assembled (Model DDX Valve Sold Seperately) Fully Assembled to Model DDX Valve w/o Control Valve Fully Assembled to Model DDX Valve w/ Control Valve 2” (50mm) Grv/Grv N/A Black 6503002507 6503002508 6505020011 6505020010 Red 6505A20011 6505A20010 2½” (65mm) Grv/Grv N/A Black 6505022511 6505022510 Red 6505A22511 6505A22510 3” (80mm) Grv/Grv N/A Black 6505030011 6505030010 Red 6505A30011 6505A30010 76mm Grv/Grv N/A Red 6505A27611 N/A 4” (100mm) Grv/Grv N/A Black 6503001505 6503001507 6505040211 6505040210 Red 6505A40211 6505A40210 4” (100mm) Flg/Grv ASME Class 150 Black 6505043211 N/A ASME Class 150 Red 6505A43211 ISO PN16 Red 6505A44211 4” (100mm) Flg/Flg ASME Class 150 Black 6505047211 N/A ASME Class 150 Red 6505A47211 ISO PN16 Red 6505A48211 6” (168mm) Grv/Grv N/A Black 6505060211 6505060210 Red 6505A60211 6505A60210 6” (168mm) Flg/Grv ASME Class 150 Black 6505063211 N/A ASME Class 150 Red 6505A63211 ISO PN16 Red 6505A64211 6” (168mm) Flg/Flg ASME Class 150 Black 6505067211 N/A ASME Class 150 Red 6505A67211 ISO PN16 Red 6505A68211 165mm Grv/Grv N/A Red 6505A65211 N/A 165mm Flg/Grv ASME Class 150 Red 6505A66211 N/A ISO PN16 Red 6505A69211 8” (200mm) Grv/Grv N/A Black 6505080211 6505080210 Red 6505A80211 6505A80210 8” (200mm) Flg/Flg ASME Class 150 Black 6505087211 N/A ASME Class 150 Red 6505A87211 ISO PN16 Red 6505A88211 2” (50mm) Grv/Grv N/A Black 6503002511 6503002512 6505020016 6505020015 Red 6505A20016 6505A20015 2½” (65mm) Grv/Grv N/A Black 6505022516 6505022515 Red 6505A22516 6505A22515 3” (80mm) Grv/Grv N/A Black 6505030016 6505030015 Red 6505A30016 6505A30015 76mm Grv/Grv N/A Red 6505A27616 N/A 4” (100mm) Grv/Grv N/A Black 6503001506 6503001508 6505040216 6505040215 Red 6505A40216 6505A40215 4” (100mm) Flg/Grv ASME Class 150 Black 6505043216 N/A ASME Class 150 Red 6505A43216 ISO PN16 Red 6505A44216 4” (100mm) Flg/Flg ASME Class 150 Black 6505047216 N/A ASME Class 150 Red 6505A47216 ISO PN16 Red 6505A48216 6” (168mm) Grv/Grv N/A Black 6505060216 6505060215 Red 6505A60216 6505A60215 6” (168mm) Flg/Grv ASME Class 150 Black 6505063216 N/A ASME Class 150 Red 6505A63216 ISO PN16 Red 6505A64216 6” (168mm) Flg/Flg ASME Class 150 Black 6505067216 N/A ASME Class 150 Red 6505A67216 ISO PN16 Red 6505A68216 165mm Grv/Grv N/A Red 6505A65216 N/A 165mm Flg/Grv ASME Class 150 Red 6505A66216 N/A ISO PN16 Red 6505A69216 8” (200mm) Grv/Grv N/A Black 6505080216 6505080215 Red 6505A80216 6505A80215 8” (200mm) Flg/Flg ASME Class 150 Black 6505087216 N/A ASME Class 150 Red 6505A87216 ISO PN16 Red 6505A88216 11. 175 PSI 250 PSI { {Vail Fire & Emergency Services 11/01/16 Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 06/15 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. P/N 9999970438 Nominal Pipe Size Installation Dimensions in Inches (mm) A B C D* D** D*** D**** E F G H J K L M N P Q R 2” (50 mm) 8 (203) 7 (178) 9½ (241) 12½ (318) 21¼ (540) N/A N/A 31 (787) 25 (635) 32½ (826) 6 (152) 11¾ (298) 4¼ (108) 5½ (140) 11 (279) 3 (76) 4½ (114) 9¼ (235) 10¼ (260) 2½” (65 mm), 3” (80 mm) & 76 mm 8 (203) 7 (178) 9½ (241) 12½ (318) 22 (559) N/A N/A 31 (787) 25 (635) 32½ (826) 6 (152) 11¾ (298) 4¼ (108) 5½ (140) 11 (279) 3 (76) 4½ (114) 9¼ (235) 10¼ (260) 4” (100 mm) 7¼ (184) 7½ (191) 10 (254) 14 (356) 24¼ (616) 16 (406) 16 (406) 31 (787) 25 (635) 32½ (826) 7½ (191) 13¼ (337) 5½ (140) 8¼ (210) 13½ (343) 5 (127) 6¾ (171) 11¾ (298) 11¾ (298) 6” (150 mm) & 165 mm 7¼ (184) 8½ (215) 11 (280) 16 (406) 27½ (699) 19 (483) 19 (483) 33½ (851) 27½ (699) 35 (889) 8 (203) 13¾ (349) 5½ (140) 8¼ (210) 13¾ (349) 4¾ (121) 6½ (165) 12 (305) 12¼ (311) 8” (200 mm) 7¼ (184) 9¼ (235) 11½ (292) 193/8 (492) 30¼ (768) N/A 21¼ (540) 33¾ (857) 27¾ (705) 35¼ (895) 9 (229) 14¾ (375) 5½ (140) 8¼ (210) 14½ (368) 3½ (89) 5¼ (133) 12¾ (324) 13¼ (337) D* is total takeout for Fully Assembled to Grv/Grv DDX Valve w/o Control Valve Configurations D** is total takeout for Fully Assembled to Grv/Grv DDX Valve w/ Control Valve Configurations D*** is total takeout for Fully Assembled to Flg/Grv DDX Valve w/o Control Valve Configurations D**** is total takeout for Fully Assembled to Flg/Flg DDX Valve w/o Control Valve Configurations Vail Fire & Emergency Services 11/01/16 Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Bulletin 043 Rev. A Bulletin 043 Rev A Model G5-80, G5-56, G5-42, G5-28 Quick Response “Sealing” Concealed Automatic Sprinklers A Quick Response “Sealing” Concealed Sprinkler with a ¾” (19mm) Adjustment and a Dust Tight Seal Features 1. Cover plate with gasket seal for Quick Response may be assembled to a G5-80, G5-56, G5-42, and G5-28 Sprinklers for dust free environments. 2. A Total adjustment of ¾” (19mm) provided by stan- dard inlet version. 3. White “Sealing” Concealer Gasket is Listed with G4 Cover Plate available in white paint and Chrome. Other cover plate finishes and colors are available. Consult with factory. 4. Ordinary and intermediate temperature rating avail- able. 5. The cover plate does not require clips or springs. Approvals & Listings Underwriters Laboratories, Inc. and Certified for Canada (cULus) Note: Approvals are for light and ordinary hazard, except for small ori- fice sprinkler which are limited to light hazard occupancies. The cup and skirt are fabricated from plated steel and are intended for interior non-corrosive applications US. Patent No. 6,554,077 Applications The Model G5-80, G5-56, G5-42, G5-28 with seal provides fire protection for dust free environments while offering an at- tractive appearance and ¾” (19mm) adjustment for easy instal- lation. The small diameter gasketed cover plate assembly is easily and positively attached and blends into the ceiling, con- cealing the most dependable fire protection available, an auto- matic sprinkler system. The Model G5-80, G5-56, G5-42, G5-28 with a gasketed cover plate assembly is designed solely for use in dust free environments such as a clean room. The Model G5- 80, G5-56, G5-42, G5-28 “Sealing” concealed sprinklers can eliminate the need for precise cutting of drop nipples. The gasketed cover plate assembly can be adjusted with- out tools to fit accurately on the ceiling. The fire protection system need not be shut down to adjust or remove the gasketed cover plate assembly. Product Description Model G5-80, G5-56, G5-42, G5-28 “Sealing” Con- cealed uses proven solder link fusible elements in a stan- dard style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat gasketed cover plate. This threaded engagement pro- vides ¾” (19mm) of cover adjustment to the threaded cup. The flat cover plate is attached to the skirt using the same ordinary temperature classification solder that is used in sprinklers. This results in ordinary temperature rated cover plates concealing either ordinary temperature sprinklers or intermediate temperature sprinklers which can be in- stalled in 150°F environments. When the ceiling tempera- ture rises, the solder holding the flat cover plate fuses and the cover plate is released, exposing the sprinkler inside the cup to the rising ambient temperature. The subsequent fusing of the solder element in the sprin- kler opens the waterway and causes the deflector to drop into position to distribute the discharging water. Any se- cure engagement between the gasket cover plate and cup will assure that the drop-down deflector is properly located below the ceiling. Cover plate & gasket are only sold as an assembly. The gasket cannot be purchased as an individual part. Vail Fire & Emergency Services 11/01/16 Installation Do not install The G5-80, G5-56, G5-42, G5-28 “Sealing” Concealed Sprinklers in ceilings which have positive pressure in the space above. • Cut a 25/8” (67mm) diameter hole in the ceiling, and in- stall the non-adjustable inlet sprinkler with the Model FC Wrench. The wrench has a socket drive which is inserted into the body of the sprinkler. When installing a sprinkler, the wrench is first positioned into the sprinkler/cup as- sembly until the wrench socket engages the body of the sprinkler. The sprinkler is then tightened into the pipe fitting. When inserting or removing the wrench from the sprinkler/ cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER/CUP ASSEMBLY. Wherever seal is needed, attach the “Sealing” Concealed gasket over the Cover plate. • If required to reassemble the gasket to the cover plate, do not glue the gasket into place or allow the gasket to overlap both the cover plate and flange of the skirt. • The gasket and cover plate of the “Sealing” sprinklers are not to be interchanged with other models of concealed sprinklers. • Paint or any other coating over the factory finish on cover plates will void all approvals and warranties. Standard Temperatures ClassiÞ cation Sprinkler Cover Plate Max. Ambient Temp. Ordinary 165°F/74°C 135°F/57°C 100°F/38°C Intermediate 212°F/100°C 165°F/74°C 150°F/66°C Maximum Working Pressure 175 psi (12 bar) 100% Factory tested Hydrostatically to 500 psi (34.5 bar) Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 11/14 P/N 9999970435 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Technical Installation Data Sprinkler Model Sprinkler Inlet Total Adjustment Nominal OriÞ ce Nominal K Factor Thread Sprinkler IdentiÞ cation (SIN) US Metric G5-80 Non Adjustable ¾” (19mm) 17/32” (15mm) 8.0 115 ¾” NPT (R¾) RA3412 G5-56 Non Adjustable ¾” (19mm) ½” (15mm) 5.6 80 ½” NPT (R½) RA3415 G5-42 Non Adjustable ¾” (19mm) 7/16” (10mm) 4.2 60 ½” NPT (R½) RA3413 G5-28 Non Adjustable ¾” (19mm) 3/8” (10mm) 2.8 40 ½” NPT (R½) RA3411 Cover Plate: 3/4” [19.05mm] Adjustment Figure 1 Notice FOR USE AS A REPLACEMENT OF MODEL G4A SPRINKLERS (See Figure 2) NOTE: 1. Testing has shown that use of a “nipple extension” will not affect the listing of the sprinkler. 2. For RETROFIT installations, per NFPA 13 (2010) section 8.15.19.4, “which allows the use of nipples as the same pipe thread size as the existing outlet when revamping existing systems”. 3. Do not exceed 8-18 ft.lbs (10.8 - 29.4 N.m) of torque during install. Ordering Information 1. Sprinkler Model 2. Temperature Rating 3. Nominal Orifice 4. Inlet Type 5. Cover Plate Assembly Finish 6. Gasket Cover Plate Finishes(1) Standard Finishes White Paint Chrome (1) Other Finishes and colors are available on special orders. Consult factory for detail. Gasket Color • White only Cover Plate: 3/4”(19.05mm) Adjustment Figure 2 CAUTION: Cover plate with gasket are not interchangeable between Quick Response and Standard Response Models. Vail Fire & Emergency Services 11/01/16 Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F1FR Series Quick Response Standard Spray Bulletin 014 Rev. L Bulletin 014 Rev. L Model F1FR56 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model F1FR56 Recessed Sprinkler Types Standard Pendent/F1/F2/FP Horizontal Sidewall Model F1FR56 Concealed Sprinkler Types Standard Pendent Model F1FR42, F1FRXLH & F1FR28 Sprinkler Types Standard Upright Standard Pendent Model F1FR42, F1FRXLH & F1FR28 Recessed Sprinkler Types Standard Pendent Model F1FR56LL & F1FR42LL Low Lead Sprinkler Types* Standard Pendent Less than 0.25% Lead Content Listing & Approvals 1. Underwriters Laboratories Inc. and Certified for Canada (cULus). 2. Factory Mutual Approvals (FM) 3. Loss Prevention Council (LPCB, UK) 4. VdS Schadenverhütung GmbH 5. *NSF Certified to NSF/ANSi Standard 61 Annex G 6. EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Product Description Reliable Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series Sprinklers are quick response sprinklers which combine the durability of a standard sprin- kler with the attractive low profile of a decorative sprinkler. The Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1FR56, F1FR56LL, Pendent Conventional Recessed Pendent/F1/F2 Upright Vertical Sidewall Horizontal Sidewall Recessed Horizontal Sidewall Recessed Pendent/FP Concealed Pendent XLH Upright XLH Pendent XLH Recessed Pendent F1/F2 XLH Recessed Pendent FP F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series sprinklers to apply wa- ter to a fire much faster than standard sprinklers of the same temperature rat- ing. The glass bulb consists of an accu- rately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Vail Fire & Emergency Services 11/01/16 2. Technical data: Models Discharge CoefÞ cient Response Thread Size Max. Working Pressure Min. Working Pressure Temperature Rating Finish F1FR56 **F1FR56LL(1) K 5.6 Quick Response 1/2” NPT (R1/2) 175 PSI 7 PSI See “Temperature Ratings” Table. See “Finish Table” F1FR42 **F1FR42LL(1) F1FRXLH K 4.2 F1FR28 K 2.8 (1) Low Lead Sprinklers available only with Temperature Rating 200°F/93°C Material Data: Frame Deß ector Load Screw *Pintle Cup Washer Bulb DZR Brass QM Brass **Low Lead Brass CDA Alloy 260, CDA Alloy 220 or CDA Alloy510 CDA Alloy 360 or CDA Alloy 544 CDA Alloy 360 or CDA Alloy 544 CDA Alloy 651 or CDA Alloy 693 Nickel Alloy 440 or Alloy 360 coated with PTFE Adhesive Tape Glass Application Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard re- sponse sprinklers should not be intermixed. Model F1FR42, F1FRXLH Upright Vail Fire & Emergency Services 11/01/16 Pendent Conventional Upright Model F1FR56, Upright, Pendent & Conventional Sprinklers Model F1FR42, F1FRXLH & F1FR28 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal OriÞ ce Thread Nominal K Factor Sprinkler Approval Sprinkler IdentiÞ cation Number (SIN) Size US Metric Height Organization Upright Pendent Standard-Upright (SSU) and Pendent Deflectors Marked to Indicate Position 1/2” (15mm) (1) 1/2” NPT (R1/2) 5.6 80 2.25” (57mm) 1, 2, 3, 4, 6 RA1425(1)(2)(3)(4) RA1414(1)(2)(3)(4) 7/16” (10mm) 1/2” NPT (R1/2) 4.2 60 2.25” (57mm) 1 RA1423(1)(4) RA1413(4) 3/8” (10mm) 1/2” NPT (R1/2) 2.8 40 2.25” (57mm) 1 RA1421(1)(4) RA1411(4) Conventional-Install in Upright or Pendent Position 15mm (1) 1/2” NPT (R1/2) 5.6 80 57mm 3, 4, 6 RA1475(3) (1) cULus listed corrosion resistant (Polyester coated) sprinkler. (2) Polyester coated FM approved sprinkler. (3) Polyester coated LPCB & VdS approved sprinkler RA1425, RA1414 & RA1475. (4) Electroless Nickel PTFE (Teflon®)* Plated - cULus listed Corrosion Resistant 3. Model F1FR56LL & F1FR42LL Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal OriÞ ce Thread Nominal K Factor Sprinkler Approval Sprinkler IdentiÞ cation Number (SIN) Size US Metric Height Organization Pendent Standard-Pendent Deflectors Marked to Indicate Position 1/2” (15mm) (1) 1/2” NPT (R1/2) 5.6 80 2.25” (57mm) 1, 5 RA1415 7/16” (11mm) 1/2” NPT (R1/2) 4.2 60 2.25” (57mm) 1, 5 RA1410 (1) cULus listed corrosion resistant (Polyester coated) sprinkler. *DuPont Registered Trademark Vail Fire & Emergency Services 11/01/16 Model F1FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal OriÞ ce Thread Size Nominal K Factor Sprinkler Height Approval Organizations Sprinkler IdentiÞ cation Numbers (SIN) US Metric ½” (15mm) ½” NPT (R1/2) 5.6 80 2.25” (57mm) 1, 2, 3 RA1485(2)(3) 15mm ½” NPT (R1/2) 5.6 80 2.25” (57mm) 3(1) (1) LPC Approval is for pendent position only. (2) cULus Listed corrosion resistant (Polyester coated) sprinkler. (3) Electroless Nickel PTFE (Teflon®)* Plated - cULus listed Corrosion Resistant Sprinkler Type Deß ector to Ceiling Distance (Min. - Max.) Upright 4” (102mm) - 12” (305mm) Pendent 4” (102mm) - 12” (305mm) Vertical Sidewall Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 F1 or F2 Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 FP Model F1FR56, F1FR42, F1FRXLH & F1FR28 Quick Response Recessed Pendent Sprinkler(1) Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal OriÞ ce Thread Size K Factor Sprinkler Height Sprinkler IdentiÞ cation Number (SIN) US Metric 1/2” (15mm) 1/2” NPT(R½) 5.6 80 2.25” (57mm) RA1414 7/16” (10mm) 1/2” NPT (R1/2) 4.2 60 2.25” (57mm) RA1413 3/8” (10mm) 1/2” NPT (R1/2) 2.8 40 2.25” (57mm) RA1411 (1) Refer to escutcheon data table for approvals & dimensions Model F1FR56LL & F1FR42LL Quick Response Recessed Pendent Sprinkler(1) Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal OriÞ ce Thread Size K Factor Sprinkler Height Sprinkler IdentiÞ cation Number (SIN) US Metric 1/2” (15mm) 1/2” NPT(R½) 5.6 80 2.25” (57mm) RA1415 7/16” (10mm) 1/2” NPT (R1/2) 4.2 60 2.25” (57mm) RA1410 (1) Refer to escutcheon data table for approvals & dimensions 4. *DuPont Registered Trademark Vail Fire & Emergency Services 11/01/16 5. Model F1FR56 Quick Response Horizontal Sidewall Sprinkler Deß ector: HSW Installation Wrench: Model D Sprinkler Wrench Installation Data: Horizontal Sidewall Nominal OriÞ ce Thread Size Nominal K Factor Sprinkler Height Approval Organizations and Type of Approval Sprinkler IdentiÞ cation Numbers (SIN) US Metric Light Hazard Ordinary Hazard ½” (15mm) ½” NPT (R1/2) 5.6 80 2.63” (67mm) 1, 2 1 RA1435(1)(2)(3) (1) cULus Listed corrosion resistant (Polyester coated) sprinkler. (2) Polyester coated FM approved sprinkler. (3) Electroless Nickel PTFE (Teflon®)* Plated - cULus listed Corrosion Resistant Horizontal Sidewall Note: For Recessed HSW Sprinklers use installation wrench GFR2. cULus permits use with F1, F2 or FP escutcheons for “Light Hazard” only. While FM limits use for the same hazard with the F2 escutcheon only. Model F1FR56 Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: Nominal OriÞ ce “K” Factor Thread Size Model Temp. Rating Max. Ambient Temp Bulb Color Approvals Sprinkler IdentiÞ cation Number(SIN) US Metric Sprinkler Cover ½” (15mm) 5.6 80 ½” NPT F1FR 135°F/57°C 135°F/57°C 100°F/38°C Orange 1 RA1414 ½” (15mm) 5.6 80 ½” NPT F1FR 155°F/68°C 135°F/57°C 100°F/38°C Red 1, 4(1), 6 RA1414 ½” (15mm) 5.6 80 ½” NPT F1FR 175°F/79°C 165°F/74°C 100°F/38°C Yellow 1 RA1414 ½” (15mm) 5.6 80 ½” NPT F1FR 200°F/93°C 165°F/74°C 150°F/65°C Green 1 RA1414 (1) For VdS only = 155°F/68°C Norbulb and 1/2” [12,7mm] adjustment. Model F1FR56LL Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: Nominal OriÞ ce “K” Factor Thread Size Model Temp. Rating Max. Ambient Temp Bulb Color Approvals Sprinkler Identi Þ cation Number(SIN) US Metric Sprinkler Cover ½” (15mm) 5.6 80 ½” NPT F1FR56LL 200°F/93°C 165°F/74°C 150°F/65°C Green 1, 5 RA1414 *DuPont Registered Trademark Vail Fire & Emergency Services 11/01/16 Installation Aid A protective cap is included for use during installation. Important: The F1FR56 Sprinkler with Model CCP cover plate is not an FM Approved combination. Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Quick Response Sprin- klers are to be installed as shown. The Model F1 or F2 Es- cutcheons illustrated are the only recessed escutcheons to be used with the Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Sprinklers. The use of any other recessed escutcheon will void all approvals and ne- gate all warranties. When installing Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Sprinklers, use the Model D Sprinkler Wrench. Use the Model GFR2 Wrench for install- ing F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent Sprinklers. Any other type of wrench may damage these sprinklers. NOTE: A leak tight ½” NPT (R1/2) sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. The Models F1FR56/CCP & F1FR56LL/CCP Concealed Sprinkler use the ½” orifice, ½” NPT (R1/2), Model F1FR56 & F1FR56LL Pendent Sprinkler with a threaded Model CCP cup which is factory attached to the sprinklers. The Model F1FR56 Pndent is available in temperature rating of 135°F (57°C), 155°F (68°C), 175°F (79°C) or 200°F (93°C). The Model F1FR56LL Pendent is available only in a rating of 200°F (93°C). The concealed sprinkler assemblies are com- pleted by the installation of the attractive low profile Model CCP push on cover plate assembly, rated 135°F (57°C) or 165°F (74°C) for the F1FR56 and 165°F (74°C) for the FIFR56 LL. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded en- gagement. A choice of two cover plate assemblies provide either 1/2” (13mm) or 5/8” (8mm) of cover adjustment, Do not install these sprinklers in ceiling which have positive pressure in the space above. After a 25/8” (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model RC1 Wrench. A Teflon* based thread sealant should be applied to the sprin- kler threads only. The Model RC1 Wrench is then used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be tak- en to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER. The cover plate is then pushed onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impedi- ment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any other concealed cover plate/cup assembly with the Model F1FR56 Pendent Sprinkler or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifi- cally listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and in- stallation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrench- es are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PRO- TECTORS. 6. *DuPont Registered Trade Mark Figure 1 Figure 2 Vail Fire & Emergency Services 11/01/16 Temperature Ratings ClassiÞ cation Sprinkler Temperature Max. Ambient Temp. Bulb Color °C °F Ordinary Ordinary Intermediate Intermediate High (1) 57 68 79 93 141 135 155 175 200 286 100°F (38°C) 100°F (38°C) 150°F (66°C) 150°F (66°C) 225°F (107°C) Orange Red Yellow Green Blue (1) Not available for recessed sprinklers. Escutcheon Data (1) (1) SIN RA1435 – cULus permits use with F1, F2 or FP escutcheons for “light hazard” only, while FM limits use for same hazard with F2 escutcheon only. Maintenance The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH and Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Sprinklers should be inspected and the sprinkler system maintained in accor- dance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory ap- plied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of dam- aged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Recessed Pendent Vertical Sidewall Horizontal Sidewall Recessed Horizontal sidewall Concealed pendent Maximum Working Pressure 175 psi (12 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) Finishes (1) Standard Finishes Sprinkler Escutcheon Cover plate(1) Bronze Brass Chrome Chrome Plated Chrome White Polyester Plated Coated (4)(5)(6) White Painted Special Application Finishes Sprinkler Escutcheon Cover plate(1) Electroless Nickel PTFE(Teflon®)*(7) Electroless Nickel PTFE (Teflon®)*Bright Brass Bright Brass(3) Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint(2)(6) Black Paint Off White Off White(2)(6) Off White Satin Chrome Chrome Dull Chrome Dull (1) Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. (2) cULus Listed only. (3) 200°F (93°C) maximum. (4) cULus listed “corrosion resistance” applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. (5) FM Approvals finish as “Polyester coated” applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. (6) LPCB and VdS Approved finish applies only to RA1425, RA1414 and RA1475. (7) cULus listed Corrosion Resistant Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Orifice Size 4. Deflector Type 5. Temperature Rating 6. Sprinkler Finish 7. Escutcheon Type 8. Escutcheon Finish (where applicable) 9. Cover plate Model 10. Cover plate Thread size 11. Cover plate Temperature 12. Cover plate Adjustment 13. Cover plate Finish Note: When Model F1FR56 Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. 7. *DuPont Registered Trademark Vail Fire & Emergency Services 11/01/16 • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Reliable...For Complete Protection Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 09 /14 P/N 9999970300 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Vail Fire & Emergency Services 11/01/16 Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F3QR Quick Response Dry Sprinklers Bulletin 157 Rev. K Bulletin 157 Rev. K Features 1. The Model F3QR sprinkler utilizes Belleville Spring Closure Technology. Reliable is the first in the industry to produce a Quick Response Dry Concealed sprin- kler utilizing this technology. 2. Styles available • Pendent • Recessed FP Pendent • Recessed F1 Pendent • Concealed • Horizontal Sidewall • Recessed FP Horizontal Sidewall • Recessed F1 Horizontal Sidewall 3. 1½” (38mm) escutcheon adjustment on pendent sprinkler. 4. ½” (13mm) escutcheon adjustment on recessed sprin- kler with push-on/ thread-off FP Model Escutcheon ring. 5. 3/8” (9.5mm) cover plate adjustment on concealed sprinkler with push-on/ thread-off CCP Cover Plate. 6. 3/4” (19mm) escutcheon adjustment on recessed sprinkler with F1 Escutcheon. 7. Attractive appearance. Employs 3mm frangible glass bulb and galvanized nipple. 8. Lengths available to accommodate installation di- mensions from 2” - to - 48” (51mm - to - 1219mm), in ¼” (6mm) increments. See specific styles for correct “A” dimension range. 9. Available in a variety of plated and painted finishes. 10. Polyester Coated or Electroless Nickel PTFE (Teflon®)* Plated Corrosion Resistant Sprinklers. *Concealed Sprinkler is not corrosion resistance. US Patent Numbers 5,775,431 and 5,967,240. Other US Patents pending. Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Style Response Sprinkler System Type Hazard Pendent Recessed FP Pendent Recessed F1 Pendent CCP Concealed (R5714) Quick Wet Pipe Dry Pipe All Preaction Light Ordinary Horizontal Sidewall Recessed Horizontal Sidewall F1 & FP (R5734) Quick Wet Pipe Dry Pipe All Preaction Light 2. Certified by FM Approvals Style Response Sprinkler System Type Hazard Pendent Recessed F1 Pendent (R5714) Quick Wet Pipe Dry Pipe All Preaction Light Ordinary, Groups 1&2 Horizontal Sidewall Recessed F1 Horizontal Sidewall (R5734) Quick Wet Pipe Dry Pipe All Preaction Light 3. NYC MEA 258-93-E Concealed (See Fig. 4) Recessed FP Pendent (See Fig. 3) Recessed F1 Horizontal Sidewall (See Fig. 9) Horizontal Sidewall (See Fig. 6) Pendent (See Fig. 1) Recessed F1 Pendent (See Fig. 5) Recessed FP Horizontal Sidewall (See Fig. 8) Pendent / HB (See Fig. 2) Horizontal Sidewall / HB (See Fig. 7) *DuPont Registered Trademark Vail Fire & Emergency Services 11/01/16 2. Model F3QR Dry Pendent Sprinkler “A” Dim. 2” to 48” (51mm to 1219mm) in ¼” (6mm) increments Finishes(1) Sprinkler Escutcheon Electroless Nickel PTFE(Teflon®)*(4) Bronze Chrome White Polyester (2) Electroless Nickel PTFE (Teflon®)* Brass (3) Chrome White (1) Other finishes and colors are available on special order. Consult factory for details. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) Not available for HB escutcheons. (4) cULus listed Corrosion Resistant Note: The sprinkler can protrudes ¼” when escutcheon is in nominal position. Escutcheon adjustment provides -¼” (-6mm) to +1¼” (+32mm) “A” dimension adjustment range. Fig. 1 *DuPont Registered Trademark Sprinkler Guard: Model C-2 Sprinkler Installation Wrench: Model F3 Sprinkler Wrench Sprinkler IdentiÞ cation Number (SIN): R5714 Vail Fire & Emergency Services 11/01/16 Note: The sprinkler can protrudes 1¼” when escutcheon is in nominal position. Escutcheon adjustment provides -½” (-12.7mm) to +½” (+12.7mm) “A” dimension adjustment range. Fig. 2 Model F3QR Dry Pendent w/HB Escutcheon “A” Dim. 3½” to 48” (89mm to 1219mm) in ¼” (6mm) increments Standard Temperature Ratings ClassiÞ cation Sprinkler Temperature Rating Max. Ambient Temp. Bulb Color Ordinary Ordinary Intermediate (1) Intermediate High 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 100°F (38°C) 100°F (38°C) 150°F (66°C) 150°F (66°C) 225°F (107°C) Orange Red Yellow Green Blue (1) Listed and CertiÞ ed only by cULus. Electroless Nickel PTFE (Teflon®)* Plated sprinklers, escutcheons and cups are recommended for exterior applications. Sprinkler Guard: Model C-2 Sprinkler Installation Wrench: Model F3 Sprinkler Wrench Sprinkler IdentiÞ cation Number (SIN): R5714 3. *DuPont Registered Trademark Vail Fire & Emergency Services 11/01/16 Model F3QR Dry Recessed FP Pendent Sprinkler “A” Dim. 31/2” to 48” (89mm to 1219mm) in ¼” (6mm) increments Finishes(1) Sprinkler Escutcheon Electroless Nickel PTFE(Teflon®)*(3) Bronze Chrome White Polyester (2) Electroless Nickel PTFE (Teflon®)*(4) Brass Chrome White (1) Other finishes and colors are available on special order. Consult factory for details. Cup remainds unfinished. Only the escutcheon will contain desired finish. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) cULus Listed Corrosion Resistant Sprinkler. (4) Cup and Escutcheon Electroless Nickel PTFE (Teflon®)* Plated. Note: Do not install the Model F3QR Dry Recessed FP Pendent Sprinkler in ceilings which have positive pressure in space above. Fig. 3 Sprinkler Installation Wrench: Model XLO2 Sprinkler Wrench Sprinkler IdentiÞ cation Number (SIN): R5714 *DuPont Registered Trademark 4. Standard Temperature Ratings ClassiÞ cation Sprinkler Temperature Rating Max. Ambient Temp. Bulb Color Ordinary Ordinary Intermediate (1) Intermediate High (1) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 100°F (38°C) 100°F (38°C) 150°F (66°C) 150°F (66°C) 225°F (107°C) Orange Red Yellow Green Blue Sprinkler cup and FP Escutcheon fabricated of steel and recommended for interior applications. (1) Listed and CertiÞ ed only by cULus. Vail Fire & Emergency Services 11/01/16 5. Model F3QR Dry Pendent Concealed Sprinkler “A” Dim. 31/2” to 48” (89mm to 1219mm) in ¼” (6mm) increments CCP Cover Plate (1) Finishes (2) Standard Finishes Special Application Finishes Chrome Plated White Bright Brass Plated Black Plated Black Paint Off White Satin Chrome (1) Utilizes the 1/2” cover plate with 3/8” total adjustment. (2) Other finishes and colors are available on special order. Consult factory for details. Note: Do not install the Model F3QR Dry Concealed Pendent Sprinkler in ceilings which have positive pressure in the space above. Fig. 4 *DuPont Registered Trademark Sprinkler Installation Wrench: Model XLO2 Sprinkler Wrench Sprinkler IdentiÞ cation Number (SIN): R5714 Standard Temperature Ratings ClassiÞ cation Sprinkler Temperature Rating Cover Plate Temp. Rating Max. Ambient Temp. Ordinary Ordinary Intermediate (1) Intermediate High (1) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 135°F (57°C) 135°F (57°C) 165°F (74°C) 165°F (74°C) 165°F (74°C) 100°F (38°C) 100°F (38°C) 150°F (66°C) 150°F (66°C) 150°F (66°C) Sprinkler cup fabricated of steel and CCP Cover Plate fabricated of brass and recommended for interior applications. (1) Listed and CertiÞ ed only by cULus. Vail Fire & Emergency Services 11/01/16 Model F3QR Dry Recessed F1 Pendent Sprinkler “A” Dim. 31/2” to 48” (89mm to 1219mm) in ¼” (6mm) increments Finishes (1) Sprinkler Escutcheon Collar Electroless Nickel PTFE(Teflon®)*(3) Chrome White Polyester(2) Electroless Nickel PTFE (Teflon®)* Chrome White Electroless Nickel PTFE (Teflon®)* Chrome White (1) Other finishes and colors are available on special order. Consult factory for details. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) cULus Listed Corrosion Resistant Sprinkler. Standard Temperature Ratings ClassiÞ cation Sprinkler Temperature Rating Max. Ambient Temp. Bulb Color Ordinary Ordinary Intermediate (1) Intermediate High (1) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 100°F (38°C) 100°F (38°C) 150°F (66°C) 150°F (66°C) 225°F (107°C) Orange Red Yellow Green Blue (1) Listed and CertiÞ ed only by cULus. Fig. 5 Sprinkler Installation Wrench: Model XLO2 Sprinkler Wrench Sprinkler IdentiÞ cation Number (SIN): R5714 6. *DuPont Registered Trademark Vail Fire & Emergency Services 11/01/16 7. *DuPont Registered Trademark Model F3QR Dry Horizontal Sidewall Sprinkler “A” Dim. 2” to 48” (51mm to 1219mm) in ¼” (6mm) increments Finishes(1) Sprinkler Escutcheon Electroless Nickel PTFE(Teflon®)*(4) Bronze Chrome White Polyester (2) Electroless Nickel PTFE (Teflon®)* Brass (3) Chrome White (1) Other finishes and colors are available on special order. Consult factory for details. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) Not available for HB escutcheons. (4) cULus listed Corrosion Resistant Note: The sprinkler can protrudes ¼” when escutcheon is in nominal position. Escutcheon adjustment provides -¼” (-6mm) to +1¼” (+32mm) “A” dimension adjustment range. Fig. 6 Sprinkler Installation Wrench: Model F3 Sprinkler Wrench Sprinkler IdentiÞ cation Number (SIN): R5734 Vail Fire & Emergency Services 11/01/16 Note: The sprinkler can protrudes 1¼” when escutcheon is in nominal position. Escutcheon adjustment provides -½” (-12.7mm) to +½” (+12.7mm) “A” dimension adjustment range. Fig. 7 Model F3QR Dry HSW w/HB Escutcheon “A” Dim. 31/2” to 48” (89mm to 1219mm) in ¼” (6mm) increments Standard Temperature Ratings ClassiÞ cation Sprinkler Temperature Rating Max. Ambient Temp. Bulb Color Ordinary Ordinary Intermediate (1) Intermediate High (1) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 100°F (38°C) 100°F (38°C) 150°F (66°C) 150°F (66°C) 225°F (107°C) Orange Red Yellow Green Blue (1) Listed and CertiÞ ed only by cULus. Sprinkler Installation Wrench: Model F3 Sprinkler Wrench Sprinkler IdentiÞ cation Number (SIN): R5734 8. *DuPont Registered Trademark Vail Fire & Emergency Services 11/01/16 9. *DuPont Registered Trademark Model F3QR Dry Recessed FP Horizontal Sidewall Sprinkler “A” Dim. 31/2” to 48” (89mm to 1219mm) in ¼” (6mm) increments • Listed by cULus for Quick Response. Approved by FM for Standard Response. • Recessed Horizontal sidewall sprinklers are listed with cULus for installation of min. 4” (100mm) - to - max. 6” (150mm) below ceiling and ap- proved by FM for installation of min. 4” (100mm) - to - max. 12” (300mm) below ceiling. Notes: Do not install the Model F3QR Dry Recessed FP Horizontal Sidewall Sprinkler in walls which have positive pressure in their side space. Fig. 8 Sprinkler Installation Wrench: Model XLO2 Sprinkler Wrench Sprinkler IdentiÞ cation Number (SIN): R5734 Finishes (1) Sprinkler Escutcheon Electroless Nickel PTFE(Teflon®)*(3) Bronze Chrome White Polyester (2) Electroless Nickel PTFE (Teflon®)*(4) Brass Chrome White (1) Other finishes and colors are available on special order. Consult factory for details. Cup remainds unfinished. “See page 2” (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) cULus Listed Corrosion Resistant Sprinkler. (4) Sprinkler’s can and FP Escutcheon Electroless Nickel PTFE (Teflon®)* Plated recommended for exterior applications. Standard Temperature Ratings ClassiÞ cation Sprinkler Temperature Rating Max. Ambient Temp. Bulb Color Ordinary Ordinary Intermediate(1) Intermediate High (1) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 100°F (38°C) 100°F (38°C) 150°F (66°C) 150°F (66°C) 225°F (107°C) Orange Red Yellow Green Blue (1) Listed and CertiÞ ed only by cULus. Vail Fire & Emergency Services 11/01/16 *DuPont Registered Trademark “A” Dim. 31/2” to 48” (89mm to 1219mm) in ¼” (6mm) increments Finishes (1) Sprinkler Escutcheon Collar Electroless Nickel PTFE(Teflon®)*(3) Electroless Nickel PTFE (Teflon®)* Electroless Nickel PTFE (Teflon®)* Chrome Chrome Chrome White Polyester(2) White White (1) Other finishes and colors are available on special order. Consult factory for details. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) cULus Listed Corrosion Resistant Sprinkler. • Listed by cULus & Approved by FM for Quick Response. • Recessed Horizontal sidewall sprinklers are listed with cULus for installation of min. 4” (100mm) - to - max. 6” (150mm) below ceiling and approved by FM for installation of min. 4” (100mm) - to - max. 12” (300mm) below ceil- ing. Fig. 9 Model F3QR Dry Recessed F1 Horizontal Sidewall Sprinkler Sprinkler Installation Wrench: Model XLO2 Sprinkler Wrench Sprinkler IdentiÞ cation Number (SIN): R5734 10. Standard Temperature Ratings ClassiÞ cation Sprinkler Temperature Rating Max. Ambient Temp. Bulb Color Ordinary Ordinary Intermediate (1) Intermediate High (1) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 100°F (38°C) 100°F (38°C) 150°F (66°C) 150°F (66°C) 225°F (107°C) Orange Red Yellow Green Blue (1) Listed and CertiÞ ed only by cULus. Vail Fire & Emergency Services 11/01/16 11. Technical Data: Orifice Size: ½” (15mm) Thread Size: 1” NPT per ANSI B2.1 Working Pressure: 175 psi (12 bar) Nominal K Factor - US / (Metric): 5.6 / (80) Product Description Reliable Model F3QR Dry Sprinklers are quick response sprinklers utilizing a durable 3mm frangible glass bulb. This quick response enables these sprinklers to apply water to a fire much sooner than standard response sprinklers of the similar temperature rating. Model F3QR Dry Sprinklers are intended for use in dry and preaction systems and in areas subjected to freezing tem- peratures, such as freezers and unheated portions inside and outside buildings. Environments wherein dry sprinklers are employed can be corrosive. For this reason, Model F3 Sprinklers have a special wax fillet placed in the gap between the cup that supports the bulb and the wrenching boss. This wax will not interfere with the operation of the sprinkler, and it prevents contaminents from entering the internal portion of the drop nipple. The wax must not be removed. Operation The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manu- factured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. When the tem- perature increases sufficiently, due to a fire, the bulb shatters allowing operating parts to clear the waterway. This enables the inlet seal to release air or water and subsequently, cause water flow over the deflector in a uniform spray pattern, con- trolling or extinguishing the fire. Ordering Information Specify: 1. Sprinkler Type (select one): (a) Model F3QR Dry Pendent (b) Model F3QR Dry Pendent/HB (c) Model F3QR Dry Recessed FP Pendent (d) Model F3QR Dry Recessed F1 Pendent (e) Model F3QR Dry Concealed Pendent (f) Model F3QR Dry Horizontal Sidewall (g) Model F3QR Dry Horizontal Sidewall/HB (h) Model F3QR Dry Recessed FP Horizontal Sidewall - UL (i) Model F3QR Dry Recessed F1 Horizontal Sidewall - UL & FM 2. Sprinkler Temperature Rating. 3. Sprinkler Finish. 4. Escutcheon type (F1 or FP). 5. Cover Plate/Escutcheon Finish. 6. Length: “A” Dimension (face of tee to face of ceiling or wall) in ¼” (6mm) increments. 7. Model F3QR Dry Pendent (a) is available without sprinkler can and escutcheon. Note: 1. The “A” dimension is based on a nominally gauged pipe thread “make-up” of 0.600” (15mm) per ANSI B2.1 [7½ threads approximately]. 2. All platings and paintings are decorative and intend- ed for interior use. General Installation Instructions Model F3QR dry sprinklers must be installed only in stan- dard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) pipe tees in the horizontal position, even at branch line ends. They should not be installed into elbows or pipe couplings located on drop nipples to the sprinklers. For these and other fittings including CPVC, the dry sprinkler should be installed into a fitting to allow protrusion into the fitting in accordance with the diagrams. The “A” dimension of the dry sprinkler, which extends into the freezers or a freezing zone from wet pipe systems, should be selected to provide, as a minimum, the specified lengths in inches shown in Fig. 10. Caution: Do not install Model F3QR Dry sprinklers into CPVC adapt- er fittings or tees that have an internal obstruction. This will damage the sprinkler and /or the fitting. Refer to Fig. 11. During installation, the following steps must be followed: 1. Cut the specified size hole (see illustrations) for the sprin- kler in the ceiling or wall directly in line with the tee. 2. Apply pipe joint compound to the 1” (25mm) pipe threads and install sprinkler using the Model F3 or XLO2 Sprinkler Wrench as specified1. 3. Install the Model FP push-on / thread-off escutcheon or CCP cover plate if required. Note: Installation of the Model F3QR Sprinklers is not recom- mended in copper pipe systems, as this may reduce the life expectancy of the sprinklers. Model F3QR Concealed and Recessed In- stallation Instructions • The Model XLO2 wrench (Fig. 12) is designed to lo- cate on the wrenching pads of the recessed sprin- kler while centering in the cup1. A standard ½” drive ratchet may be used to drive this wrench. Fig. 13 and Fig. 14 show sequentially the insertion of the wrench. First the wrench, with its jaws above the sprinkler de- flector, is moved laterally until centered with the cup. Then raise the wrench inside of the cup until its jaws engage the sprinkler’s square wrenching pads (Fig. 14). To remove the wrench, follow this procedure in reverse order. Care should be taken to avoid striking the deflector, with the wrench. • Model F3 Wrench (Fig. 15) is used for installation of Pendent and Horizontal Sidewall sprinklers1. 1 Installation Wrenches: Throughout this technical bulletin, Reliable has specified specific installation wrenches for use on each version of our sprinklers. A pipe wrench may also be used to install a dry sprinkler provided that it only interfaces with the steel outer tube of the assembly (Item #8 on fig 16). Keep in mind that a pipe wrench will incorporate a large amount of torque into the final assembly. This torque will have to be matched or exceeded upon the sprinkler’s removal at a later date. Vail Fire & Emergency Services 11/01/16 12. Fig. 10 Vail Fire & Emergency Services 11/01/16 13. Fig. 11 Vail Fire & Emergency Services 11/01/16 14. Fig. 13 - XLO2 Wrench Fig. 15 - F3 Wrench Fig. 14 - XLO2 Wrench Fig. 12 - XLO2 Wrench • Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SER- VICE FOR FIRE PROTECTION. Removal of the pro- tectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PRO- TECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Maintenance The Model F3QR Quick Response Dry Sprinklers should be inspected and the sprinkler system maintained in accor- dance with NFPA 25. Do not remove the factory applied thermally sensitive wax fillet between the bulb supporting cup and the wrenching boss. Do not replace this wax with a substitute substance. An Alternate substance may interfere with proper operation of the sprinkler. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gently vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non- operation. Vail Fire & Emergency Services 11/01/16 15. ITEM # DESCRIPTION MATERIAL SPECIFICATION 1 FRAME BRASS PER UNS C83600 2 DEFLECTOR BRONZE PER UNS C51000 3 LOAD SCREW BRASS PER UNS C22000 4 SEAT ADAPTOR BRASS ALLOY PER UNS C36000 5 BULB INSERT COPPER ALLOY PER UNS C331400 6 GLASS BULB GLASS W/GLYCERIN SOLUTION 7 ORIFICE ADAPTOR BRASS ALLOY PER UNS C36000 8 OUTER TUBE GALVANIZED STEEL 9 INNER TUBE BRASS ALLOY PER UNS C23000 10 YOKE BRASS ALLOY PER UNS C38000 11 INLET BRASS ALLOY PER UNS C35330 12 CAP BRASS ALLOY PER UNS C54400 13 SPRING WASHER/SEAL TEFLON COATED BERYLLIUM NICKEL 14 FLIP DISK BRASS ALLOY PER UNS C54400 15 CAN/ESCUTCHEON PAINTED OR PLATED MILD STEEL Fig. 16 MATERIAL SPECIFICATIONS Vail Fire & Emergency Services 11/01/16 Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 02/15 P/N 9999970175 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Reliable...For Complete Protection Vail Fire & Emergency Services 11/01/16 Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Open Sprinklers Bulletin 104 Rev. Q Bulletin 104 Rev. Q Reliable Models G & F1 Open Sprinklers are similar in design to Reliable Models G & F1 Automatic Sprinklers except they are not equipped with fusible or frangible ele- ment parts, and therefore, do not operate automatically. They are installed in locations where a blanket of water is desired over a predetermined area. Open Sprinkler systems can be operated manually or by quick opening valves that are pneumatically, hydraulically or electrically controlled. Open Sprinklers are available in four types: Standard Upright, Standard Pendent, Conventional. and Sidewall. All Open Sprinklers are available in the following finishes: Plain Bronze, lead plated wax coated or wax coated over lead plated, Electroless Nickel PTFE plated. No waterway protection is provided. Consult factory for other finishes. The following table lists Reliable Open Sprinklers by type, orifice size, pipe connection size, overall length, in- stallation position and SIN. Installation positions other than the design installation position shown in the table may be used. However, the resulting distribution pattern in the installed position must be carefully considered. Type OriÞ ce Size NPT Thread K Factor Overall Length Installation Position Sprinkler IdentiÞ cation Number (SIN) US Metric Standard Upright (Model G) 5/16”, 3/8”, 7/16” 1/2” 17/32” 1/2” 1/2” 1/2”, 3/4” 1.98, 2.82, 4.24 5.62 7.96, 8.20 30, 40, 60, 80, 115 27/8” 27/8” 27/8”, 215/16” Upright Upright Upright R1022, R1021, R1023 R1025, R1026, R1027 Standard Pendent (Model G) 5/16”, 3/8”, 7/16” 1/2” 17/32” 1/2” 1/2” 1/2”, 3/4” 1.98, 2.82, 4.24 5.62 7.96, 8.20 30, 40, 60, 80, 115 27/8” 27/8” 27/8”, 215/16” Pendent Pendent Pendent R1012, R1011, R1013 R1015, R1016, R1017 Conventional (Model G) 1/2” 17/32” 1/2” 3/4” 5.62 8.20 80, 115 27/8” 215/16” Upright or Pendent Upright or Pendent R1075, R1077 Sidewall (Model G) 1/2” 1/2” 1/2” 1/2” 5.62 5.62 80, 80 27/8” 35/16” Upright or Pendent Horizontal R1285, R1235 Standard Upright (Model F1) 3/8”, 7/16” 1/2” 17/32” 1/2” 1/2” 3/4” 2.82, 4.24 5.62 8.00 40, 60 80, 115 2.20” 2.20”, 2.25” 2.31” Upright Upright Upright R1721, R1723 R1725, RA1325 R1722** Standard Pendent (Model F1) 3/8”, 7/16” 1/2” 17/32” 1/2” 1/2” 3/4” 2.82, 4.24 5.62 8.00 40, 60, 80, 115 2.20” 2.20”, 2.25” 2.31” Pendent Pendent Pendent R1711, R1713 R1715, RA1314 R1712** Conventional (Model F1) 1/2” 17/32” 1/2” 3/4” 5.62 8.00 80, 115 2.20”, 2.25” 2.30” Upright or Pendent Upright or Pendent R1775, RA1375 R1772 Sidewall (Model F1) 1/2” 1/2” 1/2” 1/2” 5.62 5.62 80, 80 2.20”, 2.25” 2.63” Upright or Pendent Horizontal R1785, RA1385 R1735, RA1335 Extended Coverage (Model GFR VELO-ECOH) 11/16” 3/4” 14.00 200 27/8” Pendent R6043**, R6553** Refer to the appropriate automatic sprinkler product bulletins for listing and approval information. **SIN R1712, R1722, R6043 and R6553 are UL listed for Electroless Nickel PTFE plating of the waterway. Vail Fire & Emergency Services 11/01/16 Model F1 Standard Upright Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 09/15 P/N 9999970003 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Model G & F1 - Open Standard (Spray) Upright and Pendent Sprinklers Models G and F1 standard upright and pendent sprin- klers distribute water laterally and downward in a wide pattern approximating a half sphere. This hemisphere is completely and uniformly filled with water in the form of small drops and spray. A circular area, from 12 to about 20 ft. (3.7 to 6.1m) in diameter, is covered 10 ft. (3.0m) below the sprinkler at minimum water discharge pres- sure. See Technical Bulletins 110, 117 and 013. Model G & F1 - Conventional Open Style Sprinkler This deflector configuration is used primarily in those countries where the LPC installation rules have prece- dence. The sprinkler distributes approximately 60% of its water discharge upward against the ceiling with the bal- ance downward. It may be installed in either the upright or pendent position. Sprinklers with conventional deflec- tors are available with orifice sizes corresponding to light, ordinary and extra–hazard installations. See Technical Bulletins 110, 117 and 013. Model G & F1 - Open Sidewall Sprinklers This deflector configuration is designed for use where standard sprinklers are deemed impartial because of decorative or structural conditions. It discharges approx- imately 15% of the water on the wall behind it with the remaining 85% discharged in front of the sprinkler. The Model G & F1 Vertical Sidewall Sprinklers may be installed in either the upright or the pendent position, and are intended for light hazard occupancy use. The Model G & F1 Horizontal Sidewall Sprinklers are in- tended for light hazard occupancies and in some appli- cations may be used in ordinary hazard occupancies. See Technical Bulletins 112, 117 and 013. Model F1 Standard Pendent Model G Standard Pendent Model G Standard Upright Model G Standard Conventional Model F1/F156 Standard Conventional Model G Vertical Sidewall Model G Horizontal Sidewall Model F156 Horizontal Sidewall For specific water distribution information, refer to the spray distribution section of the catalog. Vail Fire & Emergency Services 11/01/16 Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Models F1 Series Standard Response Standard Spray Bulletin 013 Rev. L Bulletin 013 Rev. L Model F156 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model F156 Recessed Sprinkler Types Pendent/F1/F2/FP Horizontal Sidewall Model F142, F1XLH & F128 Sprinkler Types Standard Upright Standard Pendent Model F142, F1XLH & F128 Recessed Sprinkler Types Pendent/F1/F2/FP Approval Organizations 1. Underwriters Laboratories Inc. and certified for Canada (cULus) 2. Factory Mutual Approvals (FM) 3. Loss Prevention Council (LPCB, UK) 4. VdS Schadenverhütung GmbH 5. EC Certificate: 0786-CPD-40237 (RA1314) 0786-CPD-40253 (RA1325) 0786-CPD-40254 (RA1375) Recessed Pendent/F1/F2 Horizontal Sidewall Pendent Conventional Upright Vertical Sidewall Recessed Horizontal Sidewall Recessed Pendent/FP XLH Upright XLH Pendent XLH Recessed Pendent F1/F2 XLH Recessed Pendent FP UL Listing Category Sprinklers, Automatic & Open (VNIV) Product Description The F156, F142, F1XLH & F128 Series Glass Bulb Sprinkler combines the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. Whether installed on exposed piping or in an office ceil- ing, it is functional and attractive. Beautifully versatile is the description for the Reliable Models F156, F142, F1XLH & F128 Series Recessed glass bulb sprinkler. Recessing the F156, F142, F1XLH & F128 Series enhances its already low profile decorative appearance, and facilitates a rapid and perfect installa- tion. The recessed escutcheon of the Models F156, F142, F1XLH & F128 are highly adjustable. The two piece con- struction makes field installation a very easy and rapid task. This also allows ceiling panels to later be removed without shutting down the fire protection system, thus fa- cilitating maintenance of above ceiling services. The F156, F142, F1XLH & F128 Series Automatic Sprin- kler utilizes a 5.0 mm frangible glass bulb. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid phase and in the vapor phase. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distribute the discharging water. The F156, F142, F1XLH & F128 Series Sprinkler tem- perature rating is identified by the color of the glass bulb capsule as well as frame color where applicable. FOR HYDRAULIC PURPOSES OF OPEN DELUGE SPRINKLERS ONLY Vail Fire & Emergency Services 11/01/16 Technical data: Models Discharge CoefÞ cient Response Thread Size Max. Working Pressure Min. Working Pressure Temperature Rating Finish F156 K 5.6 Standard 1/2” NPT (R1/2) 175 PSI 7 PSI See “Temperature Ratings” Table See “Finish Table” F142 F1XLH K 4.2 F128 K 2.8 Material Data: Frame Deß ector Load Screw Pintle Cup Washer Bulb DZR Brass QM Brass CDA Alloy 260, CDA Alloy 220 or CDA Alloy 510 CDA Alloy 360 or CDA Alloy 544 CDA Alloy 360 or CDA Alloy 544 CDA Alloy 651 or CDA Alloy 693 Nickel Alloy 440 or Alloy 360 coated with PTFE Adhesive Tape Glass 2. Model F142, F1XLH Upright Vail Fire & Emergency Services 11/01/16 3. Model F156, Upright, Pendent & Conventional Sprinklers Model F142, F1XLH & F128 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal OriÞ ce Thread Size Nominal K Factor Sprinkler Height Approval Organization Sprinkler IdentiÞ cation Number (SIN) US Metric Upright Pendent Standard-Upright (SSU) and pendent Deß ectors Marked to Indicate Position 1/2” (15mm) (1) 1/2” NPT (R1/2) 5.6 80 2.25” (57mm) 1, 2, 3, 4, 5 RA1325(2)(3)(5)(6) RA1314(2)(3)(5)(6) 7/16” (10mm) 1/2” NPT (R1/2) 4.2 60 2.25” (57mm) 1 RA1323(2)(6) RA1313(6) 3/8 (10mm) 1/2” NPT (R1/2) 2.8 40 2.25” (57mm) 1 RA1321(2)(6) RA1311(6) Conventional-Install in Upright or Pendent Position 15mm (1) 1/2” NPT (R1/2) 5.6 80 57mm 3, 4, 5 RA1375(5) (1) Refer to Bulletin 024 for Special Response Sprinklers (F1S5-56) (2) cULus Listed corrosion resistant (Polyester coated) sprinkler. (3) Polyester coated FM Approved sprinkler. (4) ----- (5) Polyester coated LPCB & VdS approved sprinkler RA1325, RA1314 & RA1375. (6) Electroless Nickel PTFE (Teflon®)* Plated - UL listed Corrosion Resistant Pendent Conventional Upright Model F156, F142, F1XLH & F128 F1 or F2 Model F156, F142, F1XLH & F128 FP Model F156, F142, F1XLH & F128 Recessed Pendent Sprinklers(1) Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal OriÞ ce Thread Size K Factor Sprinkler Height Sprinkler IdentiÞ cation Number (SIN) US Metric 1/2” (15mm) 1/2” NPT (R1/2) 5.6 80 2.25” (57mm) RA1314(2) 7/16” (10mm) 1/2” NPT (R1/2) 4.2 60 2.25” (57mm) RA1313(2) 3/8” (10mm) 1/2” NPT (R1/2) 2.8 40 2.25” (57mm) RA1311(2) (1) Refer to escutcheon data table for approvals & dimensions (2) Electroless Nickel PTFE (Teflon®)* Plated - cULus listed Corrosion Resistant *DuPont Registered Trademark Vail Fire & Emergency Services 11/01/16 4. Model F156 Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy U.S. Patent No. 6,374,920 Sprinkler Type Deß ector to Ceiling Distance (Min. - Max.) Upright 4” (102mm) - 12” (305mm) Pendent 4” (102mm) - 12” (305mm) Installation Data: Nominal OriÞ ce Thread Size Nominal K Factor Sprinkler Height Approval (1) Organizations Sprinkler IdentiÞ cation Numbers (SIN) US Metric ½” (15mm) ½” NPT (R1/2) 5.6 8.0 2.25” (57mm) 1, 2, 3 RA1385(1)(2)(3)(4) (1) LPC Approval is pendent only, 57°C through 141°C ratings. (2) cULus Listed corrosion resistant (Polyester coated) sprinkler. (3) cULus Listed & FM Approved corrosion resistant for lead, wax and wax over lead. (4) Electroless Nickel PTFE (Teflon®)* Plated - cULus listed Corrosion Resistant Model F156 Horizontal Sidewall Sprinkler Deß ector: HSW Installation Wrench: Model D Sprinkler Wrench Installation Data:Horizontal Sidewall Nominal OriÞ ce Thread Size Nominal K Factor Sprinkler Height Approval Organizations Sprinkler IdentiÞ cation Numbers (SIN) US Metric Light Hazard Ordinary Hazard ½” (15mm) ½” NPT (R1/2) 5.6 80 2.63” (67mm) 1, 2 1 RA1335(1)(2)(3)(4) (1) cULus Listed corrosion resistant (Polyester coated) sprinkler. (2) cULus Listed & FM Approved corrosion resistant for lead, wax and wax over lead. (3) Polyester coated FM approved sprinkler. (4) Electroless Nickel PTFE (Teflon®)* Plated - cULus listed Corrosion Resistant Horizontal Sidewall Vertical Sidewall Note: For Recessed HSW Sprinklers use installation wrench GFR2. FM and cULus permits use with F1 or F2 escutcheons for “Light Hazard” only. *DuPont Registered Trademark Vail Fire & Emergency Services 11/01/16 Application Model F156, F142, F1XLH, F128 & Model F156, F142, F1XLH & F128 Recessed sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must exercised that the orifice size, temperature rating, deflector style and sprinkler type are in ac- cordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Jurisdic- tion Installation. Installation Model F156, F142, F1XLH & F128 Series sprinklers are standard response sprinklers intended for installation as specified in NFPA 13. They must also be installed with the Model D Sprinkler Wrench specifically designed by Reliable for use with these sprinklers. The Model F156, F142, F1XLH & F128 Recessed Sprinklers are to be installed with a maximum recess of ¾ inch (19mm). The Model F1, F2, and FP Escutcheon illustrated are the only recessed escutcheon to be used with the Model F156, F142, F1XLH & F128 Recessed Sprinklers. The use of any other recessed escutcheon will void all approvals and negate all warranties. When installing Model F156, F142, F1XLH & F128 Recessed Sprinklers use the Model GFR2 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. Note: A leak tight ½” NPT (R1/2) sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. Glass bulb sprinklers have orange covers to protect the bulb dur- ing the installation process. REMOVE THIS PROTECTION ONLY AFTER THE SYSTEM HAS BEEN HYDROSTATICALLY TESTED AND, WHEN APPLICABLE, THE ESCUTCHEONS HAVE BEEN INSTALLED. RASCO wrenches are designed to install sprinklers when covers are in place. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Orifice Size 4. Deflector Type 5. Temperature Rating: - Specify when ordering - Model F156 Pendent Sprinkler 6. Sprinkler Finish 7. Escutcheon Finish (where applicable) Note: When Models F156, F142, F1XLH & F128 Recessed Sprinklers are ordered, the sprinklers and escutcheons are packaged separately. Escutcheon Data (1) (1) SIN: RA1335 - cULus and FM permits use with F1 or F2 escutcheons for light hazard only. Maintenance The Model F156, F142, F1XLH & Model F156, F142, F1X- LH & F128 Recessed Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluid. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause im- proper operation or non-operation. Temperature Ratings ClassiÞ cation Sprinkler Temperature Max. Ambient Temp. Bulb Color °C °F Ordinary Ordinary Intermediate Intermediate High(1) Extra High(1) Ultra High (1) (2) 57 68 79 93 141 182 260 135 155 175 200 286 360 500 100°F (38°C) 100°F (38°C) 150°F (66°C) 150°F (66°C) 225°F (107°C) 300°F (149°C) 475°F (246°C) Orange Red Yellow Green Blue Mauve Black (1) Not available for recessed Sprinklers. (2) cULus listed for SIN RA1325 and RA1314 only. Maximum Working Pressure 175 psi (12 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) Finish(1) Standard Finishes Sprinkler Escutcheon Bronze Chrome Polyester Coated (6)(7)(9) Brass Chrome White Painted Special Application Finishes Sprinkler Escutcheon Electroless Nickel PTFE(Teflon®)*(3)(10) Bright Brass(2) Black Plated Black Paint(3)(9) Off White(3)(9) Chrome Dull Lead Plated(3)(4)(8) Wax Coated(3)(4)(5)(8) Wax Over Lead(3)(4)(5)(8) Electroless Nickel PTFE (Teflon®)* Bright Brass Black Plated Black Paint Off White Chrome Dull (1) Other colors and finishes are available on special order. Consult factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. (2) 200°F (93°C) maximum. (3) UL and ULC listed only. (4) 155°F to 200°F (68°C to 93°C) ratings only. (5) 286°F (141°C) sprinklers may be coated for ambient conditions not exceeding 150°F (66°C). (6) cULus listed “corrosion resistant” applies to SIN Number RA1325 (Upright) RA1323 (upright), RA1321(Upright), RA1335 (HSW), RA1385(VSW) and RA1314 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. (7) FM Approved finish as “Polyester Coated” applies to SIN number RA1314, RA1335 & RA1325 in standard black or white. (8) FM Approved finish applies only to SIN number RA1335 & RA1385. (9) LPCB and VdS Approved finish applies only to RA1325, RA1314 and RA1375. (10) cULus listed Corrosion Resistant applies to SIN RA1325 ,RA1314 ,RA1323, RA1313 ,RA1321, RA1311, RA1385 and RA1335 5. *DuPont Registered Trademark Vail Fire & Emergency Services 11/01/16 • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Reliable...For Complete Protection Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 04/15 P/N 9999970299 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Vail Fire & Emergency Services 11/01/16 The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Bulletin 180 Rev. C Bulletin 180 Rev. C Pilot Line Detector (PLD) Fixed Temperature Release F1-FTR Fixed Temperature Release Features: 1. Fixed Temperature Heat Responsive Detector 2. Installed Positions: • Pendent • Upright 3. Quick Response 4. Temperature Ratings: 135°F (57°C), 155°F (68°C), 175°F (79°C), and 200°F (93°C). 5. ½” (15 mm) Orifice with ½” NPT (R½) Thread 6. Die cast Brass Frame 7. Listed spacing a. 40 ft x 40 ft (12 m x 12 m) for 155°F (68°C), 175°F (79°C) and 200°F (93°C) b. 50 ft x 50 ft (15 m x 15 m) for 135°F (57°C) Product Description: The Fixed Temperature Release (FTR) Pilot Line Detec- tor (PLD) is designed to be used on wet or dry pilot line release systems and trigger the operation of deluge sys- tems, non-interlock preaction systems, single interlock and double interlock systems. The FTR incorporates a 2.5 mm glass bulb with a Model F1 Sprinkler frame. It is identified as a Fixed Temperature Release (FTR) to differentiate it from a sprinkler. The FTR is made of die cast brass and is available in various finishes. During fire conditions the heat sensitive liquid in the bulb expands, the bulb shatters, releasing the cap and spring assem- bly. This triggers the opening of the pilot line, releasing the pressure (air, gas or water), causing the deluge or preaction system valve to open and deliver water under pressure to the system pipes. Listings and Approvals 1. Listed with Underwriters Laboratories Inc. and UL Certified for Canada (cULus) 2. NYC MEA 258-93-E Technical Data Thread Size: ½” NPT (R ½) Orifice: Nominal ½” (15 mm) Thermal Sensor: 2.5 mm glass bulb Rated to 175 psi (12,1 bar) (12,066 kPa) Frame – Die cast Brass Seal – Teflon Coated Standard Finishes – Brass, Chrome plated or Polyester White(1). Factory tested Hydrostatically to 500 psi (34,5 bar) (34,475 kPa). (1) Polyester White is UL and ULC Listed corrosion resistant. Installation The F1-FTR must be installed in accordance with NFPA- 13 specifications and after the pilot line system piping is in place (to prevent possible damage to FTR). Before install- ing be sure the F1-FTR has the appropriate temperature rating which should be lower than the temperature rating of system nozzles or sprinklers. Apply a small amount of pipe joint compound to the male thread when installing FTR. Install the F1-FTR into the pilot line piping using only the special Model D Wrench. (See Bulletin 205). The F1-FTR must be handled carefully, and stored in a cool, dry place in the original container. Never install a F1-FTR that has been dropped or damaged in anyway. Do not install the F1-FTR if the bulb is cracked or seems low on liquid. If the F1-FTR is not returned to Reliable it should be destroyed. Never install a F1-FTR that has been ex- posed to a temperature in excess of the allowed ambient temperature. The F1-FTR can be installed in any position; however, in locations where the pilot line system is exposed to freez- ing conditions install them in the upright position only. Wet pilot lines must be installed where there is adequate heat to avoid possible freezing. An F1-FTR pilot line that may be subject to mechanical damage must be protected by the appropriate sprinkler guard (see Bulletin 208) for the F1 Model. Vail Fire & Emergency Services 11/01/16 The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 02/12 P/N 9999970218 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Any alternation to the detectors after they leave the fac- tory including, but not limited to, painting, plating coating or other modification may render the detectors inopera- tive and will nullify all approvals. 6. Use guards on all detectors subject to injury by moving objects. 7. If pipe compound is used, apply to detector pipe thread only. 8. Store detectors in a cool, dry place. Prior to installation, detectors should be maintained in original cartons and packaging until used to minimize potential damage that would cause improper opera- tions or non-operation. 9. NEVER APPLY PAINT OR ANY OTHER COATING TO DETECTOR. 10. Removal of paint or other coatings with solvents is not permissible. 11. When installing detector in plastic pipe, excess solvent cement used during pipe installation must not become an obstruction in- side inlet. Install detector into the sprinkler fittings only after all piping is in place and solvent cement at each drop joint has cured at least 30 minutes. 1. Detectors are to be installed in accordance with the latest published standards of the National Fire Protection Association, other similar organizations and with the provisions of governmental codes or or- dinances whenever applicable. 2. Use only the Model D wrench to install detector. Any other wrench may damage the detector. 3. Never install a detector after it has been dropped or damaged in any way. These detectors should be destroyed. 4. Never Install detectors in the fittings until the piping is in place on the ceiling. Detectors are liable to be damaged if installed when the lines are made up at the bench or on the floor. 5. Never attach wiring, ropes or fixtures to a detector or piping system. After installation the entire pilot line system must be pressure-tested to ensure proper operation, meeting the required application standards, verifying that no unit was damaged in shipping on installation, and that all detectors are securely tightened. If a thread leak is noticed the unit must be removed, new pipe joint compound applied and then reinstalled. Maintenance Fire protection systems should be inspected in accor- dance with NFPA 25 guidance. Keeping the fire protection system in properly, maintained conditions is the respon- sibility of the owner. Model F1-FTR must be inspected regularly for corrosion, mechanical damage, paint etc. Do not clean them with soap and water, ammonia or any other cleaning fluid. Remove dust by using a soft brush or gentle vacuuming. Remove any detectors that have been painted (other than factory applied) or damaged in any way. A stock of spare detectors should be maintained to allow quick replacement of damaged or inoperable units. Prior to installation, all detectors should be maintained in the original cartons until used. This minimizes the potential for improper or non-operation. Systems subjected to fire must be returned to service as soon as possible. The en- tire system must be inspected for damage and repaired or replaced as necessary. Sprinklers and fixed temperature releases that have been exposed to corrosive products of combustion or high ambient temperatures, but have not been operated, should be replaced. Refer to the Author- ity Having Jurisdiction for minimum replacement require- ments. Release Temperature ClassiÞ cation Nominal Temperature Rating of Release (Fusing Point) Ceiling Temperature at Release Bulb Color Temperature Rating Color Code Listed Spacing(2) Max. Recommended Ambient Temp.(1) Ordinary 135°F (57°C) 100°F (38°C) Orange None 50 ft x 50 ft (15 m x 15 m) Ordinary 155°F (68°C) 100°F (38°C) Red None 40 ft x 40 ft (12 m x 12 m) Intermediate 175°F (79°C) 150°F (65°C) Yellow White 40 ft x 40 ft (12 m x 12 m) Intermediate 200°F (93°C) 150°F (65°C) Green White 40 ft x 40 ft (12 m x 12 m) (1) Based on NFPA-13. Other limits may apply depending on fire loading, sprinkler location, and other Authority-Having-Jurisdiction requirements. Refer to specific installation standards. (2) Listed spacings are for smooth, flat, horizontal ceilings. Installation must comply with NFPA 13; NFPA 15, 3-5.2 & NFPA 72, 2-2 and Appendix B Continued from page 1. Important Precautions To Follow Vail Fire & Emergency Services 11/01/16 May 28, 2015 Mr. Tom Frye, Principal Pierce + Frye Architects 30 West Benchmark Road, #217 Avon, CO 81620 970.949.0899 tfrye@piercefrye.com RE: GORSUCH RESTAURANT ADDITION, 232 BRIDGE STREET, VAIL CO 81657 Dear Mr. Frye, Rondinelli Life Safety (RLS) has evaluated the above mentioned building in order to develop equivalencies for the areas and aspects of the building’s construction that do not meet the prescriptive IBC Code requirements. Shown below are our comments pertaining to the Fire Protection and Life Safety Features of this building relative to IBC compliance. Documents, Drawings, Codes and Standards Used For This Evaluation (References)  The 2012 International Fire Code  The 2012 International Building Code  The Architectural Plan Set of the building done by Pierce + Frye Architects dated 2/14/2014  The Architectural Plan Set for the Restaurant Addition done by SempleBrown Design dated 2/4/2015  RLS’s building walkthrough of 5/18/2015 with the Project Architect Summary of the Building Evaluation The below information is based on the above shown References. 1) This is a non-separated mixed use building with occupancy types of A-2, B and M. 2) The building is approximately 50% fire sprinklered. Based on previous agreements with the Vail Fire and Building Departments, the building will be 100% fire sprinklered within a (3) year period. See the attached area distribution for the current fire sprinklered areas. 3) The building’s construction type is classified as a Type 5-A with non-separated use and as such, Section 508.3 (IBC) applies. Based on this IBC Section, the A-2 Occupancy governs the allowable area per story, height and number of stories. 4) The IBC allowable area per story for an A-2 Occupancy is 11,500 square feet. The maximum existing area on any one story is 7,812 square feet so all floors are within the allowable area per story. 5) The IBC maximum number of allowable stories for an A-2 Occupancy is (2). An additional story would be allowed after the building is fully fire sprinklered. 6) This building has been classified as a (5) story however levels three, four and five are each only 350 square feet and used as offices only with no storage. As a B Occupancies, these levels are not required by the IFC to be fire sprinklered however are 100% fire sprinklered. Vail Fire & Emergency Services 11/01/16 7) The IBC maximum allowable height for a Type 5-A Building is 50 feet. This building is 63 feet in height however the top 17 feet is an architectural feature only and not part of the building’s occupiable space. In addition, after the building is 100% fire sprinklered a height increase of 20% of the maximum allowable height can be added bringing the total allowable height to 60 feet. 8) A smoke detection system is installed throughout the building. 9) Egress looked to be in compliance with (IBC) Chapter 10. Proposed Restaurant Addition A 505 square foot (net) addition has been proposed on the west side of this building which will increase the size of the restaurant at Street level to 1,457 square feet. As shown in the Architectural Plan Sets, the wall on the west side of the building is planned to be built using hollow structural steel as the framework for operable glass doors. The concept for this addition is for the doors to be open as weather permits. Rondinelli Life Safety offers the comments below as consideration for the issuance of a permit for this addition. 1) With this restaurant addition, the allowable area per floor is not exceeded per the IBC. 2) The restaurant is not required to be fire sprinklered however will be. 3) IBC Section 705.8 allows unlimited unprotected openings in the first story above grade plane where the wall faces a street and has a fire separation distance of 15 feet. There is a fire separation distance of 12.5 feet in place. 4) IBC Table 705.8 limits the allowable area of openings in an exterior wall in a sprinklered building with a separation distance between 10 and 15 feet to 45%. 5) As a Type 5-A Building, exterior walls are required to be 1-hour fire-resistance rated. To compensate for line items 3), 4) and 5) above, Rondinelli Life Safety (RLS) proposes that a Dry Pilot Line Actuated Deluge System be installed along the length of the building’s west wall. The fire sprinklers for this system will be open (no release mechanism) and spaced between 6 feet and 8 feet on center. Each sprinkler will be designed to flow 3 gpm per lineal foot (NFPA 13 Section 11.3.3) so on a heat activated fire event, the west wall of this building becomes a water curtain. RLS believes that a deluge system, along with the completion of providing fire sprinklers throughout the building, will provide an equivalent level of fire protection to meet the IBC fire-resistance rating and opening protection requirements for the west exterior wall of this restaurant addition. Please contact me if there are any questions pertaining to the content of this letter. Sincerely, RONDINELLI LIFE SAFETY Charles D. Gallagher, P.E. Fire Protection Engineer Attachments: Sprinklered Area Distribution Schematic Diagram of a Deluge System Vail Fire & Emergency Services 11/01/16 Vail Fire & Emergency Services 11/01/16 Vail Fire & Emergency Services 11/01/16