Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
F17-0037_Material submittal sheet_1500502620.pdf
7026 South Tucson Way Centennial, CO 80112 (303) 792-0022 Fax (303) 792-9049 Fire Protection Hydraulic and Equipment Submittal Village Inn Plaza Building 100 – Unit 107 68 E Meadow Dr. Vail, CO 81657 Prepared by: Joshua Adam Project Manager Western States Fire Protection Co. 7026 South Tucson Way Centennial. CO 80112 (720) 895-5216 Email: josh.adam@wsfp.us Hydraulic Summary Report Description: Residential Job Number: 1 Node Flow(gpm) Total Hose Streams 100.00 Safety MarginRequiredAvailable Node Hose Flow Static Residual Flow Total Demand (gpm)(psi)(psi)(gpm)(psi)(gpm)(psi)(psi)@@Name 10 140.035 65.802 74.233764.00100.00 40.000150.000 208.62Water Supply Design EngineerJob Number Total Water Required (Including Hose Allowance) 208.62 Maximum Pressure Unbalance In Loops 0.000 Additional Hose Supplies 100.00 Hose Allowance At Source Supplies 511.34gal Residential 0.100gpm/ft² 256.00ft² 523.00ft² (Actual 522.31ft²) 4 Occupancy Area of Application Coverage Per SprinklerNumber Of Sprinklers Calculated Density Job Suffix AutoPeak Results: Pressure For Remote Area(s) Adjacent To Most Remote Area Volume capacity of Dry PipesVolume capacity of Wet Pipes Maximum Velocity Under Ground 19.03 between nodes 9 and 8 Maximum Velocity Above Ground 5.8 K-Factor 25.60 at 19.482 Most Demanding Sprinkler Data System VAIL, CO Job Site/Building VILLIAGE PLAZA INN, 68 E MEADOW DR AHJ ROBINSON CONDO UNIT #107 Job State Certification/License NumberJob Name: 1 Contractor Contractor Number Name of Contractor: Address 1 Address 2 Contact Name Contact Title ExtensionPhone FAX E-mail Web-SiteAddress 3 Address 1 Address 2 Drawing Name robinson condo System Flow Demand 108.62 Remote Area(s) Address 3 7/13/2017© M.E.P.CAD, Inc.Page 1AutoSPRINK® 12 v12.0.59.0 10:05:36AM Hydraulic Graph Report Description: Residential Job Number: 1 40.000 @ 764.00 Residual: Pressure 150.000 Static: Pressure Water Supply at Node 10 Hydraulic Graph Water Supply at Node 10 65.802 @ 108.62 65.802 @ 208.62 Available Pressure at Time of Test 140.035 @ 208.62 System Demand System Demand (Including Hose Allowance at Source) © M.E.P.CAD, Inc.7/13/2017 Page 2AutoSPRINK® 12 v12.0.59.0 10:05:41AM Device (gpm) Actual Flow Minimum Flow (gpm)(K) K-Factor (psi) Pressure Summary Of Outflowing Devices Report Description: Residential Job Number: 1 Sprinkler 201 25.60 25.60 5.8 19.482 Sprinkler 202 25.64 25.60 5.8 19.542 Sprinkler 203 28.67 25.60 5.8 24.439 Sprinkler 204 28.71 25.60 5.8 24.498 Most Demanding Sprinkler Data © M.E.P.CAD, Inc.7/13/2017 Page 3AutoSPRINK® 12 v12.0.59.0 10:05:47AM Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: 1 Report Description: Residential • • • • • Route 1 • • • • • Pf Pe Pv DR 1.0550 25.60 9.40 0.132243 5'-7¾1.276 201 -1'-0 25.60 5.8 19.482 4'-0 -0.434 1 0'-0 20.324 9'-7¾ 150 Sprinkler, E(2'-0), T(2'-0) Pf Pe Pv BL 1.0550 51.24 18.81 0.477426 10'-11¾5.245 1 0'-0 25.64 20.324 8 0'-0 25.570 10'-11¾ 150 Flow (q) from Route 2 Pf Pe Pv BL 1.5270 108.62 19.03 0.316595 29'-5 11.847 8 0'-0 28.67 + 28.71 25.570 8'-0 9 0'-0 37.417 37'-5 150 Flow (q) from Route 3 and 4 E(2'-6), 2cplg(1'-0), C(3'-6), CV, BalV Pf Pe Pv BL 1.6100 108.62 17.12 0.369693 19'-9¼8.785 9 0'-0 37.417 4'-0 3 0'-0 46.202 23'-9¼ 120 E(4'-0) Pf Pe Pv BL 4.0260 108.62 2.74 0.004259 13'-3¾0.483 3 0'-0 46.202 100'-0 4 0'-0 46.684 113'-3¾ 120 6E(10'-0), 2T(20'-0) Pf Pe Pv FR 4.0260 108.62 2.74 0.004259 22'-6 0.125 4 0'-0 46.684 6'-9½9.754 5 -22'-6 56.563 29'-3½ 120 fE(6'-9½) Pf Pe Pv FM 4.0260 108.62 2.74 0.004259 90'-4¼11.041 5 -22'-6 56.563 154'-0 2.601 6 -28'-6 70.205 244'-4¼ 120 8E(10'-0), 2T(20'-0), 5fE(6'-9½), BFP(-10.000) Pf Pe Pv BL 6.0650 108.62 1.21 0.000579 9'-8½0.023 6 -28'-6 70.205 30'-0 1.301 7 -31'-6 71.529 39'-8½ 120 3fE(10'-0) Pf Pe Pv BL 6.2800 108.62 1.13 0.000367 161'-6 0.125 7 -31'-6 71.529 179'-7¾-5.853 10 -18'-0 65.802 341'-1¾ 140 6E(22'-0¾), T(47'-3¼), S 208.62 100.00 Hose Allowance At Source 10 • • • • • Route 2 • • • • • Pf Pe Pv DR 1.0550 25.64 9.41 0.132625 5'-2 1.215 202 -1'-0 25.64 5.8 19.542 4'-0 -0.434 1 0'-0 20.324 9'-2 150 Sprinkler, E(2'-0), T(2'-0) • • • • • Route 3 • • • • • Pf Pe Pv DR 1.0550 28.67 10.52 0.163097 5'-7 1.564 203 -1'-0 28.67 5.8 24.439 4'-0 -0.434 8 0'-0 25.570 9'-7 150 Sprinkler, E(2'-0), C(2'-0) • • • • • Route 4 • • • • • Pf Pe Pv DR 1.0550 28.71 10.54 0.163460 5'-2½1.506 204 -1'-0 28.71 5.8 24.498 4'-0 -0.434 8 0'-0 25.570 9'-2½ 150 Sprinkler, E(2'-0), C(2'-0) 1.51 4.87 )(150 1.33 140 1.16 130 0.713 100 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter = Factor C Value Multiplier Value Of C Multiplying Factor © M.E.P.CAD, Inc.7/13/2017 Page 4AutoSPRINK® 12 v12.0.59.0 10:05:54AM Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: 1 Report Description: Residential Pipe Type Legend AO Arm-Over BL Branch Line CM Cross Main DN Drain DR Drop DY Dynamic FM Feed Main FR Feed Riser MS Miscellaneous OR Outrigger RN Riser Nipple SP Sprig ST Stand Pipe UG Underground Units Legend Diameter Inch Elevation Foot Flow gpm Discharge gpm Velocity fps Pressure psi Length Foot Friction Loss psi/Foot HWC Hazen-Williams Constant Pt Total pressure at a point in a pipe Pn Normal pressure at a point in a pipe Pf Pressure loss due to friction between points Pe Pressure due to elevation difference between indicated points Pv Velocity pressure at a point in a pipe Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Ee1 11¼° Elbow Ee2 22½° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap © M.E.P.CAD, Inc.7/13/2017 Page 5AutoSPRINK® 12 v12.0.59.0 10:05:54AM Hydraulic Summary Report Description: Residential Job Number: 1 Node Flow(gpm) Total Hose Streams 100.00 Safety MarginRequiredAvailable Node Hose Flow Static Residual Flow Total Demand (gpm)(psi)(psi)(gpm)(psi)(gpm)(psi)(psi)@@Name 10 145.236 74.787 70.449764.00100.00 40.000150.000 140.00Water Supply Design EngineerJob Number Total Water Required (Including Hose Allowance) 140.00 Maximum Pressure Unbalance In Loops 0.000 Additional Hose Supplies 100.00 Hose Allowance At Source Supplies 511.34gal Residential 0.100gpm/ft² 400.00ft² 900.00ft² (Actual 173.26ft²) 1 Occupancy Area of Application Coverage Per SprinklerNumber Of Sprinklers Calculated Density Job Suffix AutoPeak Results: Pressure For Remote Area(s) Adjacent To Most Remote Area Volume capacity of Dry PipesVolume capacity of Wet Pipes Maximum Velocity Under Ground 14.68 between nodes 2 and 101 Maximum Velocity Above Ground 5.8 K-Factor 40.00 at 47.562 Most Demanding Sprinkler Data System VAIL, CO Job Site/Building VILLIAGE PLAZA INN, 68 E MEADOW DR AHJ ROBINSON CONDO UNIT #107 Job State Certification/License NumberJob Name: 1 Contractor Contractor Number Name of Contractor: Address 1 Address 2 Contact Name Contact Title ExtensionPhone FAX E-mail Web-SiteAddress 3 Address 1 Address 2 Drawing Name robinson condo System Flow Demand 40.00 Remote Area(s) Address 3 7/13/2017© M.E.P.CAD, Inc.Page 1AutoSPRINK® 12 v12.0.59.0 10:06:29AM Hydraulic Graph Report Description: Residential Job Number: 1 40.000 @ 764.00 Residual: Pressure 150.000 Static: Pressure Water Supply at Node 10 Hydraulic Graph Water Supply at Node 10 74.787 @ 40.00 74.787 @ 140.00 Available Pressure at Time of Test 145.236 @ 140.00 System Demand System Demand (Including Hose Allowance at Source) © M.E.P.CAD, Inc.7/13/2017 Page 2AutoSPRINK® 12 v12.0.59.0 10:06:34AM Device (gpm) Actual Flow Minimum Flow (gpm)(K) K-Factor (psi) Pressure Summary Of Outflowing Devices Report Description: Residential Job Number: 1 Sprinkler 101 40.00 40.00 5.8 47.562 Most Demanding Sprinkler Data © M.E.P.CAD, Inc.7/13/2017 Page 3AutoSPRINK® 12 v12.0.59.0 10:06:40AM Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: 1 Report Description: Residential • • • • • Route 1 • • • • • Pf Pe Pv BL 1.0550 40.00 14.68 0.301954 22'-4¼7.352 101 0'-0 40.00 5.8 47.562 2'-0 2 0'-0 54.915 24'-4¼ 150 Sprinkler, T(2'-0) Pf Pe Pv BL 1.5270 40.00 7.01 0.049875 7'-0½0.401 2 0'-0 54.915 1'-0 9 0'-0 55.316 8'-0½ 150 CV, BalV, cplg(1'-0) Pf Pe Pv BL 1.6100 40.00 6.30 0.058240 19'-9¼1.384 9 0'-0 55.316 4'-0 3 0'-0 56.700 23'-9¼ 120 E(4'-0) Pf Pe Pv BL 4.0260 40.00 1.01 0.000671 13'-3¾0.076 3 0'-0 56.700 100'-0 4 0'-0 56.776 113'-3¾ 120 6E(10'-0), 2T(20'-0) Pf Pe Pv FR 4.0260 40.00 1.01 0.000671 22'-6 0.020 4 0'-0 56.776 6'-9½9.754 5 -22'-6 66.550 29'-3½ 120 fE(6'-9½) Pf Pe Pv FM 4.0260 40.00 1.01 0.000671 90'-4¼10.164 5 -22'-6 66.550 154'-0 2.601 6 -28'-6 79.315 244'-4¼ 120 8E(10'-0), 2T(20'-0), 5fE(6'-9½), BFP(-10.000) Pf Pe Pv BL 6.0650 40.00 0.44 0.000091 9'-8½0.004 6 -28'-6 79.315 30'-0 1.301 7 -31'-6 80.620 39'-8½ 120 3fE(10'-0) Pf Pe Pv BL 6.2800 40.00 0.41 0.000058 161'-6 0.020 7 -31'-6 80.620 179'-7¾-5.853 10 -18'-0 74.787 341'-1¾ 140 6E(22'-0¾), T(47'-3¼), S 1.51 4.87 )(150 1.33 140 1.16 130 0.713 100 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter = Factor C Value Multiplier Value Of C Multiplying Factor © M.E.P.CAD, Inc.7/13/2017 Page 4AutoSPRINK® 12 v12.0.59.0 10:06:47AM Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: 1 Report Description: Residential Pipe Type Legend AO Arm-Over BL Branch Line CM Cross Main DN Drain DR Drop DY Dynamic FM Feed Main FR Feed Riser MS Miscellaneous OR Outrigger RN Riser Nipple SP Sprig ST Stand Pipe UG Underground Units Legend Diameter Inch Elevation Foot Flow gpm Discharge gpm Velocity fps Pressure psi Length Foot Friction Loss psi/Foot HWC Hazen-Williams Constant Pt Total pressure at a point in a pipe Pn Normal pressure at a point in a pipe Pf Pressure loss due to friction between points Pe Pressure due to elevation difference between indicated points Pv Velocity pressure at a point in a pipe Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Ee1 11¼° Elbow Ee2 22½° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap © M.E.P.CAD, Inc.7/13/2017 Page 5AutoSPRINK® 12 v12.0.59.0 10:06:47AM Model RFC Series Residential Sprinklers Flat Cover Plate, Concealed Pendent Sprinkler cULus Listed Bulletin 006 Rev. K February 2017 Product Features • cULus Listed as Residential Sprinklers • Push-On cover plate installation • Low water flow requirements Product Description Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in ac- cordance with UL 1626. Model RFC30, RFC43, and RFC49 sprinklers have a 165°F (74°C) temperature rated fusible-link operating element. Model RFC58 sprinklers are offered with either a 165°F (74°C) or 212°F (100°C) temperature rated fusible-link op- erating element. Sprinklers with a 165°F (74°C) temperature rating are ordinary temperature classification and should be used with a 135°F (57°C) temperature rated cover plate. Sprinklers with a 212°F (100°C) temperature rating are inter- mediate temperature classification and should be used with a 165°F (74°C) temperature rated cover plate. Model RFC Series sprinklers are installed with a Model RFC cover plate. Model RFC cover plates may be installed by either pushing or threading the cover plate into the sprinkler cup. Model RFC30, RFC43, and RFC49 sprinklers allow 1/2” (13 mm) of cover plate adjustment. Model RFC58 sprinklers allow 3/4” (19 mm) of cover plate adjustment. Model RFC cover plates are available in a variety of finishes as listed in Table H. In addition, Model RFC cover plates may be ordered as either traditional solid cover plates or perforated cover plates. Sprinkler Model Nominal K-Factor gpm/psi1/2 (l/min/bar1/2) Max. Coverage Area ft x ft (m x m) Sprinkler Identification Number (SIN) RFC30 3.0 (43.2)14 x 14 (4.3 x 4.3)RA0611 RFC43 4.3 (62)20 x 20 (6.1 x 6.1)RA0612 RFC49 4.9 (70.6)20 x 20 (6.1 x 6.1)RA0616 RFC58 5.8 (84)20 x 20 (6.1 x 6.1)RA0613 Table A www.reliablesprinkler.com Model RFC43Model RFC30 Model RFC49 Model RFC58 Model RFC Cover Plate Solid Perforated Model RFC58 Residential Sprinkler SIN RA0613 Technical Specifications Style: Flat Concealed Pendent Threads: 1/2” NPT or ISO 7-1 R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Chrome Plated Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Ratings Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model RFC Cover Plate Sprinkler Wrench Model FC Listings and Approvals cULus Listed Model RFC58 Sprinkler Components and Dimensions Figure 4 Model RFC58 Sprinkler Hydraulic Design Criteria Table E Minimum Flow and Residual Pressure Max. Coverage Area(2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) 16 x 16 (4.9 x 4.9) 16 (60.6) 7.6 (0.53) 18 x 18 (5.5 x 5.5) 18 (68.1) 9.6 (0.66) 20 x 20 (6.1 x 6.1) 20 (75.7) 11.9 (0.82) Bulletin 006 Rev. K February 2017 Page 5 of 7 www.reliablesprinkler.com Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table E above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bottom View Standard Finishes Special Application Finishes White Polyester Off White Paint Black Paint Raw Brass Chrome Plated Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Clad(3) Custom Color Paint(2) Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Custom color paint is semi-gloss, unless specified otherwise. 3. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the back side. Cover plates are not listed or approved as corrosion resistant. Stainless steel clad cover plates are not available perforated. Cover Plate Finishes(1) Table H Bulletin 006 Rev. KFebruary 2017 Page 6 of 7www.reliablesprinkler.com Sprinkler Model Cover Plate Model Cover Plate Diameter inch (mm) Recommended Hole Diameter in Ceiling inch (mm) Cover Plate Adjustment inch (mm) Min. to Max. Face of Fitting to Ceiling(1) inch (mm) Min. to Max. Dropped Deflector Distance below Ceiling inch (mm) Cover Plate Temperature Rating RFC30 RFC43 RFC49 RFC 3-5/16(84)2-5/8(67)1/2(13)1-1/2 to 2(38 to 51)1/2 to 1(13 to 25)135°F(57°C) RFC58 RFC 3-5/16 (84) 2-5/8 (67) 3/4 (19) 1-1/2 to 2-1/4 (38 to 57) 1/4 to 1 (6 to 25) 135°F(2) (57°C)or 165°F(3) (74°C) Notes: 1. Face of fitting to ceiling dimensions are based on a nominal thread make up. Verify dimensions based on fitting and thread sealing method prior to installation. A 1/2” x 1/2” brass nipple extension (Reliable P/N 6999991900) is available where necessary for replacement of existing sprinklers. 2. For use with 165°F (74°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F (38°C). 3. For use with 212°F (100°C) temperature rated sprinklers with the Maximum Ceiling Temperature does not exceed 150°F (66°C). Table JInstallation Dimensions Installation Model RFC series sprinklers are intended to be installed in ac- cordance with NFPA 13, NFPA 13R, or NFPA 13D, as well as the requirements of applicable authorities having jurisdiction. Mod- el RFC series sprinklers must not be installed in ceilings with positive pressure in the space above. Ensure that the 4 slots in the cup are open and unobstructed following installation. Model RFC series sprinklers are shipped with a protective cap that should remain on the sprinkler until installed. The protective cap should be replaced following installation of the sprinkler and permanently removed only when the cover plate is installed and the sprinkler system is placed in service following construction. Model RFC series sprinklers are installed with the Model FC wrench. The use of any other wrench to installed Model RFC se- ries sprinklers is not permitted and may damage the sprinkler. Temporarily remove the protective cap during installation of the sprinkler. Insert the Model FC wrench over the sprinkler until the wrench engages the body. Do not wrench any other part of the sprinkler/cup assembly. The Model FC wrench is designed to be turned with a standard 1/2” square drive. Tighten the sprin- kler into the fitting after applying a PTFE based thread sealant to the sprinkler’s threads. Recommended installation torque is 8 to 18 ft/lb (11 to 24 N/m). Do not exceed the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or im- pairment of the sprinkler. Use care when inserting or removing the wrench from the sprinkler to avoid damage to the sprinkler. Install the cover plate by hand by pushing the cover plate into the cup and turning the cover in the clockwise direction until it is tight against the ceiling. Application Model RFC series sprinklers are intended for installation where residential sprinklers are permitted or required by NFPA 13, NFPA 13R, and NFPA 13D. The sprinklers are concealed pen- dent residential sprinklers. Model RFC 30, RFC43, and RFC49 sprinklers are available in ordinary temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (38°C). Model RFC58 sprinklers are available in either ordinary or in- termediate temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (38°C) or 150°F (66°C), respectively. Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents Model RFC30, RFC43, RFC49, and RFC58 sprinklers are covered by U.S. Patent No. 9,248,327 and U.S. Patent No. 7,275,603. Model RFC30 and RFC43 sprinklers are additionally covered by U.S. Patent No. 8,776,903. Ordering Information Specify the following when ordering. Sprinkler • Model (RFC30, RFC43, RFC49, RFC58) • Temperature Rating Cover Plate • Model RFC • Temperature Rating • Finish (See Table H) Sprinkler Wrench • Model FC Maintenance Model RFC series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Replace any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-oper- ation. Bulletin 006 Rev. K February 2017 Page 7 of 7 www.reliablesprinkler.com Model FC Listings and Approvals Listed by Underwriters Laboratories, Inc. and UL Certified for Canada (cULus) UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Wrench P/N 9999970261 victaulic.com 10.81 5662 Rev H Updated 03/2017 © 2017 Victaulic Company. All rights reserved. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. 1.0 PRODUCT DESCRIPTION • Available Sizes: 2 – 12"/50 – 300 mm • cULus Listed, LPCB Listed, FM and VdS Approved for service up to 300 psi/2068 kPa /20 bar. • Designed for fire protection services only. • Features a weatherproof actuator housing Approved for indoor and outdoor use. • Actuation options: Hand wheel (2 – 12”/50 – 300 mm) • Exclusively for use with pipe and Victaulic products which feature ends formed with the Victaulic Original Groove System (OGS) groove profile (see section 7.0 for Reference Materials). 2.0 CERTIFICATION/LISTINGS 104j/04 NOTES • Refer to Victaulic submittal publication 10.01 for details G410001 FireLock® Butterfly Valve Series 705 with Weatherproof Actuator 10.81 1 System No.Location Submitted By Date Spec Section Paragraph Approved Date 10.81 5662 Rev H Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 2.1 CERTIFICATION/LISTINGS Approval/Listing Service Pressures Series 705 Butterfly Valve Size cULus FM Vds LPCB 2 50 up to 300psi/2068kPa n/a up to 300psi/2068kPa up to 300psi/2068kPa 2 ½ 65 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 76.1 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 3 80 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 4 100 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 5 125 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 139.7 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 6 150 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 165.1 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 8 200 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 10 250 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 12 300 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 3.0 SPECIFICATIONS – MATERIAL Body: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 End Face, 2 – 6”/50 – 150 mm: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 Seal Retainer, 8 – 12”/200 – 300 mm: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 Body Coating: Black alkyd enamel Disc: Ductile Iron conforming to ASTM A-536, Grade 65-45-12, with electroless nickel coating conforming to ASTM B-733 Seat: Grade “E” EPDM Stems: 416 stainless steel conforming to ASTM A-582 Stem Seal Cartridge: C36000 brass Bearings: Stainless steel with TFE lining Stem Seals: EPDM Stem Retaining Ring: Carbon steel Actuator: 2 – 8"/50 – 200 mm: Brass or bronze traveling nut on a steel lead screw, in a ductile iron housing 10 – 12"/250 – 300 mm: Steel worm and cast iron quadrant gear, in a cast iron housing 2 victaulic.com 10.81 5662 Rev H Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 4.0 DIMENSIONS Series 705 F G E A D ØH B C J Size Dimensions Nominal Actual Outside Diameter E to E A B C D E F G DIA H J inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm 2 2.375 4.25 2.28 6.41 ––4.00 4.22 4.50 2.1260.3 60.3 108.0 57.9 162.8 101.6 107.2 114.3 53.8 2 ½2.875 3.77 2.28 7.54 ––4.00 4.22 4.50 1.777373.0 95.8 57.9 191.5 101.6 107.2 114.3 45.0 76.1 mm 3.000 3.77 2.28 7.54 ––4.00 4.22 4.50 1.7776.1 95.8 57.9 191.5 101.6 107.2 114.3 45.0 3 3.500 3.77 2.53 7.79 ––4.50 4.22 4.50 1.7788.9 88.9 95.8 64.3 197.9 114.3 107.2 114.3 45.0 108 mm 4.250 4.63 2.88 8.81 ––5.50 4.22 4.50 2.20108.0 117.6 73.2 223.8 139.7 107.2 114.3 55.9 4 4.500 4.63 2.88 8.81 ––5.50 4.22 4.50 2.20114.3 114.3 117.6 73.2 223.8 139.7 107.2 114.3 55.9 133 mm 5.250 5.88 3.35 10.88 ––6.56 6.19 6.30 2.58133.0 149.4 85.1 276.4 166.6 157.2 160.0 65.5 139.7 mm 5.500 5.88 3.35 10.88 ––6.56 6.19 6.30 2.58139.7 149.4 85.1 276.4 166.6 157.2 160.0 65.6 5 5.563 5.88 3.35 10.88 ––6.56 6.19 6.30 2.58141.3 141.3 149.4 85.1 276.4 166.6 157.2 160.0 65.5 159 mm 6.250 5.88 3.84 11.38 –0.41 7.52 6.19 6.30 2.58159.0 149.4 97.5 289.1 10.4 191.0 157.2 160.0 65.5 165.1mm 6.500 5.88 3.84 11.38 –0.41 7.52 6.19 6.30 2.58165.1 149.4 97.5 289.1 10.4 191.0 157.2 160.0 65.5 6 6.625 5.88 3.84 11.38 –0.41 7.52 6.19 6.30 1.90168.3 168.3 149.4 97.5 289.1 10.4 191.0 157.2 160.0 48.3 8 8.625 5.33 5.07 13.53 0.80 1.47 10.00 6.19 8.10 2.33219.1 219.1 135.4 128.8 343.6 20.3 37.3 254.0 157.2 205.7 59.2 10 10.750 6.40 6.37 15.64 1.41 1.81 12.25 8.10 9.00 –273 273.0 162.6 161.8 397.3 35.8 46.0 311.2 205.7 228.6 12 12.750 6.50 7.36 16.64 2.30 2.80 14.25 8.10 9.00 –323.9 323.9 165.1 186.9 422.7 58.4 71.1 362.0 205.7 228.6 NOTE • Optional ½"/15 mm tap available. Contact Victaulic for details. 3 victaulic.com 10.81 5662 Rev H Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE Series 705 The chart expresses the frictional resistance of Victaulic Series 705 Butterfly Valve in equivalent feet/meters of straight pipe. Nominal Size Outside Diameter Equivalent mm inches mm inches Feet/m of pipe 2 2.375 65060.3 1.8 2 ½2.875 665 73.0 1.8 76.1 mm 3.000 676.1 1.8 3 3.500 78088.9 2.1 4 4.500 8100114.3 2.4 108 mm 108 mm 82.4 5 5.563 12125141.3 3.7 133 mm 133 mm 123.7 139.7 mm 5.500 12139.7 3.7 6 6.625 14150168.3 4.2 159 mm 159 mm 144.3 165.1 mm 6.500 14165.1 4.2 8 8.625 16200219.1 4.9 10 10.750 18250273.0 5.5 12 12.750 19300323.9 5.8 4 victaulic.com 10.81 5662 Rev H Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 5.1 PERFORMANCE Series 705 CV values for flow of water at +60°F/+16°C through a fully open valve are shown in the table below. For additional details, contact Victaulic. Formulas for Cv values Formulas for Kv values P = Q 2 Cv2 Q = Cv x P Where: Q = Flow (GPM) P = P ressure Drop (psi) Cv = Flow Coecient P = Q 2 Cv2 Q = Cv x P Where: Q = Flow (GPM) P = P ressure Drop (psi) Cv = Flow Coecient Q = Flow (m3/hr) P = Pressure Drop (Bar) Kv = Flow Coecient Where: Q = Flow (m3/hr) P = Pressure Drop (Bar) Kv = Flow Coecient Where: Valve Size Full Open Valve Size Full Open Nominal Size Actual Outside Diameter Flow Coefficient Nominal Size Actual Outside Diameter Flow Coefficient inches mm inches mm Cv inches mm inches mm Kv 2 2.375 170 2 2.375 1475060.3 50 60.3 2 ½2.875 260 2 ½2.875 2256573.0 65 73.0 76.1 mm 3.000 260 76.1 mm 3.000 22576.1 76.1 3 3.500 440 3 3.500 3808088.9 80 88.9 4 4.500 820 4 4.500 710100114.3 100 114.3 108 mm 108 mm 820 108 mm 108 mm 710 5 5.563 1200 5 5.563 1040125141.3 125 141.3 133 mm 133 mm 1200 133 mm 133 mm 1040 139.7 mm 5.500 1200 139.7 mm 5.500 1040139.7 139.7 6 6.625 1800 6 6.625 1560150168.3 150 168.3 159 mm 159 mm 1800 159 mm 159 mm 1560 165.1 mm 6.500 1800 165.1 mm 6.500 1560165.1 165.1 8 8.625 3400 8 8.625 2940200219.1 200 219.1 10 10.750 5800 10 10.750 5020250273.0 250 273.0 12 12.750 9000 12 12.750 7790300323.9 300 323.9 5 victaulic.com 10.81 5662 Rev H Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 6.0 NOTIFICATIONS WARNING • Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. • Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. • Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Switch and Wiring 1. The supervisory switch contains two single pole, double throw, pre-wired switches. 2. Switches are rated: 10 amps @ 125 or 250 VAC/60 Hz 0.50 amps @ 125 VDC 0.25 amps @ 250 VDC 3. Switches supervise the valve in the “OPEN” position. 5. One switch has two #18 insulated wires per terminal, which permit complete supervision of leads (refer to diagrams and notes below). The second switch has one #18 insulated wire per terminal. This double circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve is installed. 6. A #14 insulated ground lead (green) is provided. Switch #1 = S1 For connection to the supervisory circuit of a UL Listed alarm control panel Switch #2 = S2 Auxiliary switch that may be connected to auxiliary devices, per the authority having jurisdiction S1 {Normally Closed: (2) Blue Common: (2) Yellow S2 {Normally Closed: Blue with Orange StripeNormally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe NOTES • The above diagram shows a connection between the common terminal (yellow – S1 and yellow-with-orange stripe – S2) and the normally closed terminal (blue – S1 and blue-with-orange stripe – S2). In this example, the indicator light and alarm will stay on until the valve is fully open. When the valve is fully open, the indicator light and alarm will go out. Cap off any unused wires (e.g. brown with orange stripe). • Only S1 (two leads per terminal) may be connected to the fire alarm control panel. • The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per NFPA 70 (NEC). CONDUIT ½" NPT CONDUIT CONNECTORS UL LISTEDJUNCTION BOX WIRE NUTS FIRE ALARM CONTROL PANEL SUPERVISORY CIRCUIT N.C.NO.COM. TO END-OF-LINE RESISTOR,OR NEXT INDICATOR BELLORHORNVOLTAGE SOURCE Switch 1: 2 leads per terminalSwitch 2: 1 lead per terminal SWITCHCONTACT RATING:10A AT 125 AND250VAC,0.5A AT 125 VDC,0.25 AT 250 VDC S1 S2 6 victaulic.com 10.81 5662 Rev H Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com User Responsibility for Product Selection and SuitabilityEach user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms “Patented” or “Patent Pending” refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. NoteThis product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. TrademarksVictaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 7.1 REFERENCE MATERIALS 10.01: Regulatory Approval Reference Guide 29.01: Terms and Conditions/Warranty I-100: Field Installation Handbook 7 victaulic.com