HomeMy WebLinkAboutPEC140020_sscv - A000_1415033160.pdfScale
Date
Drawn By
Project Number
NOT FOR CONSTRUCTION
9/26/2014 4:04:39 PM
A000
COVERSHEET
SKI AND
SNOWBOARD
CLUB VAIL
.MEW
JULY 1, 2014
SSCV
GENERAL NOTES:
1. DO NOT SCALE DRAWINGS.
2. VERIFY ALL DIMENSIONS, CONDITIONS, AND UTILITY LOCATIONS PRIOR TO BEGINNING ANY
WORK OR ORDERING ANY MATERIALS. NOTIFY ARCHITECT OF ANY CONFLICTS OR
DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY.
3. AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY RESOLVED WITH WRITTEN
APPROVAL FROM THE ARCHITECTS BEFORE CONSTRUCTION CONTINUES IN THESE
PARTICULAR AREAS.
4. PLAN DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF STEEL, TIMBER, STUD
COLUMNS, OR FACE OF CONCRETE UNLESS OTHERWISE NOTED. SECTION AND ELEVATION
DIMENSIONS ARE TO TOP OF CONCRETE, TOP OF PLYWOOD, OR TOP OF WALL PLATES OR
BEAMS UNLESS OTHERWISE NOTED.
5. PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. LOCATIONS INCLUDE
BUT ARE NOT LIMITED TO CEILING AND WALL MOUNTED FIXTURES, TOILETS, TOILET
ACCESSORIES, CABINETRY, COUNTERTOPS, SHELVES, CLOSET RODS AND FALSE BEAMS.
6. REFER TO FLOOR PLANS FOR DOOR LOCATIONS. REFER TO DOOR SCHEDULE FOR DOOR
TYPES.
7. REFER TO FLOOR PLANS FOR WINDOW LOCATIONS. REFER TO WINDOW SCHEDULE FOR
WINDOW TYPES.
8. COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT WITHIN CEILING FLOOR
AND WALL SPACES. VERIFY WITH ARCHITECT WHEN DIVERTING FROM DRAWINGS.
9. IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY THE CONTRACTOR
FOR CONSTRUCTION OF ANY ASPECT OF THE PROJECT, THEY SHALL IMMEDIATELY NOTIFY THE
ARCHITECT. FAILURE TO GIVE 10 DAY NOTICE TO ARCHITECT SHALL NOT CONSTITUTE A DELAY
IN THE PROJECT.
10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL APPLICABLE
CODES AND OBTAINING ALL PERMITS AND REQUIRED APPROVALS. THIS PROJECT IS
GOVERNED BY THE IBC, IFC, IMC, IPC, NEC, ET AL. 2012 EDITIONS . COMPLIANCE IS
MANDATORY. THE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT WORK THAT DOES NOT
CONFORM TO ALL RELEVANT CODES INCLUDING IN IBC AND ALL LOCAL AND REGIONAL
CODES.
11. THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL FIELD COORDINATE AND
OBTAIN APPROVALS FROM THE ARCHITECT/ENGINEER BEFORE ANY CUTTING, NOTCHING, OR
DRILLING OF ANY CAST-IN-PLACE CONCRETE, STRUCTURAL FRAMING, OR ANY OTHER
STRUCTURAL ELEMENTS WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE
CONSTRUCTION.
12. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING GRADES AND SCALE OUT THE
BUILDING FOOTPRINT FOR OWNER AND ARCHITECT APPROVAL PRIOR TO BEGINNING ANY SITE
WORK.
13. THE OWNER HAS BEEN ADVISED THAT DUE TO HARSH WINTER CONDITIONS, ROOF & DECK
SURFACES MUST BE MAINTAINED REASONABLE FREE OF ICE & SNOW TO ENSURE MINIMAL
PROBLEMS WITH THESE SURFACES.
14. SUBSTITUTIONS OF "EQUAL" PRODUCTS WILL BE ACCEPTABLE WITH ARCHITECT'S
WRITTEN APPROVAL.
15. IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE GENERAL CONTRACTOR
AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, MATERIALS TRANSPORTATION, SUPPLIES,
EQUIPMENT, ETC. TO OBTAIN A COMPLETE JOB WITHIN THE RECOGNIZED STANDARDS OF THE
INDUSTRY.
16. ALL CONSTRUCTION IS TO FIT WITHIN THE BUILDING ENVELOPE AND/OR OUTSIDE
SETBACKS WITHOUT CREATING EASEMENTS. NOTIFY ARCHITECT IMMEDIATELY OF ANY
DISCREPANCIES.
17. THE GENERAL CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS OF ALL EXISTING
UTILITIES. ALL UTILITIES SHALL BE LOCATED TO MINIMIZE EXCAVATION AND VEGETATION
IMPACTS TO THE SITE.
18. THE GENERAL CONTRACTOR SHALL MINIMIZE THE LIMITS OF EXCAVATION AND TAKE
ADEQUATE MEASURES TO PROTECT ALL VEGETATION BEYOND THE LIMITS OF EXCAVATION.
ALL AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH THE NON-DISTURBED
LANDSCAPE EXCAVATION. ALL AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND
WITH THE NON-DISTURBED LANDSCAPE.
19. THE SOILS REPORT IS AVAILABLE FROM OWNER'S SOILS ENGINEER.
20. GENERAL CONTRACTOR SHALL VERIFY ALL SITE DEVELOPMENT WITH LANDSCAPE
CONSTRUCTION DOCUMENTS. THE SITE PLAN IS FOR GRADING AND LANDSCAPE PLAN IS FOR
LAYOUT; ANY DISCREPANCIES VERIFY WITH ARCHITECT.
ARCHITECT:
K.H. WEBB ARCHITECTS P.C.
710 WEST LIONSHEAD CIR., SUITE A
VAIL, CO 81657
PH. 970.477.2990
FX. 970.477.2965
Michael@khwebb.com
CONTACTS:
KYLE H. WEBB / MIKE WILCOX
CODE:
INTERNATIONAL BUILDING CODE 2012
ZONING:
SKI BASE/RECREATION-2
OCCUPANCY CLASSIFICATION:
CLUB: GROUP B, CONDOMINIUMS: R-2
BUILDING FULLY SPRINKLED
CONSTRUCTION TYPE:
TYPE II-A
SEPARATION:
1 HOUR FIRE BARRIER
GENERAL NOTES: PROJECT SUMMARY:
PROJECT TEAM:
DRAWING INDEX:
SKI AND SNOWBOARD CLUB VAIL PEC RESUBMITTAL SEPTEMBER 26, 2014
CIVIL
TS 01 TOPOGRAPHIC SURVEY
C1 SITE AND GRADING PLAN
C2 SITE AND GRADING PLAN
C3 AUTO-TURN MOVEMENTS
D1 DRAINAGE PLAN EXISTING
D2 DRAINAGE PLAN PROPOSED
LANDSCAPE
L-1 LANDSCAPE PLAN
ARCHITECTURAL
A 010 AREA PLANS AND CALCULATIONS
A 100 GARAGE FLOOR PLAN
A 101 CLUB LEVEL ONE FLOOR PLAN
A 102 CLUB LEVEL TWO FLOOR PLAN
A 103 CONDO LEVEL THREE FLOOR PLAN
A 104 CONDO LEVEL FOUR FLOOR PLAN
A 105 ROOF PLAN
A 110 GARAGE REFLECTED CEILING PLAN
A 111 CLUB LEVEL ONE REFLECTED CEILING PLAN
A 112 CLUB LEVEL TWO REFLECTED CEILING PLAN
A 113 CONDO LEVEL THREE REFLECTED CEILING PLAN
A 114 CONDO LEVEL FOUR REFLECTED CEILING PLAN
A 201 NORTH AND WEST ELEVATIONS
A 202 SOUTH AND EAST ELEVATIONS
A 301 BUILDING SECTIONS
A 302 BUILDING SECTIONS
A 901 BUILDING PERSPECTIVES
A 902 BUILDING PERSPECTIVES
CONTRACTOR:
J.L. VIELE CONSTRUCTION
1000 S. FRONTAGE ROAD WEST
SUITE 202
VAIL, CO 81657
PH. 970.476.3082
FX. 970.476.3423
LANDSCAPE ARCHITECT:
DENNIS ANDERSON
LANDSCAPE ARCHITECTURE
PO BOX 1387
EDWARDS, CO 81632
PH. 970.926.7200
FX. 970.926.7201
CIVIL ENGINEER:
MARTIN/MARTIN, INC.
225 MAIN STREET
SUITE C101
EDWARDS, CO 81632
PH: 970.926.6007
CONTACT: MARK LUNA /
JUSTIN YARNELL
STRUCTURAL ENGINEER:
MONROE & NEWELL ENGINEERS
70 BENCHMARK ROAD
SUITE 204
PO BOX 1597
AVON, CO 81620
PH. 970.949.7768
CONTACT: HANNES SPAEH
No. Description Date
02 P.E.C. RESUBMITTAL 8-25-14
01 P.E.C. SUBMITTAL 7-14-14
03 P.E.C. RESUBMITTAL 9-26-1403 P.E.C. RESUBMITTAL 9-26-14
PEC
APPROVED
10/27/2014 12:00:00 AM