HomeMy WebLinkAboutPEC140031_Vail 21 301 A3.50_1410281940.pdfA3.50
02
TYPICAL CABINET DIMENSIONS
NOTE: ALL CABINET DIMENSIONS GIVEN ARE NOMINAL. SCHEDULED
CEILING HEIGHT
84"
60"
54"
48"
36"
34"
30"
FF
2' - 0"
2' - 0 3/4"
BASE CABINET COUNTERTOP
3/4" MIN
1 1/2" MAX
1/8”
SCRIBE TO
WALL
FILLER PANEL
LINE OF WALL
DOOR
PLAN - WALL
FILLER PANEL
AT END WALL
A
PLAN - END PANEL
B
DOOR
FLUSH
END PANEL
ARCHITECTURAL CABINET TYPICAL DETAILS
APRON
COUNTERTOP
1 1/4”
1 1/2” 30" AFF
SECTIONS - KNEE SPACE/APRON
C
PLAN - INSIDE CORNER
FILLER PANELS BETWEEN
ADJACENT CABINETS
D
4" MAX
2 1/4" MIN
4" MAX
2 1/4" MIN1/8”
DOOR
DOOR OR
DRAWER
FILLER
PANEL
1/8” CABINET
PULL
DRAWER
FRONT
DOOR
STRETCHER
SECTION - DOOR TO DRAWER
DRAWER TO DRAWER SIM
E
SECTION - OPEN
CABINET TO DRAWER
F
CABINET
PULL
DRAWER
FRONT
END PANEL
OR CABINET
BEYOND
STRETCHER
1 1/2”
1/8” CABINET
PULL
DOOR
COUNTERTOP
1/8”
1/8” 2 1/2”
DOOR
VALANCE
CABINET
PULL
SECTION -
COUNTERTOP WITH
DOOR BELOW
G
SECTION - UPPER CABINET
WITH DOORS AT VALANCE
H 2 3/8”
END
PANEL
CABINET
BOTTOM
SECTION - UPPER CABINET
AT EXPOSED SIDE
J
1/8” 1/8”
DOOR
CABINET
PULL
PLAN - CABINET TO
CABINET AT DOORS
K
PLAN - DOOR TO
DOOR
L
1/8”
DOOR
CABINET
PULL
1/8”
FIN CLG
FASCIA
PANEL
WITH
INTEGRAL
SUPPORT
END PANEL
SECTION - UPPER
CABINET FASCIA
PANEL RETURN
M
SCRIBE TO
BACK WALL
CABINET
BOTTOM
LINE OF WALL
SECTION - UPPER CABINET -
BOTTOM OF BACK WALL
O MIN
1”
CABINET
COUNTERTOP
LINE OF WALL
PLAN - CASEWORK
AT WALL ADJACENT
P
END
PANEL
SCRIBE
TO BACK
WALL
END PANEL AT WALL
R
BASE
CABINET
COUNTERTOP
COUNTERTOP EXTENSION
AT END OF BASE CABINET
S 1/8”
4”
4”
DOOR
EXTEND WALL
BASE UNO
FLOOR
SECTION - CABINET
DOOR AT BASE
T
EQUIP
END
PANEL
SECTION - END CAP
U
1/8”
FIN CLG
FASCIA PANEL
WITH INTEGRAL
SUPPORT AT
36" OC MAX
(MIN 2)
DOOR
UPPER CABINET FASCIA
PANEL CLOSURE
V
END
PANEL
SECTION - END CAP
W
END PANEL
LINE OF
BACK WALL
SCRIBE TO
WALL
PLAN - END PANEL
AT BACK WALL
X
1/8”
CLEAR
MUTE
2” CLEAR
MUTE
CLEAR
MUTE
CABINET LEGEND
CABINET ELEVATION LEGEND
SCHEDULED
CLG HEIGHT
84"
60"
54"
48"
36"
34"
30"
FF
A
L
K
G G
P
A
K
L
L
K NV
B
36
36
30
I
O H
T
B
U
U
C
C F
R E
AS
EQUIP
KS
36a 36 18 18 30
SS
M
X
J X
S
FURR DOWN OR
FASCIA PANEL
ADJUSTABLE
SHELF INDICATION
COUNTERTOP
DESIGNATION IF
OTHER THAN
PLASTIC LAMINATE
CABINET
ELEVATION
ABBREVIATION
CABINET WIDTH
AND ACCESSORY
VIEW ICON INDICATES
ORIENTATION OF
VIEW ON PLAN
ROOM NAME
ROOM NUMBER
CABINET ELEVATION LEGEND SCHEDULED CLG HEIGHT
84"
60"
54"
48"
36"
34"
30"
FF
KS
ROOM NAME
ROOM NUMBER
A
A
P
K
L
N
V
B
H O
I G
C
K
L
B W
Q
T FURR DOWN OR
FASCIA PANEL
ADJUSTABLE
SHELF INDICATION
CABINET
ELEVATION
ABBREVIATION
VIEW ICON
INDICATES
ORIENTATION OF
VIEW ON PLAN
CABINET GENERAL NOTES
1. CABINET WIDTHS TO BE BASED ON MODULE INCREMENTS OF 3" UNO.
2. PROVIDE FILLER PANELS TO FINISH OUT TO SCRIBE CABINETS TO WALL.
3. PROVIDE FILLER PANELS AND TRIM WHERE EQUIPMENT IS LOCATED WITHIN CABINETS.
4. PROVIDE FINISHED END PANELS END RETURNS AT OPEN ENDED CABINETS, KNEE SPACES, AND
ACCESSIBLE SINKS.
5. WHEN FILLER PANELS ARE REQUIRED AT BOTH ENDS OF CASEWORK TERMINATION, BOTH FILLER PANELS
SHALL BE EQUAL WIDTH.
FASCIA PANEL JOINTS
8'-0" MAX BETWEEN
TASK LIGHTING
PROJECT NUMBER
ISSUE DATE
710 W. COLFAX; DENVER, C0 80204
REVISION
SHEET TITLE
ISSUE
SHEET NO.
521 EAST LIONSHEAD CIRCLE
VAIL, COLORADO 81657
A3.50
MILLWORK DETAILS
14040.000
TENANT IMPROVEMENTS
SUITE 301 & 302
CONSTRUCTION
DOCUMENTS
AUGUST 04, 2014
No. Description Date
PEC
APPROVED
9/8/2014 12:00:00 AM