HomeMy WebLinkAboutPEC160009_E2.1_1465853400.pdf1 2 3
A
B
C
A.1
B.1
C.1
1.1
2.1
3.1
4
D
1. EXTERIOR LIGHTING SHALL BE CONTROLLED BY
LIGHTING CONTROL PANEL (LCP).
NOTES:
LIGHTING CONTROL PANEL (LCP). RE: A/E1.0 FOR
LIGHTING CONTROL PANEL DIAGRAM.
PROVIDE WATTSTOPPER ULTRASONIC LINE
VOLTAGE CEILING SENSOR.
PROVIDE WATTSTOPPER PASSIVE INFRARED
WALL SWITCH.
PROVIDE ELECTRICAL CONNECTION TO AUTOMATIC
PLUMBING FIXTURES.
PROVIDE 4-SQUARE JUNCTION BOX, WITH BLANK
COVER, FOR FUTURE POSSIBLE BASEBOARD
HEATER. PROVIDE 3/4" CONDUIT FROM JUNCTION
BOX TO ELECTRICAL PANEL WITH PULL STRING.
JUNCTION BOX FOR FUTURE HEAT
CONTROL/THERMOSTAT. PROVIDE 1/2" RACEWAY,
WITH PULL STRING TO HEATER LOCATION.
FLAG NOTES:
SCALE:
RESTROOM ELECTRICAL PLAN
1/4" = 1'-0"
PANEL 'P1'
W1
W1
W1
W1
W2
W2
S1 S1
S1
S1
S1
LUMINAIRE SCHEDULE
TYPE DESCRIPTION MOUNTING LUMENS LAMPS INPUT WATTS VOLT MANUFACTURER CATALOG NUMBER
SPECIFIC
NOTES
QTY TYPE
W1 4FT WALL MOUNTED LED VANDAL RESISTANT SURFACE
FIXTURE, VERIFY FINISH WITH ARCHITECT
SURFACE 2080 -- LED AS SUPPLIED,
3500K
30 UNV PHILIPS LPLS4L30-35K-UNV-F1
W2 2FT WALL MOUNTED LED VANDAL RESISTANT SURFACE
FIXTURE, VERIFY FINISH WITH ARCHITECT
SURFACE 2200 -- LED AS SUPPLIED,
3500K
30 UNV PHILIPS LPLS2L30-35K-UNV-F1
S1 5" ROUND, LOW PROFILE, SURFACE MOUNTED LED
DOWNLIGHT
SURFACE 650 -- LED AS SUPPLIED,
2700K
9.5 120 PHILIPS S5R827K7AL
GENERAL NOTES:
A. THE LUMINAIRE SCHEDULE CAN NOT BE USED INDEPENDENTLY OF THE DRAWINGS AND SPECIFICATIONS TO OBTAIN LUMINAIRE COSTS. THE INDIVIDUAL ESTABLISHING LUMINAIRE COSTS SHALL NOT QUOTE
PRICING WITHOUT FIRST SEEING APPLICABLE ELECTRICAL DRAWINGS AND ELECTRICAL DIVISION SPECIFICATIONS. THE CONTRACTOR IS REPONSIBLE FOR PROVIDING NECESSARY DRAWINGS AND
SPECIFICATIONS TO THE INDIVIDUAL QUOTING LUMINAIRE PRICING.
B. REFER TO DRAWINGS FOR FIXTURES REQUIRING EMERGENCY BATTERY BACKUP OPTION (SHOWN BY HATCH IN/OVER SYMBOL). MINIMUM LIGHT OUTPUT FOR EM BALLAST SHALL BE 600 LUMENS.
C. ALL FLUORESCENT LAMPS ARE TO BE 3500° KELVIN COLOR TEMPERATURE
SPECIFIC NOTES:
(1)
(2)
(3)
(4)
1
1
OS
OS
2
2 2
S
O
S O
3
3
3
MECHANICAL EQUIPMENT SCHEDULE
MARK DESCRIPTION VOLT /
PHASE
HP WATTS FLA DISCONNECT/
FUSE SIZE
FEEDER SPECIFIC NOTES
BB-1 BASEBOARD HEATER 120/1 -- 500 4.2 1P MOTOR RATED
SWITCH
(2#12 & 1#12G) 3/4"C
WH-1 INTANTANEOUS WATER
HEATER
240/1 -- 13000 54 2P MOTOR RATED
SWITCH
(3#4 & 1#10G) 1"C
GENERAL NOTES:
A. SEE SPECIFICATIONS FOR ELECTRICAL DIVISION AND MECHANICAL DIVISION MOTOR STARTER COORDINATION.
B. PROVIDE PHASE PROTECTION FOR ALL THREE PHASE MOTORS ABOVE 7-1/2 HP.
C. PROVIDE ALL EXTERIOR DISCONNECTS WITH NEMA 3R RATING.
D. WHEN EQUIPMENT IS LISTED WITH ONLY A HORSEPOWER RATING THE DISCONNECT AND FEEDER ARE SIZED PER THE N.E.C.
SPECIFIC NOTES:
(1)
(2)
(3)
(4)
BB
1
BB
1
WP WP
+48"
+48"
+48"
+48"
WH
1
WH
1
J
J
J
J
4
4
4
4
4
J
4
CONTROLLED
BY LCP J
J
5
5
5
6
6
6
J
J
C
SHEET NUMBER
PROJECT NUMBER:
1
5431
2 3 4 5 6 7
A
B
C
D
E
C O P Y R I G H T D E S I G N W O R K S H O P, I N C.
F
8 9
1 2 3 4 5 6 7 8 9
100%
DESIGN DEVELOPMENT
DOCUMENTS
COPYRIGHT 2016
B
ANZE
G
EAUDIN
(970) 949-6108
(303) 278-3820
(970) 221-5691
(505) 323-9070
(307) 739-3944
Vail:
Denver:
Fort Collins:
Albuquerque:
Jackson:
www.bgce.com
DESIGN
DATE #
DESCRIPTION
ISSUE DATE:
REVIEWED: DRAWN:
WORKSHOP
REVISIONS
REDEVELOPMENT
2900
MANNS
RANCH
ROAD
VAIL, COLORADO
W W W . D E S I G N W O R K S H O P . C O M
Landscape Architecture Land Planning
Urban Design Tourism Planning
Facsimile (970) 920-1387
(970) 925-8354
Aspen, CO 81611
120 E. Main St.
Asheville Aspen Austin Beijing Chicago
Denver Dubai Houston Lake Tahoe Los Angeles
February 12, 2016
BOOTH CREEK PARK
1309 ELKHORN DRIVE. VAIL, COLORADO. 81657
970.479.2158
E2.1
RESTROOM
ELECTRICAL
PLAN
BAS MAS
PEC APPROVED