HomeMy WebLinkAboutPEC160009_M1.0_1465853400.pdfSHOCK ABSORBER
STRAINER W/ BLOW-OFF VALVE
SAFETY RELIEF VALVE
PRESSURE GAUGE W/ PIG TAIL & COCK
THERMOMETER
PRESSURE - TEMP. TAP
AIR VENT
PIPE ANCHOR
FLEXIBLE CONNECTOR
PIPE EXPANSION JOINT
PIPE UNION
DOUBLE CHECK BACKFLOW PREVENTER
TEMPERATURE CONTROL VALVE (2-WAY)
FLOW BALANCING VALVE
GATE OR GLOBE VALVE IN RISER
FLOW CONTROL VALVE
BALL VALVE
PLUG OR BALANCING VALVE
CHECK VALVE
GLOBE VALVE
BUTTERFLY VALVE
TEMPERATURE CONTROL VALVE (3-WAY)
SOLENOID VALVE
90° ELBOW UP
TEE UP
TEE DOWN
SHUT OFF (BALL, GATE, BUTTERFLY)
PIPING SYMBOLS
90° ELBOW DN
S
HOSE BIBB
WALL HYDRANT
TEMPERATURE CONTROLLER OR SENSOR
FIXTURE CONNECTION SCHEDULE
HW CW WASTE VENT
:
1. SIZES SHOWN ARE MINIMUM PIPE SIZES TO A SINGLE FIXTURE. LARGER
SIZES MAY BE INDICATED ON PLANS WHERE REQUIRED.
2. MINIMUM DOMESTIC PIPE SIZE TO (2) OR MORE FIXTURES IS 3/4".
3. RE: MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR INDIRECT WASTE
SIZES.
4. WASTE AND VENT SIZES SHOWN ABOVE APPLY TO INDIVIDUAL VENTING ONLY.
WHERE ALLOWED, INDIVIDUAL VENT CONNECTIONS MAY BE OMITTED OR
SIZES MAY VARY WHEN CIRCUIT VENTS, COMMON VENTS, WASTE STACK
VENTS, WET VENTS, OR COMBINATION DRAIN AND VENT SYSTEMS ARE USED.
PRIOR APPROVAL FROM THE ENGINEER IS REQUIRED TO USE THESE
ALTERNATIVE VENTING METHODS.
5. PROVIDE TRAP PRIMER FOR ALL FLOOR DRAINS AND FLOOR SINKS NOT
LOCATED IN FOOD SERVICE AREAS.
6. MINIMUM SIZE FOR WASTE AND VENT PIPING BENEATH SLAB IS 2".
7. ALL FIXTURES LISTED ARE NOT NECESSARILY USED ON THIS PROJECT.
8. REFER TO APPLIANCE SCHEDULES (BY OTHERS) FOR ADDITIONAL PLUMBING
FIXTURE CONNECTIONS SUCH AS INST-HOTS, COFFEE MAKERS, AND
GARBAGE DISPOSALS.
9. PROVIDE ICE MAKER BOX ROUGH IN W/ 1/2"CW CONNECTION FOR ALL
REFRIGERATOR LOCATIONS.
ABBREV.
DRINKING FOUNTAIN / E.W.C. DF - 1/2" 1-1/2" 1-1/2"
FD FLOOR DRAIN - - 2" 1-1/2"
FS FLOOR SINK - - 3" 2"
HOSE BIB HB - - -3/4"
HAND SINK HS 1-1/2" 1-1/2"
1/2" 1/2"
LAVATORY LAV 1/2" 1-1/2" 1-1/2"
1/2"
MOP SERVICE BASIN MSB 3/4" 3" 2"
3/4"
SERVICE SINK SS 3" 2"
1/2" 1/2"
URINAL (BLOWOUT) UR 1" 2" 1-1/2"
-
URINAL (WASHDOWN)
UR
UR URINAL (WATERLESS)
3/4" 2" 1-1/2"
- 2" 1-1/2"
-
-
WATER CLOSET (FLUSH VALVE)
WC
WATER CLOSET (FLUSH TANK)
WCT
- 1" 4" 2"
- 1/2" 4" 2"
EQUIPMENT ABBREVIATIONS
AIR HANDLING UNIT
AHU
AIR SEPARATOR
AS
BOILER (HOT WATER)
B
BASE BOARD
BB
BUFFER TANK
BT
CONSTANT VOLUME BOX
CV
DISHWASHER EXHAUST FAN
DEF
ELECTRIC BASEBOARD HEATER
EBH
FURNACE
F
FAN COIL
FC
FAN POWERED BOX
FP
GLYCOL FEEDER
GF
HUMIDIFIER
HC HEATING COIL
HP HEAT PUMP
HX HEAT EXCHANGER
KITCHEN EXHAUST FAN
KEF
MAKE-UP AIR UNIT
MAU
MOTOR CONTROL CENTER
MCC
MIXING VALVE
MV
PUMP
P
RETURN (OR RELIEF) AIR FAN
RF
RADIANT ZONE
RZ
SNOWMELT AREA
SA
SUMP BASIN
SB
SUPPLY FAN
SF
STORAGE TANK
ST
THERMOSTATIC MIXING VALVE
TMV
UNIT HEATER
UH
VARIABLE VOLUME BOX
VV
WATER HEATER
WH
H
CHILLER
CH
COILING COIL
CC
CIRC PUMP
CP
CABINET UNIT HEATER
CUH
COOLING TOWER
CT
DUCT COIL
DC
ELECTRIC WATER HEATER
EWH
EVAPORATIVE COOLING UNIT
ECU
ENERGY RECOVERY UNIT
ERU
EXHAUST FAN
EF
EXPANSION TANK
ET
VARIABLE VOLUME BOX W/ REHEAT
VR
REFERENCE SAMPLE
FFI = FOR FURTHER INFORMATION
FCT = FOR CONTINUATION
RE: B/M400 FFI
REFER TO:
DRAWING NUMBER OR
DIAGRAM LETTER
SHEET NUMBER
PLAN ABBREVIATIONS
ABOVE FINISHED FLOOR
AIR ADMITTANCE VALVE
ABOVE FINISHED GRADE
AUTOMATIC
BUILDING
AAV
AFF
AFG
AUTO
BLDG
BETWEEN
COMMON (OR CLOSED)
CONTROLS CONTRACTOR
CONTINUATION DESIGN BUILD
B/N
C
CC
CDBBC
CUBIC FEET PER MINUTE (AIR FLOW RATE)
CEILING (OR COOLING)
CONCRETE
CONDENSATE
CONNECT (OR CONNECTION)
CONTRACTOR
CFM
CLG
CONC
COND
CONN
CONTR'R
CLEANOUT TO GRADE
COTG
DOMESTIC HOT WATER RECIRC
DWR
ENTERING AIR TEMPERATURE
ELECTRICAL CONTRACTOR
ENTERING WATER TEMPERATURE
EAT
EC
EWT
GENERAL CONTRACTOR
GC
GALLONS PER MINUTE (WATER FLOW RATE)
GPM
HOT WATER
IN LIEU OF
HW
ILO
LEAVING AIR TEMPERATURE
LEAVING WATER TEMPERATURE
LAT
LWT
MECHANICAL CONTRACTOR
MC
MANUFACTURER
NEW
MFG
(N)
NORMALLY CLOSED
NC
NOT IN CONTRACT
NORMALLY OPEN
NIC
NO
ON CENTER
OC
REQUIRED
REQ'D
REQUIREMENTS
REQ'MTS
SQUARE FOOT (FEET)
SF
THROW-AWAY (TRANSFER AIR)
TYPICAL
TA
TYP
UNLESS NOTED OTHERWISE
UNO
WALL CLEANOUT
WCO
WITH REGARD TO
WATER COOLED
TRANSFER
WRT
W/C
XFR
DIAMETER
Ø
BY CONTRACTOR
COLD WATER
CW
HOT WATER RECIRC
HWC
ABOVE
ABV
BELOW FINISHED GRADE
BFG
DOMESTIC WATER
DOMESTIC HOT WATER
DW
DHW
DOMESTIC HOT WATER RECIRC
DHR
FURNISHED BY OWNER
FBO
FLOOR CLEANOUT
FCO
FOR CONTINUATION
FCT
REFER TO:
RE:
WITH
W/
CLEANOUT
CO
FFI FOR FURTHER INFORMATION
WITHOUT
W/O
VENT THRU ROOF
VTR
NOTES
1. ALL SYMBOLS, ABBREVIATIONS, AND DESIGNATIONS
ON LEGEND SHEET ARE NOT NECESSARILY USED ON
THIS PROJECT.
2. THIS DRAWING SET CONSISTS OF DATA GENERATED, IN
PART, BY OTHER PARTIES. NOT ALL SYMBOLOGIES AND
NOTATION CONVENTIONS OCCURRING IN THIS
DRAWING SET ARE NECESSARILY DEFINED ON THESE
LEGENDS. CONSULT THE ENGINEER IN THE EVENT
SYMBOLOGY OR NOTATION INTERPRETATION IS
REQUIRED.
PLAN SYMBOLS
CONTROL PANEL/RADIANT MANIFOLD
DIAGRAM CONTINUATION REFERENCE
PLUMBING/HVAC RISER
POINT OF NEW CONNECTION
ACCESS PANEL
SECTION CUT LETTER/SHEET SHOWN ON
POINT OF DISCONNECTION
-
--
-
P
THERMOSTAT
T
H B
W H
TC
FLOOR DRAIN
FLOOR SINK
HORIZONTAL CLEANOUT
VERTICAL CLEANOUT
PIPING DESIGNATIONS
HEATING WATER SUPPLY (HIGH TEMP)
HEATING WATER RETURN (HIGH TEMP)
CHILLED WATER SUPPLY
CHILLED WATER RETURN
CONDENSER RETURN
DOMESTIC WATER
DOMESTIC HOT WATER
DOMESTIC HOT WATER (TEMP. SHOWN)
DHW RECIRCULATION
FIRE LINE
PRESSURIZED WASTE
PLUMBING VENT PIPE
WASTE PIPE
HEATING WATER SUPPLY (LOW TEMP)
HEATING WATER RETURN (LOW TEMP)
GROUND WATER SUPPLY
GROUND WATER RETURN
HEATING WATER SUPPLY
HEATING WATER RETURN
DRAIN PIPE
CLOSED CONDENSER SUPPLY
CLOSED CONDENSER RETURN
CONDENSER SUPPLY
PLUMBING PIPING
NON-SOFTENED DOMESTIC WATER
CR
CS
CCR
CCS
CHR
CHS
HWR
HWS
HWR(LT)
HWS(LT)
HWR(HT)
HWS(HT)
D
GWR
GWS
CW
HW
HWC
NS
140° HW
V
W
PW
F
SOLID DRAIN PIPE
DS
HYDRONIC PIPING
SUMP PUMP
SP
MECHANICAL SYSTEMS LEGEND
ABOVE SEA LEVEL
PROJECT ALTITUDE
8400'
PLUMBING FIXTURE SCHEDULE
SYMBOL TYPE A.D.A. FINISH
MANUFACTURER*
& MODEL #
FAUCET TRIM MFR.* &
MODEL #
ACCESSORIES REMARKS
SINK YES
VITREOUS
CHINA
KOHLER
K-15198-F & K-2035-1
- - -
TOILET YES
VITREOUS
CHINA
KOHLER
K-4405 & K-4670-CA
SLOAN OPTIMA
FLUSHOMETERS ROYAL
111-1.28
- -
URINAL YES
VITREOUS
CHINA
SLOAN
WEUS-1000.1001-0.125
- - -
MOP SINK NO
STAINLESS
STEEL
ADVANCE TABCO
9-OP-20
ADVANCE TABCO
K-240
- -
FLOOR DRAIN NO BRASS
ZURN
FD2201
- - -
FLOOR SINK NO
STAINLESS
STEEL
ZURN
Z1752
- - -
WALL HYDRANT - - WOODFORD B67 - FREEZELESS
WALL HYDRANT - - WOODFORD MB24 - - -
MANUFACTURERS:
FIXTURE: AMERICAN STANDARD, UNIVERSAL RUNDLE, FIAT STERN WILLIAMS
FAUCET: SPEAKMAN, DELTA, AMERICAN STANDARD, CHICAGO
DRAIN: JOSAM, WADE SMITH
GENERAL NOTES:
A:
B:
P1
P2
P3
P4
P5
P6
P7
P8
WATER HEATER SCHEDULE (ELECTRIC)
MARK TYPE
STORAGE
CAPACITY
(GAL.)
RECOVER
Y (GPH)
WATER
TEMP.
RISE (°F)
ELECTRICAL
MANUFACTURER*
& MODEL #
ACCESSORIES REMARKS
KW VOLT/
PH
WH-1 TANKLESS 0 0 65 13 240/1 RHEEM RTE 13 - -
MANUFACTURERS:
* A.O. SMITH, RUUD OR STATE EQUIVALENT
GENERAL NOTES:
A:
B:
ELECTRIC BASEBOARD HEATER
MARK TYPE
RATED
BTUH
ELECTRICAL
MANUFACTURER*
& MODEL #
ACCESSORIES REMARKS
BB-1
HEAVY-
DUTY
ELECTRIC
4.2 500 120/1
BERKO
OBD500
THERMOSTAT,
INTEGRAL DISCONNECT
28" LENGTH
MANUFACTURERS:
* QMARK, MARKEL, MARLEY, OR RUNTAL EQUIVALENT
GENERAL NOTES:
A:
1. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS IN FIELD PRIOR TO COMMENCEMENT OF WORK. REFER TO ARCHITECTURAL
DRAWINGS FOR ALL DIMENSIONS.
2. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT, OWNER, AND ENGINEER.
3. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PERFORM HIS/HER WORK IN CONFORMANCE WITH ALL APPLICABLE CODES,
ORDINANCES AND LIFE SAFETY FEATURES AS REQUIRED BY LOCAL, STATE, OR NATIONAL AUTHORITIES. THE CONTRACTOR
SHALL VERIFY WITH THE ARCHITECT IF MODIFICATION OF HIS/HER WORK IS REQUIRED FOR COMPLIANCE.
4. ALL WORK OF ALL TRADES MUST BE IN STRICT COMPLIANCE, OR EXCEED THE MINIMUM MATERIAL AND METHOD REQUIREMENTS
OF THE 2009 VERSION OF THE INTERNATIONAL BUILDING, MECHANICAL, PLUMBING, FUEL GAS, AND ENERGY CONSERVATION
CODES AND THE 2014 NATIONAL ELECTRICAL CODE, ALL LOCAL ORDINANCES AND AMENDMENTS AND MANUFACTURER'S
INSTALLATION RECOMMENDATIONS. IF A CONFLICT BETWEEN THOSE PUBLICATIONS EXISTS, THE MOST STRINGENT
REQUIREMENT SHALL APPLY.
5. SYSTEMS SHALL BE COMPLETE, OPERABLE, AND READY FOR CONTINUOUS OPERATION PRIOR TO ACCEPTANCE BY THE OWNER.
6. SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. PERFORM AT A MINIMUM ALL CODE REQUIRED TESTS OR SYSTEMS. IF
TESTS OF WORK ARE DEFECTIVE, CONTRACTOR SHALL MAKE CORRECTIONS NECESSARY AT NO ADDITIONAL COST TO OWNER.
7. ALL MATERIALS AND/OR EQUIPMENT SHALL BE HANDLED AND INSTALLED AS PER MANUFACTURER'S SPECIFICATIONS AND
RECOMMENDATIONS.
8. ALL FLOOR DRAINS AND FLOOR SINKS CONNECTED TO THE SEWER SYSTEM SHALL BE EQUIPPED WITH TRAP PRIMERS. PROVIDE
TRAP PRIMERS WITH BACKFLOW PREVENTERS AND CONNECT TO THE NEAREST COLD WATER PIPING ADJACENT TO A FLUSHING
FIXTURE. PROVIDE ELECTRONIC TRAP PRIMERS FOR ANY AREAS WHERE THE NEAREST ADJACENT FLUSHING FIXTURES ARE NOT
WITHIN A REASONABLE DISTANCE OR STRUCTURAL OBSTRUCTIONS PREVENT GRAVITY SLOPING OF TRAP PRIMER LINES.
ADDED COST OF ELECTRIC POWER FOR ELECTRONIC TRAP PRIMERS SHALL BE BORNE BY PLUMBING CONTRACTOR. INSTALL
ALL TRAP PRIMER VALVES AND ASSOCIATED SYSTEMS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
9. COORDINATE ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL, AND LANDSCAPE DRAWINGS PRIOR TO
INSTALLATION.
10. CAREFULLY VERIFY ELECTRICAL SERVICE VOLTAGE AND PHASE AVAILABLE.
11. MOUNT ALL STATS AT 48” AFF IN “ACCESSIBLE” AREAS, 4'6” AFF IN OTHER AREAS, UNLESS NOTED OTHERWISE. COORDINATE
LOCATION WITH WALL FINISH, AND TO AVOID CASEWORK, FURNITURE, DOOR SWINGS, HEAT SOURCES, AND EXTERIOR WALLS.
NOTIFY THE DESIGN TEAM CONSTRUCTION ADMINISTRATOR OF ANY CONFLICTS PRIOR TO BEGINNING THERMOSTAT
INSTALLATION.
12. REFER TO PLUMBING FIXTURE CONNECTIONS SCHEDULE FOR PIPE SIZES TO INDIVIDUAL PLUMBING FIXTURES.
GENERAL NOTES:
C
SHEET NUMBER
PROJECT NUMBER:
1
5431
2 3 4 5 6 7
A
B
C
D
E
C O P Y R I G H T D E S I G N W O R K S H O P, I N C.
F
8 9
1 2 3 4 5 6 7 8 9
100%
DESIGN DEVELOPMENT
DOCUMENTS
COPYRIGHT 2016
B
ANZE
G
EAUDIN
(970) 949-6108
(303) 278-3820
(970) 221-5691
(505) 323-9070
(307) 739-3944
Vail:
Denver:
Fort Collins:
Albuquerque:
Jackson:
www.bgce.com
DESIGN
DATE
#
DESCRIPTION
ISSUE DATE:
REVIEWED:
DRAWN:
WORKSHOP
REVISIONS
REDEVELOPMENT
2900
MANNS
RANCH
ROAD
VAIL, COLORADO
W W W . D E S I G N W O R K S H O P . C O M
Landscape Architecture Land Planning
Urban Design Tourism Planning
Facsimile (970) 920-1387
(970) 925-8354
Aspen, CO 81611
120 E. Main St.
Asheville Aspen Austin Beijing Chicago
Denver Dubai Houston Lake Tahoe Los Angeles
February 12, 2016
BOOTH CREEK PARK
1309 ELKHORN DRIVE. VAIL, COLORADO. 81657
970.479.2158
MECHANICAL COVER
SHEET
M1.0
PEC APPROVED
3/14/2016 12:00:00 AM