HomeMy WebLinkAboutPEC160009_M1.0_1465853400.pdfSHOCK ABSORBER STRAINER W/ BLOW-OFF VALVE SAFETY RELIEF VALVE PRESSURE GAUGE W/ PIG TAIL & COCK THERMOMETER PRESSURE - TEMP. TAP AIR VENT PIPE ANCHOR FLEXIBLE CONNECTOR PIPE EXPANSION JOINT PIPE UNION DOUBLE CHECK BACKFLOW PREVENTER TEMPERATURE CONTROL VALVE (2-WAY) FLOW BALANCING VALVE GATE OR GLOBE VALVE IN RISER FLOW CONTROL VALVE BALL VALVE PLUG OR BALANCING VALVE CHECK VALVE GLOBE VALVE BUTTERFLY VALVE TEMPERATURE CONTROL VALVE (3-WAY) SOLENOID VALVE 90° ELBOW UP TEE UP TEE DOWN SHUT OFF (BALL, GATE, BUTTERFLY) PIPING SYMBOLS 90° ELBOW DN S HOSE BIBB WALL HYDRANT TEMPERATURE CONTROLLER OR SENSOR FIXTURE CONNECTION SCHEDULE HW CW WASTE VENT : 1. SIZES SHOWN ARE MINIMUM PIPE SIZES TO A SINGLE FIXTURE. LARGER SIZES MAY BE INDICATED ON PLANS WHERE REQUIRED. 2. MINIMUM DOMESTIC PIPE SIZE TO (2) OR MORE FIXTURES IS 3/4". 3. RE: MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR INDIRECT WASTE SIZES. 4. WASTE AND VENT SIZES SHOWN ABOVE APPLY TO INDIVIDUAL VENTING ONLY. WHERE ALLOWED, INDIVIDUAL VENT CONNECTIONS MAY BE OMITTED OR SIZES MAY VARY WHEN CIRCUIT VENTS, COMMON VENTS, WASTE STACK VENTS, WET VENTS, OR COMBINATION DRAIN AND VENT SYSTEMS ARE USED. PRIOR APPROVAL FROM THE ENGINEER IS REQUIRED TO USE THESE ALTERNATIVE VENTING METHODS. 5. PROVIDE TRAP PRIMER FOR ALL FLOOR DRAINS AND FLOOR SINKS NOT LOCATED IN FOOD SERVICE AREAS. 6. MINIMUM SIZE FOR WASTE AND VENT PIPING BENEATH SLAB IS 2". 7. ALL FIXTURES LISTED ARE NOT NECESSARILY USED ON THIS PROJECT. 8. REFER TO APPLIANCE SCHEDULES (BY OTHERS) FOR ADDITIONAL PLUMBING FIXTURE CONNECTIONS SUCH AS INST-HOTS, COFFEE MAKERS, AND GARBAGE DISPOSALS. 9. PROVIDE ICE MAKER BOX ROUGH IN W/ 1/2"CW CONNECTION FOR ALL REFRIGERATOR LOCATIONS. ABBREV. DRINKING FOUNTAIN / E.W.C. DF - 1/2" 1-1/2" 1-1/2" FD FLOOR DRAIN - - 2" 1-1/2" FS FLOOR SINK - - 3" 2" HOSE BIB HB - - -3/4" HAND SINK HS 1-1/2" 1-1/2" 1/2" 1/2" LAVATORY LAV 1/2" 1-1/2" 1-1/2" 1/2" MOP SERVICE BASIN MSB 3/4" 3" 2" 3/4" SERVICE SINK SS 3" 2" 1/2" 1/2" URINAL (BLOWOUT) UR 1" 2" 1-1/2" - URINAL (WASHDOWN) UR UR URINAL (WATERLESS) 3/4" 2" 1-1/2" - 2" 1-1/2" - - WATER CLOSET (FLUSH VALVE) WC WATER CLOSET (FLUSH TANK) WCT - 1" 4" 2" - 1/2" 4" 2" EQUIPMENT ABBREVIATIONS AIR HANDLING UNIT AHU AIR SEPARATOR AS BOILER (HOT WATER) B BASE BOARD BB BUFFER TANK BT CONSTANT VOLUME BOX CV DISHWASHER EXHAUST FAN DEF ELECTRIC BASEBOARD HEATER EBH FURNACE F FAN COIL FC FAN POWERED BOX FP GLYCOL FEEDER GF HUMIDIFIER HC HEATING COIL HP HEAT PUMP HX HEAT EXCHANGER KITCHEN EXHAUST FAN KEF MAKE-UP AIR UNIT MAU MOTOR CONTROL CENTER MCC MIXING VALVE MV PUMP P RETURN (OR RELIEF) AIR FAN RF RADIANT ZONE RZ SNOWMELT AREA SA SUMP BASIN SB SUPPLY FAN SF STORAGE TANK ST THERMOSTATIC MIXING VALVE TMV UNIT HEATER UH VARIABLE VOLUME BOX VV WATER HEATER WH H CHILLER CH COILING COIL CC CIRC PUMP CP CABINET UNIT HEATER CUH COOLING TOWER CT DUCT COIL DC ELECTRIC WATER HEATER EWH EVAPORATIVE COOLING UNIT ECU ENERGY RECOVERY UNIT ERU EXHAUST FAN EF EXPANSION TANK ET VARIABLE VOLUME BOX W/ REHEAT VR REFERENCE SAMPLE FFI = FOR FURTHER INFORMATION FCT = FOR CONTINUATION RE: B/M400 FFI REFER TO: DRAWING NUMBER OR DIAGRAM LETTER SHEET NUMBER PLAN ABBREVIATIONS ABOVE FINISHED FLOOR AIR ADMITTANCE VALVE ABOVE FINISHED GRADE AUTOMATIC BUILDING AAV AFF AFG AUTO BLDG BETWEEN COMMON (OR CLOSED) CONTROLS CONTRACTOR CONTINUATION DESIGN BUILD B/N C CC CDBBC CUBIC FEET PER MINUTE (AIR FLOW RATE) CEILING (OR COOLING) CONCRETE CONDENSATE CONNECT (OR CONNECTION) CONTRACTOR CFM CLG CONC COND CONN CONTR'R CLEANOUT TO GRADE COTG DOMESTIC HOT WATER RECIRC DWR ENTERING AIR TEMPERATURE ELECTRICAL CONTRACTOR ENTERING WATER TEMPERATURE EAT EC EWT GENERAL CONTRACTOR GC GALLONS PER MINUTE (WATER FLOW RATE) GPM HOT WATER IN LIEU OF HW ILO LEAVING AIR TEMPERATURE LEAVING WATER TEMPERATURE LAT LWT MECHANICAL CONTRACTOR MC MANUFACTURER NEW MFG (N) NORMALLY CLOSED NC NOT IN CONTRACT NORMALLY OPEN NIC NO ON CENTER OC REQUIRED REQ'D REQUIREMENTS REQ'MTS SQUARE FOOT (FEET) SF THROW-AWAY (TRANSFER AIR) TYPICAL TA TYP UNLESS NOTED OTHERWISE UNO WALL CLEANOUT WCO WITH REGARD TO WATER COOLED TRANSFER WRT W/C XFR DIAMETER Ø BY CONTRACTOR COLD WATER CW HOT WATER RECIRC HWC ABOVE ABV BELOW FINISHED GRADE BFG DOMESTIC WATER DOMESTIC HOT WATER DW DHW DOMESTIC HOT WATER RECIRC DHR FURNISHED BY OWNER FBO FLOOR CLEANOUT FCO FOR CONTINUATION FCT REFER TO: RE: WITH W/ CLEANOUT CO FFI FOR FURTHER INFORMATION WITHOUT W/O VENT THRU ROOF VTR NOTES 1. ALL SYMBOLS, ABBREVIATIONS, AND DESIGNATIONS ON LEGEND SHEET ARE NOT NECESSARILY USED ON THIS PROJECT. 2. THIS DRAWING SET CONSISTS OF DATA GENERATED, IN PART, BY OTHER PARTIES. NOT ALL SYMBOLOGIES AND NOTATION CONVENTIONS OCCURRING IN THIS DRAWING SET ARE NECESSARILY DEFINED ON THESE LEGENDS. CONSULT THE ENGINEER IN THE EVENT SYMBOLOGY OR NOTATION INTERPRETATION IS REQUIRED. PLAN SYMBOLS CONTROL PANEL/RADIANT MANIFOLD DIAGRAM CONTINUATION REFERENCE PLUMBING/HVAC RISER POINT OF NEW CONNECTION ACCESS PANEL SECTION CUT LETTER/SHEET SHOWN ON POINT OF DISCONNECTION - -- - P THERMOSTAT T H B W H TC FLOOR DRAIN FLOOR SINK HORIZONTAL CLEANOUT VERTICAL CLEANOUT PIPING DESIGNATIONS HEATING WATER SUPPLY (HIGH TEMP) HEATING WATER RETURN (HIGH TEMP) CHILLED WATER SUPPLY CHILLED WATER RETURN CONDENSER RETURN DOMESTIC WATER DOMESTIC HOT WATER DOMESTIC HOT WATER (TEMP. SHOWN) DHW RECIRCULATION FIRE LINE PRESSURIZED WASTE PLUMBING VENT PIPE WASTE PIPE HEATING WATER SUPPLY (LOW TEMP) HEATING WATER RETURN (LOW TEMP) GROUND WATER SUPPLY GROUND WATER RETURN HEATING WATER SUPPLY HEATING WATER RETURN DRAIN PIPE CLOSED CONDENSER SUPPLY CLOSED CONDENSER RETURN CONDENSER SUPPLY PLUMBING PIPING NON-SOFTENED DOMESTIC WATER CR CS CCR CCS CHR CHS HWR HWS HWR(LT) HWS(LT) HWR(HT) HWS(HT) D GWR GWS CW HW HWC NS 140° HW V W PW F SOLID DRAIN PIPE DS HYDRONIC PIPING SUMP PUMP SP MECHANICAL SYSTEMS LEGEND ABOVE SEA LEVEL PROJECT ALTITUDE 8400' PLUMBING FIXTURE SCHEDULE SYMBOL TYPE A.D.A. FINISH MANUFACTURER* & MODEL # FAUCET TRIM MFR.* & MODEL # ACCESSORIES REMARKS SINK YES VITREOUS CHINA KOHLER K-15198-F & K-2035-1 - - - TOILET YES VITREOUS CHINA KOHLER K-4405 & K-4670-CA SLOAN OPTIMA FLUSHOMETERS ROYAL 111-1.28 - - URINAL YES VITREOUS CHINA SLOAN WEUS-1000.1001-0.125 - - - MOP SINK NO STAINLESS STEEL ADVANCE TABCO 9-OP-20 ADVANCE TABCO K-240 - - FLOOR DRAIN NO BRASS ZURN FD2201 - - - FLOOR SINK NO STAINLESS STEEL ZURN Z1752 - - - WALL HYDRANT - - WOODFORD B67 - FREEZELESS WALL HYDRANT - - WOODFORD MB24 - - - MANUFACTURERS: FIXTURE: AMERICAN STANDARD, UNIVERSAL RUNDLE, FIAT STERN WILLIAMS FAUCET: SPEAKMAN, DELTA, AMERICAN STANDARD, CHICAGO DRAIN: JOSAM, WADE SMITH GENERAL NOTES: A: B: P1 P2 P3 P4 P5 P6 P7 P8 WATER HEATER SCHEDULE (ELECTRIC) MARK TYPE STORAGE CAPACITY (GAL.) RECOVER Y (GPH) WATER TEMP. RISE (°F) ELECTRICAL MANUFACTURER* & MODEL # ACCESSORIES REMARKS KW VOLT/ PH WH-1 TANKLESS 0 0 65 13 240/1 RHEEM RTE 13 - - MANUFACTURERS: * A.O. SMITH, RUUD OR STATE EQUIVALENT GENERAL NOTES: A: B: ELECTRIC BASEBOARD HEATER MARK TYPE RATED BTUH ELECTRICAL MANUFACTURER* & MODEL # ACCESSORIES REMARKS BB-1 HEAVY- DUTY ELECTRIC 4.2 500 120/1 BERKO OBD500 THERMOSTAT, INTEGRAL DISCONNECT 28" LENGTH MANUFACTURERS: * QMARK, MARKEL, MARLEY, OR RUNTAL EQUIVALENT GENERAL NOTES: A: 1. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS IN FIELD PRIOR TO COMMENCEMENT OF WORK. REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. 2. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT, OWNER, AND ENGINEER. 3. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PERFORM HIS/HER WORK IN CONFORMANCE WITH ALL APPLICABLE CODES, ORDINANCES AND LIFE SAFETY FEATURES AS REQUIRED BY LOCAL, STATE, OR NATIONAL AUTHORITIES. THE CONTRACTOR SHALL VERIFY WITH THE ARCHITECT IF MODIFICATION OF HIS/HER WORK IS REQUIRED FOR COMPLIANCE. 4. ALL WORK OF ALL TRADES MUST BE IN STRICT COMPLIANCE, OR EXCEED THE MINIMUM MATERIAL AND METHOD REQUIREMENTS OF THE 2009 VERSION OF THE INTERNATIONAL BUILDING, MECHANICAL, PLUMBING, FUEL GAS, AND ENERGY CONSERVATION CODES AND THE 2014 NATIONAL ELECTRICAL CODE, ALL LOCAL ORDINANCES AND AMENDMENTS AND MANUFACTURER'S INSTALLATION RECOMMENDATIONS. IF A CONFLICT BETWEEN THOSE PUBLICATIONS EXISTS, THE MOST STRINGENT REQUIREMENT SHALL APPLY. 5. SYSTEMS SHALL BE COMPLETE, OPERABLE, AND READY FOR CONTINUOUS OPERATION PRIOR TO ACCEPTANCE BY THE OWNER. 6. SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. PERFORM AT A MINIMUM ALL CODE REQUIRED TESTS OR SYSTEMS. IF TESTS OF WORK ARE DEFECTIVE, CONTRACTOR SHALL MAKE CORRECTIONS NECESSARY AT NO ADDITIONAL COST TO OWNER. 7. ALL MATERIALS AND/OR EQUIPMENT SHALL BE HANDLED AND INSTALLED AS PER MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS. 8. ALL FLOOR DRAINS AND FLOOR SINKS CONNECTED TO THE SEWER SYSTEM SHALL BE EQUIPPED WITH TRAP PRIMERS. PROVIDE TRAP PRIMERS WITH BACKFLOW PREVENTERS AND CONNECT TO THE NEAREST COLD WATER PIPING ADJACENT TO A FLUSHING FIXTURE. PROVIDE ELECTRONIC TRAP PRIMERS FOR ANY AREAS WHERE THE NEAREST ADJACENT FLUSHING FIXTURES ARE NOT WITHIN A REASONABLE DISTANCE OR STRUCTURAL OBSTRUCTIONS PREVENT GRAVITY SLOPING OF TRAP PRIMER LINES. ADDED COST OF ELECTRIC POWER FOR ELECTRONIC TRAP PRIMERS SHALL BE BORNE BY PLUMBING CONTRACTOR. INSTALL ALL TRAP PRIMER VALVES AND ASSOCIATED SYSTEMS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 9. COORDINATE ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL, AND LANDSCAPE DRAWINGS PRIOR TO INSTALLATION. 10. CAREFULLY VERIFY ELECTRICAL SERVICE VOLTAGE AND PHASE AVAILABLE. 11. MOUNT ALL STATS AT 48” AFF IN “ACCESSIBLE” AREAS, 4'6” AFF IN OTHER AREAS, UNLESS NOTED OTHERWISE. COORDINATE LOCATION WITH WALL FINISH, AND TO AVOID CASEWORK, FURNITURE, DOOR SWINGS, HEAT SOURCES, AND EXTERIOR WALLS. NOTIFY THE DESIGN TEAM CONSTRUCTION ADMINISTRATOR OF ANY CONFLICTS PRIOR TO BEGINNING THERMOSTAT INSTALLATION. 12. REFER TO PLUMBING FIXTURE CONNECTIONS SCHEDULE FOR PIPE SIZES TO INDIVIDUAL PLUMBING FIXTURES. GENERAL NOTES: C SHEET NUMBER PROJECT NUMBER: 1 5431 2 3 4 5 6 7 A B C D E C O P Y R I G H T D E S I G N W O R K S H O P, I N C. F 8 9 1 2 3 4 5 6 7 8 9 100% DESIGN DEVELOPMENT DOCUMENTS COPYRIGHT 2016 B ANZE G EAUDIN (970) 949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 Vail: Denver: Fort Collins: Albuquerque: Jackson: www.bgce.com DESIGN DATE # DESCRIPTION ISSUE DATE: REVIEWED: DRAWN: WORKSHOP REVISIONS REDEVELOPMENT 2900 MANNS RANCH ROAD VAIL, COLORADO W W W . D E S I G N W O R K S H O P . C O M Landscape Architecture  Land Planning Urban Design  Tourism Planning Facsimile (970) 920-1387 (970) 925-8354 Aspen, CO 81611 120 E. Main St. Asheville  Aspen  Austin  Beijing  Chicago  Denver  Dubai  Houston  Lake Tahoe  Los Angeles February 12, 2016 BOOTH CREEK PARK 1309 ELKHORN DRIVE. VAIL, COLORADO. 81657 970.479.2158 MECHANICAL COVER SHEET M1.0 PEC APPROVED 3/14/2016 12:00:00 AM