HomeMy WebLinkAboutPEC17-0026_A3.0_1502996340.pdfT.O. EXISTING FIN FLR
EL. 8190.0' (8190'-0")
A3.0
1
SCALE: 1/4" = 1'-0"
SOUTH ELEVATION
T.O. EXISTING WALL
EL. 8203.6' (8303'-7 1/4")
EXISTING PLATE MTL GUARDRAIL
w/ROUND MTL TOP RAIL
EXISTING BUILDING
NEW METAL ROOF (w/HEAT TAPE) TO
MATCH ROOF AT INFORMATION CENTER
NEW TIMBER BEAM AND COLUMN
TO MATCH EXISTING
INFORMATION CENTER
FASCIA TO MATCH EXISTING
EXIST
WINDOW
EXIST
WINDOW
EXIST
WINDOW
NEW
DOOR
NEW
DOOR
NEW PLATE METAL RAIL
w/ROUND METAL TOP RAIL -
SIMILAR TO EXISTING
NEW BOULDER SITE WALLS (4'
MAX HEIGHT) RE: SITE PLAN
NEW EXTERIOR DECK w/
CONCRETE DECK SURFACE
w/SNOWMELT AND STEEL
STRUCTURE
EXISTING BOULDER SITE
WALLS w/NEW PLANTING AT
BENCH BETWEEN WALLS
RE: SITE PLAN
EXISTING CONCRETE STEPS
AND LOW WALL
MTL GUTTER w/HEAT TAPE
MTL SNOW FENCE
METAL SCREENING @ BEAM
LINE TO RESTRICT ACCESS
TO AREA UNDER DECK
METAL SCREENING @ BEAM
LINE TO RESTRICT ACCESS
TO AREA UNDER DECK
TRIPLE HEIGHT SNOW FENCE FOR
ROOF ACCESS DETERRENT
A3.0
2
SCALE: 1/4" = 1'-0"
EAST ELEVATION
T.O. EXISTING FIN FLR
EL. 8190.0' (8190'-0")
T.O. EXISTING FIN WALL
EL. 8203.6' (8303'-7 1/4")
EXISTING PLATE MTL GUARDRAIL
w/ROUND MTL TOP RAIL
EXISTING BUILDING
EXISTING ENTRY TO LEVEL THREE
OF PARKING STRUCTURE AND LA
CANTINA
NEW METAL ROOF TO MATCH
ROOF AT INFORMATION CENTER
NEW TIMBER BEAM AND COLUMN
TO MATCH EXISTING
INFORMATION CENTER
NEW PLATE METAL RAIL
w/ROUND METAL TOP RAIL -
SIMILAR TO EXISTING
NEW EXTERIOR DECK w/
CONCRETE DECK SURFACE
w/SNOWMETL AND STEEL
STRUCTURE
EXISTING BOULDER SITE WALLS TO REMAIN
RE: SITE PLAN (1/A1.0) & SECTION (3/A3.0)
EXISTING CONCRETE STEPS
AND LOW WALL
EXTENT OF EXISTING STAIR
RAIL - NOT SHOWN FOR
CLARITY
MTL SNOW FENCE
MTL GUTTER w/HEAT TAPE
HEAT TAPE @ ROOF
METAL SCREENING @ BEAM
LINE TO RESTRICT ACCESS
TO AREA UNDER DECK
TRIPLE HEIGHT SNOW FENCE FOR
ROOF ACCESS DETERRENT
STRUCTURAL T'S
STRUCTURAL T'S
STEEL CHANNEL
CONCRETE DECK
(w/SNOWMELT) SLOPED
TO CENTER DRAINS
w/HEAT TAPE
STEEL LEDGER
STEEL SUPPORT BEAM
ON DRILLED PIER
PIER AND CONCRETE CAP/BASE/COLUMN
TBD TO SUPPORT BEAM ABOVE
EXISTING BOULDER
RETAINING WALLS
TO REMAIN
METAL RAILING
SIMILAR TO EXISTING
SCALE: 1/4" = 1'-0"
SECTION
T.O. EXISTING FIN FLR
EL. 8190.0' (8190'-0")
T.O. EXISTING WALL
EL. 8203.6' (8203'-7 1/4")
EXISTING GRADE TO
REMAIN
NEW LANDSCAPING
PROPOSED GRADE TO
SLOPE 5% MIN AWAY
FROM BUILDING
EXISTING GRADE
3
A3.0
METAL SCREENING @ BEAM
LINE TO RESTRICT ACCESS TO
AREA UNDER DECK
MTL SNOW FENCE
MTL GUTTER
w/HEAT TAPE
HEAT TAPE @ ROOF TRIPLE HEIGHT SNOW FENCE FOR
ROOF ACCESS DETERRENT
0' 1' 2' 4' 8'
A3.0
PROPOSED ELEVATIONS & SECTION
LACANTINADECK
LEVELTHREE,
VAILTRANSPORTATIONCENTER
241SOUTHFRONTAGEROAD,
VAIL,
COLORADO
EAGLECOUNTYACCT#:R046881
The addition of snow fence does not stop someone from being able to get on the roof and in someways, it makes the condition worse. Please provide a positive means of stopping roof access.
PEC
APPROVED
7/24/2017 12:00:00 AM