Loading...
HomeMy WebLinkAboutA17-0041_Pages from Lodge Twr-Unit 787 Submittal-2081-9274_1503673920.pdfFeatures Rechargeable, sealed lead-acid batteries:  Lead-calcium grid structure with immobilized electrolyte in absorbent separator  Low maintenance with no need to add water  Low self-discharge characteristics  One-piece, high impact polystyrene cell cover with high reliability dual seal construction  UL 924 recognized pressure relief valves Available in a variety of capacities:  Batteries for internal mounting range from 6.2 Ah up to 50 Ah, depending on control panel cabinet size  Larger batteries, up to 110 Ah, mount in external battery cabinets with models available with internal chargers Battery cabinets with chargers:  Battery cabinets with charger communicate with their connected fire alarm control panel and are available for 4100ES/4010ES/4100U Series and 4010 Series panels Description Simplex® rechargeable sealed-lead acid batteries provide reliable and repeatable discharge and recharge characteristics for use in fire alarm and other systems applications. They are designed with immobilized electrolyte in an absorbent separator, allowing them to provide rated capacity on the first cycle. Because of their sealed construction, packaging is allowed within the system electronics enclosure (see illustration on page 2). When this is applicable, the quantity of system cabinets and the battery wiring distances are both minimized. Where required, external battery cabinets can be close-nippled to the control panel to house larger batteries with battery chargers available in some battery cabinet sizes. Battery Details Charging. These batteries are intended to be used with compatible Simplex battery chargers. Series Connections. These batteries are required to be connected in series to produce 24 V system voltage. Battery sets must be of identical voltage, model number, appearance, and approximately the same date of manufacture for proper operation. Testing. Battery capacity testing is recommended to be performed by using a sealed lead-acid battery tester designed to withdraw a minimum of battery charge. The preferred tester applies a variety of amplitude and duration controlled test pulses that compares terminal voltage against those predicted for the specific battery size. (Testing is available through your local Simplex product supplier.) can be Cabinets Available for shipped via not shipped Accessories Applications Charger Vail Fire & Emergency Services 08/25/17 Actual appearance will vary with battery size. 2 S2081-0006-22 10/2016 Nominal Voltage Rating 12 Volts per battery Discharge Rating 20 Hour Rate Typical Charge/Discharge Cycles 100 to 150 Preferred Charge Temperature Range 60° F to 90° F (15.6°C to 32.2° C) Quick connect or post type terminal (type varies with battery size) Inner cover Absorbent separator used to immobilize electrolyte Lead-calcium grids Cell group Cell case (high impact polystyrene) Sealed outer cover Vent hole Potting material, black for negative, red for positive (polarity is also clearly marked with + and -) Pressure relief valve Semi-permeable membrane separator Battery Model Capacity @ 20 Hour Discharge Rate Width* Depth*Height with Terminals Approximate Weight* 2081-9272 6.2 Ah 6-1/8” (156 mm) 2-5/8” (67 mm) 4” (102 mm) 5.75 lbs (2.6 kg) 2081-9274 10 Ah 6” (153 mm) 4-1/16” (103 mm) 4” (102 mm) 9.2 lbs (4.2 kg) 2081-9288 12.7 Ah 6” (153 mm) 4” (102 mm) 4” (102 mm) 9 lbs (4.1 kg) 2081-9275 18 Ah 7-1/4” (184 mm) 3-3/8” (86 mm) 6-5/8” (168 mm) 14.3 lbs (6.5 kg) 2081-9287 25 Ah 6-5/8” (168 mm) 5” (127 mm) 7” (178 mm) 19.4 lbs (8.8 kg) 2081-9271 (rectangular case, typically for service) 33 Ah 12-1/2” (318 mm) 3-3/8” (86 mm) 7-1/16” (179 mm) 26.6 lbs (12.1 kg) 2081-9276 (“square” case, use for new) 33 Ah 7-3/4” (197 mm) 5-1/4” (133 mm) 6-3/4” (171 mm) 26.5 lbs (12 kg) 2081-9296 50 Ah 9” (229 mm) 5-1/2” (140 mm) 8-7/8” (225 mm) 41.8 lbs (19 kg) 2081-9279 110 Ah 11-3/16” (284 mm) 10-1/2” (267 mm) 9” (230 mm) 82 Lbs (37 kg) * Dimensions and weight are per battery and are for reference only. Exact size may vary. Refer to the tables on page 3 for mounting compatibility. These batteries are 12 V each and series connected for 24 V system use. NOTE: When wired in series for 24 V output, these batteries are to be of identical voltage, appearance, model number, and approximately the same date of manufacture. Battery Construction Reference Battery Size Specifications General Battery Specifications Vail Fire & Emergency Services 08/25/17 3 S2081-0006-22 10/2016 Battery Cabinets without Chargers (connects to charger in panel) Cabinet Panel Compatibility Battery 2081-9275 18 Ah* 2081-9287 25 Ah 2081-9271 Rectangular 33 Ah 2081-9276 Square 33 Ah 2081-9296 50 Ah 2081-9279 110 Ah 2081-9280 4100ES, 4010ES, 4100U, and 4100+NA NA NA NA NA 2081-9281 2081-9282 multiple NA 4009-9801 multiple ** NA NA NA NA 4009-9802 multiple NA NA NA NA Battery Cabinets with Chargers Cabinet Panel Compatibility 2081-9275 18 Ah* 2081-9287 25 Ah 2081-9271 Rectangular 33 Ah 2081-9276 Square 33 Ah 2081-9296 50 Ah 2081-9279 110 Ah 4081-9301 4081-9302 4004R and 4010 NA 4081-9306 4081-9308 4100ES, 4010ES, and 4100U NA NA NA NA * Batteries smaller than those listed are normally mounted in the product cabinet ** 25 Ah capacity was effective as of 7/2005. = Can be placed in the respective equipment cabinet NA = Not applicable/not compatible NOTE: Refer to individual fire alarm control panel product data sheets for additional battery application information Battery Model Capacity Simplex Control Panel Model Series (see legend and notes below) 4003EC 4004R 4007ES & 4005 4006 & 4008 4009 (all models) 4010 4010ES4100ES/ 4100U 4100 & 4120 (2, 4 or 6-Unit) 2081-9272 6.2 Ah 2081-9274 10 Ah 2081-9288 12.7 Ah 2081-9275 18 Ah Ext Note 3 Ext Ext Note 2 2081-9287 25 Ah Ext Note 3 Ext Ext NA 2081-9271 rectangular 33 Ah Ext Note 3 Ext NA NA Note 3 Ext 2081-9276 “square”33 Ah Ext Note 3 NA NA NA Note 3 2081-9296 50 Ah NA Note 3 NA NA NA Note 3 Note 6 2 or 3 bay Ext 2081-9279 110 Ah Requires external battery cabinet, compatible with 4100ES, 4010ES, 4100, and 4120 Series only = Can be placed in the respective equipment cabinet Ext = External battery cabinet is required, refer to selection chart on page 4 NA = Not applicable/not compatible NOTES: 1. These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers listed above. Contact your local Simplex product supplier for proper battery selection per system requirements. 2. 4010 Cabinets will accommodate 2081-9275, 18 Ah batteries, but will not allow bottom entry conduit. 3. Use 4081 series companion cabinet and charger, refer to page 4. 4. Some control panel models are listed for battery replacement reference only. 5. For 2 bay international applications only, 50 Ah batteries will fit in the cabinet. Battery Compatibility for Fire Alarm Control Panel Mounting External Battery Cabinet Compatibility Reference Vail Fire & Emergency Services 08/25/17 Battery Cabinets Without Chargers; Shallow Design with Front Door Model Color Listings Description Dimensions 2081-9281 Beige UL and FM 2-Unit, 4100 style cabinet without charger; with locking solid door and battery shelf, primarily for use with 50 Ah batteries 25-3/4” W x 20-3/4” H x 6-3/4” D (654 mm x 527 mm x 171 mm)2081-9282 Red 4003-9860 Beige Multiple Intended for use with 4003EC systems, for up to 33 Ah batteries (refer to 4003EC data sheet S4003-0002) 9-1/2” H x 24” W x 9” D (241 mm x 610 mm x 229 mm) 4009-9801* Beige UL and FM For up to 25 Ah batteries* External battery cabinet without charger, with locking solid door and battery harness; for close-nippled mounting to fire alarm control panel cabinet 16-1/4” W x 13-1/2” H x 5-3/4” D (413 mm x 343 mm x 146 mm)* 4009-9802 Beige UL For up to 33 Ah batteries 25-3/4” W x 20-3/4” H x 4-1/8” D (654 mm x 527 mm x 105 mm) * Depth increased for 25 Ah batteries effective 7/2005. Chargers for use with 4010 Fire Alarm Control Panels and 4004R Suppression Release Systems (refer to data sheet S4081-0001) Model Color Input Voltage Description Dimensions 4081-9301 Beige 120 VAC Battery cabinet with charger for the 4010 and 4004R fire alarm control panel; for up to 50 Ah batteries; with front door Listings include: UL, ULC, FM, CSFM, and MEA (NYC), see data sheet for details 22-1/2” W x16-3/4” H x 8-3/8” D (572 mm x 425 mm x 213 mm) 4081-9302 Red Battery Cabinet Without Charger for 110 Ah Batteries; for use with compatible panel mounted chargers (refer to data sheet S2081-0012) Model & Listings Color Cabinet DescriptionCompatible Chargers Charger Description Dimensions 2081-9280 Listings include: UL and CSFM Red Battery cabinet for 2081-9279, 110 Ah batteries; includes 80 A battery fuse, terminals and battery connection cables; see data sheet for details 4010-9xxx Series 4010ES Main System Supply (MSS) 26-1/2” W x 12” H x 12” D (673 mm x 305 mm x 305 mm) 4100-9xxx Series 4100ES/4100U System Power Supplies (SPS) 4100-5111 4100-5112 4100-5113 4100ES/4100U Additional SPS 4100-5125 4100-5126 4100-5127 4100ES/4100U Remote Power Supply (RPS) 4100-5120 4100-5121 4100-5122 4100ES/4100U TrueAlert Addressable Power Supply (TPS) 4100-0104 4100-0114 4100-0124 4100 Legacy power supplies 4100ES/4010ES/4100U Compatible Battery Cabinet With Charger for 110 Ah Batteries (for ULC listed systems and for other applications unable to use panel mounted power supply charger; refer to data sheet S4081-0002) Model Color Input Voltage Description Dimensions 4081-9306 Red 120 VAC Battery cabinet with charger for up to 110 Ah batteries; NOTE: Required for ULC listed charging of 110 Ah batteries; Listings include: UL, ULC, FM, CSFM, and MEA (NYC), see data sheet for details 27-7/8” W x 13-1/2” H x 14-5/8” D (708 mm x 343 mm x 371 mm) 4081-9308 Red 220/230/240 VAC, multi-tapped 4100-9837 Green LED Power-on Indicator Kit, required for ULC listing, mounts above access panel using knockout provided Tyco Fire Protection Products • Westminster, MA • 01441-0001 • USA S2081-0006-22 10/2016 www.simplex-fire.com © 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. External Battery Cabinet Specification Reference Vail Fire & Emergency Services 08/25/17