Loading...
HomeMy WebLinkAboutB17-0320_1701_Berger_Building-Permit-Revisions_08-22-17_1503686040.pdfNOTES: 1. DETAILS COPIED FROM ORIGINAL CONSTRUCTION DOCUMENTS BY OTHERS DATED 12/15/99 FOR ORIGINAL BUILDING PERMIT APPLICATION & CONSTRUCTION 2. SHOWN FOR INFORMATION ONLY 3. GC TO VERIFY EXISTING CONDITIONS AS MATCH AND/OR REPAIR AS REQUIRED 1 A 2 3 4 B EXISTING DOOR TO BE RELOCATED NOTE: GC TO MAINTAIN FIRE SEPARATION AT EXISTING PARTY WALL EXISTING BUILDING NO CHANGES ADJACENT UNIT NOT IN CONTRACT ADJACENT UNIT NOT IN CONTRACT ADJACENT UNIT NOT IN CONTRACT (2): 2x4 (2): 2x4 (2): 2x10 HEADER EXISITNG WINDOW TO BE REPLACED; USE EXISTING R.O., HEADER, FLASHING & WEATHER PROOFING; REPAIR AS REQUIRED TO MATCH EXISTING EXISTING WOOD SIDING (UNCHANGED) EXISTING SHEATHING (UNCHANGED) EXISTING INSULATION & VAPOR BARRIER (UNCHANGED) EXISTING INTERIOR WALL BOARD EXISTING HEADER AND BLOCKING (UNCHANGED) EXISTING METAL FLASHING (UNCHANGED) EXISTING WOOD WINDOW TRIM (UNCHANGED) NEW ALUMINUM CLAD WOOD WINDOW TO REPLACE EXISTING EXISTING SELF-ADHERING MEMBRANE FLASHING (UNCHANGED) NOTES: 1. ALL EXISTING WALL STRUCTURE, WEATHER PROOFING, AND INTERIOR AND EXTERIOR FINISHES TO REMAIN INTACT. 2. EXISTING INTERIOR AND EXTERIOR TRIM TO BE REMOVED AS NECESSARY TO FACILITATE EXISTING WINDOW REMOVAL, AND REPLACED WITH SAME OR EQUIVALENT MATERIALS. 3. ANY DAMAGED EXISTING BUILDING COMPONENTS TO BE REPLACED WITH LIKE MATERIALS TO SEAMLESSLY MATCH EXISTING IN PERFORMANCE AND VISUAL CRITERIA. APPLY EXPANDING FOAM SEALANT AT VOIDS BETWEEN WINDOW FRAME AND R.O. AT ALL SIDES CONTINUOUS BEAD OF SEALANT BETWEEN WINDOW FRAME AND TRIM AT ALL EDGES EXISTING STUCCO SIDING (UNCHANGED) EXISTING SHEATHING (UNCHANGED) EXISTING INSULATION & VAPOR BARRIER (UNCHANGED) EXISTING INTERIOR WALL BOARD EXISTING BLOCKING (UNCHANGED) EXISTING METAL FLASHING (UNCHANGED) EXISTING STUCCO WINDOW TRIM (UNCHANGED) NEW ALUMINUM CLAD WOOD WINDOW TO REPLACE EXISTING EXISTING SELF-ADHERING MEMBRANE FLASHING (UNCHANGED) NOTES: 1. ALL EXISTING WALL STRUCTURE, WEATHER PROOFING, AND INTERIOR AND EXTERIOR FINISHES TO REMAIN INTACT. 2. EXISTING INTERIOR AND EXTERIOR TRIM TO BE REMOVED AS NECESSARY TO FACILITATE EXISTING WINDOW REMOVAL, AND REPLACED WITH SAME OR EQUIVALENT MATERIALS. 3. ANY DAMAGED EXISTING BUILDING COMPONENTS TO BE REPLACED WITH LIKE MATERIALS TO SEAMLESSLY MATCH EXISTING IN PERFORMANCE AND VISUAL CRITERIA. APPLY EXPANDING FOAM SEALANT AT VOIDS BETWEEN WINDOW FRAME AND R.O. AT ALL SIDES CONTINUOUS BEAD OF SEALANT BETWEEN WINDOW FRAME AND TRIM AT ALL EDGES EXISTING INTERIOR WINDOW SILL & SKIRT TRIM TO BE REPLACED AS REQUIRED TO MATCH EXISTING Project Address 5166A Black Gore Drive Vail, CO 81657 Parcel Number: 2099-182-12-012 Subdivision: Gore Creek Subdivision, Block 1, Lot 4N Owner 5166A Black Gore, LLC c/o: Bruce Berger 2 Chittenden Lane Owings Mills, MD 21117-4105 Designer mpp design shop inc. Michael Pukas PO Box 288 (970) 390-4931 michael@mppdesignshop.com General Contractor BZ Construction Brian Zaikis (970) 904-5209 zaikis@comcast.net Structural Engineer Ewing Engineering, Inc. Albert Ewing PO Box 2526 Vail, CO 81658 (970) 471-0124 ewing-vail@comcast.net Land Surveyor Peak Land Consultants, Inc. Brent Biggs 1000 Lions Ridge Loop, Suite 1D Vail CO 81657 (970) 476-8644 brent@peakland.net Scale Project Number: Drawn by: Checked by: mpp design shop, inc. PO Box 288 95 Willowstone Place Gypsum, CO 81637 (970) 390-4931 michael@mppdesignshop .com As indicated A5.1 DETAILS 1701 mpp mpp Berger Residence 5166 A Black Gore Drive Vail, CO 81657 Parcel Number: 2099-182-12-012 Subdivision: Gore Creek Subdivision, Block 1, Lot 4N # Description Date 4 Building Permit 08/22/17 3" = 1'-0" 6 WINDOW HEAD DETAIL - EXISTING 3" = 1'-0" 5 WINDOW JAMB MULLED - EXISTING 3" = 1'-0" 4 WINDOW SILL DETAIL - EXISTING 1/4" = 1'-0" 1 LEVEL 1 FRAMING PLAN 3" = 1'-0" 3 WINDOW HEAD DETAIL 3" = 1'-0" 2 WINDOW SILL DETAIL 08/25/17