HomeMy WebLinkAboutB17-0320_A2.1_1503686040.pdfD D USBUSB USBUSB EXIS TING 11' - 7 3/4" V.I.F. EXISTING 12' - 11" V.I.F. EXISTING 11' - 1" V.I.F. EXISTING 4' - 2 5/8" V.I.F. EXIS TING 3' - 0" V.I.F. EXIS TING 7' - 7 3/4" V.I.F. 4' - 2 1/4" 4 3/4" 6' - 0 3/4" EXISTING DOOR TO BE RELOCATED; ALL DISTURBANCE TO BE REPAIRED TO MATCH EXISTING ADJACENT SURFACES EXISTING FIXED WINDOW TO BE REMOVED; PROVIDE NEW CASEMENT WINDOW; ALL DISTURBANCE TO BE REPAIRED AND REPLACED TO MATCH EXISTING ADJACENT SURFACES; NEW WINDOW TO MEET EGRESS REQUIREMENTS; G.C. TO FIELD VERIFY SIZE NOTE: GC TO MAINTAIN FIRE SEPARATION AT EXISTING PARTY WALL 1 A 2 3 4 5 B C D F 4' - 0" 2' - 0" EXISTING STAMPED CONCRETE DECK NO CHANGES EXISTING BUILDING NO CHANGES ADJACENT UNIT NOT IN CONTRACT E ADJACENT UNIT NOT IN CONTRACT ADJACENT UNIT NOT IN CONTRACT EXISTING FIXED WINDOW TO BE REMOVED; PROVIDE NEW CASEMENT WINDOW; ALL DISTURBANCE TO BE REPAIRED AND REPLACED TO MATCH EXISTING ADJACENT SURFACES; NEW WINDOW TO MEET EGRESS REQUIREMENTS; G.C. TO FIELD VERIFY SIZE NO CHANGES TO EXSTING BUILDING NO CHANGES TO EXSTING BUILDING EXISTING RECESSED LIGHTING FIXTURES; (1) TO BE REMOVED, (1) TO BE RELOCATED EXISTING CEILING FAN TO BE REMOVED; INSTALL NEW SURFACE MOUNTED LIGHTING FIXTURE PROVIDED BY OWNER EXISTING RECESSED LIGHTING FIXTURES TO REMAIN RELOCATE (1) EXISTING RECESSED LIGHTING FIXTURES NOTE: GC TO MAINTAIN FIRE SEPARATION AT EXISTING PARTY WALL 1 A 2 3 4 5 B C D F 1' - 6" (2) DUPLEX OUTLET + DUAL USB CHARGING PORTS (2) DUPLEX OUTLET + DUAL USB CHARGING PORTS EXISTING BUILDING NO CHANGES ADJACENT UNIT NOT IN CONTRACT A2.1 4 BEDROOM NORTH WALL 5 BEDROOM SOUTH WALL 1' - 0" 1' - 6" 1' - 0" (2) WALL MOUNTED READING LIGHTS; PROVIDED BY OWNER (2) WALL MOUNTED READING LIGHTS; PROVIDED BY OWNER E EXISTING CEILING FAN FROM BEDROOM TO BE MOUNTED AT EXISTING CEILGIN JUNCITON BOX; GC TO VERIFY PROPER JUNCTION BOX TO SUPPORT CEILING FAN, VERIFY SWITCH LOCATION AND PROVIDE NEW ADJUSTABLE-SPEED FAN SWITCH AS REQUIRED NEW SURFACE MOUNTED LED STRIP LIGHTS AT EACH CLOSET; PROVIDED BY OWNER NEW JAMB MOUNTED SWITCH AT EACH LIGHT/DOOR Level 1 100' - 0" Level 2 110' - 0" 1 2 3 4 2' - 11" 6' - 9" 1' - 0" 1' - 6" Level 1 100' - 0" Level 2 110' - 0" 1 2 3 4 2' - 11" 1' - 6" 1' - 0" 6' - 9" Scale Project Number: Drawn by: Checked by: mpp design shop, inc. PO Box 288 95 Willowstone Place Gypsum, CO 81637 (970) 390-4931 michael@mppdesignshop .com As indicated A2.1 PLANS, ELEVATIONS, RCP/ELECTRICAL 1701 mpp mpp Berger Residence 5166 A Black Gore Drive Vail, CO 81657 Parcel Number: 2099-182-12-012 Subdivision: Gore Creek Subdivision, Block 1, Lot 4N 1/4" = 1'-0" 1 LEVEL 1 PLAN # Description Date 1 DRB Submission 08/27/17 2 Building Permit 08/14/17 1/4" = 1'-0" 3 EAST ELEVATION - EXISTING 1/4" = 1'-0" 2 LEVEL 1 RCP 1/2" = 1'-0" 4 BEDROOM NORTH WALL 1/2" = 1'-0" 5 BEDROOM SOUTH WALL 08/25/17