HomeMy WebLinkAboutB17-0320_A2.1_1503686040.pdfD
D
USBUSB
USBUSB
EXIS
TING
11' - 7 3/4"
V.I.F.
EXISTING
12' - 11" V.I.F.
EXISTING
11' - 1" V.I.F.
EXISTING
4' - 2 5/8" V.I.F. EXIS
TING
3' - 0" V.I.F.
EXIS
TING
7' - 7 3/4"
V.I.F. 4' - 2 1/4"
4 3/4" 6' - 0 3/4" EXISTING DOOR TO BE
RELOCATED; ALL DISTURBANCE
TO BE REPAIRED TO MATCH
EXISTING ADJACENT SURFACES
EXISTING FIXED WINDOW TO BE
REMOVED; PROVIDE NEW
CASEMENT WINDOW; ALL
DISTURBANCE TO BE REPAIRED
AND REPLACED TO MATCH
EXISTING ADJACENT SURFACES;
NEW WINDOW TO MEET EGRESS
REQUIREMENTS; G.C. TO FIELD
VERIFY SIZE
NOTE:
GC TO MAINTAIN FIRE
SEPARATION AT EXISTING
PARTY WALL
1
A
2 3 4 5
B
C
D
F
4' - 0"
2' - 0"
EXISTING STAMPED
CONCRETE DECK
NO CHANGES
EXISTING BUILDING
NO CHANGES
ADJACENT UNIT
NOT IN CONTRACT
E
ADJACENT
UNIT
NOT
IN CONTRACT
ADJACENT
UNIT
NOT IN CONTRACT
EXISTING FIXED WINDOW TO BE REMOVED;
PROVIDE NEW CASEMENT WINDOW; ALL
DISTURBANCE TO BE REPAIRED AND REPLACED
TO MATCH EXISTING ADJACENT SURFACES; NEW
WINDOW TO MEET EGRESS REQUIREMENTS; G.C.
TO FIELD VERIFY SIZE
NO CHANGES TO EXSTING BUILDING
NO CHANGES TO EXSTING BUILDING
EXISTING RECESSED LIGHTING
FIXTURES; (1) TO BE
REMOVED, (1) TO BE
RELOCATED
EXISTING CEILING FAN TO BE
REMOVED; INSTALL NEW
SURFACE MOUNTED LIGHTING
FIXTURE PROVIDED BY OWNER
EXISTING RECESSED LIGHTING
FIXTURES TO REMAIN
RELOCATE (1) EXISTING
RECESSED LIGHTING FIXTURES
NOTE:
GC TO MAINTAIN FIRE
SEPARATION AT EXISTING
PARTY WALL
1
A
2 3 4 5
B
C
D
F
1' - 6"
(2) DUPLEX OUTLET + DUAL
USB CHARGING PORTS
(2) DUPLEX OUTLET + DUAL
USB CHARGING PORTS
EXISTING BUILDING
NO CHANGES
ADJACENT UNIT
NOT IN CONTRACT
A2.1
4
BEDROOM
NORTH WALL
5 BEDROOM
SOUTH WALL
1' - 0"
1' - 6"
1' - 0" (2) WALL MOUNTED READING
LIGHTS; PROVIDED BY OWNER
(2) WALL MOUNTED READING
LIGHTS; PROVIDED BY OWNER
E
EXISTING CEILING FAN FROM BEDROOM TO
BE MOUNTED AT EXISTING CEILGIN JUNCITON
BOX; GC TO VERIFY PROPER JUNCTION
BOX TO SUPPORT CEILING FAN, VERIFY
SWITCH LOCATION AND PROVIDE NEW
ADJUSTABLE-SPEED FAN SWITCH AS
REQUIRED
NEW SURFACE MOUNTED LED
STRIP LIGHTS AT EACH CLOSET;
PROVIDED BY OWNER
NEW JAMB MOUNTED SWITCH AT
EACH LIGHT/DOOR
Level 1
100' - 0"
Level 2
110' - 0"
1
2 3 4 2' - 11"
6' - 9"
1' - 0"
1' - 6"
Level 1
100' - 0"
Level 2
110' - 0"
1 2 3 4 2' - 11"
1' - 6"
1' - 0"
6' - 9"
Scale
Project Number:
Drawn by:
Checked by:
mpp design shop, inc.
PO
Box
288
95 Willowstone
Place
Gypsum,
CO
81637
(970)
390-4931
michael@mppdesignshop
.com
As indicated
A2.1
PLANS, ELEVATIONS,
RCP/ELECTRICAL
1701
mpp
mpp
Berger Residence
5166 A Black Gore Drive
Vail, CO 81657
Parcel Number: 2099-182-12-012
Subdivision: Gore Creek Subdivision, Block
1, Lot 4N
1/4" = 1'-0" 1
LEVEL 1 PLAN
# Description Date
1 DRB Submission 08/27/17
2 Building Permit 08/14/17
1/4" = 1'-0"
3
EAST ELEVATION - EXISTING
1/4" = 1'-0"
2
LEVEL 1 RCP
1/2" = 1'-0"
4
BEDROOM NORTH WALL
1/2" = 1'-0" 5
BEDROOM SOUTH WALL
08/25/17