HomeMy WebLinkAboutDRB17-0371_A1.02 First Floor_1503691860.pdfMAIN FLOOR MODULES
1 2 3 4
5 6 7 8
THIRD FLOOR MODULES
RevID ChID Change Name Date
01 8/24/17
evoDOMUS LLC
3143 W 33rd Street
Cleveland, OH 44109
Phone : (216) 772-2603
Sheet Size:
24" x 36"
Sheet Number:
A1.02
Phase:
Date:
Project
Number:
STM Project
Name:
Sturm
Residence
Client:
First Floor
Drawing:
First Floor
Scale:
1/4" = 1'-0"
PERMIT SET
8/10/2017
Paul and Leisa Sturm
5044 Main Gore Drive S
Vail, Colorado 81657
Devepoler / Plan Preparer:
Lot 2 Vail Meadows Filing No. 1
RWS Architectural
Consulting
1361 Lakeland Ave.
Lakewood, OH 44107
Phone: (216) 401-3830
rwshearer@gmail.com
Robert W. Shearer, RA
Colorado
Registered
Architect
number:
ARC.00404908
License
Expires
10-31-2017
Architect:
S
ROBERT
W.
SHEARER
404908
R
T
A
T
E
O
F
C
O
L
O
R
A
D
O
E
G
I
S
TE
R
E
D
A
R
C
H
I
T
E
C
T
209.1 (TT/FX/FX)(t)
310.1
7'
3'
211.1
7'
3'
(TT/FX)(t)
15'-101/4" 15'-23/4"
27'-67/8" 5'-31/8" 9'-23/4"
40'-8"
61/8"
18'-73/4" 4'-23/4" 4'-21/4"
1'-11/4"
6'-0"
1'-10" 43/4"
8'-01/4"
6'-01/4"
2'-0"
8'-4"
1'-11/2"
3'-117/8" 4'-6"
6'-7"
1'-9"
3'-0"
3'-0"
7'-71/4" 5'-81/8"
4'-81/8" 4'-11/8" 61/8" 6'-65/8" 43/4" 2'-47/8" 43/4" 4'-71/2" 4'-3" 1'-41/8" 31/2"
6'-31/2"
61/8"
3'-0"
3'-0"
4'-91/4"
4"
8'-11 1/2"
PATCH DRYWALL AT
ALL MATING WALLS
(ENTIRE BUILDING)
BUILDING)
NON-MODULE
ROOF STRUCTURE
PROVIDE AND
INSTALL BUILT UP
FLAT ROOFING
SYSTEM. SEE
SPECS FOR MORE
INFORMATION.
INTERNAL DRAIN
FROM ROOF
PANEL 1F
BUILT-IN
MAKE-UP
VANITY
ELEVATOR
CAB 40"x54"
CLEAR INTERIOR
DRYWALL SHAFT - 3 SIDES;
3/4" PLYWOOD on RAIL SIDE
SOFFIT
SHOE
SHELVES
3' HIGH
BUILT-IN
CHEST OF DRAWERS
BUILT-IN
CLOSET SYSTEM
DN
DOWN
SPOUT
DOWN
SPOUT
CLEAR GL.
FOYER
201
STONE
Installed by:LC
A: 157 sq ft
H: 8.50'
STAIR
206
(LANDING) STONE
Installed by:LC
A: 37 sq ft
H: 8.50'
HALL
207
STONE
Installed by:LC
A: 43 sq ft
H: 8.50'
WC
208
STONE
Installed by:LC
A: 40 sq ft
H: 8.50'
MASTER BED
209
EWP-1
Installed by:LC
A: 223 sq ft
H: 8.50'
WIC
210
EWP-1
Installed by:LC
A: 65 sq ft
H: 8.50'
DECK
Thermory
A: 176 sq ft
MASTER BATH
211
STONE
Installed by:MC
A: 195 sq ft
H: 8.50'
202.1
(TT/FX/FX)(t)
211.1
(FX)(t)
209.3
(LS)(t)
6
5
3
4
eD
35.09.03 (TYP)
15'-101/4" 15'-23/4"
58'-113/4" 9'-35/8"
6'-0"
41/8" 1'-13/4"
41/8" 8'-5" 63/4"
8'-57/8" 9'-51/2"
4'-91/4"
8'-91/4" 41/8"
6'-87/8" 13'-33/8" 1'-113/8"
3'-6" 61/8"
8'-33/4" 43/4"
3'-6" 2'-0"
93/4"
NON-MODULE
ROOF AND
STRUCTURE
STEPS AND
RETAINING WALLS
BUILT-IN BENCH
6x6
GALVANIZED
STEEL POST
POWDER
COATED TO
MATCH METAL
CLADDING AT
BALCONY
UP 18R
UP 2R
DN 7R
SITE FRAMED,
EWP
CLAD
BENCH w/ STEPDN 6R
DN 4R
DRB
APPROVED
8/25/2017
12:00:00 AM