Loading...
HomeMy WebLinkAboutDRB17-0280 Solar Calculations.pdf ACTI ' F ENE r � SO itc SOLAR INSTALLATION INFORMATION1.0 et,51iginan Vendor: Active Energies Solar LLC DRB PO Box 7627 APPROVED 9/5/2017 12:00:00 Avon, CO 81620 AM (970-306-423 3/info@activeenergies.com) Site: Baggaley Residence 4352 Spruce Way#5 Vail, CO. 81657 Equipment: Panels: 14 LG320N1C-G4 solar panels @ 320watts Inverter: 14 SolarEdge P320 Optimizers+ 1 SolarEdge SE3800A-US inverter Mounting Equipment:Unirac racking system w/DPW easy feet mounting feet Monitoring: SolarEdge Remote Energy Monitoring System System Layout: Single Panel=5.38ft tall X 3.28ft wide Panel Arrangement: 2 rows of 3 and 2 rows of 4 with all panels oriented in the portrait position,mounted flush on the south facing roof 3'tire code setback •• - Holy Cross Meter • •••• ##$### Production meter, inverter,and back-feed disconnect e 1, • Holy Cross electric meter located on the northside of unit 3. Production meter to be located on the south side of unit 5. Inverter to be located adjacent to production meter. Minimum Designed Temperature: -40°F Maximum Ambient Design Temperature: 140°F All AC wiring to be completed by a Colorado licensed master electrician All DC wiring to be overseen by NABCEP certified installer Page 1 of 4 7/10/2017 PD.1313:07PA a7,SQl i 1020 1109101'229' P796.3t33330148sr q. y3.316.51C133, .4ctiN(eenarguasca ie .cert_ ACTI ENEr ' F P� SO itc CALCULATIONS oj icinot 4.48kW System Size (STC) DRB APPROVED 9/5/2017 12:00:00 Panels: 14 LG320N1C-G4 @ 320watts AM Inverter: 14 SolarEdge P320 Optimizers Inverter: SolarEdge SE3800A-US Inverter(1 string of 14 modules/optimizers) Array tilt angle: 26.57° Array azimuth: 220° (where 180°is south) Estimated annual power production: 4,612kWh Maximum PV System Voltage: 690.7 Voc=40.9V/module 40.9V x 1 module=40.9V Temperature correction factor 690.7(A) Temperature Coefficient (Voc) = -0.28%/°C (-65C° x (-.0028C°)) = .182% ((.182% x 40.9V)x 1 panels) +40.9V=48.3V Maximum PV Source Circuit(String) Current: 690.8 (A)(1) ISS= 10.05A 10.05A x 1.25 = 12.6A Maximum PV Output Circuit(Array) Current: 690.8 (A)(2) Max Inverter Input Circuit 13A Inverter Output Circuit Current: 690.8 (A)(3) 16A @ 240V Page 2 of 4 7/10/2017 P.O.1313:03 .01E y SCbra1619011E209101229 P306.3t33330148.`r,q. y3.3MAC133, .4oheenargfrow ie .ccrt_ ACTI4si ' F P ENE r SO itc 111 CONDUCTOR SIZING icinot Roof Pass Thru Box to DC Disconnect/Inverter: DRB APPROVED 9/5/2017 12:00:00 AM Max Inverter Input Circuit 13A 13A x 125% = 16.25A 690.8 (B)(1) #10 THWN-2 Table 310.16 40A (75°C column) Conduit fill adjustment Table 310.15 (B)(2)(a) No Conduit Fill Temperature correction factor Table 310.16 40A x .77 = 30.8A From Inverter to AC Disconnect/Production Meter/Backfeed Point: Nameplate maximum continuous output current: 16A 16Ax 125% =20A #10 THWN-2 Table 310.16 40A (75°C column) No Conduit fill adjustment Table 310.15 (B)(2)(a) No Temperature correction factor Table 310.16 Overcurrent Protection Devices 1 - 20A two pole breaker Backfeed Breaker Conductors may be oversized for Voltage Drop Page 3 of 4 7/10/2017 PD.EB:0704.k6r4 bra1619011E20910p229I 306.3133330148.`r,q. 13.8 .51C133, .4cItiwenarguasca ie .ccrt_ WEI F go 1 4,iali dt rrl 4. itt Line Diagram , ,DRB Baggaley Residence 4.48 kW Utility Interactive Photovoltaic APPROVED 4352 Spruce Way#5 System A2017 12:00:00 M Vail,CO.81657 Modules: 14 X LG320N1C-G4 Array mounted on roof VoC=40.9V 14 LG320N1C-G4 Solar Panels ISC= 10.05A 14 SolarEdge P320 DC Optimizers Optimizers: 14 SolarEdge P320 1 2 3 ••• 1< 1 String X 14 Modules/Optimizer i Inverter:SolarEdge SE3800A-US • Ll I Operating Voltage:350V Operating Current:9.53A Max System Voltage:500V 2#10 PV Wire Max Output Current: 15A 1#6G Bare Cu Conductors in Free Air Tilt Angle:26.57° Array Azimuth:220° Production:4,612kW h/yr Placard stating "Photovoltaic System Connected" And map of production meter location Pass Thru Per Holy Cross requirements Notes: Box Net Meter -See Calculation Sheet for conductor Located on Roof Located in north side sizing. `50' of unit 3 -All conductors are copper unless 'xi"EMT/MC Cable I 2#10 THWN-2 otherwise noted. 1#10 G THWN-2 -Inverter listed(UL-1741)to de- `5' Service Panel energize upon loss of utility voltage %"C EMT/PVC Located in the home per NEC 690.61. 3#10 THWN-2 -Inverter has integral ground-fault 1#10 G THWN-2 *_ protection per NEC 690.5 • -240V 1 Phase Service Panel rating I . Production • of 150A(bus rating 150 amp and 150 Meter • Backfeed Main disconnect)to accommodate �I On south wall Breaker ._ 2P 20A(PV)+ 150A(Main)= 170A 20A supply(up to 120%of connected SolarEdge SE3800A-US Inverter w/Integrated Disconnect -5'• A I ^ 240v power sources from installations per NEMA 3R 3/,"C EMT/PVC NEC 705(D)(2)(3)(b) Max AC Output:16A @ 240V 3#10 THWN-2 r, With ARC Fault Protection&Rapid Shutdown compliant- 1#10 G THWN-2 adjacent to production meter DC Grounding Electrode Conductor solid bare#6 Cu,per NEC 250.66(C) Page 4 of 4 7/10/2017 P.O.Box 7627,Avon,CO 81620 1 P: 970.306.4233 1 F: 866.403.3485 1 www.activeenergies.com 0 LG Innovatio 1 Life's Good4' 1 a Better MI ki. t, -ic�o viva DRB -------- AM 20107E:00:00 --------- MIIIMMEIIIMMinnt MilEMMMMiMMIMIII MIEMMEIMMMMUI -------®®III LGN e0 N 2 LG320N1C-G4 LG315N1C-G4 LG310N1C-G4 LG305N1C-G4 LG's new module,NeONTM 2,adopts Cello technology.Cello technology replaces 3 busbars with 12 thin wires to enhanceGus APPROVED PRODUCT power output and reliability.NeONTM 2 demonstrates LG's DVE ( E t�.M 60 cell efforts to increase customer's values beyond efficiency.It !Ks Intertek features enhanced warranty,durability,performance under KM564573 BS EN 61215 real environment,and aesthetic design suitable for roofs. Photovoltaic Modules il 1g go Enhanced Performance Warranty =-""'•• High Power Output ==i== LG NeONTM 2 has an enhanced performance warranty. _ ____ ,_ Compared with previous models,the LG NeONTM 2 MiiiiiiiiiiiM The annual degradation has fallen from-0.7%/yr to Miiiiiiiiiiiffi has been designed to significantly enhance its output ----- -0.6%/yr.Even after 25 years,the cell guarantees 2.4%p - - - efficiency,thereby making it efficient even in limited space. more output than the previous NeONTM modules. Aesthetic Roof =____= Q Outstanding Durability ------ LG NeONTM 2 has been designed with aesthetics in mind; -22222______ With its newly reinforced frame design,LG has extended MiiiiiiiiiiiM thinner wires that appear all black at a distance.The MiiiiiiiiiiiM the warranty of the NeONTM 2 for an additional 2 years. ----- product may increase the value of a property with its """` Additionally,LG NeONTM 2 can endure a front load up to modern design. 6000 Pa,and a rear load up to 5400 Pa. _ Better Performance on a Sunny Day ____ Double-Sided Cell Structure _______ _' LG NeONTM 2 now performs better on sunny days thanks = The rear of the cell used in LG NeONTM 2 will contribute to _iiiii _ to its improved temperature coefficiency Miiiiiiiiiiin generation,just like the front the light beam reflected from -- -- '------------ the rear of the module is reabsorbed to generate a great amount of additional power. About LG Electronics LG Electronics is a global player who has been committed to expanding its capacity,based on solar energy business as its future growth engine.We embarked on a solar energy source research program in 1985,supported by LG Group's rich experience in semi-conductor,LCD,chemistry,and materials industry.We successfully released the first Mono X®series to the market in 2010,which were exported to 32 countries in the following 2 years,thereafter.In 2013,NeONTm(previously known as Mono X®NeON)won"Intersolar Award'which proved LG is the leader of innovation in the industry. el LGNeON 2 LG320N1C-G4 LG315N1C-G4 LG310N1C-G4 LG305N1C-G4 dt Ir CIO fili. Mechanical Properties Electrical Properties(STC*) .,) � ...1), -'3 Cells 6 x 10 320 W 315 W D41 0 , - - Cell Vendor LG MPP Voltage(Vmpp) 33.6 33.2 9 PTIED 2.5 9/5 APT 12:00:0 Cell Type Monocrystalline/N-type MPP Current(Impp) 9.53 9.50 AM9.45 9.39 Cell Dimensions 156.75 x 156.75 mm/6 x 6 inch Open Circuit Voltage(Voc) 40.9 40.6 40.4 40.1 s of Busbar 12(Multi Wire Busbar)0 Short Circuit Current(Isc) 10.05 10.02 9.96 9.93 Dimensions(L x W x H) 1640 x 1000 x 40 mm Module Efficiency(%) 19.5 19.2 18.9 18.6 64.57 x 39.37 x 1.57 inch Operating Temperature("C) -40-+90 Front Load 6000 Pa/125 psf 0 Maximum System Voltage(V) 1000 Rear Load 5400 Pa/113 psf Maximum Series Fuse Rating(A) 20 Weight 17.0±0.5 kg/37.48±1.1 lbs Power Tolerance(%) 0-+3 Connector Type MC4,MC4 Compatible,IP67 *STC(Standard Test Condition):Irradiance 1000 W/m',Module Temperature 25°C,AM 1.5 Junction Box IP67 with 3 Bypass Diodes *The nameplate power output is measured and determined by LG Electronics at its sole and absolute discretion. *The typical change in module efficiency at 200 W/m'in relation to 1000 W/m'is-2.0%. Length of Cables 2 x 1000 mm/2 x 39.37 inch Glass High Transmission Tempered Glass Electrical Properties(NOCT*) Frame Anodized Aluminum 320W 315W 310W 305W Certifications and Warranty Maximum Power(Pmpp) 234 230 226 223 MPP Voltage(Vmpp) 30.7 30.4 30.0 29.7 Certifications(In Progress) IEC 61215,IEC 61730-1/-2,UL 1703, MPP Current(Impp) 7.60 7.58 7.54 7.49 ISO 9001,IEC 62716(Ammonia Test), Open Circuit Voltage(Voc) 37.9 37.6 37.4 37.1 IEC 61701(Salt Mist Corrosion Test) Short Circuit Current(Isc) 8.10 8.08 8.03 8.01 Module Fire Performance Type 2(UL 1703) *NOCT(Nominal Operating Cell Temperature):Irradiance 800 W/m2,ambient temperature 20°C,wind speed 1 m/s Product Warranty 12 years• Output warranty of PmaxLinear warranty* Dimensions(mm/in) (measurement Tolerance±3%) t e ' *1)1st year 98%,2)After 2nd year 0.6%p annual degradation,3)63.6%for 25 years - - -i. Temperature Coefficients L-11 NOCT 46±3°C e j o�a Pmpp -0.38%/°C Ji VOC -0.28%/°C Glenn* 0.0.10 Detail w°g eme name s6°,e rme rr.me Isc 0.03%/°C 0.16 Characteristic Curves ,.„ `�' a„° en °-;�at..�„ y.s ILO x,000w (..d, 30 g 10.00 . 8.00 6.00 eoo t1.we.1.q.) 4.00 =WM11\ 2.00 u t 1 Voltage(V) 0.00 500 10.00 15.00 20.00 25.00 30.00 35.00 40.00 45.00 - - 1 e 1 B 140 - k _ iS - n. 120 Isc 100 _ Voc N 80 Pmax 604,111„111141111111111111011 20 °°I ______VIII__IIIIIIIIII111111_IIIIIIIIIIIIIIIIIIIIIIIIIIIIIII_ 0 Temperature eC) ao -26 0 zs 50 75 90 *The distance between the center of the mounting/grounding holes 0 North America Solar Business Team Product specifications are subject to change without notice. LG LG Electronics U.S.A.Inc DS-N2-60-C-G-F-EN-50427 ❑1A❑ Life's Good 1000 Sylvan Ave,Englewood Cliffs,NJ 07632 - Copyright©2015 LG Electronics.All rights reserved. Innovation for a Better Life Contact4.51 Ig.solar@Ige.com 01/04/2015 r 1 www.lgsolarusa.com solar V, .1., z DRB SolarEdge Power Optimizer 9/5AM2017APPRV2:00:00 Module Add-On For North America P300 / P320 / P400 / P405 I .Qewer0 / .,.,' Ns ( :€) it ,0- v•Jaziov d- / 1//JJ f f...,/ ,, ' „J r' PV power optimization at the module-level — Up to 25% more energy — Superior efficiency(99.5%) — Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading — Flexible system design for maximum space utilization — Fast installation with a single bolt — Next generation maintenance with module-level monitoring — Module-level voltage shutdown for installer and firefighter safety USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us Nati OF gr ,aii solar - . • w SolarEdge Power Optimizer itc 4.71 Module Add-On for North America oj 0,5 P300 / P320 / P400 / P405icor l DRB APPROVED 9/5/2017 12:00:00 P300 P320 P400 P405 AM (for 60-cell modules) (for high-power (for 72&96-cell (for thin film 60-cell modules) modules) modules) INPUT Rated Input DC Powerltl 300 I 320 400 405 W • Absolute Maximum Input Voltage 48 80 125 Vdc (Voc at lowest temperature) _ MPPT Operating Range 8-48 8-80 12.5-105 Vdc Maximum Short Circuit Current(Isc) 10 11 10 Adc Maximum DC Input Current 12.5 13.75 12.5 Adc Maximum Efficiency 99.5 _ Weighted Efficiency 98.8 Overvoltage Category II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current15 _ Adc Maximum Output Voltage 60 I 85 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power 1 Vdc Optimizer STANDARD COMPLIANCE EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 _ Safety IEC62109-1(class II safety),UL1741 _ RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 _ Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters _ 128 x 152 x 27.5/ 128x152x35/ 128x152x48/ Dimensions(WxLxH) 5x5.97x1.08 5x5.97x1.37 5x5.97x1.89 mm/in Weight(including cables) 770/1.7 930/2.05 930/2.05 _ gr/lb Input Connector MC4 Compatible _ Output Wire Type/Connector Double Insulated;MC4 Compatible . Output Wire Length 0.95/3.0 1 1.2/3.9 m/ft . Operating Temperature Range -40-+85/-40-+185 _ °C/°F Protection Rating IP68/NEMA6P _ . Relative Humidity 0-100 I'I Rated STC power of the module.Module of up to+5%power tolerance allowed. PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTER(2) Minimum String Length 8 10 18 (Power Optimizers) Maximum String Length 25 25 50 (Power Optimizers) , Maximum Power per String 5250 6000 12750 W Parallel Strings of Different Lengths Yes or Orientations (3)It is not allowed to mix P405 with P300/P400/P600/P700 in one string. CE Eta ©SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All other trademarks mentioned herein are trademarks of their respective owners.Date:02/2015 V.01.Subject to change without notice. *11 OF P4 solar - • • --- DRB SolarEdge Single Phase Inverters APPROVES 9/5/2017 12:00:00 AM For North America SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / SE7600A-US / SE10000A-US / SE11400A-US 4 yea `':,'o,Wart 4a;aa0� • 7 i ��. The best choice for SolarEdge enabled systems ▪ Integrated arc fault protection (Type 1)for NEC 2011 690.11 compliance — Superior efficiency(98%) — Small, lightweight and easy to install on provided bracket — Built-in module-level monitoring — Internet connection through Ethernet or Wireless — Outdoor and indoor installation — Fixed voltage inverter, DC/AC conversion only — Pre-assembled Safety Switch for faster installation — Optional—revenue grade data,ANSI C12.1 USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL www.solaredge.us sati OF gr le Phase Inverters for North Americ � 16 Solar ` � • Sing SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US/ {" 4 Z SE7600A-US/SE10000A-US/SE11400A-US ' ' 107 SE3000A-US SE3800A-US SE5000A-US SE6000A-US SE7600A-US SE10000A-USI SE11400A-b OUTPUT APts APPROVFJ'f Nominal AC Power Output 3000 3800 5000 6000 7600 9980 @ 208V 1 9(6/02017 12:OOVA 10000 @240V• �d Max.AC Power Output 3300 4150 5400 @ 208V 6000 8350 10800 @ 208V 12000 VA 5450 @240V 10950 @240V AC Output Voltage Min:Nom:Max.11i 183-208-229 Vac r r • AC Output Voltage Min.-Nom.-Max.111 ✓ ✓ ✓ I V V V V 211-240-264 Vac AC Frequency Min.-Nom.-Max.0l f 59.3-60-60.5(with HI country setting 57-60-60.5) Hz Max.Continuous Output Current f 12.5 111 1 16 I 21 @ 240V f 25 1 32 I 42 @ 240V I 47.5 A • G F D I I 1 A Utility Monitoring,Islanding Protection,Country Configurable Thresholds Yes Yes INPUT Recommended Max.DC Power121 3750 1 4750 6250 7500 9500 12400 14250 W .(STC) 1 1 . Transformer-less,Ungrounded Yes Max.Input Voltage 500 Vdc Nom.DC Input Voltage 325 @ 208V/350 @ 240V Vdc Max.Input Currentlal 9.5 f 13 16.5 @ 208V f 15.5 @ 240V f 18 23 @ 208V I 3035 @ 240V f 34.5 Adc Max.Input Short Circuit Current f 45 Adc Reverse-Polarity Protection If Yes Ground-Fault Isolation Detection 600ka Sensitivity Maximum Inverter Efficiency 97.7 98.2 98.3 98.3 98 98 1 98 CEC Weighted Efficiency 97.5 98 97.5 @ 208V 97.5 97.5 97 @ 208V f 97.5 % 98 @ 240V 97.5 @ 240V • Nighttime Power Consumption L <2.5 <4 W ADDITIONAL FEATURES Supported Communication Interfaces I RS485,RS232,Ethernet,ZigBee(optional) •. Revenue Grade Data,ANSI C12.1 Optionall4i, f Rapid Shutdown-NEC 2014 690.12 If Functionality enabled when SolarEdge rapid shutdown kit is installed') If STANDARD COMPLIANCE Safety UL1741,UL1699B,UL1998,CSA 22.2 Grid Connection Standards IEEE1547 Emissions FCC partly class B INSTALLATION SPECIFICATIONS AC output conduit size/AWG range I 3/4"minimum/16-6 AWG 3/4"minimum/8-3 AWG DC input conduit size/#of strings/ AWG range 3/4"minimum/1-2 strings/16-6 AWG 3/4"minimum/1-2 strings/14-6 AWG Dimensions with Safety Switch 30.5 x 12.5 x 7/ 30.5 x 12.5 x 7.5/ 30.Sx12.5x10.5/775x315x260 in/ ,(HXWXD) 775x315x172 775x315x191 mm . Weight with Safety Switch 51.2/23.2 54.7/24.7 88.4/40.1 lb/kg Cooling f Natural Convection Fans(user replaceable) Noise <.25 <50 dBA Min.-Max.Operating Temperature -13 to+140/-25 to+60(-40 to+60 version available161) °F/°C Range . • Protection Rating NEMA 3R 1�1 For other regional settings please contact SolarEdge support. 1zi Limited to 125%for locations where the yearly average high temperature is above 77°F/25°C and to 135%for locations where it is below 77°F/25'C. For detailed information,refer to httn://www.solaredae.us/files/adfs/inverter dc oversizinz euide.odf 131A higher current source may be used;the inverter will limit its input current to the values stated. 14)Revenue grade inverter P/N:SExxxxA-US000NNR2 Ri Rapid shutdown kit P/N:SE1000-RSD-S1 (6i-40 version P/N:SExxxxA-US000NNU4 ETA 141=1 RoHS ©SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All other trademarks mentioned herein are trademarks of their respective owners.Date:07/2014.V.01.Subject to change without notice.