30'
42'30'
42'Proposed Floor Plan
Scale- 1/4" = 1'
Kitchen Area-
Final Layout TBD
Bench/ Cubbies
42" tall wall
Arched
Opening
Original/ Existing Floor Plan
Scale- 1/4" = 1'
Bedroom #1
Master Bedroom
A1
General Notes
1- Complete interior remodel of existing unit including
all new finishes, new cabinetry, and new fixtures
2- Modify framing/ wall locations for new proposed
layout, no structrual changes all changes are to
partition walls
3- 6" round outside corners where porssible
4- New lighting layout as shown above, At least 75%
of new lighting to be high efficiency, any recessed can
lights are to receive tent/ hat to maintain fire ratings
5- Plumbing to be modifed for new layot, any
penetrations to maintain required fire ratings
6- Mechanical- Existing heating sytem to reamin new
exhaust fans for bathroom and kitchen hood
7- Verify carbon monoxide detector installed
8- Asbestos testing required
9- Verify all elec/ mech meets current code
Remove existing bathroom
finishes and fixtures, adjust
plumbing and framing for
new layout as needed
Remove hallway walls and
doors (non structural) for
more open living room area
Remove and eliminate existing
bathroom/ powder room tio allow
for completely remodeled larger
kitchen area with new finishes,
cabinets, fixtures and
appliances
2015 INTERNATIONAL BUILDING CODE
2015 INTERNATIONAL FIRE CODE
2015 INTERNATIONAL MECHANICAL CODE
2015 INTERNATIONAL PLUMBING CODE
2012 FUEL AND GAS CODE
2015 INTERNATIONAL ENERGY CONSERVATION CODE
2014 NATIONAL ELECTRICAL CODE
2015 INTERNATIONAL EXISTING BUILDING CODE
TOWN OF VAIL AMENDMENTS
TYPE OF CONSTRUCTION V-B
OCCUPANCY R-1, B
ALLOWABLE AREA 21,000 S.F. (BEFORE MODIFIERS)
PROPOSED AREA NO CHANGE TO EXISTING
ALLOWABLE HEIGHT 60-0 AND 3 STORIES (EXISTING 2 STORIES)
PROPOSED HEIGHT NO CHANGE TO EXISTING
THE EXISTING BUILDING HAS AN APPROVED AUTOMATIC FIRE SPRINKLER
SYSTEM INSTALLED.
OCCUPANCY SEPARATION R-1 TO B1 HOURS
FIRE RESISTANCE RATING PER TABLE 601
PRIMARY STRUCTURAL FRAME 0 HOURS
EXTERIOR BEARING WALLS 0 HOURS
EXTERIOR NON-BEARING WALLS 0 HOURS
INTERIOR BEARING PARTITIONS 0 HOURS
INTERIOR NON-BEARING PARTITIONS 0 HOURS
FLOOR 0 HOURS
ROOF 0 HOURS
FIRE RESISTANT WALL RATING BETWEEN UNITS PER 708.3 EXCEPTION 2
AND 711.2.3.4 SHALL BE 1/2 HOUR. FIRE RESISTANT FLOOR ASSEMBLY
BETWEEN UNITS PER 711.2.4.3 SHALL BE 1/2 HOUR. SEE ATTACHED
ESR-1153 FOR RATED FLOOR ASSEMBLY. REFER TO FIGURE 4A AND
ALTERNATE FLOOR ASSEMBLY FOR GYPCRETE ASSEMBLY.
NO WORK IS PROPOSED AT THE EXISTING EXTERIOR
WALLS OR ROOF.
EXISTING FIRE SPRINKLER SYSTEM AND FIRE ALARM
SYSTEM TO REMAIN. MODIFICATIONS SHALL BE MADE AS
REQUIRED.
PROPOSED PLUMBING FIXTURE COUNT: NO CHANGE.
ALL NEW PLUMBING FIXTURES, ETC. SHALL COMPLY WITH
CURRENT ENERGY CODES AS ADOPTED BY THE TOWN OF
VAIL.
CODE INFORMATION
NEW GAS INSERT
DEMO STONE
NEW FACADE
TV LOCATION TBD
SWING ARM
SCONCES
R
R
R R
TV
XL
TWINS
39"x80"
T
V
R R
RANGE HOOD VENT
TO EXTERIOR
RANGE HOOD
EXHAUST LESS
THAN 400 CFM
LAUNDRY FLOOR
DRAIN
DRYER SHALL BE VENTED TO THE
EXTERIOR. VENT LENGTH SHALL
NOT EXCEED MANUFACTURER'S
RECOMMENDATIONS
10- All revised mechanical ducts penetrating rated assemblies
shall have fire dampers and shall match the rating of ceiling/floor
assembly as required.
MUST COME FROM
THE SAME STACK AS
ELMINIATED
BATHROOM
09/07/17