HomeMy WebLinkAboutB17-0273_Wolk Drawing_1504804560.pdfR R R R R R R R R R R R R R R R R R R R R R R R R R R 30' 42'30' 42'Proposed Floor Plan Scale- 1/4" = 1' Kitchen Area- Final Layout TBD Bench/ Cubbies 42" tall wall Arched Opening Original/ Existing Floor Plan Scale- 1/4" = 1' Bedroom #1 Master Bedroom A1 General Notes 1- Complete interior remodel of existing unit including all new finishes, new cabinetry, and new fixtures 2- Modify framing/ wall locations for new proposed layout, no structrual changes all changes are to partition walls 3- 6" round outside corners where porssible 4- New lighting layout as shown above, At least 75% of new lighting to be high efficiency, any recessed can lights are to receive tent/ hat to maintain fire ratings 5- Plumbing to be modifed for new layot, any penetrations to maintain required fire ratings 6- Mechanical- Existing heating sytem to reamin new exhaust fans for bathroom and kitchen hood 7- Verify carbon monoxide detector installed 8- Asbestos testing required 9- Verify all elec/ mech meets current code Remove existing bathroom finishes and fixtures, adjust plumbing and framing for new layout as needed Remove hallway walls and doors (non structural) for more open living room area Remove and eliminate existing bathroom/ powder room tio allow for completely remodeled larger kitchen area with new finishes, cabinets, fixtures and appliances 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL FIRE CODE 2015 INTERNATIONAL MECHANICAL CODE 2015 INTERNATIONAL PLUMBING CODE 2012 FUEL AND GAS CODE 2015 INTERNATIONAL ENERGY CONSERVATION CODE 2014 NATIONAL ELECTRICAL CODE 2015 INTERNATIONAL EXISTING BUILDING CODE TOWN OF VAIL AMENDMENTS TYPE OF CONSTRUCTION V-B OCCUPANCY – R-1, B ALLOWABLE AREA – 21,000 S.F. (BEFORE MODIFIERS) PROPOSED AREA – NO CHANGE TO EXISTING ALLOWABLE HEIGHT – 60’-0” AND 3 STORIES (EXISTING 2 STORIES) PROPOSED HEIGHT – NO CHANGE TO EXISTING THE EXISTING BUILDING HAS AN APPROVED AUTOMATIC FIRE SPRINKLER SYSTEM INSTALLED. OCCUPANCY SEPARATION – R-1 TO B1 HOURS FIRE RESISTANCE RATING PER TABLE 601 PRIMARY STRUCTURAL FRAME 0 HOURS EXTERIOR BEARING WALLS 0 HOURS EXTERIOR NON-BEARING WALLS 0 HOURS INTERIOR BEARING PARTITIONS 0 HOURS INTERIOR NON-BEARING PARTITIONS 0 HOURS FLOOR 0 HOURS ROOF 0 HOURS FIRE RESISTANT WALL RATING BETWEEN UNITS PER 708.3 EXCEPTION 2 AND 711.2.3.4 SHALL BE 1/2 HOUR. FIRE RESISTANT FLOOR ASSEMBLY BETWEEN UNITS PER 711.2.4.3 SHALL BE 1/2 HOUR. SEE ATTACHED ESR-1153 FOR RATED FLOOR ASSEMBLY. REFER TO FIGURE 4A AND ALTERNATE FLOOR ASSEMBLY FOR GYPCRETE ASSEMBLY. NO WORK IS PROPOSED AT THE EXISTING EXTERIOR WALLS OR ROOF. EXISTING FIRE SPRINKLER SYSTEM AND FIRE ALARM SYSTEM TO REMAIN. MODIFICATIONS SHALL BE MADE AS REQUIRED. PROPOSED PLUMBING FIXTURE COUNT: NO CHANGE. ALL NEW PLUMBING FIXTURES, ETC. SHALL COMPLY WITH CURRENT ENERGY CODES AS ADOPTED BY THE TOWN OF VAIL. CODE INFORMATION NEW GAS INSERT DEMO STONE NEW FACADE TV LOCATION TBD SWING ARM SCONCES R R R R TV XL TWINS 39"x80" T V R R RANGE HOOD VENT TO EXTERIOR RANGE HOOD EXHAUST LESS THAN 400 CFM LAUNDRY FLOOR DRAIN DRYER SHALL BE VENTED TO THE EXTERIOR. VENT LENGTH SHALL NOT EXCEED MANUFACTURER'S RECOMMENDATIONS 10- All revised mechanical ducts penetrating rated assemblies shall have fire dampers and shall match the rating of ceiling/floor assembly as required. MUST COME FROM THE SAME STACK AS ELMINIATED BATHROOM 09/07/17