FIRE ALARM PERMIT
Commercial and Residential Fire Alarm shop drawings are required at the time of application submittal and must
included information listed on the 2nd page of this form. Application will not be accepted without this information.
Project Street Address: Office Use:
385 Gore Creek Drive #103
Project#:
(Number) (Street) (Suite#)
Building/Complex Name:
Vorlaufer#103 Building Permit#:
Alarm Permit#:
Contractor Information: Lot#: Block# Subdivision:
Company: Superior Alarm&Electronics
Company Address: PO box 4910 Detailed Scope and Location of Work:
City: Edwards State: CO Zip.81632 Fire system upgrade . The unit currently under
Contact Name: Office-Doris renovation
Contact Phone: 970-926-8788
E-Mail
Boris@superioralarmco.com (use additional sheet if necessary)
Does a Monitored Fire Alarm Exist? Yes Q No 0
I hereby acknowledge that I have read this application,filled out in
full the information required,completed an accurate fire alarm sys- Does a Sprinkler System Exist? Yes 0 No 0
tern drawings and state that all the information as required is cor-
rect. I agree to comply with the information and fire alarm system Work Class:
drawings,to comply with all Town ordinances and state laws,and to
build this structure according to the towns zoning and subdivision New(0 Addition(0 Remodel(0 Repair(0)
codes, design review approval, National Fire Code, International Retro-Fit(0 Other(0
Building and Residential Codes and other ordinances of the Town
applicable thereto. Type of Building:
Digitally signed by Dolls Medina
ON:cmDorlsMedlna.o=Superior Alarm&Electrontcs;i.tC.tau,emall-doois&asuperioralaonco.com,c-US Single-Family 0) Duplex(( Multi-Family(0
X Date:2014.05.29 09.513,17,06'00'
Commercial(Q Restaurant(0 Other 0
Contractor Signature(required)
Property Information
for Fire Alarm Pe t:Complete Va /�
Parcel#: 2103-082-32-003 Fire Alarm$: no.0luation0
(For parcel#,contact Eagle County Assessors Office at 970-328-8640 or
visit www.eaglecounty.uslpatie)
Tenant Name: House Hold Furnishings Date Received:
Owner Name: Rose Lands Inc
13-Apr 01
�p1L FIRg`�
fT
Fire Department Process
For Commercial & Residential Fire Alarm Systems
Commercial and Residential Fire Alarm shop drawing requirements at the time of submittal must include the
following:
x A Colorado Registered Engineer's stamp
x Device locations on reflected ceiling plans
Reflected Ceiling Plans (RCP)
x Typical device wiring diagrams
x Battery calculations
x Battery calculations
x A list of specific device model numbers
x Equipment cut sheets of each type of device
x The number of each type of device
x Information indicating the specific zones
x Circuit diagrams
x Point to point wiring diagram
x Wiring type, size and number of conductors
The source of AC power circuits
x Fire alarm panel locations
x Knox Box location
x Information indicating monitoring method and monitoring agency
This check list has been provided to ensure that our review process may be handled in a timely manner.
I have read and understand the above listed submittal requirements:
Project/Street Address: Vorlaufer/385 Gore Creek Drive Unit 103, Vail Colorado
Contractor Signature: 01.L04¢Qms9
Date Signed: 05/29/2014
01-feb-10
_., _
.i. ,_,.., ,,,ge.......,..v.,
‘.. ...._;;;; _.. ,,,
,,,o .. .. ,..,,,,,
.,z).., „.:7,,..,, , ez?
...:0 ,ev_ 04 Fire Department Guidelines
For Preventing Non-Emergency Fire Alarms
k Q�NCY £n-
40
In order to prevent a non-emergency response from the Vail Fire Department Suppression crews to the con-
struction location you may be working on, we ask that you perform the following tasks:
Determine what kind of fire alarm system exists within the structure you are
working in with the owner or the manager of the property involved or by contact-
X ing the Vail Fire Department.
Determine with the owner or manager of the property, which alarm company
x services the system for them
Become familiar with the different components that are associated with the fire
X alarm system and how they operate before the DEMO begins.
Never paint a smoke detector, thermal detector, or any other component of the
X fire alarm system and never paint a sprinkler head/cover plate.
For larger projects, please contact the Vail Fire Department so that we can
work with you in determining what needs to be done to alter or"Zone Out" spe-
cific areas of the alarm system for the structure.
Please contact the Vail Fire Department at 479-2252.
I have read and understand the above listed submittal requirements:
Project/Street Address: Vorlla pfer!385 Gore Creek Drive Unit 103, Vail Colorado
DIgIM
DN:cnsDods Medna.o=5uperio<Alam&Llecironics.at,ou,emaIt.dorlst3supedoralarmco.corn,c-US
Contractor Signature: Dat e:2014.05291044.51-4660'
Date Signed: 05/29/2014
01-R3g-10
,• t}�1L T4e:: ,
Fire Department Guidelines
dh l Pre-Plan Information Sheet
lF
BUILDING INFORMATION:
Building Name:
Street Address & Phone#: 385 Gore Creek Drive, #103, Vail Colorado
Knox Box Location:
Alarm Panel Location: In Mech room
Vail Fire & Emergency Services
Alarm Silence & Rest Codes: 2251
RPS': Names & Phone Numbers (Work& Home)
Owner:
Property Manager: 1151 '
Property Maintenance Mgr: 113D
Alarm Service Company: Superior Alarm & Electronics -- g9cr,
BUILDING UTILITIES:
Gas:
Main Location:
Other Locations:
Electric:
Main Location:
Other Locations:
Water:
Main Valve Location:
Main Fire Valve Location:
Secondary Fire Valve Loc:
01-Feb-10