HomeMy WebLinkAboutFA-01.pdf LEGEND : SYMBOL DEVICE MANUFACTURER/PART# MOUNTING FACP Caddx (NetworkX) NX-8E Fire Alarm Control Panel w/NX-2192 Addressable Card Mount on wall in manufacturer backbox KP LCD Keypad/Annunciator Caddx (NetworkX) NX-148E Mount on wall in manufacturer backbox Combination Smoke & Heat Detector w/Sounder System Sensor i3 series 4WTA—B 4" square box z Combination Smoke and o Oco CO Detector w/Sounder System Sensor i4 series COSMO-4W 4" square box 11 PULL DOWN I - ATTIC STAIR 1W _ u9 �= W LAUNDRII' - ® Heat Detector System Sensor 5601 P 4" square box z z Ar T� ee o 0 �' P 4 PSTORAGE E Addressable Monitor Module SI—ID Addressable Module > W N- \ 2 STORAGE II KB Knox Box 7 71 ** Fire 4'lall GLASSFLOO O\ Horn/Strobe, weatherproof System Sensor P2RK Weatherproof backbox CB I- ABOVE _/ ____. o POOL EQUIP L \ CRAWL SPACE — - o iii f i\Ii GENERAL NOTES: \ 0 MUD RM W+----- � \ SHAT-� 1 . ALL EQUIPMENT IS TO BE INSTALLED AND TESTED IN ACCORDANCE WITH CO 1 '' ,)== MANUFACTURER MANUFACTURER STANDARDS, FIRE DEPARTMENT REQUIREMENTS AND NFPA 72. 0 �+ WOOD VENEER 2. REFER TO MANUFACTURERS DATA SHEETS AND INSTALLATION INSTRUCTIONS FOR Z -L — Q Q r )1PANELS FURTHER INFORMATION REGARDING PRODUCT INSTALLATION, WIRING DIAGRAMS, 0 FACP CRAWL SPACE 010 TO FAP PROGRAMMING AND DEVICE OPERATION. 0 1 _� LL 007 HI 008 �T\ 01 V TO FAC 009 a ©CO ABOVEFLO,F� II - 0 \ ) CO + +1 I I I 1 W GARAGE \ ` \ � / PANELS DENEER O _+ oy \ \° j TO FACP / TO FIACI' GLASS FLOO/ I} W co i + ABOVE / f I HA \ _ /\ ' 011 0 co co 00 11- TO FACP o © O K �3EDR001� n = O o Ts — L A \ WOOD VENEER O T i�©r PANELS rc— Ca .. (�� S ISHADE p I HADE O (3) >- 0 > 6 m11111 1 J A [10 ci I ICY Ea GROUND FLOOR PLAN RISER NOTES: D = 4-WIRE DATA/POWER, 4-#16AWG (2 PAIR) Q rn SCALE: 1/8" = 1' 1. REFER TO CADDX NX-8E INSTALLATION MANUAL X = 2—WIRE DATA, 2—#16AWG FOR MORE INFORMATION. N = 2-WIRE SOUNDER CIRCUIT, 2-#18AWGU .- 2. WIRE SIZE MAY BE VARIED, PROVIDED IT MEETS MANUFACTURERS SPECIFICATIONS. L = 2-WIRE DATA CIRCUIT, 2-#16AWG ..... ¢ KP = KEYPAD CIRCUITING, 4-#18AWG I I *om a C °LEO \ 2 2 co � .r t • D D X ..STORAGE L © M M NX8E (TYP) (TYP) (TYP) CONTROL PANEL 120VAC DEDICATED POWER i TELEPHONE LINE - FIREWP TELEPHONE LINE — SECURITY OUTPUT N O, EOLR COCO C0 CADDX RISER DIAGRAM DAOUTPUT KP NX148 1 KEYPAD 0 7T T N- ICP EV EQUIP MONITOR SPRINKLER - 001 WATERFLOW & TAMPER \ SWITCH WITH ‘W ‘W E r, -I / ADDRESSABLE THEATER GAME Cn MODULES. USE ZONES \ U 3 3 002 & 003. \ 0+' pFI bye RE"4° .'sf Cak', ,;...... z W OFFICIE - di \\ --4 . e:v.,,. r Ct \ I - PROJECT NFORNATION : : �. ���s�p �, � �I :V'GARAGE 4-; 414 3 0 3 IV I L L CREEK CIRCLE ' ,, • ' , w; U 004 GLASSFL - L SEQUENCE OF z = .-• •.p�y,.. w z TO FACP ABOVE a 0 o n c� a o •Ssi4fVA� '' J Q O TO FACP ©co \ \ \ / 1 OPERATIONS: w Z z z z o VAIL COLORADO '""--��•"'''�' J w 005 -� \ \ • 00611 m �, o 0 o cn o o 0 J 0 _ WINE _ \ — _ \ TO FACP \\ o zN N1- > 1- J1- m FIRE ALARM SYSTEM m \, , 0 Q oo � cn wcn co (i) z 1-11 w �I WINE \ GAME o_ _ = g z z z m w AHJ: VAIL FIRE (Sc EMERGENCY SERVICES 0 0 = \� a Z 0 Q I- NI- ~ a o APPLICABLE CODES: 2010 NFPA 72, 2012 IFC, 2012 IBC w � � � 0 � 0 � � c� O � 0 Lu w = � z � z � z w w w N OCCUPANCY: GROUP R w < � � ASEN E \ T PLA \ DEVICE Q No No w > > O z - z - z - > z > z USE: SINGLE FAMILY HOME CO DESCRIPTION � w go go go � D � ' Ct 0 SCALE: 1/8" 1' < < a oN a oz FIRE ALARM SYSTEM FOR SINGLE FAMILY HOME. SYSTEM WILL INCLUDE A 0 J 0 NEW ADDRESSABLE FACP. COMBINATION SMOKE/HEAT DETECTORS WILL BE J 0 < w INSTALLATION NOTES: SMOKE DETECTOR X X X U 1 Z INSTALLED IN SLEEPING ROOMS WITH SMOKE/HEAT/CO DETECTORS ON I— 0 1 . SMOKE DETECTORS IN SLEEPING ROOMS SHALL BE CENTERED ALONG ONE WALL X X X STAIRWELL LANDINGS, WITHIN 15' OF FIREPLACES AND AREAS OUTSIDE OF J^ Z (n Cr)HEAT DETECTOR SLEEPING ROOMS. A HEAT DETECTOR WILL BE INSTALLED IN THE 0 w OF ROOM AND LOCATED A MINIMUM OF 12" OFF THAT WALL. — - - - GARAGE. DETECTORS HAVE INTEGRAL SOUNDERS. A KNOX BOX WILL BE OM � 0 � 2. IF ELEVATOR EQUIPMENT ROOM IS SPRINKLERED, PROVIDE A HEAT DETECTOR FOR CARBON MONOXIDE DETECTOR X X X MOUNTED ON THE OUTSIDE OF THE HOME. SHUNT TRIP. SHEET DESCRIPTION: SPRINKLER WATERFLOW SWITCH X X X X FIRE ALARM PLAN FIRE PROTECTION ENGINEER: SPRINKLER TAMPER SWITCH X X DEBORAH SHANER, P.E., SHANER LIFE SAFETY DRAWN BY: DATE: PO BOX 1073, FRISCO, CO 80443 DLS 6/3/14 POWER LOSS, OPEN CIRCUIT, GROUND FAULT X X PHONE: 970-409-9082 1 _ FAX: 970-797- 1898 SHEET#: FA-01 Battery Calculations Caddx NX-8E Standby Number of Current Total Current Device Type Devices (Amps) (Amps) Main FACP CPU 1 ' X. 0.075 = 0.075 z 0 NX-14E LCD Keypad 1 X' 0.075 = 0.075 F NX-2192 Addressable Interface Card (max draw) 1 ' X' 0.17 - 0.17 E X SUM COLUMN FOR STANDBY LOAD 0.32 = AMPS v co Alarm Load 1 w 0 Number of Current Total Current — 6 Device Type Devices _ (Amps) (Amps) z c Main FACP CPU 1 X 0.14 = 0.14 o w NX-14E LCD Keypad 1 -X 0.11 = 0.11 w rI NX-2192 Addressable Interface Card 1 X 0.17 = 0.17 rr Sounders (integral with detectors) 13 X 0.015 = 0.195 Outside Horn/Strobe 1 X 0.239 = 0.239 SUM COLUMN FOR ALARM LOAD 0.854 = AMPS ;;_. ., °,. .,. ., F.---- � Standby Load Required Standby Time in Hours Current (Amps) yb iLu 2768eqTimeHours5 I I I I I I ±— ,I-I ■� — 0.854 X 0.25 = 0.21 / 1 I I I I I I.I�11� - o Add Standby and Alarm Load for Required -1 11I -4- 1 z Ampere Hour Battery 7.89 C C -[ I C W� � oo r " imiva,7-----7 Multiply by the Derating Factor of 1.2 " 1--1 1-- — 017 �'•/� CO Total Ampere Hours Required 9.47 .�i II ° rr 'CP ©Ce I—lIllir — Batteries Provided: 12AH 0 01 Nate: The maximum draw for the NX-2192 Addressable Interface Card was used. This accounts for all •• o * Z initiating devices (smokes and heats)attached to the system. Therefore, each device is not individually 016 0P ' REACING 0 accounted for. I I 671/ O , , ■°� _= n/ IIMASTER H 0 1 U - I BEDROOM ------- ---- 1 Address Type of Device Level Description I U P P E 1- 10 0 PLAN w co 001 SMOKE DETECTOR BSMT AT FACP II SCALE: 1 8" = 1' —I CO CO CO 002 MONITOR BSMT SPRINKLER WATERFLOW ° ° r7 0: . / 003 MONITOR BSMT SPRINKLER TAMPER SWITCH 0 Cfl 004 CO/SMOKE BSMT BOTTOM OF STAIRS = ,L° 0 005 HEAT DETECTOR BSMT LOWER GARAGE 006 SMOKE DETECTOR BSMT GAME ROOM • CO Z � 007 HEAT DETECTOR GROUND UPPER GARAGE 0 0 p 008 CO/SMOKE GROUND STAIR LANDING CO Q ti 009 CO/SMOKE GROUND OUTSIDE BEDROOMS is.1 -------------- '''''"'''— 010 SMOKE DETECTOR GROUND NE BEDROOM 011 SMOKE DETECTOR GROUND SE BEDROOM -- 012 CO/SMOKE MAIN LIVING ROOM 013 CO/SMOKE MAIN STAIR LANDING .1 ¢ 014 SMOKE DETECTOR MAIN READING ROOM mil'Em C 015 SMOKE DETECTOR MAIN WEST BEDROOM a }' 016 CO/SMOKE UPPER MASTER BEDROOM - 017 CO/SMOKE UPPER TOP OF STAIRS Air ,....„,cu 1 018 SPARE C 019 SPAREWii 0,,,..„............020 SPARE �021 SPARE10Aei , • _ - - 022 SPAREs__r 023 SPARE41) 024 SPARE -'r s 025 SPARE SC..iof — - 4 c- ----r— — — r ti,=., ' i Sij I 1 � r 0J - 1 1 11 11 1111 -- 00 GYM -___ ---711) /7 Or— 1 it 0 11 r--l ill A N w us. CL \\ 1114 ro...„___ C.) Ct � LLJ Z °.. .u. .■ Fuji �. 0 Z .. 1V READING RM MOM --- \ 4::t °�0� �r II CHEN cL �_ \\ /I I imiiii CO �� I� in .�PIM. CONING* it ILII W = 014 1 ' I• I� Li LLJ J W CL TO FACP , -_ 0 �����.° low II ���.,�, M 11110 . 01 � 1 � TO FACP © /�� � � � � �I��1 77- I -I fill --d -i/ I tCt � WI 7i-A �o �I_ © TO FACf� h 0 1- 0 r , -__ L___ \e-s. 0 . . El 015 =1_.. 117 gli IIr___. iir II I IL ... 7[01-2-1-o IWCL 0 m—.e.° I BALCONY ITo /ieic71 I '� 0 Q 1. ,° CLOSETILLI I — I — L. .I. J Q W ..... BEDROOM �i©� DINING ' II LIVI II II Jo cL 0 z _ , _, , ��� .. _er4, r .. (VAIN FL00PLAN SCALE: 1/8" = 1' • 4. T„ • U 121 . P � I �t 'Ffi SHEET DESCRIPTION: ; `�S' 3 vnzr 35233' Fon a'•- FIRE ALARM PLAN INSTALLATION NOTES: !� w 1 . SMOKE DETECTORS IN SLEEPING ROOMS SHALL BE CENTERED ALONG ONE WALL -".....:(e•i6tip&���'� DRAwN BY: DATE: �►QfVAF..-'� .� OF ROOM AND LOCATED A MINIMUM OF 12" OFF THAT WALL. . CELS 6/3/14 2. IF ELEVATOR EQUIPMENT ROOM IS SPRINKLERED, PROVIDE A HEAT DETECTOR FOR SHUNT TRIP. SHEET#: FA-02