Loading...
HomeMy WebLinkAboutA14-0028 cut sheets.pdfDescriptionSK-Photo and SK-Photo-T are plug-intype smoke sensors that combine aphotoelectric sensing chamber withaddressable analog communications.Point ID capability allows eachdetector’s address to be set with rotaryaddress switches, providing exactdetector locations for selectivemaintenance when chambercontamination reaches unacceptablelevels.SK-Photo and SK-Photo-T have aunique optical sensing chamber that isengineered to sense smoke producedby a wide range of combustionsources. In the SK-Photo-T, dualelectronic thermistors add 135ºF (57ºC)thermal technology to maximizedetection. Features•Sleek, low-profile design•Base included• Reliable analog communications fortrouble-free operation•Age resistant polymer housing•Dual electronic thermistor design onthe SK-Photo-T• Superior EMI resistance for reliability• Simple field cleaning for codecompliance• Variety of mounting options to meetany application• Dual LED indicators for 360º visibility• Detector transmits signal to indicatemaintenance is required• Optional remote LED annunciator(System Sensor® PN RA100Z) • Plug-in mounting provides ease ofinstallation• Tamper-proof feature available onmounting bases•Listed for use in duct applications•Rotary address switches for fastinstallation• UL Listed• FM Approved SpecificationsPhysicalHeight: 2.0” (5.0 cm)Diameter: 4.1” (10.4 cm)Shipping Weight: 5.2 oz. (147 g)ElectricalOperating Voltage: 15–32 VDCStandby Current:300 µA @ 24 VDC MaximumAlarm Current: 6.5 mA @ 24 VDC max(with LED on)EnvironmentalOperating TemperatureSK-Photo: 32º – 120ºF (0ºC – 49ºC)SK-Photo-T: 32º – 100ºF (0ºC – 38ºC)Humidity: 10% – 93% non-condensingOther RatingsSK-Photo-T Thermal: Fixedtemperature set point 135ºF (57ºC)Velocity: 0 – 4000 fpm (0 – 20 m/sec)SK-Photo Insect Screen Hole Size:0.016” (0.41 mm) nominal CompatibilityThe SK-Photo and SK-Photo-T arecompatible with the followingIntelliKnight FACPs:5820XL580857005600 (Rev 2.0 or higher)SK-Photo and SK-Photo-T arecompatible with the following detectorbases:B210LP 6” base (included)B501 2 wire baseB224RB Relay baseB224BI Isolator baseB200SR Sounder base SK-Photoand SK-Photo-T The SK-Photo is a photoelectric smoke detector and the SK-Photo-T is a photoelectric smoke detector withthermal. These plug in smoke detectors, with integral communication, provide features that surpass conventionaldetectors and are for use with Silent Knight IntelliKnight Fire Alarm Control Panels (FACPs).For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103. Intelligent Photoelectric Smoke Sensors SK-Photo (Base included) INTELLIKNIGHT ACCESSORY INTELLIKNIGHT ACCESSORYModel SK-Photo and SK-Photo-TIntelligent Photoelectric SmokeSensors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent photoelectric smoke sensorsSilent Knight SK-Photo or SK-Photo-T with thermal. The combination detector head, and twist-lock base, shallbe UL listed and compatible with Silent Knight’s IntelliKnight fire control panels.The base shall permit direct interchange with SK-Photo or SK-Photo-T. Base shall be the appropriate twist-lockbase part number B210LP (included).The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, theflashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch.The calibration of the detector shall be capable of being selected and measured by the control panel without theneed for external test apparatus.The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. Thelocking feature shall be field selectable as required.The SK-Photo shall automatically perform a functional test of the detector.The test method shall simulate effectsof products of combustion in the chamber to ensure testing of detector circuits. MADE IN AMERICA FORM# 350118 Rev C©2011 Honeywell International Inc. This document is not intended to be used for installation purposes. We try tokeep our product information up-to-date and accurate. We cannot cover allspecific applications or anticipate all requirements. All specifications aresubject to change without notice. For more information, contact Silent Knight12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com DescriptionB200SRThe B200SR Series sounder bases set a new standard forperformance, installation, and aesthetics. The B200SR isdesigned for new and existing dwelling unit applications. Itoffers maximum flexibility in installation, configuration, andoperation to meet or exceed UL 268 and UL 464requirements.The B200SR is fully compatible with existing B501BH-Seriessounder base installations. The device enables users toselect one of two B501-supported tones (ANSI Temporal 3 orContinuous) by removing a jumper.With its attractive aesthetics, the B200SR is ideal forapplications where appearance is critical. For example, thesounder base employs a separate mounting plate that installsonvarious junction box sizes to eliminate unsightly surface-mount boxes. In addition, the mounting plate enables pre-wiring of all connections to speed and simplify installation.The housing then mates with the mounting plate and islocked in position with two retaining screws, which arecovered by the installed sensor head for added tamperresistanceFeatures:•Tone selection via an onboard jumper•UL 268 and UL 464 compliant•Pre-wire mounting plate fits various junction box sizes•Fully compatible with existing B501BH-Series sounder baseinstallations•Mechanical locking feature prevents the removal of theattached sensor head InstallationThe B200SR can be mounted directly into a 4” square by atleast 1.5” – 2.1” deep electrical box, using the suppliedmounting kit. B200SR The B200SR sounder base sets a new standard for performance, installation ease, and aesthetics. It offersmaximum flexibility in installation,configuration, and operation to meet or exceed UL 268 and UL 464requirements.For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Intelligent Sounder Base INTELLIKNIGHT ACCESSORY CompatibilityThe B200SR is compatible with the followingSK-series detectors:•SK-Photo Photoelectric Smoke Detector andSK--Photo-T Photoelectric Smoke Detectorwith Thermal• SK-Acclimate Multicriteria PhotoelectricSmoke Detector•SK-Ion Ionization Smoke Detector• SK-Heat Fixed Temperature Thermal Detector,SK -Heat-ROR Rate-of-Rise Detector withThermal, and SK-Heat-HT Fixed HighTemperature Thermal Detector The B200SR is compatible with the followingIntelliKnight FACP’s:570058085820XL B200SR INTELLIKNIGHT ACCESSORY Model B200SRIntelligent Sounder Base MADE IN AMERICA FORM# 350267 Rev A©2010 Honeywell International Inc. This document is not intended to be used for installation purposes. We try tokeep our product information up-to-date and accurate. We cannot cover allspecific applications or anticipate all requirements. All specifications aresubject to change without notice. For more information, contact Silent Knight12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103,Fax: (203) 484-7118. www.silentknight.com SpecificationsPhysicalHeight: 2.0” (5.08 cm) less sensorWidth: 6.875” (17.46 cm)Shipping Weight: 0.50 lb. (227 gm)ElectricalExternal Supply Voltage 16 to 33 VDC (VFWR)External Supply Standby Current 500 µA maximumAlarm Current 35 mA maximumSLC Operating Voltage 15 to 32 VDCSLC Standby Current 300 µA maximumEnvironmentalOperating Temperature: 32ºF – 120ºF (0ºC – 49ºC)Humidity: 10% – 93% non-condensingSound OutputGreater than 85 dBA minimum measured in a UL reverberant room at 10 feet, 24 Volts (in continuous tone)Ordering InformationB200SR Intelligent Sounder Base Agency Listings CO1224T Carbon Monoxide Detector with RealTest™ Technology The System Sensor CO1224T CO detector provides early warning by using electrochemical sensing technology to measure carbon monoxide levels in the air. Features RealTest• ™ technology allows installer to test detector with CO gas Full compliance with UL 2075• A code required trouble relay• Wiring supervision with SEMS terminals• A six year end-of-life timer• 12/24 VDC• A current draw of 20mA in standby and 40mA in alarm• Versatile mounting for wall and ceiling• Electrochemical sensing technology• With RealTest™ technology, the CO gas sensing cell of the CO1224T CO detector can be tested using a carbon monoxide gas agent. Simply hold the test button for two seconds. After the alarm cycle (temp 4) the green LED will flash about once per second, indicating that the detector is ready to accept CO for testing. Spray a small amount of CO into the detector per the installation instructions, and within seconds the detector will alarm, indicating successful gas entry. If dangerous amounts of carbon monoxide is detected, the CO1224T detector will alert residents by sounding and flashing a temp-4 signal alarm. Protection is guaranteed 24/7 by a central station, regardless of whether residents are away from home, sleeping or already suffering from the effects of CO. This specific device is designed for system operation. The detector is fully listed to UL 2075. It offers a code required trouble relay to send a sensor failure or end-of-life signal to the control panel and the central station. It also uses SEMS-type terminal Philips head screws to provide a quicker and more positive wiring connection and code required wiring supervision. The CO1224T detector offers a low current draw, allowing more devices to be connected to the panel without having to purchase a more expensive panel or an extra power supply. The CO1224T model will operate on most industry security and fire alarm control panels because it is is a 12/24 VDC detector. 2075 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2008 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet.A05-0437-000 • 8/08 • #1953 Ordering Information Part No.Description CO1224T 12/24 volt, 4-wire system-monitored carbon monoxide detector with RealTest™ Technology CO1224T Carbon Monoxide Detector Specifications Architectural/Engineering Specifications Carbon monoxide detector shall be a System Sensor model number CO1224T, listed to Underwriters Laboratories UL 2075 for Gas and Vapor Detectors and Sensors. The detector shall be equipped with a sounder and a trouble relay. The detector’s base shall be able to mount to a single-gang electrical box or direct (surface) mount to the wall or ceiling. Wiring connections shall be made by means of SEMS screws. The detector shall provide dual color LED indication, which blinks to indicate normal standby, alarm, or end-of-life. When the sensor supervision is in a trouble condition, the detector shall send a trouble signal to the panel. When the detector gives a trouble or end-of-life signal, the detector shall be replaced. The detector shall provide a means to test CO gas entry into the CO sensing cell. The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry. Electrical Specifications Operating Voltage 12/24 VDC Audible Signal 85 dB in alarm Standby Current 20 mA Alarm Current 40 mA (75 mA test) Alarm Contact Ratings 0.5 A @ 30 VDC Trouble Contact Ratings 0.5 A @ 30 VDC Physical Specifications Size Length: 5.1 in, Width: 3.3 in, Height: 1.3 in Approximate Weight 7 oz Operating Temperature Range 32°F to 104° F (0°C to 40° C) Operating Humidity Range 22 to 90% RH Input Terminals 14 to 22 AWG Mounting Single-gang back box; surface mount to wall or ceiling Operation Modes Operation Mode Green LED Red LED Sounder Normal (standby)Blink 1 per minute —— Alarm —Blink in temp 4 pattern Sound in temp 4 pattern RealTest™ Feature: The System Sensor CO1224T carbon monoxide detector with RealTest™ can evaluate the functionality of the CO sensing cell using canned test agent. NOTE: Check with local codes and the AHJ to determine whether or not a functional gas test is desired for an installation. Hush Feature: Pushing the Test/Hush button will silence the sounder for 5 minutes (except in RealTest mode). Trouble Feature: When the detector is in a trouble condition, it will send a trouble signal to the panel. End-of-life Timer: After the detector’s internal sensor has reached the end of its life, a trouble signal will be sent to the panel. This will indicate that it is time to replace the detector. An electrochemical carbon monoxide detector lifespan is approximately six years, and the detector must be replaced by the date marked on the inside of the product. 1.2.3. Push and hold the Test/Hush button for two seconds to enter RealTest mode. The green LED will flash once every second to indicate RealTest mode has started. Spray canned CO agent into the detector. Verify CO sensing at the control panel. The detector will automatically exit RealTest alarm mode after about 20-60 seconds. DescriptionThe SK-Minimon is an addressablemonitor modules for use with theIntelliKnight fire alarm controlpanels (FACPs). The SK-Minimonactsas an interface to contactdevices, such as waterflowswitches and pull stations.The SK-Minimon supports Class Bsupervised wiring to the loaddevice. Conventional 4-wire smokedetectors can be monitored foralarm and trouble conditionsThe SK-Minimon can be mountedin a single gang junction boxdirectly behind the monitoreddevice. Its small size and lightweight allow it to be installedwithout rigid mountingrequirements.Features•Single contact monitor•SK-Minimon support for Class B(Style B) contact monitor wiring•Small and lightweight size allowsfor flexible mounting options• Rotary address switches for fastinstallation• UL listed SpecificationsElectrical Standby Current: 400 uA max @24 VDC with comm.Voltage Range: 15 - 32 VDCEnd of Line Resistance: 47 k OhmsPhysicalDimensions:2.75” W x 1.3" H x 0.5" DWeight: 1.2 oz (37 g)EnvironmentalOperating Temperature:32ºF – 120ºF (0ºC – 49ºC)Humidity: 10% – 93% non-condensing CompatibilityThe SK-Minimon is compatible withthe following IntelliKnight Systems:5820XL580857005600 (Rev 2.0 or higher)SK-FFT ApprovalsUL approved CSFM FM Approved SK-Minimon The SK-Minimon addressable mini monitor modules for use with Silent Knight IntelliKnight fire alarm controlpanels (FACP). The SK-Minimon is designed to be used with pull stations, water flow switches, and otherapplications requiring dry contact alarm initiation devices. For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103. Intelligent Mini Monitor Module INTELLIKNIGHT ACCESSORY SK-Minimon INTELLIKNIGHT ACCESSORY MADE IN AMERICAFORM# 350133 Rev C©2011 Honeywell International Inc This document is not intended to be used for installation purposes. Wetry to keep our product information up-to-date and accurate. We cannotcover all specific applications or anticipate all requirements. Allspecifications are subject to change without notice. For more information,contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610Phone: (800) 328-0103, Fax: (203)484-7118. www.silentknight.com SK-Minimon Intelligent Monitor Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable monitor modules Silent KnightSK-Minimon. The modules shall be UL listed and compatible with Silent Knight's IntelliKnight FACPs. The deviceshall be capable of Styles A and B supervised wiring to the load device.The SK-Minimon shall be installed inside a single gang junction box directly behind the monitored unit.