HomeMy WebLinkAboutE17-0183 Drawings10.pdf so.VI OF ko .r4o lo zfa IV 09/12/17 ELECTRICAL LEGEND 1 2 3 CABLE/CONDUIT SCHEDULE PANEL SCHEDULE \14SELECTOR SWITCH,ROTARY TYPE O MOTOR PANEL L X DENOTES CONTACT CLOSURE I X00 DEVELOPEMENT AS RELATED TO SWITCH POSITION MARK CONDUCTORS GROUND CONDUIT MARK CONDUCTORS GROUND CONDUIT CIRCUIT BREAKER LOAD LOAD PHASE LOAD LOAD BREAKER CIRCUIT "., 123 W/R/NG RUN EXPOSED l 3-NO. 12,D3/4"C NUMBER TRIP DESCRIPTION VA VA DESCRIPTION TRIP NUMBER J UNLESS NOTED OR 10 2-NO. 12 1-NO. 12 3/4" 40 2-N0. 14 1-N0. 14 3/4" WIRING RUN CONCEALED SCHEDULE 11 3-NO. 12 1-NO. 12 3/4" 41 3-NO 14 1-NO. 14 3/4" 1 20/1 SPARE 100 A 360 RECEPTACLES 20/1 2 CONTROL DEVICE CONTACTS'-N0.NC -E- UNDERGROUND ELECTRICAL 12 4-NO. 12 I-N0. 12 3/4" 42 4-NO 14 I-N0. 14 3/4" 3 ZO/I CONTROLS 300 B 200 SPARE 10/1 4 -0- GROUND GRID 5 100/2 MAIN(KICK FEED) A SOD 20/2 6 13 2-NO JO 1-NO. 10 3/4" 43 6-NO 14 1-N0. 14 3/" ] 1 B 1 1 8 ELECTROMECHANICAL DEVICE COIL 14 3-NO. 10 f-NO 10 3/4" 44 8-NO 14 1-NO. 14 3/4" 1 yyam�(( \/`N/ POWER TRANSFORMER 15 4-N0. 10 I-NO. 10 3/4" 45 f0-NO. 14 1-NO. 14 3/4" (R) PUSH TO TEST TRANSFORMER TYPE PILOT LIGHT AMPS 140 A PHASE CONNECTED VA 560 NEIN 100/2 CKT.BREAKER 77����CC AtA 16 2-NO 8 1-N0. 10 3/4" 46 12-NO. 14 1-NO. 14 1 VOLTAGE 140/110 6 PHASE CONNECTED VA 500 NEUTRAL -I- 17 17 3-N0.8 I-N0. 10 3/4" 47 16-N0. 14 I-NO. 14 I" PH/WIRE 1/3 0 ENCLOSURE NEMA 3R - EARTH GROUNDING CONNECTION 18 4-NO.8 I-NO.8 1 48 20-NO 14 1-NO. 14 1 1/2" SH CKT. 22 KA1C "' TOTAL CONNECTED VA 1060 MOUNTING PEDESTAL FUSE CPT - CPT=CONTROL POWER TRANSFORMER GROUNDED WYE WINDING CONNECTION 19 2-NO 6 I-NO.8 >" 49 24-N0. 14 1-N0. 14 1 1/2" TYPE PLUG ON LOAD CTR. DEMAND VA 1160 MEGA? M/LBANK/EATON 120V 20 3-NO.6 I-N0.8 I" 50 30-NO. 14 I-N0. 14 2" 11 4-NO.6 1-N0.8 1 1/4 51 36-NO. 14 1-NO. 14 2" CONNECTED DEMAND DEMAND PHASE LOADING AO B/ C�O/ LIMIT SWITCH XX MOTOR STARTER WITH OVERLOADS NON-CONDNUOUS LOAD VA FACTOR VA VA VA 22 3-NO.4 1-NO.8 1 1/4" 52 40-NO. 14 1-NO. 14 2" X=CONTACTOR NEMA SIZE CONTROLS 300 1.00 300 560 500ti����O Z-UNIT MOUNTED PILOT DEVICE ((((�1111 23 4-N0.4 1-NO.8 1 1/4" 53 48-NO. 14 1-N0. 14 2" LIGHTING 0 1.25 0 r TEMPERATURE SWITCH A=RED/GREEN LIGHTS 24 3-N0.2 1-N0.6 1 1/2" 54 RECEPTACLES 360 1.00 360 PHASE BALANCE A-B B-6 DIGIT RUN TIME METER SUBTOTAL 660 660 DON C=HAND-OFF-AUTO SWITCH 15 4-NO.2 I-N0.6 1 1/2" 55 15/3 D=OFF-RUN SWITCH 26 56 MOTOR LOAD MLN ACTUAL 7,WP LIGHTING SWITCH RVSS=REDUCED VOLTAGE SOLID STATE 27 57 LARGEST 0 1.25 0 WP=WEATHERPROOF PANEL AMPAC/TY 5 100 =SWITCHED FIXTURE REFERENCE AIR CIRCUIT BREAKER ° 18 5g REMAINDER 0 1.00 0 OVLOTCURRENT DEVICE 5 100 AMPS/POLES T9 59 SUBTOTAL 0 0 Q JUNCTION BOX TM=THERMAL MAGNETIC NOTES' MCP-MOTOR CIRCUIT PROTECTOR 30 1-NO 8 3/4" 70 1-2L/1015 3/4" CONBNUOILS LOAD SPD 1. SPO SINGLE SPLIT PHASE 240/120 VOLTS WP [Ti DENOTES FIELD MOUNTED EOUIPMENT 31 I-N0.6 3/4" 71 2-2C TBTS 3/4" FUTURE 400 1.25 000 ENCLOSED,UL 1449 THIRD EDITION EATON SURGE PROTECTIVE DEVICE 32 1-N0.4 3/4" 72 3-2C/1015 3/4' SUBTOTAL 400 600 EQUIVALENT 8Y PANEL (E] DENOTES EXISTING MANUFACTURER. TURER. - 33 1-NO.2 3/4" 73 4-2C/>BIS 3/4` TOTALS VA 1060 1160 2. LOAD CENTER SHALL BE UL LISTED SERVICE N4 -EEO- FUSE,RATING AND TYPE SHOWN 34 1-N0. 1/0 1" 74 5-2C/1015 1 AMPS 4 5 ENTRANCE EQUIPMENT ID MANUAL MOTOR STARTER 35 1-NO.2/0 1" 75 6-2C/187S 1 1/4" N4=NEMA ENCLOSURE CLASS 36 1-NO.3/0 1 1/4" 76 7-2C/MRS 1 1/2" O UTILITY METER ]] 1-3C FIBTs 3/4 LP BRANCH CIRCUIT DESIGNATION 78 6-3C/18TH f 1/2' 2 LP=PANEL lD,2=CKT NUMBER Fin SHORTING TERMINAL BOX S 79 MNJUF CABLE 3/4` Q DUPLEX GROUNDED RECEPTACLE NOTES' WP=WEATHERPROOF CT CURRENT TRANSFORMER 1.CK DENOTES COMMON CONDUIT(INCREASE CONDUIT SIZE IF REQUIRED). 2 CONDUIT SIZES MAY VARY IN DUCT BANKS R 3 CABLE/CONDUIT SCHEDULE CONTAINS STANDARD INFORMATION,ALL MARKS MAT NOT BE USED. NOTES: 1. THIS LEGEND CONTAINS STANDARD INFORMATION ALL REFERENCES MAY NOT APPLY TO THIS PROJECT E€P y€ Revision Dale By lob No. 2002169.072 1 RSE Eagle River W&S District I RELEASE FOR BID 9/25/2615 RLS Drawn by: CBD E2 Bid Set 4 �� Project onvers Vail Solar Cion Pro Legend and Schedules Out. 8731/2015 118 west Sixth Street,Suite 200 I RUSS SASAADRA ENGINEERINGGlenwood Springs,CO 81601C: R61': W5 d LITTLETON.COLORADO 970.945.1004 Vail,COC� 9 of °% www.sgmne.<om fele: sdog.m.d el ab Erz al