HomeMy WebLinkAboutE17-0183_Vail Tank 3 E1.pdf z 4. HCE "'.)11707.0 ..ii . ." g -... ,.,;. 0,40v,sti or„ .,,, PR/MARY BASE SITE TANK 3 SITE 09/12/17 1-PULL-1 1-PULL-1 i ; BOX 1 1 BOX 1 ' < - 24.9Y/14.4KV �1- - � 1_1_ - _1 HCE 500 KVA PADMOUNT 30, 4W NEMA 4 TRANSFORMER AAA 2.8%z ENCLOSURE I SOLAR [E] [E] < _ 480/277V HOFFMAN CONCEPT 4. X - - - - - - - - - - 1 / GROUND FAULT PANEL 0 0 I ,, ti 21.4 KA I TEST/ II i I - - - - ASSUMED RE ET DEMO COLLECTORS, O MAX FAULT I _ / RETAIN MAST & / — — — — — — 20/2 I ANTENNA ,. MDS 2 1.. TM 1 1 METER - - I CTC GF/ + 1 HCE / I I EXTEND STRUT RACK +`s I �r DISTRIBUTION - - & MOUNT POWER F" ` ili CT TERMINALS 1.OA „..:t I 60/2 48OV PANEL t `I z i �r �� rI yO 3 100VA - / CENTER & MDS 2 ,F .� rr 1 , CPT 1 I WV 5 KVA 1 Al f ,• 4 -.-: ('-'z' ' ' - - 480V 120V• 1 - 20/2 1 I /n\� 10, 3W 1 U 4 4.. • 3� • 1 I GND - CLASS RK5 1 —•— GND 240/120V CT CAB/NET I GND QTY.A2 I �~ - TD GND PER HCE 1r REQUIREMENTS = I I - * L _ _ - - - - - - - - 1 1 I • - 0 —E )20/2 0 NN I r d r . ti) MDS5 ° DISTRIBUTION I €� SPD TERMINALS ,� = .•_ 5OKA . - , . E In , p �� - 3 I I 1 PANEL L 0 • I( s I 60/2 - I 1 AP ; '� GND CLASS I • (� :, •�sM: U 1 �'1.t ,�* , y C RK5 - 1 - - - - `-Y WP Fr 4 - TD / ® SEE NOTE 1 GFI ,� , • 60/2 I ON PANEL L ►:,. I : ;: NEUT i SPD • t , • 1 1 SCHEDULE CABLE/CONDUIT MARK *,, �+ _ , F` L : ..r • SEE SCHEDULE ON E2 TYP. %. ...AC.. �, 2 ,-.r '�- L N ® GROUND W 0 ROD O v 60” Lu W TANK 3 RTU DETAIL 3/4" x 10' GROUND I I I ROD o� POWER ONE—LINE DIAGRAM CT CABINET0 MDS CEDAR 6" BOARDS AS ROUGH EWN REQUIRED FOR EQUIPMENT _ SUPPORT ATTACH WITH _ _ HCE SS LAG BOLTS METER GROUND FAULT PANEL FLAG NOTES: co BURIED POLYMER CONCRETE PULL BOX: NOMINAL 24" x 13" x 15" DEEP, OPEN BOTTOM, BOL TED6" x 6" ROUGH COVER WITH 'ELECTRIC" LOGO, OLD CASTLE CARSON H1324-15 WITH H1324-PI COVER, OR HEWN CEDAR POSTS EQUIVALENT BY HUBBELL QUAZ/TE. PROVIDE 6" GRAVEL UNDERDRAIN. ' - �I i 1YP N UNITIZED POWER CENTER: ENCAPSULATED TRANSFORMER 480:240/120 VOLTS, 5 KVA SINGLE PHASE, ,, 12 CIRCUIT SECONDARY LOAD CENTER, MAIN PRIMARY CIRCUIT BREAKER, U.L. LISTED, EATON co P48G 11 S05P OR EQUIVALENT FORM CONCRETE MIN. 2" o MDS: HEAVY DUTY FUSED SHUNT TRIP SAFETY SWITCH, NEMA 4 STAINLESS STEEL ENCLOSURE, 120 ABOVE GRADE. PROVIDE Lo VOLT TRIP COIL, 600 VOLTS, 60 AMPS, 3 POLE, 4 WIRE CLASS R FUSE CLIPS, SERVICE ENTRANCE POSITIVE DRAINAGE AWAY o RATED AND LABELED, EATON STS262NW31. FROM PIERS N 4 DEMO AND SALVAGE SOLAR COLLECTOR, BATTERIES, AND AUXILIARY EQUIPMENT TRANSPORT `\' SALVAGE EQUIPMENT TO STORAGE AS DIRECTED BY OWNER. PROVIDE SU/TABLE POWER SUPPLY TO \�, \// / / / \ \<//K �\ / )(,/,\ A\/ AN EQUIPMENTiz, CONVERT AC INCOMING PROTECTOR, EATOER TO DC N FAZ DISCONNECTS)INSIDE RTUDFOR RTU ENCLOSURE.OPERATION. PROVIDE _A \ �i/ /�/i�//%/j�%� j* I CABLE-IN-CONDUIT: (3)-NO. 6 COPPER THHN IN 1 " SCH 40 HDPE U.L. LISTED CONDUIT + 4 f "' BLACK-RED-GREEN COLOR CODED INSULATION, SOUTHWIRE SIMPULL 63233899 OR EQUIVALENT Z , -` / C FAN OUT CONDUCTORS IN PULL BOX AND EXTEND IN 1" RGS CONDUIT TO TERMINAL DEVICES. fI TOTAL RUN SHALL BE INSTALLED WITHOUT INTERMEDIATE SPLICES. N f MDS 2: HEAVY DUTY FUSED SAFETY SWITCH, NEMA 4 STAINLESS STEEL ENCLOSURE, PROVISION FOR 4' co PADLOCKS IN BOTH ON AND OFF POSITIONS, 600 VOLTS, 60 AMPS, 3 POLE, 3 WIRE CLASS R FUSE / 12" DIAMETER o CLIPS, EATON DH362FWK OR EQUIVALENT BY SQUARE D OR SIEMENS. ., f r f CONCRETE PIER o TYPICAL AT EACH END / GFI.• GROUND FAULT MONITOR WITH OUTPUT RELAY, EATON D64RP18. / O f x f_ co CPT CONTROL POWER TRANSFORMER, EATON C-0100-E2C FUSES UL CLASS CC TIME DELAY, 200KAIC, 600 VOLTS, BUSSMANN FNQ-R FUSE HOLDERS, UL CLASS CC, INDICATING TYPE, o EATON CHC. N SERVICE MOUNTING STAND DETAIL NO SCALE 0 # Revision Date By Job No. 2002 169.087 Eagle River W&S District Drawn by: CBD E 1 ? 4 RSE Vail Tank 3 1 18 West Sixth Street, Suite 200 Vail Solar Conversion Project Date: 6/29/2017 2 RUSS SASAKURA ENGINEERING Glenwood Springs, CO 81601Electrical QC: RJS PE: RJS of ____ o LITTLETON, COLORADO 970.945. 1004 www.sgm-inc.com Vail, CO File: Vail Tank 3 i