Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A14-0036 Cut Sheets.pdf
DN-7070:K • 12/20/2013 — Page 1 of 8 NFS2-3030 Intelligent Addressable Fire Alarm System Intelligent Fire Alarm Control Panels DN-7070:K • A-10 NFS2-3030 (left) and NFS2-3030 with DVC audio option (right) 7070covg.jpg General The NFS2-3030 is an intelligent Fire Alarm Control Panel (FACP) designed for medium- to large-scale facilities. Fire emergency detection and evacuation are extremely critical to life safety, and the NFS2-3030 is ideally suited for these appli- cations. The NFS2-3030 is part of the ONYX® Series of prod- ucts from NOTIFIER. The NFS2-3030 is ideal for virtually any application because it features a modular design that is config- ured per project requirements. With one to ten Signaling Line Circuits (SLCs), the NFS2-3030 supports up to 3,180 intelli- gent addressable devices. Information is critical to fire evacuation personnel, and the NFS2-3030’s large 640-character Liquid Crystal Display (LCD) presents vital information to operators concerning a fire situa- tion, fire progression, and evacuation details. A host of other options are available, including single- or multi- channel voice; firefighter’s telephone; LED, LCD, or PC-based graphic annunciators; networking; advanced detection prod- ucts for challenging environments, and many additional options. Features • Certified for seismic applications when used with the appro- priate seismic mounting kit. • Approved for Marine applications when a marine-listed ver- sion is used with marine-listed compatible equipment. See DN-60688. • Complies with UL 2572 Mass Notification Systems (NFS2- 3030 version 20 or higher) • One to ten isolated intelligent Signaling Line Circuits (SLC) Style 4, 6 or 7. • Up to 159 detectors and 159 modules per SLC, 318 devices per loop/3,180 per FACP or network node. Detectors can be any mix of ion, photo, laser photo, thermal, or multi-sensor detectors; modules can be addressable pull stations, nor- mally open contact devices, two-wire smoke detectors, notification, or relay modules. • Large 640-character LCD backlit display (16 lines x 40 char- acters) or display-less (a node on a network). • Network options: –High-speed network for up to 200 nodes (NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYXWorks, NFS-3030, NFS-640, and NCA). –Standard network for up to 103 nodes (NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYXWorks, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP-300/400, AFP-1010, and AM2020). Up to 54 nodes when DVC-EM is used in network paging. • Built-in Alarm, Trouble, Security, and Supervisory relays. • VeriFire® Tools online/offline program option. • With built-in Degraded Mode operation, the system is capa- ble of general alarm if a fire alarm condition is present even if the central processing unit (CPU) fails. • Weekly Occupancy Schedules allow changing sensitivity by time of day and day of week. • EIA-485 annunciators, including custom graphics. • History file with 4000-event capacity in nonvolatile memory, plus separate 1000-event alarm-only file. • Advanced history filters allow sorting by event, time, date, or address. • Alarm Verification selection per point, with automatic counter. • Autoprogramming and Walk Test reports. • Multiple central station communication options: –Standard UDACT –Internet –Internet/GSM • Positive Alarm Sequence (PAS) Presignal. • Silence Inhibit and Auto Silence timer options. • Field-programmable on panel or on PC, with VeriFire Tools program, also check, compare. • Non-alarm points for lower priority functions. • Remote ACK/Signal Silence/System Reset/Drill via monitor modules. • Up to 1000 powerful Boolean logic equations. • Supports SCS Series smoke control system in both HVAC and FSCS modes. • FM6320 approved Gas Detection System with FMM-4-20 module and any FM listed gas detector. • EIA-232 printer port. • EIA-485 annunciator port. 640-CHARACTER DISPLAY FEATURES • Backlit, 640-character display. • Program keypad: full QWERTY keypad. • Up to nine users, each with a password and selectable access levels. Page 2 of 8 — DN-7070:K • 12/20/2013 •11 LED indicators: Power; Fire Alarm; Pre-Alarm; Secu- rity; Supervisory; System Trouble; Other Event; Signals Silenced; Point Disabled; CPU Failure; Controls Active. •Membrane Switch Controls: Acknowledge; Signal Silence; Drill; System Reset; Lamp Test. •LCD Display: 640 characters (16 lines x 40 characters) with long-life LED backlight. FLASHSCAN® INTELLIGENT FEATURES • Polls up to 318 devices on each loop in less than two seconds. • Activates up to 159 outputs in less than five seconds. • Multicolor LEDs blink device address during Walk Test. • Fully digital, high-precision protocol (U.S. Patent 5,539,389). • Manual sensitivity adjustment — up to nine levels. • Pre-alarm ONYX intelligent sensing — up to nine levels. • Sensitivity levels: –Ion – 0.5 to 2.5%/foot obscuration. –Photo – 0.5 to 2.35%/foot obscuration. – Laser (VIEW®) – 0.02 to 2.0%/foot obscuration. – Acclimate Plus™ – 0.5 to 4.0%/foot obscuration. – IntelliQuad – 1.0 to 4.0%/foot obscuration. – IntelliQuad™ PLUS – 1.0 to 4.0%/foot obscuration • Drift compensation (U.S. Patent 5,764,142). • Multi-detector algorithm involves nearby detectors in alarm decision (U.S. Patent 5,627,515). • Automatic detector sensitivity testing (NFPA-72 compliant). • Maintenance alert (two levels). • Self-optimizing pre-alarm. • Programmable activation of sounder/relay bases during alarm or pre-alarm. • Read Status displays the level of detector cleanliness. FSL-751 VIEW® (VERY INTELLIGENT EARLY WARNING) SMOKE DETECTION TECHNOLOGY • Advanced ONYX intelligent sensing algorithms differentiate between smoke and non-smoke signals (U.S. Patent 5,831,524). • Addressable operation pinpoints the fire location. • Early warning performance comparable to the best aspira- tion systems at a fraction of the lifetime cost. FAPT-851 ACCLIMATE PLUS™ LOW-PROFILE INTELLIGENT MULTI-SENSOR • Detector automatically adjusts sensitivity levels without operator intervention or programming. Sensitivity increases with heat. • Microprocessor-based technology; combination photo and thermal technology. • Low-temperature signal at 40°F ± 5°F (4.44°C ± 2.77°C). FSC-851 INTELLIQUAD ADVANCED MULTI-CRITERIA DETECTOR • Detects all four major elements of a fire (smoke, heat, CO, and flame). • Automatic drift compensation of smoke sensor and CO cell. FRM-1 Relay Contact NOTE: CPU2-3030 firmware version 14.0 (and higher) can support LCD-160 on the RDP port, or LCD2-80 in terminal mode, but not both at the same time. CPU2-3030D display or CPU2-3030ND PRN Series Printer NFS2-3030 Sample System Options FAPT-851 FSL-751 FSP-851 FSA-8000...etc. Shown in CAB-C4 with display DVC-EM audio in CA-1 in second tier7070blok-2013.wmfLCD-160LCD2-80 Up to 32 remote displays EIA-485 EIA-485 SLC Intelligent Loop 3072 annunciator/control points Optional 2048-point UDACT Dual phone lines to Central StationEIA-232 DEVICES ACM/AEM-24AT LED Annunciator LDM-32 Custom Graphics ACM-8R Relay Control NBG-12LX XP6/10 I/O Modules FMM-1IDC DN-7070:K • 12/20/2013 — Page 3 of 8 • High nuisance-alarm immunity. FSA-8000 INTELLIGENT FAAST DETECTOR • Connects directly to the SLC loop of compatible ONYX series panels • Provides five event thresholds that can be individually pro- grammed with descriptive labels for control-by-event pro- gramming; uses five detector addresses. • Uses patented particle separator and field-replaceable filter to remove contaminants. • Advanced algorithms reject common nuisance conditions FCO-851 INTELLIQUAD™ PLUS ADVANCED MULTI-CRITERIA FIRE/CO DETECTOR • Detects all four major elements of a fire. • Separate signal for life-safety CO detection. • Optional addressable sounder base for Temp-3 (fire) or Temp-4(CO) tone. • Automatic drift compensation of smoke sensor and CO cell. • High nuisance-alarm immunity. FMM-4-20 GAS DETECTION MODULE • Interface to industry-standard linear scale 4-20 mA sensors. • Five programmable thresholds. • FM Approved, Class 6320 (Stationary Gas Sensors/ Detectors). RELEASING FEATURES • Ten independent hazards. • Sophisticated cross-zone (three options). • Delay timer and Discharge timers (adjustable). • Abort (four options). VOICE AND TELEPHONE FEATURES • Up to eight channels of digital audio. • 35 watt, 50 watt, 75 watt, and 100/125 watt digital amplifiers (DAA2/DAX series and DS series). • Solid state message generation. • Hard-wired voice control module options. • Firefighter telephone option. • 30- to 120-watt analog amplifiers (AA Series). • Backup tone generator and amplifier option. FlashScan® Exclusive World-Leading Detector Protocol At the heart of the NFS2-3030 is a set of detection devices and device protocol — FlashScan (U.S. Patent 5,539,389). FlashS- can is an all-digital protocol that gives superior precision and high noise immunity. As well as giving quick identification of an active input device, this protocol can also activate many output devices in a frac- tion of the time required by competitive protocols. This high speed also allows the NFS2-3030 to have the largest device per loop capacity in the industry — 318 points — yet every input and output device is sampled in less than two seconds. The microprocessor-based FlashScan® detectors have bicolor LEDs that can be coded to provide diagnostic information, such as device address during Walk Test. ONYX Intelligent Sensing ONYX Intelligent Sensing is a set of software algorithms that provide the NFS2-3030 with industry-leading smoke detection capability. These complex algorithms require many calcula- tions on each reading of each detector, and are made possible by the very high-speed microcomputer used by the NFS2- 3030. Drift Compensation and Smoothing. Drift compensation allows the detector to retain its original ability to detect actual smoke, and resist false alarms, even as dirt accumulates. It reduces maintenance requirements by allowing the system to automatically perform the periodic sensitivity measurements required by NFPA 72. Smoothing filters are also provided by software to remove transient noise signals, usually caused by electrical interference. Maintenance Warnings. When the drift compensation per- formed for a detector reaches a certain level, the performance of the detector may be compromised, and special warnings are given. There are three warning levels: (1) Low Chamber value; (2) Maintenance Alert, indicative of dust accumulation that is near but below the allowed limit; (3) Maintenance Urgent, indicative of dust accumulation above the allowed limit. Sensitivity Adjust. Nine sensitivity levels are provided for alarm detection. These levels can be set manually, or can change automatically between day and night. Nine levels of pre-alarm sensitivity can also be selected, based on predeter- mined levels of alarm. Pre-alarm operation can be latching or self-restoring, and can be used to activate special control func- tions. Self-Optimizing Pre-Alarm. Each detector may be set for “Self-Optimizing” pre-alarm. In this special mode, the detector “learns” its normal environment, measuring the peak analog readings over a long period of time, and setting the pre-alarm level just above these normal peaks. Cooperating Multi-Detector Sensing. A patented feature of ONYX Intelligent Sensing is the ability of a smoke sensor to consider readings from nearby sensors in making alarm or pre-alarm decisions. Without statistical sacrifice in the ability to resist false alarms, it allows a sensor to increase its sensitivity to actual smoke by a factor of almost two to one. Field Programming Options Autoprogram is a timesaving feature. The FACP “learns” what devices are physically connected and automatically loads them in the program with default values for all parameters. Requiring less than one minute to run, this routine allows the user to have almost immediate fire protection in a new installa- tion, even if only a portion of the detectors are installed. Keypad Program Edit. The NFS2-3030, like all NOTIFIER intelligent panels, has the exclusive feature of program cre- ation and editing capability from the front panel keypad, while continuing to provide fire protection. The architecture of the NFS2-3030 software is such that each point entry carries its own program, including control-by-event links to other points. This allows the program to be entered with independent per- point segments, while the NFS2-3030 simultaneously monitors other (already installed) points for alarm conditions. VERIFIRE® TOOLS VeriFire® Tools is an offline programming and test utility that can greatly reduce installation programming time, and increase confidence in the site-specific software. It is Win- dows® based and provides technologically advanced capabili- ties to aid the installer. The installer may create the entire program for the NFS2-3030 in the comfort of the office, test it, store a backup file, then bring it to the site and download from a laptop into the panel. Page 4 of 8 — DN-7070:K • 12/20/2013 Product Line Information • “Configuration Guidelines” on page 4 • “Main System Components” on page 4 • “Networking Options” on page 4 • “Auxiliary Power Supplies and Batteries” on page 4 • “Audio Options” on page 4 • “Compatible Devices, EIA-232 Ports” on page 5 • “Compatible Devices, EIA-485 Ports” on page 5 • “Compatible Intelligent Devices” on page 5 • “Enclosures, Chassis, and Dress Plates” on page 6 • “Other Options” on page 7 CONFIGURATION GUIDELINES Stand-alone and network systems require a main display. On single-FACP systems (one NFS2-3030D), the display option is the CPU2-3030D. On network systems (two or more net- worked fire panel nodes), at least one NCA-2, NCS, or ONYX- Works annunciation device is required. Options listed as follows. MAIN SYSTEM COMPONENTS CPU2-3030D: NFS2-3030 Primary Display. CPU2-3030D ships with keypad/display installed; includes 640-character backlit LCD display, QWERTY programming and control key- pad. CPU2-3030 is a central processing unit and requires an AMPS-24(E) power supply. Non-English versions are avail- able: CPU2-3030D-FR, CPU2-3030D-HE, CPU2-3030D-KO, CPU2-3030D-PO, CPU2-3030D-SC, CPU2-3030D-SP, CPU2- 3030D-TC, and CPU2-3030D-TH. For English Marine applica- tions order CPU2-3030D-M; for non-English Marine applica- tions order CPU2-3030D-M and the appropriate KP-KIT-XX. (See DN-60688.) CPU2-3030ND: CPU2-3030 without display. Non-English ver- sions are available: CPU2-3030ND-FR, CPU2-3030ND-HE, CPU2-3030ND-KO, CPU2-3030ND-PO, CPU2-3030ND-SC, CPU2-3030ND-SP, CPU2-3030ND-TC. LCM-320: Loop Control Module. Provides one SLC. NFS2- 3030 supports up to five LCM-320s and five LEM-320 expand- ers for a total of ten SLCs. See DN-6881. LEM-320: Loop Expander Module. Expands an LCM-320. See DN-6881. SAMPLE SYSTEM: Four-loop NFS2-3030 with display: CPU2-3030D, DP-DISP, two BMP-1s, CHS-M3, two LCM- 320s, two LEM-320s, AMPS-24, SBB-A4, DR-A4, BP2-4, BB- 100, batteries. NETWORKING OPTIONS NCA-2: Network Control Annunciator, 640 characters. An alternate primary display for CPU2-3030 can be provided by the NCA-2, NCS, or ONYXWorks. Using NCA-2 as primary display enables non-English languages. On network systems (two or more networked fire panel nodes), one network display (either NCA-2, NCS, or ONYXWorks) is required for every sys- tem. On network systems, the NCA-2 connects (and requires) a standard Network Communication Module or High-Speed Network Communication Module. Mounts in a row of FACP node or in two annunciator positions. Mounting options include the DP-DISP, ADP-4B, or in an annunciator box, such as the ABS-2D. In CAB-4 top-row applications, a DP-DISP and two BMP-1 blank modules are required for mounting. Non-English versions are available: NCA-2-FR, NCA-2-HE, NCA-2-KO, NCA-2-PO, NCA-2-SC, NCA-2-SP, NCA-2-TC, NCA-2-TH. For marine applications, order NCA-2-M; for non-English marine applications order NCA-2-M and appropriate KP-KIT-XX. See DN-7047. NCM-W, NCM-F: Standard Network Communications Mod- ules. Wire and multi-mode fiber versions available. See DN- 6861. HS-NCM-W/MF/SF/WMF/WSF/MFSF: High-speed Network Communications Modules that can connect to two nodes. Wire, single-mode fiber, multi-mode fiber, and media conver- sion models are available. See DN-60454. RPT-W, RPT-F, RPT-WF: Standard-network repeater board with wire connection (RPT-W), multi-mode fiber connection (RPT-F), or allowing a change in media type between wire and fiber (RPT-WF). Not used with high-speed networks. See DN- 6971. ONYXWorks: UL-listed graphics PC workstation, ONYXWorks GUI software, and computer hardware. See DN-7048 for spe- cific part numbers. NFN-GW-EM-3: NFN Gateway, embedded. (Replaces NFN- GW-EM.) See DN-60499. NWS-3: NOTI•FIRE•NET™ Web Server. See DN-6928. CAP-GW: Common Alerting Protocol Gateway. See DN- 60576. VESDA-HLI-GW: VESDAnet high-level interface gateway. See DN-60753. LEDSIGN-GW: UL-listed sign gateway. Interfaces with classic and high-speed NOTI•FIRE•NET networks through the NFN Gateway. See DN-60679. OAX2-24V: UL-listed LED sign, used with LEDSIGN-GW. See DN-60679. AUXILIARY POWER SUPPLIES AND BATTERIES AMPS-24(E): One required for each NFS2-3030. Addressable power supply and battery charger with two 24 VDC outputs. Addressable by any FlashScan® or CLIP mode FACP. Charges 7 to 200 AH batteries. Occupies up to five addresses on an SLC, depending on configuration. Primary input power for panel. See DN-6883. APS2-6R: Auxiliary Power Supply. Provides up to 6.0 amperes of power for peripheral devices. Includes battery input and transfer relay, and overcurrent protection. Mounts on two of four positions on a CHS-4L or CHS-4 chassis. See DN-5952. ACPS-610: 6.0 A or 10.0 A addressable charging power sup- ply. See DN-60244. FCPS-24S6/-24S8: Remote 6 A and 8 A power supplies with battery charger. See DN-6927. BAT Series: Batteries. AMPS-24 uses two 12 volt, 7 to 200 AH batteries. See DN-6933. AUDIO OPTIONS NOTE: See “Enclosures, Chassis, and Dress Plates” on page 6 for mounting hardware. DVC-EM: Digital Voice Command, digital audio processor with message storage for up to 32 minutes of standard quality (4 minutes at high quality) digital audio. See DN-7045. DVC-RPU: Digital Voice Command Remote Paging Unit for use with DVC-EM. Includes the keypad/display. See DN- 60726. DS-DB: Digital Series Distribution Board, provides bulk ampli- fication capabilities to the DVC-EM while retaining digital audio distribuition capabilities. Can be configured with up to four DS- AMPs, supplying high-level risers spread throughout an instal- lation. See DN-60565. DVC-KD: DVC-EM keypad for local annunciation and controls; status LEDs and 24 user-programmable buttons. See DN- 7045. DN-7070:K • 12/20/2013 — Page 5 of 8 DS-AMP/E: 125W, 25 VRMS, or 100W, 70VRMS. 70VRMS requires DS-XF70V step-up transformer. Digital Series Ampli- fier, part of the DS-DB system. See DN-60663. DS-RFM, DS-FM, DS-SFM: Fiber conversion modules for DVC-EM, DS-DB distribution board, and DAA2/DAX Series amplifiers. See DN-60633. DAA2-5025(E): 50W, 25 Vrms Digital Audio Amplifier assem- bly with power supply; includes chassis. See DN-60556. DAA2-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier assembly with power supply; includes chassis. See DN-60556. DAA2-7525(E): 75W, 25 Vrms digital audio amplifier assembly with power supply; includes chassis. See DN-60556. DAX-3525(E): 35W, 25 Vrms Digital Audio Amplifier assembly with power supply, includes chassis. See DN-60561. DAX-3570(E): 35W, 70.7 Vrms Digital Audio Amplifier assem- bly with power supply, includes chassis. See DN-60561. DAX-5025(E): 50W, 25 Vrms Digital Audio Amplifier assembly with power supply, includes chassis. See DN-60561. DAX-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier assem- bly with power supply, includes chassis. See DN-60561. TELH-1: Firefighter’s Telephone Handset for use with the DVC-EM when mounted in the CA-2 chassis. See DN-7045. CMIC-1: Microphone used with DVC/DVC-EM. Included with CA-2 chassis assembly. See DN-7045. RM-1/RM-1SA: Remote microphone assemblies, mount on ADP-4 (RM-1) dress panel or CAB-RM/-RMR (RM-1SA) stand-alone cabinets. See DN-6728. AA-30: Audio Amplifier, 30 watts, 25 Vrms. Includes amplifier and audio input supervision, backup input, and automatic swi- tchover, power supply, cables. See DN-3224. AA-120/AA-100: Audio Amplifier. AA-120 is 120 watts, 25 Vrms. AA-100 is 100 watts, 70.7 Vrms. The amplifier contains an integral chassis for mounting to a CAB-B4, -C4, or -D4 backbox (consumes one row). Includes audio input and ampli- fied output supervision, backup input, and automatic switcho- ver to backup tone. See DN-3224. DAA Series Digital Audio Amplifiers: Legacy DAA Series amplifiers are compatible with DVC systems running SR4.0. For specific information on DAA-50 series amplifiers, refer to DN-7046. For information on DAA-7525 Series, refer to DN- 60257. COMPATIBLE DEVICES, EIA-232 PORTS PRN-6: 80-column printer. See DN-6956. VS4095/5: Printer, 40-column, 24 V. Order from Keltron, Inc. See DN-3260. DPI-232: Direct Panel Interface, specialized modem for extending serial data links to remotely located FACPs and/or peripherals. See DN-6870. COMPATIBLE DEVICES, EIA-485 PORTS ACM-24AT: ONYX® Series ACS annunciator – up to 96 points of annunciation with Alarm or Active LED, Trouble LED, and switch per circuit. Active/Alarm LEDs can be programmed (by powered-up switch selection) by point to be red, green, or yel- low; the Trouble LED is always yellow. See DN-6862. AEM-24AT: Same LED and switch capabilities as ACM-24AT; expands the ACM-24AT to 48, 72, or 96 points. See DN-6862. ACM-48A: ONYX® Series ACS annunciator – up to 96 points of annunciation with Alarm or Active LED per circuit. Active/ Alarm LEDs can be programmed (by powered-up switch selec- tion) in groups of 24 to be red, green, or yellow. Expandable to 96 points with one AEM-48A. See DN-6862. AEM-48A: Same LED capabilities as ACM-48A; expands the ACM-48A to 96 points. See DN-6862. ACM-8R: Remote Relay Module with eight Form-C contacts. Can be located up to 6,000 ft. (1828.8 m) from panel on four wires. See DN-3558. LCD-160: Liquid Crystal Display annunciator, 160-character backlit. Can store character sets for multiple languages. Sup- ports Canadian requirements. See DN-6940. LCD2-80: Terminal and ACS mode. 80-character, backlit LCD display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per FACP. See LCD2-80 (DN-60548). SCS Series: Smoke control station; eight (expandable to 16) circuits. See DN-4818. TM-4: Transmitter Module. Includes three reverse-polarity cir- cuits and one municipal box circuit. Mounts in panel module position (as in single-address mode applications) or in CHS- M3 position. See DN-6860. UDACT-2: Universal Digital Alarm Communicator Transmitter, 636 channel. See DN-60686. UZC-256: Programmable Universal Zone Coder provides pos- itive non-interfering successive zone coding. Microprocessor- controlled, field-programmable from IBM®-compatible PCs (requires optional programming kit). Mounts on a CHS-4 series chassis within NFS2-3030. COMPATIBLE INTELLIGENT DEVICES FSA-8000: Intelligent FAAST Fire Alarm Aspiration Sensing Technology®. Intelligent aspirating smoke detector. For Cana- dian applications, order FSA-8000A. See DN-60792. FSB-200: Intelligent beam smoke detector. See DN-6985. FSB-200S: Intelligent beam smoke detector with integral sen- sitivity test. See DN-6985. FSC-851: FlashScan IntelliQuad Advanced Multi-Criteria Detector. See DN-60412. FCO-851: FlashScan IntelliQuad PLUS Advanced Multi-Crite- ria Fire/CO Detector. See DN-60689. FSI-851: Low-profile FlashScan ionization detector. See DN- 6985. FSP-851: Low-profile FlashScan photoelectric detector. See DN-6935. FSP-851R: Low-profile intelligent photoelectric sensor, remote test capable. For use with DNR(W). See DN-6935. FSP-851T: Low-profile FlashScan photoelectric detector with 135°F (57°C) thermal. See DN-6935. FST-851: FlashScan thermal detector 135°F (57°C). See DN- 6936. FST-851R: FlashScan thermal detector 135°F (57°C) with rate-of-rise. See DN-6936. FST-851H: FlashScan 190°F (88°C) high-temperature thermal detector. See DN-6936. FAPT-851: FlashScan Acclimate Plus™ low-profile multi-sen- sor detector. See DN-6937. FSL-751: FlashScan VIEW® laser photo detector. See DN- 6886. DNR: InnovairFlex low-flow non-relay duct-detector housing (order FSP-851 separately). Replaces FSD-751PL/FSD- 751RPL. See DN-60429. DNRW: Same as above with NEMA-4 rating, watertight. See DN-60429. B224RB: Low-profile relay base. See DN-60054. Page 6 of 8 — DN-7070:K • 12/20/2013 B224BI: Isolator base for low-profile detectors. See DN- 60054. B210LP: Low-profile base. Standard U.S. style. Replaces B710LP. See DN-60054. B501: European-style, 4" (10.16 cm) base. See DN-60054. B200S: Intelligent programmable sounder base, capable of producing a variety of tone patterns including ANSI Temporal 3. Compatible with sychronization protocol. See DN-60054. B200SCOA: Based on B200SA, with added CO detector markings in English/French. For Canadian applications only. B200SR: Sounder base, Temporal 3 or Continuous tone. See DN-60054. FMM-1: FlashScan monitor module. See DN-6720. FDM-1: FlashScan dual monitor module. See DN-6720. FZM-1: FlashScan two-wire detector monitor module. See DN- 6720. FMM-101: FlashScan miniature monitor module. See DN- 6720. FMM-4-20: FlashScan 4-20 mA protocol monitor module. See DN-60411. FCM-1: FlashScan control module. See DN-6724. FCM-1-REL: FlashScan releasing control module. See DN- 60390. FTM-1: Firephone Telephone Module connects a remote fire- fighter telephone to a centralized telephone console. Reports status to panel. Wiring to jacks and handsets is supervised. See DN-6989. FRM-1: FlashScan relay module. See DN-6724. FDRM-1: FlashScan dual monitor/dual relay module. See DN- 60709. NBG-12LX: Manual pull station, addressable. See DN-6726. ISO-X: Isolator module. See DN-2243. XP6-C: FlashScan six-circuit supervised control module. See DN-6924. XP6-MA: FlashScan six-zone interface module; connects intelligent alarm system to two-wire conventional detection zone. See DN-6925. XP6-R: FlashScan six-relay (Form-C) control module. See DN-6926. XP10-M: FlashScan ten-input monitor module. See DN-6923. SLC-IM: SLC integration module, for VESDAnet detectors. See DN-60755. ENCLOSURES, CHASSIS, AND DRESS PLATES CAB-4 Series Enclosure: NFS2-3030 mounts in a standard CAB-4 Series enclosure (available in four sizes, “A” through “D”). Backbox and door ordered separately; requires BP2-4 battery plate. A trim ring option is available for semi-flush mounting. See DN-6857. EQ Series Cabinets: EQ series cabinets will house amplifiers, power supplies, battery chargers and control modules. EQ cabinets are available in three sizes, “B” through “D”. See DN- 60229. CAB-BM Marine System: Protects equipment in shipboard and waterfront applications. Order CPU2-3030D-M; for non- English marine applications order CPU2-3030D and appropri- ate KP-KIT-XX. Also order BB-MB for systems using 100 AH batteries. For a full list of required and optional equipment, see DN-60688. CHS-M3: Mounting chassis for CPU2-3030. One required for each CPU2-3030D/3030ND. CA-2: Chassis for FACP control panel when DVC-EM is used with firefighter's telephone. Mounts in the top two rows of a CAB-4 series enclosure. DP-DISP: Dress panel for top row in cabinet with CPU2- 3030D installed. DP-1B: Blank dress panel. Provides dead-front panel for unused tiers; covers DAA2/DAX series or AA-series amplifier. See DN-7046. CHS-BH1: Battery chassis; holds two 12.0 AH batteries. Mounts on the left side of DAA2 chassis. See DN-7046. CA-1: Chassis, occupies one tier of a CAB-4 Series enclosure. The left side accommodates one DVC-EM and a DVC-KD (optional); and the right side houses a CMIC-1 microphone and its well (optional). See DN-7045. CA-2: Chassis assembly, occupies two tiers of a CAB-4 Series enclosure. The left side accommodates one DVC-EM mounted on a half-chassis and one NFS2-3030 or NCA-2 mounted on a half-chassis. The right side houses a microphone/handset well. The CA-2 assembly includes CMIC-1 microphone. ADDR Series doors with two-tier visibility are available for use with the CA-2 configuration: ADDR-B4, ADDR-C4, ADDR-D4 (below). ADDR-B4: Two-tier-sized door designed for use with the CA-2 chassis configuration. ADDR Series doors are similar to CAB- 4 Series “DR” doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-B4 backbox with the ADDR-B4. See DN-7045, DN-6857. ADDR-C4: Three-tier-sized door designed for use with the CA- 2 chassis configuration. ADDR Series doors are similar to CAB-4 Series “DR” doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-C4 backbox with the ADDR-C4. See DN-7045, DN-6857. ADDR-D4: Four-tier-sized door designed for use with the CA-2 chassis configuration. ADDR Series doors are similar to CAB- 4 Series “DR” doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-D4 backbox with the ADDR-D4. See DN-7045, DN-6857. DPA-1: Dress panel, used with the CA-1 chassis when config- ured with a DVC-EM, DVC-KD, and CMIC-1. See DN-7045. DPA-2: Dress Panel used with the CA-2 chassis assembly. DPA-1A4: Dress panel, used with the CA-1 chassis when the CMIC-1 is not used. Provides mounting options on right two bays for two ACS annunciators, or for blank plates. See DN- 7045. ADP-4B: Annunciator dress plate. Mounts in rows 2, 3 or 4 of a CAB-4 series enclosure. Used with ACS series annuncia- tors. BMP-1: Blank module for unused module positions. DP-1B: Blank dress panel. Provides dead-front panel for unused tiers; covers DAA2/DAX series or AA-series amplifier. BP2-4: Battery plate, required. CHS-4L: Low-profile four-position Chassis. Mounts two AA-30 amplifiers. CHS-4N: Chassis for mounting up to four APS-6Rs. CHS-6: Chassis used with the XP6 and XP10 Multi-Modules. Mounts up to six modules in any CAB-4 series row. BB-100: Backbox for batteries and power supplies. The BB- 100 is used to mount up to two 100 AH batteries and power supply, if needed. 30" (76.20 cm) wide x 25" (63.50 cm) high x 7.5" (19.05 cm) deep; depth includes door. BB-200: Backbox for batteries and power supplies. Holds up to four 100 AH batteries (200 AH capacity) and power supply. DN-7070:K • 12/20/2013 — Page 7 of 8 30" (76.20 cm) wide x 36" (91.44 cm) high x 7.5" (19.05 cm) deep; depth includes door. NFS-LBB: Battery Box. The NFS-LBB is used to mount up to two 55 AH batteries. Dimensions: Box: 24" (610 mm) wide x 14" (356 mm) high x 7.75" (197 mm) deep. Door: 24.125" (613 mm) wide x 14.25" (362 mm) high; door adds 0.0625" (approx. 1.6 mm) to depth. BB-UZC: Backbox for housing the UZC-256 for applications where the UZC will not fit in panel enclosure. Black; for red, order BB-UZC-R. See DN-3404. SEISKIT-CAB: Seismic mounting kit. Required for seismic- certified applications with NFS2-3030 and other equipment mounted in CAB-4 Series Enclosures. Includes battery bracket for two 26 AH batteries. SEISKIT-LBB: Seismic kit for the NFS-LBB. Includes battery bracket for two 55 AH batteries. OTHER OPTIONS 411: Slave digital alarm communicator. See DN-6619. 411UDAC: Digital alarm communicator. See DN-6746. IPDACT-2, IPDACT Internet Monitoring Module: Connects to primary and secondary DACT telephone output ports for internet communications over customer-provided Ethernet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IP. See DN-60408. IPCHSKIT: IP Communicator Chassis Mounting Kit. For mounting an IPDACT-2/2UD onto the panel chassis or CHS-4 series chassis. Use IPENC for external mounting applications. IPSPLT: Y-adapter option allow connection of both panel dialer outputs to one IPDACT-2/2UD cable input. IPENC: External enclosure for IPDACT, includes IPBRKT mounting bracket; Red; for black, order IPENC-B. IPGSM-4G: Internet and Digital Cellular Fire Alarm Communica- tor. Provides selectable configurable paths: cellular only, IP only, or IP primary with cellular backup. Connects to the primary and secondary ports of a DACT. For Canadian applications order IPGSM-4GC. See DH-60769. NOTE: For other options including compatibility with retrofit equip- ment, refer to the panel's installation manual, the SLC manual, and the Device Compatibility Document. System Specifications SYSTEM CAPACITY • Intelligent Signaling Line Circuits ...........1 expandable to 10 • Intelligent detectors ..........................................159 per loop • Addressable monitor/control modules..............159 per loop • Programmable software zones.............................over 2000 • ACS annunciators per CPU2-3030 .......................32 address x 64 or 96 points NOTE: The CPU2-3030 can support up to 96 annunciator address points per ACM-24AT/-48A. SPECIFICATIONS Primary Input Power: –AMPS-24: 110-120 VAC, 50/60 Hz, 4.5 A maximum. –AMPS-24E: 240 VAC, 50/60 Hz, 2.25 A maximum. DC Output: –Main 24 VDC: Up to 5.0 A –Aux 24 VDC: Up to 5.0 A –5 VDC: Up to 0.15 A. Current draw (Standby/Alarm): –CPU2-3030D board: 0.340 A. –CPU2-3030ND board: 0.120 A. –LCM-320: 0.130 A. –LEM-320: 0.100 A. –AMPS-24(E)*: 0.13 A. (Draws power from secondary power source only.) NOTE: See AMPS-24(E) Manual 51907 for a complete current draw calculation sheet and details of input and output values. Battery charger range: 7 AH – 200 AH. Use separate cabinet for batteries over 26 AH. Float Rate: 27.6 V. SHIPPING WEIGHT • CPU2-3030D: 5.95 lb (2.70 kg). • CPU2-3030ND: 2.90 lb (1.32 kg). TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F. AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. •UL Listed: S635. •ULC Listed: S635. •MEA: 232-06-E. •FDNY: COA#6114. •CSFM: 7165-0028:0224 (Commercial). • FM Approved. •FM6320 Approved. Class 6320 for Gas Detection. • City of Chicago. • City of Denver. • Singapore Productivity and Standards Board (PSB). •CCCF listed. • Fire Services Department (Hong Kong). Marine Applications: Marine approved systems must be con- figured using components itemized in this document. (See Main System Components, in “Product Line Information.) Spe- cific connections and requirements for those components are described in the installation document, PN 54756. When these requirements are followed, systems are approved by the fol- lowing agencies: •US Coast Guard 161.002/55/0 (Standard 46 CFR and 161.002). •Lloyd's Register 11/600013 (ENV 3 category). •American Bureau of Shipping (ABS) Type Approval. NOTE: For information on marine applications, see DN-60688. STANDARDS The NFS2-3030 complies with the following UL Standards and NFPA 72, International Building Code (IBC), and California Building Code (CBC) Fire Alarm Systems requirements: •UL 864 (Fire). •UL 1076 (Burglary). •UL 2572 (Mass Notification Systems). Page 8 of 8 — DN-7070:K • 12/20/2013 IntelliQuad™ and NOTI•FIRE•NET™ are all trademarks; and Acclimate® Plus™, FlashScan®, NOTIFIER®, ONYX®, VeriFire®, and VIEW® are all registered trademarks of Honeywell International Inc. ©2013 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Made in the U.S. A. •LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). •AUXILIARY (Automatic, Manual and Waterflow) (requires TM-4). •REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (requires TM-4). •PROPRIETARY (Automatic, Manual, Waterflow and Sprin- kler Supervisory). Not applicable for FM. •EMERGENCY VOICE/ALARM. •OT, PSDN (Other Technologies, Packet-switched Data Net- work). •IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seis- mic). •CBC 2007 (Seismic). DN-60689:B • 12/3/2012 — Page 1 of 2 FCO-851(A) IntelliQuad™ PLUS Advanced Multi-Criteria Fire/CO Detector Intelligent/Addressable Devices DN-60689:B General World-class fire and carbon monoxide (CO) detection com-bined in a single addressable device provides a practical solu- tion for today’s market. The IntelliQuad PLUS FCO-851(A) Advanced Multi-CriteriaFire/CO Detector is a plug-in, addressable device that pro- vides both fire and carbon monoxide (CO) detection. For fire, the detector combines four separate sensing elements in one unit (smoke, CO, light/flame, and heat) to sense multiple com- ponents of a fire. This approach enables enhanced sensitivity to real fire with heightened immunity to nuisance particulate. For CO, the detector’s electrochemical sensing cell creates aseparate signal for life safety CO detection. CO is a colorless, odorless, and deadly gas that is virtually impossible to detect with the human senses. It is releasedwhenever carbon-based fuels (from fossil fuels to firewood) burn without enough oxygen to form CO2. Because the poten- tial exists for dangerous levels of CO to accumulate in almost any building, legislation mandating the use of CO detection in commercial spaces continues to increase across the U.S. and Canada. The FCO-851(A) is listed to the UL 268 standard for smoke detectors and the UL 2075 standard for system-con-nected life safety carbon monoxide monitoring. The FCO-851(A) should be used in conjunction with the B200S(COA) intelligent sounder base, which can generateeither a Temp 3 pattern for fire or a Temp 4 pattern for CO alarm indication. The B200S(COA) recognizes the System Sensor synchroniza- tion protocol. This enables it to be used as a component of the general evacuation signal — along with other System Sensor horns, horn strobes, and chimes — when connected to a power supply or Fire Alarm Control Panel (FACP) output capa-ble of generating the System Sensor synchronization pulses. With each sounder base carrying a unique address, the FACP can then command an indvidual sounder — or a group ofsounders — to activate. The command set from the panel can be tailored to the specific event, allowing selection of volume, tone, and group. NOTE: The FCO-851(A) is compatible with the NFS-320(C), NFS- 320SYS, NFS2-640, and NFS2-3030 operating with firmware ver- sion 17.0 (or higher) in FlashScan® mode; CLIP mode not sup- ported. Features • Unique ability to detect all four major elements of a fire. • Separate CO detection signal. • Highest nuisance alarm immunity. • Automatic drift compensation of smoke sensor and CO cell. • Uses only one address on the SLC. • RealTest® CO testing capability. • Separates audible signal for fire or CO alarm when used with the B200S base (B200SCOA in Canada). • CO cell end-of-life warning and fault. • FlashScan operation. Sensitivity Settings and Suggested Applications •Level 1: 1% / ft of smoke. Suggested for very clean envi- ronments such as laboratories. •Level 2: 2% / ft of smoke. Suggested for clean environ- ments such as offices. •Level 3: 3% / ft of smoke. Suggested for moderately clean environments such as hotel rooms, dorm rooms. •Level 4: 3% / ft of smoke with different algorithm process- ing and weighting of sensor elements. Suggested for hotel rooms near a shower, boiler rooms. •Level 5: 4% / ft of smoke. Suggested for equipment rooms, kitchens, paint shops. •Level 6: Thermal alarm at 135°F (57°C). Once the CO cell has reached end-of-life, the CO sensor no longer provides life safety protection; however, when the fire detector enters Photo, Thermal, Infrared (PTIR) mode, the fol- lowing sensitivities apply: •Level 1: 1% / ft of smoke. Suggested for very clean envi- ronments such as laboratories. •Level 2: 2% / ft of smoke. Suggested for clean environ- ments such as offices. •Level 3: 3% / ft of smoke. Suggested for moderately clean environments such as hotel rooms, dorm rooms. •Level 6: Thermal alarm at 135°F (57°C). Specifications PHYSICAL SPECIFICATIONS Size: 3.46" (8.79 cm) high x 6.875" (17.46 cm) diameter installed in B200S(COA) base. Shipping weight: 4.6 oz. (130.41 g). Color: Ivory.60689cov.JPGFCO-851(A) in B200S(COA) Sounder Base Page 2 of 2 — DN-60689:B • 12/3/2012 IntelliQuad™ is a trademark and NOTIFIER®, RealTest® and FlashScan® are registered trademarks of Honeywell International Inc.©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Made in the U.S. A. Operating humidity range: 15% – 90% relative humidity (noncondensing). Operating temperature: 0°C to 38°C (32°F to 100°F). Air velocity: 0 – 4000 ft./min. (0 to 20 m/sec.). ELECTRICAL SPECIFICATIONS Operating Voltage range: 15 – 32 volts VDC. Standby current (max. avg.): 300 μA at 24 VDC (one com-munication every 5 seconds with LED blink enabled). Maximum Alarm Current (LED on): 7.2 mA at 24 VDC. CO ALARM ACTIVATION LEVELS Alarm activation levels as defined by UL Standard 2034: Ordering Information NOTE: “A suffix indicates ULC listed model. FCO-851: IntelliQuad PLUS Advanced Multi-Criteria Fire/CO Detector. FCO-851A: IntelliQuad PLUS Advanced Multi-Criteria Fire/CODetector, ULC listed. B200S: Intelligent programmable sounder base. B200SCOA: Intelligent programmable sounder base, ULClisted. Includes CO detector markings in English and French. M02-04-00: Detector Test Magnet. M02-09-00: Telescoping Test Magnet. Agency Listings and Approvals The listings and approvals below apply to the primary product. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. •UL: S1115 (FCO-851). •ULC: S1115 (FCO-851A). •CSFM: 7275-0028:0264. Concentration of CO Maximum Alarm Time Response 70 (+/- 5) PPM 240 min (not less than 60 min) 150 (+/- 5) PPM 50 min (not less than 10 min) 400 (+/- 10) PPM 15 min (not less than 4 min) DN-6937:D • 12/07/2011 — Page 1 of 2 FAPT-851(A) Acclimate® Plus™ Multi-Sensor Low-Profile Intelligent Detector Intelligent/Addressable Devices DN-6937:D General The Notifier FAPT-851(A) Acclimate® Plus™ detector is anintelligent, addressable, multi-sensing, low-profile detector designed for use with Notifier Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). The Acclimate Plus detector uses a combination of photoelec- tric and thermal sensing technologies to increase immunity to false alarms. Unlike traditional intelligent detectors, the Accli- mate Plus detector has a microprocessor in the detector head that processes alarm data. As a result, the Acclimate Plus detector adjusts its sensitivity automatically, without operator intervention or control panel programming. Areas where the Acclimate Plus detector is especially useful include office complexes, schools, college campuses, manu- facturing and industrial facilities, and anywhere else the use ofa particular area may change. The Acclimate Plus detector automatically adjusts its sensitivity to the environment. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed to greatly enhance the speed of communica- tion between analog intelligent devices and compatible systems. Intelligent devices communicate in a grouped fash- ion. If one of the devices within the group has new information,the panel’s CPU stops the group poll and concentrates on sin- gle points. The net effect is response speed greater than five times that of earlier designs. Features • Automatically adjusts sensitivity levels without operator intervention or programming. Sensitivity increases with heat. • Microprocessor-based, combination photo and thermal technology. • Compatible with all Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). • Addressable-analog communication. • Sleek, low-profile design. • Two-wire SLC connection. • Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). • Addresses can be viewed and changed without electronic programmers. • Dual bi-color LED design provides 360° viewing angle. • LEDs lock red when in alarm. In FlashScan, LEDs flash green in standby for normal condition. • Built-in tamper-resistant feature. • Constructed of off-white fire-resistant plastic, designed to commercial standards, and offers an attractive appearance. • SEMS screws for wiring of the separate base. • Several base options, including relay, isolator, and sounder. • Built-in functional test switch activated by external magnet. • Listed to UL 268. • Capable of heat-only alarm mode, enabled by a special command from the panel. Smoke alarms are ignored. • Low-temperature signal at 45°F +/– 10°F (7.22°C +/– 5.54°C). Specifications Sensitivity: auto-adjusting levels: 1 to 2%/ft. and 2 to 4%/ft. with classic CLIP systems; 1 to 2, 2 to 3, and 3 to 4%/ft. with systems; fixed-sensitivity levels: 1, 2, and 4%/ft. with classic CLIP systems; 0.5, 1, 2, 3, and 4%/ft. with FlashScan systems. Size: 2.0" (5.3 cm) high; base determines diameter. – B210LP(A): 6.1" (15.5 cm) diameter. – B501(A): 4.1" (10.4 cm) diameter. – B200S(A): 6.875" (17.46 cm) diameter. – B200SR(A): 6.875" (17.46 cm) diameter. – B224RB(A): 6.2" (15.748 cm) diameter. Shipping weight: 5.2 oz. (147 g). Operating temperature: 0°C to 38°C (32°F to 100°F). UL-Listed velocity range: 0 – 4000 ft./min. (1219.2 m/min.), suitable for installation in ducts. Relative humidity: 10% – 93% noncondensing. Thermal sensing rating: fixed-temperature setpoint 135°F (57°C). ELECTRICAL SPECIFICATIONS Voltage range: 15 – 32 volts DC peak. Standby current (max. avg.): 300 μA. Loop resistance: 50 ohms maximum; varies according to control panel used. Refer to panel installation manuals. LED current (max.): 6.5 mA @ 24 VDC (“ON”). Installation The FAPT-851(A) plug-in detector uses a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug-in and remove detec- tors without using a ladder. Suitable mounting base boxes include: FAPT-851(A) in B210LP(A) Base FAPT-851 with B210.png Page 2 of 2 — DN-6937:D • 12/07/2011 Notifier®, ONYX®, FlashScan®, and Acclimate® are registered trademarksand Acclimate Plus™ is a trademark of Honeywell International Inc.©2011 by Honeywell International Inc. All rights reserved. Unauthorized useof this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Made in the U.S. A. • 4.0" (10.16 cm) square box. • 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box. • Single-gang box (except relay or isolator base). NOTE: The FAPT-851(A) detector has the unique ability to adjust sensitivity according to the environment, based on heat and smoke levels. Avoid installing these detectors in locations that are susceptible to rapid and high temperature changes. An example of an incorrect application would be near or in line with the output of a self-contained heater. Agency Listings and Approvals These listings and approvals apply to the modules specified in this. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. •UL Listed: S1115. •ULC Listed: S1115. •MEA Listed: 225-02-E. • FM Approved. •CSFM: 7272-0028:0206. •U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/0 (NFS2-640/NFS-320/NFS-320C, excluding B210LP(A)). •Lloyd’s Register: 11/600013 (NFS2-640, NFS-320/NFS-320C, excluding B210LP(A)). •Maryland State Fire Marshal: Permit # 2122. Ordering Information NOTE: “A” suffix indicates ULC Listed model. FAPT-851: Low-profile intelligent multi-sensor detector. FAPT-851A: Same as FAPT-851 but with ULC Listing. INTELLIGENT BASES NOTE: “A” suffix indicates ULC Listed model. NOTE: For details about intelligent bases and their mounting, see DN-60054. B210LP(A): Plug-in detector base; standard U.S. flanged low- profile mounting base. B210LPBP: Bulk pack of B210LP; package contains 10. B501(A): Flangeless mounting base. B501BP: Bulk pack of B501; package contains 10. B200S(A): Intelligent, programmable sounder base capable of producing sound output in high or low volume with ANSI Tem- poral 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. B200SR(A): Intelligent sounder base capable of producingsound output with ANSI Temporal 3 or continuous tone. Replaces B501BH series bases in retrofit applications. B224RB(A): Relay base Screw terminals: up to 14 AWG (2.0mm²). Relay type Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. B224BI(A): Isolator base. Maximum: 25 devices between iso- lator bases. ACCESSORIES F110: Retrofit flange to convert B210LP to match the B710LP profile, or to convert older high-profile bases to low-profile. F110BP: Bulk pack of F110; package contains 15. F210: Replacement flange for B210LP(A) base. RA100Z(A): Remote LED annunciator. 3 – 32 VDC. Fits U.S. single-gang electrical box. Supported by B210LP(A) and B501(A) bases only. SMB600: Surface mounting kit for use with B210LP(A). M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of FlashScan® Series detector heads from base in high ceiling installations. T55-127-010: Detector removal tool without pole. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. DN-6936:B • 12/07/2011 — Page 1 of 2 FST-851(A) Series Intelligent Thermal (Heat) Detectors with FlashScan® Intelligent / Addressable Devices DN-6936:B • H-211 General Notifier FST-851(A) Series intelligent plug-in thermal detectorswith integral communication has features that surpass conven- tional detectors. Point ID capability allows each detector’s address to be set with rotary, decimal address switches, pro- viding exact detector locations. FST-851(A) Series thermal detectors use an innovative thermistor sensing circuit to pro- duce 135°F/57°C fixed-temperature (FST-851/A) and rate-of- rise thermal detection (FST-851R/A) in a low-profile package. FST-851H(A) provides fixed high-temperature detection at 190°F/88°C. These thermal detectors provide effective, intelli- gent property protection in a variety of applications. FST-851(A) Series detectors are compatible with Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). FlashScan® (U.S. Patent 5,539,389) is a communication pro-tocol developed by Notifier Engineering that greatly enhances the speed of communication between analog intelligent devices and certain NOTIFIER systems. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel’s CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. Features • Sleek, low-profile, stylish design. • State-of-the-art thermistor technology for fast response. • Rate-of-rise model (FST-851R/A), 15°F (8.3°C) per minute. • Factory preset fixed temperature at 135°F (57°C); high-tem- perature model fixed at 190°F (88°C). • Addressable by device. • Compatible with FlashScan® and CLIP protocol systems. • Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). • Two-wire SLC connection. • Visible LEDs “blink” every time the unit is addressed. • 360°-field viewing angle of the visual alarm indicators (two bi-color LEDs). LEDs blink green in Normal condition and turn on steady red in Alarm. • Integral communications and built-in device-type identifica- tion. • Remote test feature from the panel. • Built-in functional test switch activated by external magnet. • Walk test with address display (an address of 121 will blink the detector LED 12-(pause)-1). • Low standby current. • Backward-compatible. • Built-in tamper-resistant feature. • Designed for direct-surface or electrical-box mounting. • Sealed against back pressure. • Plugs into separate base for ease of installation and main- tenance. Separate base allows interchange of photoelec- tric, ionization and thermal sensors. • SEMS screws for wiring of the separate base. • Constructed of off-white fire-resistant plastic, designed to commercial standards, and offers an attractive appearance. • 94-5V plastic flammability rating. • Remote LED output connection to optional RA100Z(A) remote LED annunciator. • Optional sounder, relay, and isolator bases. • Optional flanced surface mounting kit. Specifications Size: 2.1" (5.3 cm) high; base determines diameter. – B210LP(A): 6.1" (15.5 cm) diameter. – B501(A): 4.1" (10.4 cm) diameter. – B200S(A): 6.875" (17.46 cm) diameter. – B200SR(A): 6.875" (17.46 cm) diameter. – B224RB(A): 6.2" (15.748 cm) diameter. – B224BI(A): 6.2" (15.748 cm) diameter. Shipping weight: 4.8 oz. (137 g). Operating temperature range: FST-851(A) Series, FST- 851R(A): –20°C to 38°C (–4°F to 100°F); FST-851H(A): –20°C to 66°C (–4°F to 150°F). Detector spacing: UL approved for 50 ft. (15.24 m) center to center. FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing. Relative humidity: 10% – 93% noncondensing. Thermal ratings: fixed-temperature setpoint 135°F (57°C), rate-of-rise detection 15°F (8.3°C) per minute, high tempera- ture heat 190°F (88°C). ELECTRICAL SPECIFICATIONS Voltage range: 15 - 32 volts DC peak. Standby current (max. avg.): 300 μA @ 24 VDC (one com- munication every 5 seconds with LED enabled). LED current (max.): 6.5 mA @ 24 VDC (“ON”). Applications Use thermal detectors for protection of property. For further information, go to systemsensor.com for manual I56-407-00, Applications Manual for System Smoke Detectors, which pro-vides detailed information on detector spacing, placement, zoning, wiring, and special applications. FST-851(A) in B210LP(A) Base B210-2251.jpg Page 2 of 2 — DN-6936:B • 12/07/2011 Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. ©2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Made in the U.S. A. Installation The FST Series plug-in intelligent thermal detectors use a sep- arate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. A spe- cial tool allows maintenance personnel to plug in and remove detectors without using a ladder Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junctionboxes, see DN-60054. NOTE: 1) Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring “T-taps” or branches are permitted for Style 4 (Class “B”) wiring. 2) When using relay or sounder bases, consult the ISO-X(A) installation sheet I56-1380 for device limitations between isolator modules and isolator bases. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document.In some cases, certain modules or applicationsmay not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. •UL Listed: S747. •ULC Listed: S6978. •MEA Listed: 383-02-E. • FM Approved. •CSFM: 7270-0028:0196. •BSMI: CI313066760025. •CCCF: Certif. # 2004081801000018. •U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/0 (NFS2-640/NFS-320/NFS-320C, excluding B210LP(A)). •Lloyd’s Register: 11/600013 (NFS2-640/NFS-320/NFS- 320C, excluding B210LP(A)). Product Line Information NOTE: “A” suffix indicates ULC Listed model. FST-851: Intelligent thermal detector. Must be mounted to one of the bases listed below. FST-851A: Same as FST-851 but with ULC Listing. FST-851R: Intelligent thermal detector with rate-of-rise fea-ture. FST-851RA: Same as FST-851R but with ULC Listing. FST-851H: Intelligent high-temperature thermal detector. FST-851HA: Same as FST-851H but with ULC Listing. INTELLIGENT BASES NOTE: “A” suffix indicates ULC Listed model. NOTE: For details about intelligent bases and their mounting, see DN-60054. B210LP(A): Standard U.S. flanged low-profile mounting base. B210LPBP: Bulk pack of B210LP; package contains 10. B501(A): Standard European flangeless mounting base. B501BP: Bulk pack of B501; package contains 10. B200S(A): Addressable Intelligent, programmable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501BH series bases in retrofit applications. B224RB(A): Intelligent relay base. Screw terminals: up to 14 AWG (2.0 mm²). Relay type: Form-C. Rating: 2.0 A @ 30 VDCresistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC induc- tive. B224BI(A): Intelligent isolator base. Isolates SLC from loopshorts. Maximum: 25 devices between isolator bases; see Note 2 under Installation. ACCESSORIES F110: Retrofit flange to convert B210LP(A) to match the B710LP(A) profile, or to convert older high-profile bases to low-profile. F110BP: Bulk pack of F110; package contains 15. F210: Replacement flange for B210LP(A) base. RA100Z(A): Remote LED annunciator. 3 – 32 VDC. Fits U.S. single-gang electrical box. Supported by B210LP(A) and B501(A) bases only. SMB600: Surface mounting kit, flanged. M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of FlashScan® Series detector heads from base in high ceiling installations. Includes T55-127-010. T55-127-010: Detector removal tool without pole. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. DN-6726:D • 4/13/2012 — Page 1 of 2 NBG-12LX Addressable Manual Pull Station Intelligent/Addressable Devices DN-6726:D • H-240 The NBG-12LX Addressable Manual Pull Station 6643cov1.jpg‘General The Notifier NBG-12LX is a state-of-the-art, dual-action (i.e.,requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel except FireWarden series panels, and the NSP- 25 panel. Because the NBG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word “ACTIVATED” appears to clearly indicate the station has been operated. • Captive screw terminals wire-ready for easy connection toSLC loop (accepts up to 12 AWG/3.25 mm² wire). • Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" (10.16 cm) square electrical box. • Smooth dual-action design. • Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. • Attractive shape and textured finish. • Key reset. • Includes Braille text on station handle. • Optional trim ring (BG12TR). • Meets UL 38, Standard for Manually Actuated Signaling Boxes. • Up to 99 NBG-12LX stations per loop on CLIP protocol loops. • Up to 159 NBG-12LX stations per loop on FlashScan® pro-tocol loops. • Dual-color LED blinks green to indicate normal onFlashScan® systems. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications •Shipping Weight: 9.6 oz. (272.15 g) •Normal operating voltage: 24 VDC. •Maximum SLC loop voltage: 28.0 VDC. •Maximum SLC standby current: 375 μA. •Maximum SLC alarm current: 5 mA. •Temperature Range: 32°F to 120°F (0°C to 49°C) •Relative Humidity: 10% to 93% (noncondensing) •For use indoors in a dry location Installation The NBG-12LX will mount semi-flush into a single-gang, dou- ble-gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O sur- face backbox. If the NBG-12LX is being semi-flush mounted,then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word “ACTI- VATED” (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 – 159 on FlashScan® systems, 1 – 99 on CLIP systems). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed ofred-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches(2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or Page 2 of 2 — DN-6726:D • 4/13/2012 NOTIFIER® and FlashScan® are registered trademarks of HoneywellInternational Inc.©2012 by Honeywell International Inc. All rights reserved. Unauthorized useof this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Made in the U.S. A. 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing thestate of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front ofthe station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. Product Line Information NBG-12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian appli- cations.) NBG-12LXSP: Spanish/English labelled version. NBG-12LXP: Portuguese labelled version. SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17021: Keys, set of two. NY-Plate: New York City trim plate. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. •UL/ULC Listed: S692 (listed for Canadian and non-Cana- dian applications). •MEA: 67-02-E. •CSFM: 7150-0028:0199. •FDNY: COA #6085 (NFS2-640), COA #6098 (NFS2-3030). •BSMI: CI313066760047. • U.S. Coast Guard. • Lloyd’s Register. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. DN-6724:B3 • 2/17/2011 — Page 1 of 2 FCM-1(A) & FRM-1(A) Series Control and Relay Modules Intelligent / Addressable Devices DN-6724:B3 General FCM-1(A) Control Module: The FCM-1(A) Addressable Con-trol Module provides Notifier intelligent fire alarm control pan- els a circuit for Notification Appliances (horns, strobes, speakers, etc.). Addressability allows the FCM-1(A) to be acti- vated, either manually or through panel programming, on a select (zone or area of coverage) basis. FRM-1(A) Relay Module: The FRM-1(A) Addressable Relay Module provides the system with a dry-contact output for acti- vating a variety of auxiliary devices, such as fans, dampers, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming,on a select basis. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER Engineering that greatlyenhances the speed of communication between analog intelli- gent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features • Built-in type identification automatically identifies thesedevices to the control panel. • Internal circuitry and relay powered directly by two-wire SLC loop. The FCM-1(A) module requires power (for horns, strobes, etc.), or audio (for speakers). • Integral LED “blinks” green each time a communication is received from the control panel and turns on in steady red when activated. • LED blink may be deselected globally (affects all devices). • High noise immunity (EMF/RFI). • The FCM-1(A) may be used to switch 24-volt NAC power, audio (up to 70.7 Vrms). • Wide viewing angle of LED. • SEMS screws with clamping plates for wiring ease. • Direct-dial entry of address 01– 159 for FlashScan loops, 01 – 99 for CLIP mode loops. • Speaker, and audible/visual applications may be wired for Class B or A (Style Y or Z). Applications The FCM-1(A) is used to switch 24 VDC audible/visual power, high-level audio (speakers). The FRM-1(A) may be pro- grammed to operate dry contacts for applications such as door holders or Air Handling Unit shutdown, and to reset four-wire smoke detector power. NOTE: Refer to the SLC Manual (PN 51253) for details regarding releasing applications with the FCM-1(A). Refer to the FCM-1-REL datasheet (DN-60390) for new FlashScan® releasing applications. Construction • The face plate is made of off-white heat-resistant plastic. • Controls include two rotary switches for direct-dial entry of address (01-159). • The FCM-1(A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. • The FRM-1(A) provides two Form-C dry contacts that switch together. Operation Each FCM-1(A) or FRM-1(A) uses one of 159 possible module addresses on a SLC loop (99 on CLIP loops). It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notifica- tion Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. The FCM-1(A) supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the FCM-1(A) will dis- connect the supervision and connect the external power sup- ply in the proper polarity across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the com- munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-inTYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a module and a sen- sor address. Specifications for FCM-1(A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 350 μA direct poll, 375 μA group poll with LED flashing, 485 μA Max. (LED flashing, NAC shorted.) FCM-1(A)7000cov.JPG Page 2 of 2 — DN-6724:B3 • 2/17/2011 Notifier® and FlashScan® are registered trademarks of HoneywellInternational Inc. ©2011 by Honeywell International Inc. All rights reserved. Unauthorized useof this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Made in the U.S. A. Maximum NAC Line Loss: 4 VDC. External supply voltage (between Terminals T10 and T11): Maximum (NAC): Regulated 24 VDC; Maximum (Speakers): 70.7 V RMS, 50W. Drain on external supply: 1.7 mA maximum using 24 VDC supply; 2.2 mA Maximum using 80 VRMS supply. Max NAC Current Ratings: For class B wiring system, thecurrent rating is 3A; For class A wiring system, the current rat- ing is 2A. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Specifications for FRM-1(A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 230 μA direct poll; 255 μA group poll. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Agency Listings and Approvals In some cases, certain modules may not be listed by certainapproval agencies, or listing may be in process. Consult fac- tory for latest listing status. •UL: S635 •ULC: S3705 (A version only) • FM Approved •CSFM: 7300-0028:0219 •MEA: 14-00-E •FDNY: COA #6067, #6065 Contact Ratings for FRM-1(A) NOTE: Maximum (Speakers): 70.7 V RMS, 50 W Product Line Information NOTE: “A” suffix indicates ULC Listed model. FCM-1(A): Intelligent Addressable Control Module. FRM-1(A): Intelligent Addressable Relay Module. A2143-20: Capacitor, required for Class A (Style Z) operation of speakers. SMB500: Optional Surface-Mount Backbox. CB500: Control Module Barrier — required by UL for separat- ing power-limited and non-power limited wiring in the samejunction box as FCM-1(A). NOTE: For installation instructions, see the following documents: •FCM-1(A) Installation document I56-1169. •FRM-1(A) Installation document I56-3502. •Notifier SLC Wiring Manual, document 51253. Current Rating Maximum Voltage Load Description Application 3 A 30 VDC Resistive Non-Coded 2 A 30 VDC Resistive Coded .9 A 110 VDC Resistive Non-Coded .9 A 125 VDC Resistive Non-Coded .5 A 30 VDC Inductive (L/R=5ms)Coded 1 A 30 VDC Inductive (L/R=2ms)Coded .3 A 125 VAC Inductive (PF=0.35)Non-Coded 1.5 A 25 VAC Inductive (PF=0.35) Non-Coded .7 A 70.7 VAC Inductive (PF=0.35) Non-Coded 2 A 25 VAC Inductive (PF=0.35) Non-Coded DN-6720:C • 10/06/2010 — Page 1 of 4 FMM-1(A), FMM-101(A), FZM-1(A) & FDM-1(A) Monitor Modules with FlashScan® Intelligent/Addressable Devices DN-6720:C • H-220 General Four different monitor modules are available for Notifier’s intel-ligent control panels for a variety of applications. Monitor mod- ules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (FZM-1(A)). FMM-1(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. FMM-101(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D that super- vises a Style B (Class B) circuit of dry-contact input devices.Its compact design allows the FMM-101(A) to be mounted in a single-gang box behind the device it monitors. FZM-1(A) is a standard-sized module that monitors and super-vises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. FDM-1(A) is a standard-sized dual monitor module that moni- tors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan® (U.S. Patent 5,539,389) is a communication pro-tocol developed by NOTIFIER that greatly increases the speed of communication between analog intelligent devices. Intelli- gent devices communicate in a grouped fashion. If one of thedevices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. FMM-1(A) Monitor Module • Built-in type identification automatically identifies this device as a monitor module to the control panel. • Powered directly by two-wire SLC loop. No additional power required. • High noise (EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. • Direct-dial entry of address: 01 – 159 on FlashScan loops; 01 – 99 on CLIP loops. • LED flashes green during normal operation (this is a pro- grammable option) and latches on steady red to indicate alarm. The FMM-1(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of eachmodule is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm andsupervisory devices. The module has a panel-controlled LED indicator. The FMM-1(A) can be used to replace MMX-1(A) modules in existing systems. FMM-1(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be usedto monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. FMM-1(A) OPERATION Each FMM-1(A) uses one of the available module addresseson an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FMM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 350 μA (LED flashing), 1 com-munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 40 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x2.125" (5.398 cm) deep box. FMM-1(A) (Type H)6999cov.jpg Page 2 of 4 — DN-6720:C • 10/06/2010 FMM-101(A) Mini Monitor Module • Built-in type identification automatically identifies this device as a monitor module to the panel. • Powered directly by two-wire SLC loop. No additional power required. • High noise (EMF/RFI) immunity. • Tinned, stripped leads for ease of wiring. • Direct-dial entry of address: 01 – 159 on FlashScan loops;01 – 99 on CLIP loops. The FMM-101(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat-ing device circuit for normally-open-contact fire alarm and security devices. The FMM-101(A) can be used to replace MMX-101(A) modules in existing systems. FMM-101(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit.A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. FMM-101(A) OPERATION Each FMM-101(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). FMM-101(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 μA, 1 communication every5 seconds, 47k EOL; 600 μA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 40 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 400 μA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. FZM-1(A) Interface Module • Supports compatible two-wire smoke detectors. • Supervises IDC wiring and connection of external powersource. • High noise (EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. • Direct-dial entry of address: 01 – 159 on FlashScan loops, 01 – 99 on CLIP loops. • LED flashes during normal operation; this is a programma- ble option. • LED latches steady to indicate alarm on command from control panel. The FZM-1(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The FZM-1(A)can be used to replace MMX-2(A) modules in existing sys- tems. FZM-1(A) APPLICATIONS Use the FZM-1(A) to monitor a zone of two-wire smoke detec- tors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of theStyle B or D (class B or A) circuit (maximum IDC loop resis- tance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. FZM-1(A) OPERATION Each FZM-1(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita-tions on the loop). FZM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Average operating current: 300 μA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrmsmaximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box.6720m101.wmf DN-6720:C • 10/06/2010 — Page 3 of 4 FDM1(A) Dual Monitor Module The FDM-1(A) Dual Monitor Module is intended for use in intelli- gent, two-wire systems. It provides two independent two-wireinitiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or nor- mally closed security devices. The module has a single panel- controlled LED. NOTE: The FDM-1(A) provides two Style B (Class B) IDC circuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. FDM-1(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 μA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 μA EOL resistance: 47K ohms. Maximum SLC Wiring resistance: 40 Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x2.125" (5.398 cm) deep. FDM-1(A) AUTOMATIC ADDRESSING The FDM-1(A) automatically assigns itself to two addressable points, starting with the original address. For example, if the FDM-1(A) is set to address “26”, then it will automatically assign itself to addresses “26” and “27”. NOTE: “Ones” addresses on the FDM-1(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. Installation FMM-1(A), FZM-1(A), and FDM-1(A) modules mount directlyto a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 sur- face-mount box. Mounting hardware and installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The FMM-101(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. •UL: S635 •ULC: S635 • FM Approved •CSFM: 7300-0028:0219 •MEA: 457-99-E •U.S. Coast Guard: –161.002/23/3 (AFP-200: FMM-1/-101, FZM-1) –161.002/42/1 (NFS-640: FMM-1/-101) •Lloyd’s Register: –03/60011/E1 (FMM-1/-101, FZM-1) –94/60004/E2 (AFP-200: except FDM-1) –02/60007 (NFS-640: FDM-1) •FDNY: COA #6038 (NFS2-640, NFS-320), COA# 6058(NFS2-3030) Product Line Information NOTE: “A” suffix indicates ULC-listed model. FMM-1(A): Monitor module. FMM-101(A): Monitor module, miniature. FZM-1(A): Monitor module, two-wire detectors. FDM-1(A): Monitor module, dual, two independent Class B cir- cuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51253. !CAUTION: Avoid duplicating addresses on the system. Page 4 of 4 — DN-6720:C • 10/06/2010 FlashScan® and NOTIFIER® are registered trademarks and FireWatch™ isa trademark of Honeywell International Inc.©2010 by Honeywell International Inc. All rights reserved. Unauthorized useof this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118.www.notifier.com Made in the U.S. A. DN-7087:C1 • 11/9/11 — Page 1 of 4 SpectrAlert® Advance Selectable Output Notification Appliances Audio/Visual Devices DN-7087:C1 General System Sensor® SpectrAlert® Advance selectable-outputhorns, strobes and horn/strobes are rich with features guaran- teed to cut installation times and maximize profits. The Spec- trAlert Advance series of notification appliances is designed to simplify your installations, with features such as: plug-in designs, instant feedback messages to ensure correct installa- tion of individual devices, and eleven field-selectable candela settings for wall and ceiling strobes and horn/strobes. More specifically, when installing Advance products, first attach a universal mounting plate to a four-inch square, four- inch octagon, or double-gang junction box. The two-wiremounting plate attaches to a single-gang junction box. Then, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. Finally, attach the horn, strobe, or horn/strobe to the mounting plate by inserting the product’s tabs in the mounting plate’s grooves. The device will rotate into position, locking the prod- uct’s pins into the mounting plate’s terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. SpectrAlert Advance products allow you to choose: • 12 or 24 volts. • 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, or 185 can- dela by way of a rear-mounted slide switch and front view- ing window. • Horn tones and volume by way of a rotary switch. • The SpectrAlert Advance series includes outdoor notifica- tion appliances. Outdoor strobes and horn/strobes (two- wire and four-wire) are available for wall or ceiling. Outdoorhorns are available for wall only. All System Sensor outdoor products are rated between –40°F and 151°F (–40°C and 66°C) in wet or dry applications. Models available: • Indoor wall-mount: horn, strobe, 2-wire horn/strobe, 4-wire horn/strobe. • Indoor ceiling-mount: strobe, 2-wire horn/strobe, 4-wirehorn/strobe. • Outdoor wall-mount: horn, strobe, 2-wire horn/strobe, 4- wire horn/strobe. • Outdoor ceiling-mount: strobe, 2-wire horn/strobe, 4-wire horn/strobe. Features • Plug-in design. • Same mounting plate for wall- and ceiling-mount units. • Shorting spring on mounting plate for continuity check before installation. • Captive mounting screw. • Tamper-resistance capability. • Field-selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185. • Automatic selection of 12 or 24 volt operation at 15 and 15/ 75 candela. • Outdoor wall and ceiling products. • Outdoor products rated from –40°F and 151°F (–40°C and 66°C). • Outdoor products rainproof per UL50 (NEMA 3R) and weatherproof per NEMA 4X, IP56 • Minimal intrusion into the backbox. • Horn rated at 88+ dbA at 16 volts. • Rotary switch for tone selection. • Three horn volume settings. • Electrically compatible with existing SpectrAlert products. Engineering Specifications SpectrAlert Advance horns, strobes, and horn/strobes shallmount to a standard 4.0" x 4.0" x 1.5" (10.16 x 10.16 x 3.81 cm) backbox, 4.0" (10.16 cm) octagonal backbox, or a double- gang backbox. Two-wire products shall also mount to a single- gang 2.0" x 4.0" x 1.875" (5.08 x 10.16 x 4.763 cm) backbox. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, Spec- trAlert Advance products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notifi- cation appliance circuit output and shall operate on a nominal12 or 24 volts. When used with the Sync•Circuit Module, 12- volt rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32°F and 120°F (0°C and 49°C) from a regulated DC, or full-wave-recti- fied, unfiltered power supply. Strobes and horn/strobes shallhave field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185. Indoor Ceiling Horn/Strobe Outdoor Ceiling Strobe Indoor Wall Horn/Strobe Indoor Ceiling Strobe Indoor WallHorn Outdoor WallStrobe7087pho1.jpg7087pho4.jpg7087pho3.jpg7087pho2.jpg7087pho5.jpg7087pho6.jpg Page 2 of 4 — DN-7087:C1 • 11/9/11 STROBE The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-sig- naling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appli- ances, flashing at 1 Hz over the strobe’s entire operating volt- age range. The strobe light shall consist of a xenon flash tubeand associated lens/reflector system. HORN/STROBE COMBINATION The horn/strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act require- ments for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector sys-tem. The horn shall have three audibility options and an option to switch between a Temporal 3 pattern and a Non-Temporal (continuous) pattern. These options are set by a multiple posi- tion switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn/strobe models shall operate on a coded or non-coded power supply. OUTDOOR PRODUCTS SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between –40°F and 151°F (–40°C and 66°C). The productsshall be listed for use with a System Sensor outdoor/weather- proof backbox with half-inch and three-fourths-inch conduit entries. SYNCHRONIZATION MODULE The module shall be a System Sensor Sync•Circuit MDL3R or MDL3W listed to UL 464 and shall be approved for fire protec- tive service. The module shall synchronize SpectrAlert strobesat 1 Hz and horns at Temporal 3. Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a single pair of wires. The module shall mount to a 4.688" x 4.688" x 2.125" (11.906 x 11.906 x 5.398 cm) back- box. The module shall also control two Style Y (class B) cir- cuits or one Style Z (Class A) circuit. The module shall synchronize multiple zones. Daisy-chaining two or more syn- chronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Operating Specifications •Standard operating temperature: 32°F to 120°F (0°C to 49°C). •K Series operating temperature: –40°F to 151°F (–40°C to 66°C). •Humidity range: 10% to 93% non-condensing (indoor products). •Strobe flash rate: 1 flash per second. •Nominal voltage: regulated 12 VDC/FWR or regulated 24 VDC/FWR. NOTE: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. •Operating voltage range: 8 V to 17.5 V (12 V nominal); or16 V to 33 V (24 V nominal). NOTE: P, S, PC, and SC prod- ucts will operate at 12 V nominal only for 15 cd and 15/75 cd. •Input terminal wire gauge: 12 to 18 AWG (3.31 to 0.821 mm²). •Ceiling-mount dimensions (including lens): 6.8" diame- ter x 2.5" deep (17.3 cm diameter x 6.4 cm deep). •Wall-mount dimensions (including lens): 5.6" H x 4.7" Wx 2.5" D (14.2 cm H x 11.9 cm W x 6.4 cm D). •Horn dimensions: 5.6" H x 4.7" W x 1.3" D (14.2 cm H x11.9 cm W x 3.3 cm D). Agency Listings and Approvals The listings and approvals below apply to SpectrAlert Advance Selectable Output Notification Devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing sta- tus. •UL Listed: S4011 (HR__, HW__, P2__, P4__, PC2__, PC4__ models); S5512 (models SCR, SCRH, SCW, SCWH, SR, SRH, SW, SWH); S3593 (SCRHK, SCRK, SRHK, SRK). •ULC Listed: S4011 (HRA, HRKA); S5512 (typically “A” models, with exception of outdoor strobes). See Canadian data sheet for listings and specifications. •FM approved •MEA: 452-05-E •CSFM: 7125-1653:0186 (SCR, SCRH, SCW, SCWH, SR, SRH, SW, SWH); 7300-1653:0188 (P2_, P4_, PC2_, PC4_ modules); 7135-1653:0189 (HR, HRK, HW); 7300- 1653:0187 (SCRHK, SCRK, SRHK, SRK). Strobe Current Draw, UL Maximum (mA RMS) Candela 8 – 17.5 V 16 – 33 V DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA N/A 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High Candela Range 135 NA NA 228 207 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 Horn Current Draw, UL Maximum (mA RMS) Sound Pattern dB 8 – 17.5 V 16 – 33 V DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-temporal High 57 56 69 75 Non-temporal Medium 42 50 60 69 Non-temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 DN-7087:C1 • 11/9/11 — Page 3 of 4 Two-Wire Horn/Strobe, STANDARD Candela Range (15 – 115 cd), UL Maximum Current Draw (mA RMS) Input, Sound Pattern, dB Level 8 – 17.5 V 16 – 33 V 15 15/75 15 15/75 30 75 95 110 115 DC Input, Temporal, High 137 147 79 90 107 176 194 212 218 DC Input, Temporal, Medium 132 144 69 80 97 157 182 201 210 DC Input, Temporal, Low 132 143 66 77 93 154 179 198 207 DC Input, Non-temporal, High 141 152 91 100 116 176 201 221 229 DC Input, Non-temporal, Medium 133 145 75 85 102 163 187 207 216 DC Input, Non-temporal, Low 131 144 68 79 96 156 182 201 210 FWR Input, Temporal, High 136 155 88 97 112 168 190 210 218 FWR Input, Temporal, Medium 129 152 78 88 103 160 184 202 206 FWR Input, Temporal, Low 129 151 76 86 101 160 184 194 201 FWR Input, Non-temporal, High 142 161 103 112 126 181 203 221 229 FWR Input, Non-temporal, Medium 134 155 85 95 110 166 189 208 216 FWR Input, Non-temporal, Low 132 154 80 90 105 161 184 202 211 Two-Wire Horn/Strobe, HIGH Candela Range (135 – 185 cd), UL Maximum Current Draw (mA RMS) DC Input 16 – 33 V FWR Input 16 – 33 V 135 150 177 185 135 150 177 185 DC, Temporal, High 245 259 290 297 FWR, Temporal, High 215 231 258 265 DC, Temporal, Medium 235 253 288 297 FWR, Temporal, Medium 209 224 250 258 DC, Temporal, Low 232 251 282 292 FWR, Temporal, Low 207 221 248 256 DC, Non-temporal, High 255 270 303 309 FWR, Non-temporal, High 233 248 275 281 DC, Non-temporal, Medium 242 259 293 299 FWR, Non-temporal, Medium 219 232 262 267 DC, Non-temporal, Low 238 254 291 295 FWR, Non-temporal, Low 214 229 256 262 7087dim12009.tif 2.5 2.5” 4.7” 5.6” 6.8” Horn and Horn/Strobe Output (dBA) SwitchPosition Sound Pattern dB 8 – 17.5 V 16 – 33 V DC FWR DC FWR 1 Temporal High 78 78 84 84 2 Temporal Medium 74 74 80 80 3 Temporal Low 71 73 76 76 4 Non-temporal High 82 82 88 88 5 Non-temporal Medium 78 78 85 85 6 Non-temporal Low 75 75 81 81 7* Coded High 82 82 88 88 8* Coded Medium 78 78 85 85 9* Coded Low 75 75 81 81 *NOTE: Settings 7, 8, and 9 are not available on 2-wire horn/strobe. Horn and Horn/Strobe Rotary Switch Setting Setting Repetition Rate dB Level 1 Temporal horn High 2 Temporal horn Medium 3 Temporal horn Low 4 Normal horn High 5 Normal horn Medium 6 Normal horn Low 7* Externally coded High 8* Externally coded Medium 9* Externally coded Low *NOTE: Settings 7, 8, and 9 are not available on 2-wire horn/strobe. Page 4 of 4 — DN-7087:C1 • 11/9/11 Sync•Circuit™ is a trademark and NOTIFIER® and SpectrAlert® areregistered trademarks of Honeywell International Inc. ©2011 by Honeywell International Inc. All rights reserved. Unauthorized useof this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Ordering Information Model Description Model Description WALL HORN/STROBES CEILING HORN/STROBES P2R 2-wire horn/strobe, standard cd, red.PC2R 2-wire horn/strobe, standard cd, red. P2RH 2-wire horn/strobe, high cd, red.PC2RH 2-wire horn/strobe, high cd, red. P2RK 2-wire horn/strobe, standard cd, red, outdoor.PC2RK 2-wire horn/strobe, standard cd, red, outdoor. P2RHK 2-wire horn/strobe, high cd, red, outdoor.PC2RHK 2-wire horn/strobe, high cd, red, outdoor. P2W 2-wire horn/strobe, standard cd, white.PC2W 2-wire horn/strobe, standard cd, white. P2WH 2-wire horn/strobe, high cd, white.PC2WH 2-wire horn/strobe, high cd, white. P4R 4-wire horn/strobe, standard cd, red.PC4R 4-wire horn/strobe, standard cd, red. P4RH 4-wire horn/strobe, high cd, red.PC4RH 4-wire horn/strobe, high cd, red. P4RK 4-wire horn/strobe, standard cd, red, outdoor.PC4RK 4-wire horn/strobe, standard cd, red, outdoor. P4RHK 4-wire horn/strobe, high cd, red, outdoor.PC4RHK 4-wire horn/strobe, high cd, red, outdoor. P4W 4-wire horn/strobe, standard cd, white.PC4W 4-wire horn/strobe, standard cd, white. P4WH 4-wire horn/strobe, high cd, white.PC4WH 4-wire horn/strobe, high cd, white. WALL STROBES CEILING STROBES SR Strobe, standard cd, red.SCR Strobe, standard cd, red. SRH Strobe, high cd, red.SCRH Strobe, high cd, red. SRK Strobe, standard cd, red, outdoor.SCRK Strobe, standard cd, red, outdoor. SRHK Strobe, high cd, red, outdoor.SCRHK Strobe, high cd, red, outdoor. SW Strobe, standard cd, white.SCW Strobe, standard cd, white. SWH Strobe, high cd, white.SCWH Strobe, high cd, white. ACCESSORIES HORNS BBS-2A Backbox skirt, wall, red.HR Horn, red. BBSW-2A Backbox skirt, wall, white.HRK Horn, red, outdoor. BBSC-2A Backbox skirt, ceiling, red.HW Horn, white. BBSCW-2A Backbox skirt, ceiling, white. ACCESSORIES, continued SA-WBB Weatherproof backbox, wall.TR-HS Trim Ring, wall, red, package of 5 SA-WBBC Weatherproof backbox, ceiling. TRW-HS Trim Ring, wall, white, package of 5 WTP Weatherproof, flush mount plate, red TRC-HS Trim Ring, ceiling, red, package of 5 WTPW Weatherproof, flush mount plate, white TRCW-HS Trim Ring, ceiling, white, package of 5 NOTE: “High cd” refers to strobes that include 135, 150, 177, and 185 candela settings. “Standard cd” refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. NOTE: For strobes and horn/strobes, add suffix “F” for French or “B” for Bilingual. NOTE: All outdoor models (“K(A)” suffix) include a plastic weatherproof backbox. NOTE: Add “-R” to models for weatherproof replacement device (no back box included). Only for use with weatherproof outdoor flush mounting plate, WTP and WTPW. NOTE: Add “P” to model for plain housing. (No “FIRE” marking on cover.)