VVMC Elev Upgrade #2 Permit Letter 07-10-2014-Signed.pdf
4100U TRANSPONDER LOCATED IN FIRE COMMAND CENTER Standby Total Alarm Total Module Qty Description Current Standby Current Alarm Panel Equipment 4100-9601 1 LOCAL MODE TRANSPONDER 0.087000 0.087000 0.087 0.087000 4100-0634 2 POWER DISTRIBUTION MODULE 120V 0.000000 0.000000 0 0.000000 4100-3206 1 8 RELAYS - 3 AMP 0.015000 0.015000 0.19 0.190000 4100-5005 9 ZONE MODULE, 8 IDC, CLASS B 0.075000 0.675000 0.195 1.755000 4100-5101 2 EXPANSION PWR SUPPLY (XPS) - 120VAC 60HZ 0.050000 0.100000 0.05 0.100000 4100-5115 2 EXPANSION NAC MODULE - 3 NACS 0.025000 0.050000 0.025 0.050000 4100-5128 2 EXTERNAL BATTERY POWER 0.000000 0.000000 0 0.000000 4100-5111 1 SYSTEM PWR SUPPLY (SPS) - 120VAC 60HZ 0.175000 0.175000 0.225 0.225000 Total Panel Stby 1.102000 Total Panel Alarm 2.407000 Peripheral Devices 4603-9101 1 SERIAL LCD ANNUNCIATOR 0.030000 0.030000 0.17 0.170000 4098-9714 100 TRUEALARM PHOTO SMOKE SENSOR 0.000000 0.000000 0 0.000000 4098-9733 8 TRUEALARM HEAT SENSOR 0.000000 0.000000 0 0.000000 4099-9003 7 IDNET DOUBLE ACTION PULL STATION *0.000000 0.000000 0 0.000000 4090-9001 11 IDNET SUPERVISED IAM *0.000000 0.000000 0 0.000000 4090-9002 2 IDNET RELAY IAM *0.000000 0.000000 0 0.000000 4009-9201 2 4009 IDNET NAC EXTENDER, 120 VAC 0.000000 0.000000 0.000000 0.000000 2088-9608 10 MAGNETIC DOOR HOLDER, SEMI-FLUSH 0.015000 0.150000 0 0.000000 4099-9003 3 IDNET DOUBLE ACTION PULL STATION *0.000000 0.000000 0 0.000000 4098-9714 90 TRUEALARM PHOTO SMOKE SENSOR 0.000000 0.000000 0 0.000000 4098-9733 4 TRUEALARM HEAT SENSOR 0.000000 0.000000 0 0.000000 4098-9792 202 TRUEALARM SENSOR BASE *0.000000 0.000000 0 0.000000 4090-9002 2 IDNET RELAY IAM *0.000000 0.000000 0 0.000000 4098-9756 9 TRUEALARM DUCT SMOKE SENSOR W/ RELAY OUTPUT *0.002400 0.021600 0.015 0.135000 2098-9806 9 REMOTE TEST STATION W/ LED AND KEY SWITCH 0.000000 0.000000 0 0.000000 4098-9843 9 ENCAPSULATED RELAY PAM-SD 0.000000 0.000000 0.015 0.135000 Miscellaneous Outside Purchased Items Requiring System Power 302-AW-135 2 Thermal Detector, Weatherproof 0.000000 0.000000 1.000000 2.000000 302-AW-135 1 Thermal Detector, Weatherproof 0.000000 0.000000 1.000000 1.000000 Total Periph Stby 0.2016 Total Periph Alarm 3.440 Total Standby Amps 1.304 Total Alarm Amps 5.847 * Additional Current Draw Included With Device Addresses Used (See additional current draws) 1. 2-wire detector alarm current is included in the alarm current of the Initiating Device Circuit. Standby AlarmBattery Set #1 (Cabinet/Charger #1) Qty Current Current Cabinet #1 Card Power 1.102 Backup Amplifier 2.407 Current Draw For 100 Watt Or 95 Watt Amplifiers 0 0.000 0 0.000 Current Draw For Flex 35 and 50 Watt Amplifiers 0 0.000 0.000 Power For External Peripheral Devices 0.20160 3.44000 1.304 <-- Sub Totals --> 5.847 Additional Current Draws RUI Connected Peripheral Devices 1 0.004 0.004 MAPNET/IDNet Device Addresses ordered / used 238 238.0 0.190 0.236 Spare addressable point capacity included for battery calc 5%12 0.010 0.012 1.507 <--Grand Totals -->6.098 Additional Battery Capacity Required 20%0.301 1.220 Standby Time =4 Hrs 7.233 Standby Ah Alarm Time =15 Mins. 1.829 Alarm Ah Standby + Alarm = 9.062 Battery Required 2081-9275 18AH 13.567 Total Ah Required (see note below)Battery Supplied 2081-9275 18AH Note: The total Ah required takes into account any physical and chemical properties of battery discharge rates, high alarm current draw of a battery after a long (standby) low current draw, and reflects the manufacturers discharge rates per their recommendations and UL standards. VAIL VALLEY MEDICAL CENTER 4100U Transponder Panel Idnet Channel #6 Idnet Number Device Type Room Number (Max 40 Characters) M6-85 SMOKE M6-85 2ND FLR ICU ROOM200C M6-86 SMOKE M6-86 2ND FLR ICU ROOM 200B M6-87 SMOKE M6-87 2ND FLR ICU ROOM 200A M6-88 SMOKE M6-88 2ND FLR ICU CORR BY RM 200A M6-89 SMOKE M6-89 2ND FLR ICU ANTE RM M6-90 SPARE M6-91 SMOKE M6-91 2ND FLR ICU EAST ENTRANCE M6-92 SMOKE M6-92 2ND FLR PCU ENTRANCE CORRIDOR M6-93 PULL M6-93 2ND FLR PCU ENTRANCE CORRIDOR M6-94 IAM M6-94 NORTH PCU WATERFLOW M6-95 IAM M6-95 NORTH PCU TAMPER M6-96 IAM M6-96 WEST PCU WATRTFLOW M6-97 IAM M6-97 WEST PCU TAMPER M6-98 DUCT M6-98 2ND FLR SHC CLINIC AHU2 M6-99 SPARE M6-100 SMOKE M6-100 2ND FLR ELEV 1 TOP OF SHAFT M6-101 IAM M6-101 2ND FLR PCU NORTH PAT SHWR HEAT M6-102 HEAT M6-102 2ND FLR PCU NORTH BATH M6-103 IAM M6-103 2ND FLR PCU WEST PAT SHWR HEAT M6-104 HEAT M6-104 2ND FLR ICU PATIENT SHOWER M6-105 HEAT M6-105 2ND FLR ICU STAFF RESTROOM M6-106 HEAT M6-106 2ND FLR ICU PUBLIC RESTROOM M6-107 SMOKE M6-107 2ND FLR REAR HALL BATH 240 M6-108 SMOKE M6-108 2ND FLR REAR HALL JANITOR 241 M6-109 SMOKE M6-109 2ND FLR WORKROOM 243 M6-110 SMOKE M6-110 2ND FLR SLEEP ROOM 242 Features TrueAlarm analog sensing provides: Digital transmission of analog sensor values via IDNet or MAPNET II two-wire communications For use with the following Simplex® products: 4100ES, 4100U, 4010ES, and 4010 Series control panels; and 4008 Series control panels with reduced feature set (refer to data sheet S4008-0001 for details) 4020, 4100, and 4120 Series control panels, Universal Transponders, and 2120 TrueAlarm CDTs equipped for MAPNET II operation Fire alarm control panel provides: Peak value logging allowing accurate analysis of each sensor for individual sensitivity selection Sensitivity monitoring satisfying NFPA 72 sensitivity testing requirements; automatic individual sensor calibration check verifies sensor integrity Automatic environmental compensation, multi-stage alarm operation, and display of sensitivity directly in percent per foot Ability to display and print detailed sensor information in plain English language Photoelectric smoke sensors provide: Seven levels of sensitivity from 0.2% to 3.7% (refer to additional information on page 3) Heat sensors provide: Fixed temperature sensing Rate-of-rise temperature sensing Utility temperature sensing Listed to UL 521 and ULC-S530 General features: Listed to UL 268 and ULC-S529 Louvered smoke sensor design enhances smoke capture by directing flow to chamber; entrance areas are minimally visible when ceiling mounted Designed for EMI compatibility Magnetic test feature is provided Different bases are available to support a supervised or unsupervised output relay, and/or a remote LED alarm indicator Additional base reference: For isolator bases, refer to data sheet S4098-0025 For sounder bases, refer to data sheet S4098-0028 For photo/heat sensors, refer to data sheet S4098-0024 (single address) and S4098-0033 (dual address) * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listings 7272-0026:218, 7271-0026:231, 7270-0026:216, and 7300-0026:217 for allowable values and/or conditions concerning material presented in this document. Accepted for use – City of New York Department of Buildings – MEA35-93E. Additional listings may be applicable, contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. 4098-9714 TrueAlarm Photoelectric Sensor Mounted in Base Description Digital Communication of Analog Sensing. TrueAlarm analog sensors provide an analog measurement digitally communicated to the host control panel using Simplex addressable communications. At the control panel, the data is analyzed and an average value is determined and stored. An alarm or other abnormal condition is determined by comparing the sensor’s present value against its average value and time. Intelligent Data Evaluation. Monitoring each sensor’s average value provides a continuously shifting reference point. This software filtering process compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. With this filtering, there is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each TrueAlarm sensor is determined at the host control panel, selectable as more or less sensitive as the individual application requires. Timed/Multi-Stage Selection. Sensor alarm set points can be programmed for timed automatic sensitivity selection (such as more sensitive at night, less sensitive during day). Control panel programming can also provide multi-stage operation per sensor. For example, a 0.2% level may cause a warning to prompt investigation while a 2.5% level may initiate an alarm. Sensor Alarm and Trouble LED Indication. Each sensor base’s LED pulses to indicate communications with the panel. If the control panel determines a sensor is in alarm, or is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor base’s LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify the alarmed sensors. TrueAlarm Analog Sensing UL, ULC, CSFM Listed; FM Approved; TrueAlarm Analog Sensors – Photoelectric MEA (NYC) Acceptance* and Heat; Standard Bases and Accessories S4098-0019-18 6/2014 ALARM Sensor Base Features Base mounted address selection: Address remains with its programmed location Accessible from front (DIP switch under sensor) General features: Automatic identification provides default sensitivity when substituting sensor types Integral red LED for power-on (pulsing), or alarm or trouble (steady on) Locking anti-tamper design mounts on standard outlet box Magnetically operated functional test Sensor Bases 4098-9792, Standard Sensor Base 4098-9789, Sensor Base with wired connections for: 2098-9808 Remote LED alarm indicator or 4098-9822 relay (relay is unsupervised and requires separate 24 VDC) Supervised Relay Bases (not compatible with 2120 CDT): 4098-9791, 4-Wire Sensor Base, use with remote or locally mounted 2098-9737 relay, requires separate 24 VDC 4098-9780, 2-Wire Sensor Base, use with remote or locally mounted 4098-9860 relay, no separate power required Supervised relay operation is programmable and can be manually operated from control panel Includes wired connections for remote LED alarm indicator or 4098-9822 relay (relay is unsupervised and requires separate 24 VDC) Sensor Base Options 2098-9737, Remote or local mount supervised relay: DPDT contacts for resistive/suppressed loads, power limited rating of 3 A @ 28 VDC; non-power limited rating of 3 A @ 120 VAC (requires external 24 VDC coil power) 4098-9860, Remote or local mount supervised relay: SPDT dry contacts, power limited rating of 2 A @ 30 VDC, resistive; non-power limited rating of 0.5 A @ 125 VAC, resistive 4098-9822, LED Annunciation Relay: Activates when base LED is on steady, indicating local alarm or trouble DPDT contacts for resistive/suppressed loads, power limited rating of 2 A @ 28 VDC; non-power limited rating of 1/2 A @ 120 VAC, (requires external 24 VDC coil power) 4098-9832, Adapter plate: Required for surface or semi-flush mounting to 4” square electrical box and for surface mounting to 4” octagonal box Can be used for cosmetic retrofitting to existing 6-3/8” diameter base product 2098-9808, Remote red LED Alarm Indicator: Mounts on single gang box (shown in illustration to right) Description TrueAlarm sensor bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric or heat sensors. Each sensor’s output is digitized and transmitted to the system fire alarm control panel every four seconds. Since TrueAlarm sensors use the same base, different sensor types can be easily interchanged to meet specific location requirements. This feature also allows intentional sensor substitution during building construction. When conditions are temporarily dusty, instead of covering the smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. Although the control panel will indicate an incorrect sensor type, the heat sensor will operate at a default sensitivity providing heat detection for building protection at that location. Mounting Reference Electrical Box Requirements: (boxes are by others) Without relay in the box:4" octagonal or 4" square, 1-1/2" deep; single gang, 2" deep With relay in the box :4" octagonal or 4" square, 1-1/2" deep, with 1-1/2" extension ring TrueAlarm Bases 4098-9780, 4098-9789, 4098-9791, & 4098-9792 4-7/8" (124 mm) 15/16" (24 mm) 6-3/8" (162 mm) 1/4" (6.4 mm) 4098-9832 Adapter Plate, required for mounting to surface mounted boxes and 4"squareflush box 2098-9737 Supervised Relay (mounts in base electrical box or remotely) 4098-9822 Relay (mounts in base electrical box) NOTE:Review total wire count, wire size, and accessories being wired to determine required box volume. Relay Size: 2-1/2" X 1-1/2" X 1" (3.75 in3 ) (64 mm X 38 mm X 25.4 mm) 4098-9860 Supervised Relay (mounts in base electrical box or remotely; 2-3/8" X 1-1/4" X 11/32" (1 in3 ) (60.4 mm X 31.8 mm X 8.6 mm) Surface mount reference 4" (102 mm) Square Box 4" (102 mm) Octagonal Box Flush mount reference, mount even with final surface, or with up to 1/4" (6.4 mm) maximum recess 1-1/2" (38 mm) minimum box depth 2 S4098-0019-18 6/2014 TrueAlarm Sensor Bases and Accessories TrueAlarm Sensors Features Sealed against rear air flow entry Interchangeable mounting EMI/RFI shielded electronics Heat sensors: Selectable rate compensated, fixed temperature sensing with or without rate-of-rise operation Rated spacing distance between sensors: Fixed Temp. Setting UL & ULC Spacing FM Spacing, Either Fixed Temperature Setting 135° F (57.2° C) 60 ft x 60 ft (18.3 m) 20 ft x 20 ft (6.1 m) for fixed temperature only; RTI = Quick 50 ft x 50 ft (15.2 m) for fixed temperature with either rate-of-rise selection; RTI = Ultra Fast 155° F (68° C) 40 ft x 40 ft (12.2 m) Smoke Sensors: Photoelectric technology sensing 360° smoke entry for optimum response Built-in insect screens 4098-9714 Photoelectric Sensor TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. Seven levels of sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivities of 0.2%, 0.5%, and 1% are for special applications in clean areas. Standard sensitivities are 1.5%, 2.0%, 2.5%, 3.0%, and 3.7%. Application type and sensitivity are selected and then monitored at the fire alarm control panel.* The sensor head design provides 360° smoke entry for optimum response to smoke from any direction. Due to its photoelectric operation, air velocity is not normally a factor, except for impact on area smoke flow. 2-1/8" (54 mm) LED status indicator 4-7/8" (124 mm) 4098-9714 Photoelectric Sensor with Base 4098-9733 Heat Sensor TrueAlarm heat sensors are self-restoring and provide rate compensated, fixed temperature sensing, selectable with or without rate-of-rise temperature sensing. Due to its small thermal mass, the sensor accurately and quickly measures the local temperature for analysis at the fire alarm control panel. Rate-of-rise temperature detection is selectable at the control panel for either 15° F (8.3° C) or 20° F (11.1° C) per minute. Fixed temperature sensing is independent of rate-of-rise sensing and programmable to operate at 135° F (57.2° C) or 155° F (68° C). In a slow developing fire, the temperature may not increase rapidly enough to operate the rate-of-rise feature. However, an alarm will be initiated when the temperature reaches its rated fixed temperature setting. TrueAlarm heat sensors can be programmed as a utility device to monitor for temperature extremes in the range from 32° F to 155° F (0° C to 68° C). This feature can provide freeze warnings or alert to HVAC system problems. Refer to specific panels for availability. 2-3/8" (60 mm) LED status indicator 4-7/8" (124 mm) 4098-9733 Heat Sensor with Base WARNING: In most fires, hazardous levels of smoke and toxic gas can build up before a heat detection device would initiate an alarm. In cases where Life Safety is a factor, the use of smoke detection is highly recommended. Application Reference Sensor locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm and Signaling Code. On smooth ceilings, smoke sensor spacing of 30 ft (9.1 m) may be used as a guide.* * For detailed application information including sensitivity selection, refer to Installation Instructions 574-709. 3 S4098-0019-18 6/2014 TrueAlarm Sensor Bases (for use with Sensors 4098-9714 and 4098-9733) (Refer to Application Manual 574-709 and Installation Instructions 574-707 for additional information) Model Description Compatibility Mounting Requirements 4098-9792 Standard Sensor Base No options 4” octagonal or 4” square box, 1-1/2” min. depth; or single gang box, 2” min. depth 4098-9789 Sensor Base with connections for Remote LED Alarm Indicator or Unsupervised Relay 2098-9808 Remote Alarm Indicator or 4098-9822 Unsupervised Relay 4” octagonal or 4” square box Note: Box depth requirements depend on total wire count and wire size, refer to accessories list below for reference. ** NOTE: 4098-9791 and 4098-9780 are NOT compatible with the 2120 CDT 4098-9791** 4-Wire Sensor Supervised Relay Base with connections for LED Indicator or Unsupervised Relay 2098-9737 Supervised Remote Relay 2098-9808 Remote Alarm Indicator or 4098-9822 Unsupervised Relay 4098-9780** 2-Wire Sensor Supervised Relay Base with connections for LED Indicator or Unsupervised Relay 4098-9860 Supervised Remote Relay 2098-9808 Remote Alarm Indicator or 4098-9822 Unsupervised Relay TrueAlarm Sensors Model Description Compatibility Mounting Requirements 4098-9714 Photoelectric Smoke Sensor Bases 4098-9792, 4098-9789, 4098-9791, and 4098-9780 Refer to base requirements 4098-9733 Heat Sensor TrueAlarm Sensor/Base Accessories Model Description Compatibility Mounting Requirements 2098-9737 Supervised Relay, mounts remote or in base electrical box For use with 4098-9791 base Remote Mounting requires 4” octagonal or 4” square box, 1-1/2” minimum depth Base Mounting requires 4” octagonal box, 2-1/8” deep with 1-1/2” extension ring4098-9860 Supervised Relay, mounts remote or in base electrical box For use with 4098-9780 base 2098-9808 Remote Red LED Alarm Indicator on single gang stainless steel plate Bases 4098-9789, 4098-9791, and 4098-9780 Single gang box, 1-1/2” minimum depth 4098-9822 Unsupervised Relay, tracks base LED status; Note: Mounts only in base electrical box Bases 4098-9789, 4098-9791, and 4098-9780 4” octagonal box, 2-1/8” deep with 1-1/2” extension ring 4098-9832 Adapter Plate Bases 4098-9792, 4098-9789, 4098-9791, and 4098-9780 Required for surface or semi-flush mounted 4” square box and for surface mounted 4” octagonal box TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are trademarks of the National Fire Protection Association (NFPA). Tyco Fire Protection Products • Westminster, MA • 01441-0001 • USA S4098-0019-18 6/2014 www.simplex-fire.com © 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. General Operating Specifications Communications and Sensor Supervisory Power IDNet or MAPNET II communications, auto-selected, 1 address per base Communications Connections Screw terminals for in/out wiring, 18 to 14 AWG (0.82 mm2 to 2.08 mm2) Remote LED Alarm Indicator Current 1 mA typical, no impact to alarm current Remote LED Alarm Indicator and Relay Connections Color coded wire leads, 18 AWG (0.82 mm2 ) UL Listed Operating Temperature Range 32° to 100° F (0° to 38° C) Operating Temperature Range with 4098-9733 Heat Sensor 32° to 122° F (0° to 50° C) with 4098-9714 Smoke Sensor 15° to 122° F (-9° to 50° C) Storage Temperature Range 0° F to 140° F (-18° C to 60° C) Humidity Range 10 to 95% RH 4098-9714 Smoke Sensor Air Velocity Rating 0-4000 ft/min (0-1220 m/min) Housing Color Frost White 4098-9791 Base With Supervised Remote Relay 2098-9737 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current 270 A, from 24 VDC supply Alarm Current with 2098-9737 Relay 28 mA, from 24 VDC supply 4098-9780 Base With Supervised Remote Relay 4098-9860 (see page 2 for contact ratings) Power Supplied from communications 4098-9822 Unsupervised Relay, Requirements for Bases 4098-9789. 4098-9791, and 4098-9780 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current Supplied from communications Alarm Current 13 mA from separate 24 VDC supply TrueAlarm Analog Sensing Product Selection Chart Specifications