Loading...
HomeMy WebLinkAboutMAS DATA SHEETS.pdfThe new VISTA-128FBP provides the ultimate protection of life and property. This UL Listed commercial fire and burglary control panel supports up to eight partitions and up to 128 zones/points using hardwired, wireless and V-Plex® addressable technologies. A diverse line of Honeywell initiating devices, notification circuits, communication devices, keypads, RF receivers and relays are also supported. The VISTA-128FBP has been designed to mount quickly and easily in an attack resistant cabinet, and is available in 12V and 24V models. • Eight hardwired zones standard, expandable to 120 V-Plex addressable points/zones or 128 wireless points/zones • Can control eight separate areas independently (8 partitions) • Supports commercial wireless fire and burglary devices • Stores up to 512 events • Accommodates 150 user codes and up to 250 access card holders using VISTAKEY® • Supports V-Plex addressable VISTAKEY access control (1 to 8 doors) • Two on-board notification (bell) circuits delivering 2.3A @ 12V • Automatic smoke detector sensitivity maintenance testing • Four-wire smoke reset using onboard J2 output trigger • Supports Dynamic Signaling for AlarmNet Communicators • Supports Internet and GSM alarm reporting* • Supports graphical user interfaces for burglary use • Supports 6160CR-2 multi-LED fire keypad • Listed to UL864 9th Edition • Upload/download via Ethernet* • Carbon monoxide (CO) zone support * When used with AlarmNet devices. FEATURES VISTA®-128FBP/V128FBP-24 COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL Now UL864 9th Edition Approved VISTA®-128FBP/V128FBP-24 COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL ADDITIONAL FEATURES •Notification Appliance Circuits (two): - Programmable -Temporal code compliant - Individually silenceable •Programmable on-board auxiliary relay •False alarm reduction features: - Exit error logic - Exit delay reset - Cross zoning - Call waiting defeat - Recent close report •Supports commercial hardwired, addressable V-Plex®polling loop and wireless zones •Hardwired zones - Provides eight style B hardwired zones - EOLR supervised for Fire and UL burglary installations- Supports N.O. or N.C sensors - Individually assignable to any of eight partitions - Up to 16 two-wire smoke detectors each on zone one and two (32 total) - Up to 50 two-wire glassbreak detectors on zone eight • Patented addressable V-Plex polling loop technology -Supports 120 two-wire zones points -Global polling technology for faster processing -Supervised by panel - Zones individually assignable to partitions, notification circuit (bell) output or auxiliary relay -4,000 ft. capability without the use of shielded cable -Extender/Isolation bus modules -Eight zone - Class A and B expander module - Eight zone - Class B expander module -Single-zone supervised contact module • UL Listed wireless expansion - Supports up to 128 wireless zones/points -Supervised by control for check-in signals -Tamper protection for transmitters -Individually assignable up to eight partitions -Supports commercial wireless smoke detectors • Up to eight doors using VISTAKEY V-Plex Access Control • Event reporting • Local printer for event log printing • Communication -Phone line, GSM and IP communicator support -Panel operation during download Applications The VISTA-128FBP control is well suited for a variety of applications as an integrated fire and burglary control. Some of the applications supported are: medical and professional buildings, churches or synagogues, office buildings, schools, strip malls, larger residences and factory or warehouse environments. Electrical • Primary power: 18VAC @ 72VA Honeywell No. 1451 • Control panel quiescent current draw: 300mA • Backup battery: - 12VDC, 12AH min to 34.4AH max - Lead acid battery (gel type) •Alarm power: 12VDC, 1.7A max for each notification (bell) circuit output Total 2.3A 12V •Aux. standby pwr: 12VDC, 1A max •Total power: 2.3A at 12VDC •Standby time: 24 hours with 1A standby load using 34.4AH battery •Fusing: Battery input, aux. and notification (bell) circuit outputs are protected using PTC circuit protectors. All outputs are power limited. • Optional 24-volt kit Main Dialer •Line seize: Double Pole •Ringer equiv: 0.7B •Formats: ADEMCO®Low Speed, ADEMCO 4+2 Express, ADEMCO High Speed, ADEMCO Contact ID, Sescoa and Radionics Backup Communication •Dual phone line capability using 5140DLM module •AlarmNet®GSM, i-GSM and IP Communicators Cabinet Dimensions • 18" H x 14.5" W x 4.3"D Environmental • Storage temp: 14° F to 158° F (-10° C to 70° C) •Operating temp: 32° F to 122° F (0° C to 50° C) •Humidity: 85% RH •EMI: Meets or exceeds the following requirements: - FCC Part 15, Class B Device - FCC Part 68 - IEC EMC Directive Agency Listings • UL609 Grade A Local Mercantile Premises and Mercantile Safe and Vault • UL611/1610 Grades A, AA, Central Station • UL365 Grades A, AA Police Connect • UL864/NFPA72 Local, Central Station and Remote Station • UL985 • Factory Mutual • California State Fire Marshal • MEA • CAN/ULC S304 – Central and Monitoring Station Burglar Alarm Unit • CAN/ULC S527 – Central Unit for Fire Alarm Systems • CAN/ULC S303 – Local Burglar Alarm Unit • CAN/ULC S525 – Audible Signal Appliances SPECIFICATIONS COMPATIBLE DEVICES L/VSTA128FBPD/D September 2012 © 2012 Honeywell International Inc. ORDERING V128FBP-9 Commercial Fire and Partitioned Burglary Alarm Control Panel 12V Model V128FBP9-24 Commercial Fire and Partitioned Burglary Alarm Control Panel 24V Model VISTA®-128FBP/V128FBP-24 COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL Auxiliary Devices •6160CR-2 - Red Fire Keypad •6160 - Burglary Keypad •4204 - Relay Module, four form C contacts •4204CF - Two supervised output circuits •5881 Series RF receiver •5883H RF receiver •6220S - System printer used with 4100SM serial module Two-Wire Smoke Detectors Conventional •System Sensor •ESL •DSC Horn/Strobes •System Sensor •Wheelock •Gentex Manual Pull Stations • 5140MPS-1 • 5140MPS-2 V-Plex (Addressable) Devices • 4208U Universal Eight-zone Expansion Module • 4101SN Single Relay/Zone Module • 4208SNF Class A/B Expander Module • 4190SN Remote Point Module - two zones • 4193SN and 4193SNP Two-zone Expander Modules V-Plex Extender/Isolation Modules • 4297 Extender/Isolator Module • VSI Isolator Module V-Plex Smoke Detectors • 5193SD • 5193SDT V-Plex Passive Infrared Detectors • 998MX • IS2500SN • DT7500SN V-Plex (Addressable) Contacts • 4939SN-WH • 4944SN-WH • 4959SN V-Plex Glassbreak Detectors • FG1625SN Optional 24V Kit •Order number: V128FBP924KT Commercial Wireless Devices •5808W3 - Photoelectric Smoke/Heat Detector •5806W3 - Photoelectric Smoke Detector •5809 - Wireless Heat Detector •5817CB - Wireless Commercial Transmitter •5869 - Hold-Up Transmitter •5881ENHC - RF Receiver •5883H - RF Receiver Access Control •VISTAKEY®V-Plex (addressable) Access Control •VISTAKEY-SK Starter Kit •VISTAKEY-EX Expansion Kit Alarm Communications •7845i-ENT - Internet/Intranet Communicator •7845GSM - Digital Cellular Communicator •7845i-GSM - Internet and Digital Cellular Communicator •GSMCF/iGSMCF - Commercial Fire Communication Kits (when available) •IPGSM-DP Internet and Digital Cellular Communicator For more information: www.honeywell.com/security Automation and Control Solutions Honeywell Security Products Americas 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 1.800.467.5875 www.honeywell.com Product specifications subject to change. 6160 ALPHA DISPLAY KEYPAD CO06010 L/6160/D September 2006 © 2006 Honeywell International Inc. Honeywell Security & Custom Electronics Honeywell International Inc. PO Box 9035 Syosset, NY 11791 www.honeywell.com ORDERING 6160 Alpha Display Keypad The 6160 Deluxe Keypad is easy to install and simple to use. The attractive white console blends with any décor and features a contoured, removable door that conceals illuminated soft-touch keys. The 6160 also features a new larger and brighter 32-character display with easy-to-read plain-English status messages. The oversized function keys are easily accessed even when the keypad door is closed, and can be programmed for fire, burglary, personal emergencies and other operations. Colored self-adhesive labels are included. • Large, easy-to-use keypad • Keys continuously backlit for greater visibility • Speaker with audible beeps to indicate: - System status - Entry/exit delay - Other alarm situations • Zones and system events displayed in plain English • No confusing blinking lights • Four programmable function keys • System functions clearly labeled • Functions performed by just entering security code plus command • White with removable door blends with any décor FEATURES Physical • 5-5/16"H x 7-3/8"W x 1-3/16"D (135mm x 190mm x 30mm) Current • Standby-40mA • Activated Transmission-160mA Wiring • - (Black): Ground • + (Red): +12 VDC (Aux. Power) • D1 (Green):“Data in” to control panel • D0 (Yellow):“Data out” from control panel Compatibility • Fully compatible with all VISTA controls. SPECIFICATIONS WITH DOOR ATTACHED WITHOUT DOOR Honeywell’s 5193SD/SDT Addressable Photoelectric Smoke Detector is designed to provide open area protection and to be used with compatible UL-listed Honeywell control panels that support V-Plex technology. The detector incorporates a state-of-the-art optical sensing chamber and an advanced microprocessor. Built-in Drift Compensation algorithms automatically maintain proper operation at factory calibrated detection levels, even when sensitivity is altered due to the presence of contaminates settling into the unit’s chamber. The 5193SDT also features a restorable, built-in, fixed temperature (135° F/57.2° C) thermal detector. • Easy Installation:Installation of the 5193SD/SDT detector is simplified by the use of a mounting base that may be pre-wired to the system, allowing the detector to be easily installed or removed for maintenance or service. (See Figure 1). • LED Status Indicators:Two LEDs (green and red) provide local visual indication of the detector’s status – including normal operation, alarm, out of sensitivity and trouble conditions. • Test button:This button allows the user to perform periodic testing of the detector’s circuitry and verify that the detector is within the sensitivity limits. • Versatile Mounting:Mounting is made simple with the included hardware and the large mounting ports, which accommodate drywall anchors for easy surface mounting. (See Figure 1). • Tamper Protection and Tamper Resistance:The detector contains a built-in tamper switch that can communicate back to the control panel in the event the detector is removed from its base. For an added level of security, the detector also includes a tamper resistant element that prevents removal from the base without the use of tools. (See Figure 1). FEATURES 5193SD/5193SDT V-PLEX®ADDRESSABLE SMOKE DETECTOR Figure 1: Tamper-Resistant Feature/Wiring SNAP OFF TAB FOR TAMPER LOCK TAMPER RELEASE TAB DIRECT MOUNT HOLES L/5193SDT/D May 2009 © 2009 Honeywell International Inc. Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 www.honeywell.com ORDERING 5193SD Addressable Photoelectric Smoke Detector 5193SDT Addressable Photoelectric Smoke Detector with Integral Heat Sensor Accessory sold separately: SENS-RDR Handheld Sensitivity Reader SPECIFICATIONS 5193SD/5193SDT V-PLEX®ADDRESSABLE SMOKE DETECTOR • Heat Sensor:(Model 5193SDT): 135° F (57.2° C); Fixed Temperature Electronic Thermistors • Operating Ambient Temperature Range: 32° to 100° F (0° to 38° C) • Operating Humidity Range: 0 to 95% RH non-condensing • Storage Temperature Range: -4° to 158° F (-20° to 70°C) • Diameter (including base):5.3 inches • Height (including base):2.0 inches • Weight:6.3 oz. • Agency Listing:UL-268 • System Voltage Range:7-14V • Standby Current (maximum @ 12V) LED off: 1.2mA LED on: 2.8mA To measure the detector’s sensitivity, the SENS-RDR Infrared Sensitivity Reader tool (sold separately) should be used. It reduces testing time, simplifies sensitivity measurements and displays them precisely in terms of percent per foot obscuration. The SENS-RDR eliminates the need for magnets, voltmeters and ladders. ACCESSORY (sold separately) Figure 2: Position of Reader OR 5800CO CARBON MONOXIDE DETECTOR WITH BUILT-IN WIRELESS TRANSMITTER The 5800CO is a 3V battery powered wireless carbon monoxide (CO) detector intended for use with Honeywell alarm systems that support 5800 Series wireless devices. It provides early warning when its electrochemical sensing technology measures carbon monoxide levels in the air. The 5800CO is specifically designed for system operation and is fully listed to UL 2075 as a system supervised detector.* It contains a piezoelectric horn which generates the ANSI S3.41 temporal 4 pattern in an alarm condition. The detector consists of an electrochemical carbon monoxide sensor assembly coupled with a wireless transmitter. The transmitter can send alarm, trouble, end-of-life, tamper and low battery condition messages to the alarm panel. Since there are no holes to drill or wires to run, you can preserve the beauty of the home or building while protecting its occupants from harmful carbon monoxide gas. The 5800CO is an ideal carbon monoxide detector for difficult to wire locations, applications where room aesthetics are critical or where hazardous materials exist. What is Carbon Monoxide and How Can it Harm Consumers? Carbon monoxide (CO) is an odorless, colorless, tasteless and highly toxic gas that is produced when fuels such as wood, gasoline, charcoal and oil are burned with insufficient air. The majority of residential and commercial fatalities caused from these fuels come from heating systems, engine powered tools and charcoal grills. Carbon monoxide is harmful when inhaled because it displaces oxygen in the blood and deprives the heart, brain and other vital organs of oxygen. Large amounts of CO can overcome a person in minutes without warning—causing them to lose consciousness and suffocate. The 5800CO is designed to warn the end-user well before the CO reaches a fatal level. The detector’s CO sensitivity is evaluated to UL 2034. CO Concentration Min. Time to Alarm Max. Time to Alarm 30 ppm +/- 5 ppm 30 days Indefinite** 70 ppm +/- 5 ppm 60 minutes 240 minutes 150 ppm+/- 5 ppm 10 minutes 50 minutes 400 ppm+/- 5 ppm 4 minutes 15 minutes CO Levels and Time to Alarm *For a complete list of products that support system operation of the 5800CO to UL standard 2075, please visit: www.honeywell.com/security/hsc/resources/agency/co **Life of product Electrochemical Sensing Technology - Electrochemical detectors are the newest, most refined CO detectors available and provide the most accurate measurement of CO concentration obtainable. They can take readings from low levels that may be hazardous over long periods of time to high concentrations that present an immediate danger. Local Sounder - A built-in piezoelectric horn generates the ANSI S3.41 temporal 4 pattern in an alarm condition. The local sounder will also alert the end-user of other conditions such as low battery, detector trouble and end-of-life. LED Status Indicators - Dual LEDs provide local visual indication of the detector’s status–including normal operation, alarm, low battery, trouble and end-of-life (see figure 1). End of Life Timer - When the detector has reached the end of its life, the detector will send a trouble signal to the panel. This indicates that the CO sensor inside the detector has passed the end of its life and the detector needs to be replaced. The detector’s lifespan is approximately six years from the date of manufacture. Full Supervision - The 5800CO is fully supervised to monitor for low battery, case tamper and trouble conditions. Test/Hush Button - This dual purpose button allows the end-user to perform periodic testing of the detector. In the event of a CO alarm, this button will silence the local sounder alarm for a five minute period. Note: the Hush feature will not operate at levels above 350 ppm (parts per million) carbon monoxide (see figure 1). Versatile Mounting - Whether you choose to affix the detector to the ceiling or a wall, mounting is made simple with the enclosed hardware. The mounting base has large mounting ports, which accommodate drywall anchors for easy surface mounting (see figure 2). Tamper Protection and Tamper Resistant Element - The detector has a built-in tamper switch that can communicate back to the control panel in the event it is removed from the base. For an added level of security, the detector also includes a tamper resistant element that prevents removal from the base without the use of a tool (see figure 2). 5800CO CARBON MONOXIDE DETECTOR WITH BUILT-IN WIRELESS TRANSMITTER KEY FEATURES Figure 1 Figure 2 5800CO CARBON MONOXIDE DETECTOR WITH BUILT-IN WIRELESS TRANSMITTER MOUNTING RECOMMENDATIONS CO is slightly lighter than air and when heated by a fuel-burning source, the lighter weight and warm temperature of the CO causes it to quickly rise to the ceiling and mix freely with the air. Check with the local Authority Having Jurisdiction (AHJ) for CO detector requirements in your area. Some recommendations for installing the 5800CO are as follows: - On every floor of the facility - Inside any areas that contain a fuel-burning appliance - In the vicinity of flame-fueled appliances, but no closer than 10 feet • For wall mount - The detector should be at least as high as a light switch and at least six inches from the ceiling • For ceiling mount - The detector should be at least 12 inches from any wall SPECIFICATIONS • Power Source: One 3V CR123A lithium battery (included) • Audible Signal (temporal 4 tone):85 dB in alarm (at 10 ft.) • Height:2.3" (58mm) • Diameter:5.3" (135mm) with mounting base • Weight:7 oz. (241 g) without battery • Operating Ambient Temperature Range:32° F to 100° F (0° C to 37.8° C) • Operating Humidity Range:15% to 95% relative humidity, non-condensing • Agency Listings: -Listed to UL standard 2075, *CO sensitivity is evaluated to UL 2034 -5800COA ULC Listed - tested to the CAN/CSA 6.19.01 standard *For a complete list of products that support system operation of the 5800CO to UL standard 2075 and 5800COA ULC standard, please visit: www.honeywell.com/security/hsc/resources/agency/co ORDERING 5800CO Wireless Carbon Monoxide Detector with Built-in Wireless Transmitter 5800COA Wireless Carbon Monoxide Detector with Built-in Wireless Transmitter with ULC listing L/5800COD/D March 2009 © 2009 Honeywell International Inc. Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 www.honeywell.com FEATURES 5806W3 WIRELESS PHOTOELECTRIC SMOKE DETECTOR Honeywell’s 5806W3 is a 3V battery operated, photoelectronic smoke detector with a built-in wireless transmitter. It facilitates fire verification for false alarm reduction requirements by ANSI/SIA CP-01standards and is intended for use with any of Honeywell’s 5800 Series wireless receiver/transceivers for residential installations. The 5881ENHC or 5883H receivers are required for commercial installations. The transmitter can send alarm, tamper, maintenance (when control panels are equipped to process maintenance signals) and battery condition messages to the system’s receiver. The maintenance signal fully complies with the sensitivity test requirement specified in NFPA 72, 7-2.2 and is UL approved. The 5806W3 incorporates a state-of-the-art optical sensing chamber and advanced microprocessor. It also helps eliminate nuisance alarms and virtually eliminates non-billable service calls and fines resulting from false alarms. The microprocessor allows the detector to automatically maintain proper operation at factory calibrated detection levels, even when sensitivity is altered due to the presence of contaminants settling into the unit’s smoke chamber. A removable detector cover and chamber top allows the technician to quickly and easily clean the detector chamber without disassembling the detector head. Since there are no holes to drill or wires to run, installers can preserve the beauty of the protected premise while protecting it. The 5806W3 is an ideal smoke detector for difficult to wire locations, applications where room aesthetics are critical or where hazardous materials exist. • Smoothing Algorithms Mathematical calculations in the detector’s software that minimize nuisance alarms by smoothing out short term spikes from dust and smoke. • Smart Check A signal is sent to the control panel when the detector requires cleaning. This allows a regular, non-emergency service call to clean the detector before it goes into alarm. • Drift Compensation Virtually eliminates nuisance alarms from long-term dust build-up by automatically adjusting the detector’s sensitivity. • Removable Detector Cover and Chamber Top Provides the technician the ability to quickly and easily clean the detector chamber without disassembling the detector head. • Approved UL Listings for Residential and Commercial Applications Both residential and commercial installation requirements are met. • Additional LED Status Indicators Identifying between alarm or trouble conditions is easier with green and red LED status indicators. The green LED denotes a normal condition while the red LED indicates an abnormal condition. • Easy-to-install Mounting Base The sturdy mounting base allows the detector to be more easily installed on uneven surfaces (i.e. stucco). The mounting base has larger mounting ports to accommodate drywall anchors for easy surface mounting. • Improved Robust RF Field Strength The distance between the detector and receiver has been significantly increased. Additional Features: • Utilizes one long-life 3V lithium battery • Microcontroller runs on an 4.0 MHz clock • Horn operates at 3.3 KHz with sound pressure level of 85dBA at 10 feet • Built-in wireless transmitter, temporal code 3 sounder ORDERING 5806W3 Wireless Photoelectric Smoke Detector with Built-in Wireless Transmitter Accessories sold separately: SENS-RDR Hand-held Sensitivity Reader RT i3 Removal Tool used for easy installation and removal of head from base Honeywell Security & Communications Honeywell 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 www.honeywell.com L/5806W3DS/D February 2008 © 2008 Honeywell International Inc. 5806W3 WIRELESS PHOTOELECTRIC SMOKE DETECTOR SPECIFICATIONS ACCESSORIES (sold separately) • Dimensions – Diameter: 5.3"*, Height: 2.30" • Weight – 8.5 oz. (without batteries) • Operating Temperature – 32–100°F (0–37.8°C) • Humidity Range – 0% to 95% RH, non-condensing • Air Velocity – 1,000 ft./min. max. • Operating Voltage – 2.5–3.6VDC • Standby Current – 8.5 µA avg. • Alarm Current – 35 mA max. • Power Source – One 3V CR123A lithium Battery† • Audible Output – 85dB min. @ 10 ft. • Agency Listings – UL268 – Commercial and Residential SENS-RDR Infrared Sensitivity Reader Reduces testing time, simplifies sensitivity measurements and displays them precisely in terms of percent per foot obscuration. The SENS-RDR eliminates the need for magnets, voltmeters and ladders. RT Removal Tool Simplifies the attachment and removal of the detector head to the mounting base. It may be attached to a threaded extension pole or broom handle thereby eliminating the need for ladders. * With adapter bracket (4.9" without mounting base) †Replacement batteries include Duracell DL123A, Sanyo CR123A, Panasonic CR123A, or ADEMCO 466 Agency Listings Mini-Horns The SpectrAlert® Advance series of mini-horn sounders are designed to simplify installations to provide primary and secondary signaling for fire and security applications. Features • 12 and 24V operation • High and low volume settings • Temporal and non-temporal tones • Mounts to single gang back box • Compatible with MDL sync module • Mechanically and electrically compatible with PA400 series Mini-Alert™ sounders • Listing for ceiling or wall mounting The MHR and MHW mini-horns operate at 12 and 24 volts and are ideal for hotel, motel or residential fire system applications, where a smaller notification device is desired. The mini-horns offer high and low volume settings, and temporal or non-temporal tones. The horns can be mounted to single gang back boxes for aesthetically sensitive applications. Synchronization is also provided when using the MDL module. The MHR and MHW mini-horns can operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified, unfiltered power supply. They are listed to Underwriter’s Laboratories Standard UL 464 for fire protective signaling systems. S4011 3028007 CS1099 7135-1653:196 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2012 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS01500 • 3/12 Ordering Information Part No.Description MHR Mini-Horn, Red MHW Mini-Horn, White SpectrAlert® Advance Mini-Horn Specifications Architectural/Engineering Specifications Mini-horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a deep single gang back box. Mini-horn shall be listed to Underwriter’s Laboratories Standard UL464 for fire protective signaling systems. Mini-horns shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full-wave rectified, unfiltered power supply. When used with the Sync•Circuit™ Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Physical Specifications Dimensions 4.6˝L × 2.9˝W × .45˝D Weight 2.67 oz. Operating Temperature Range 32°F to 120°F (0°C to 49°C) Mounting Surface: deep single-gang back box (23/4˝ deep) Flush: Standard 4˝ × 4˝ back box with single gang mud ring, which allows sufficient clearance for conduit entrance. Electrical Specifications Input Terminals 12 to 18 AWG Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR Operating Voltage 8–33 Operating Voltage with MDL 9–33 UL Sound Output and Current Draw Data Sounder Output (dBA) Switch Setting Pattern Output Level 8–17.5 VDC 8–17.5 VFWR Nominal 12 VDC Nominal 12 VFWR 16–33 VDC 16–33 VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non- temporal High 72 71 75 74 80 79 4 Non- temporal Low 70 69 73 72 78 77 Sounder Current Draw (mA RMS) Switch Position Sound Pattern Volume 8–17.5 Volts 16–33 Volts DC FWR DC FWR 1 Temporal High 12 10 17 15 2 Temporal Low 10 9 14 13 3 Non-temporal High 22 17 29 25 4 Non-temporal Low 17 13 21 19